HomeMy WebLinkAboutProduct Approval-Roof Deck6
o s o
a ► G 0 „ o , 6 _
aCIS Home. i Log In I User Registration, HotTopits I Submitsurchate I Stats & Facts I Publications I Contact Us I Bps Site Map Links Search
bp
a
�1 Product Approval
+. USER: Public User
d
ri�:Uistsrs
Product Approval Menu > Product or All ligation Search > Application list > ApplleationZetall
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
f-S�gory
Corhpllance. Method
KLU7_ V t
FL27402-R2
Revision MAR 0 4 2022
2020
Approved ST. Lucie County, Permitting
Carports Anywhere
10858 S.E. County Road 221
Starke, FL
(352)468-1116
bodom@carportsanywhere.com
Brandle Odom
bodom@carportsanywhere.com
Structural -Components
Roof Deck
UPI
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
i Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the )ohnathan Green
Evaluation Report
Florida License
PE-88223
Quality Assurance Entity
PRI Construction Materials Technologies,. LLC
Quality Assurance. Contract .ExpirationDate
06/23/202A
Validated By
Brian ]aks, P.E.
i2 Validation Checklist - Hardcopy Received
Certificate of .Independence FL27402 R2 'COI- Letter of Certification-CaroortsAnywhere sealed.pdf
Referenced Standard and Year (of Standard) Standard Year
ASTM E 1592 2005
FM 4471 1992
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted
08/04/2020
Date Validated
08/10/2020
Date Pending F13C Approval
08/19/2020
Date Approved
10/13/2020
FL #
Model, Number or Name
Description
'27402.1
Hampton Rib.Roof Panel
Hampton Rib Roof Panel over Open. Framing
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
FL27402 R2 II Hampton Rib Roof Panel DRAFT sealed.Ddf
Verified By: 7ohnathan E Green, P.E. 88223
Approved for use outside HVHZ: Yes
Impact. Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +54.7 psf/-57,3 psf
Evaluation Reports
Other: See evaluation report for various design pressures
Install per Manufacturer's details. Not for use in HVHZ Zones.
FL27402 'R2 AE Hampton Rib Roof Panel DRAFT sealed.pd
Created by Independent Third Party: Yes
Contact Us 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824
The Stateof Florida Is an AA/EEo.employer: Co�yrlgs 2007=2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, emall-addresses are public, records. -If you do not want your e=mall address released In response to a public -records request, do not send eled mnle
mall to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850:487.1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012; licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emalis
provided may be,used far official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address.which can .be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please dick bgre .
Product Approval Accepts:
\ M-9-9, IWEI ® ME
M
-0 • w
securitwar, rires
_I Force Engineering 4 Testing
19530.11=61ewood Drive
Humble, Texas 77338
Phone: (281) W-6603 FAX: (3131) 5404966
Website:ai•ww:forceengineeringlesling.com
Product Evaluation Report
CARPORTS ANYWHERE
Hampton Rib Roof Panel over open framing
Florida Product Approval # ZM2.1 R2
Florida.Building Code 2020
Per Rule 61G20-3
Method: 1.—D
Category: Structural Components
Subcategory: Roof Deck
Compliance Method: 61G20-3A05(1)(d)
NON HVHZ
Product Manufacturer:
Carport Anywhere
10858 S.E. County Road 221.
Starke, Florida 32091.
Engineer Evaluator:
Johnathan Green, P.E. # 88223
Florida Evaluation ANE ID:12901
Validatorb
Brian Jaks, P.E. #70159
Contents'
Evaluation Report Pages 1.4
Y SIGNED AND
3YJOHNATHAN
IN THE DATE
IT TO THE:SEAL.
):COPIES OF THIS
:NT ARE NOT
:RED SIGNED AND
AND THE
)RE MUST BE
ON ANY
FL# 27402.1 R2
t 4
_1 Force Engineering & Testing
19530 Ramblewood Drive
Humble, Texas 77338
Phone: (291) W-6603 TAX: (281) 540-9966
Vycbsite: ii,iviv.forceengineeringiesting.eom
Compliance Statement; The product as described in this report has demonstrated compliance with the
Florida Building Code 2020, Sections 1504.3.2;1504.7:
Product Description: Hampton Rib 26 Ga. and 29 Ga. Steel Roof Panel, 36" Wide; through fastened
structural roof panel. Structural Application.
Panel Material/Standards: Material:
26 Ga. Steel, ASTM A792 or ASTM A653 G90 Grade 50
19Ga. Steel, ASTM: A792 or ASTM A653 G90 Grade 80
Conforming to Florida Building Code 2020 Section 1507.4.3. Optional. paint finish.
Corrosion Resistance: Panel Material shall.comp.ly with Florida Building Code
2020, Section 1507.4.3.
Panel Dimension(s) Thickness: 26 Ga.: 0.0185" min. order thickness
29 Ga.i 0.014V' min. order thickness_
Width: 36"maximum coverage
Rib. Height: W major rib at 9" O.C.
Panel Rollformer: MRS Metal Rollforming Systems
Panel Fastener: #12-14 x %" HWH SD#3 with 14mm,neoprene bonded washing or approved equal.
Corrosion Resistance: Per Florida Building Code 2020. Section 1507.4.4;
Substrate Description: Minimum 14 Ga; (Grade 50) Steel framing, Minimum 16 Ga. (Grade 50);Steel
framing, or Minimum 18 Ga. (Grade 50) Steel framing. See Table A & B for steel
gauge. Framing must be designed in accordance w/ Florida Building Cade 2020.
Allowable Design Pressures:
Table "A" 26:Ga. Hamoton Rib Roof Panel
Maximum Design Pressure:
757:3 psf
-72.9 psf
-67.7 psf
+46.9 psf
+54.7 psf
Panel Fastener Pattern:
2=1-2=1
2-1-2-1
2-1-2-1
2-1-2-1
2-1-2-1
Panel Span;
514" O.C.
4'-0" OX;
4.'4 O.C.
51-W O.C.
4'-0" O.C.
Substrate:
Min.14 Ga.
Steel Framing
Min.14 Ga.
Steel Framing
Min.14 Ga.
Steel Framing
Min.18 Ga:
Steel Framing
Min.18 Ga.
Steel Framing
*Design Pressure Includes a Safety Factor = 2.0.
a ok GB'M3 e
° e
8'mm CIF °
01
\fit
A/�d01P81 il��t�
FL# 27402.1 R2
THIS ITEM HAS BEEN
DIGITALLY SIGNED AND
SEALED BYJOHNATHAN
GREEN ON THE DATE
ADJACENT TO THE SEAL.
COPIES OF THIS
:NT ARE NOT
°RED SIGNED AND
AND THE
IRE MUST BE
) ON ANY
U Force Engineering & Testing
19530Ramblewood Drive
Humble, Texas 77338
Phone: (281) $40-6603 FAX: (281) 54i0-9966
Websile: www.forccengineeringlesting,cont
Table "B" 29 Ga. Hamoton Rib Roof Panel
Mazimum:Design Pressure:
-57.3 psf
-150.9 psf
+39.0 psf
+143.1 psf
Fastener Pattern:
Fastener Spacing.
4'-0" O.C.
21-01,b.C.
4'4' O.C.
T-D" O.C.
*Design Pressure includes a Safety factor= 2.0.
Code Compliance: The product described herein has demonstrated compliance with
The Florida Building Code 2020, Section 1504.3.2,1504.7.
Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load
requirements of the Florida Building Code 2020, asrelates to. Rule 61G20-3.
Performance Standards: The product described herein has demonstrated compliance with:
■ ASTM E 1592-05 (2012) Test method for structural performance of
sheet metal roof and siding systems by uniform static air pressure
difference
■ FM 4471-92 - Foot Traffic Resistance Test
Reference Data: 1. ASTM E 1592-05 (2012) Test
force Engineering & Testing, Inc. (FBC Organization # TST-5328)
Report No. 667-0060T-18A-I! 667-0061T-18A-D
2. FM 4471-10, Section 4.4 Foot Traffic Resistance Test
Force. Engineering & Testing, Inc. (FBC Organization # TST-5328)
Report No. 667=0060T18F, 667-0061T 18E
3. Certificate of Independence
ByJohnathan Green, P.E. (No. 88223) @ Force Engineering &Testing
(FBC Organization #.ANE ID:12901
Test Standard Equivalency: 1. The FM'4471-10,'Foot Traffic Resistance test -standard is equivalent to
FM 4471-92.
Quality Assurance Entity: The manufacturer has establishedcompliance of roof panel products in
accordance with -the Florida Building Code and Rule 61G20-3.005 (3) for
.man ufacturing'urider a quality assurance program audited. by an approved
quality assurance entity.
�Q@9118 all./gys
LN 5R Bd��i
�pC�fb Z o
*'ea
Ii130 i r$�
® mcw a
���BGIQIIIII�A�!
FL# 27402.1 R2
THIS ITEM HAS BEEN
DIGITALLY SIGNED AND
SEALED BY JOHNATHAN
GREEN ON THE DATE
ADJACENT TO THE SEAL.
PRINTED COPIES OF THIS
DOCUMENT ARE NOT
CONSIDERED SIGNED AND
SIGNATURE MUST BE
VERIFIED ON ANY
ELECTRONIC COPIES.
1_1 Force Engineering & Testing �...
19530 Rumblewood Drive
`Humble, Tcxus 77338
Phone: (281) 5J0:6601 FAX: (281) 5404966
Welisite: rein• iv.forecenginceringtcsting.com
Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2020, including Section
1507.4.2 and in accordance with Manufacturers recommendations. For slopes
less than 3:12, lap sealant must be used in the panel side laps.
Installation: Install per manufacturer's recommended details.
Insulation: Manufacturer's approved product (Optional)
Roof Panel Fire Classification: Fire classification is not part of this acceptance.
Shear Diaphragm: Shearrdiiaphragm values are outside the.scope of this report.
Design Procedure: Based on -the dimensions of the structure, appropriate wind loads are
determined using Chapter 16`of the Florida -Building Code 2020 for roof cladding
wind loads: These component wind loads for roof cladding are compared to the
allowable pressure listed above. The design. professional shall select the
appropriate erection details to reference in his drawings for proper fastener
attachment to his -structure and analyze1he panel fasteners for pullout and
pullover. Support framing must be in compliance with Florida Building Code 2020
Chapter 22 forsteel; and Chapter 16 for structural loading:
��08bl81B99�g
N0�
ddCQR1�'•
GLAD 88=3 °iz
SUMOF
o�
i
e �c* �
FL# 27402.1 R2
ITEM HAS BEEN
'ALLY SIGNED AND
ED BY JOHNATHAN
:N ON THE DATE
CENT TO THE SEAL.
PRINTED COPIES OF THIS
DOCUMENT ARE NOT
CONSIDERED SIGNED AND
SEALED AND THE
SIGNATURE MUST BE
VERIFIED ON ANY
ELECTRONIC COPIES.
LI � 141
j Force E. mineering c4z Testing 4._ -
19530'Romhlcivood Drive
:Humble, Testis 7733H
Phone: (281) 540-6603'FA%:' (2Hi) 540.-9966
W0sitc. iF•1►N.Corcecuginceri6gi.diing.com
26 GA. HAMPT09 RIB FASTENER PATTERN 2-1-2-1
#12-14-x. 3/4` HNH-503 V// 14MM.BONDED NEOPRENE WASHER
29 GA. HAMPTON RIB FASTENER PATTERN
W, 3" 6" 6 3`
`012-14 x 3/4" HWH SD3 N/ 146A BONDED NEOPRENE SMASHER
-"...En en
THIS ITEM HAS BEEN.
DIGITALLY SIGNED AND
SEALED BY JOHNATHAN
3REEN ON THE DATE
ADJACENT TO THE SEAL.
PRINTED COPIES'OF THIS
DOCUMENT ARE NOT
CONSIDERED SIGNED AND .
SEALED AND THE
SIGNATURE MUST BE
VERIFIED ON ANY
FL# 27402.1 R2