HomeMy WebLinkAboutEnergy Efficiency Coder
` FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Lot 114 Phase 3 Waterstone 1820 BGR Builder Name: ADAMS HOMES
Street: 5337 Lugo Street Permit Office:
City, State, Zip: Fort Pierce , FL, 34951 Permit Number:
Owner: Jurisdiction: 661000
Design Location: FL, ST_LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Type42120.0 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1850.00 ftZ
3. Number of units, if multiple family 1
b. Frame - Wood, Adjacent
R=13.0 270.00 ftZ
c. N/A
R= ftZ
4. Number of Bedrooms 4
d. N/A
R= ftZ
5. Is this a worst case? No
11. Ceiling Types (1900.0 sgft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1820.00 ftZ
6. Conditioned floor area above grade (ftZ) 1820
b. Knee Wall (Vented)
R=30.0 80.00 ftZ
Conditioned floor area below grade (ftZ) 0
c. N/A
R= ftZ
7. Windows(239.3 sqft.) Description Area
12. Ducts
R ftZ
a. U-Factor: Dbl, U=0.33 136.36 ftZ
a. Sup: Attic, Ret: Main, AH: Main
6 364
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33 32.38 ftZ
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
35.0 SEER:16.00
c. U-Factor: Dbl, U=0.30 32.38 ftZ
SHGC: SHGC=0.23
Area Weighted Average Overhang Depth: 4.251 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.269
a. Electric Heat Pump
34.6 HSPF:8.50
8. Skylights Area
c. U-Factor:(AVG) N/A ftZ
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 40 gallons
9. Floor Types (1820.0 sqft.) Insulation Area
EF:0.940
a. Slab -On -Grade Edge Insulation R=0.0 1820.00 ftZ
b. Conservation features
b. N/A R= ftZ
None
c. N/A R= ftZ
16. Credits
Pstat
Glass/Floor Area: 0.131 Total Proposed Modified Loads: 60.02
PASS
Total Baseline Loads: 64.83
I hereby certify that the plan cifications cover
Re w of the plans and
��TAE Sr91,
this calculation are in co a I nergy
specifications covered by this
_
80A
Code.
calculation indicates compliance
with the Florida Energy Code.
{rh; �r�r;,•;;;,'a ,� p
PREPARED BY:
Before construction is completed'
DATE: 1717-71-2021 N*nn Kenm=ny
this building will be inspected for
'R
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
the Florida
Florida Statutes.
" ;S
with ne de.!G,pDtl`'
OWNER/AGENT. ---.
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2)._�
f I n. pm
:7WS a jbf
7/21/2021 3:52 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Pagel of 4
FORM R405-2020
INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
Lot 114 Phase 3 Waterstone Bedrooms: 4
User Conditioned Area: 1820
Total Stories: 1
1 Worst Case: No
ADAMS HOMES Rotate Angle: 0
Cross Ventilation: No
661000 Whole House Fan: No
Detached
New (From Plans)
Address Type:
Lot #
Block/Subdivision:
PlatBook:
Street:
County:
City, State, Zip:
Lot Information
114 Phase3
Waterstone
5337 Lugo Street
St. Lucie
Fort Pierce ,
FL, 34951
CLIMATE
/
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70 75 299
58 Medium
BLOCKS
Number
Name
Area Volume
1
Block1
1820 18200
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfIIID Finished Cooled Heated
1
Main
1820 18200 Yes 5
4 1 Yes
Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 33 ft 0
1820 ft2 ----
0.42 0 0.58
ROOF
/
V #
Type
Roof Gable Roof
Materials Area Area Color
Rad Solar SA Emitt
Barr Absor. Tested
Emitt Deck Pitch
Tested Insul. (deg)
1
Gable or Shed Composition shingles 2035 ft2 456 ft2 Medium
N 0.85 N 0.85 No 0 26.57
ATTIC
/
�/ #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 1820 ft2 N N
#
Ceiling Type
CEILING
Space R-Value Ins Type Area Framing Frac Truss Type
1
2
Under Attic (Vented)
Knee Wall (Vented)
Main 30 Blown
Main 30 Batt
1820 ft2 0.11
80 ft2 0.11
Wood
Wood
7/21/2021 3:52 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 4
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Space
Cavitylip Width Height
Sheathing Framing Solar Below
0
1 N
Exterior Concrete Block - Int Insul Main
4.1 59 0 10 0 590.0 ft2
0
0 0.6
0
2 E
Exterior Concrete Block - Int Insul Main
4.1 20 0 10 0 200.0 ft2
0
0 0.6
0
3 S
Exterior Concrete Block - Int Insul Main
4.1 66 0 10 0 660.0 ft2
0
0 0.6
0
4 W
Exterior Concrete Block - Int Insul Main
4.1 40 0 10 0 400.0 ft2
0 0.6
0
5 -
Garage Frame - Wood Main
13 27 0 10 0 270.0 ft2
0
0.23 0.01
0
DOORS
#
Ornt Door Type Space
Storms U-Value
Width
Height
Area
Ft
In
Ft In
1
E Insulated Main
None .25 3
6 8
20 ft2
2
- Wood Main
None .25 2
8
6 8
17.8 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
V #
Ornt ID Frame Panes NFRC
U-Factor SHGC Imp Area Depth
Separation
Int Shade
Screening
1
N 1 Vinyl Low-E Double Yes
0.33 0.23 N 6.9 ft2 1 ft 4 in
0 ft 10 in
None
Exterior 5
2
N 1 Vinyl Low-E Double Yes
0.33 0.23 N 48.6 ft' 1 ft 4 in
0 ft 10 in
None
Exterior 5
3
E 2 Vinyl Low-E Double Yes
0.33 0.31 N 7.1 ft2 9 ft 4 in
0 ft 0 in
None
None
4
E 2 Vinyl Low-E Double Yes
0.33 0.21 N 16.2 ft2 1 ft 4 in
1 ft 0 in
None
None
5
E 2 Vinyl Low-E Double Yes
0.33 0.21 N 16.2 ft' 1 ft 4 in
1 ft 0 in
None
Exterior 5
6
E 2 Vinyl Low-E Double Yes
0.33 0.31 N 13.3 ft' 9 ft 4 in
1 ft 6 in
None
None
7
S 3 Vinyl Low-E Double Yes
0.33 0.23 N 48.6 ft' 1 ft 4 in
0 ft 10 in
None
Exterior 5
8
W 4 Vinyl Low-E Double Yes
0.55 0.7 N 17.8 ft' 12 ft 0 in
0 ft 6 in
None
None
9
W 4 Vinyl Low-E Double Yes
0.3 0.23 N 32.4 ft' 1 ft 4 in
0 ft 10 in
None
Exterior 5
10
W 4 Vinyl Low-E Double Yes
0.33 0.23 N 32.4 ft2 12 ft 0 in
0 ft 6 in
None
Exterior 5
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter Avg. Wall Height
Exposed Wall Insulation
1
596 ft2 596 ft2
64 ft 8 ft
1
INFILTRATION
# Scope
Method SLA CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000444 2123.3 116.49 218.7 .1381
7
HEATING SYSTEM
#
System Type Subtype
Speed Efficiency Capacity
Block
Ducts
1
Electric Heat Pump/ Split
Sing] HSPF:8.5 34.6 kBtu/hr
1
sys#1
7/21/2021 3:52 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4
FORM R405-2n20 IAIPI IT CI IRRRAADV ruer+iei ter oCo^or
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit/
Split
Singl SEER: 16 35 kBtu/hr
cfm
0.75
1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap Use
SetPnt
Conservation
1 Electric
None
Garage
0.94 40 gal 62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert # Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ft2
DUCTS
/ ---- Supply ----
--- Return--- Air
CFM 25 CFM25
HVAC #
# Location R-Value
Area
Location
Area Leakage Type Handler
TOT OUT
QN
RLF
Heat Cool
1 Attic
6 364 ft'
Main
91 ftz Default Leakage Main
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling an Feb
Heating f X] Jan Feb
Venting
Mar
Mar
Apr [
APr [
Jul rl Aug
May f Jun JulAuE
Ma X Jun rl
X Se
SeP
Oct
Oct
Nov
Nov
Dec
Dec
H
[ ]Jan Feb
X Mar
A r [[[
Ma [ Jun Jul Aug
Se [X]
Oct
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6 7
8 9
10
11
12
Cooling (WD) AM
PM
78
80
78 78
80
78 78 78 78
78 80
80
80
80
78
78 78 78 78
78 78
78
78
78
Cooling (WEH) AM
PM
78
78
78 78
78
78 78 78 78
78 78
78
78
78
78
78 78 78 78
78 78
78
78
78
Heating (WD) AM
PM
66
68
66 66
68
66 66 68 68
68 68
68
68
68
68
68 68 68 68
68 68
68
66
66
Heating (WEH) AM
PM
66
68
66 66
66 66 68 68
68 68
68
68
68
68 68
68 68 68 68
68 68
68
66
66
MASS
Mass Type
Area
Thickness Furniture Fraction Space
Default 8 Ibs/s .ft.
0 ftz
0 ft 0.3
Main
7/21/2021 3:52 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 4
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 93
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ftz)
7. Windows" Description
a. U-Factor: Dbl, U=0.33
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33
SHGC: SHGC=0.21
c. U-Factor: Dbl, U=0.30
SHGC: SHGC=0.23
d. U-Factor: other (see details)
SHGC: other (see details)
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Skylights Description
a. U-Factor(AVG): N/A
SHGC(AVG): N/A
9. Floor Types
a. Slab -On -Grade Edge Insulation
b. N/A
c. N/A
5337 Lugo Street, Fort Pierce, FL, 34951
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
1850.00 ftz
b. Frame - Wood, Adjacent
R=13.0
270.00 ftz
1
c. N/A
R=
ftz
4
d. N/A
R=
ftz
No
11. Ceiling Type and insulation level
Insulation
Area
a. Under Attic (Vented)
R=30.0
1820.00 ftz
1820
b. Knee Wall (Vented)
R=30.0
80.00 ftz
Area
c. N/A
R=
ftz
136.36 ftz
12. Ducts, location & insulation level
R ftz
a. Sup: Attic, Ret: Main, AH: Main
6 364
32.38 ftz
13. Cooling systems
kBtu/hr
Efficiency
32.38 ftz
a. Central Unit
35.0 SEER:16.00
38.19 ftz
4.251 ft.
0.269
Area
ftz
Insulation Area
R=0.0 1820.00 ftz
R= ftz
R= ftz
14. Heating systems
a. Electric Heat Pump
15. Hot water systems
a. Electric
b. Conservation features
None
Credits (Performance method)
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: ( Date:
Address of New Home:
City/FL Zip:
kBtu/hr Efficiency
34.6 HSPF:8.50
Cap: 40 gallons
EF: 0.94
Pstat
`Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
7/21/2021 3:52 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1