Loading...
HomeMy WebLinkAboutLetter Truss Design Package258 Southhall Lane, Suite 200 F D S Maitland, Florida 32751 P: (321) 972-0491 1 F: (407) 880-2304 1 E: info@fdseng.com Website: www.fdseng.com ENGINEERING ASSOCIATES November 17, 2021 Building Department Ref: Adams Homes Lot: Lot 58 Blk.1 Subdivision: Fort Pierce - Waterstone Address: 8713 Merano Ave. Model: 1820 D LHG KA # 21-10143 Truss Company: Date of drawings: Job No.: Wind Speed: Exposure: Truss Engineer: Builders First Source 8/12/2021 2866225 160 C Joaquin Velez To whom it may concern, r !'^ .' dry-, p �• •�. .., ] BOCC We have reviewed the truss design package for the project referenced above. This truss package complies with the original design intent and the underlying structure will accommodate all indicated loads. We approve the truss package without comment based upon the truss layout and truss profiles supplied to us by the Truss Company with truss profiles sealed by the Truss Engineer. Please note, this review is only for general conformance with the design concept of the project. Contractor or sub -contractor is responsible for matching all structural components and details shown in the construction documents. Contractor or sub -contractor is also responsible for confirming all quantities and dimensions; selecting appropriate fabrication processes and techniques; and coordinating work with all other trades. Note: Truss ID's may vary. If you have any questions, please do not hesitate to call. Sincerely, 11/17/2021 11/17/2021 Carl A. Brown, P.E. Scott Lewkowski, P.E. FL. # 56126 FL. #78750 FDS Engineering Associates, A TSG Company "Your Building Code Experts" Luis Pablo T es, P.E. FL. # 87864 .4 J r 10-00-00 N 1'-. NEWS Psi - - - glow ��Illllllll,IIIIIIIII,IIIIIIII,IIIIi- Y -)/12 VLT 2-0 -00 2-00-00 2-0 -00 2-00-00 2- -00 2-00-00 I"PACE 1- -00 2-0 -00 2- -00 ano�nn-n -nn F RG AL 010"- 1/ \1/ L/S 11A Z � o o 3V o EXPOE D TO MND 10'-0"CLG �3/12 VLT A01 CLG 10'-0" LG 3112 VLT CONNECTORS SCHEDULE ROOF TRUSS Q ID MODEL ROOF UPLIFT SYM 0 A-11 LUS24 / JUS24 895 / 835 490 /510 ILA' 9 A HTU26/ THD26 3600 / 3470 1555 / 2330 ILA 0 B HTU28 /THD28 4680 / 5040 2140 / 2330 1LB 0 C HTU26-2 / THD26-2 3600 / 3355 2175 / 2340 1 Lc 0 1 D HTU28-2 / THD28-2 14680 / 5005 3485 / 2595 1 1Io E HGUS26-2 / THDH26-2 5320 / 6245 2155 / 2340 i IE 0 F HGUS28-2 / THDH28-2 7460 / 8026 3235 / 3330 1IF 0 100 G HGUS26-3 /THDH26-3 5230 / 5245 2155 / 2340 1 LG 0 H HGUS28-3 / THDH28-3 7460 / 7835 3235 / 4370 1 w J THJA26 / HJC26 9100 / 8990 4095 / 4370 1 W 3X8NOP El Reviewed and Approved ❑ Revise and Resubmit ❑ Reviewed with Notations ❑ Not Reviewed (see explanation) 17 Corrections or comments made on equipment submittals or shop drawings during this review do 1 -0" C not relieve contractor from compliance with requirements of the drawings and specifications. This check is only for review of general conformance with the concept of the project and z3- o-oo general compliance with the information given in the contract documents. The contractor is responsible for confirming and correlating all quantities and dimensions; selecting fabrication processes and techniques of construction; coordinating his work with that of all other trades and Ails performing his work in a safe and satisfactory manner 10'-0 CLG e'-o' CLG 3/12*VLT < FDS ENGINEERING ASSOCIATES ODD SPACE < Date: 11/17/2021 By: ES Submittal No.: Project No.: 21-10143 Project Eng.: Luis To� o s Project Name: Adams Homes - Fort Pierce - Waterston - Lot 58 Blk 1 CLG 7-08-00 VERIFY ALL DIMENSIONS AND MUM CONDNIONS PRIOR TO APPROVAL SOME CEILING FRAMING REQUIRED IN FIELD BY BUILDER NAINYAND FORCE RESISTING SYSTEWCC HYBRID WAND ASCE7.16 IMPORTANT ENCLOSED E14POSURE CATEGORY C OCCUPANCY CATEGORY B This Drawing Must Be Approved And WAND LOAD t60 CE FACTOR W Returned Before Fabrication Will BE ED TRUSSES HAVE BEEN DESIGNED FOR A1GO PSF BOTTOM CHORD LIVE LOAD US ES RAVE Begin. For Your Protection Check All NONCONCURRENT WITH ANY OTHER LIVE LOADS Dimensions And Conditions Prior To APOf Plan. ROOF LOADING FLOOR LOADING BELO SIGNATURE BELOW INDICATES ALL NOTES IMENSIONS HAVE TCLL• 20 PSF TCLL: 40 PSF BEEN ACCEPTED. TCDL• 07 PSF TCDL• 10 PSF By Date BCDL: 10 PSF BCDL: 5 PSF TOTAL, 37 PSF TOTAL: 65 PSF DURATION: 1.25 DURATION: 1.00 CAUTIONM DO NOT ATTEMPT TO ERECT TRUSSES WITHOUT REFERRING TO THE ENGINEERING DRAWINGS AND BSCI-B1 SUMMARY SHEETS. ALL PERMANENT BRACING MUST BE IN PLACE PRIOR TO LOADING TRUSSES. (is. SHEATHING, SHINGLES, ETC.) ALL INTERIOR BEARING WALLS MUST BE IN PLACE PRIOR TO INSTALLING TRUSSES. REFER TO FINAL ENGINEERING SHEETS FOR THE FOLLOWING. 1) NUMBER OF GIRDER PLIES AND NAILING SCHEDULE 2) BEARING BLOCK REQUIREMENTS. 3) SCAB DETAILS (IF REQUIRED) 4) UPLIFT AND GRAVITY REACTIONS. WARNING Backcharges Will Not Be Accepted Regardless of Fault Without Prior Notification By Customer Within 48 Hours And Investigation By Builders First Source. NO EXECPTIONS. The General Contractor Is Responsible For All Connections Other Than Truss to Truss, Gable Shear Wall, And Connections. Temporary and Permanent Bracing, And Ceiling And Roof Diaphragm Connections. ROOF PITCH: 6112 CEILING PITCH: 3112 TOP CHORD SIZE: 2 X 4 BOTTOM CHORD SIZE: 2 X 4 OVERHANG LENGTH: 16" END CUT: Plumb CANTILEVER: — TRUSS SPACING: ZV BUILDING CODE: FBC2020 BEARING HEIGHT SCHEDULE BUILDER Adams Homes PROJECT: Single Family MODEL: 1820 D 3CAR ADDRESS: 1 8713 MERANO AVE LOT/BLOCK: 68N SUBDIVISION: WATERSTONE CITY: FT PIERCE DRAWN BY: KSANCHEZ JOB #: 2866225 DATE: 08110/2021 SCALE: NTS PLAN DATE: 2021 REVISIONS: 1. 2. 3. 4. 4408 Airport Road Plant City, FL 33563 Ph. (813) 305-1300 Fax(813) 306.1301