HomeMy WebLinkAboutLetter - Truss Design Packager 258 Southhall Lane, Suite 200 fiF;D Maitland, Florida 32751 P: (321) 972-0491 1 F: (407) 880-2304 1 E: info@fdseng.com 81 Website: www.fdseng.com ENGINEERING ASSOCIATES December 10, 2021 Building Department ram, Ref: Adams Homes Lot: Lot 47 Ph.3 ' Subdivision: Ft. Pierce - Waterstone Address: 8695 Waterstone Blvd. Model: 3000 Mod 2C A LHG KA # 21-10555 Truss Company: Builders First Source. Date of drawings: 8/11/21 Job No.: 2867000 Wind Speed: 160 Exposure: C Truss Engineer: Joaquin Velez To whom it may concern, We have reviewed the truss design package for the project referenced above. This truss package complies with the original design intent and the underlying structure will accommodate all indicated loads. We approve the truss package without comment based upon the truss layout and truss profiles supplied to us by the Truss Company with truss profiles sealed by the Truss Engineer. Please note, this review is only for general conformance with the design concept of the project. Contractor or sub -contractor is responsible for matching all structural components and details shown in the construction documents. Contractor or sub -contractor is also responsible for confirming all quantities and dimensions; selecting appropriate fabrication processes and ,•��� 34&jFa techniques; and coordinating work with all other trades. 1% 0 � k E Note: Truss ID's may vary. If you have any questions, please do not hesitate to call. Sincerely, 12/10/2021 12/10/2021 ,-AGEN' �io 8-' 64 ° <. P TE OF U1 - e � A1-a e���® gdA8�8B® 12/ 0/2021 Carl A. Brown, P.E. Scott Lewkowski, P.E. Luis Pablo Torres, P.E. FL. # 56126 FL. #78750 FL. # 87864 FDS Engineering Associates, A TSG Company "Your Building Code Experts" 4 4 yIN N m E d N N CL W W N 3 Q '47-in-nn I n-t4-tn now I Moo III III ■ C1 C3 C5 C5 C3 C1 15�1 CONNECTORS SCHEDULE ROOF TRUSS QT4 ID MODEL ROOF UPLIFT SYM 0 A. LUS24 / JUS24 895 / 835 490 /510 1LA' 7 A HTU26 / THD26 3600 / 3470 11555 / 2330 11a 0 B HTU28 /THD28 4680 / 5040 2140 / 2330 11.9 1 C HTU26-2 / THD26-2 3600 / 3366 2175 / 2340 1 LC 0 D HTU28-2 / THD28-2 4680 / 5005 3485 / 2595 1 LD 0 E HGUS26-2 / THDH26-2 5320 / 5245 2155 / 2340 1 1 tE 0 F HGUS28-2 / THDH28-2 7460 / 8025 3235 / 3330 1 1 tF 0 G HGUS26-3 / THDH263 5230 / 5246 2155 / 2340 1 LG 0 H HGUS28-3 / THDH283 7460 / 7835 3235 / 4370 1 w 0 J THASR-L29 / 9100 / 8990 4095 / 4370 1 Li 32 3X8NOP CAUTIONM DO NOT ATTEMPT TO ERECT TRUSSES WITHOUT REFERRING TO THE ENGINEERING DRAWINGS AND BSCI-BI SUMMARY SHEETS. ALL PERMANENT BRACING MUST BE IN PLACE PRIOR TO LOADING TRUSSES. fie. SHEATHING, SHINGLES, ETC.) ALL INTERIOR BEARING WALLS MUST BE IN PLACE PRIOR TO INSTALLING TRUSSES. REFER TO FINAL ENGINEERING SHEETS FOR THE FOLLOWING. 1) NUMBER OF GIRDER PLIES AND NAILING SCHEDULE 2) BEARING BLOCK REQUIREMENTS. 3) SCAB DETAILS (IF REQUIRED) 4) UPLIFT AND GRAVITY REACTIONS. WARNING Backcharges Will Nof: Be Accepted Regardless of Fault Without Priory Notification By Customer Within 48 Hours And Investigation By Builders First Source. NO FJ(ECPTIONS. The General Contractor Is Responsible For All Connections Other Than Truss to Truss, Gable Shear Wall, And Connections. Temporary and Permanent Bracing, And Ceiling And Roof Diaphragm Connections. ROOF PITCH: 6112 CEILING PITCH: 3112 TOP CHORD SIZE: 2 X 4 BOTTOM CHORD SIZE: 2 X 4 OVERHANG LENGTH: 16" END CUT: Plumb CANTILEVER: — TRUSS SPACING: 24' BUILDING CODE: FBC2020 BEARING HEIGHT SCHEDULE BUILDER: Adams Homes PROJECT: Single Family Z Reviewed and Approved ❑ Revise and Resubmit MODEL: 3000 A FULL LANAI ❑ Reviewed with Notations ❑ Not Reviewed (see explanation) ADDRESS: 8695 WATERSTONE BLVD Corrections or comments made on equipment submittals or shop drawings during this review do LOT/BLOCK: 47 PH3 not relieve contractor from compliance with requirements of the drawings and specifications. SUBDIVISION: WATERSTONE This check is only for review of general conformance with the concept of the project and CITY: FT PIERCE general compliance with the information given in the contract documents. The contractor is DRAWN BY: KSANCHFZ responsible for con5mring and correlating all quantities and dimensions; selecting fabrication processes and techniques of construction; coordinating his work with that of all other trades and JOB # : 2867000 performing his work in a safe and satisfactory manner DATE: 2021 SCALE: NTS FDS ENGINEERING ASSOCIATES P DATE 2021 Date: 12/10/2021 By. BH REVISIONS: Submittal No.: Project No.: 21-10555 Project Eng.: Luis Tones 1• ' Project Name: Adams Homes - Ft. Pierce - Lot 47 Ph.3 2 3. VERIFY ALL DIMENSIONS AND CEILING CONDITIONS PRIOR TO MMOVAL 4. SOME CEILING FRAMING REQUIRED IN FIELD BY WILDER ENCLOSNO FORCE RESISTWG SYSIEMICC HYBRRIWWO ASCEr-16 IMPORT T ENCLOSED EXPOSURE CATEGORY C MCUPANCYCATEGORYR This Drawing Must a Approved And WIND LOAD 160 MPH Returned Belo Fabrication WillBuilders TRUS ES HAVE BEFACTORNEID TRUSSES HAYE BEEN DESX;ID� FORA 10.0 PSF BOTTOM CHORD LIVE LOAD Begin. Fot Your rQtect Cheek All NONCONCURRM WITH ANY OTNER LIVE LOADS Dimensions And Conditions Prior To l Of ROOF LOADING FLOOR LOADING APBELOW INDDICIC - - ttler SIGNATURE BELOATES ALL NOTES AND DIMENSIONS HAVE TCLL- 20 PSF TCLL: 40 PSF BEEN ACCEPTED. 4408 Airport Road TCDL: 07 PSF TCDL: 10 PSF Plant City, FL 33563 BCDL: 10 PSF BCDL• 6 PSF By Date Ph. (813) 305.1300 Fax (813) 306-1301 TOTAL, 37 PSF TOTAL: 65 PSF DURATION: 1.25 DURATION: 1.00