Loading...
HomeMy WebLinkAboutEnergy Efficiency Code,,ol' r_lp "aR$651 FORM R405-2020 Department FLORIDA ENERGY EFFICIENCY CODE FORpe9Wt1JYNG CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot 33 Phase 3 Waterstone CRGR Builder Name: ADAMS HOMES Street: 8694 Waterstne Boulevard Permit Office: City, State, Zip: Fort Pierce , FL , 34951 Permit Number: Owner: Jurisdiction: 661000 Design Location: FL, ST_LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type> 202O.7 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1748.70 ft2 b. Frame - Wood, Adjacent R=13.0 272.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Types (2643.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 2523.00 ft2 6. Conditioned floor area above grade (ft2) 2523 b. Knee Wall (Vented) R=19.0 120.00 ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(293.4 sqft.) Description Area 12. Ducts R ft2 a. Sup: Attic, Ret: Main, AH: Main 6 503.2 a. U-Factor: Dbl, U=0.33 166.06 ft2 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 70.92 ft2 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 42.0 SEER:15.00 c. U-Factor: Dbl, U=0.55 35.56 ft2 SHGC: SHGC=0.70 Area Weighted Average Overhang Depth: 6.223 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.288 a. Electric Heat Pump 42.0 HSPF:8.50 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 40 gallons 9. Floor Types (2523.0 sqft.) Insulation Area EF: 0.940 a. Slab -On -Grade Edge Insulation R=0.0 2523.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 16. Credits Pstat Total Proposed Modified Loads: 70.96 Glass/Floor Area: 0.116 PASS Total Baseline Loads: 71.81 I hereby certify that the plans I iications covere ' Rev w of the plans and O-evv Spg this calculation are in comp' n o nergy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. ti rrrriO- PREPARED BY: Before construction is completed DATE: n7-90-9n91 1Afinn Kanmany this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. y with the Florida Ener y Code. �►'prj OWNER/ BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this projeres an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). CV9 - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leaky tcto ors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.060 Qn for whole house. ®�I - 7/20/2021 10:44 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 5 'FORM R405-2020 IAIPI IT CI IMIIAA0V rru=rei icr 11311=10nDr PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: Lot 33 Phase 3 Waterstone C Bedrooms: 4 User Conditioned Area: 2523 Total Stories: 1 1 Worst Case: No ADAMS HOMES Rotate Angle: 0 Cross Ventilation: No 661000 Whole House Fan: No Detached New (From Plans) Address Type: Lot # Block/Subdivision: PlatBook: Street: County: City, State, Zip: Lot Information 33 Phase 3 Waterstone 8694 Waterstne Boulev St. Lucie Fort Pierce , FL , 34951 CLIMATE / Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Blockl 2523 22202.4 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 2523 22202.4 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 208.9 ft 0 2523 ftz ---- 0.44 0 0.56 ROOF / # Type Roof Gable Roof Materials Area Area Color Rad Solar SA Emitt Barr Absor. Tested Emitt Deck Pitch Tested Insul. (deg) 1 Gable or Shed Composition shingles 2821 ftz 630 ftZ Medium N 0.85 N 0.85 No 0 26.57 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 2523 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 2 Under Attic (Vented) Knee Wall (Vented) Main 30 Blown Main 19 Batt 2523 ft2 0.11 120 ftz 0.11 Wood Wood 7/20/2021 10:44 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 5 'FORM R405-2020 INPIIT Al IMMAPV rl41=r1C1 icT MCOnOT WALLS Adjacent Space Cavity Width _AreaAhqnrGrade% Height Sheathing Framing Solar Below 1 N Exterior Concrete Block - Int Insul Main 4.1 48 6 8 0 388.0 ft2 0 0' 0.6 0 2 E Exterior Concrete Block - Int Insul Main 4.1 37 2 8 0 297.3 ft2 0 0 0.6 0 3 S Exterior Concrete Block - Int Insul Main 4.1 51 3 8 0 410.0 ft2 0 0 0.6 0 4 SW Exterior Concrete Block - Int Insul Main 4.1 6 2 8 0 49.3 ft2 0 0 0.6 0 5 W Exterior Concrete Block - Int Insul Main 4.1 37 6 8 0 300.0 ft2 0 0 0.6 0 6 - Garage Frame - Wood Main 13 34 0 8 0 272.0 ft2 0 0.23 0.01 0 7 W Exterior Concrete Block - Int Insul Main 4.1 23 6 8 0 188.0 ft2 0 0 0.6 0 8 N Exterior Concrete Block - Int Insul Main 4.1 8 6 8 0 68.0 ft2 0 0 0.6 0 9 S Exterior Concrete Block - Int Insul Main 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SW Insulated Main None .25 3 6 8 20 ft2 2 - Wood Main None .25 2 8 6 8 17.8 ft2 3 S Insulated Main None .25 2 4 6 8 15.6 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ft2 25 ft 0 in 0 ft 10 in Drapes/blinds None 2 N 1 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds Exterior 5 3 E 2 Vinyl Low-E Double Yes 0.33 0.31 N 7.5 ft2 13 ft 0 in 0 ft 6 in None None 4 E 2 Vinyl Low-E Double Yes 0.33 0.31 N 13.3 ft2 13 ft 0 in 2 ft 10 in None None 5 E 2 Vinyl Low-E Double Yes 0.33 0.21 N 32.4 ft2 7 ft 4 in 1 ft 4 in Drapes/blinds Exterior 5 6 E 2 Vinyl Low-E Double Yes 0.33 0.21 N 38.5 ft2 1 ft 4 in 2 ft 0 in Drapes/blinds Exterior 5 7 S 3 Vinyl Low-E Double Yes 0.33 0.23 N 9.8 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds Exterior 5 8 S 3 Vinyl Low-E Double Yes 0.33 0.23 N 16.2 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds Exterior 5 9 SW 4 Vinyl Low-E Double Yes 0.33 0.23 N 12.5 ft2 7 ft 2 in 0 ft 4 in Drapes/blinds Exterior 5 10 W 5 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ft2 9 ft 10 in 0 ft 10 in Drapes/blinds None 11 W 5 Vinyl Low-E Double Yes 0.33 0.23 N 16.7 ft2 7 ft 2 in 0 ft 4 in Drapes/blinds Exterior 5 12 W 7 Vinyl Low-E Double Yes 0.33 0.23 N 30.0 ft2 9 ft 10 in 0 ft 4 in Drapes/blinds Exterior 5 13 W 5 Vinyl Low-E Double Yes 0.33 0.23 N 48.6 ft2 1 ft 4 in 1 ft 2 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 620 ft2 620 ft2 64 ft 8 ft 1 7/20/2021 10:44 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 5 `FORM R405-2020 INP11T Sl1MMARY r14I=CKI IST RFPnPT INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000391 2590.3 142.11 266.8 .1312 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 42 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Sing[ SEER: 15 42 kBtu/hr cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ftz DUCTS ---- Supply ---- V # Location R-Value Area ---- Return ---- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 Attic 6 503.2 ft Main 125.8 ft Proposed Qn Main --- cfm 151.4 cfm 0.06 0.60 1 1 TEMPERATURES Programable Thermostat: Y Cooling[ Jan Feb Mar Heatin[X} Jan f X� Feb Mar Ventin [ ]Jan [ Feb X Mar Ceiling Fans: Jul X Aug Se f APr f May f Jun Julf Au4 SeP Apr Ma X Jun ri [X] A r [ Ma [ Jun Jul [ Aug [ Se [X] Oct Nov Oct Nov Oct X Nov Dec Dec Dec 7/20/2021 10:44 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 5 "FORM R405-2020 INPUT SUMMARY rl-IFrKi i-CZT 92FOnOT Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM PM 66 66 66 66 66 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 lbs/s .ft. 0 ft2 0 ft 0.3 Main 7/20/2021 10:44 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 5 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the EnergyPerformance Index, the more efficient the home. 8694 Waterstne Boulevard, Fort Pierce, FL, 34951 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1748.70 ftZ b. Frame - Wood, Adjacent R=13.0 272.00 ftZ 3. Number of units, if multiple family 1 c. N/A R= ftZ 4. Number of Bedrooms 4 d. N/A R= ftZ 5. Is this a worst case? No 11. Ceiling Type and insulation level Insulation Area a. Under Attic (Vented) R=30.0 2523.00 ftZ 6. Conditioned floor area (ftZ) 2523 b. Knee Wall (Vented) R=19.0 120.00 ftZ 7. Windows" Description Area c. N/A R= ftZ a. U-Factor: Dbl, U=0.33 166.06 ftZ 12. Ducts, location & insulation level R ftZ a. Sup: Attic, Ret: Main, AH: Main 6 503.2 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 70.92 ftZ SHGC: SHGC=0.21 13. Cooling systems kBtu/hr Efficiency c. U-Factor: Dbl, U=0.55 35.56 ftZ a. Central Unit 42.0 SEER:15.00 SHGC: SHGC=0.70 d. U-Factor: other (see details) 20.83 ftZ SHGC: other (see details) 14. Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 6.223 ft. a. Electric Heat Pump 42.0 HSPF:8.50 Area Weighted Average SHGC: 0.288 8. Skylights Description Area 15. Hot water systems a. U-Factor(AVG): N/A Z ft a. Electric Cap: 40 gallons SHGC(AVG): N/A EF:0.94 b. Conservation features 9. Floor Types Insulation Area None a. Slab -On -Grade Edge Insulation R=0.0 2523.00 ftZ Credits (Performance method) Pstat b. N/A R= ftZ c. N/A R= ftZ I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: Address of New Home: City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 7/20/2021 10:45 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1