Truss
Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others. MiTek RE: 2866952 - 1820 B 3CAR BLK NO HS MiTek USA, Inc. Site Information: 16023 Swingley Ridge Rd Customer Info: Adams Homes Port St Lucie Project Name: 1820 B 3CAR Model31 e,Cf41�, Lot/Block: 114PH3 Subdivision: WATERSTON& 5337 LugoSt�I122��0� Address: 5337 Lugo St, . City: Fort Pierce State: FL Name Address and License # of Structural Engineer of Record, If there is one, for the building. Name: License #: Address: City: State: General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC2020/TP12014 Design Program: MiTek 20/20 8.4 Wind Code: ASCE 7-16 Wind Speed: 160 mph Roof Load: 37.0 psf Floor Load: N/A psf This package includes 37 individual, Truss Design Drawings and 0 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61 G15-31.003, section 5 of the Florida Board of Professional Engineers Rules. No. Seal# Truss Name Date 1 147880225 A01 9/14/21 2 147880226 A02 9/14/21 3 147880227 A03 9/14/21 4 147880228 A04 9/14/21 5 147880229 A05 9/14/21 6 147880230 A06 9/14/21 7 147880231 A07 9/14/21 8 147880232 A08 9/14/21 9 147880233 A09 9/14/21 10 147880234 A10 9/14/21 11 147880235 A11 B 9/14/21 12 147880236 Al2B 9/14/21 13 147880237 B02B 9/14/21 14 147880238 B03B 9/14/21 15 147880239 B04B 9/14/21 16. 147880240 B05B 9/14/21 17 147880241 C 1 9/14/21 18 147880242 C 1 B 9/14/21 19 147880243 C1 P 9/14/21 20 147880244 C 1 V 9/14/21 21 147880245 C3 9/14/21 22 147880246 C3B 9/14/21 No. Seal# Truss Name Date 23 147880247 C3V 9/14/21 24 147880248 C5 9/14/21 25 147880249 C5B 9/14/21 26 147880250 C5V 9/14/21 27 147880251 D02B 9/14/21 28 147880252 E3 9/14/21 29 147880253 E7 9/14/21 30 147880254 E7V 9/14/21 31 147880255 E7VP 9/14/21 32 147880256 H3 9/14/21 33 147880257 H7 9/14/21 34 147880258 H7V 9/14/21 35 147880259 K20 9/14/21 36 147880260 K21 9/14/21 37 147880261 K23 9/14/21 The truss drawing(s) referenced above have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by Builders FirstSource (Plant City, FL). Truss Design Engineer's Name: Johnson, Andrew My license renewal date for the state of Florida is February 28, 2023. IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek or TRENCO. Any project specific information included is for MiTek's or TRENCO's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek or TRENCO has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSl/TPI 1, Chapter 2. REWEWED �-Uh CODE COLIVIIPUANCE ST. LUC UE coUN Ty SO= ���Ill a ul/000 EW JOyti G•E N SO,L No 4 3 : cc 10 S TAT OF Andrew Johnson PE No.84943 MiTek USA, Inc. FL Cert 6634 16023 Ungley Ridge Road, Chesterfield, MO 63017 Date: September 14,2021 Johnson, Andrew 1 of 1 Job Truss Truss Type Qty Ply 1820 B 3CAR BLK NO HS 147880225 2866952 - A01 SPECIAL - - 8 -11 - Job Reference (optional) Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Sep 13 15:10:49 2021 Page 1 I D:193QG W BBpX3j Rl87zeOm7kz5?ad-G RgN2zG72xjaZKtLN?nOdoc4QgYsDkb9AVCW Baye?sq �•4-0, 6-3-0 11.11-12 19-10-0 27-8-4 33-5-0 39.8-0 At-0 q 1-4-0 6.3.0 5-8-12 7-10-4 7-10-4 5.8-12 6.3-0 5x6 = 6.00 12 Scale = 1:72.2 ST1.5x8 STP= ST1.5x8 STP= 5x12 3.00 12 5x12 17-6-8 22-1.8 31-0-0 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TIC 0.96 Vert(LL) 0.49 10-11 >960 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.75 Vert(CT) -0.83 10-11 >561 180 BCLL 0.0 Rep Stress Incr YES WB 0.71 Horz(CT) 0.48 8 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix-SH Weight: 230lb FT=20% LUMBER- BRACING - TOP CHORD 2x4 SP M 31 *Except* TOP CHORD Structural wood sheathing directly applied. 1-4,6-9: 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 6-1-9 oc bracing. BOT CHORD 2x6 SP M 26 *Except* WEBS 1 Row at midpt 6-11, 4-12 13-14,10-13: 2x6 SP No.2 WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 8=0-8-0 Max Horz 2=433(LC 9) Max Uplift 2= 810(LC 10), 8=-810(LC 10) Max Grav 2=1782(LC 15), 8=1782(LC 16) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-5794/2627, 3-4=-5560/2469, 4-5=-2715/1481, 5-6=-2676/1481, 6-7=-5238/2469, 7-8=-5483/2628 BOT CHORD 2-14=-2202/5538, 12-14=-1441/3786, 11-12=-649/2204, 10-11=-1441/3291, 8-10=-2202/4922 WEBS- - 5-11= 425/1139, 6-1 1=-1436/820,6-10=-682/2000; 7-10=-188/281, 5-12=-425/1190, 4-12=-1522/820, 4-14=-682/2184, 3-14=-173/281 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-4-0 to 2-7-10, Interior(1) 2-7-10 to 15-10-6, Exterior(2R) 15-10-6 to 23-9-10, Interior(1) 23-9-10 to 37-0-6, Exterior(2E) 37-0-6 to 41-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has-been designed for a live load of-20.0psf on the bottom chord in -all areas where a rectangle 3-6-0 tall by 2-0-1) wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 6) Bearing at joint(s) 2, 8 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 810 lb uplift at joint 2 and 810 lb uplift at joint 8. i.- Andrew Johnson PENo: 84943 JiTek USA, Inc PL Cert 6634 16023 Ssringley IUdge Road, Chesterfield, NO 63017 Date: September 14,2021 0 0 141 N 6 ®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. —D'esign valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not• a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the - fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTP11 Quality Criteria, DSB-89 and BCSI Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type Qty Ply 1820 B 3CAR BLK NO HS 147880226 2866952- A02 SPECIAL 2 -1- Job Reference (optional) �uuucw n,atouw �e Ir,ant uuy, rt_), r,aia linty, FL - 00001, a.431J s Mug 10 ZUZ I Ivm l eK Inausines, Inc. ivion oep id i o:l u:o I ZUZ7 rage 1 ID:193QGW BBpX3j RI87zeOm7kz5?ad=Cpy7TfHNZZzloel jVQgsi DhRveBehe8SephdDSye?so r1-4 q 6-3-0 11-11-12 19-0-0 20-8-0 27-B-4 33-5-0 39.8-0 41-0-Q 1-4-0 6-3-0 5-B•12 7-0-4 1-8-0 7-0-4 5.8-12 6-3-0 1-4-0 M 0 6.00 rl2 5x6 = 5x6 = 5 6 0 ST1.5x8 STP = 3x4 = ST1.5x8 STP — 6x8 3.00 12 6x8 8-8.0 4-2-9 4-2-9 Scale=1:75.1 LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC2020/TP12014 CSI. TIC 0.90 BC 0.86 WB 0.70 Matrix-SH DEFL. in (loc) I/deft Ud Vert(LL) 0.53 12 >890 240 Vert(CT) -0.80 11-12 >584 180 Horz(CT) 0.54 9 n/a n/a PLATES GRIP MT20 244/190 Weight: 218lb FT=20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 *Except* TOP CHORD Structural wood sheathing directly applied. 1-4,7-10: 2x4 SP No.1 BOT CHORD Rigid ceiling directly applied or 4-2-2 oc bracing. BOT CHORD 2x4 SP No.2 *Except* 2-16,9-11: 2x4 SP No.1 WEBS 2x4 SP No.3 WEDGE Left: 2x4 SP No.3 , Right: 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 9=0-8-0 Max Horz 2=-417(LC 8) Max Uplift 2= 81 O(LC 10), 9=-81 O(LC 10) Max Grav 2=1533(LC 1), 9=1533(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-4678/2623, 3-4=-4460/2503, 4-5=-2621/1685, 5-6=-1866/1397, 6-7=-2621/1685, 7-8=-4460/2503, 8-9=-4678/2623 BOT CHORD 2=16=-2192/4471, 15-16— 1473/3093, 13-15=-740/1864, 12-13=-740/1862, 11-12=-1473/2962, 9-11= 2192/4181 WEBS 4-16=-695/1675, 4-15=-1162/756, 5-15= 535/1071, 5-13=-261/320, 6-13=-261/320, 6-12=-535/1010, 7-12=-1086/756, 7-11= 695/1545 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASIDE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft B=45ft; L=40ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-4-0 to 2-7-10, Interior(1) 2-7-10 to 15-0-6, Exterior(2R) 15-0-6 to 24-7-10, Interior(1) 24-7-10 to 37-0-6, Exterior(2E) 37-0-6 to 41-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific' to the use of this truss component. - 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord jive load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 2, 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 810 lb uplift at joint 2 and 810 lb uplift at joint 9. Audrew Johnson PENo. 84943 MiTek USA, lac. FL Ced 6634 16023 Sslingley Ridge Road, Chesterfield,110 63017 Date: -September 14,2021 - A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. - -Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not• a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the - fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTP11 Quality Criteria, DSB-89 and SCSI Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type Qty Ply 1820 B 3CAR BLK NO HS 147880227 2866952 A03 SPECIAL 2 1 - - - Job Reference (optional) Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Sep 13 15:10:53 2021 Page 1 ID:193QGW BBpX3jR187zeOm7kz57ad-BC3uuLJe5AD01 xB6crsKnempvRtn9Vvk57AjHLye7sm r1-4-q 6-3-0 11-11-12 , 17.0-0 22-8-0 27-8-5 33-5-0 39-8-0 ¢1-0-Q 1-4-0 6-3.0 5-8-12 5-0-5 5-8-0 5-0-4 5-8-12 6-3-0 1-4.0 Scale=1:75.1 6.00 12 5x6 = 5xB = 0 0 Iv- 0 ST1.5x8 STP= ST1.5x8 STP= 5x8 3.00 12 5x8 ZZ 8-8-0 17.0-0 22-8-0 31-0-0 39-6-0 B-8-0 8-4.0 5.8.0 8-4-0 B--0 Plate Offsets (X,Y)--[2:0-5-3,0-1-6],[4:0-3-0,0-3-0],[5:0-3-0,0-2-0],[6:0-6-0,0-2-81,[7:0-3-0,0-3-0][9:0-5-3,0-1-6],[11:0-4-0,0-4-8],[15:0-3-12,0-4-8] LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.80 Vert(LL) 0.53 11-12 >891 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.88 Vert(CT) -0.79 11-12 >590 180 BCLL 0.0 Rep Stress Incr YES WB 0.94 Horz(CT) 0.49 9 n/a n/a BCDL 10.0 Code FBC2020[TP12014 Matrix-SH Weight: 235lb FT=20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD 2x6 SP No.2 BOT CHORD Rigid ceiling directly applied or 4-8-6 oc bracing. WEBS 2x4 SP No.3 WEBS 1 Row at midpt 6-14 REACTIONS. (size) 2=0-8-0, 9=0-8-0 Max Horz 2=376(LC 9) Max Uplift 2=-810(LC 10), 9=-810(LC 10) Max Grav 2=1533(LC 1). 9=1533(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3= 4846/2901, 3-4=-4578/2723, 4-5=-2453/1692, 5-6=-2150/1604, 6-7=-2451/1691, 7-8=-4578/2723, 8-9=-4846/2901 BOT CHORD 2-15=-2453/4599, 14-15=-1599/3074, 12-14=-998/2148, 11-12=-1599/2984, 9-11=-2453/4352 WEBS 3-15=-261/317, 4-15=-775/1762, 4-14=-1183/761, 5-14=-394/792, 6-12= 394/816, 7-12=-1111[761, 7-11=-775/1647, 8-11=-275/317 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASIDE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-4-0 to 2-7-10, Interior(1) 2-7-10 to 13-0-6, Exterjor(2R) 13-0-6 to 26-7-10, Interior(1) 26-7-10 to 37-0-6, Exterior(2E) 37-0-6 to 41-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 2, 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 810 lb uplift at joint 2 and 810 lb uplift at joint 9. Andrew Johnson PE No. 94943 JDiek USA, Inc. FL Ced 6634 16023 Srvmgley Ridge Read, Chesterfield, h10 63017 Dale: September 14,2021 0 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. -Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not• a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing Indicated into prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek Is always -required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTPI1 Quality Criteria, DSB-89 and SCSI Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type Qty Ply 1820 B 3CAR BLK NO HS 147880228 2866952 A04 SPECIAL - 2-- 1 - - - - - Job Reference (optional) Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Sep 13 15:10:55 2021 Page 1 ID:193QG W BBpX3j R187zeOm7kz5?ad-5bBel1 KudnTj H FL-VkGuos3s91 FaOdVwl ZRfgMDye?sk r1-4-q 5-11-1 9-6-9 15-0-0 19-10-0 2±13-0 30-1-7 33-8-15 39-6.0 11-0-q 1-4.0 5-11-1 3-7-9 5-5-7 4-10-0 4-10-0 5-5-7 3-7-9 5-11-1 1-4-0 Scale = 1:75.1 dI 0 6.00 12 5x6 = 3x4 = 5x6 = 19 6 20 7 ST1.5x8 STP = ST1.5x8 STP = 5x12 % 3.00 rl2 Sx12 8-8-0 15-0.0 24-8-0 31-0-0 39.No 8-8.02 i 6-4-0 9-8-0 6.4-0 8.8-0 Plate Offsets (X,Y)-- [2:0-0-3,1-11-7], [2:0-3-7,Edge], [4:0-3-0,0-3-0], 15:0-3-0,0-2-0], [7:0-3-0,0-2-0], [8:0-3-0,0-3-0], [10:0-0-3,1-11-7], [10:0-3-7,Edge], [12:0-3-8,0-5-0], [16:0-3-8,0-5-01 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/dell Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.83 Vert(LL) 0.48 13-15 >975 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.81 Vert(CT) -0.84 13-15 >560 180 BCLL 0.0 Rep Stress Incr YES WB 0.53 Horz(CT) 0.48 10 n/a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix-SH Weight: 237lb FT=20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD 2x6 SP M 26 *Except* BOT CHORD Rigid ceiling directly applied or 5-0-14 oc bracing. 14-16,12-14: 2x6 SP No.2 WEBS 1 Row at midpt 4-15, 8-13 WEBS 2x4 SP No.3 WEDGE Left: 2x4 SP No.3, Right: 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 10=0-8-0 Max Horz 2=335(LC 9) Max Uplift 2=-81 O(LC 10), 10=-81 O(LC 10) Max Grav 2=1791(LC 15), 10=1791(LC 16) FORCES. (lb) -Max, Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-5703/2964, 3-4=-5526/2858, 4-5=-3211/1882, 5-6=-2872/1788, 6-7=-2776/1788, 7-8=-3105/1882, 8-9=-5278/2858, 9-10=-5465/2964 BOT CHORD - 2=1 6=-2507/5375, 15-16=-2095/4637, 13-15=-1368/2990, 12-13= 2095/4197, - 10-12=-2507/4901 WEBS 4-16=-587/1599, 4-15=-1857/965, 5-15=-495/1140, 7-13=-495/1148, 8-13=-1751/965, 8-12=-587/1485, 6-15=-332/201, 6-13=-332/201 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASIDE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-4-0 to 2-7-10, Interior(1) 2-7-10 to 11-0-6, Exterior(2R) 11-0-6 to 18-11-10, Interior(1) 18-11-10 to 20-8-6, Exterior(2R) 20-8-6 to 28-7-10, Interior(1) 28-7-10 to 37-0-6, Exterior(2E) 37-0-6 to 41-0-0 zone;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying _ap_ plied roof live load shown covers_ rain loading requirements specific to the use of this truss component. - 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = I O.Opsf. 7) Bearing at joint(s) 2, 10 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 810 lb uplift at joint 2 and 810 lb uplift at AndrewJohnsonPENo.84943 joint 10. \LTekUSA,Inc. FLCed6634 16013 Swiaoey Ridge Road, Chesterfield, lt0 63017 Date: - -September 14,2021 WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. - Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and propedy incorporate this design into the overall building design. Bracing indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek" is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTP11 Quality Criteria, DSB-89 and BCSI Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type Oily Ply 1820 B 3CAR BLK NO HS 147880229 2866952 A05 SPECIAL 1 1 Job Reference (optional) Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Sep 13 15:10:57 2021 Page 1 ID:193QG W BBpX3j RI87zeOm7kz57ad-1 zJ PjjM89PkR W ZUtrhwGxUxUX2DF5MkKO18xQ6ye7si 1-4-q 6.8.0 13.0.0 19-10-0 26-B-0 33-0.0 39-8-0 41-0-q 1-4.0 6-8-0 6-10-0 6-10-0 6.4-0 6.8-0 1-4-0 m O Sx6 = 6.00 12 _ 3x4 = 5x6 = 4 17 18 5 19 206 ST1.5x8 STP = ST1.5xB STP = 6x8 % 3.00 F12 8-8.0 6x8 Scale=1:75.1 LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 * BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC2020[TP12014 CSI. TC 0.89 BC 0.91 WB 0.76 Matrix-SH DEFL. in (loc) I/deft Ud Vert(LL) 0.55 11-13 >845 240 Vert(CT) -0.89 11-13 >526 180 Horz(CT) 0.57 8 n/a n/a PLATES GRIP MT20 244/190 Weight: 190 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP M 31 *Except* TOP CHORD Structural wood sheathing directly applied. 4-6: 2x4 SP No.2, 1-3,7-9: 2x4 SP No.1 BOT CHORD Rigid ceiling directly applied or 3-10-15 oc bracing. BOT CHORD 2x4 SP No.2 *Except* 2-14,8-10: 2x4 SP No.1 WEBS 2x4 SP No.3 WEDGE Left: 2x4 SP No.3, Right: 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 8=0-8-0 Max Horz 2=-294(LC 8) Max Uplift 2=-81 O(LC 10), 8=-81 O(LC 10) Max Grav 2=1533(LC 1), 8=1533(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-4722/2949, 3-4=-4466/2806, 4-5=-2924/2005, 5-6=-2924/2005, 6-7=-4466/2806, 7-8=-4722/2949 BOT CHORD 2-14=-2492/4340, 13-14=-1444/2714, 11-13=-1702/3110, 10-11= 1444/2714, 8-10=-2492/4222 WEBS 3-14= 282/338, 4-14=-985/1859, 4-13=-142/522, 5-13=-394/275, 5-11=-394/275, 6-11 =-1 42/522, 6-10= 985/1749, 7-10=-292/338 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-4-0 to 2-7-10, Interior(1) 2-7-10 to 9-0-6, Exterior(2R) 9-0-6 to 16-11-10, Interior(1) 16-11-10 to 22-8-6, Exterior(2R) 22-8-6 to 30-7-10, Interior(1) 30-7-10 to 37-0-6, Exterior(2E) 37-0-6 to 41-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. - 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 2, 8 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 810 lb uplift at joint 2 and 810 lb uplift at AndrewJohasoaPENo.84943 joint 8. 1LTekUSA, Inc. FLCent 6634 160I3 Snfal;ley Ridge Road, Chesferfleld,110 63017 Date: September 14,2021 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020BEFORE USE. - Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not, a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MITe'k• is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the _ fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute; 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type Qty Ply 1820 B 3CAR BLK NO HS 147880230 2866952 A06 SPECIAL Job Reference (optional) ouuuers mrsrauuree triarn uny, rL/, riant ldty, rL - JJObf, 6.43U S Aug 1 b 2U'21 MI I eK Industries, Inc. Mon Sep 13 15:11:UU 2U21 rage 1 - ID:193QGWBBpX3jR187ze0m7kz5?ad-RY?XMkO1 SK60NODSXpUzZ6Zz4GGglmzmijMbl Rye?sf r1-4-C] 5-11-1 11-0-0 17.0-0 22-8.0 28-8-0 33-8-15 39-8-0 41-0 q 1-4-0 5-11-1 5-0-15 6-0-0 5-8-0 6-0-0 5-0-15 5-11-1 1-4-0 co O 5x6 = 2x4 II 5x6 = - 5x6 = 18 19 5 6 20 21 7 ST1.5x8 STP = ST1.5x8 STP = 6x8 % 3.00 F12 6x8 ZZ Scale = 1:73.6 8-8-0 16-10-11 22-9-5 31.0-0 39-6.0 8-8-0 8-2-11 5-10-11 8-2-11 8-8-0 Plate Offsets (X,Y)-- [2:0-5-9,Edgel, [4:0-3-8,0-2-4], [6:0-3-0,0-3-01, [7:0-3-8,0-2-41, [9:0-5-9 Edge] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.94 Vert(LL) 0.68 12-14 >689 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.86 Vert(CT) -0.97 12-14 >481 180 BCLL 0.0 Rep Stress Incr YES WB 0.54 Horz(CT) 0.57 9 n/a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix-SH Weight: 209lb FT=20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied. BOT CHORD 2x4 SP No.1 *Except* BOT CHORD Rigid ceiling directly applied or 3-11-8 oc bracing. 13-15,11-13: 2x6 SP No.2 WEBS 2x4 SP No.3 WEDGE Left: 2x4 SP No.3, Right: 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 9=0-8-0 Max Horz 2=-253(LC 8) Max Uplift 2= 81 O(LC 10), 9=-81 O(LC 10) Max Grav 2=1533(LC 1), 9=1533(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3= 4676/2926, 3-4=-4455/2724, 4-5=-3991/2570, 5-6=-3991/2571, 6-7=-3994/2572, 7-8=-4455/2724, 8-9=-4675/2926 BOT CHORD 2-15=-2472/4227, 14-15=-1709/3153, 12-14=-2149/4007, 11-12=-1710/3155, 9-11=-2472/4178 WEBS 3-15=-214/309, 4-15=-702/1462, 4-14=-493/1086, 5-14=-319/298, 6-12=-376/300, 7-12=-493/1086, 7-11=-699/1408, 8-11=-227/308 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-4-0 to 2-7-10, Interior(1) 2-7-10 to 7-0-6, Exterior(2R) 7-0-6 to 14-11-10, Interior(1) 14-11-10 to 24-8-6, Exterior(2R) 24-8-6 to 32-7-10, Interior(1) 32-7-10 to 37-0-6, Exterior(2E) 37-0-6 to 41-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3). Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed fora 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 2, 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 810 lb uplift at joint 2 and 810 lb uplift at joint 9. Andrew Johnson KIM. 84943 JLTek USA, Inc EL Cert 6634 16023 Swinoey Ridge Road, Chesterfield, h10 63017 Dale: September 1-4,2021 -® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not'+ a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek° is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTPII Quality Criteria, DSB-89 and SCSI Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type Qty Ply 1820 B 3CAR BILK NO HS 147880231 2866952 A07 SPECIAL 1 1 Job Reference (optional) Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Sep 13 15:11:02 2021 Page 1 ID:193QGW BBpX31R187zeOm7kz5?ad-Nx6lmQQH_xMkdKNreEW ReXeL431 wmg?3AI d6Kye?sd r1-4-Q 4-6-5 9-0-0 15-10-8 23-9-8 30.8-0 35-1-11 39-8-0 Al-0-Q 1.4.0 4-6-5 4-5-11 6-10-8 7-10.15 6-10-B 4-5-11 4-6-5 1-4.0 5x6 = 6.00 F12 3x4 = 21 2223 5 5x8 = 5x6 = 2425 26 7 ST1.5x8STP= 2x4 II 3x4= 2x4 II ST1.5x8STP= 4x6 % 3.00 12 46 Scale = 1:73.6 4-6-5 8-8.0 12-B-0 12.914 19-10-0 26-0-0 31-0-0 1- 9-8-0 39-8-0 4-6-5 4-1-11 4-0-0 0-d 14 7-1-2 6-2-0 5-0-0 4-1-11 4-6-5 Plate Offsets (X,Y)-- [2:0-3-14,Edge], [4:0-3-0,0-2-01, [6:0-4-0,0-3-0], [7:0-3-0,0-2-0], 19:0-3-14,Edge] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/dell Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.78 Vert(LL) 0.21 15-16 >745 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.50 Vert(CT) 0.17 15-16 >943 180 BCLL 0.0 Rep Stress Incr NO WB 0.57 Horz(CT) 0.03 9 n/a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix-SH Weight: 191 lb FT = 20 LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 5-7-10 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: WEBS 2x4 SP No.3 6-0-0 oc bracing: 15-16,13-15. WEDGE Left: 2x4 SP No.3, Right: 2x4 SP No.3 REACTIONS. All bearings 0-8-0 except (jt=length) 16=0-4-0, 13=0-4-0. (lb) - Max Horz 2= 212(LC 8) Max Uplift All uplift 100 lb or less at joint(s) except 2=-312(LC 10), 9=-326(LC 10), 16=-675(LC 10), 13= 703(LC 10) Max Grav All reactions 250 lb or less at joint(s) except 2=461(LC 15), 9=538(LC 16), 16=1106(LC 19), 13=1162(LC 20) FORCES. (lb),- Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-917/450, 3-4=-338/147, 4-5— 287/644, 5-6=-74/688, 6-7=-307/675, 7-8=-470/228, 8-9— 1055/524 BOT CHORD 2-18= 251/931, 17-18=-257/935, 16-17=-28/292, 15-16=-301/136, 13-15=-391/248, 12-13=0/331, 11-12= 323/894, 9-11=-317/890 WEBS 3-17=-553/413, 4-17=-39/401, 4-16=-951/598, 5-16=-787/686, 5-15=-513/208, 6-15=-487/295, 7-12=-58/372, 8-12=-542/404, 6-13= 766/671, 7-13=-961/665 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-4-0 to 2-7-10, Interior(1) 2-7-10 to 5-0-6, Exterior(2R) 5-0-6 to 12-11-10, Interior(1) 12-11-10 to 26-8-6, Exterior(2R) 26-8-6 to 34-7-10, Interior(1) 34-7-10 to 37-0-6, Extedor(2E) 37-0-6 to 41-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 2, 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 312 lb uplift at joint 2, 326 lb uplift at Andrew Johnson PE No.84943 joint 9, 675 lb uplift at joint 16 and 703 lb uplift at joint 13. JLTekUSA, Inc. RCeti 6634 9) Load case(s) 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 15, 16, 17, 18 has/have been modified. Building designer must review loads to verify that 16023SnrogleyRidge Road, CkesterGeld,b1063017 they are correct for the intended use of this truss. Date: 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). -SeDtemher 14-2021 Gontmued on page 2 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. • - Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek" is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTPII Quality Criteria, DSB-89 and BCSI Building Component 16023 Swingley Ridge Rd Safety Information Available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type City Ply 1820 B 3CAR BLK NO HS 147880231 2866952 A07 SPECIAL 1 1 Job Reference (optional) ttuuaers mrstZiource trlant Lay, t-L), Flant cny, FL - 33567, 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Sep 13 15:11:02 2021 Page 2 I D:193QG W BBpX3j RI87zeOm7kz5?ad-Nx6lmQQH_xMkdKNreEW ReXeL431 wmg?3A1 d6Kye?sd LOAD CASE(S) Standard Except: 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-4=-54, 4-7=-54, 7-10=-54, 2-17=-20, 12-17- 20, 9-12=-20 4) Dead + 0.6 C-C Wind (Pos. Internal) Case 1: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=105, 2-1.9=59, 19-20=47, 4-20=70, 4-22=70, 22-25=47, 7-25=70, 7-27=70, 27-28=47, 9-28=59, 9-10=105, 2-17=-10, 16-17=-10, 13-16=20(F=30), 12-13=-10, 9-12=-10 Horz: 1-2=-113, 2-19=-67, 19-20=-56, 4-20= 78, 7-27=78, 27-28=56, 9-28=67, 9-10=113 5) Dead + 0.6 C-C Wind (Neg. Internal) Case 1: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=3, 2-4=-41, 4-7=-41, 7-9=-41, 9-10=3, 2-17=-20, 16-17=-20, 13-16=10(F=30), 12-13=-20, 9-12=-20 Horz: 1-2- 17, 2-4=27, 7-9= 27, 9-10=17 6) Dead + 0.6 MWFRS Wind (Pos. Internal) Left: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=42, 2-4=13, 4-23=45, 23-26=26, 7-26=16, 7-9=311 9-10=21, 2-17=-10, 16-17=-10, 13-16=20(F=30), 12-13=-10, 9-12=-10 Horz: 1-2=-50, 2-4=-22, 7-9=39, 9-10=29 7) Dead + 0.6 MWFRS Wind (Pos. Internal) Right: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (pit) Vert: 1-2=21, 2-4=31, 4-21=16, 21-24=26, 7-24=45, 7-9=13, 9-10=42, 2-17=-10, 16-17= 10, 13-16=20(F=30), 12-13=-10, 9-12=-10 Horz: 1-2=-29, 2-4=-39, 7-9=22, 9-10=50 8) Dead +0.6 MWFRS Wind (Neg. Internal) Left: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-26, 2-4=-36, 4-7=-16, 7-9=5, 9-10=15, 2-17= 20, 16-17=-20, 13-16=10(F=30), 12-13=-20, 9-12= 20 Horz: 1-2=12, 2-4=22, 7-9=19, 9-10=29 9) Dead +0.6 MWFRS Wind (Neg. Internal) Right: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=15, 2-4=5, 4-7= 16, 7-9=-36, 9-10=-26, 2-17=-20, 16-17= 20, 13-16=10(F=30), 12-13=-20, 9-12= 20 Horz: 1-2=-29, 2-4=-19, 7-9=-22, 9-10- 12 10) Dead + 0.6 MWFRS Wind (Pos. Internal) 1st Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=74, 2-4=45, 4-7=45, 7-9=45, 9-10=74, 2-17=-10, 16-17=-10, 13-16=20(F=30), 12-13=-10, 9-12=-10 Horz: 1-2=-82, 2-4=-54, 7-9=54, 9-10=82 11) Dead+ 0.6 MWFRS Wind (Pos. Internal) 2nd Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=45, 2-4=16, 4-7=16, 7-9=16, 9-10=45, 2-17=-10, 16-17=10, 13-16=20(F=30), 12-13=-10, 9-12_ 10 Horz: 1-2=-53, 2-4=-25, 7-9=251 9-10=53 12) Dead + 0.6 MWFRS Wind (Neg. Internal) 1st Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2- 5, 2-4=-16, 4-7=-16, 7-9- 16, 9-10= 5, 2-17=-20, 16-17=-20, 13-16=10(F=30), 12-13=-20, 9-12= 20 Horz: 1-2=-9, 2-4=2, 7-9=-2, 9-10=9 13) Dead +0.6 MWFRS Wind (Neg. Internal) 2nd Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (pit) Vert: 1-2= 5, 2-4=-16, 4-7=-16, 7-9=-16, 9-10=-51 2-17=-20, 16-17=-20, 13-16=10(F=30), 12-13=-20, 9-12= 20 Horz: 1-2=-9, 2-4=2, 7-9=-2, 9-10=9 15) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) Left): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-53, 2-4=-61, 4-7= 45, 7-9= 30, 9-10=-221 2-17=-20, 16-17=-20, 13-16=61(F=81), 12-13=-20, 9-12=-20 Horz: 1-2=9, 2-4=17, 7-9=14, 9-10=22 16) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) Right): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-22, 2-4=-30, 4-7=-45, 7-9=61, 9-10= 531 2-17=-20, 16-17=-20, 13-16=61(F=81), 12-13=-20, 9-12=-20 Horz: 1-2=-22, 2-4=-14, 7-9=-17, 9-10=-9 17) Dead +0.75 Roof Live (bal.) +0.75(0.6 MWFRS Wind (Neg. Int) 1st Parallel): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-37, 2-4=-45, 4-7=-45, 7-9= 45, 9-10=-37, 2-17=-20, 16-17= 20, 13-16=61(F=81), 12-13=-20, 9-12=-20 Horz: 1-2=-7, 2-4=1, 7-9=-1, 9-10=7 18) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) 2nd Parallel): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2= 37, 2-4=-45, 4-7=-45, 7-9=-45, 9-10=-37, 2-17=-20, 16-17=-20, 13-16=61(F=81), 12-13=-20, 9-12= 20 Horz: 1-2- 7, 2-4=1, 7-9=-1, 9-10=7 ®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. ' - Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI1TPI1 Quality Criteria, DSB-89 and BCSI Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 ' Job Truss Truss Type City Ply 1820 B 3CAR BLK NO HS 147880232 2866952 A08 SPECIAL 1 1 Job Reference (optional) Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Sep 13 15:11:04 2021 Page 1 I D:193QG W BBpX3j Rl87zeOm7kz5?ad-KJE2B6RXVYcSseXDmfyvjyjgJtdU EUcMdLKpACye?sb 1-4-q 7.0-0 12-3-1 16-0-8 19.10-0 22-5-14 26-3-5 32.8.0 39-8-0 t11-0•Q 1-4.0 7-0-0 13. -_8 3-9.8 2-7-14 3-9.8 6.4-11 7-0-0 1-4-0 5x6 = 6.00 F12 Scale=1:73.6 3x8 = 3x4 = 2x4 11 5x6 = 5x12 = 5x6 — 18 19 4 2021 22 5 23 246 25 7 26 827 28 29 9 ST1.5x8 STP = ST1.5x8 STP = 3x6 % 3x8 = 3.00 F12 5x6 THIS TRUSS IS NOT SYMMETRIC. PROPER ORIENTATION IS ESSENTIAL. 7-1-8 12-3-1 12 -0 19-10-0 26-2-0 26 -5 32.6-8 39-8.0 7-1-8 5.1.9 0- -15 7-4.0 6-4-0 0- -5 6-3.3 7-1-8 Plate Offsets (X,Y)-- [2:0-0-10,Edge], [3:0-3-0,0-2-0], [4:0-3-8,0-1-8], [7:0-3-0,0-3-0], [8:0-3-8,0-2-8], [9:0-4-0,0-2-8], [10:0-4-7,Edge], [12:0-8-0.0-0-8], [13:0-3-8,0-3-0], [1 6:0-3-8,0-3-01,[17:0-5-8,0-0-8] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.86 Vert(LL) 0.24 14-16 >709 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.87 Vert(CT) -0.27 14-16 >635 180 BCLL 0.0 Rep Stress Incr NO WB 0.94 Horz(CT) 0.07 10 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix-SH Weight: 179 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 *Except* TOP CHORD Structural wood sheathing directly.applied or 3-2-6 cc puffins. 7-9: 2x4 SP No.1 BOT CHORD Rigid ceiling directly applied or 5-2-7 cc bracing. BOT CHORD 2x4 SP No.2 WEBS 1 Row at midpt 8-12 WEBS 2x4 SP No.3 WEDGE Right: 2x4 SP No.3 REACTIONS. All bearings 0-8-0 except Qt=length) 16=0-4-0, 13=0-4-0. (lb) - Max Horz 2=-171(LC 6) Max Uplift All uplift 100 lb or less at joint(s) except 2= 362(LC 8), 10=-445(LC 8), 16=-1709(LC 8), 13— 1849(LC 8) Max Grav All reactions 250 lb or less at joint(s) except 2=602(LC 1), 10=700(LC 1), 16=2275(LC 1), 13=2378(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1151/341, 3-4=-933/356, 4-5=-632/1043, 5-6= 775/1231, 6-7=-775/1231, 7-8=-706/1076, 8-9=-1294/649, 9-10=-1549/671 BOT CHORD 2-17=-205/984, 16-17— 1043/843, 14-16=-548/221, 13-14=-465/179, 12-13=-1077/936, 10-12= 455/1346 WEBS 3-17=-147/318, 4-16=-1312/942, 5-16=-1420/1451, 5-14=-610/696, 6-14=-420/437, 7-14— 761/737, 7-13=-1411/1476, 8-13=-1431/1132, 9-12=-46/367, 4-17=-1025/2111, 8-12= 1408/2480 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof jive load -shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ` This truss has been designed for a jive load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 2, 10 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. Andrew JolmsonPE No. 84943 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 362 lb uplift at joint 2, 445 lb uplift at 1111ekUSX Inc. FLCerl6634 joint 10, 1709 lb uplift at joint 16 and 1849lb uplift at joint 13. 16023StsingleyRidgeRoad, ChesterGeld,Sf063017 9) Load case(s) 4, 5, 6, 7, 8, 9, 10, 11, 13, 14, 15, 16 has/have been modified. Building designer must review loads to verify that they Date: are correct for the intended use of this truss. September 14,2021 Continued on page 2 0 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE.__ - `'Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not'• a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVrPI1 Quality Criteria, DSB-89 and BCSI Building Component 16023 Swingiey Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf; MD 20601 Chesterfield, MO 63017 Job Truss Truss Type Qty Ply 1820 B 3CAR ELK NO HS 147680232 2866952 AOB SPECIAL 1 1 Job Reference (optional) builders FirstSource (I lant City, FL), Plant City, FL - 33567, 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Sep 13 15:11:04 2021 Page 2 ID:193QGW BBpX3jRI87zeOm7kz5?ad=KJE2B6RXVYcSseXDmfYvjyjgJtdUEUcMdLKpACye?sb NOTES- 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 175 lb down and 159 lb up at 7-0-0, 111 lb down and 197 lb up at 9-0-12, 111 lb down and 197 lb up at 11-0-12, 111 lb down and 197 Ib up at 13-0-12, 111 lb down and 197 lb up at 15-0-12; 111 lb down and 197 lb up at 17-0-12, 111 lb down and 197 lb up at 19-0-12, 111 lb down and 197 lb up at 20-7-4, 111 lb down and 197 lb up at 22-7-4, 111 lb down and 197 lb up at 24-7-4, 111 lb down and 197 lb up at 26-7-4, 111 lb down and 197 lb up at 28-7-4, and 111 lb down and 197 lb up at 30-7-4, and 175 lb down and 356 lb up at 32-8-0 on top chord, and 353 lb down and 128 lb up at 7-1-12, 92 lb down at 9-0-12, 92 lb down at 11-0-12, 92 lb down at 13-0-12, 92 lb down at 15-0-12, 92 lb down at 17-0-12, 92-lb down at 19-0-12, 92 lb down at 20-7-4, 92 lb down at 22-7-4, 92 lb down at 24-7-4, 92 lb down at 26-7-4, 92 lb down at 28-7-4, and 92 lb down at 30-7-4, and 353 lb down and 128 lb up at 32-6-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 3-9- 54, 9-11= 54, 2-17=-20, 12-17= 20, 10-12= 20 Concentrated Loads (lb) Vert: 3=-175(B)7=-111(B) 9=-175(B)17=-330(B)15=-46(B)12=-330(B)18=-111(B)19- 111(13) 20=-111(B) 22=-1 11 (B) 23=-1 11 (B) 24=-1 11 (B) 25=-1 11 (B) 26= 111(B) 27=-111(B) 28=-111(6) 29=-111(13) 30=-46(B) 31= 46(B) 32= 46(B) 33=-46(B) 34=-46(B) 35=-46(B) 36= 46(B) 37=-46(B) 38=-46(B) 39=-46(B) 40=-46(B) 4) Dead +0.6 MWFRS Wind (Pos. Internal) Left: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (pit) Vert: 1-2=42, 2-3=13, 3-21=45, 21-28=26, 9-28=16, 9-10=31, 10-11=21, 2-17=-10, 16-17=-10, 13-16=49(F=59), 12-13=-10, 10-12= 10 Horz: 1-2= 50, 2-3=-22, 9-10=39, 10-11=29 Drag: 3-4=-0, 8-28=0, 9-28=0 Concentrated Loads (lb) Vert: 3=130(B) 7=156(B) 9=257(B) 17=108(B) 15=-23(B) 12=108(B) 18=136(B) 19=136(B) 20=136(B) 22=156(B) 23=156(B) 24=156(B) 25=156(B) 26=156(B) 27=156(B) 28=156(0) 29=165(B) 30=-23(B) 31=-23(B) 32=-23(B) 33=-23(B) 34=-23(B) 35=-23(B) 36=-23(B) 37=-23(B) 38=-23(B) 39= 23(B)40=-23(B) 5) Dead +0.6 MWFRS Wind (Pos. Internal) Right: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=21, 2-3=31, 3-19=16, 8-19=26, 8-9=45, 9-10=13, 10-11=42, 2-17= 10, 16-17=-10, 13-16=49(F=59), 12-13=-10, 10-12=-10 Horz: 1-2=-29, 2-3=-39, 9-10=22, 10-11=50 Drag: 3-19=-0, 4-19=-0, 8-9=0 Concentrated Loads (lb) Vert: 3=159(B) 7=156(B) 9=246(B) 17=108(B) 15= 23(B) 12=108(B) 18=165(B) 19=156(B) 20=156(B) 22=156(B) 23=156(B) 24=156(B) 25=156(B) 26=156(B) 27=136(B) 28=136(B) 29=136(B) 30=-23(B) 31=-23(B)32= 23(B)33=-23(B)34=-23(8)35=-23(B)36=-23(B) 37=-23(B) 38=-23(B)39=-23(B)40= 23(B) 6) Dead +0.6 MWFRS Wind (Neg. Internal) Left: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-26, 2-3= 36, 3-9=-16, 9-10=5, 10-11=15, 2-17- 20, 16-17= 20, 13-16=39(F=59), 12-13=-20, 10-12=-20 Horz: 1-2=12, 2-3=22, 9-10=19, 10-11=29 Concentrated Loads (lb) Vert: 3=54(B)7=197(B)9=315(B)17=128(B)15=-13(B)12=128(B)18=197(B)19=197(B)20=197(B)22=197(B)23=197(B)24=197(B)25=197(B)26=197(B) 27=197(B) 28=197(B) 29=197(B) 30=-13(B) 31- 13(B) 32=-13(B) 33_ 13(B) 34- 13(B) 35=-13(B) 36=-13(B) 37=-13(B) 38=-13(B) 39=-13(8) 40=-13(B) 7) Dead +0.6 MWFRS Wind (Neg. Internal) Right: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=15, 2-3=5, 3-9=-16, 9-10=-36, 10-11=-26, 2-17=-20, 16-17=-20, 13-16=39(F=59), 12-13=-20, 10-12=-20 Horz: 1-2=-29, 2-3=-19, 9-10=-22, 10-11=-12 Concentrated Loads (lb) Vert: 3=54(B) 7=197(B) 9F=356(B) 17=128(B) 15=-13(B) 12=128(B) 18=197(B) 19=197(B) 20=197(B) 22=197(B) 23=197(B) 24=197(B) 25=197(B) 26=197(B) 27=197(B) 28=197(B) 29=197(B) 30=-13(B) 31=-13(B) 32=-13(B) 33=-13(B) 34=-13(B) 35=-13(B) 36=-13(B) 37=-13(B) 38=-13(B) 39- 13(B) 40- 13(B) 8) Dead+ 0.6 MWFRS Wind (Pos. Internal) 1st Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=74, 2-3=45, 3-9=45, 9-10=45, 10-11=74, 2-17=-10, 16-17=-10, 13-16=49(F=59), 12-13=-10, 10-12=-10 Horz: 1-2- 82, 2-3=-54, 9-10=54, 10-11=82 Drag: 3-4=-0, 8-9=0 Concentrated Loads (lb) Vert: 3=130(B) 7=136(B) 9=214(B) 17=108(B) 15=-23(B) 12=108(B) 18=136(B) 19=136(B) 20=136(B) 22=136(B) 23=136(B) - 24=136(B) 25=136(B) 26=136(B) 27=136(B) 28=136(B) 29=136(B) 30=-23(B) 31- 23(B)-32= 23(B)33=-23(B) 34=-23(B) 35=-23(B) 36= 23(B) 37=-23(B) 38=-23(B) 39=-23(B) 40=-23(B) 9) Dead +0.6 MWFRS Wind (Pos. Internal) 2nd Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=45, 2-3=16, 3-9=16, 9-10=16, 10-11=45, 2-17=-10, 16-17=-10, 13-16=49(F=59), 12-13=-10, 10-12=-10 Horz: 1-2=-53, 2-3=-25, 9-10=25, 10-11=53 Drag: 3-4=-0, 8-9=0 Concentrated Loads (lb) Vert: 3=116(B) 7=165(B) 9=271(B) 17=108(B) 15=-23(B) 12=108(B) 18=165(B) 19=165(B) 20=165(B) 22=165(B) 23=165(B) 24=165(B)25=165(B) 26=165(B) 27=165(B) 28=165(B) 29=165(B) 30=-23(B) 31=-23(B) 32=-23(B) 33=-23(B) 34=-23(B) 35=-23(B) 36=-23(B) 37= 23(B)38=-23(B)39= 23(B)40=-23(B) 10) Dead + 0.6 MWFRS Wind (Neg. Internal) 1st Parallel: Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-5, 2-3=-16, 3-9= 16, 9-10=-16, 10-11=-5, 2-17=-20, 16-17=-20, 13-16=39(F=59), 12-13=-20, 10-12= 20 Horz: 1-2=-9, 2-3=2, 9-10= 2, 10-11=9 Concentrated Loads (lb) Vert: 3=72(B) 7=197(B) 9=335(B) 17=128(B) 15=-13(B) 12=128(B) 18=197(B) 19=197(B) 20=197(B) 22=197(B) 23=197(B) 24=197(B)25=197(B) 26=197(B) 27=197(B) 28=197(B) 29=197(B) 30=-13(B) 31=-13(B) 32=-13(B) 33=-13(B) 34=-13(B) 35=-13(B) 36=-13(13) 37- 13(B) 38=-13(B) 39=-13(B) 40=-13(B) 11) Dead + 0.6 MWFRS Wind (Neg. Internal) 2nd Parallel: Lumber Increase=1.60, Plate Increase=1.60 Continued on page 3 ® WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. - Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTP11 Quality Criteria, DSB-89 and BCSI Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MD 63017 Job Truss Truss Type Qty Ply 1820 B 3CAR BLK NO HS 147880232 2866952 A08 SPECIAL 1 1 - -- Job Reference (optional) timaers t-irstz)ource triant i ity, rL), mant arty, rl_ - 33b67, 8.430 s Aug 16 2021 MI I eK Industries, Inc. Mon Sep 13 15:11:04 2021 Page 3 - ID:193QGWBBpX3jR187zeOm7kz5?ad-KJE2B6RXVYcSseXDmfYvjyjgJtdUEUcMdLKpACye?sb LOAD CASE(S) Standard Uniform Loads (plf) Vert: 1-2=-5, 2-3=-16, 3-9- 16, 9-10=-16, 10-11=-5, 2-17= 20, 16-17=-20, 13-16=39(F=59), 12-13= 20, 10-12=-20 Horz: 1-2=-9, 2-3=2, 9-10=-2, 10-11=9 Concentrated Loads (lb) Vert: 3=72(B)7=197(B)9=335(B)17=128(B)15=-13(B)12=128(B)18=197(B)19=197(B)20=197(B)22=197(B)23=197(B)24=197(B)25=197(B)26=197(B) 27=197(B) 28=197(B) 29=197(B) 30=-13(B) 31=-13(B) 32- 13(B) 33=-13(B) 34=-13(B) 35=-13(B) 36=-13(B) 37= 13(B) 38=-13(B) 39- 13(B) 40=-13(B) 13) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) Left): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-53, 2-3=-61, 3-9- 45, 9-10=-30, 10-11=-22, 2-.17=-20, 16-17=-20, 13-16=24(F=44), 12-13=-20, 10-12=-20 Horz: 1-2=9, 2-3=17, 9-10=14, 10-11=22 Concentrated Loads (lb) Vert: 3=-19(B) 7=145(B) 9=232(B) 17=76(B) 15=-13(B) 12=76(B) 18=145(B) 19=145(B) 20=145(B) 22=145(B) 23=145(B) 24=145(B) 25=145(B) 26=145(B) 27=145(B) 28=145(B) 29=145(B) 30=-13(B) 31=-13(B) 32= 13(B) 33=-13(B) 34=-13(B) 35=-13(B) 36=-13(B) 37=-13(B) 38=-13(B) 39=-13(B) 40= 13(B) 14) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) Right): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-22, 2-3=-30, 3-9=-45, 9-10=-61, 10-11=-53, 2-17= 20, 16-17=-20, 13-16=24(F=44), 12-13- 20, 10-12=-20 Horz: 1-2=-22, 2-3= 14, 9-10=-17, 10-11=-9 Concentrated Loads (lb) Vert: 3=-19(B) 7=145(b) 9=262(B) 17=76(B) 15=-13(B) 12=76(B) 18=145(B) 19=145(B) 20=145(B) 22=145(B) 23=145(B) 24=145(B) 25=145(B) 26=145(B) 27=145(B) 28=145(B) 29=145(B) 30=-13(B) 31=-13(B) 32=-13(B) 33=-13(B) 34= 13(B) 35= 13(B) 36=-13(B) 37- 13(B) 38=-13(B) 39=-13(B) 40=-13(B) 15) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) 1st Parallel): Lumber Increase=1.60, Plate Increase=1.60 _ Uniform Loads (plf) Vert: 1-2=-37, 2-3=-45, 3-9=-45, 9-10=-45, 10-11=-37, 2-17=-20, 16-17=-20, 13-16=24(F=44), 12-13=-20, 10-12=-20 Horz: 1-2= 7, 2-3=1, 9-10=-11 10-11=7 Concentrated Loads (lb) Vert: 3=-5(B) 7=145(B) 9=247(B) 17=76(B) 15=-13(B) 12=76(B) 18=145(B) 19=145(B) 20=145(B) 22=145(B) 23=145(B) 24=145(B) 25=145(B) 26=145(B) 27=145(B) 28=145(B) 29=145(B) 30=-13(B) 31=-13(B) 32=-13(B) 33=-13(B) 34=-13(B) 35=-13(B) 36=-13(B) 37- 13(B) 38=-13(B) 39=-13(B) 40=-13(B) 16) Dead + 0.75 Roof Live (bal.) + 0.75(0.6 MWFRS Wind (Neg. Int) 2nd Parallel): Lumber Increase=1.60, Plate Increase=1.60 Uniform Loads (plf) Vert: 1-2=-37, 2-3=-45, 3-9=-45, 9-10= 45, 10-11=-37, 2-17=-20, 16-17=-20, 13-16=24(F=44), 12-13=-20, 10-12=-20 Horz: 1-2=-7, 2-3=1, 9-10=-1, 10-11=7 Concentrated Loads (lb) Vert: 3=-5(B)7=145(B)9=247(B)17=76(B)15=-13(B)12=76(B)18=145(B)19=145(B)20=145(B)22=145(B)23=145(B)24=145(B)25=145(B)26=145(B) 27=145(B) 28=145(B) 29=145(B) 30=-13(B) 31=-13(B) 32=-13(B) 33=-13(B) 34=-13(B) 35=-13(B) 36=-13(B) 37=-13(B) 38=-13(B) 39=-13(B) 40=-13(B) Q WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, note a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek° is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTP11 Quality Criteria, DSB-69 and SCSI Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type Qty Ply 1820 B 3CAR BLK NO HS 147880233 2866952 A09- SPECIAL 1 1 - Job Reference (optional) Builders PtrstSource (Plant City, FL), Plant City, FL - 33567, 6-8-0 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon I D:193QG W BBpX3j Rl87zeOm7kz5?ad-Gi MocoTn1 As95xgct- o-p 23-10-0 26-8-0 31.0.0 33-0.0 39-8 2•d 2-10-0 2-10-0 4.4-0 2-0.0 6-8- 13 15:11:06 2021 Page 1 Scale=1:76.6 cc 171;i- 5x6 = 3x6 = 5x6 7 7x8 ST1.5x8 STP = ST1.5x8 STP = 6x8 = 3.00 F12 6x8 LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC2020/TPI2014 CSI. TC 0.89 BC 0.93 WB 0.76 Matrix-SH DEFL. in (loc) I/dell Ud Vert(LL) 0.55 15-17 >848 240 Vert(CT) -0.90 15-17 >521 180 Horz(CT) 0.57 11 n/a n/a PLATES GRIP MT20 244/190 Weight: 207lb FT=20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 *Except* TOP CHORD Structural wood sheathing directly applied. Except: 3-4,8-10: 2x4 SP M 31, 1-3,10-12: 2x4 SP No.i 1 Row at micipt 6-8 BOT CHORD 2x4 SP No.2 *Except* BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. f 2-18,11-13: 2x4 SP No.1 WEBS 2x4 SP No.3 WEDGE Left: 2x4 SP No.3 , Right: 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 11=0-8-0 Max Horz 2=351(LC 9) Max Uplift 2=-810(LC 10), 11=-810(LC 10) Max Grav 2=1533(LC 1), 11=1533(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-4720/2891, 3-4=-4465/2748, 4-5=-2921/1929, 5-6=-2908(1848, 6-8=-2747/1725, 8-9= 3092/1920, 9-10=-4489/2594, 10-11=-4691/2667 BOT CHORD 2-18=-2503/4403, 17-18=-1451/2727, 15-17=-1651/3095, 14-15=-1331/2738, 13-14=-1975/3908, 11-13=-2229/4190 WEBS 3-18=-279/338, 4-18=-989/1877, 4-17=-98/473, 5-17=-332/223, 5-15=-422/342, 8-15=-195/501, 8-14=-352/676, 9-14=-1317/724, 9-13=-564/1195 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-4-0 to 2-7-10, Interior(1) 2-7-10 to 9-0-6, Exterior(2R) 9-0-6 to 16-11-10, Interior(1) 16-11-10 to 21-0-7, Extedor(2R) 21-0-7 to 23-10-0, Exterior(2E) 23-10-0 to 26-4-1, Interior(1) 26-4-1 to 37-0-6, Exterior(2E) 37-0-6 to 41-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer/ Project engineer responsible forverifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 2, 11 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. AndrereJohmonPENo.84943 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 810 lb uplift at joint 2 and 810 lb uplift at Mlek USA, Inc. R Ced 6634 joint 11.16013Sningle3BidgeRoad, Chesterfield, MID 63017 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. Date: September 14,2021 Q WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. - Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and propedy incorporate this design into the overall building design. Bracing indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTPII Quality Criteria, DSB-89 and BCSI Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type Qty Ply 1820 B 3CAR BLK NO HS 147880234 2866952- A10 SPECIAL 1 1 Job Reference (optional) Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Sep 13 15:11:08 2021 Page 1 I D:193QGW BBpX3jR187zeOm7kz5?ad-05TZ1 TU2Zn6tLFq_?VdruouMpU?YANi yYzlOJzye?sX r1-4-q 5-11-1 11-0-0 16-10-1 19.0-0 22-9-15 2�-10r0 28-8.0 31-0-0 33.8-15 39.8-0 ¢1-0 q '1-4-0' 5.11-1 5-0-15 5-10-1 2-1.15 3-9.15 0- 4-10.0 2-4.0 2-8-15 5-11-1 1-4.0 Scale=1:76.6 5x6 = 10x12 ST1.5x8 STP = ST1.5x8 STP = 6x8 3.00 12 6x8 zz 8-2-11 5-10-11 15-10-11 ' 2-4-0 LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC2020/TPI2014 CSI. TC 0.89 BC 0.87 WB 0.53 Matrix-SH DEFL. Vert(LL) Vert(CT) Horz(CT) in (loc) I/dell Ud 0.59 17-19 >787 240 -0.86 17-19 >545 180 0.54 13 n/a n/a PLATES GRIP MT20 244/190 Weight: 248 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 `Except* TOP CHORD Structural wood sheathing directly applied. Except: 4-7,7-10: 2x6 SP No.2 1 Row at midpt 7-10 BOT CHORD 2x6 SP No.2 *Except* BOT CHORD Rigid ceiling directly applied or 3-10-1 oc bracing. 2-20,13-15: 2x4 SP No.1 JOINTS 1 Brace at Jt(s): 7 WEBS 2x4SPNo.3 WEDGE Left: 2x4 SP No.3 , Right: 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 13=0-8-0 Max Horz 2=-352(LC 8) Max Uplift 2=-81 O(LC 10), 13=-810(LC 10) Max Grav 2=1533(LC 1), 13=1533(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-4678/3031, 3-4=-4481/2851, 4-5= 4120/2767, 5-6=-4119/2766, 6-7— 3604/2457, 7-9= 3232/2194, 9-10= 3236/2197, 10-11=-3578/2300, 11-12= 4480/2710, 12-13=-4650/2812,-6-8=-621/451, 8-10=-629/457 BOT CHORD 2-20=-2613/4354, 19-20=-1856/3221, 17-19=-2133/3758, 16-17=-1683/3159, 15-16=-2105/3917, 13-15=-2362/4148 WEBS 3-20=-173/277, 4-20=-733/1482, 4-19=-609/1078, 5-19=-577/514, 7-19=-287/570, 7-17=-334/335, 10-17=-517/825, 8-9=-62/281, 10-16=-457/937, 11-16=-1042/581, 11 - 1 5=-484/1009 NOTES- 1) Unbalanced roof live loads have been considered for this design. -2) Wind: ASCE-7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-4-0 to 2-7-10, Interior(1) 2-7-10 to 7-0-6, Exterior(2R) 7-0-6 to 14-11-10, Interior(1) 14-11-10 to 19-10-6, Exterior(2R) 19-10-6 to 27-9-10, Interior(1) 27-9-10 to 37-0-6, Exterior(2E) 37-0-6 to 41-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer/ Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 2, 13 considers parallel to grain value using ANSUTPI 1 angle to grain formula. Building designer should Verify Andrew JohnsonPENo.84943 capacity of bearing surface. %U1ekUSA Inc.RCert6634 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 810 Ib uplift at joint 2 and 810 lb uplift at 16023 SuiogleyRidge Road, Chesterfield,11063017 joint 13., Date: 9)-Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. September 14,2021 ® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek` is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVrPI1 Quality Criteria, DSB-89 and BCSI Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type Oty Ply 1820 B 3CAR BLK NO HS 147880235 2866952 A11B SPECIAL 1 1 Job Reference (optional) Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Sep 13 15:11:11 2021 Page 1 ST 1.5x8 STP = 5x6 3.00 12 5x6 = 13 12 46 = 3x6 = 6x8 = Scale=1:71.9 3x6 = 8-8-0 14-9-4 6.8-4 0.0-8 9-4-4 10-1-12 Plate Offsets (X,Y)-- [2:0-5-6,Edge], [4:0-4-0,0-2-8], [8:0-4-0,0-3-01, [12:0-3-8,0-3-0] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.96 Vert(LL) -0.26 10-12 >864 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.93 Vert(CT) -0.42 2-16 >575 180 BCLL 0.0 Rep Stress Incr YES WB 0.90 Horz(CT) -0.03 12 n/a n/a BCDL 10.0 Code FBC202OTrP12014 Matrix-SH Weight: 196 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied. BOT CHORD 2x4 SP No.2 `Except` BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. Except: 6-12: 2x4 SP No.3, 9-11: 2x4 SP No.1 3-3-0 oc bracing: 12-14 WEBS 2x4 SP No.3 WEBS 1 Row at midpt 7-12 REACTIONS. (size) 2=0-8-0, 12=0-4-0, 9=Mechanical Max Horz 2=343(LC 9) Max Uplift 2=-502(LC 10), 12= 633(LC 10), 9=-359(LC 10) Max Grav 2=916(LC 15), 12=1774(LC 15), 9=911(LC 16) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2273/1422, 3-4=-1990/1254, 4-5=-1271/860, 5-6=-236/288, 6-7= 195/352, 7-8=-1209/755, 8-9= 1335/709 BOT CHORD 2-16=-1213/2282, 15-16=-861/1814, 14-15=-460/751, 12-14=-1004/700, 9-10=-495/1112 WEBS 3-16=-273/281, 4-16=-346/880, 4-15=-497/321, 5-15=-1501777, 5-14=-10391794, 7-12=-675/290, 7-10=-481/1112, 8-10=-507/509 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-4-0 to 2-7-10, Interior(1) 2-7-10 to 5-0-6, Exterior(2R) 5-0-6 to 12-11-10, Interior(1) 12-11-10 to 19-10-6, Exterior(2R) 19-10-6 to 27-9-10, Interior(1) 27-9-10 to 35-4-6, Exterior(2E) 35-4-6 to 39-4-0 zone;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = I O.Opsf. 7) Refer to girder(s) for truss to truss connections. 8) Bearing at joint(s) 2 considers parallel to grain value using ANSI/fPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 502 lb uplift at joint 2, 633 lb uplift at joint 12 and 359 lb uplift at joint 9. Andrew Johnson PE So. 84943 3hTek USA, Inc. £L Cer16634 16013 Sniugley Ridge Road, Chesterfield, MO 63017 Dale: September-14,2021 Y A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. "Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall'• building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTP11 Quality Criteria, DSB-89 and BCSI Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type Oily I Ply 1820 B 3CAR BLK NO HS 147880236 2866952 Al2B SPECIAL 1 1 Job Reference (optional) Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Sep 13 15:11:13 2021 Page 1 I D:3xt?Yd6RbYnXO16Sf6ghjjz4cnz-Z2HS4BYBOJIAROjyn2DObsbD2Vgxrbuhi EOn_Bye?sS 1-4-q 7.0-0 9-2-2 12-8-0 15-0-0 17-1-13 20-1-8 22.4-0 , 25-4.0 31-0-2 35-4-2 39-8-0 11 7.0-0 2-2-2 3-5-14 2-4.0 2-1-13 2-11-11 2-2-8 3-0-0 5-8-2 4-3-15 4-3-14 5x6 = 4x4 5x6 = 27 10 Scale=1:72.3 0 0 m N fa 0 ST1.5x8 STP = 8x12 = 1817 16 3x6 = 5x6 48 = 3x6 = 3x6 = 3x8 1\ 3.00 12 6x8 = 7-1-8 Plate Offsets_(X,Y)-- [2:0-1-15,1-2-13], [2:0-5-6,Edge], [3:0-6-0 0-2-8] [9:0-3-0,0-2-7], [10:0-3-0,0-2-0], [11:0-3-0,0-3-0], [21:0-3-0,0-4-0] [24:0-4-0,0-1-12] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Well Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.86 Vert(LL) 0.22 23 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.98 Vert(CT) -0.31 2-24 >776 180 BCLL 0.0 * Rep Stress Incr NO WB 0.75 Horz(CT) -0.03 17 n/a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix-SH Weight: 239 lb FT = 20 LUMBER- BRACING - TOP CHORD 2x4 SP No.2 *Except* TOP CHORD Structural wood sheathing directly applied or 2-5-1 oc purlins. 1-3: 2x4 SP No.1 BOT CHORD Rigid ceiling directly applied or 5-0-12 oc bracing. Except: BOT CHORD 2x4 SP No.2 *Except* 6-0-0 oc bracing: 17-19 5-22: 2x8 SP 240OF 2.OE, 19-21,8-17: 2x6 SP M 26 WEBS 1 Row at midpt 9-17 WEBS 2x4 SP No.3 WEDGE Left: 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 17=0-4-0, 13=Mechanical Max Horz 2=313(LC 7) Max Uplift 2=-658(LC 8), 17=-1041(LC 8), 13=-233(LC 8) Max Grav 2=1126(LC 1), 17=2295(LC 1), 13=666(LC 14) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOP CHORD 2-3=-3150/1523, 3-4=-2617/1413, 4-5=-2431/1366, 5-6=-2711/1506, 6-7— 391/396, 7-8=-372/1166, 8-9=-180/815, 9-10=-357/165, 10-11=-386/235, 11-12=-966/332, 12-13— 1103/379 BOT CHORD 2-24=-1274/2787, 23-24=-1249/2762, 22-23=-684/1374, 5-21=-254/253, 20-21=-473/889, 19-20=-274/175, 17-19=-1208/740, 8-19=-414/311, 16-17= 485/358, 14-16=-92/633, 13-14= 269/925 WEBS 3-24=-383/1134, 3-23=-285/85, 21-23=-551/1271, 6-21=-909/1964, 6-20=-1205/723, 7-20= 616/1259, 7-19=-932/550, 9-17=-1195/401, 10-16=-331/164, 11-16=-597/385, 11-14=-73/382, 9-16=-372/884 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASIDE 7-16; Vuit=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Bearing at joint(s) 2 considers parallel to grain value using ANSI/rPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 9) Provide mechanical -connection (by others) of truss to bearing plate capable of withstanding 658 lb uplift at joint 2, 1041 lb uplift at joint 17 and 233 lb uplift at joint 13. Continued on page 2 Andress Johnson PE No. 84943 MiTek USA, Inc FL Ced 6634 14023 Sofugley Ridge Road, Chesterfield, SID 63017 Date: September 14,2021 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. �T '- ` Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not• a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTPII Quality Criteria, DSB-89 and BCSI Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type Qty Ply 1820 B 3CAR BLK NO HS 147880236 2866952 Al2B SPECIAL 1 1 Job Reference (optional) Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Sep 13 15:11:13 2021 Page 2 I D:3xt7Yd6RbYnXO16Sf6ghjjz4cnz-Z2HS4BYBOJIAROjyn2DObsbD2Vgxrbuhi EOn—Bye7sS NOTES- 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 179 lb down and 164 lb up at 7-0-0, and 115 lb down and 182 lb up at 9-0-12, and 115 lb down and 182 lb up at 11-0-12 on top chord, and 343 lb down and 129 lb up at 7-1-8, and 81 lb down at 9-0-12, and 81 lb down at 11-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 3-6=-54, 6-9=-54, 9-10= 54, 10-13=-54, 2-24=-20, 22-24=-20, 19-21= 20, 17-18= 20, 13-17=-20 Concentrated Loads (lb) Vert: 3=-1 79(F) 24=-343(F) 23=-59(F) 4=-115(F) 25=-115(F) 28=-59(F) ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. " Dbsign valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not '• a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall , building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTP11 Quality Criteria, DSB-89 and BCSI Building Component 16023 Swingley Ridge Rd , Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type City Ply 1820 B 3CAR BLK NO HS 147880237 2866952 B02B SPECIAL 1 1 Job Reference (optional) Bullcers FirsiSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Sep 13 15:11:15 2021 Page 1 ID:3xt?Yd6RbYnXO16Sf6ghjjz4cnz-VRPCVsaRww?ugKsLvTFUgHhZi JPgJUg-9YVu33ye?sQ 4-10-5 8-1-8 9.0-0 14-8-0 21-1-2 27-8.0 4-10-5 3-3-3 10- 5-8-0 6-5-2 6.6.14 6x8 11 3x4 = Sx8 = 3 4 17 11 9 8 126x8 = 46 = 3x4 = 2x4 II 3x4 14.8-0 4- Scale = 1:49.0 LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FB02020/TP12014 CS1. TC 0.82 BC 0.71 WB 0.79 Matrix-SH DEFL. in Vert(LL) 0.22 Vert(CT) 0.19 Horz(CT) -0.03 (loc) I/defi Ud 7-8 >999 240 7-8 >999 180 7 n/a n/a PLATES GRIP MT20 244/190 Weight: 153lb FT=20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 5-1-4 oc purlins. BOT CHORD 2x4 SP No.2 `Except` BOT CHORD Rigid ceiling directly applied or 3-11-1 oc bracing. Except: 1-13: 2x6 SP No.2, 3-11: 2x6 SP M 26 6-0-0 oc bracing: 11-13 WEBS 2x4 SP No.3 WEBS 1 Row at midpt 5-9, 5-11 REACTIONS. (size) 11=0-4-0, 7=Mechanical Max Horz 11=229(LC 9) Max Uplift 11=-1447(LC 10), 7=-567(LC 10) Max Grav 11=1618(LC 18), 7=748(LC 16) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-2= 749/416, 2-3=-1238/703, 3-4= 394/292, 4-5=-548/397, 5-6=-476f782, 6-7=-1146/1838 BOT CHORD 1-14=-332f734, 13-14=-332f734, 11-13=-823/1652, 3-13=-563/902, 9-11=-388/363, 8-9=-15271942,7-8=-1527/942 WEBS 2-13=-321f706, 5-9=-1385/619, 5-11= 1052/1982, 6-8=-682/274, 6-9=-778/1311, 2-14=-315/141 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASIDE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) 0-0-0 to 3-11-10, Interior(1) 3-11-10 to 5-0-6, Exterior(2R) 5-0-6 to 18-7-10, Interbr(1) 18-7-10 to 23-4-6, Exterior(2E) 23-4-6 to 27-4-0 zone; cantilever left exposed ; end vertical left exposed; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer/ Project engineer responsible forverifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1447 lb uplift at joint 11 and 567 lb uplift at joint 7. AndrelrJohnson PE No.84943 MiTek USA, Inc. FL Ceti 6634 16013 Slagle}' Ridge Road, Chesterfield, J10 63017 Date: September 14,2021 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/1912020 BEFORE USE. ' Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTPII Quality Criteria, DSB-89 and BCSI Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type Qty Ply 1820 B 3CAR BLK NO HS 147880238 2866952- B03B SPECIAL 1 1 — Job Reference (optional) Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Sep 13 15:11:18 2021 Page 1 ID:3xt?Yd6RbYnXO16Sf6ghjjz4cnz-vO4L7ucJCrNTXnbvabpBlvl4L-W SgWtMQrWj YgOye?sN 7-0-0 -10- 12-3-0 16-8-0 21-3-6 27.8-0 7-0.0 -10- 4-5-0 4.5.0 4-7-6 6-4-10 6.00 112 4x6 = 2x4 II 3x4 = 3 4 15 5 16 17 4x4 = Scale=1:47.1 10 4x6 = 3x8 = 2x4 I I :sx4 ST1.5x8 STP = 6x8 = 1-1-2 1-0-0 4-0-0 7-8-0 7- Q-0 16-8-0 21-3-6 27-8-0 1-0-0 2-10-14 3-B-0 0 0 8-10-0 4-7-6 6-4-10 0-1-2 Plate Offsets (X,Y)-- [1:0-0-15,0-2-0] [3:0-3-4,0-2-0], [8:0-2-10,0-1-8], [12:0-3-8,0-3-0] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.82 Vert(LL) 0.17 1-14 >546 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.68 Vert(CT) 0.15 1-14 >625 180 BCLL 0.0 Rep Stress Incr YES WB 0.67 Horz(CT) -0.03 12 n/a n/a BCDL 10.0 Code FBC2020fTPI2014 Matrix-SH Weight:151 lb FT=20% LUMBER- BRACING - TOP. CHORD 2x4 SP No.2 TOP CHORD BOT CHORD 2x4 SP No.2 "Except' BOT CHORD 1-14: 2x6 SP No.2 WEBS 2x4 SP No.3 SLIDER Left 2x4 SP No.3 3-5-2 REACTIONS. (size) 8=Mechanical, 12=0-8-0, 1=0-4-0 Max Horz 1=188(LC 9) Max Uplift 8=-360(LC 10), 12=-574(LC 10), 1=-321(LC 10) Max Grav 8=924(LC 16), 12=1104(LC 2), 1=319(LC 21) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-3= 281/237, 3-4= 167/259, 5-6=-879/667, 6-7=-1017/669, 7-8=-1499/842 BOT CHORD 12-14=-415/833, 10-12=-178/507, 9-10=-632/1251, 8-9=-632/1251 WEBS 5-1 0=-1 76/460, 5-12=-716/551, 7-10=-568/420, 3-14=-254/314 Structural wood sheathing directly applied or 4-4-4 oc purlins. Rigid ceiling directly applied or 7-1-0 oc bracing. Except: 6-0-0 oc bracing: 12-14 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterjor(2E) 0-2-0 to 4-1-10, Exterior(2R) 4-1-10 to 10-11-10, Interior(1) 10-11-10 to 12-8-6, Exterior(2R) 12-8-6 to 20-7-10, Interior(1) 20-7-10 to 23-4-6, Exterior(2E) 23-4-6 to 27-4-0 zone; cantilever left exposed ; end vertical left exposed; porch left exposed;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 360 lb uplift at joint 8, 574 lb uplift at joint 12 and 321 lb uplift at joint 1. Andrete Johanon PE No. 84943 3L7ek US11Inc. FL Ced 6634 16013 SmiagleylUdge Road, Chesterfield, NO 63017 Date: -September 14,2021 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not• a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of misses and truss systems, see ANSVTP11 Quality Criteria, DSB-89 and BCSI Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type Qty Ply 1820 B 3CAR BLK NO HS. 147880239 2866952 B04B - SPECIAL 1 1 Job Reference (optional) Builders Firstbource (Plant City, FL), Plant City, FL - 33567, 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Sep 13 15:11:20 2021 Page 1 I D:3xt?Yd6 RbYnXO16Sf6 ghjj z4cnz-s005YaeakTdAn5l li OrfNKO UuK7h_m 9jJ gCfkHye?sL -1-4-0 , 5-0-0 7-10-0 13-3-0 18-8-0 21-4-10 27-8-0. ' 1-4-0 ' S-0-0 2-10-0 5-5-0 5-5-0 2-8-10 6-3-6 Scale=1:49.3 4x6 = 2x4 11 4x4 = 3x4 = 6.00 F12 4 5 14 15 6 16 17 7 ST1.5xBSTP= 11 1u 3x4 12 4x6 = 3x8 = 6x8 = 1-0-0 -1p 0-4 5-0-0 7-8-0 7-10-0 18-8-0 27-8-0 -10-4 4-0-0 2-8-0 0- 0 10-10-0 9-0-0 0-1-12 Plate Offsets (X,Y)-- [2:0-1-2,0-1-81, [9:0-2-10,0-1-81, [12:0-3-8,0-3-01 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/dell Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.56 Vert(LL) 0.27 2-13 >345 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.72 Vert(CT) -0.52 10-12 >446 180 BCLL 0.0 * Rep Stress Incr YES WB 0.71 Horz(CT) -0.02 12 n/a n/a BCDL 10.0 Code FBC20201TP12014 Matrix-SH Weight: 137lb FT=20% LUMBER- BRACING - TOP CHORD 2x4 SP No.1 TOP CHORD Structural wood sheathing directly applied or 5-4=10 oc purlins. BOT CHORD 2x4 SP-No.1 *Except* BOT CHORD Rigid ceiling directly applied or 7-7-9 oc bracing. Except: 2-13: 2x4 SP M 31, 5-12: 2x4 SP No.2 6-0-0 oc bracing: 12-13 WEBS 2x4SPNo.3 SLIDER Left 2x6 SP No.2 2-5-15 REACTIONS. (size) 9=Mechanical, 2=0-4-0, 12=0-8-0 Max Horz 2=167(LC 9) Max Uplift 9=-353(LC 10), 2= 428(LC 10), 12=-588(LC 10) Max Grav 9=743(LC 16), 2=367(LC 19), 12=1017(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-232/382, 6-7=-840/718, 7-8=-969/763, 8-9= 1162/853 BOT CHORD 12-13=-429/827, 10-12=-327/589, 9-10=-641/965 WEBS 6-10=-88/327, 7-10=-114/291, 8-10=-305/364, 6-12=-760/601, 4-13=-203/307 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft L=40ft eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) -1-4-0 to 2-7-10, Exterior(2R) 2-7-10 to 8-11-10, Interior(1) 8-11-10 to 14-8-6, Exterior(2R) 14-8-6 to 22-7-10, Interior(1) 22-7-10 to 23-4-6, Exterior(2E) 23-4-6 to 27-4-0 zone; cantilever left exposed ; porch left exposed;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 353 lb uplift at joint 9, 428 lb uplift at joint 2 and 588 lb uplift at joint 12. AndrenJohnsoo PE No.84943 3LTek USA, lac PL Ced 6634 16073 Safagle? Ridge Road, Chesterfield, 510 63017 Date: -September 14,2021 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. _ f --Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTPI1 Quality Criteria, DSB-89 and SCSI Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type City Ply 1820 B 3CAR BLK NO HS 147880240 2866952 B05B SPECIAL Job Reference (optional) Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Sep 13 15:11:22 2021 Page 1 I D:3xt?Yd6RbYnXO16Sf6ghjjz4cnz-onKrzGfgG4tuOPvhpRt7SITpV7ptSIIOmBhmp9ye?sJ 7-10-0 14.3-0 20-8-0 27.8-0 4.10-0 6-5-0 6.5-0 7-0-0 4x4 = 6.00 12 14 5x6 = 2x4 II 15 4 16 17 5 4x8 = ST1.5x8 STP = 10 3x4 11 3x4 = 3x8 = .2x4 II 3x6 11 14-3.0 7-0-0 Scale=1:49.3 LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 ' BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr NO Code FBC2020/TP12014 CSI. TC 0.62 BC 0.67 WB 0.39 Matrix-SH DEFL. Vert(LL) Vert(CT) Horz(CT) in (loc) I/defl Ud 0.17 12-13 >538 240 0.14 12-13 >653 180 -0.07 7 n/a n/a PLATES GRIP MT20 244/190 Weight: 124lb FT=20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 4-4-1 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 7-11-13 oc bracing. Except: WEBS 2x4 SP No.3 5-9-0 oc bracing: 11-12 REACTIONS. (size) 7=Mechanical, 2=0-4-0, 11=0-8-0 Max Horz 2=126(LC 7) Max Uplift 7=-367(LC 8), 2=-564(LC 8), 11=-661(LC 8) Max Grav 7=722(LC 1), 2=407(LC 1), 11=988(LC 1) FORCES. (Ib) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-394/604, 3-4=-327/570, 4-5=-943/628, 5-6=-943/628, 6-7=-1165/587 BOT CHORD 2-13=-459/311, 12-13=-477/327, 11-12=-923/679, 4-12=-836/508, 8-9=-407/962, 7-8=-408/955 WEBS 6-8=0/286, 5-9= 372/301, 4-9=-401/983 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); porch left exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 367 lb uplift at joint 7, 564 lb uplift at joint 2 and 661 lb uplift at joint 11. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(g) 2 lb down and 60 lb up at 3-0-0, and 62 lb up at 5-0-12, and 62 lb up at 7-0-12 on top chord, and 40 lb down and 139 lb up at 3-0-0, and 15 lb down and 60 lb up at 5-0-12, and 15 lb down and 60 lb up at 7-0-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 3-6=-54, 6-7=-54, 2-12= 20, 7-11=-20 Continued on page 2 AadrelrJohasou PE \0.84943 MY& USA, Inc. FL Cert 6634 16023 Somltley Ridge Road, Chesterfield, 310 63017 Date: September 14,2021 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. '- Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTPII Quality Criteria, DSB-89 and SCSI Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type City Ply 1820 B 3CAR BLK NO HS 147880240 2866952 B05B SPECIAL 1 1 Job Reference (optional) builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Sep 13 15:11:23 2021 Page 2 I D:31d?Yd6RbYnX016Sf6ghjjz4cnz-GztEBcgS1 O?IeYUtN80M?y0_FX96BC?9?oRJLcye?sl LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 3=2(F) 13=-20(F) 14=4(F) 15=4(F) 18=-8(F) 19=-8(F) A -WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTPII Quality Criteria, DSB-69 and BCSI Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type Qty Ply 1820 B 3CAR BLK NO HS 147880241 2866952 C1 JACK 7 1 Job Reference (optional) Builders I-irstbource (Plant City, FL), Plant City, FL - 33567, 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Sep 13 15:11:25 2021 Page 1 ID:3xt?Yd6 RbYnXO16Sf6ghjjz4cnz-CM?—bHiiZ? FTtsdGUZRg4N5QYL?xfBYSS6w000ye?sG -1-4-0 0-11-4 1-4-0 0-11-4 Scale = 1:7.6 J 11.bX6 J I t'= 0-11-4 Plate Offsets (X Y)-- [2:0-1-4,Ed- e) LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Well Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.25 Vert(LL) -0.00 2 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.01 Vert(CT) -0.00 2 >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 3 n/a n/a BCDL 10.0 Code FBC202OfTP]2014 Matrix-P Weight: 5 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 0-11-4 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=78(LC 10) Max Uplift 3= 38(LC 1), 2=-213(LC 10) Max Grav 3=75(LC 10), 2=169(LC 1), 4=17(LC 3) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASIDE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Exterior(2E) zone;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 38 lb uplift at joint 3 and 213 lb uplift at joint 2. Andrew Johnson PE No. 84943 51lTek USA, Inc. EL Cert 6634 16023 Switioey Ridge Road, Chesterfield, h10 63017 Date: September 14,2021 WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. -Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall building design. Bracing indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type Qty Ply 1820 B 3CAR BLK NO HS 147880242 2866952 C1 B JACK 1 1 - - Job Reference (optional) Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Aug 16 2021 MiTek Industries, Inc. Man Sep 13 15:11:27 2021 Page 1 ID:3xt?Yd6RbYnXO16Sf6ghjjz4cnz-917kOzjz5cVB7Anec—TI9oApY8hP7521wQPW UNye?sE 0-11-4 0-11.4 2x4 = Scale = 1:6.9 ST1.5x8 STP = 0-11-4 LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.02 Vert(LL) -0.00 1 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.01 Vert(CT) -0.00 1 >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 2 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix-P Weight: 3 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 0-11-4 oc purlins. BOT CHORD 2x4 SIP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 1=0-8-0, 2=Mechanical, 3=Mechanical Max Horz 1=27(LC 10) Max Uplift 1=-7(LC 10), 2=-27(LC 10) Max Grav 1=32(LC 15), 2=28(LC 15), 3=17(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Exterior(2E) zone;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 7 lb uplift at joint 1 and 27 lb uplift at joint 2. Andrew Johnson PE \o.84943 3LTek USA, Inc. EL Ced 6634 16013 SwhiVey Ridge Road, Chesterfield, 310 63017 Date: September 14,2021 ®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 6/19/2020 BEFORE USE. ' 'Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and SCSI Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type Oty Ply 1820 B 3CAR BLK NO HS 147880243 2866952 C1 P JACK -OPEN 2 1 Job Reference (optional) Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Sep 13 15:11:29 2021 Page 1 I D:193QG W BBpX3j RI87zeOm7kz5?ad-57FVRfl DdEmvMTx1 j PVmEDG6kyMgb?Y2NkudZFye?sC 1-4-0 0-11-4 LOADING (psf) SPACING- 2-0-0 CSI. TCLL 20.0 Plate Grip DOL 1.25 TC 0.23 TCDL 7.0 Lumber DOL 1.25 BC 0.02 BCLL 0.0 Rep Stress Incr YES WB 0.00 BCDL 10.0 Code FBC2020/TPI2014 Matrix-P LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 REACTIONS. (size) 3=Mechanical, 2=0-3-8, 4=Mechanical Max Horz 2=78(LC 10) Max Uplift 3=-32(LC 1), 2=-220(LC 10), 4=-13(LC 6) Max Grav 3=67(LC 10), 2=163(LC 1), 4=18(LC 3) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. Scale =1:7.6 DEFL. in (loc) I/defl Ud PLATES GRIP VeR(LL) 0.00 2 >999 240 MT20 244/190 Vert(CT) -0.00 2 >999 180 Horz(CT) 0.00 3 n/a n/a Weight: 5 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied or 0-11-4 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft eave=5ft Cat. II; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Exterior(2E) zone; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 32 lb uplift at joint 3, 220 lb uplift at joint 2 and 13 lb uplift at joint 4. Andrelr Johnson PE N o. 84943 1LTek USA, Inc FL Cert 6634 16023 Swiagey Ridge Road, ChesterBeld,11063017 Date: September 14,2021 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. _ " Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not• a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTP11 Quality Criteria, DSB-89 and SCSI Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type City Ply 1820 B 3CAR BLK NO HS 147880244 2866952 CiV SPECIAL - 6 1 - Job Reference (optional) Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Sep 13 15:11:30 2021 Page 1 ID:193QG W BBpX3j Rl87zeOm7kz5?ad-ZJptf?IrOXum_dW DH60?nRoGaMi6KSoBcOdB5iye?sB 1-4.0 10-11.4 Scale = 1:7.6 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.23 Vert(LL) -0.00 2 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.01 Vert(CT) -0.00 2 >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 3 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix-P Weight: 5lb FT=20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD BOT CHORD 2x4 SP No.2 BOT CHORD REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=74(LC 10) Max Uplift 3=-38(LC 1), 2=-200(LC 10) Max Grav 3=63(LC 10), 2=169(LC 1), 4=17(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. Structural wood sheathing directly applied or 0-11-4 oc puffins. Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft B=45ft; L=40fh eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Exterjor(2E) zone;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 38 lb uplift at joint 3 and 200 lb uplift at joint 2. AadresrJohasoa PE \a.54943 11iTek USA, lac. FL Cer16634 16023 Ssibi ley Ridge Road, -Chesterfield, 110 63017 Date: -September 14,2021 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. -_ • Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and propedy incorporate this design into the overall building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication; storage, delivery, erection and bracing of trusses and truss systems, see ANSUTPH Quality Criteria, DSB-89 and SCSI Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type Qty Ply 1820 B 3CAR BILK NO HS 147880245 2866952 C3 JACK 7 1` - Job Reference (optional) Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Aug 16 2021 MiTek Industries, Inc. Man Sep 13 15:11:31 2021 Page 1 ID:3xt?Yd6RbYnXO16Sf6ghjjz4cnz-1 W MFsLmT9rOcbn5PrgXEJeLPem1 L3v1 Kg2Nkd8ye?sA -1-4-0 2-11.4 1-4-0 2-11-4 ST1.5x8 STP = MEM11 LOADING (psf) SPACING- 2-0-0 CS]. DEFL. in (loc) Well Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.33 Vert(LL) -0.00 2-4 >999 240 TCDL 7.0 Lumber DOL 1.25 BC 0.07 Vert(CT) -0.01 2-4 >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix-P LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=131(LC 10) Max Uplift 3=-42(LC 7), 2=-191(LC 10) Max Grav 3=55(LC 15), 2=214(LC 1), 4=51(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. Scale=1:12.7 PLATES GRIP MT20 244/190 Weight: 12 lb FT = 20 BRACING - TOP CHORD Structural wood sheathing directly applied or 2-11-4 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Exterior(2E) zone;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. - 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 42 lb uplift at joint 3 and 191 lb uplift at joint 2. AodrerrJohmoo PE No.84943 ATAUSA,I r.FLCed6634 16023 SniugleyR!dge Road, ChesterDeld, 310 63017 Date: September 14,2021 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev.5119/2020 BEFORE USE. ' 'Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTPI1 Quality Criteria, DSB-89 and BCSI Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type Oty Ply 1820 B 3CAR BLK NO HS 147880246 2866952- C3B JACK 1 1 Job Reference (optional) Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 2x4 = 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Sep 13 15:11:34 2021 Page 1 I D:3xt?Yd6RbYnXO16Sf6ghjjz4cnz-R520UMpMRmOBSFp—W y5xxHzx6z2mGGnnX?bOETye?s7 2-11-4 2-11-4 2-11-4 2-11-4 Scale: 1 "=1' LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.26 Vert(LL) -0.00 1-3 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.09 Vert(CT) -0.01 1-3 >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 2 n/a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix-P Weight: 9 lb FT = 20 LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD BOT CHORD 2x4 SP No.2 BOT CHORD REACTIONS. (size) 1=Mechanical, 2=Mechanical, 3=Mechanical Max Horz 1=79(LC 10) Max Uplift 1=-29(LC 10), 2=-84(LC 10) Max Grav 1=107(LC 15), 2=92(LC 15), 3=56(LC 3) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. Structural wood sheathing directly applied or 2-11-4 oc purlins. Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer/ Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 29 lb uplift at joint 1 and 84 lb uplift at joint 2. AadrewJohasoa PE,No.84943 ATekDSA, lac. FL Cert 6634 16023 Sotagley Ridge Road, Chesterfield,110 63017 Date: September 14,2021 -WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 10II-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not• a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek` Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTP11 Quality Criteria, DSB-89 and BCSI Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type City Ply 1820 B 3CAR BLK NO HS 147880247 2866952 C3V SPECIAL 6 1 Job Reference (optional) Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Sep 13 15:11:35 2021 Page 1 I D:193QG W BBpX3j Rl87zeOm7kz5?ad-wHcmiip_C4 W 2400B4gcAUU W 5oNOG?j 1 wlfLymvye?s6 -1-4-0 2-11-4 1.4.0 2-11-4 ST1.5xB STP = J,. r to 6 66 Scale=1:12.7 LOADING (psf) SPACING- 2-0-0 CS]. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.32 Vert(LL) -0.00 2-4 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.07 Vert(CT) -0.01 2-4 >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix-P Weight: 12 lb FT = 20 LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD BOT CHORD 2x4 SP No.2 BOT CHORD REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=128(LC 10) Max Uplift 3=-45(LC 7), 2=-187(LC 10) Max Grav 3=56(LC 15), 2=214(LC 1), 4=51(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. Structural wood sheathing directly applied or 2-11-4 oc puffins. Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific . to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Bearing at joint(s) 2 considers parallel to grain value using ANSITrPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 45 lb uplift at joint 3 and 187 lb uplift at joint 2. AndretrJohason PE No.84943 3hTek USA Inc. FL Ced 6634 16023 Safsrgley Ridge Road, Chesterfield, 310 63017 Date: September 14,2021 - A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. �D-esign valid for use only with MITek® connectors. This design is based only upon parameters shown, and is for an individual building component, not• a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek` Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTPII Quality Criteria, DSB-89 and BCSI Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type Oty Ply 1820 B 3CAR BLK NO HS 147880248 2866952 C5 JACK 7 1 Job Reference (optional) Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Sep 13 15:11:37 2021 Page 1 I D:3xt?Yd6RbYnXO16Sf6ghjjz4cnz-sgkW 7OrEkhmmdiYZB5eeZvbOfA2wTd W DDzg2roye?s4 -1-4.0 4-11-4 1.4.0 4-11-4 ST1.5x8 STP = Scale = 1:17.6 4-11.4 4-11.4 Plate Offsets (X,Y)-- (2:0-1-4,0-0-21 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Vdefl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.56 Vert(LL) -0.03 2-4 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.25 Vert(CT) -0.05 2-4 >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix-P Weight: 18lb FT=20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood.sheathing directly applied or 4-11-4 oc puffins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=184(LC 10) Max Uplift 3=-113(LC 10), 2=-192(LC 10) Max Grav 3=132(LC 15), 2=277(LC 15), 4=91(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MW FRS (directional) and C-C Exterior(2E) zone;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 113 lb uplift at joint 3 and 192 lb uplift at joint 2. Andrew Johnson PE No. 84943 1LTek USA, Inc FL Cerf 6634 16013 Sidnglep Ridge Road; Chesterfield, bf0 63017 Date: - -September 14,2021- A WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. - D'esign valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek Is always -required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTPII Quality Criteria, DSB-89 and BCSI Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf; MD 20601 Chesterfield, MO 63017 Job Truss Truss Type Oty Ply 1820 B 3CAR BLK NO HS 147880249 2866952 C5B JACK 1 1 Job Reference (optional) owiunra ruarouurue triani Uuy, rLh rlalm Uny, rL - J0301, 0.40U S HUg I b ZUZI mi I eK InDUsines, Inc. mon bep is 1b:11:3t3 zUZI rage 1 I D:3xt?Yd6RbYnXO16Sf6ghjjz4cnz-KsHvKkssV?udxs7micAu678VBaNdC4mM RdZcNEye?s3 4-11-4 4-11-4 Scale = 1:16.9 2x4 = 3- 4-11-4 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/dell L/d PLATES _GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.83 Vert(LL) -0.03 1-3 >999 240 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.29 Vert(CT) -0.06 1-3 >898 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 2 n/a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix-P Weight: 16 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 4-7-8 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 1=Mechanical, 2=Mechanical, 3=Mechanical Max Horz 1=133(LC 10) Max Uplift 1=51(LC 10), 2=-143(LC-10) Max Gram 1=183(LC 15), 2=157(LC 15), 3=96(LC 3) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASIDE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. il; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer/ Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 51 lb uplift at joint 1 and 143 lb uplift at joint 2. Andrew Johnson PE No. 84943 \UTek USA, Inc. FL Cert 6634 16033 Swinliley Ridge Road, Chesterfield, 31063017 Date: September-14,2021 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. ' Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIrTPl1 Quality Criteria, DSB-69 and BCSI Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type Qty Ply 1820 B 3CAR BILK NO HS 147880250 2866952 C5V SPECIAL 6 1 Job Reference (optional) muuuers nrscbuurce trianr ugly, r-L./, 0 Plate Offsets (X,Y)-- [2:0-4-7,Edge rianr Lary, rL - aaaor, a.43u s Hug 1 e zucl Ivu I eK Inousmes, Inc. ivion bep 1;j 1 ts:n:4u tun rage 1 ID:193QGW BBpX3jRI87zeOm7kz5?ad-GFPRQt61 c8LAAHBtDCMBYDvcO3bg—Gfvx2jS7ye?s1 -1-4.0 4-11-4 1-4-0 4-11-4 Scale = 1:17.6 ST1.5x6 STP = r- m o d LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/dell Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.58 Verl(LL) -0.03 2-4 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.25 Verl(CT) -0.05 2-4 >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix-P Weight: 18lb FT=20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 4-11-4 oc purlins. BOT CHORD 2x4 SIP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=182(LC 10) Max Uplift 3=-116(LC 10), 2=-189(LC 10) Max Grav 3=133(LC 15), 2=276(LC 15), 4=91(LC 3) FORCES. (Ib) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 116 lb uplift at joint 3 and 189 lb uplift at joint 2. AndrewJobson PE \o.84943 11iTekDSA, Inc FL Cert 6634 16023StrineeyRidgeRoad,Chesterfield M063017 Date: September 14,2021 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. ' - Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTPl1 Quality Criteria, DSB-89 and BCSI Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type Qty Ply 1820 B 3CAR BLK NO HS, 147880251 2866952 D02B HIP 1 1 Job Reference (optional) Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Sep 13 15:11:42 2021 Page 1 ID:3xt?Yd6RbYnXO16Sf6ghjjz4cnz-CdXPA5vNZD03QTRX_eEgGzlA1 BcM8pcyMFXpW?ye?s? 7-0.0 13-0-0 19-11-4 21-3.4 7-0-0 6-0.0 6-11-4 1-4-0 4x8 = 10 4x6 = Scale=1:34.8 1 - - 5 Iol 11 7 12 s s 4x4 = 8 2x4 11 4x4 6 3x4 — s ST1.5x8 STP = 4x4 = 7-0-0 13.0.0 19-11-4 _ 7-0-0 6-0-0 6-11-4 Plate Offsets (X,Y)-- [1:0-1-4,Edge], [2:0-5-4,0-2-01, [3:0-3-8,0-2-01 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.84 Vert(LL) 0.13 1-8 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.81 Vert(CT) -0.18 1-8 >999 180 BCLL 0.0 Rep Stress Incr NO WB 0.27 Horz(CT) 0.07 4 n/a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix-SH Weight: 83 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.1 TOP CHORD Structural wood sheathing directly applied or 1-7-8 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 5-9-10 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (size) 1=Mechanical, 4=0-8-0 Max Horz 1— 162(LC 6) Max Uplift 1= 668(LC 8), 4=-824(LC 8) Max Grav 1=1322(LC 1), 4=1424(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-2= 2449/1229, 2-3=-2097/1184, 3-4=-2436/1250 BOT CHORD 1-8=-930/2093, 6-8=-933/2116, 4-6=-942/2074 WEBS 2-8=-85/686, 2-6=-288/44, 3-6— 61/699 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) . This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Refer to girder(s) for truss to truss connections. 8) Provide mechanical connection (by others) -of truss to bearing plate capable of withstanding 668 lb uplift at joint 1 and 824 lb uplift at joint 4. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 116 lb down and 87 lb up at 7-0-0, 86 lb down and 162 lb up tt 94-12, and 86 lb down and 162 lb -up at 10-11-4, and 116 lb down and 290 Ib up at 13-0-0 on - top chord, and 374 lb down and 163 lb up at 7-0-0, 65 lb down at 9-0-12, and 65 lb down at 10-11-4, and 374 lb down and 163 lb up at 12-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-2=-54, 2-3=-54, 3-5=-54, 1-4=-20 Concentrated Loads (lb) Vert: 2=-1 16(B) 3=-116(0) 8=-374(B) 6=-374(B) 9=-86(B) 10=-86(B) 11=-40(B) 12=-40(B) Andms Johnson PE No. 84943 3TTekU,SA, Iar. FL Ced 6634 16023 Swinoey'I idge Road, Chesterfield, 310 63017 Date: September 14,2021 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 10II-7473 rev. 5/19/2020 BEFORE USE. ' .Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see AN617rP11 Quality Criteria, DSB-89 and BCSI Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type Oty Ply 1820 B 3CAR BLK NO HS 147880252 2866952 E3 JACK 3 1 - Job Reference (optional) Builders FirstSource (Plant City, FL), Plant. City, FL - 33567, 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Sep 13 15:11:45 2021 Page 1 ID:3xt7Yd6RbYnX016Sf6ghjjz4cnz-dCDYo7xFs8ndHx96fmoXubwp1 PnFLEV02DmT6Kye7ry -1-4-0 3-0.0 1-4-0 3-0-0 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d TOLL 20.0 Plate Grip DOL 1.25 TO 0.28 Vert(LL) 0.02 2-4 >999 240 TCDL 7.0 Lumber DOL 1.25 BC 0.22 Vert(CT) 0.02 2-4 >999 180 BOLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix-P LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 REACTIONS. (size) 3=Mechanical, 2=0-4-0, 4=Mechanical Max Horz 2=132(LC 10) Max Uplift 3=-49(LC 10), 2=-226(LC 10), 4=-40(LC 6) Max Gram 3=69(LC 15), 2=205(LC 1), 4=55(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. Scale=1:12.8 PLATES GRIP MT20 244/190 Weight: 12 lb FT = 20 BRACING - TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASIDE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer/ Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 2C.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 49 lb uplift at joint 3, 226 lb uplift at joint 2 and 40 lb uplift at joint 4. AndrewJohnsoo PE Nti.84943 1LTek USA, lac FL Ced 6634 16013 Samgley Ridge Road, Chesterfield,110 63017 Date: September 14,2021 - ® WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. - -Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek` Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPI1 quality Criteria, DSB-89 and BCSI Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type Oty Ply 1820 B 3CAR BLK NO HS 147880253 2866952 E7 JACK B 1 Job Reference (optional) Dununrs rubtauurce iriant t.ry, ry, rlarr t,lry, rL - JJDor, Jx4 - ST1.5xB STP = 0.4JU s Mug 113 ZUe r NII I eK Inausines, Inc. ivion oep 1J io:l 1:4/ zuei rage 7 ID:3xt?Yd6RbYnXO16Sf6ghjjz4cnz-ZbKIDpzVNmi LW EJUnBq?zO?5kCNJpB?hWXFaADye?rw 7-0.0 Scale=1:23.5 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/dell Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.52 Vert(LL) -0.11 2-4 >695 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.57 Vert(CT) -0.23 2-4 >347 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2020/TPI2014 Matrix-P Weight: 24 lb FT = 20 LUMBER - TOP CHORD 2x4 SP M 31 BOT CHORD 2x4 SP No.2 REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=240(LC 10) Max Uplift 3=-181(LC 10), 2=-207(LC 10) Max Gram 3=204(LC 15), 2=351(LC 15), 4=132(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40fh eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer/ Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed fora 10.0 psf bottom chord live load nonconcurrent with any other jive loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 181 lb uplift at joint 3 and 207 lb uplift at joint 2. Andrew Jahason PE No. 84943 1111ekUSA, Inc. FL Cerf 6634 16023 Snmgley Ridge goad, Chesterfield, MO 63017 Date: September 14,2021 A WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. -Design valid for use only with MiTekO connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Duality Criteria, DSB-89 and BCSI Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Jab Truss Truss Type Qty Ply 1820 B 3CAR BILK NO HS 147880254 2866952 E7V SPECIAL 10- 1 Job Reference (optional) Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Sep 13 15:11:49 2021 Page 1 ID:193QGWBBpX3jRl87zeOm7kz5?ad-VzS3e\_mvNH31YTtucsT2R5R4031H2V_zrkhF5ye?ru -1-4-0 7-0-0 1.4.0 7-0-0 ST1.5x8 STP = LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Well Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.53 Vert(LL) -0.12 2-4 >674 240 TCDL 7.0 Lumber DOL 1.25 BC 0.57 Vert(CT) 0.24 2-4 >337 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix-P LUMBER- BRACING - TOP CHORD 2x4 SP M 31 TOP CHORD BOT CHORD 2x4 SP No.2 BOT CHORD REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=237(LC 10) Max Uplift 3=-184(LC 10), 2= 204(LC 10) Max Grav 3=205(LC 15), 2=350(LC 15), 4=132(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. Scale=1:23.2 PLATES GRIP MT20 244/190 Weight: 25 lb FT = 20% Structural wood sheathing directly applied or 6-0-0 oc purlins. Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer/ Project engineer responsible forverifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed fora 10.0 psf bottom chord live load nonconcurrent with any other live loads. - 4) . This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should Verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 184 lb uplift at joint 3 and 204 lb uplift at joint 2. Andress Johnson PEA. 84943 3fQelt USA, Inc. Fill, Ced6634 16023 Swinlitty Ridge Road, Cbesterfield, A10 63017 Dale: September 14,2021 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 10II-7473 rev. 5/19/2020 BEFORE USE. - Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type City Ply 1820 B 3CAR BLK NO HS 147880255 2866952 E7VP SPECIAL 7 1 - Job Reference (optional) Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Sep 13 15:11:50 2021 Page 1 - ID:3xt?Yd6RbYnX016Sf6ghj1z4cnzw AORrq?OghPwNi23SJNibfdc?QRHOVk7CVTEnXye?rt -1-4-0 7-0-0 1-4-0 7-0-0 Scale=1:23.3 3x4 Plate Offsets_(X,Y)-- [2:0-7-15,0-0-11], [2:0-0-12,Edge] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.52 Vert(LL) 0.11 2-4 >735 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.42 Vert(CT) 0.09 2-4 >856 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix-P Weight:31 lb FT=20% LUMBER- BRACING - TOP CHORD 2x4 SP M 31 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x6 SP-No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=303(LC 10) Max Uplift 3= 181(LC 10), 2=-327(LC 10), 4=-102(LC 6) Max Grav 3=204(LC 15), 2=346(LC 1), 4=132(LC 3) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 181 lb uplift at joint 3, 327 lb uplift at joint 2 and 102 lb uplift at joint 4. Andrew Johnson PE No.84943 31tTek USA, Inc. R Cent 6634 16023 S1lmgley Ridge Road, Chesterfield, MO63017 Date: September 14,2021 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mil-7473 rev. 5/19/2020 BEFORE USE. -" Dbsign valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek` is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTP11 Quality Criteria, DSB-89 and BCSI Building Component 16023'Swingiey Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type City Ply 1820 B 3CAR BLK NO HS 147880256 2866952 H3 JACK 1 1 - Job Reference (optional) Builders FirstSource (Plant City, FL), Plant City, FL - 33567, -1-10-10 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Sep 13 15:11:53 2021 Page 1 I D:3xt?Yd6RbYnXO16Sf6ghjjz4cnz-OlhZUsi GzcnVE9me7SxPDH FAFd W VDsUauTivOsye?rq 4-2-3 4-2-3 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d TCLL 20.0 Plate Grip DOL 1.25 TC 0.32 Vert(LL) 0.03 2-4 >999 240 TCDL 7.0 Lumber DOL 1.25 BC 0.14 Vert(CT) -0.02 2-4 >999 180 BCLL 0.0 Rep Stress Incr NO WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix-P LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD BOT CHORD 2x4 SP No.2 BOT CHORD REACTIONS. (size) 3=Mechanical, 2=0-4-8, 4=Mechanical Max Horz 2=131(LC 8) Max Uplift 3= 31(LC 5), 2=-258(LC 8), 4=-60(LC 4) Max Grav 3=62(LC 1), 2=241(LC 1), 4=64(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. Scale=1:12.6 PLATES GRIP MT20 244/190 Weight: 16 lb FT = 20 Structural wood sheathing directly applied or 4-2-3 oc purlins. Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); porch left exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer/ Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 31 lb uplift at joint 3, 258 lb uplift at joint 2 and 60 lb uplift at joint 4. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 56 lb down and 62 lb up at 1-5-12, and 56 lb down and 62 lb up at 1-5-12 on top chord, and 22 lb up at 1-5-12, and 22 lb up at 1-5-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 2-4=-20 Concentrated Loads (lb) Vert: 5=46(F=23, B=23) 6=22(F=11, B=11) Andrew Johnson PE \o.84943 1LTekUSA, Inc. FL Ced 6634 16013 Spin_ gley Ridge Road, -Chesterfield, 110 63017 Dale: September 14,2021 ® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 6/19/2020 BEFORE USE. " Design valid for use only with MiTek@ connectors. This design is based only upon parameters shown, and is for an Individual building component, not• a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIfrPll Quality Criteria, DSB-89 and BCSI Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type City Ply 1820 B 3CAR BLK NO HS 147880257 2866952 H7 MONO TRUSS 4 1 Job Reference (optional) Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Sep 13 15:11:54 2021 Page 1 I D:3xt?Yd6RbYnXO16Sf6ghjjz4cnz-sxFyhC2ukvvMsJLgh9SelVoGkl jOyE7j77RSwJye?rp 1-10-10 4-6-7 9-10-1 1-10-10 4-6-7 5-3-10 R ox% - ST1.5x8 STP = Scale = 1:23.0 4-6-7 5-3-10 Plate Offsets (X,Y)-- [2:0-2-4,0-0-0] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/dell Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.66 Vert(LL) -0.07 6-7 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 _BC 0.73 Vert(CT) -0.15 6-7 >778 180 BCLL 0.0 Rep Stress Incr NO WB 0.36 Horz(CT) 0.01 5 n/a n/a BCDL 10.0 Code FBC2020ITP12014 Matrix-SH Weight: 43 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 9-10-12 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (size) 4=Mechanical, 2=0-8-0, 5=Mechanical Max Horz 2=239(LC 8) Max Uplift 4=-167(LC 8), 2= 247(LC 8), 5=-70(LC 5) Max Grav 4=160(LC 1), 2=452(LC 1), 5=292(LC 3) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-697/224 BOT CHORD 2-7=-313/629, 6-7=-313/629 WEBS 3-7=0/323, 3-6=-664/330 NOTES- 1) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft L=40ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 167 lb uplift at joint 4, 247 lb uplift at joint 2 and 70 lb uplift at joint 5. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 56 lb down and 62 lb up at 1-5-12, 56 lb down and 62 lb up at 1-5-12, 5 lb down and 68 lb up at 4-3-11, 5 lb down and 68 lb up at 4-3-11, and 50 lb down and 138 lb up at 7-1-10, and 50lb down and 138 lb up at 7-1-10 on top chord, and 22 lb up at 1-5-12, 22 Ito up at 1-5-12, 11 lb down and 7 Ib up at 4-3-11, 11 Ib down and 7 Ib up at 4-3-11, and 51 Ib down at 7-1-10, arid 51 Ib down at 7-1-10 on bottom chord. The - design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard . 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-4=-54, 2-5=-20 AndrewJohmmnPE\a.84943 MTekUSA, Iac. FL Ced 6634 16023 Shingley Ridge Road, Chesterfield, HO 63017 Date: Continued on page 2 September 14,2021 A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 5/19/2020 BEFORE USE. -Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall`' building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTPl1 Quality Criteria, DSB-89 and BCSI Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type City Ply 1820 B 3CAR BLK NO HS 147880257 2866952 H7 MONO TRUSS 4 1 Job Reference (optional) Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Sep 13 15:11:54 2021 Page 2 ID:3xt?Yd6RbYnX016Sf6ghjjz4cnz-sxFyhC2ukvvMsJLgh9Sel VoGk1 jOyE7j77RSwJye?rp LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 3=36(F=18, B=18) 7=-11(F=-5, B=-5) 8=46(F=23, B=23) 9=-99(F=-50, B=-50) 10=22(F=11, B=11) 11=-51(F= 25, B=-25) A WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. ' -•Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTPI1 Quality Criteria, DSB-89 and SCSI Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type Qty Ply 1820 B 3CAR BLK NO HS 147880258 2866952- H7V SPECIAL- 3 - 1 - Job Reference (optional) Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Sep 13 15:11:55 2021 Page 1 I D:193QG W BBpX3j R187zeOm7kz5?ad-K7pKuY3XVD 1 DUTwi FsztliLTsR5chhosMnB?Tlye?ro -1-10-10 5.4-1 9-10-1 1-10-10 5.4-1 4-6-0 2 3x4 ST1.5x8 STP = Scale=1:22.9 o a 6 5.4.1 9-10-1 5-4.1 4-6-0 Plate Offsets (X,Y)-- [2:0-1-3,Edge] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.57 Vert(LL) 0.07 6-7 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.61 Vert(CT) -0.11 6-7 >999 180 BCLL 0.0 Rep Stress Incr NO WB 0.33 Horz(CT) -0.01 5 n/a n/a BCDL 10.0 Code FBC2020ITP12014 Matrix-SH Weight:41 lb FT=20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 5-9-14 oc puffins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 6-11-4 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (size) 4=Mechanical, 2=0-8-0, 5=Mechanical Max Horz 2=236(LC 8) Max Uplift 4=-166(LC 8), 2=-272(LC 8), 5=-161(LC 5) Max Grav 4=136(LC 1), 2=448(LC 1), 5=295(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -Ali forces 250 (lb) or less except when shown. TOP CHORD 2-3=-992/637 BOT CHORD 2-7=-703/911, 6-7=-710/907 WEBS 3-7=0/315, 3-6=-894/696 NOTES- 1) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 166 lb uplift at joint 4, 272 lb uplift at joint 2 and 161 lb uplift at joint 5. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 67 lb down and 52 lb up at 1-5-12, 67 lb down and 52 lb -up at 1-5-12, 80 Ib up at-4-3-1 1, 80 lb up at 4-3-11, and 50 lb down and 174 lb up at 7-1-10, and 50 lb down and 174 lb up at 7-1-10 on top chord, and 23 lb up at 1-5-12, 23 lb up at 1-5-12, 11 lb down and 7 lb up at 4-3-11, 11 lb down and 7 lb up at 4-3-11, and 51 lb down at 7-1-10, and 51 lb down at 7-1-10 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Andrew Johnson PENo. 84943 Uniform Loads (plf) 1hTekUSA, Inc. FLCed6634 Vert: 1-4=-54, 2-5=-20 16023SwiogleyRidge Road, Chesterfield, 11063017 Dale: Continued on page 2 - -September 14,2021 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. -Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, note a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Duality Criteria, DSB-89 and BCSI Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type Qty Ply 1820 B 3CAR BLK NO HS 147880258 2866952 H7V SPECIAL 3 1 - Job Reference (optional) Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Sep 13 15:11:55 2021 Page 2 ID:193QGW BBpX3j R187zeOm7kz5?ad-K7pKuY3XVD1 DUTwl FsztliLTsR5chhosMnB?Tlye?ro LOAD CASE(S) Standard Concentrated Loads (Ib) Vert: 8=49(F=24, B=24) 9=36(F=18, B=18) 10=-99(F=-50, B=-50) 11=23(F=11, B=11) 12=-11(F=-5, B=-5) 13=-51(Fm-25, B=-25) ® WARNING -Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. - Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not• a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MITek• Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the - fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTP11 Quality Criteria, DSB-89 and BCSI Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type Qty Ply 1820 B 3CAR BLK NO HIS 147880259 2866952 K20 Hip Girder 1 1 Job Reference (optional) Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Sep 13 15:11:56 2021 Page 1 ID:J9w?pBQ34m W MQGbmZiytDpyLuUA-oKNi6u49GX935dVDpaU6gwtXYrPtQ8hOaRwZ?Bye?m 110 7-0-0 13-0-0 20-0-0 , 21-4-0 , 1-4.0 7.0-0 6-0-0 7.0-0 1-4-0 4xB NAILED 3 NAILED NAILED NAILED 4x6 = Scale = 1:36.9 ST1.5x8 STP = 3x6 11 4x4 = 6x8 = ST1.5x8 STP = 4x4 = Special Special LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.96 Vert(LL) 0.20 7-9 >999 240 TCDL 7.0 Lumber DOL 1.25 BC 0.73 Vert(CT) -0.24 7-9 >948 180 BCLL 0.0 Rep Stress Incr NO WB 0.35 Horz(CT) 0.06 5 n/a n/a BCDL 10.0 Code FBC2020/TP12014 Matrix-SH LUMBER - TOP CHORD 2x4 SP M 31 *Except` 3-4: 2x4 SP No.2 BOT CHORD 2x4 SP No.1 WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 5=0-8-0 Max Horz 2=171(LC 7) Max Uplift 2=-954(LC 8), 5=-954(LC 8) Max Grav 2=1827(LC 13), 5=1827(LC 14) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3= 3284/1555, 3-4=-2912/1465, 4-5=-3285/1555 BOT CHORD 2-9=-1207/2929, 7-9=-1224/2977, 5-7=-1207/2838 WEBS 3-9=-404/1159, 4-7=-418/1191 4x4 = PLATES GRIP MT20 244/190 Weight: 86 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 5-6-0 oc bracing. "Special" indicates special hanger(s) or other connection device(s) required at location(s)shown. The design/selection of such special connection device(s) is the responsibility of others. This applies to all applicable truss designs in this job. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASIDE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer/ Project engineer responsible forverifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 954 lb uplift at joint 2 and 954 lb uplift at joint 5. 8) Girder carries hip end with 7-0-0 end setback. 9) "NAILED" indicates 3-1Od (0.148"x3") or 3-.12d (0.148"x3.25") toe -nails per NDS guidlines. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 733 lb down and 321 lb up at 13-0-0, and 733 lb down and 321 lb up at 7-0-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 3-4=-70(F=-16), 4-6=-54, 2-9=-20, 7-9=-89(F=-69), 5-7=-20 Continued on page 2 AudreirJohason PE No.84943 hhTekUSA, fac. FL Cert6634 16023 Soinglep Ridge Road, Chesterfield, 310 63017 Date: September 14,2021 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. J - -"Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not• a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design into the overall building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/rPl1 Quality Criteria, DSB-89 and SCSI Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type Qty Ply 1820 B 3CAR BLK NO HS 147880259 2866952 K20 Hip Girder 1 1 Job Reference (optional) Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Sep 13 15:11:56 2021 Page 2 I D:J9w?pBQ34mW MQGbmZiytDpyLuUA-oKNi6u49GX935dVDpaU6gwtXYrPtQBhOaRwZ?Bye?m LOAD CASE(S) Standard Concentrated Loads (lb) Vert: 9=-475(F) 7=-475(F) A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. v ' - Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not, a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek` is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the - fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type City Ply 1820 B 3CAR BLK NO HS 147880260 2866952 K21 Hip 1 1 Job Reference (optional) Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Sep 13 15:11:57 2021 I D:J9w?pBQ34mW MQGbmZiytDpyLuUA-G W x4JE4n1 gHwjn4PMH?LN7QpAEmk9fW 9p4g6X 6.3-6 9-0-0 11-0-0 13.8-10 20-0-0 21-4-C 6-3-6 2-8-10 2-0-0 2-8-10 6-3-6 1.4.0 A- ST1.5x8 STP = LOADING (psf) SPACING- 2-0-0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 7.0 Lumber DOL 1.25 BCLL 0.0 ' Rep Stress Incr YES BCDL 10.0 Code FBC2020/TPI2014 4x4 = 4x4 = 3x4 = 4xo 3x4 = CSI. DEFL. in (loc) I/defl Ud TC 0.52 Vert(LL) -0.15 1-10 >999 240 BC 0.69 Vert(CT) -0.32 1-10 >730 180 WB 0.13 Horz(CT) 0.03 6 n/a n/a Matrix-SH LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD BOT CHORD 2x4 SP No.2 BOT CHORD WEBS 2x4 SP No.3 REACTIONS. (size) 1=0-8-0, 6=0-8-0 Max Horz 1=-204(LC 8) Max Uplift 1= 334(LC 10), 6=-469(LC 10) Max Grav 1=711(LC 1), 6=809(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-2— 1126/870, 2-3=-916/767, 3-4=-774/710, 4-5=-912/756, 5-6=-1131/842 BOT CHORD 1-10=-578/1003, 8-10= 305/774, 6-8=-539/939 WEBS 2-10=-353/409, 3-10=-265/338, 4-8=-202/318, 5-8=-336/350 Scale=1:36.7 44 = PLATES GRIP MT20 244/190 Weight: 90 lb FT = 20 Structural wood sheathing directly applied or 4-8-7 oc purlins. Rigid ceiling directly applied or 7-3-15 oc bracing. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) 0-4-0 to 4-3-10, Exterior(2R) 4-3-10 to 16-7-5, Interior(1) 16-7-5 to 17-4-6, Exterior(2E) 17-4-6 to 21-4-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 4) Provide adequate drainage to prevent water ponding. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 334 lb uplift at joint 1 and 469 lb uplift at joint 6. AndrewJohnsoa PE No.84943 1DTekUSA, Inc. FL Cert 6634 16023 StiinBley Ridge Road, Chesterfield,110 63017 Date: September 14,2021 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. 'Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not• a truss system. Before use, the building designer must verify the applicability of design parameters and propedy incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTP11 Quality Criteria, DSB-89 and SCSI Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type Qty Ply 1820 B 3CAR BLK NO HS 147880261 2866952 K23 Hip Girder 1 2 Job Reference (optional) timaers rlrsl5ource irlant tiny, rL), rtant lay, rL - 33b6/, 8.43U s Aug I b 2U21 MI I eK Industries, Inc. Mon Sep 13 15:11:59 2021 Page 1 ID:J9w?pBQ34m W MQGbmZiytDpyLuUA-Dv3rkv61 ZSXey4EoUi2pSYVBd2 WtdPUSH09DcW ye?rk 10-3-0 i -1-4-0 6-3-0 9-9-0 0-4 10i 14-9-0 20-0-0 21-4-0 1-4-0 5-3-0 4-6-0 OLL3770 4-6-0 5-3-0 1-4-0 0-3-0 Scale = 1:39.2 4x4 11 3x8 i Offsets Jxts rxb = HTU26 HTU26 3X6 10-3-0 5-3-0 9-9-0 10-q-0 14-9-0 20-0-0 5-3-0 4-6-0 0r3-0 4-6-0 5-3-0 - 0-3-0 LOADING (psf) SPACING- 2-0-0 CSI. TCLL 20.0 Plate Grip DOL 1.25 TC 0.40 TCDL 7.0 Lumber DOL 1.25 BC 0.39 BCLL 0.0 Rep Stress Incr NO WB 0.74 BCDL 10.0 Code FBC2020/TP12014 Matrix-SH LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x6 SP M 26 WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 6=0-8-0 Max Horz 2=232(LC 7) Max Uplift 2=-1651(LC 8), 6=-2059(LC 8) Max Grav 2=3159(LC 1), 6=4262(LC 30) DEFL. in (loc) I/dell Ud Vert(LL) 0.14 9-11 >999 240 Vert(CT) -0.19 9-11 >999 180 Horz(CT) 0.04 6 n/a n/a 3x8 PLATES GRIP MT20 244/190 Weight: 226 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied or 4-7-3 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-6405/3152, 3-4=-4664/2360, 4-5=-4668/2362, 5-6=-6786/3192 BOT CHORD 2-11=-2651/5610, 9-11=-2651/5610, 8-9=-2694/5956, 6-8= 2694/5956 WEBS 3-11= 655/1460, 3-9=-1710/922, 5-9=-2447/1054, 5-8= 743/2028, 4-9=-1899/3861 NOTES- 1) 2-ply truss to be connected together with 10d (0.131 "x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. - Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-7-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (8) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-16; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; B=45ft; L=40ft; eave=5ft; Cat. 11; Exp C; Encl., GCpj=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 5) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to the use of this truss component. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1651 lb uplift at joint 2 and 2059 lb uplift at joint 6. 9) Girder carries tie-in span(s): 20-0-0 from 6-4-12 to 20-0-0 10) Use Simpson Strong -Tie HTU26 (20-1 Od Girder, 14-1 Odx1 1/2 Truss, Single Ply Girder) or equivalent at 6-4-12 from the left end to connect truss(es) to front face of bottom chord, skewed 0.0 deg.to the right, sloping 0.0 deg. down. 11) Use Simpson Strong -Tie HTU26 (20-1 Od Girder, 11-1 Odx1 1/2 Truss, Single Ply Girder) or equivalent spaced at 2-0-0 oc max. starting at 8-4-12 from the left end to 18-0-0 to connect truss(es) to front face of bottom chord. 12) Fill all nail holes where hanger is in contact with lumber. 13) Special hanger(s) or other connection device(s) shall be provided at 20-0-0 from the left end sufficient to connect truss(es) to front face of bottom chord. The design/selection of such special connection device(s) is the responsibility of others. t26dsA&QA&l,(fabESMndard AndrewJobmon PE \o.84943 JLTek USA, Inc FL Cert 6634 16013 Snfngley Ridge Road, Chesterfield, MO 63017 Date: September 14,2021 A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. • -Design valid for use only with MITekO connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design into the overall building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS[rrPl1 Quality Criteria, DSB-89 and SCSI Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Job Truss Truss Type Qty Ply 1820 B 3CAR BLK NO HS 147880261 2866952 - K23 Hip Girder 1 2 L Jab Reference (optional) Builders FirstSource (Plant City, FL), Plant City, FL - 33567, 8.430 s Aug 16 2021 MiTek Industries, Inc. Mon Sep 13 15:11:59 2021 Page 2 I D:J9w?pBQ34mW MQGbmZiytDpyLuUA-Dv3rkv61 ZSXey4EoUi2pSYVBd2 W tdPUSH09DcW ye?rk LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-4=-54, 4-7=-54, 2-12= 20, 6-12=-341(F=-321) Concentrated Loads (lb) Vert: 12=-1302(F) A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev.5/19/2020 BEFORE USE. " Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not• a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall building design. Bracing indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek Is always required for stabilityandto prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and SCSI Building Component 16023 Swingley Ridge Rd Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Chesterfield, MO 63017 Symbols PLATE LOCATION AND ORIENTATION y 3/4' Center plate on joint unless x, y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and fully embed teeth. -. For 4 x 2 orientation, locate plates 0- 1/10 from outside edge of truss. This symbol indicates the required direction of slots in connector plates. Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the plate 4 x 4 width measured perpendicular to slots. Second dimension is the length parallel to slots. LATERAL.BRACING LOCATION Indicated by symbol shown and/or by text in the bracing section of the output. Use T or I bracing if indicated. BEARING Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Min size shown is for crushing only. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction DSB-89: Design Standard for Bracing. BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. 0 cc O 2 U 0- 0 1-- Numbering System 6-4-8 dimensions shown in it -in -sixteenths (Drawings not to scale) 2 3 TOP CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. PRODUCT CODE APPROVALS ]CC -ES Reports: ESR-1311, ESR-1352, ESR1988 ER-3907, ESR-2362, ESR-1397, ESR-3282 �. General Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI. 2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered. 3. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 4. Provide copies of this,truss design to the building designer, erection supervisor, property owner and all other interested parties. 5.' Cut members to bear tightly against each other. 6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1. 7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1. 8. Unless otherwise noted, moisture content of lumber shall not exceed 19%;at time of fabrication. 9. Unless expressly noted, this design is not applicable for use with fire retardant; preservative treated, or green lumber 10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements. 12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. Trusses are designed for wind loads in the plane of the 13. Top chords must be sheathed or purlins provided at truss unless otherwise shown. spacing indicated on design. 14. Bottom chords require lateral bracing at 10 ft. spacing, Lumber design values are in accordance with ANSI/TPI' 1 or less, if no ceiling islinstalled, unless otherwise noted. section 6.3 These truss designs rely on lumber values established by others. 15. Connections not shown are the responsibility of others. 16. Do not cut or alter truss member or plate without prior approval of an engineer. © 2012 MiTek® All Rights Reserved 17. Install and load vertically unless indicated otherwise. MiTek® MiTek Engineering Reference Sheet: Mll-7473 rev. 5/19/2020 18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use. 19.. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient. 20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria. 21.The design does not take into account any dynamic or other loads other than those expressly stated.