HomeMy WebLinkAboutBuilding PlanRear Elevation
scale: 1/4 = 1'-0" — --
t Elevation
Front Elevation
scale: 1/4"" = 1'-0"
Safe Load Table Notes
1. All values based on minimum 4" nominal bearing.
Exception: Safe loads for unfilled U lintels must
be reduced by 20% if bearing length is less than
6 1/2".
2. N.R. = Not Rated
3. Safe loads are superimposed allowable loads.
4. One #7 rebar may be substituted for two #5
rebar in 8 inch U lintels only.
5. All safe loads in units of pounds per linier foot.
6. All safe loads are based on simply supported span.
7. Safe load ratings based on rational design analysis
per ACI 318 and ACI 530.
#5 rebor at top
ai (U req'd.
N
quant, of #5 rebar
at bottom of lintel
F= filled grout
T
t
a—
C.M. .
N width
l 1 E
,°
in =
8F16-1 B/1 T
cmfgroed
aatcrat°
J J
Intel
7 ':e eer°at bottom
ity
nominal rgebar et t°#5
heigth p
6"'Nominal
Lintel
Type
Designation
Flat Conc. Tile Roofing
over "Peel and Stick-
underlayment on 5/8"
c.d.x. plywood fastened as
per nailing schedule -�
Provide Metal Channels at
Hip and Ridge locations to
Support Cap Tiles
Spray Foam _
Insulation per
Energy Code
10'-0". � O.B.
1/2" d.w-/
1 x 4 p.t.
Firestop
Two Course Perimeter
Beam with (1) #5 Rebar
Filled with Grout each
course
1 x 2 p.t. furring
strips 24"O.c.-�
over 3/4" Insul.
Board
1/2- d
#5 Vert. rebar in
grout filled cell
See Floor Plan
for Locations
4- 3000# Fibermix Conc.
on .006 Visquine on Clean
Compacted, Termite
Treated Fill
0.00' �---T--.E.
0
M
•
F-1
Installation Notes
1. Installation of U lintels must comply with architectural
and/or structural drawings.
2. U lintels can be field cut to the required length.
3. Cast in place concrete may be provided in composite
U lintel in lieu of concrete masonry units.
4. The exterior surface of U lintels installed in exterior
concrete masonry walls shall have a coating of stucco
applied in accordance with ASTM C-926 or other
approved coating.
5. Concrete masonry units used in composite U lintel shall
be laid in a running bond.
6. Shore composite lintels as required.
7. U lintels are manufactured with a 5 1/2"" long notch at
both ends to accomodate vertical cell reinforcing and
grout.
Composite U Lintel Materials
1. Grout per ASTM C476 fg=3000 psi with maximum 3/8
inch aggregate and 8 to 11 inch slump.
2. Rebar per ASTM A615 Grade 60
3. Concrete masonry units (CMU) per ASTM C90 with
minimum net area compressive strength = 1900 psi
4. Mortar per ASTM C270 Type M or S
Pre Engineered Wood
Roof Trusses 24"o.c.
Shop Drawings by
Others
See Connector
/-Schedule
12 Galy. Drip Edge
over 1 x 3 p.t.
5
2 x 8 Cedar
/ Fascia
Stucco Soffit over
High Ribbed Wire
Lath Fastened to
Trusses, Provide (1)
Layer of #15 Felt on
Trusses under Lath
Provide Venting at
Entry Area
8x16x8
CMU Typ.
Stucco Finish over
Concrete Block.
#5 Vert. Rebar with
10- Hook and 30"
Lap. Tie to Vert.
Rebar In Cells
Grade
18" x 16"" 3000# Cont.
Conc. Mono. Footing with
(2) #5 rebars cont.
Typical Wail Section
c
I
Occupancy Type: Group R
Construction Type: V
Number of Stories: One
Project Area: 930 s.f.
Area Tabulation
Living: 750
Entry: 180
Total: 930
Design Loads
Roof Live Load: 20.0 p.s.f.
Floor Live Load: 40.0 p.s.f.
Wind Speed: 160 MPH
Wind Importance Factor: 1.0
Building Category: 11
Wind Exposure: B
Internal Pressure Coefficent: .18
Structure Designed: Enclosed
Soil bearing capacity: 2000 p.s.f.
Scope of Work
New One level CBS
Single Family residence
Building Code
2020 Florida Building Code: Residential
2017 National Electrical Code: NFPA 70
Climatic & Geographic Design Criteria
Weathering: Negligible Termite Area: Very Heavy
Flame Spread Index & Smoke Developed Index
Total Cubic Insulation Flame Spread: Not to exceed 25
Volume: 7,749 C.f. Insulation Smoke Developed Index: Not to exceed 450
Wall Finishes: Not greater than 200
Ceiling Finishes: Not greater than 200
Cast Crete Lintel Schedule
All Rehar to ha ##5 rrnrlP Rfl min
MARK
LENGTH OF
LINTEL
ALLOWABLE
GRAVITY LOAD
APPLIED
GRAVITY LOAD
ALLOWABLE
UPLIFT LOAD
APPLIED
UPLIFT LOAD
BEAM SPECS.
L-2
3'-0"
8974
167
5591
100
8F24-1B/1T
L-3
4'-6
3123
167
4292
100
8F24-1B/1T
L-4
6'-4-
2177
502
1340
315
8F12-1B/1T
L-5
4'-4"
8060
1597
4409
1126
8RF22-1B/1
3480
167
1880
100
81`16-1B/1T
1370
297
519
375
8F16-1B/1T
Min. Beam depths shown, beams may be increased without comment
At Lintels over 24" deep, provide (1) #3 vertical rebar
at 24"o.c. along length of lintel
1 T-84"
L-4 Coonn d.
9 60" x 20"
Fix. Glass
E
E v.t.r.
water
line
--
O
Ref.
O
Range &
Exh. Hood
10
0
T-2"" 6'-8„ -
3,_2„
3,
7,-7„
Kitchen
41
10'-0"" Cing.
10'-0""
d
Cling. b�,
i
E
❑
cc
I
r -�
1 I
❑,
co
—_-- --__a--
cV
�
---- --`�—
00
I
Temp. Glass W
on 42" Tall N
Walls L — I
E
2 x 4 Frame
34.5" Tall
2880
I 22.5 x 36
14
Pocket
2880
Attic
s.h.
I—
Living
I Access
Rm.
alL-2
10'-0" Cling. & 12"" Coffer
E
Master Bdrm.
I N
25
10'-0"" Ceiling
s.h.
I —
.
I
I
O
°
'
L-3
E
Electric
I ""
16'-9
Fireplace
HB
� ���
�
,M
E
14
I—
s.h.
HB
— — — — —
— — — —
❑
n
L-2 ^N
E
E
E E
E
E E
L-525
L=0"'COCODEntry
L-3
s.h.
Egress
10'-0"" Cling.
L-6
from F.F.E.
o
I
I
I
io
E ❑--------
------------ ❑ ❑
❑ ❑
I
❑ E
I
E E-------------
-------
E❑
Floor Plan
scale: 1/4" 1'-0"
%n
0)
Lul
z
et
*0
-
LL
In
�
Cc
U)
LLI
i
°
D
I
00
LO
LL
N
fl-
a../
nn�
6
U
z
ILIJ
aD
>
0
0
CC
a�
ls-
Ir,
C)
LLa
tti
n
CCj
C :)cli
oa
(
LL
LIJ
0
r-
V
Q
00
M
r
,-CEIVED
St. Lucie Cour>,
Perm:•"...
C
0
UJ
®
O�
0
D
ai
m
i
ro
.�.
J
Lu06o
0
cU
0
ED
F-
''
CD
M
rn
0
date revision
4/22/22
Plan Review Comment
Updated Building Code
Edition
drawn
s,.
checked
J.
date
1/14/22
scale
as noted
job number
22005
sheet
A-1
Flat Conc. Tile Roofing
over "Peel and Stick-
underlayment on 5/8"
c.d.x. plywood fastened as
per nailing schedule
Provide Metal Channels at
Hip and Ridge locations to
Support Cap Tiles
Spray Foam _
Insulation per
Energy Code
10`0" T.O.B.
11 '-4$
1 /2" d.wJ
1 x 4 p.t.
Firestop
Two Course Perimeter
Beam with (1) #5 Rebar
Filled with Grout each
course
1 x 2 p.t. furring
strips 24 o.c.—\
over 3/4" Insul.
Board
1/2- 1
#5 vert. rebar in
grout filled cell
See Floor Plan
for Locations
4- 3000# Fibermix Conc.
on .006 Visquine on Clean
Compacted, Termite
Treated Fill - \
0.00' 0� I E.
0
M
•
F-1
Pre Engineered Wood
Roof Trusses 24"o.c.
Shop Drawings by
Others
See Connector
Schedule
Galv. Drip Edge
over 1 x 3 p.t.
2 x 8 Cedar
Fascia
Stucco Soffit over
High Ribbed Wire
Lath Fastened to
Trusses, Provide (1)
Layer of #15 Felt on
Trusses under Lath
Provide Venting at
Entry Area
8x16x8
CMU Typ.
Stucco Finish over
Concrete Block.
#5 Vert. Rebar with
10- Hook and 30-
Lap. Tie to Vert.
Rebar In Cells
ItI Grade
18" x 16" 3000# Cont.
Conc. Mono. Footing with
(2) #5 rebars cont.
Ty icaI Wall Section
Building Data
Occupancy Type: Group R
Construction Type: V
Number of Stories: One
Project Area: 930 s.f.
Area Tabulation
Design Loads
Roof Live Load: 20.0 p.s.f.
Floor Live Load: 40.0 p.s.f.
Wind Speed: 160 MPH
Wind Importance Factor: 1.0
Building Category: II
Wind Exposure: B
Internal Pressure Coefficent: .18
Structure Designed: Enclosed
Soil bearing capacity: 2000 p.s.f.
Scope of Work
New One level CBS
Single Family residence
Building Code
2017 Florida Building Code: Residential
2014 National Electrical Code: NFPA 70
Living: 750
Entry: 180 Climatic & Geographic Design Criteria
Weathering: Negligible Termite Area: Very Heavy
Total: 930
Flame Spread Index & Smoke Developed Index
Total Cubic Insulation Flame Spread: Not to exceed 25
Volume: 7,701 c f. Insulation Smoke Developed Index: Not to exceed 450
Wall Finishes: Not greater than 200
Ceiling Finishes: Not greater than 200
FDOH in St. Lucie County
Environmental Health
Site Plan Approved for Construction
Supercedes All Previous Site Plans for
OSTDS#.S�-SW--- �2L-i0�'Jr11
96MIF 0,16
�. �� .�•.• it
Ri,aht Elevation
Left Elevation
scale: 1/4" = 1'=0"
Floor Plan
scale: 1/4" = 1'-0-
Rear Elevation
scale: 1 /4" = 1'-0-
U
0L
:3
o
U)
cv
rn
P�am,
`./
C")
Ci
LL
LO
U)
Q00
e
LLJ
C]
L
a.
I
o00o
J
�
N
_<
ai
U
L
LLJ
u
>
0
Cl
_I
va
o
LLJ
Ds
m
�
1�
f)
O
QC
LL
LLJ
�)
®
qd
w
U)
(/)
O
LLJ
H
U)
LL]
w
LLJ
C7
all
si
checked
.A.
date
12/12/2020
scale
as noted
job number
21072GH
sheet
A-1
gfi R
soffit + Flood
mount Light
_.ectrical Plan
scale: 1/4" = l'-0"
ELECTRICAL LEDGEND
{10 RECESSED LIGHT WITH LENS r4 EXTERIOR & WET LOCATIONS
i SURFACE MOUNTED LIGHT FIXTURE
I) SURFACE MOUNTED FLUORESCENT LIGHT FIXTURE
UNDER CABINET FLUORESCENT FIXTURE
FED] RECESSED INCANDESCENT LIGHT FIXTURE WITH EXHAUST FAN
CEILING FAN
O\�V\ EXHAUST FAN OUTLET ® DOOR CHIMES
THERMOSTAT SMOKE & CARBON
MONOXIDE DETECTOR
DUPLEX OUTLET - SWITCHED
-I+ TELEVISION
DUPLEX OUTLET
.0 TELEPHONE
220 V OUTLET
-yr SWITCH El PUSH BUTTON
_t/ THREE WAY SWITCH -.yln DIMMER SWITCH
NOTE: RECEPTACLES IN KITCHEN & BATH AREAS TO BE 46" A.F.F
ALL 120V SINGLE PHASE 15 8,20 AMP BRANCH CIRCUITS SUPPLYING
OUTLETS THAT ARE NOT GFCI MUST BE AFOL
TAMPER PROOF RECEPTICALES MUST BE INSTALLED IN 120 VOLT, SINGLE
PHASE 15 & 20 AMP BRANCH CIRCUITS
ALL LIGHTING TO BE L.E.D
Electrical Notes
1. All loads to be checked by a Florida Licensed Electrician
2. All work to meet the National Electrical Code
3. Calculations and panels below are for sizing conduit and overall
building load requirements only
4. Ensure min. 36- clear between equipment and disconnects, Typical.
5. Protective ratings shall comply with NEC 110-9 & NEC 110-10
6. Ensure panels have main disconnect at meter pack per NEC 230-70-A-1
Smoke detectors wired to 120V Bathroom lights
Non Switchable, Non GFI
Electrical contractor to verify all equipment loads prior to
start of construction. Electrical contractor to recalculate
electrical schedule if loads are to be modified
3-Nipple with (2) sets _
paralleled 1/0 THHN Cu.
Service
01
wp
1f gfi
Flood � soffit
Light mount
Electrical Load
Callas
FORMWORK & SHORING
No structural concrete shall be stripped until it has reached at least 80% of
750 Living S.F.at 3 VA
g
2,250 watts
the 28 day design strengtn.
Two 20 Amp Appliance Ckts.
3000 watts
Design, Erection, & Removal of all formwork, shores, & reshores shall meet
One Laundry Circuit
1500 watts
meet the ACI Standards 347 and 301
Exhaust Hood
800 watts
One Ref.
1500 watts
Contractor to verify all building setbacks prior to the start of construction.
A formboard survey shall be submitted to the building department for
Range
8000 watts
approval prior to pouring concrete.
One Microwave
2000 watts
One Disposals
1500 watts
SOIL STATEMENT:
One Bath
1500 watts
Foundation has been designed for a soil bearing capacity of 2000 p.s.i.
Detached Garage
1500 watts
Fill shall be laid in layers of 6-. Each layer to be compacted to 95%
compaction.
Total
21,550 watts
If the contractor encounters, while digging the foundation, any
discrepancy to suggest the soil may be inadecuate, he must
First 10 KVA at 100%
10,000 watts
immediately report it to the owner and the Architect or Engineer
so as to order a soil boring test.
Remainder at 40%
4,620 watts
Total
14,620 watts
GENERAL FOUNDATION NOTES
One AC Heat at 100%
8,000 watts
Concrete shall be a minimum of 4"' thick over clean, compacted,
Total
22,620 watts
termite treated fill and 6 mil polyethylene vapor barrier.
If concrete slab contains 6" x 6'" 10/10 WWM provide 1" coverage
22,620 W / 240 V = 94.25
Amps
Concrete shall have at minimum compressive strength of not less
than 3,000 p.s.i. c
Use 125A Service
All 90% hooks are to be extended 10"' minimum beyond the turn.
Field bends are to be done cold and the diameter of the bend,
measured on the inside of the bar, is not to be less than six
bar diameters.
Minimum coverage for rebar shall be 3"" in footings and 1 1/2" in
bond beams. Hooks may be rotated horizonitally if required to
achieve minimum coverages.
Rebar overlap shall be 48 bar diameters. 30" for #5 rebar
The foundation design assumes that the soil has a minimum
load carrying capacity of 2000 p.s.f.
In the event the soil bearing capacity falls below 2000 p.s.f. This
foundation plan may be superceded by Foundation Design Engineer.
Satisfactory compaction test of fill does not verify lower soils are
adequate.
All specifications and dimensions to be verified by contractor.
All exterior slabs shall slope a minimum 1 /8"" per foot for drainage
150A 150A 125A
Disc. C.
Disc.
O O O
#1/0 Cu
GEC
Dowel Rod Repair Note
In the event vertical steel has been omitted from the down
pour locations, drill 5" into concrete (no closer than 3 3/4-
from edges and 5" from ends of cap walls) Remove dust
per manufacturers instructions and use Two part epoxy to
anchor the #5 rebar in place. Use either "Hilti C-100" or
Simpson Epoxy -Tie.
2 v.t.r.
1 1/2"Conduit with (3)
1/0 THHN Cu. (1) #6 Green
125A 150A Fel#1
0A
Sub Panel 30 Ckt. Ckt.
to Guest
House Panel #2
I_ 1 1/2"Conduit with (3)
#1 THHN Cu. (1) #6 Green
1Q Nipple with (3) 1/0 THHN Cu. (4) #6 Green Cu.
2O Nipple with (3) 1/0 THHN Cu. (1) #6 Green Cu. Main Residence
Guest House
Nipple with (1) #1 THHN Cu. (1) #6 Green Cu.
Service to be 350 Amp
120/240 V Residential Service
Ammended Riser to include:
Main Residence Load Cafes: 217.0 Amps
Guest House Load Calcs: 94.17 Amps
Total: 311.17 Amps
Build Service to be 350 Amps
5/8" dia. x 8' CU clad
ground rod &CUwater places) M
pipe ground (Typ. 2 places) House Elec. Riser Diagram
Plumbing contractor to provide a
water hammer & shut off valve at
each fixture
Insulate all hot water lines
Plumbing Riser Diagram
PLUMBING NOTES:
O F-1 O O O
O F-1 O
o
o
o
co
O
F-3
O
C4
N
I
`v
�n
'v
0
El
T-2" 10'_8 t 3'-7"
0
M
I
O
N
N
I
O
F-1
4" 3000# FIBERMIX CONC.
OVER .006 VISQUINE ON CLEAN,
F-1
COMPACTED TERMITE TREATED
Q
ih
FILL
0
0.00' Assumed F.F.E.
M
1
'v
See Civil Drawings for
the established F.E.E.
SE
in
F-2
O
O FIRF-2 R O 0 O
O
-4„
F_1
6'-10""
6'-11'"
F-1
00
,
1 'v
o
�t
o
O❑
F-1
❑
❑
F-1
❑O
❑o
00
0❑
to sanitary
system Foundation & Footin_
s
scale: 1 /4" = 1'-0"
Plumber to consult with contractor and equipment ordered
for rough in dimensions.
Verify all dimensions with the floor plan. The floor plan
dimensions dictates all other dimensions on other sheets.
Do not scale drawings, if any conflicts arise, contact the
Architect or Engineer for clarification prior to construction
All sanitary lines 2" or less shall have a slope of 1/4- per
foot minimum.
All sanitary lines above 2- shall have a slope of 1/8" per
foot minimum.
Provide Anti -Scalding Valve in all showers
Lowest living area floor elevation (refered as 0.00') to be
set by a professional land surveyor to the required building
department elevation, but not less than 18" above the crown
of the road.
Plan
F-1 I F-2
16- x 18" mono. footing
with (2) #5 rebar cont.
16"
18" x 18" mono. footing
with (2) #5 rebar cont.
4:'
4"
18 10""
18"
MONO. EDGE FOOTING
F-3
Recess 4" at Shower
4„ 4„
4"
Reber
TYP. SHOWER
RECESS
STEP FOOTING
comer bars at beam
(outside only) (2) corner
bars at footing (min.) —
vert. dowel lapped with
wall reinforcing, all
laps 30- (min.) in grout
filled cell
all corner bars to be the
same size, number, and
spacing as horizontial bars
in footing, beams, and walls
Corner Reinforcing Detail
U
e.-.a
Q.
o
w
L,
' R
UJ
ZLL
M
bO
N
U
�
• �
w
0
N
it
LO
00
0
J
V'
r
n
Z
Z
n
�
w
>
�
O
In
LIJ
M
VJ
ICU
F_
¢
CTJ
LO
I+
`O
N
LW
r
CD
O
i
tp00
r
00
z
O
W
N
r
�
Ix
fir`
v
00
T
0
VJ
LU
N
r
-J
mLu
R
(4
0
03
ZE
y4)
L
M
w
0
r
drawn
S.I.
checked
s.l.
date
1/14/22
scale
as noted
job number
22005
sheet
' n
.
.,n_4µ„
STRUCTURAL NOTES:
All reinforcing steel shall be high strength billet steel and shall
conform to ASTM A-615 grade 60 specifications. Lap continuous
reinforcing 48 bar diameters or 30- in beams and in slabs. Lap
bottom steel over supports and top steel at midspan. Hook
discontinuous ends of all top bars. Reinforcing steel shall have
a minimum of 1- concrete cover, or as follows:
BOTTOM TOP SIDES
Beams: 11/2- 11/2" 11/2"
Slab on Grade: 1 1/2- 1" _
Structural Poured: 3/4" 3/4- _
Poured Walls: _ _ 3/4-
Slabs exposed
to the weather 3/4" 1
Reinforcingsteel shall be detailed and fabricated in accordance ab cated acco da ce
with the "Manual of Standard Practice of Detailing Reinforcing
Concrete Structures"" and the current -ACI Building Code 318"
All structural steel shall conform to current ASTM Specification A-36
All wood in contact with masonry shall be pressure treated or approved
seperating material.
All dimensions shall be verified in field by the contractor. If there are
any discrepancies the Architect or Engineer shall be notified before
proceeding.
No slump over 5" shall be permitted for any structural concrete without
the Architect or Engineer approval.
All Design and Construction shall be inaccordance with the current
American Concrete Institute (ACI). and the American Institute of Steel
Construction (AISC), The Florida Building Code and all applicable
local codes.
Structural Concrete shall attain a minimum ultimate compressive strength
(Fc') in 28 days as follows:
Column Footing and Wall Footing: 3000 p.s.i.
Column and walls from foundation to roof: see column schedule.
All other concrete: 3000 1
Footing sizes and reinforcing are based on allowable soil bearing
capacity of 2000 p.s.i. All footings shall bear in virgin soil. If this
is not the case, the Architect or Engineer shall be notified before
proceeding with the work.
Timber (Heavy Timber Construction)
(a) Truss manufacturer shall submit a signed and sealed shop
drawings by a registered Engineer.
(b) Wood rafters to have a Stress Grade of Fb=1200 1
(c) Roof members should be secured to the beams or other
structural components with hurricane anchors for wind uplift.
All wood members shall have a minimum fiber stress in bending
of 1200 p.s.i. with 1 /360 max. deflection.
All bolted connections shall be 1/2" Cadmium plated or better.
Lag bolts to be used only in shear connections with minimum
4" threaded penetration past steel plate.
Lag bolted conditions shall be drill tapped no larger than the
internal thread diameter and shall not be hammer driven.
Under Girder Trusses provide equal number of studs as girder
plys at frame bearing locations
GENERAL REQUIREMENTS
All work to be as per the current edition of the Florida Building Code
and meet or exceed all applicable local requirements.
General contractor is responsible for all labor, materials, utilities, testing,
waste removal, storage, securing of site, accomodation, transport/freight,
and all other cost related to the completion of this project., unless explicitly
identified here.
Owner is responsible for all municipal related charges such as impact
fees, and water connection, except building permit fees, which are to be
included in the construction bid.
General contractor to check all drawings for errors and ommissions and
bring them to the attention of the architect prior to starting any work, or
ordering any materials of the respective division of work. If such errors
and ommissions are not reported in writingto the architect, any resulting
damages or costs shall be born entirely by the general contractor.
Architect is not responsible for the contractors method or means of
construction.
General contractor is to keep the site in a clean and safe state through
out the course of construction. On building turnover, general contractor to
clean all surfaces so as to be free of dust, grease, stains, scuffs, etc.
Unless otherwise noted, the installation of specified hardware shall
conform to the manufacturers instructions and standard practice.
All plans and drawings are not considered complete until they have been
reviewed and approved by the Building Department
and the building permit has been issued.
EXTERIOR CEILING & SOFFIT NOTE
7/8" Stucco finish over 3/8" high ribbed galv. wire lath fastened to
framing members with No. 11 guage nails with 1 3/4" embed. with 3/8-
dia. head 6"o.c. max, edges to be tied and nailed at 9-o.c.
Install one layer of 15# felt to framing prior to installing ribbed lath
INTERIOR WALL FRAMING NOTE
Interior non bearing walls to be 2 x 4 studs 24"o.c.
Spruce, Pine, Fir (SPF) #2 Grade lumber or better
or metal studs (25 Ga.) Crimper may be used in
lieu of screws.
THRESHOLD NOTE
At egress door (see floor plan) the max. hgth.
of the threshold shall be 1/2"
BUCK ATTACHMENT NOTES
AT DOORS USE P.T. PINE OR SPRUCE AND ATTACH
TO BLOCK WITH 1/4" DIA. TAPCONS INTO C.B.S.
SET AT 6" FROM CORNERS AND AT 12" o.c. MAX.
AT WINDOWS USE P.T. PINE OR SPRUCE AND ATTACH
BUCKS TO BLOCK WITH 8d CASED HARD COIL NAILS
OR "T- NAILS" 4- FROM ENDS AND 12-o.c.
USE WOOD SHIMS MINIMUM DURING DOOR INSTALLATION
GENERAL ROOFING NOTES
Roofing to be composed of and attached to pre manufactured
wood trusses as follows:
Felt underlayment (min. ASTM 0 226 Type II) with 4" min. side and
end laps, fasten with coorosion resistant annular ring shank nails
at 6"o.c. in laps and in staggered rows spaced 12""o.c. in field.
If roof pitch is < 4/12 install (2) layers 15# felt.
If roof pitch is 4/12 or greater, install (1) layer 30# felt.
5/8" c.d.x. sheathing or equal installed with staggered joints & GI clips,
nailed to trusses with 8d corrosion resistant annular ring shank nails
spaced max. 6"o.c. throughout, except max. 4"o.c. at gable ends.
All roof trusses are to be pre -manufactured assemblies provided by
a licensed wood truss fabricator with seperate drawings and data
prepared for actual projectconditions by a Florida registered
professional engineer certified for truss design. Any deviation from
the proposed plans as shown regarding placement or bearing shall
be brought to the attention of the truss engineer prior to fabrication
of the trusses. The truss manufacturer's certified layout shall govern
after fabrication.
The handling, erectioi, and fixing of wood trusses shall be in
accordance with the specifications contained on the certified mfgr's.
drawings and data.
All engineered headers and truss hangers to be provided by the
truss manufacturer.
Splitting or cracking of structural components due to installation of
hardware is not perrritted.
Unless otherwise noted, the installation of specified hardware shall
conform to the truss manufacturers installation instructions and
standard practice.
SHEATHING NAILING NOTES
Nailing Pattern
Zone 1: 8d at 6"o.c. field 8, 4"o.c. edges
Zone 2E & 21 8d at 4" o.c. edges & field
Zone 3: 8d at 4"o.c. edges & field
Pneumatic Nails
Pneumatic or mechanicaly driven nails will
be accepted under the following conditions
Min. nails size 8d or larger ring shank with
Min. shank diameter:.113
Min. Length: 2-
Min, Head Diameter:.280 Full Round
Min. Ring Diameter .012 over shank dia.
Min. 16 to 20 Rings per Inch
Note
Gun nails shall be permitted as an
acceptable fastenerfrom any manufacturer
Wood screws meeting the same size requirement
may be used in lieu of nails without comment
Nailina Schedule
ROOF & FLOOR DIAGRAM
Use sheathing with #8 gun nails at 6"o.c.
at supported panel edges and #8 gun
nails at 6" o.c. at intermediate supports.
ROOF SHEATHING TO GABLE END FRAME
Use #8 gun nails at 4"o.c.
EXTERIOR SHEATHING
Use #8 gun nails at 4"o.c. at panel edges
and #8 gun nails at 4-o.c. at panel top and
bottom and 6" o.c. in field
Wire Lath Attachment
Over wood framing the paper
backed wire lath shall be installed
over one layer of approved plastic
house wrap. Lath shall be attached
horizontal framing members with 1.5"
roofing nails and to vertical wood
framing members with 6d common
nails or 1 " roofing nails driven to
penetration of not less then 3/4"
of an inch, or I' wire staples
driven flush with the plaster base.
Staples shall have crowns not less
than 3/4"" and shall engage not less
than three strands of lath and
penetrate the wood framing members
not less than 3/4"". The fasteners must
penetrate the wood framing members
not less than 3/4". Fasteners shall be
7"" o.c. max.
IAI:.-J 7-._-_ 1A!_II_
Roof Wind Zones
Ceramic Tile
Shall be installed in accordance with ANSI A108.1, A108.4, A108.5
A108.6, A108.11, All 18.1, Al18.3, A136.1, & A137.1. Fiber mat reinforced
backer shall be used behind wall applied ceramic tiles in the tub
and shower areas and conform to ASTM C1325. Per Durock,
cement board exceeds ASTM C1325.
Gypsum Note
Gypsum board shall conform to ASTM C22, C475, C514, C1002, C1047
C1177, C1178, C1278, C1396, or C1658 and installed per FBC residential
code. Per USG, Wallboard conforms to C1396.
Gypsum Board & Gypsum Panel Products
Gypsum board and gypsum panel products shall be applied
at right angles or parallel to framing members. All edges and
ends of gypsum board and gypsum panel products shall
occur on framing members, except those edges and ends that
are perpendicular to the framing members. Interior gypsum
board shall not be installed where it is directly exposed to
weather or to water.
Wall and ceiling gypsum board shall be fastened with screws
spaced at 12""o,c. Screws for attaching gypsum board and gypsum
panel products to wood framing shall be Type W or Type S in
accordance with ASTM 01002 andshall penetrate thewood not
less than 5/8"" inch (15.9mm) Gypsum board and Gypsum panel
products shall be attached to cold formed steel framing less
than 0.033" (1 mm) thick shall be Type S in accordance with
ASTM C1002 or bugle head style in accordance with ASTM C1513
and shall penetrate the steel not less than 3/8"" to 0.112-
(1mm to 3mm) thick shall be in accordance with ASTM C954 or
bugle head style in accordance with ASTM 1513. Screws for
attaching gypsum board or gypsum panel products to structural
insulated panles shall penetrate the wood structural panle facing
not less than 7/16"o.c. (11.1mm).
Gypsum board used as the base orbacker for adhesive application
of ceramic tile or other required nonabsorbent finish material shall
conform to ASTM C1396, C1178, C1278. Use of water resistant
gypsum backing board shall be permitted on ceilings. Water
resistant gypsum board shall not be installed over a Class 1 or
Class 2 vapor retarder in a shower or tub compartment. Cut or
exposed edges, including those at wall intersections, shall be
sealed as recommended by the manufactuer. Water resistant
gypsum backing board shall not be used where there will be
direct exposure to water, or areas subject to continuous high
humidity.
Cold Formed Steel Note
Cold formed steel framing supporting gypsum board and gypsum
panel products shall be not less than 1 1/4" (32mm) wide in the
least dimension. Non Load bearing cold formed steel framing
shall comply with AISI S220 and ASTM C645, Section 10. Load
bearing cold formed steel framing shall comply with AISI S200
and ASTM C955, Section 8.
Wood Framing Note
Wood framing supporting gypsum board and gypsum panel
products shall be not less than 2"" (51mm) nominal thickness
in th least dimension except that wood furring strips not less
than I- by 2" (25mm x 51mm) nominal dimension shall be
permitted to be used over solid backing or framing spaced
not more than 24"o.c. (61Omm)
Roof' Fr min n
Alum. window
frame
3/8- continuous bead of
caulk (back bedding) behind
shim to prevent liquid passage
1/4- struct. shi
set flange in continuous
bead of caulk across the
entire face of buck
perimeter caulk
stucco finish �
Gunable sealants shall comply with °
ASTM C 920 Class 25 grade or a.
greater for proper joint expansion
and contraction
precast
cone. sill
2 x 4 bottom cord bracine
corrosive resistant
Tapcon concrete
screws installed as
specified in window
manufacturers product
approval
window sill
Typical Precast Conc. Sill Detail
Bottom Cord Lateral Braci
Connector Schedule
Truss
Bearing
Truss
Connector
Qnty.
Connector
Fasteners
Point
Uplift
ID
Uplift
A08G
16
682
HETA16
1
1810
(9) 10d x 1 1/2"
1 Fly
10
620
HETA16
1
1810
(9) 10d x 1 1/2"
All other
trusses
ALL
<9900
MTS16
1
990#
04) 1Od x 1 1/2"
to Frame
All other
trusses
ALL
<1810
HETA20
1
1810#
(9) 10d x 1 1/2"
to CBS
Valley
Supporting
Framing
(4) 1Od
Trusses
<250#
VTCR
1
370#
valley
Truss
(3) 10d x 1 1 /2'
Connector Schedule Developed from the Truss Placement
Plan and Engineering from East Coast Truss Company
Job Number J43061 Dated 11/9/21
3/8"" continuous bead of
caulk (back bedding) behind
buck to prevent liquid passage
set flange in continuous
bead of caulk across the
entire face of buck -
hilly
a
a
d 4:
a
d' a a
LWM200 Waterproof
Coating on the inside of
the Jambs, Head & Sill
min. 8"
M
stucco finish
perimeter caulk
Attach p.t. bucks
with 8d coil nails at
12""o.c.
Typ. Alum. window _
jamb or sliding glass
doorjamb
Min. 1 1/4"" embedment
at windows and min.
1 1/2"" embedment at
sl. gl. doors
drywall
1/4" max. struct. shim
caulk
attach as per
manufacturers
product approvals
NOTE: Method of attachment and Gunable sealants shall comply with
waterproofing procedures are the ASTM C 920 Class 25 grade or
same at poured concrete sill. greater for proper joint expansion
and contraction
Coat Bucks with LWM200 Waterproofing
after they have been installed and Chaulked
Window & Door Flashing Detail at CBS Wall
U
a
Q
cV
M
00
W
Z
c7
_I
W
y�
VIA/LU
�
U
�
0
00
®
J
lL
N
Q
Oj
n
Z
N
d
v
v
W
0
"�
fn
O
W
M
ui
Includes Buck Attachment Method
Connector Notes_
Do not substitute connecters
U
a' ,-
Lo
C
Do not sheath trusses before all straps are in place
> W
F-
ca
o V
N
Attach valley trusses and piggy back trusses, if present,
� y
I..L. _
FuCO
CD Z
o
c.l
to main trusses per truss manufacturer drawing.
CW
Truss to truss connection by truss company, installed
m<
00
Cn
per manufacturers spec's.
N
L�
Lateral forces perpendicular and parallel to wall has been
considered (less than 300 p.l.f.)
Contractor to approve temporary bracing to prevent toppling
of trusses, see HIB-9.
Other specs, if different from above, have priority.
A.T.R. = All Treaded Rod
�
Drill and Epoxy Set all A.T.R.
U
Use either "Hilti" C-100 or Simpson Epoxy Tie Epoxy
Of
Of
°'
Provide equal number of studs under girders equal to
W
N
J
the number of plys.
0
N
Missed Tie Down Strap Note
�
00
to
ai
In the event the Tie Down Strap has been omitted from the
LU
(n
06
o
Layout location, install one MTS18 strap at the proper location.
v
Fasten with (4) 1/4"" x 2 1/4"" Hex Head Titen screw to C.B.S.
J
and (7) 10d x 1 1/2" to truss. MAXIMUM UPLIFT 1000 lbs.
WH
O
co
rn
0
Product Approval Affidavit Form
Category
Subcategory
Approval
Numbers
Manufacturer
Model Number
Glass
Type
Attachment Method
Building Design
Pressures
Product Rated
Design Pressures
A. DOORS
Swinging
FL#: 10597.9
CGI
7700
Impact
from corners & 6 "" ""& 10"" from Astragal. Jambs:
Head & Sill: 4&below lock ¢er between
9 1/2""from corners & fi""above
the hinges. Use 1/4"" Tapcons with 1 3/4" embed. in concrete.
+38.7 -50.0
+/- 50.0
B. WINDOWS
Singlehung
FL#: 90645
CGI
7100
Impact
Jambs: 6.5"& 9.5"max. from corners & 4""& 16.5"max. on each
side of the meeting rail.
Use 1/4-Tapcon with 1 1/4" embed. into concrete
+38.7 -50.0
+60 / -60
Fixed
FL#: 9063.7
CGI
7500
Impact
Head & Sill: 6" from corners and 7"o.c. Jambs: 6" from
corners and 7" o.c. Use 1/4" Tapcon with 1 1/4""
embeded into concrete
+38.7 -50.0
+/- 50.0
D. ROOFING
Roof Tiles
FL#: 7849.4
Boral Tile
Flat (Bermuda)
Adhesive Set
-45.0
-65.2
-102.3
-135.0
Underlayment
FL#: 5259.1
Polyglass USA
Polystick TU Plus
Direct bond to deck
drawn
SA.
checked
.A.
date
1/14/22
scale
as noted
job number
22005
sheet
A-3
r