HomeMy WebLinkAboutEnergy Efficiency Code,,ol' r_lp
"aR$651
FORM R405-2020 Department
FLORIDA ENERGY EFFICIENCY CODE FORpe9Wt1JYNG CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Lot 33 Phase 3 Waterstone CRGR
Builder Name: ADAMS HOMES
Street: 8694 Waterstne Boulevard
Permit Office:
City, State, Zip: Fort Pierce , FL , 34951
Permit Number:
Owner:
Jurisdiction: 661000
Design Location: FL, ST_LUCIE_CO_INTL
County: St. Lucie (Florida Climate
Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Type> 202O.7 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1748.70 ft2
b. Frame - Wood, Adjacent
R=13.0 272.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 4
d. N/A
R= ft2
5. Is this a worst case? No
11. Ceiling Types (2643.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 2523.00 ft2
6. Conditioned floor area above grade (ft2) 2523
b. Knee Wall (Vented)
R=19.0 120.00 ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
7. Windows(293.4 sqft.) Description Area
12. Ducts
R ft2
a. Sup: Attic, Ret: Main, AH: Main
6 503.2
a. U-Factor: Dbl, U=0.33 166.06 ft2
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33 70.92 ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
42.0 SEER:15.00
c. U-Factor: Dbl, U=0.55 35.56 ft2
SHGC: SHGC=0.70
Area Weighted Average Overhang Depth: 6.223 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.288
a. Electric Heat Pump
42.0 HSPF:8.50
8. Skylights Area
c. U-Factor:(AVG) N/A ft2
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 40 gallons
9. Floor Types (2523.0 sqft.) Insulation Area
EF: 0.940
a. Slab -On -Grade Edge Insulation R=0.0 2523.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
16. Credits
Pstat
Total Proposed Modified Loads: 70.96
Glass/Floor Area: 0.116
PASS
Total Baseline Loads: 71.81
I hereby certify that the plans I iications covere
'
Rev w of the plans and
O-evv Spg
this calculation are in comp' n o nergy
specifications covered by this
Code.
calculation indicates compliance
with the Florida Energy Code.
ti rrrriO-
PREPARED BY:
Before construction is completed
DATE: n7-90-9n91 1Afinn Kanmany
this building will be inspected for
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
y
with the Florida Ener y Code.
�►'prj
OWNER/
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this projeres an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). CV9
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leaky tcto ors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.060 Qn for whole house. ®�I -
7/20/2021 10:44 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 5
'FORM R405-2020 IAIPI IT CI IMIIAA0V rru=rei icr 11311=10nDr
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
Lot 33 Phase 3 Waterstone C Bedrooms: 4
User Conditioned Area: 2523
Total Stories: 1
1 Worst Case: No
ADAMS HOMES Rotate Angle: 0
Cross Ventilation: No
661000 Whole House Fan: No
Detached
New (From Plans)
Address Type:
Lot #
Block/Subdivision:
PlatBook:
Street:
County:
City, State, Zip:
Lot Information
33 Phase 3
Waterstone
8694 Waterstne Boulev
St. Lucie
Fort Pierce ,
FL , 34951
CLIMATE
/
Design
Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70 75 299
58 Medium
BLOCKS
Number
Name
Area Volume
1
Blockl
2523 22202.4
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
2523 22202.4 Yes 5
4 1 Yes
Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 208.9 ft 0
2523 ftz ----
0.44 0 0.56
ROOF
/
#
Type
Roof Gable Roof
Materials Area Area Color
Rad Solar SA Emitt
Barr Absor. Tested
Emitt Deck Pitch
Tested Insul. (deg)
1
Gable or Shed Composition shingles 2821 ftz 630 ftZ Medium
N 0.85 N 0.85
No 0 26.57
ATTIC
/
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 2523 ft' N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
2
Under Attic (Vented)
Knee Wall (Vented)
Main 30 Blown
Main 19 Batt
2523 ft2 0.11
120 ftz 0.11
Wood
Wood
7/20/2021 10:44 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 5
'FORM R405-2020 INPIIT Al IMMAPV rl41=r1C1 icT MCOnOT
WALLS
Adjacent
Space
Cavity Width
_AreaAhqnrGrade%
Height
Sheathing Framing Solar Below
1 N
Exterior
Concrete Block - Int Insul
Main
4.1 48
6
8 0
388.0 ft2
0
0' 0.6
0
2 E
Exterior
Concrete Block - Int Insul
Main
4.1 37
2
8 0
297.3 ft2
0
0 0.6
0
3 S
Exterior
Concrete Block - Int Insul
Main
4.1 51
3
8 0
410.0 ft2
0
0 0.6
0
4 SW
Exterior
Concrete Block - Int Insul
Main
4.1 6
2
8 0
49.3 ft2
0
0 0.6
0
5 W
Exterior
Concrete Block - Int Insul
Main
4.1 37
6
8 0
300.0 ft2
0
0 0.6
0
6 -
Garage
Frame - Wood
Main
13 34
0
8 0
272.0 ft2
0
0.23 0.01
0
7 W
Exterior
Concrete Block - Int Insul
Main
4.1 23
6
8 0
188.0 ft2
0
0 0.6
0
8 N
Exterior
Concrete Block - Int Insul
Main
4.1 8
6
8 0
68.0 ft2
0
0 0.6
0
9 S
Exterior
Concrete Block - Int Insul
Main
4.1 6
0
8 0
48.0 ft2
0
0 0.6
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
SW
Insulated Main
None
.25
3
6 8
20 ft2
2
-
Wood Main
None
.25
2
8
6 8
17.8 ft2
3
S
Insulated Main
None
.25
2
4
6 8
15.6 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
# Ornt ID
Frame Panes NFRC
U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1 N
1
Vinyl Low-E Double
Yes
0.55 0.7
N
17.8 ft2
25 ft 0 in
0 ft 10 in
Drapes/blinds
None
2 N
1
Vinyl Low-E Double
Yes
0.33 0.23
N
32.4 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
Exterior 5
3 E
2
Vinyl Low-E Double
Yes
0.33 0.31
N
7.5 ft2
13 ft 0 in
0 ft 6 in
None
None
4 E
2
Vinyl Low-E Double
Yes
0.33 0.31
N
13.3 ft2
13 ft 0 in
2 ft 10 in
None
None
5 E
2
Vinyl Low-E Double
Yes
0.33 0.21
N
32.4 ft2
7 ft 4 in
1 ft 4 in
Drapes/blinds
Exterior 5
6 E
2
Vinyl Low-E Double
Yes
0.33 0.21
N
38.5 ft2
1 ft 4 in
2 ft 0 in
Drapes/blinds
Exterior 5
7 S
3
Vinyl Low-E Double
Yes
0.33 0.23
N
9.8 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
Exterior 5
8 S
3
Vinyl Low-E Double
Yes
0.33 0.23
N
16.2 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
Exterior 5
9 SW
4
Vinyl Low-E Double
Yes
0.33 0.23
N
12.5 ft2
7 ft 2 in
0 ft 4 in
Drapes/blinds
Exterior 5
10 W
5
Vinyl Low-E Double
Yes
0.55 0.7
N
17.8 ft2
9 ft 10 in
0 ft 10 in
Drapes/blinds
None
11 W
5
Vinyl Low-E Double
Yes
0.33 0.23
N
16.7 ft2
7 ft 2 in
0 ft 4 in
Drapes/blinds
Exterior 5
12 W
7
Vinyl Low-E Double
Yes
0.33 0.23
N
30.0 ft2
9 ft 10 in
0 ft 4 in
Drapes/blinds
Exterior 5
13 W
5
Vinyl Low-E Double
Yes
0.33 0.23
N
48.6 ft2
1 ft 4 in
1 ft 2 in
Drapes/blinds
Exterior 5
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
620 ft2 620 ft2
64 ft
8 ft
1
7/20/2021 10:44 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 5
`FORM R405-2020 INP11T Sl1MMARY r14I=CKI IST RFPnPT
INFILTRATION
# Scope Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.000391
2590.3 142.11 266.8 .1312
7
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency Capacity
Block
Ducts
1 Electric Heat Pump/
Split
Singl HSPF:8.5 42 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency Capacity Air Flow
SHR Block
Ducts
1 Central Unit/
Split
Sing[ SEER: 15 42 kBtu/hr cfm
0.75 1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap Use SetPnt
Conservation
1 Electric None
Garage
0.94 40 gal 62.3 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
ftz
DUCTS
---- Supply ----
V # Location R-Value Area
---- Return ---- Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT
QN RLF
HVAC #
Heat Cool
1 Attic 6 503.2 ft
Main
125.8 ft Proposed Qn Main --- cfm 151.4 cfm 0.06 0.60
1 1
TEMPERATURES
Programable Thermostat: Y
Cooling[ Jan Feb Mar
Heatin[X} Jan f X� Feb Mar
Ventin [ ]Jan [ Feb X Mar
Ceiling Fans:
Jul X Aug Se
f APr f May f Jun Julf Au4 SeP
Apr Ma X Jun ri
[X] A r [ Ma [ Jun Jul [ Aug [ Se [X]
Oct Nov
Oct Nov
Oct X Nov
Dec
Dec
Dec
7/20/2021 10:44 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 5
"FORM R405-2020 INPUT SUMMARY rl-IFrKi i-CZT 92FOnOT
Thermostat Schedule:
HERS 2006
Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
PM
66
66
66
66
66
68
68
68
68
68
68
68
68
68
68
68
68
68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture
Fraction
Space
Default 8 lbs/s
.ft.
0 ft2
0 ft
0.3
Main
7/20/2021 10:44 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 5
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the EnergyPerformance Index, the more efficient the home.
8694 Waterstne Boulevard, Fort Pierce, FL, 34951
1. New construction or existing
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
2. Single family or multiple family
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
1748.70 ftZ
b. Frame - Wood, Adjacent
R=13.0
272.00 ftZ
3. Number of units, if multiple family
1
c. N/A
R=
ftZ
4. Number of Bedrooms
4
d. N/A
R=
ftZ
5. Is this a worst case?
No
11. Ceiling Type and insulation level
Insulation
Area
a. Under Attic (Vented)
R=30.0
2523.00 ftZ
6. Conditioned floor area (ftZ)
2523
b. Knee Wall (Vented)
R=19.0
120.00 ftZ
7. Windows" Description
Area
c. N/A
R=
ftZ
a. U-Factor: Dbl, U=0.33
166.06 ftZ
12. Ducts, location & insulation level
R ftZ
a. Sup: Attic, Ret: Main, AH: Main
6 503.2
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33
70.92 ftZ
SHGC: SHGC=0.21
13. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: Dbl, U=0.55
35.56 ftZ
a. Central Unit
42.0 SEER:15.00
SHGC: SHGC=0.70
d. U-Factor: other (see details)
20.83 ftZ
SHGC: other (see details)
14. Heating systems
kBtu/hr
Efficiency
Area Weighted Average Overhang Depth:
6.223 ft.
a. Electric Heat Pump
42.0
HSPF:8.50
Area Weighted Average SHGC:
0.288
8. Skylights Description
Area
15. Hot water systems
a. U-Factor(AVG): N/A
Z
ft
a. Electric
Cap:
40 gallons
SHGC(AVG): N/A
EF:0.94
b. Conservation features
9. Floor Types
Insulation
Area
None
a. Slab -On -Grade Edge Insulation
R=0.0
2523.00 ftZ
Credits (Performance method)
Pstat
b. N/A
R=
ftZ
c. N/A
R=
ftZ
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: Date:
Address of New Home: City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
7/20/2021 10:45 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1