Loading...
HomeMy WebLinkAboutFloor-Foundation Plan- Planning & Development Services Department - - e Building &Code Regulations Division - - - I. - MINIMUM 6" TS NIPPLE. NIPPLE MINIMUM 6" TS NIPPLE NIPPLE MINIMUM 6" TS NIPPLE. NIPPLE ,.. - 2300 Virgir(ia Avenue, Fort Pierce, FL 34982 -(772) 462-1553 SECURED TO WALL POST WITH ' SECURED TO WALL POST WITH SECURED TO WALL POST WITH Certification for De sign Load Compliance - (4)#12-14x�"SELF-DRILLING SC)EWS 116 SELF -DRILLING - (4)#12-14xi" SELF -DRILLING _ SCREWS SCREWS 2"x2"x2" 16 GA. ANGLE CLIP Project Name: WEBB CARPORT'. - NIPPLE TO 2"x2"x2" i6 (;A. ANGLE CLIP _ SECURED WITH (4) #'12-14xi" 14 12 - BASE RAIL NIPPLE T" SECURED WITFI (4) #12-14GA.SELF-DRILLING SCRE-WS Project Address: 4418PRESSLERLIN - `� BASE RAI SECURED WITH (4)N#12-14x#" SELF -DRILLING SCREWS -��,r SELF -DRILLING SCREWS HEADER SINGLE OR DOUBLE TS - - Permit p: Oce Pancy Type: R Construction Type: V - III:I1 11:: =11 1 ,I 1 III - III= �_ SINGLE OR DOUBLE TS - INSTRURIONSFORUSE II = ), 1I1-ITI-1 �!--,-III I'!T' II,I I _ _�._� =. NIPPLE T HEADER /� BASE RAIL^ INTERMEDIATE POST TO I - -This certification must he completed, signed) and sealed by the design professional of record. - - Submit (2) New iesior restdencedentile or muld4aes mil commercial with all permit applications involving the following: O O BASE HEADER CONNECTION HEADER CONNECTION DETAIL _ -- p New Residences (single or mult4fa �' � - mily) POST TO BASE RAIL END POST T B RAIL HEADER BP,,:,.E RAIL Wf3 -- - oResidentfal Addition o Any accessory structure requiring building permit - - CONNECTION CONNECTION WI'��DOW RAIL DETAIL DETAIL OPTION 1 OPTION 2 — zls Ii 3 TL=a'L"9" — APPROVED PRODUCTS o Any non-residential structure, i -- � APPROVAL NO. GOOF SHEATHING carports Anywhere `Note: Form not required, for interior renovasions provided that no exterior structural elements are affected and - FL27402.� certain minor building permits at the discreti n of the local building official. Contact the q shove for questions. - - - 26 GAUGF ROOF SHEATHING SECURED WITH A HOmptOn Rib ROOF PQnel DESIGN PARAMETERS AND ASSUMPTIONS USIEb: (complete all that apply) - (1)#12--14x'i" SELF -DRILLING SCREWS ® NI PP LEA), 1. DESIGN CODE: Florida Building C.de120207th Edition with 20 _Supplements using ASCE 7-16 '2-1-2-1' (6". D.C. (9" O.C. MAX.)) TO TRUSS/ )' 2. Structure Designed as (check one): X Enclosed Partially Enclosed _Open 3. Risk Category: X1 :II_III_Iv- EIj,'posure Category: X B C_O 1 4. Design Wind Velocity 160 mph 12q ASD N/ALRFD End Zone Width 5 ft S. Mean Roof Height 15 it Roof Pitch: 4 :12 Parapet: N/A Ft - - _ - - MINIMUM 6" TS NIPPLE. - - _ NIPPLE SECURED TO WALL ' 16.0 Design Pressures used: (PSF, based on IOsgh @ 15'MRH, clearly label on all plan openings): : � - - POST WITH 4 12-14x�" : 6 16.0 16.0 27.6 27.6 26.2 - - O# Zone 3: Zone 4: Zone S: Garage: `' "- SELF -DRILLING SCREWS , 1" 16 GAUGE FURRING CHANNEL Zone Desi n loads: Floor: 2. -44A ad; -30.0 -Bale -34.1 48' C.C. MAX. SECURED WITH 6. Components & Cladding Zon 26_3 g : N/A PSF Roof/D6aTN/A PSF Roof/Live: N/A Balcony:. N/A PSF / .B /I,r t [4&, _ (2)#12-14xl" SELF -DRILLING Dock: N/A PSFDecfc: N/A PSFStans N/A PSF Fence: WA PSF Railings: N/A PLF/CONCENTRATEb 1 ti ""I'°M IGNC tqv* z"'v'�• SCREWS TO EACH RAFTER. - 8. Were Shear Walls Considered For Structure? -Eyes _Not Applicable Explain Why Not: {iJ doi?afPtttt ROOF PANEL CONNECTION POST TO TRUSS . 9.I5AContinuous Load Path Provide d?�yX Yes —Not Applicable Explain Why Not; - / CONNECTION , . rLyj (,,, VERTICAL SHEATHING OPTION j SC'UPE nN WORK ' 10. Design Soil Bearing Prgswre: 25W PSF Soil Tes[RePorts Submitted?_Ye5 � - ° DESIGN PROFESSIONAL CERTIFICATION STATE IMENT: VE i I certify that, to the best of my knowledge and belief, the attached plans& specifications have been designed to •` - r - AS BUILT CARPORT CONSTRUCTED PER PLAN sr! t f comply with the applicable structural portions, of the building codes currently adopted and enforced by St. Lucia •'"s�a'W� 4.✓ iCounty.I also certify that structural elementsldepicted on these plans provide adequate resistance tothe design�,p" 16 GA'.forces specified: - ` s/f.• HANNEL�BRACE, MIN. NOTE: ALL CONSTRUCTION MUST COMPLY WITH TIIE FBC 2020, AND THE FRC 2020 Paul Welch P.E, 29946 / 5115 . - - �"- UP TO 7' POST. MIN PrintName Cert#&Co.CertAuth. --"'"� OVER 7 POST. MIN. RESIDENTIAL (71T1 EDITION), 2020 PLUMBING CODE, 2020 MECHANICAL CODE AND THE NEC TO -MAX. 60' FROW - - (NFPA 70) 2017 EDITION. Paul Welch Inc. - Z:' (EXCLUDEON PLAN 12/2/2021WALLS). SECURED Signature, Date, and Seal ' 1984 S.W. Biltmore St.Suite#114 Port St. Lucie, FL : r V�-It'�'tY �tJl") _ (4)#12-14,J"]yOTE.S1 Company Name & Address -DRILLING SCREWS." TS NIPPLE. NIPPLE SECURED TO WALL POST WITH (4)#12-14xi" SELF -DRILLING -THE CONTRACTOR, SUBCONTRACTOR, SUPPLIER, ECT. SHALL VERIFY ALL SCREWS DIMENSIONS, BOX EAVE RAFTER TO CONDITIONS AT JOB SITE, PLANS, SPECIFICATIONS, ECT. POST CONNECTION DETAIL -STRUCTURAL FEATURE:> NOT DETAILED ON THESE PLANS WILL BE — ADDRESSED BY THE ENGINEER AS CONSTRUCTION PROGRESSES. -ALL WRITTEN DIMENSIONS ON THESE DRAWINGS TAKE PRECEDENCE OVER SCALED DIMENSIONS. -ALL CONSTRUCTION TO BE IN ACCORDANCE WITH THE FBC / FBCR 2020(7TH EDITION). STRUCTURAL NOTES; 1) DESIGN LOADS IN ACCORDANCE WITH ASCE7-16. - 2) SOIL BEARING CAPACITY: 2000 PS;F (MIN.). WITH A MINIMUM 2500 PSI COMPRESSIVE 3) SLAB / FOOTINGS TO BE CONCRETE STRENGTH AT 28 DAYS. SEE PLAN' FOR SIZES & STEEL REQUIREMENTS. .. _ .. _...,W._. _ _.-. u..,..,.,,".,,,, -"--- _ _ ,.,,„_.,.,•,,.,,,,,,.;- . _ ... __-- _. _ ) STRUCTURAL COMPONENTS TO STALATION OF A SPLITWGOI2CRACKINGOP DUE IN -F/ li 1 .-..-' _.�•. ;-.,, HARDWARE IS NOT PERMITED. . , � 5) UNLESS OTHERWISE NOTED, THE INSTALLATION OF SPECIFIED HARDWARE SHALL _ t ¢,'ZN '�`�. gee) /" "`'y CONFORM TO THE, MANUFACTURES INSTRUCTIONS AND STANDARD PRACTICIES. U_ ggi�p\p Lii Lp. , LL h LL_ N 00 N � to 1 g �lezdx _ r � UJ Q S te i leiy� r t- SHEET NUMBER OF ni n 1 0 Lull PAUT_ WELCH,, P,L FLAIR:CC N0.29945