HomeMy WebLinkAboutEnergy Efficiency CodeIf
FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name:
Lot 58 Block 1 Waterstone 1820 DGL
Street:
8713 Merano Avenue
City, State, Zip:
Fort Pierce , FL , 34951
Owner:
Design Location:
FL, ST_LUCIE_CO_INTL
Builder Name: ADAMS HOMES
Permit Office:
Permit Number:
Jurisdiction: 661000
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing
New (From Plans)
10. Wall Type�2120.0 sqft.)
Insulation Area
2. Single family or multiple family
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1850.00 ft2
3. Number of units, if multiple family
1
b. Frame - Wood, Adjacent
R=13.0 270.00 ft2
c. N/A
R= ft2
4. Number of Bedrooms
4
d. N/A
R= ft2
5. Is this a worst case?
No
11. Ceiling Types (1900.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1820.00 ft2
6. Conditioned floor area above grade (ft2)
1820
b. Knee Wall (Vented)
R=19.0 80.00 ft2
Conditioned floor area below grade (ft2)
0
c. N/A
R= ft2
7. Windows(239.3 sqft.) Description
Area
12. Ducts
R ft2
a. U-Factor: Dbl, U=0.33
168.74 ft2
a. Sup: Attic, Ret: Main, AH: Main
6 364
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33
32.38 ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
35.0 SEER:16.00
c. U-Factor: Dbl, U=0.33
20.42 ft2
SHGC: SHGC=0.31
Area Weighted Average Overhang Depth: 4.067 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC:
0.269
a. Electric Heat Pump
34.6 HSPF:8.50
8. Skylights
Area
c. U-Factor:(AVG) N/A
ft2
15. Hot water systems
SHGC(AVG): N/A
9. Floor Types (1820.0 sqft.)
Insulation Area
a. Electric
Cap: 40 gallons
a. Slab -On -Grade Edge Insulation
R=0.0 1820.00 ft2
b. Conservation features
EF: 0.940
b. N/A
R= ft2
None
c. N/A
R= ft2
16. Credits
Pstat
Glass/Floor Area: 0.131
Total Proposed Modified
Loads: 61.10
PASS
Total Baseline Loads: 64.83
I hereby certify that the plans
this calculation are in compliy
Code.
PREPARED BY: �..•��''
DATE: _ 1717-18-2091 Minn Kpnm;;ny
I hereby certify that this building, as designed, is in compliance
with the Florida Energy Code.
OWNER/AGEN T . r -
DATE:
RevieAof the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
BUILDING OFFICIAL:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). �
7/16/2021 10:34 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 4
FORM R405-2020 INPUT -RUMMARY r141=r1<1 ICT RFPnPT
PROJECT
Title:
Lot 58 Block 1 Waterstone 18 Bedrooms: 4
Address Type:
Lot Information
Building Type:
User
Conditioned Area: 1820
Lot #
58-1
Owner Name:
Total Stories: 1
Block/Subdivision:
Waterstone
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
ADAMS HOMES
Rotate Angle: 0
Street:
8713 Merano Avenue
Permit Office:
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
661000
Whole House Fan: No
City, State, Zip:
Fort Pierce ,
Family Type:
Detached
FL , 34951
New/Existing:
New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp Heating
Design Daily Temp
V/ Design Location
TMY Site 97.5 % 2.5 %
Winter Summer Degree Days Moisture Range
FL, ST LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70 75 299
58 Medium
BLOCKS
Number
Name
Area Volume
1
Block1
1820 18200
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
1820 18200 Yes 5
4 1 Yes
Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 33 ft 0
1820 ft' ___-
0.42 0 0.58
ROOF
/
Roof Gable Roof
Rad Solar SA Emitt
Emitt Deck Pitch
V #
Type
Materials Area Area Color
Barr Absor. Tested
Tested Insul. (deg)
1
Gable or Shed Composition shingles 2035 ftz 456 ftz Medium
N 0.85 N 0.85 No 0 26.57
ATTIC
/
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 1820 ftZ N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 30 Blown
1820 ft' 0.11
Wood
2
Knee Wall (Vented)
Main 19 Batt
80 ftz 0.11
Wood
7/16/2021 10:34 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 4
FORM R405-21121) IIUDI IT CI IRAIIAAIw r•uct-vi ICT ocnnor
WALLS
Adjacent
Space
Cavity Width
Height
Sheathing Framing Solar Below
0
1 E
Exterior Concrete Block - Int Insul
Main
4.1 59 0
10 0
590.0 ft2
0
0 0.6
0
2 N
Exterior Concrete Block - Int Insul
Main
4.1 20 0
10 0
200.0 ft2
0
0 0.6
0
3 W
Exterior Concrete Block - Int Insul
Main
4.1 66 0
10 0
660.0 ft2
0
0 0.6
0
4 S
Exterior Concrete Block - Int Insul
Main
4.1 40 0
10 0
400.0 ft2
0 0.6
0
5 -
Garage Frame - Wood
Main
13 27 0
10 0
270.0 ft2
0
0.23 0.01
0
DOORS
#
Ornt Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
N Insulated
Main
None
.25
3
6 8
20 ft2
2
- Insulated
Main
None
.25
2
8
6 8
17.8 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
V
Wall
Overhang
#
Ornt
ID Frame Panes
NFRC
U-Factor SHGC Imp
Area
Depth
Separation
Int Shade
Screening
1
E
1 Vinyl Low-E Double
Yes
0.33 0.23 N
6.9 ft2
1 ft 4 in
0 ft 10 in
None
Exterior 5
2
E
1 Vinyl Low-E Double
Yes
0.33 0.23 N
48.6 ft2
1 ft 4 in
0 ft 10 in
None
Exterior 5
3
N
2 Vinyl Low-E Double
Yes
0.33 0.31 N
7.1 ft2
9 ft 0 in
0 ft 6 in
None
None
4
N
2 Vinyl Low-E Double
Yes
0.33 0.21 N
16.2 ft2
1 ft 0 in
3 ft 11 in
None
Exterior 5
5
N
2 Vinyl Low-E Double
Yes
0.33 0.21 N
16.2 ft2
1 ft 0 in
5 ft 4 in
None
Exterior 5
6
N
2 Vinyl Low-E Double
Yes
0.33 0.31 N
13.3 ft2
9 ft 0 in
2 ft 0 in
None
None
7
W
3 Vinyl Low-E Double
Yes
0.33 0.23 N
48.6 ft2
1 ft 4 in
0 ft 10 in
None
Exterior 5
8
S
4 Vinyl Low-E Double
Yes
0.55 0.7 N
17.8 ft2
11 ft 5 in
0 ft 6 in
None
Exterior 5
9
S
4 Vinyl Low-E Double
Yes
0.33 0.23 N
32.4 ft2
1 ft 4 in
0 ft 10 in
None
Exterior 5
10
S
4 Vinyl Low-E Double
Yes
0.33 0.23 N
32.4 ft2
11 ft 6 in
0 ft 6 in
None
Exterior 5
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
596 ft2 596 ft2
64 ft
8 ft
1
INFILTRATION
# Scope
Method SLA
CFM 50 ELA EgLA
ACH
ACH 50
1 Wholehouse
Proposed ACH(50) .000444
2123.3 116.49 218.7
.1381
7
HEATING SYSTEM
#
System Type Subtype
Speed Efficiency Capacity
Block
Ducts
1
Electric Heat Pump/ Split
Singl HSPF:8.5 34.6 kBtu/hr
1
sys#1
7/16/2021 10:34 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4
FORM R405-2ngn IAIDI IT CI IIIA11AAoV /+LIC/+IlI is v- mr-
- ■ v. a I IAGr VR 1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit/
Split
Singl SEER: 16 35 kBtu/hr
cfm
0.75
1
sys#1
HOT WATER SYSTEM
#
System Type
SubType
Location
EF Cap Use
SetPnt
Conservation
1
Electric
None
Garage
0.94 40 gal 62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert #
Company Name
System Model # Collector Model
# Area
Volume
FEF
None
None
ftZ
DUCTS
/
---- Supply ----
---- Return --- Air
CFM 25 CFM25
HVAC #
#
Location R-Value
Area
Location
Area Leakage Type Handler
TOT OUT
QN
RLF
Heat Cool
1
Attic
6 364 ftZ
Main
91 ft2 Default Leakage Main
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling Jan
Heating HJan
Venting Jan
Feb
Feb
Mar
Mar
HX
Apr
A r
May X Jun X Jul ri Aug
Ma Jun f Jul Au
]
Se
Se
ri
Oct
Oct
Nov
�Nov
HX
Dec
Dec
Feb
Mar
Apr
May Jun t Jul Aug
Sep
Oct
Nov
H Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6 7
8 9
10
11
12
Cooling (WD)
AM
PM
78
80
78 78
78 78 78 78
78 80
80
80
80
80 78
78 78 78 78
78 78
78
78
78
Cooling (WEH)
AM
PM
78
78
78 78
78 78 78 78
78 78
78
78
78
78 78
78 78 78 78
78 78
78
78
78
Heating (WD)
AM
PM
66
68
66 66
66 66 68 68
68 68
68
68
68
68 68
68 68 68 68
68 68
68
66
66
Heating (WEH)
AM
PM
66
68
66 66
68
66 66 68 68
68 68
68
68
68
68
68 68 68 68
68 68
68
66
66
MASS
Mass Type
Area
Thickness Furniture Fraction Space
L. Default 8 Ibs/s .ft.
0 ft'
0 ft 0.3
Main
7/16/2021 10:34 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 94
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ftz)
7. Windows- Description
a. U-Factor: Dbl, U=0.33
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33
SHGC: SHGC=0.21
c. U-Factor: Dbl, U=0.33
SHGC: SHGC=0.31
d. U-Factor: other (see details)
SHGC: other (see details)
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Skylights Description
a. U-Factor(AVG): N/A
SHGC(AVG): N/A
9. Floor Types
a. Slab -On -Grade Edge Insulation
b. N/A
c. N/A
8713 Merano Avenue, Fort Pierce, FL, 34951
New (From Plans)
10. Wall Type and Insulation
Detached
a. Concrete Block - Int Insul, Exterior
b. Frame - Wood, Adjacent
1
c. N/A
4
d. N/A
No
11. Ceiling Type and insulation level
a. Under Attic (Vented)
1820
b. Knee Wall (Vented)
Area
c. N/A
168.74 ftz
12. Ducts, location & insulation level
a. Sup: Attic, Ret: Main, AH: Main
32.38 ftz
13. Cooling systems
20.42 ftZ
a. Central Unit
17.78 ftz
4.067 ft.
0.269
Area
ftz
Insulation Area
R=0.0 1820.00 ftz
R= ftz
R= ftz
14. Heating systems
a. Electric Heat Pump
15. Hot water systems
a. Electric
b. Conservation features
None
Credits (Performance method)
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: l Date:
Address of New Home: ...... City/FL Zip:
Insulation Area
R=4.1 1850.00 ftz
R=13.0 270.00 ftz
R=
ftz
R=
ftz
Insulation
Area
R=30.0
1820.00 ft2
R=19.0
80.00 ftz
R=
ftz
R ftz
6 364
kBtu/hr
Efficiency
35.0 SEER:16.00
kBtu/hr Efficiency
34.6 HSPF:8.50
Cap: 40 gallons
EF: 0.94
Pstat
`Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
7/16/2021 10:34 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1