Loading...
HomeMy WebLinkAboutEnergy Efficiency Codet FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot 59 Block 1 Waterstone 2020 BGL Builder Name: ADAMS HOMES Street: 8709 Marano Avenue Permit Office: City, State, Zip: Fort Pierce , FL , 34951 Permit Number: Owner: Jurisdiction: 661000 Design Location: FL, ST_LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type�1829.9 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1429.50 ft2 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent c. Frame - Wood, Exterior R=13.0 317.53 ft2 R=13.0 82.83 ft2 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Types (2100.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 2020.00 ft2 6. Conditioned floor area above grade (ft2) 2020 b. Knee Wall (Vented) R=19.0 80.00 ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(202.3 sqft.) Description Area 12. Ducts R ft2 a. U-Factor: Dbl, U=0.33 147.17 ft2 a. Sup: Attic, Ret: Main, AH: Main 6 404 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 32.38 ft2 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 35.0 SEER:16.00 c. U-Factor: Dbl, U=0.55 17.78 ft2 SHGC: SHang D0 Area Weighted Average Overhang Depth: 3.216 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.270 a. Electric Heat Pump 34.6 HSPF:8.50 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 40 gallons 9. Floor Types (2020.0 sqft.) Insulation Area EF: 0.940 a. Slab -On -Grade Edge Insulation R=0.0 2020.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 16. Credits Pstat Total Proposed Modified Loads: 61.44 Glass/Floor Area: 0.100 PASS Total Baseline Loads: 62.43 I hereby certify that the plans a p ations covered b w eof the plans andTKB ST'4?' this calculation are in com li c the Florid P ov specifications covered b this P y '�" _ Code. calculation indicates compliance , �e� ! �i,,��'Ot� with the Florida EnergyCode. PREPARED BY: Before construction is completed 0 DATE: 117-16-201 Winn KanmanY this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. , with the FloridaG'pD•.:�¢�y OWNER/AG BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).®�� FILE, 7/16/2021 9:27 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 4 T FORM R405-2020 INPUT SUMMARY CHFCKI IST RFPC)RT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: Lot 59 Block 1 Waterstone 20 Bedrooms: 4 User Conditioned Area: 2020 Total Stories: 1 1 Worst Case: No ADAMS HOMES Rotate Angle: 0 Cross Ventilation: No 661000 Whole House Fan: No Detached New (From Plans) Address Type: Lot # Block/Subdivision: PlatBook: Street: County: City, State, Zip: Lot Information 59-1 Waterstone 8709 Merano Avenue St. Lucie Fort Pierce , FL , 34951 CLIMATE / V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Blockl 2020 21210 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 2020 21210 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 162 ft 0 2020 ft2 ---- 0.37 0 0.63 ROOF / V # Type Roof Gable Roof Materials Area Area Color Rad Solar SA Emitt Barr Absor. Tested Emitt Deck Pitch Tested Insul. (deg) 1 Gable or Shed Composition shingles 2259 ft2 506 ft2 Medium N 0.85 N 0.85 No 0 26.57 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 2020 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 2 Under Attic (Vented) Knee Wall (Vented) Main 30 Blown Main 19 Batt 2020 ft2 0.11 80 ft2 0.11 Wood Wood 7/16/2021 9:27 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 4 FORM R405-2020 INPI IT GI IMMARV P_1-Ir:rk-1 14ZT 0C0n0T WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 0 1 E Exterior Concrete Block - Int Insul Main 4.1 45 6 9 4 424.7 ftz 0 0 0.6 0 2 N Exterior Concrete Block - Int Insul Main 4.1 8 0 11 10 94.7 ftZ 0 0 0.6 0 3 W Exterior Concrete Block - Int Insul Main 4.1 46 2 11 10 546.3 ftZ 0 0 0.6 0 4 S Exterior Concrete Block - Int Insul Main 4.1 30 9 11 10 363.9 ftZ 0 0 0.6 0 5 - Garage Frame - Wood Main 13 26 10 11 10 317.5 ftZ 0 0.23 0.01 0 6 N Exterior Frame - Wood Main 13 7 11 10 82.8 ftz 0.23 0.6 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N Insulated Main None .25 3 6 8 20 ftZ 2 Wood Main None .25 2 8 6 8 17.8 ftZ WINDOWS Orientation shown is the entered, Proposed orientation. V Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 E 1 Vinyl Low-E Double Yes 0.33 0.23 N 48.6 ftz 1 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 2 N 6 Vinyl Low-E Double Yes 0.33 0.31 N 5.0 ft' 6 ft 0 in 1 ft 6 in None None 3 N 2 Vinyl Low-E Double Yes 0.33 0.21 N 32.4 ftz 1 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 4 W 3 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ftz 1 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 5 S 4 Metal Low-E Double Yes 0.55 0.7 N 17.8 ftz 11 ft 4 in 1 ft 0 in None None 6 S 4 Vinyl Low-E Double Yes 0.33 0.23 N 10.7 ftz 1 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 7 S 4 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ftz 1 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 8 S 4 Vinyl Low-E Double Yes 0.33 0.23 N 23.2 ftz 11 ft 4 in 0 ft 6 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 593 ftz 593 ftz 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000467 2474.5 135.76 254.87 .1409 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ None Singl HSPF:8.5 34.6 kBtu/hr 1 sys#1 7/16/2021 9:27 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4 FORM R405-2020 INPl1T Sl1MMARY rl-IFrKI IRT RFPnRT COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 16 35 kBtu/hr cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ftz DUCTS ---- Supply ---- ---- Return ---- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 404 ftz Main 101 ft' Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Coolingj Jan j Feb HeatinX] Jan X] Feb Mar � Mar A r APr Jul May Jun Jul May rj Junrl Au Auf rl X Se Sep Oct Oct Nov Nov Dec Dec Ventin [ ] Jan [ j Feb X Mar A r [ Ma Jun Jul Aug [ Se [X] Oct X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 .68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ftZ 0 ft 0.3 Main 7/16/2021 9:27 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4 4 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ftZ) 7. Windows- Description a. U-Factor: Dbl, U=0.33 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 SHGC: SHGC=0.21 c. U-Factor: Dbl, U=0.55 SHGC: SHGC=0.70 d. U-Factor: other (see details) SHGC: other (see details) Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Skylights Description a. U-Factor(AVG): N/A SHGC(AVG): N/A 8709 Merano Avenue, Fort Pierce, FL, 34951 New (From Plans) 10. Wall Type and Insulation Detached a. Concrete Block - Int Insul, Exterior b. Frame - Wood, Adjacent 1 c. Frame - Wood, Exterior 4 d. N/A No 11. Ceiling Type and insulation level a. Under Attic (Vented) 2020 b. Knee Wall (Vented) Area c. N/A 147.17 ftZ 12. Ducts, location & insulation level a. Sup: Attic, Ret: Main, AH: Main 32.38 ftZ 13. Cooling systems 17.78 ftZ a. Central Unit 5.00 ftZ 3.216 ft. 0.270 Area ftZ 9. Floor Types Insulation Area a. Slab -On -Grade Edge Insulation R=0.0 2020.00 ftZ b. N/A R= ftZ c. N/A R= ftZ 14. Heating systems a. Electric Heat Pump 15. Hot water systems a. Electric b. Conservation features None Credits (Performance method) I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: Address of New Home: City/FL Zip: Insulation Area R=4.1 1429.50 ftZ R=13.0 317.53 ftZ R=13.0 82.83 ftZ R= ftZ Insulation Area R=30.0 2020.00 ftZ R=19.0 80.00 ftZ R= ftZ R ftZ 6 404 kBtu/hr Efficiency 35.0 SEER:16.00 kBtu/hr Efficiency 34.6 HSPF:8.50 Cap: 40 gallons EF: 0.94 Pstat *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 7/16/2021 9:27 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1