GENERAL NOTES:
1. CONTRACTOR SHALL VERIFY ALL CONDITIONS AT THE BUILDING AND
NOTIFY THE OWNER OF ANY DISCREPANCIES BEFORE PROCEEDING
WITH ANY WORK.
2. CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR FABRICATION
PROCESSES AND CONSTRUCTION TECHNIQUES (INCLUDING
SCAFFOLDING, BRACING, SHORING, ERECTION, ETC.) FOR
COORDINATION OF VARIOUS TRADES, FOR SAFE CONDITIONS ON THE
JOB SITE, AND FOR COMPLETE COMPLIANCE WITH THE WILLIAM
STEIGER OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 (OSHA).
3. DO NOT SCALE DRAWINGS.
4. CONTRACTOR SHALL THOROUGHLY FAMILIARIZE THEMSELF WITH THE
DRAWINGS WHICH, IN TURN, MAY AFFECT THE COST OF THE PROPER
COMPLETION OF THE WORK HEREIN SPECIFIED, AND CONTRACTOR
SHALL INCLUDE EVERYTHING REQUISITE AND NECESSARY TO THE
ENTIRE FINISHING OF THE WORK, NOT WITHSTANDING THAT EVERY
ITEM NECESSARILY REQUIRED BY SUCH WORK IS NOT SPECIFICALLY
MENTIONED OR SHOWN. CONTRACTOR SHALL FURNISH ALL LABOR
AND MATERIAL NECESSARY FOR THE COMPLETION OF ALL WORK AND
DEMOLITION HEREINAFTER DESCRIBED.
5. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE CODES
AND/OR REGULATIONS OF ST LUCIE COUNTY, STATE OF FLORIDA,
AND ALL OTHER CODES, AND/OR REGULATIONS BY ANY OTHER
AUTHORITIES HAVING JURISDICTION OVER THE WORK.
6. PROTECT EXISTING ADJACENT BUILDING STRUCTURES, FLOOR DECK
AND GROUNDS FROM ANY DAMAGE WHICH MAY OCCUR DURING
PERFORMANCE OF ALL WORK. ANY DAMAGE TO EXISTING FACILITIES
TO REMAIN WILL BE REPAIRED, REPLACED OR RESTORED TO THE
ORIGINAL CONDITION AND TO SATISFACTION OF ENGINEER AT THE
CONTRACTOR'S EXPENSE.
7. CONTRACTOR SHALL MAKE NO CHANGES WITHOUT WRITTEN
APPROVAL FROM THE ENGINEER
8. GENERAL CONTRACTOR SHALL COORDINATE AND OBTAIN ALL
PERMITS REQUIRED TO COMPLETE THE CONSTRUCTION OF THE WORK
AS INDICATED ON THE DRAWINGS.
9. GENERAL CONTRACTOR SHALL INCLUDE IN THE BASE BID ALL FEES
ASSOCIATED WITH THE CONSTRUCTION OF THIS PROJECT, INCLUDING
BUT NOT LIMITED TO PERMIT FEES, DUMP FEES, SUB —CONTRACTOR
PERMIT FEES, DEMO AND IMPACT FEES.
10. CONTRACTOR IS TO COORDINATE AND ORGANIZE THE CONSTRUCTION
PROCESS AND COMPLETE SAME IN A MANNER WHICH LEAST IMPACTS
THE ADJOINING COMMON AREAS, IN ORDER TO MINIMIZE
INCONVENIENCE TO THE OWNER.
11. ALL NEW CONSTRUCTION MUST MEET FLORIDA ACCESSIBILITY CODE
FOR BUILDING REQUIREMENTS LATEST EDITION, AND A.D.A. BARRIER
FREE REQUIREMENTS.
12. CONTRACTOR SHALL VERIFY FINAL SELECTION OF ALL FINISHES WITH
THE OWNER BEFORE PROCEEDING WITH ANY WORK.
13. DISSIMILAR METALS SEPARATION:
WHEREVER DISSIMILAR METALS CONTACT EACH OTHER, AND ARE
SEPARATED FURTHER ON THE BELOW SCALE THAN BY A SINGLE
INTERMEDIATE METAL, THE CONTACTING SURFACES SHALL BE
INSULATED FROM EACH OTHER BY A BITUMINOUS COATING, 15#
ASPHALT SATURATED FELT OR OTHER ENGINEER APPROVED
MEANS METALS ARRANGED IN ORDER OF GALVANIC ACTIVITY:
ALUMINUM, ZINC, GALVANIZED IRON, TIN ON STEEL, LEAD (HARD),
STAINLESS STEEL, COPPER, MONEL.
14. IF DISSIMILAR METALS ARE TO BE JOINED, ENGINEER APPROVED
INSULATION UNIONS MUST BE APPROVED.
LUMBER & CONSTRUCTION NOTES:
NOTES AND SPECIFICATIONS:
Any or all prints or duplications obtained from these plans are valid only if
signed and sealed by a registered professional engineer representing
Mothers Engineering engineer of record.
All construction shall comply with Local, State, and National Codes.
All manufactured items shall be applied or installed in accordance with
manufacturer's specifications and recommendations. And LISTED NOA'S
LUMBER:
All lumber shall be Southern Yellow Pine or Western Red Cedar surfaced
four sides. Southern Yellow Pine shall be treated with chromated
copper arsenate (CCA) 0.40 LBS/CF of retention.
Stringers, cross members, rails, wood post, nailers, and blocking shall be NO.2
or better in accordance with southern pine inspection bureau grading rules.
All sizes as shown on plans.
HARDWARE:
All hardware shall be new stainless 316 grade steel,
for all bolts AND ANCHOR CLIPS S.S. typical.
1. ALL CONCRETE WORK SHALL CONFORM TO THE BUILDING CODE REQUIREMENTS
FOR REINFORCED CONCRETE (ACI 318-19 PLUS UPDATES) & SPECIFICATIONS
FOR STRUCTURAL CONCRETE FOR BUILDINGS (ACI 301-16 PLUS UPDATES)
OF THE AMERICAN CONCRETE INSTITUTE.
2, FABRICATED IN ACCORDANCE WITH THE A.C.I. BUILDING CODE
(LATEST EDITION) AND THE LATEST MANUAL OF STANDARD PRACTICE (A.C.I.
315). SHOP DRAWINGS OF ALL REINFORCING STEEL MUST BE APPROVED BY
THE ENGINEER BEFORE FABRICATION.
3. CONCRETE SHALL BE A MIX DESIGNED TO SECURE A STRENGTH OF MIN
4000 PSI AT 28 DAYS FOR THE NEW WALL AND
SLUMP SHALL BE A MINIMUM OF 3" AND A MAXIMUM OF 5".
CONCRETE DURING AND IMMEDIATELY AFTER DEPOSITING, SHALL BE
THOROUGHLY COMPACTED BY MEANS OF MECHANICAL VIBRATION.
4. CONTRACTOR SHALL MAKE NO CHANGES WITHOUT WRITTEN
APPROVAL FROM THE ENGINEER OR OWNER.
PRODUCT APPROVAL DATA:
Product
Model
Manufacturer
Evaluation Agency
Product Approval
FL / NOA
Expiration Date
Number
OVERHEAD GARAGE
Steel Pan Sectional Garage Door
AMERICAN Building
MIAMI—DADE County Approved
NOA No: 20-0901.25
JULY 31, 2025
DOORS
MODEL # 824
Products Company
SWING DOORS
Fiberglass Opaque
Masonite
Florida Product Approval
FL# 8228—R7
December 31, 2022
Outswing Door
International
WINDOWS
HR 7710 A ALUM.
PGT
MIAMI—DADE County Approved
NOA No: 20-0406.04
AUG 23, 2023
HR PW HR OX TT
WINDOWS
PW 7720 A ALUM.
PG
MIAMI—DADE County Approved
NOA No: 20-040.10
FEB 19, 2024
HR PW HR OX ITT
WALL SIDING
Fiber Cement Siding
James Hardee
Buildin ProductInc.
,
MIAMI—DADE County Approved
NOA No: 20-0825-09
AUG 02, 2026
SOFFIT
HARDIE SOFFIT PANEL
James Hardie
Inc.
MIAMI—DADE County Approved
NOA No: 20-0730.06
May 01, 2022
Building Product,
PPG "FIRE PAINT"
20 MIN SOFFIT PAINT
PPG
N/A
N/A
N/A
ICE & WATER SHIELD
POLY GLASS USA INC
POLY GLASS USA INC
Florida Product Approval
FL# 5259-R29
DEC 21, 2022
CEMENT ROOFING TILE
BORAL VILLA 900 TILE
BORAL ROOFING CO.
MIAMI-DADE County Approved
NOA No: 21-0712.03
SEPT 21, 2026
JURISDICTION: St lucie COUNTY, FL
CODE: FLORIDA BUILDING CODE 2020 7th EDITION
PROJECT ADDRESS: 155 PEPPER LANE JENSEN BEACH FL __ PROJECT NAME: __BROWN-ADDITION_-
ENGINEER-MATHERS ENGINEERING CORPORATION_
BUILDING DESIGNED: ENCLOSED_ X __ OPEN_____
WIND SPEED (3 SECOND GUST): 160 MPH_____ 160 D MPH__ X _
ASCE CATEGORY: 2 (SINGLE FAMILY HOUSE)__X__ OTHER -
EXPOSURE: D
IMPORTANCE FACTOR: _ 1_O _
INTERNAL PRESSURE COEFFICIENT: t0_18
MEAN BUILDING HEIGHT_20.5
OVERHANG_ NIA___ ROOF PITCH-f 2_______
COMPONENTS & CLADDING WIND PRESSURES__I/A_-____
SHUTTERS: YES_o� _ NO__N/A
IMPACT RESISTANT ASSEMBLY: YES_ -%-// NO - - _ -
NOTE:
Contractor is responsible for bracing of structure during
ALL PHASES OF Construction.
All measurements ARE to be verified by contractor prior to start
of job.
All NEW hardware to be Stainless Steel 316 GRADE ONLY
NOTES:
A. THE PROPOSED RENOVATIONS DO NOT STRUCTURALLY ALTER THE REMAINING EXISTING STRUCTURAL SYSTEMS AND A REQUIREMENT TO
UPGRADE IT BY THIS PERMIT APPLICATION IS NOT WARRANTED.
B. EXISTING BUILDING COMPONENTS AND ELEMENTS OUTSIDE THE REMOVATION AREA WILL NOT HAVE THEIR CURRENT WINDLOAD RESISTANT
CAPACITY COMPROMISED BY THE PROPOSED NEW CONSTRUCTION
C. APPROVAL OF THESE PLANS IN NO WAY RELIEVES THE CONTRACTOR OR BUILDER OF COMPLYING WITH ORDINANCES OF LOCAL, STATE, OR
FEDERAL JURISDICTIONS.
D. 2020 FLORIDA BUILDING CODE, 7TH EDITION CHAPTER (1) SECTION 104.11 ALTERNATIVE MATERIALS, DESIGN AND METHODS OF
CONSTRUCTION AND EQUIPMENT. AND RESIDENTAL CHAPTER 3, SECTIONS R301.1.3 ENGINEERED DESIGN.
E. CONTRACTOR TO LOCATE SEAMS FOR BEST USE OF MATERIALS. VERIFY IN FIELD ANY ADDITIONAL BLOCKING OR ADDITIONAL WOOD NEEDED.
FOR THE BEST USE FOR THE PROPOSED NEW CONSTRUCTION
AREA CALCULATIONS
EXISTING LIVING:
UPPER BR & BATH
GARAGE:
COVERED PORCH:
COVERED ENTRY:
TOTAL:
1,840
SF
855
SF (NEW)
300
SF
275
SF
25
SF
3,295 SF
TOTAL A/C 2,970 S.F.
SEE FLOOR PLAN SHEETS
EXISTING RESIDENCE LOCATION OF 2ND STORY
/ ADDITION TO RESIDENCE
INTERIOR REMODEL
LOCATION OF GARAGE
— REMODEL
EXISTING RESIDENCE
144 PEPPER LANE
REE
PI:
PPEF
SITE LOCATION MAP
155 PEPPER LANE JENSEN BEACH FL
NOTE:
THE PROPOSED RENOVATIONS DO NOT STRUCTURALLY ALTER THE
REMAINING EXISTING STRUCTURAL SYSTEMS AND A REQUIREMENT
TO UPGRADE EXISTING WINDOWS BY THIS APPLICATION
IS NOT WARRANTED, FOR THIS PERMIT.
EXISTING BUILDINGS COMPONENTS AND ELEMENTS OUTSIDE THE
RENOVATION AREA WILL NOT HAVE THEIR CURRENT WIND LOAD
RESISTANT CAPACITY COMPROMISED BY THE PROPOSED NEW
CONSTRUCTION.
APPROVAL OF THESE PLANS IN NO WAY RELIEVES THE
CONTRACTOR OR BUILDER OF COMPLYING WITH ORDINANCES
OF LOCAL, ST LUCIE COUNTY STATE OR FEDERAL JURISDICTIONS.
NOTE:
THESE PLANS AND ALL ASSOCIATED DOCUMENTS ARE VALID FOR REPAIR
CONSTRUCTION ONLY UPON STAMPED APPROVAL FROM APPROPRIATE
GOVERNING JURISDICTION. THESE PLANS ARE VOID AND SHALL NOT BE
USED FOR CONSTRUCTION OR ANY OTHER PURPOSE WITHOUT THE
CITY OF STUART BUILDING DEPARTMENT REVIEW AND APPROVAL.
NOTE: ADDITION/ALTERATION
F.B.C. 7th ED. 2020 EXISTING BUILDING (section 602,603,604)
ADDITION: AN EXTENSION OR INCREASE IN FLOOR AREA, NUMBER OF STORIES
OR HEIGHT OF A BUILDING OR STRUCTURE.
ALTERATION: ANY CONSTRUCTION OR RENOVATION TO AN EXISTING
STRUCTURE OTHER THAN REPAIR OR ADDITION. ALTERATIONS ARE CLASSIFIED
AS LEVEL 1, LEVEL 2, LEVEL 3.
THIS PROJECT IS CLASSIFIED AS ADDITION. LEVEL 1
Scale: N.T.S.
DRAWING INDEX
TABLE OF CONTENTS
BUILDING PLANS
CVR
SITE LOCATION GENERAL NOTES NOA'S
S-1
EXISTING 1ST FOUNDATION PLAN
S-2
LOWER FLOOR & 2ND FLOOR PLAN
S-3
EXISTING FLOOR PLAN
S-4
WALL SECTION DETAILS
S-5
NEW / EXISTING ROOF PLAN
S-6
NOTES SPECIFICATIONS
T-1
ROOF PLAN SECTIONS DETAILS
P-1
NEW PLUMBING PLAN, RISER DIAGRAM NOTES
P-2
NEW PLUMBING PLAN, RISER DIAGRAM NOTES
M-1
NEW A/C PLAN, DUCT LAYOUT— DIAGRAM NOTES
E-1
NEW LOWER LEVEL ELCETRICAL PLAN, NOTES
E-2
NEW UPPER LEVEL ELCETRICAL PLAN, NOTES
-6 � 5r
III
Date �Rev=sions
ST LUCIE COUNTY COMMENTS
1 4/16/22
000,
LO (.9
(N
a o
CN w a
N p G
N
z
X
r Q
o
w
=0)
c�
Lie M v0
X
Ld
o � IJw
ro
(14 V) U
W W
Z p p U�
W W U �4
C0 W
O E-4 Q
O
� xz�
E-+
O W
zW w
Z �D
�Cr
ZW
04
W�II W
�-1 W
a
LO
r—I
wkyglgM UI f4 H� S, PE
,•��OEN'S .< i
PE
o'. S A F ��
//y��IT(i�b�NLY
DRAWN
J. V.H.
CHECKED
W.J.M.
DATE
12/21/21
SCALE
AS NOTED
JOB NO.
2021 BROWN
SHEET
CVR —1
• • • Q
Mr Ow
1l!40i*r*±44
(MATCH SLOPE AND EXISTING CONC EDGES
TO EXI TING FLOOR SLAB FLUSH
30 NEW 3000 PSI CONCRETE VERIFY IN FIELD W/ NEW 4" CONC. FILL
FILL SLAB W/ 6 MILL PLASTIC
a
p
z TERMITE TREATED COMPLETELY
3 AROUND *PERIMETER TYP. 5'—O"
j
MATCH SLOPE AND EXISTING EDGES
1�
w
0VERIFY
VERIFY IN FIELD W/ NEW 4" CONC. FILL
EXISTING WALL
N
>
z
w
FAMILY ROOM
o VAULT CEIL
iO
N o N
0
r-
w
>
INSTALL ABU66 BASE
LIVING ROOM W/2 OTY MTS 18 STRAPS
NOTE: LOAD BEARING TO EACH COL SIMPSON
VAULT CEIL INSTALL NEW P.T. 6X6 VERIFY IN FIELD
W/ 5/8" DRYWALL WRAP
INSTALL ABU66 BASE
W/2 QTY MIS 18 STRAPS
TO EACH COL SIMPSON ,
VERIFY IN FIELD
NEW P.T. 6X
STRUCTURA BEAM ABOVE TO REMAIN? VERIFY
P
m
v
NOTE: EXISTING
FOYER SPIRAL STAIR I
j 'VAULT CC14 -- TO REMAIN -
EXISTING DOOR I
TO REMAIN
LAM 12'-4" I II
'^T VERIFY IN FIELD
q� II
12'
O
mrREMOVE WALLS
I
60"
SHOWN DOTTED I
PATCH FLOOR AS REQD:j I
�
BATH `1
I
LIVING ROOM
//—J
I 9'-0" CEIL.
VAULT CEIL ii 1PATCH FLOOR AS REQD.
�Y�
SINK & W.C. LOCATION /
VERIFY FLOOR SLAB
EXISTING GROUND FL A/C III W.C.
>
SYSTEM,TO BE ERMIT II VED��J
RATE
0
A/C PS
VERIFY/CAP ALL EXISTING
Q
DRAIN LINES
cr}
I
i
m
of
w
9' 0" CEIL i
i �\ i i
\ ,
"1
a
i
iI l I
TUB
/
z
OU
��
LL7 �1--
B
W
� �
------
cot-
ZW
I SI K
L---�
NEW 1 HR DOOR HALL X�
BATH
AND FRAME
9'-0" CEIL. r".
III
9'_0" CELL.
c
REMOVE WALLS
SHOWN DOTTED
HR FlRREE
w II
-
I
VERIFY IN FIELD 1
W.C.
C
NEW 1 HOUR
Il—
RATED WALL
REMOVE
4" WALL-�//
i
4" STEP ICE
I i
a
D
0-7
\
6"
1
3'-4"
11'-7"
I
I
VERIFY fN FIELD
INSTALL NEW LAU
DRY
I
I
9
o CEIL
KITCHEN
3' 6"
FIRE RATEDUL 14'-10"
8
VAULTED CEIL.
I >ALL SLAB
NEW GARAGE
REMOVE
VERIFY IN FIELD
4" WALL
I
I
I
0
NEW 3000 PSI CONCRETE
FILL SLAB W/ 6 MILL PLASTIC
— — — — -----
----
z
i
INSTALL NEW 2X6 STUD WALL
W/ P.T. BOTTOM PLATE 0 I
N
I
I
16" O.0 W/ NEW R-16 FILLED O
uj
I
W/ BATT INSULATION 04
UL RATED 1 HR WALL
w
BK NO
K
1 CAR GARAGE
9'-0" CE
9'-0" VERIFY CELL.
1
I
NEW 3000 PSI CONCRETE
I
I
FILL SLAB W/ 6 MILL PLASTIC
cal
TERMITE TREATED AROUND
I
AROUND ® PERIMETER TYP.
MATCH SLOPE ANY, EXISTING EDGES
VERIFY IN FIELD 4' +-NEW CONC. FILL
TO noun
OWNG
MATCH SLOPE & EXISTING CONC EDGES
Mn..DGGn
?
TO EXISTING FLOOR SLAB TYP
NEW 170 D ZONE GARAGE DOOR
NOTE: EXISTING O
MTL. DOOR & WINDOW NEW OPENING
TO REMAIN -VERIFY 12'-0"
INSTALL NEW 8" BLOCK WALL
20'-0"
FILLED CELLS 4000 PSI GROUT
# 5 BAR EACH CELL VERIFY
W/ NEW R 11, FOIL INSULATION
MATCH STUCCO TO EXIST WALL
FOUNDATION
30'-0" EXISTING
VERIFY CONC DRIVE
TO REMAIN
8" CONIC COL TO REMAIN
EXISTING 8" HEADER BEAM
W/ ROUGH STUCCO FINISH
MATCH STUCCO AT FIRST FLOOR
AFTER WINDOWS ARE INSTALLED
EXISTING 8" BLOCK WALL
W STUCCO FINISH
N WORK FIRST FLOOR
NOTE: LOAD BEARING
INSTALL NEW P.T. 6X6
W/ 5/8' DRYWALL WRAP
INSTALL ABU66 BASE
W/2 QTY MIS 18 STRAPS
TO EACH COL SIMPSON
VERIFY IN FIELD
VERIFY ELEVATOR LOCATION AND
FILL W/ NEW 4000 PSI CONCRETE
TYP. SLAB W1 6 MILL PLASTIC
TERMITE TREATED AROUND
AT EXISTING ® PERIMETER TYP.
MATCH SLOPE AND EXISTING EDGES
VERIFY IN FIELD 4'+-NEW CONC. FILL
RELOCATE EXISTING PLUMBING
DRAIN LINE, PATCH FLOOR AS READ.
VERIFY IN FIELD
NOTE: NEW WD-9500 ELEVATOR INSTALL
18" DEEP BASE FOR ELEVATOR VIE
PAD LOCATON' & PLAN DETAI
SEE ELEVATOR SHOP DRAWINGS
FOR TYPE, ELECTRICAL CONNECTIONS, MODEL
SPECIFICATIONS- ALL UNDER SEPARATE STATE
FLA PERMIT -VERIFY IN FIELD TYP.
VERIFY SINKS TO BE REMOVED
CAP ALL PIPES, DRAIN LINES
VERIFY IN FIELD ALL CONDTIONS
VERIFY SHOWER LOCATION FILL SLAB
W/ NEW 3000 PSI CONCRETE
FILL SLAB W/ 6 MILL PLASTIC
TERMITE TREATED AROUND
AROUND 0 PERIMETER TYP.
MATCH SLOPE AND EXISTING EDGES
VERIFY IN FIELD W/ NEW 4" CONC. FILL
O
VERIFY TUB LOCATION FILL SLAB
RELOCATE EXISTING PLUMBING
DRAIN LINE, PATCH FLOOR AS READ.
VERIFY IN FIELD
VERIFY SINKS, W.C. TO BE REMOVED
CAP ALL PIPES, DRAIN LINES
VERIFY IN FIELD ALL CONDTIONS
FOR NEW FIXTURES
INSTALL NEW 2X6 STUD WALL
W/ P.T. BOTTOM PLATE
16" O.0 W/ NEW R-16 FILLED
W/ BATT INSULATION
UL RATED 1 HR WALL
w
0
m
Q
i0 O
N U-
o>
z
O
0
w
to
INSTALL NEW ELEC TANKLESS
ON DEMAND ELEC W.H. SEE P-1
REMOVE EXISTING HWH
VERIFY IN FIELD CAP ALL PIPES
SEE SHEET P-1
FUTURE WASHER DRY LOCATION
VERIFY IN FIELD WALL CONDTIONS
MODIFY AS REQUIRED
LOWER LEVEL FLOOR PLAN _
SCALE: 1 /4" = 1'--0"
BUILDING NOTES:
THE STRUCTURE IS DESIGNED TO BE SELF-SUPPORTING AND STABLE AFTER THE BUILDING
IS FULLY COMPLETED. IT IS SOLELY THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE
ERECTION PROCEDURE AND SEQUENCE AND TO INSURE THE SAFETY OF THE BUILDING
AND ITS COMPONENT PARTS DURING ERECTION. THIS INCLUDES THE ADDITION OF
WHATEVER SHORING, SHEETING, TEMPORARY BRACING, GUYS OR TIEDOWNS WHICH MIGHT
BE NECESSARY. SUCH MATERIAL SHALL REMAIN THE CONTRACTOR'S PROPERTY AFTER
IT IS SOLELY THE CONTRACTOR'S RESPONSIBILITY TO FOLLOW ALL OSHA APPLICABLE
SAFETY CODES AND REGULATIONS DURING ALL PHASES OF CONSTRUCTION.
MECHANICAL FRAMING LOADS, OPENINGS AND STRUCTURE IN ANY WAY RELATED TO
THE MECHANICAL REQUIREMENTS ARE SHOWN FOR BIDDING PURPOSES ONLY.
CONTRACTOR TO VERIFY THAT ELECTRICAL, PLUMBING OR OTHER EXISTING ELECTRICAL
PIPING OR NEW PIPING, DUCTWORK DOES NOT CONFLICT WITH PROPOSED TRUSS LOCATIONS
CONCRETE NOTES:
ALL REINFORCING STEEL SHALL BE ASTM A615 GRADE 60.
C.I.P. CONCRETE CONSTRUCTION OR CONTROL JOINTS IN SLAB ON GRADE TO BE AS SHOWN ON
PLANS. WHERE NOT SHOWN, LIMIT CONTROL JOINT SPACING TO NO GREATER THAN 15 FEET ON
ANY SIDE FOR 5 INCH SLABS AND 12 FEET FOR 4 INCH SLABS ON GRADE. THE SECTIONS
BOUNDED BY CONTROL OR CONSTRUCTION JOINTS SHALL BE APPROXIMATELY SQUARE, WITH THE
LENGTH TO WIDTH RATIO LESS THAN 1.5.
COORDINATE CONCRETE WORK WITH ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR
ARCHITECTURAL FINISHED CONCRETE, RECESSED AREAS, EMBEDDED ITEMS, AND SPECIAL CONTROL
JOINTS.
PROVIDE DOWELS IN FOOTINGS TO MATCH VERTICAL WALL AND PIER REINFORCING. PROVIDE
CORNER BARS AT WALL AND FOOTING CORNERS TO MATCH HORIZONTAL REINFORCING. SEE BAR
SPLICE TABLE BELOW FOR MINIMUM LENGTH OF EACH LEG.
UNLESS OTHERWISE NOTED OR DETAILED, ALL REINFORCING BAR SPLICES SHALL BE IN
ACCORDANCE WITH THE TABLE SHOWN BELOW:
CONCRETE SPLICES TYPE A TYPE B
BAR (NON TOP BAR) (TOP BAR)
SIZE LENGTH (IN) LENGTH (IN)
#3 14 18
#4 19 24
#5 23 30
#6 30 40
#7 41 54
#8 55 71
#9 69 90
#10 88 114
#11 108 140
TOP BARS ARE HORIZONTAL REINFORCEMENT SO PLACED THAT MORE THAN 12 IN. OF FRESH
CONCRETE IS CAST IN THE MEMBER BELOW THE REINFORCEMENT.
PROVIDE THE FOLLOWING MINIMUM CLEAR COVER FOR REINFORCING STEEL FROM SURFACE OF
CONCRETE:
• FOR CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH:
3" IN GENERAL
2" FOR FOUR INCH SLABS ON GRADE
• FOR CONCRETE SURFACE EXPOSED TO THE WEATHER OR AGAINST WHICH BACKFILL WILL BE PLACED:
2" FOR #6 BARS AND LARGER
1-1/2" FOR #5 BARS AND SMALLER EXCEPT AS NOTED FOR PRECAST PANELS.
• FOR SURFACES OTHER THAN ABOVE:
1-1/2" FOR COLUMN SPIRALS OR TIES, OR STIRRUPS (EXCEPT PAN JOISTS)
3/4" FOR SLABS AND FOR STIRRUPS IN PAN JOISTS
TOLERANCES FOR BAR COVER ARE t 3/8 INCH FOR CONCRETE HAVING A THICKNESS OF 8
INCHES OR LESS AND t 1/2 INCH FOR CONCRETE HAVING A THICKNESS GREATER THAN 8
INCHES. TOLERANCE FOR LONGITUDINAL LOCATION OF BENDS AND ENDS OF REINFORCEMENT SHALL
BE t 2 INCHES EXCEPT AT DISCONTINUOUS ENDS OF MEMBERS WHERE THE TOLERANCE SHALL BE
t 1/2 INCH. TOLERANCE FOR BAR SPACING IS t 2 INCHES. TOLERANCE FOR LENGTH OF LAP
SPLICE IS+-1 INCH, AND TOLERANCE FOR EMBEDDED LENGTH IS f 1 INCH.
NOTE: MATERIAL DIMENSION
MATERIAL DIMENSIONS ON PLAN REFLECT
NOMINAL DIMENSIONS IE: 5/8" PLYWOOD IS
19/32", 2X12 IS 11"X11j", 8" BLOCK IS 7j".
AREA CALCULATIONS
EXISTING LIVING: 1,840
UPPER BR & BATH 855
GARAGE: 300
COVERED PORCH: 275
COVERED ENTRY: 25
SF
SF (NEW)
SF
SF
SF
TOTAL: 3,295
SF
TOTAL A/C
2,970
S.F.
WALL LEGEND
EXISTING 8" WALL 8"
TO REMAIN
NO WORK
NEW 6" U.L WALL 6"
1 HOUR U.L RATED
NEW 8" BLOCK WALL W/ 8" CELL
FILLED CELL 4000 PSI
# 5 BAR EACH CELL
NEW 6" R-16 WALL ® 6" NEW
2X6 WALL 12" O.C.
NEW 4" WALL 4" NEW
W/ 5/8" DRYWALL
EXISTING 4" WALL TO C_-----4" REMOVE
BE REMOVED --- — —
NOTE: NON LOAD BEARING
VERIFY IN FIELD
NOTE: LOAD BEARING
NEW 6' X6' P.T.COL
W 5//8' DRYWALL WRAP
V�RIFY IN FIELD
NEW 6" OR 4" WALL
W/ 5/8" DRYWALL
WOOD POCKET DOOR 2'-8" POCKET
EXISTING 8" CMU EXISTING CELL m 8" CELL EXISTING
NEW 4000 PSI CONCRETE
FILL SLAB 6 MILL PLASTIC LL�I�J
TERMITE TREATED
TED AROUND
COMPACTED ® PERIMETER
-" -TYP. VERIFY IN FIELD - -
EXISTING GROUND FL. A/C I�
SYSTEM TO BE REMOVED IA?K I
NO WORK THIS PERMIT—�
SEE ELEVATOR SHOP DRAWINGS
FOR TYPE, ELECTRICAL CONNECTIONS, MODEL
AND SPECIFICATIONS- ALL UNDER SEPARATE
FLA STATE PERMIT -VERIFY IN FIELD TYP.
NEW 4000 PSI CONCRETE 48X60
FILL SLAB W/ 6 MILL PLASTIC
NEW ELEV
CONCRETE NOTES
ALL CONCRETE WORK SHALL CONFORM TO THE BUILDING CODE REQUIREMENTS
FOR REINFORCED CONCRETE (ACI 318-19 PLUS UPDATES) SPECIFICATIONS FOR
STRUCTURAL CONCRETE FOR BUILDINGS (ACI 301-16 PLUS UPDATES) OF THE
AMERICAN CONCRETE INSTITUTE.
FABRICATED IN ACCORDANCE WITH THE A.C.I. BUILDING CODE
(LATEST EDITION) AND THE LATEST MANUAL OF STANDARD PRACTICE (A.C.I.
315). SHOP DRAWINGS OF ALL REINFORCING STEEL MUST BE APPROVED BY THE
ENGINEER BEFORE FABRICATION.
CONCRETE SHALL BE A MIX DESIGNED TO SECURE A STRENGTH OF MIN
4000 PSI (UNLESS OTHERWISE SPECIFIED) AT 28 DAYS FOR THE SLAB AND
FOOTINGS SLUMP SHALL BE A MINIMUM OF 3" AND A MAXIMUM OF 5".
CONCRETE DURING AND IMMEDIATELY AFTER DEPOSITING, SHALL BE
THOROUGHLY COMPACTED BY MEANS OF MECHANICAL VIBRATION.
NOTE:
THE PROPOSED RENOVATIONS DO NOT STRUCTURALLY ALTER THE
REMAINING EXISTING STRUCTURAL SYSTEMS AND A REQUIREMENT
TO UPGRADE EXISTING WINDOWS BY THIS APPLICATION
IS NOT WARRANTED, FOR THIS PERMIT.
EXISTING BUILDINGS COMPONENTS AND ELEMENTS OUTSIDE THE
RENOVATION AIREA WILL NOT HAVE THEIR CURRENT WIND LOAD
RESISTANT CAPACITY COMPROMISED BY THE PROPOSED NEW
CONSTRUCTION,
APPROVAL OF THESE PLANS IN NO WAY RELIEVES THE
CONTRACTOR OR BUILDER OF COMPLYING WITH ORDINANCES
OF LOCAL, COUNTY STATE OR FEDERAL JURISDICTIONS.
NOTE:
THESE PLANS AND ALL ASSOCIATED DOCUMENTS ARE VALID FOR
CONSTRUCTION ONLY UPON STAMPED APPROVAL FROM APPROPRIATE
GOVERNING JURISDIC-nON. THESE PLANS ARE VOID AND SHALL NOT BE
USED FOR CONSTRU(;TION OR ANY OTHER PURPOSE WITHOUT THE
BUILDING DEPARTMENT REVIEW AND APPROVAL.
w
a
cLL
o�
xa
3n
of
o�
a�
w�
oz'
c4
HJ
r
wz
mw
0
z�
�z
a-
x�
�a
co
zw
aQ
ww
x�
�w
m N
oLoo z
0
OI o a
o
w a 00 w °
a a ( G
z c"I
<w I,0 ID
u
oz n
Tz O
m Z \J
O a OL LS
a � o_
zo
Ll
F
w r<
�0 3 a
00 =�
O nnn
J o 2
o W M V
oa X J 0
u-
a<
w NI.
0_
a
o f to J
a (N(n U
z-
�o
�o
a=
UZ
zw
oa
o z,
a
xw
L;
a ¢.
uw
N �
Y z
w ~
z
�tt Zaw NN
W W E4 7
�= H
s Z
6
w�
O
j H
oas O a
wzo
_? m w
~ F+� Z v o
zac
z
E"1 � a p
y
C C3
f•�l
z asaw
U~w
c
lid
w Lo
O
�aa
oa r� f"1
oa
wvoz
a
ox
>zx
az
iw to v,
owe
s�
w
wm
aza
a
<�zw
�r
azz
w r WILLIAM J. MATHERS, PE
� � a
w a # 1>59 /;
,
c � a C58
";4a "�, ATE OF
P G:,
STFfG 1(
0z� I
w�
v, U
�w
�a
;ww
w Ll
o_�
Gov,
Wzo
2os
�o
U(n r
rr a: w
DRAWN
J.V.H.
CHECKED
W.J.M.
DATE
10/21/21
SCALE
AS NOTED
JOB NO.
2021- BROWN
SHEET
S-1
3
I
KN
NEW 4" 3000 PSI CONCRETE
FILL SLAB W/ 6 MILL PLASTIC
TERMITE TREATED AROUND
0 PERIMETER TYP.
VERIFY IN FIELD
A/C
A/C
Y
3
z
O
z
w
>
O
m
Q
O Lr
0=
O
OJ r
3
M
O
Z
z
O
U
O
Z
Lu
(n
X
W
8"
O
30'-0"
8" COL TO REMAIN O4 EXISTING 8" COL TO REMAIN
18'�
VERIFY STRUCTURAL BEA A13OVE TO REMAIN VERIFY
ENCLOSED PORCH
9'-4" CEIL
VERIFY EXISTING OPENING
NOTE:EXISTING WINDOW
AND FRAME TO REMAIN
VERIFY IN FIELD
—o
iV
o
Z
n
W
VERIFY A/C LOCATION
NEW UNITS BY OTHERS
NOT PART OF THIS PERMIT
OR SCOPE OF WORK
3'-0"
28'-8" �d
VERIFY INSIDE DIM.
LIVING ROOM
VAULT CEIL.
REMOVE WALLS
SHOWN DOTTED
PATCH FLOOR AS
O
VERIFY
REMOVE WALLS
SHOWN DOTTED
PATCH FLOOR AS REOD
II
I
I�
EXISTING 4" WALLS TO
II BE REMOVED TYP.
I• I I NOTE: NON LOAD BEARING
VERIFY IN FIELD
ABU66 1 SIMPSION ABU66
T. 6X6 1 W/ NEW P.T. 6X6
FOYER AENG NOTE:
VATO
O1 VAULT CEIL. UND P SIT ATE
EXISTING DOOR TO REMAIN 12
m� 12'-4"VERIFY STAIRO �2 VIF V
REMOVE WALSHOWN DOTTED
PATCH FLOOR AS READ.
VERIFY FOR NEW WALL o zalti.
SINK `!/
BATH
EXISTING GROUND FLOOR A/C 9'-O" CEIL.
SYSTEM TO BE REMOVED I SINK
FLOOR S ABN
IN ITS ENTIRETY
SYSTEM TO BE REMOVED
NO WORK THIS PERMIT I I W C
VERIFY IN FIELD I FILL IN SHOWER W/
-7� NEW 3000 PSI CONC
//" --- --I REMOVE
ALILSTYP.PANTRY
WALLS
55' NEW WALL M III I / /
VERIFY. 3'-6" / \ I CL / 66
VERIFY. (--� I 9'-0" CEIL
U i i ( TUB �.
o I L� OG1-- ---- \=-__
p zw I Sltil(
KITCHEN CABINET HUTCH FY L___.
z BowL SEE SHOD DWG HALL X° BATH
SINK 9'-O" CEIL. wa11
SINK
013'
V- 4" ZCABISEE E704 HUTCH
DWG
— — — — — — — — — — — — — — — -
Y
0
Z
3
3
IC NEW OM
O
to BAINET / HUTCH
Z
w SEE SHOP DWG -�
of
W BK NOOK
>
9'-0" CEIL.
x
W
NOTE: SEE SHEET S-3
NEW GARAGE DOOR DETAILS
G%
F"
ON
•� t
INSTALL NEW 2X6 STUD WALL
P.T. BOTTOM PLATE
16" O.0 W/ NEW R-16 FILLED
b
cc
W/ BATT INSULATION N
U RATED 493 1 HR WALL
1 CAR GARAGE
9'-0" VERIFY CEIL.
�NSH4 HUTCH
UK
visnNA
MR.000R I
K1
.,
30'-0"
NEW 170 D ZONE GARAGE DOOR
ONEW MASONARY OPENING
12'-0"
20'-0"
LOWER LEVEL FLOOR PLAN
a
NOTE:VERIFY ELEVATOR LOCATION
VERIFY ELEVATOR SEPRATE PERMIT)
VERIFY PIT LOCATI N 18" THEN FILL W/
NEW 4000 PSI CONCRETE SLAB W/ 6 MILL
PLASTIC,TERMITE TREATE AROUND
THE PERIMETER AS REQUIRED TYP.
MATCH SLOPE AND EXISTING EDGES
VERIFY IN FIELD 4' +- NEW CONC. FILL
NOTE:
SEE SHOP DWG, PLAN FOR ELEVATOR
P
SEE ELEVATOR SHOP DRAWINGS
LOCATION & PLAN DETAILS
FOR TYPE, ELECTRICAL CONNECTIONS, MODEL
SPECIFICATIONS- ALL UNDER SEPARATE STATE
FLA PERMIT -VERIFY IN FIELD TYP.
NOT PART OF THIS PERMIT
OR SCOPE OF WORK
NOTE: VERIFY WET LOCATIONS
VERIFY EXISTING FLOOR SLAB
OLD SHOWER & TUB LOCATION
VERIFY FLOOR SLAB, CAP OLD
PLUMBING & DRAIN LINES
VERIFY IN FIELD
EXISTING GL. BLOCK PANEL
�— 48" WINDOW TO REMAIN
VERIFY IN FIELD
8" EXISTING WALL
VERIFY IN FIELD
SEE PLUMBING PLAN FOR
FIXTURES TO REMAIN / MODIFIED
VERIFY IN FIELD FOR NEW USE
NEW TILE OVER EXISTING
CONCRETE TO REMAIN
EXISTING GL. BLOCK PANEL
WINDOWS TO REMAIN
VERIFY IN FIELD
SEE PLUMBING PLAN FIXTURES
TO REMAIN / MODIFIED
VERIFY IN FIELD
FOR NEW USE LOCATIONS
�— EXISTING 200 AMP PANEL
TO REMAIN ( MODIFIED
VERIFY IN FIELD
ALL NEW ELECTRICAL WORK
UNDER SEPARATE PERMIT
/11'-WINDOWS
EXISTING GLASS BLOCK PANEL
TO REMAIN
VERIFY IN FIELD
>
O
m
Q
(0 O
I O
CV Lei, r-`
w
o>
Z
O
U
W
In
WALL LEGEND
EXISTING 8" WALL
TO REMAIN
NO WORK
NEW 6" R-16 WALL 6"
1 HOUR U.L RATED
NEW 8" BLOCK WALL W/ 8" CELL
FILLED CELL 4000 PSI
# 5 BAR EACH CELL
NEW 6" R-16 WALL ® 6" NEW
2X6 WALL 12" O.C.
NEW 4" WALL 4" NEW
W/ 5/8" DRYWALL
EXISTING 4" WALL TO 4" REMOVE
BE REMOVED
NOTE: NON LOAD BEARING
VERIFY IN FIELD
NOTE: LOAD BEARING
NEW 6" X6' P.T. COL
VW 5//8" DRYWALL WRAP
RIFY IN FIELD
NEW 6" OR 4" WALL
W/ 5/8" DRYWALL
WOOD POCKET DOOR 2'-8" POCKET
EXISTING 8" CMU FILLED CELL m 8" CELL EXISTING
NEW 3000 PSI CONCRETE
FILL SLAB W/ 6 MILL PLASTIC
TERMITE TREATED AROUND
® PERIMETER TYP.
VERIFY IN FIELD
EXISTING GROUND FL. A/C
SYSTEM TO BE REMOVED IA?5K
NO WORK THIS PERMIT—�
SEE ELEVATOR SHOP DRAWINGS
FOR TYPE, ELECTRICAL CONNECTIONS, MODEL
AND SPECIFICATIONS- ALL UNDER SEPARATE
FLA STATE PERMIT -VERIFY IN FIELD TYP.
NEW 4000 PSI CONCRETE 48X60
FILL SLAB W/ 6 MILL PLASTIC
NEW ELEV
NOTE: MATERIAL DIMENSION
MATERIAL DIMENSIONS ON PLAN REFLECT
NOMINAL DIMENSIONS IE: 5/8" PLYWOOD IS
19/32", 2X12 IS 1> 'X11 j", 8 BLOCK IS 7j".
NEW 8" COL ON TOP OF BEAM
VERIFY IN FIELD
L
14'-7"
VERIFY OPENING
I
00 —
N r CUSTON SHELF SYSTEM
I M CLOSET
8'-4" CEIL.
NOTE: ADDITIONALTERATION
F.B.C. 7th ED. 2020 EXISTING BUILDING (section 602,603,604)
ADDITION: AN EXTENSION OR INCREASE IN FLOOR AREA, NUMBER OF STORIES
OR HEIGHT OF A BUILDING OR STRUCTURE.
ALTERATION: ANY CONSTRUCTION OR RENOVATION TO AN EXISTING
STRUCTURE OTHER THAN REPAIR OR ADDITION. ALTERATIONS ARE CLASSIFIED
AS LEVEL 1, LEVEL 2, LEVEL 3.
THIS PROJECT IS CLASSIFIED AS ADDITION. LEVEL 1
AREA CALCULATIONS
EXISTING LIVING: 1,840
UPPER BR & BATH 855
GARAGE: 300
COVERED PORCH: 275
COVERED ENTRY: 25
SF
SF (NEW)
SF
SF
SF
TOTAL: 3,295
SF
TOTAL A/C
2,970
S.F.
SCALE: 1/4" = V-0"
L- -- — — — — — — — — — — — — —
(- CUSTON SHELF SYSTEM CLOSET
(
SM.CLOSET
8'-4" CEIL.
L----------------
OPEN
OVAULTED CEIL.
3
O
z
U'
z
U
w
30'-0"
O VERIFY IN COL
FIELD TOP OF BEAM
,L BEAM BELOW TO REMAIN
O
z
Z
MASTER SUITE 3
9'-4" CEIL. w
M r.�) w
—� LINE OF PORCH WALL DOTTED BELOW
9,^D„
4'-8"
MIN OPENING
I
SINK
10 L HALL
VAULT CEIL
i�
� A
VAULT CEIL.
36" S.C. w
0
-- - o 3'-5"
r
I
n
NEW OPENING n
_ VERIFY IN FIELD
36" S.C.
3'-9"
VERIFY MIN.
SPIRAL STAIR
TO REMAIN 4X4 POST
EXISTING
F
2668 W001
22"x36"
I EXIST DOO
ATnc
CCESS
3
BEDROOM
2
Q 8'-0"
CEIL.
w
z <V
4
w
J
z
V
3
z
w
>
o
F-
N
EGRESS WINDOW
EXISTING
1
EXISTING 36" RAILING
TO REMAIN
VERIFY IN FIELD
30'-0"
13'-3"
VERIFY IN FIELD
OPENING
LOFT SPACE
8'-4" CEIL.
NOTE: REMOVE OLD CLOS T WALLS
INSTALL 2X4 WALL W/ 5%FS" DRYWALL
6'-8"
VERIFY IN FIELD
2'-0)
N CLOSEI
N
NOTE: INSTALL NEW 2X4 STUD
WALLS W/ 5E8' DRYWALL
VERIFY IN FI LD
BEDROOM 3
8'-0" CEIL
W
VERIFY IN FIELD
14"
EGRESS WINDOW
EXISTING
UPPER LEVEL FLOOR PLAN
0
NEW 8" COL ON, TOP OF BEAM "-
VERIFY IN FIELD 0,
00
I
sN
wd
¢3
zr (�
a i U7Cq
D T
,f o 8 OO
s< I o
OD
oa 00 w NEW TILE OVER NEW �0 N 0
PT 5/8 PYL-WD DECK ?z N
z 0
Fw O
Z �J
o O
U
o
a 4 En
" Mpp
a �
00 0 m V °o S 0)
n�
w M V
o� Ei J 0
w p I.L.
Iz
a w U)H it
In � Q -+
z N 1n V
ELEVATOR NOTE: o
SEE LOWER LEVEL PLAN FOR ELEVATOR
PAD LOCATION & PLAN DETAILS I zo
SEE ELEVATOR SHOP DRAWINGS
FOR TYPE, ELECTRICAL CONNECTIONS, MODEL O1
SPECIFICATIONS- ALL UNDER SEPARATE STATEa s
FLA PERMIT -VERIFY IN FIELD TYP.
NOTE: F
SEE LOWER LEVEL PLAN FOR ELEVATOR a
LOCATION
rw
ow w�
V
a
mR
o>
0
�a Qza
a vW1
z a �W'1 Z H o ►-� cx-y o4 wN �/
W
g N H
O w O V
�o
o Z
s 04
�zLL
O rr��
N LL ~ V1 og
Wiz
EXISTING OLD CLO F"T WALLS
SKIM WALL W, 5DRYWALL
�aE-4
�
ono
o
=x
>
aa
row
Wzz�
�as
z
�ac
a
NN
Q� o
>
F+�
wza
Lo
�aa
LO
Tn
V 1
ooa
a o �
z
R O U
o�w
rya
u
W�L
<_ a
�a
x
JUI
m
W z z
WILLIAM J. MATHERS, PE
R
FL # 19658 "„
o= U
W i U
�zz
0
zr'
a '
Y _
lea
=Q
EOF
moo
o
,
qL <�
0
R I
�tio
f/r,
o
STRUCTORE.PNLY'`
�z-
Nwz
�w
amx
4z�
" o
oFw
SCALE: 1/4" = 1'—O" M
ems-
37
oCNx
_�
zzo
w�W
NOTE:
THESE PLANS AND ALL ASSOCIATED DOCUMENTS ARE VALID FOR
CONSTRUCTION ONLY UPON STAMPED APPROVAL FROM APPROPRIATE
GOVERNING JURISDICTION. THESE PLANS ARE VOID AND SHALL NOT BE
USED FOR CONSTRUCTION OFF ANY OTHER PURPOSE WITHOUT THE
BUILDING DEPARTMENT REVIEW AND APPROVAL.
WN
.V.H.
CHECKED
W.J.M.
DATE
10/21 /21
SCALE
AS NOTED
JOB NO.
2021-BROWN
SHEET
S-2
OxU
z I -a
SEE WALL SECTION S-4 TRUSS
SHEET T-1 FOR NEW ROOF TRUSS
SEE NOA, ON COVER SHEET FOR
NEW ROOF TILE, SOFFIT SPECIFICATIONS
NO WORK TO WALL STUCCO
ONLY GARAGE DOOR FACE
OF WALL AND OPENING
NO WORK TO WINDOWS
EXISTING
VERIFY IN FIELD
SEE SHEET S-1
EXISTING DOOR TO REMAIN
NO WORK
SEE SHEET S-1 CONS
4000 PSI CONC FILL
\I
8' x 3/4 RAISED —
STUCCO BAND
NEW, MATCH EXISTING
WALL SECTION S-4 TRUSS
T T--1 FOR NEW ROOF TRUSS
NOA, ON COVER SHEET FOR
ROOF TILE„ SOFFIT SPECIFICATIONS
12 VERIFY
6
�!
�11
NO WORK TO WINDOW
\�
ONLY GARAGE DOOR
EXISTING
VERIFY IN FIELD
FACE
��
/
OF WALL AND OPENING
SEE NOA, ON VER SHEET cOR
\\
NEW ROOF TILE, OFFIT SPECIFIC?TIONS
12
�\
6VERIFY
\
APPLY 5/8- STUCCO TO WALL
NEW STUCCO REPAIR WORK
9'-6" AF.F, 1
ONLY GARAGE DOOR FACE
OF WALL AND THE OPENING
___+
TOP OF BEAM —�4
EXISTING VERIFY IN FIELD
�I
MATCH BACK TO ORGINAL CONDTION
I
T
I
I
I
I
Ll
EXISTING VERIFY IN FIELDS
MATCH BACK TO ORGINAIj CONDTION
8" x 3/4 RAISED STUCCO BAND
P
EXISTING
FINISH FLOOR LINE-0'
_
_L-11
__
_ _
__
170 D ZONE 12' GARAGE DOOR
/
SEE NOA, ON COVER SHEET
GRADE LINE EXISTING
AMERICAN PALM BEACH DOOR
/ VERIFY
HURRICANE MASTER MODEL 824 TS
/
12'-0"
-4
/
VERIFY
NEW OPENING
VERIFY
PARTIAL FRONT GARAGE ELEVATION
ELEVATION # 1
1/2" TOOLE[
STUCCO JOIN]
5/8 SMOOTH FINISF
STUCCO &
STUCCO BAND
ROUGH FINISF
STUCCC
VERIn
TOOLED STUCCO BAND DETAIL
EXISTING BLOCK N.T.S.
SEE NOA, SEE COVER SHEET FOR
NEW GARAGE DOOR " VERIFY
12'AGE OR VERIFY
11
'-_�111111111111111111111111111111111111111111111111111'IIIIIV='
,
:;dIIII1111111111111111111111111111111111111111111111111111L;-
PROVIDE CONTINUOUS P.T. 2x6 NAILER
AROUND GARAGE DOOR OPENING
FASTEN AT JAMBS w/ 145d x 3"
"HILT!" DRIVE PINS 0 8" O.C.
FASTEN AT HEADER w/ 6' x 1/8
U.S. ANCHOR CONCRETE SCREWS OR EQ.
0 12" O.C. PER NOA REQUIREMENTS—
O.H. GARAGE DOOR W/ TRACK ATTACHED
— TO 2x6 PER MANUF. SPECS.
1x2 TRIM CONT. w
CONT. CAULK BEAD
NEW STUCCO ON CONIC, BLOCK—/1x2 TRIM CONT. w/ STUCCO ON CONC. BLOCK
5/8" w/ CONC. FILLED CELLS CONT. CAULK BEAD w/ GONG. FILLED CELLS
VERIFY TO REMAIN TYP. EXISTING TO REMAIN
PATCH NEW WALL AS REQUIRED
NEW GARAGE DOOR ANCHORAGE DETAIL
INSTALL ALL DOORS ANCHORS PER NOA SCALE: 1\" = 1'-O"
HURRICANE MASTER MODEL 824 REQUIRFEMENTS
NOA 20-0901.25 EXP DATE JULY 31 2025
-STUCCO
ON C.B.S.
CONTINUOUS
CALK BEAD
TYP.
CONCRETE NOTES
ALL CONCRETE WORK SHALL CONFORM TO THE BUILDING CODE REQUIREMENTS
FOR REINFORCED CONCRETE (ACI 318-19 PLUS UPDATES) SPECIFICATIONS FOR
STRUCTURAL CONCRETE FOR BUILDINGS (ACI 301-16 PLUS UPDATES) OF THE
AMERICAN CONCRETE INSTITUTE.
FABRICATED IN ACCORDANCE WITH THE A.C.I. BUILDING CODE
(LATEST EDITION) AND THE LATEST MANUAL OF STANDARD PRACTICE (A.C.I.
315). SHOP DRAWINGS OF ALL REINFORCING STEEL MUST BE APPROVED BY THE
ENGINEER BEFORE FABRICATION.
CONCRETE SHALL BE A MIX DESIGNED TO SECURE A STRENGTH OF MIN
4000 PSI (UNLESS OTHERWISE SPECIFIED) AT 28 DAYS FOR THE SLAB AND
FOOTINGS SLUMP SHALL BE A MINIMUM OF 3" AND A MAXIMUM OF 5".
CONCRETE DURING AND IMMEDIATELY AFTER DEPOSITING, SHALL BE
THOROUGHLY COMPACTED BY MEANS OF MECHANICAL VIBRATION.
2X6
STUDS
® 16'
O.C. —
SIMPSON SP6 NEW [NAIL
IMPSON
AT TOP & 2X6 P6
BOTTOM TOP PER
OF EACH STUD PLATE FR.
SIMPSOIV SP6
AT TOP &
BOTTOM!
OF EACH STUD
C
24"
(2) 2X12"s
SIMPSON
MTST18
TYPICAL
1
MAX
R BOL
HURRI
NE
vv
WASHERS
a
INSIALLLU
4" O.C. - 6" MIN. SIMPSON LTT20B TO BE INSTALLED AT ALL
EMBEDMENT WALL OPENINGS, CORNERS, AND ENDINGS.
USE A 1/2" EXPANSION ANCHOR W/
A MINIMUM EMBEDMENT OF 6"YP.
HEADER BEARING 2X6 WALL DETAIL
N,T,S,
EXISTING TRUSSES
BUILDING NOTES:
THE STRUCTURE IS DESIGNED TO BE SELF-SUPPORTING AND STABLE AFTER THE BUILDING
IS FULLY COMPLETED. IT IS SOLELY THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE
ERECTION PROCEDURE AND SEQUENCE AND TO INSURE THE SAFETY OF THE BUILDING
AND ITS COMPONENT PARTS DURING ERECTION. THIS INCLUDES THE ADDITION OF
WHATEVER SHORING, SHEETING, TEMPORARY BRACING, GUYS OR TIEDOWNS WHICH MIGHT
BE NECESSARY. SUCH MATERIAL SHALL REMAIN THE CONTRACTOR'S PROPERTY AFTER
IT IS SOLELY THE CONTRACTOR'S RESPONSIBILITY TO FOLLOW ALL OSHA APPLICABLE
SAFETY CODES AND REGULATIONS DURING ALL PHASES OF CONSTRUCTION.
MECHANICAL FRAMING LOADS, OPENINGS AND STRUCTURE IN ANY WAY RELATED TO
THE MECHANICAL REQUIREMENTS ARE SHOWN FOR BIDDING PURPOSES ONLY.
CONTRACTOR TO VERIFY THAT ELECTRICAL, PLUMBING OR OTHER EXISTING ELECTRICAL
PIPING OR NEW PIPING, DUCTWORK DOES NOT CONFLICT WITH PROPOSED TRUSS LOCATIONS
CONCRETE NOTES:
ALL REINFORCING STEEL SHALL BE ASTM A615 GRADE 60.
C.I.P. CONCRETE CONSTRUCTION OR CONTROL JOINTS IN SLAB ON GRADE TO BE AS SHOWN ON
PLANS. WHERE NOT SHOWN, LIMIT CONTROL JOINT SPACING TO NO GREATER THAN 15 FEET ON
ANY SIDE FOR 5 INCH SLABS AND 12 FEET FOR 4 INCH SLABS ON GRADE. THE SECTIONS
BOUNDED BY CONTROL OR CONSTRUCTION JOINTS SHALL BE APPROXIMATELY SQUARE, WITH THE
LENGTH TO WIDTH RATIO LESS THAN 1.5.
COORDINATE CONCRETE WORK WITH ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR
ARCHITECTURAL FINISHED CONCRETE, RECESSED AREAS, EMBEDDED ITEMS, AND SPECIAL CONTROL
JOINTS.
PROVIDE DOWELS IN FOOTINGS TO MATCH VERTICAL WALL AND PIER REINFORCING. PROVIDE
CORNER BARS AT WALL AND FOOTING CORNERS TO MATCH HORIZONTAL REINFORCING. SEE BAR
SPLICE TABLE BELOW FOR MINIMUM LENGTH OF EACH LEG.
UNLESS OTHERWISE NOTED OR DETAILED, ALL REINFORCING BAR SPLICES SHALL BE IN
ACCORDANCE WITH THE TABLE SHOWN BELOW:
CONCRETE SPLICES TYPE A TYPE B
BAR (NON TOP BAR) (TOP BAR)
SIZE LENGTH (IN) LENGTH (IN)
#3 14 18
#4 19 24
#5 23 30
#6 30 40
#7 41 54
#8 55 71
#9 69 90
#10 88 114
#11 108 140
TOP BARS ARE HORIZONTAL REINFORCEMENT SO PLACED THAT MORE THAN 12 IN. OF FRESH
CONCRETE IS CAST IN THE MEMBER BELOW THE REINFORCEMENT.
PROVIDE THE FOLLOWING MINIMUM CLEAR COVER FOR REINFORCING STEEL FROM SURFACE OF
CONCRETE:
• FOR CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH:
3" IN GENERAL
2" FOR FOUR INCH SLABS ON GRADE
• FOR CONCRETE SURFACE EXPOSED TO THE WEATHER OR AGAINST WHICH BACKFILL WILL BE PLACED:
2" FOR #6 BARS AND LARGER
1-1/2" FOR #5 BARS AND SMALLER EXCEPT AS NOTED FOR PRECAST PANELS.
• FOR SURFACES OTHER THAN ABOVE:
1-1/2" FOR COLUMN SPIRALS OR TIES, OR STIRRUPS (EXCEPT PAN JOISTS)
3/4" FOR SLABS AND FOR STIRRUPS IN PAN JOISTS
TOLERANCES FOR BAR COVER ARE f 3/8 INCH FOR CONCRETE HAVING A THICKNESS OF 8
INCHES OR LESS AND t 1/2 INCH FOR CONCRETE HAVING A THICKNESS GREATER THAN 8
INCHES. TOLERANCE FOR LONGITUDINAL LOCATION OF BENDS AND ENDS OF REINFORCEMENT SHALL
BE t 2 INCHES EXCEPT AT DISCONTINUOUS ENDS OF MEMBERS WHERE THE TOLERANCE SHALL BE
t 1/2 INCH. TOLERANCE FOR BAR SPACING IS t 2 INCHES, TOLERANCE FOR LENGTH OF LAP
+SPLICE IS -1 INCH, AND TOLERANCE FOR EMBEDDED LENGTH IS t 1 INCH.
3 1/4" MIN EMBEDMENT
WITH 2" SQUARE X 1/8"
THICK HURRICANE WASHEf
" . EXTERIOR
DOOR 2X4 TRUSS® 24" OC
INSTALL 3M CP 25 WB
8 SCREWS 1 HR FIRE RATED CAULK W/ 5/8 CDX PLYWOOD W/
TO UNDERSIDE EXISTING RAFTERS VERIFY IN FIELD
1 1/4 LONG TO BOTTOMOF RAFTER TYP EXISTING TRUSSES
� ,
it !®24" O.C.
11 „ 11 ,I 11 1, ,1 �� ��
:HOOD DOOR
EXISTING RAFTERS 016" OC
JAMB ADD 5/8 CDX PLYWOOD TYP.
VERIFY IN FIELD
3/16" x 4" CORROSIVE EXISTING
RESISTANT 'iAPCON" 0 2X6 FASCIA
W/ 1/2" VENTED
CONC. SCREWS INSTALLED 18" PLYWOOD SOFFIT
1/2" GYPSUM O.C. SINGLE LEAF TO REMAIN
BOARD AND ® 12" O.C. DOUBLE R-19 INSULATION SIMPSON MTS18 SIMPSON MTS18 VERIFY IN FIELD
SHIM MATCH EXISTING HURRICANE STRAP HURRICANE STRAP
P.T. FURRING LEAF EVERY 24" OC
WOOD CASING P.T. 2 x 4 TYPICAL
TYP, EXTERI❑R DOOR JAMB DETAIL KITCHEN
INSTALL ALL DOORS ANCHORS PER NOA 3' = 1'-O' _ } GARAGE NOTE: EXISTING
BLOCK WALL
- TO REMAIN
2X6 STUDS 0 16" OC VERIFY IN FIELD
SP #2 OR BETTER W/ uj
INSTALL NEW 4" USE NEW 5/8" DRYWALL
BONDING AGENT TO 4000 PSI
CONCRETE VERIFY IN FIELD UL U 493 6" WD WALL 5/8 PLYWOOD W/
ONE (1) HR WALLW/ Sd NAILS 0 6" OC
NEW R19 INSULATION EDGE & 6" OC FIELD.
ONE (1) HR WALL
PT 2X6 PT BOTTOM PLATE
SP #2 LUMBER —�
1/2"4 ANCHOR 0 —�
24" OC & 4" FROM EXISTING FOUNDATION —
EXISTING SLAB Y ALL DOORS W/ MINIMUM 3" EMBEDDED TO REMAIN
RAISE SLAB 4'° W/ NEW HURRICANE WASHERS TYP,
VERIFY IN FIELD
INSTALL 3M CP 25 WB
1 HR FIRE RATED CAULK
TOP & BOTTOM TYP
TYP. GARAGE DOOR ANCHORAGE DETAIL
U L U 493 6" 1 HR WALL SCALE: 1\" = 1'-O"
(2) 16d ® 12" 0
Od
O.C.
DETAIL AT 900 CORNER
N.T.S.
w
0
�a
F U
OU
�a
�N
�o
ww
wo
oN
ow
�o
w�
mw
O �
z�
z
a-
`i
00
a¢
W w
� U
�s
a�
z
aw
r�
m
o�
WF
�Sa
o�
0
ww
as
z
aw
�w
oz
iz
�W
r �^
m�
W
o�
a�
00
z
wo
�a
z
¢z
mo
as
�o
za
am
a�
w?
om
w
zw
z?
�z
aw
of
as
z�
�o
ag
wm
U W
O�
U Z
�o
zw
�w
as
N V
N X2
LO
o g
Oro w d
N � p
N
r RE o�(��jj
v q
V
LLI
O
CL
}
O F
Ld M v0
E5
O lJLLJ
Of
Q Q
N (n
ox �U W
m< W
>
sa w
w a dry' m t� L
Wr �_
m V �I
a COU) Q
z
w�
o
a�
m�
N z }� r
l ) ® C�
h W 1"/ ^✓
W
0.
> U
U O
O i
Y Z
G� Zoo� t-1
a
Z
zao W
mow m
WdZI r
ry jL�,r.
a w_ W ooQ
3"J Lo W
wza
w°o
roa LlJ V1
¢
o�
wz�
>a�
U U �
K O U
O N Z
rya
ZnU
az>
=W
mU2
F
ago
ws
�¢z
WILLIAM J. MATHERS, PE
a
o = a FL �4W8 1
N ¢
L
¢ s r
58
z
m o � TATE OF
�o
w o it
o E STR
� Z W
y WUZ
�¢z
W m�
w
�mL
NOTE: M w
THE PROPOSED RENOVATIONS DO NOT STRUCTURALLY ALTER THE
REMAINING EXISTING STRUCTURAL SYSTEMS AND A REQUIREMENT w
TO UPGRADE IT BY THIS PERMIT APPLICATION IS NOT
WARRANTED. L�
h O N
wos
EXISTING BUILDINGS COMPONENTS AND ELEMENTS OUTSIDE THE
RENOVATION AREA WILL NOT HAVE THEIR CURRENT WIND LOAD oo F
RESISTANT CAPACITY COMPROMISED BY THE PROPOSED NEW �Lw
CONSTRUCTION. U
ova
APPROVAL OF THESE PLANS IN NO WAY RELIEVES THE zwW
CONTRACTOR OR BUILDER OF COMPLYING WITH ORDINANCES ° w
OF THE LOCAL, STATE OR FEDERAL JURISDICTIONS. aw
az
wo
w _
I- W
DRAWN
J.V.H.
CHECKED
W.J.M.
DATE
OCT 2021
SCALE
AS NOTED
JOB NO.
2021 -BROWN
SHEET
S - 3
NOTE: ALTERNATE NAIL - 12d GUN NAILS (3"x .128)
12 ANCHORS REQUIRED
TOP PLATE AT CORNER
SCALE: 3/4" = 1'-0"
SINGLE 2x6
TOP PLATE
2x6 TOP PLATE
SPLICE BLOCK
2x6 HEM -FIR STUDS
O 24" O.C.
NOTE: ALTERNATE NAIL - 12d GUN NAILS (3'x .128)
NOTE: 12 ANCHORS REQUIRED
TOP PLATE SPLICE
SCALE: 3/4" = 1'-O"
NEW 2x4 DIAGONAL AS SHOWN
AT GABLE END VERTICAL
NAIL DIAGONAL TO EVERY GABLE END
VERTICAL BRACE W/ (3) 16d NAILS
BRACE INSTALLED AS REQUIRED
BY TRUSS ENGINEERING
2"x4' DIAGONAL BRACING (4'-0"
FROM GABLE ND) W/ (2)-10d NAILS
O EACH DIAGONAL & (2)-10d NAILS
O EACH TRUSS WEB
BRACING PER TRUSS
ENGINEERING
INSTALL P.T. 2x4 NAILER W/
1/2' x 7" "J" BOLT OR 5/8" x 7"
EXPANSION BOLT O 24" O.C.
W/ 3" x 3" x 1/4" WASHER —
SEE FRAMING PLAN FOR
SIZE, GRADE AND QUANTITY
20go. GALV. PLATE ANCHOR
W (4) Bd NAILS EACH MEMBER,
EACH SIDE
P.T. 2X6 BOTTOM PLATE
3"X3"X1/4"
WASHER
1/2" X 8" EXPANSION
BOLTS O 18" O.C;
1/2" X 8" EXPANSION
BOLTS O 18" D.C.—
e
POST & BEARING WALL
CONNECTION DETAIL
WOOD TRUSSES AT 2'-0" O.C.
(SEE TRUSS ENGINEERING FOR
REQUIRED LOADING
2x4x8' NAILED TO BOTTOM OF
EA. TRUSS TOP CHORDS W/ (2)
10d RS NAILS.
ROOF SHEATHING (4" OC TYP ALL
CONDTIONS FOR NAILING W/ BD RS)
8d GALVANIZED NAILS
O 4" O.C. TYPICAL
DRIP EDGE
P.T. 1 x2
P.T. 1 x6
2x8 NAILED W/ 16d NAILS O 4" O.0
NOTE: ADD ADDITIONPIL LAYER OF
15# FELT PAPER 12 WIDE
N� 2 Q1Y GABLE END TRUSS
W 2X8 BOTTOM CORDS
DOUBLE GABLE END TRUSS NEW VERTICAL BRACE
BY TRUSS COMPANY SHOP DWGS
5/8" STUCCO ON MTL LATH OVER 15#
FELT PAPER ON APA RATED P.T.
15/32' EXPOSURE 1 GRADE PLY -WOOD
SHEATHING
R-19 MIN. INSULATION
NAIL BOTTOM CORD OF GABLE END
TRUSS TO P.T. 2x6 NAILER W/ 16d
NAILS O 8" O.C.
SEE SHEET T-1 FOR COL DETAILS
TIE DOWN AND ANCHOR SPEC'S
NEW P.T. tx2 FIRE STOP
w
TYPICAL 8"X16" CONC. TIE EXTEND PAPER BACKING
BEAM EXISTING
(4) #5 CONT. 12" OVER BEAM
!..... •
EXTEND LATH
12' OVER BEAM
NOTE
SEE HIB-91 BY T.P.I. FOR TEMPORARY
BRACING DURING ERECTION.
NO ADDITIONAL PERMANENT WIND BRACING
REQUIRED, OTHER THAN SHOWN ABOVE,
ON KOST TRUSS ON INDIVIDUAL TRUSS
GABLE END DETAIL ENGINEERING SHEETS.
NO WIND BRACING REQUIRED
IN FLOOR OTHER THAN
SCALE: 3/4" = 1'-0" SHOWN ON T NUEW TRUSS ENGINEERING.
1/4" CONTINUOUS
BEAD OF CAULK EXISTING CBS WALL 7
BEHIND BUCK VERIFY IN FIELD /
d
-
dl
% STUCCO/ �/ \
NEW NP-.1 CAULK
INSTALL P.T. BUCK
HILTI NAIL
CRS 099-122
O 6" O.C.
SCREEN DOOR JAMB DETAIL
d
TYP. ALUM. WINDOW JAMB
SLIDING GLASS DOOR JAMB
a
CAULK PER NOA
5/8" GREEN BD DRYWALL
4/4" x 2 3/4" SS CORROSIVE
RESISTANT 'TAPCON" ANCHORS INTO
CONC. THE SCREWS INSTALLED AS CALLED FOR
ON WINDOW PRODUCTS APPROVAL (NOA)
SCALE: 3/4" = 1'-0'
DBL STUDS AS
2"x6' RIBBON ARC
(BY BUILDER)
2"x6" BLOCKING
DBL. STUDS AS,
2"x6" BLOCKING BELOW
DBL. STUDS ABOVE
(INSIDE GABLE END
TRUSS) —�
DBL. STUDS ABOVE
209a. GALV. PLATE ANCHOR
W/ (4) 8d NAILS EACH MEMBER,
EACH SIDE
FLOOR
SEE TRI
2X6 DBL
INTERIOR
W/g (4)
AS REAL
SEE TRU
SIZE, GR
FLOOR GIRDER CONNECTION
O.0 FLOOR TRUSSES
)W SEE TRUSS SHOP DRAWINGS
SCALE: 1\" = 1'-O"
3 1/4" MIN EMBEDMENT
WITH 2" SQUARE X 1/8"
THICK HURRICANE WASHEI
(2) 16d ® 12" 0
PLAN VIEW EACH SIDE OF EACH WINDOW USE (1) 14ga STRAP
ON THE JACK STUD AND (1) 14go STRAP ON THE
FULL HEIGHT STUD. STRAPS TO BE ON THE INSIDE
OF THE WALL, EMBEDDED IN THE BEAM BELOW
INSTALL NEW CEMENT BORAL VILLA 900 TILE
NOTE: TILE NAILED ON ICE & WATER SHIELD POLY GLASS USA INC
SURFACE INSTALL W/ 30# FELT OVER THE ICE & WATER PEEL -&
STICK -TIN TAGGED W/ 16go. NON -CORROSIVE STAPLE W/ 1"
CROWN OR 12go. WIRE RING-SHANKED NAILS, 3/4" LONG
ON APA RATED 19/32" TREATED EXTERIOR
GRADE PLYWOOD SHEATHING, NAIL W/ 8d NAILS
(.131 x 2\" NAILS) 4" O.C. ALL MEMBERS. WITHIN 4'-O" OF
ROOF EDGES NAIL PLYWOOD W/ 8d NAILS 3" O.C.
WITHIN 4'-0" OF ALL ROOF EDGES).
PLYWOOD TO BE PERPENDICULAR TO TRUSSES
W/ STAGGERED JOINTS
ENGINEERED APPROVED WOOD TRUSSES O 24" O.C.
ALL TRUSS BRACING TO BE PLACED AS SHOWN ON
TRUSS ENGINEERING SHOP DRAWING SHEETS
18 ga. MTS 18" WIDE SIMPSION GALV. STL. STRAP
AT EA. TRUSS (SEE ANCHORING SCHEDULE)
BY TRUSS ENGINEER
SEE SHEET T-1 FOR COL DETAILS 2X6 SUB FASCIA W/
TIE DOWN AND ANCHOR SPEC'S 1X2 FASCIA W/ 1X2
METAL DRIP
AK VERIFY / MATCH EXIST I i
SEE WALL SECTION S-4 TRUSS
SHEET T-1 FOR NEW ROOF TRUSS
SEE NOA, CV-1 COVER SHEET FOR 1.
NEW ROOF TILE, SOFFIT SPECIFICATIONS
VERIFY EXISTING
CBS BLOCK
NAILED TO THE STUDS W/ (8) 16d NAILS. DETAIL AT 900 CORNER
NAIL EXTERIOR PLYWOD TO BOTH STUDS W/ 8d
NAILS O 4" O.C., SOLID BLOCKING REQ'D. IN N.T.S.
FLOOR TRUSS SPACE BELOW DBL. STUDS ABOVE
(FLOOR TRUSSES BELOW DBL STUDS WILL
SUBSTITUTE FOR BLOCKING)
DBL. STUDS ABOVE
149a. STRAP FROM STUDS TO
BEAM BELOW SEE T-1
2"x6' RIBBON AROUND PERIMETER
(BY BUILDER) NAIL TO
TRUSS W/ (8) 16d NAILS --
PLAN VIEW 2"x4' BLOCKING BELOW
DBL. STUDS ABOVE
2x4 P.T. BLOCK (COR
PARTIAL 2X6 SECTIONS W/ 1
BETWEEN TRUSSES) W/ 1 /2" "J"
BOLTS O 18" O.C.
SCALE: 3/4" = 1'-O"
I�I��
�II�O�11�11�11�\
NO WIND BRACING REQUIRED
IN FLOOR TRUSSES OTHER THAN
SHOWN ON TRUSS ENGINEERING.
EXISTING WALL VERIFY EACH LOCATION
W/ (3) 16d RS NAILS FOR EACH
TRUSS VERIFY WALL LOCATIONS
ROOF BRACING DETAIL
NOTE:
THESE PLANS AND ALL ASSOCIATED DOCUMENTS ARE VALID FOR REPAIR
CONSTRUCTION ONLY UPON STAMPED APPROVAL FROM APPROPRIATE
GOVERNING JURISDICTION. THESE PLANS ARE VOID AND SHALL NOT BE
USED FOR CONSTRUCTION OR ANY OTHER PURPOSE WITHOUT THE
CITY OF STUART BUILDING DEPARTMENT 1?EVIEW AND APPROVAL.
NEW FLOOR TRUSSES
O 24" O.C. SEE TRUSS PLAN
BY TRUSS ENGINEER
11111
NOTE: VERIFY EXISTING JOIST
NOT ALL FLOOR SECTIONS
HAVE EPICORE DECK UNDERSIDE
..y
_•;
i�.
'*_"
TO REMAIN VERIFY IN FIELD
A.
1, 1'.
EXISTING TIE BEAM TO REMAIN
•
ABOVE WINDOWS & DOORS
VERIFY IN FIELD
PARTIAL WALL SECTION
NOTE -NOT ALL FLOOR SECTIONS SCALE: 3/4" = 1'-0"
HAVE ENCORE DECK UNDERSIDE
N 2x6 BRACE O 24" OC
W() 16d NAILS IN TO
& B BRACING
SCALE: 1/2" 1'
5\8" G
BOARD
P.T. FU
WOOD L.........
STUCCO
ON C.B.S.
CONTIN. CAULK
NP-1 BEAD
BRICK MOLD
OPTIONAL
EXTERIOR
DOOR
WOOD DOOR
JAMB
#8 SCREW
1 I" LONG
0 24" O.C.
HILTI NAIL
CRS 099-122
O 6" O.C.
SHIM
P.T. ix4
SCALE: 3" = 1'-O"
Nlgri'1
SEE COVER SHEET FOR NQA'S
SEE WALL SECTION AND TRUSS
SHEET T-1 FOR NEW ROOF TRUSS
SEE NOA, ON COVER SHEET FOR
NEW ROOF TILE, SOFFIT SPECIFICATIONS
VERIFY
12
6F—
INSTALL NEW
R-19 (MIN.) INSULATION
INSTALL NEW
5/8" GYP. BOARD
" SG GREEN BD" TYP
P.T. i "x2" FIRE STOP
DOUBLE 2"x6" TOP PLATE
USE 2X6 U STRAP TYP
SIMPSION PER MFR INSTALL
TOP & BOTTOM TYP.
WU
r�
d
r�
O U
iw
� L1
,F
U
aG
it
wo
s�
a rc
oN
L, o
�m
wz
mw
o�
z�
J N
11
c
za
o�
aQ
w�
ww
0
pp
o
O -
z
3a,
0o
I
r
o
O
'0
00
CN
W
,z
N
Q�
pL
r
�S
=w
W
o
((
ma
O
!J
o�
w �
u
_
�o
tia
z
}
m
zJ
_
00)
nnnnnn
V
W M
s
w
X
J
�w
zz
x LL
5/8" GYP. BOARD (M-R. IN BATHS) W/ 11" TYPE 2 W I.-r
S OR W #6 DRYWALL SCREWS O 6" O.C. N
ALL MEMBERS TYP. o w D
2"x6" #2 (STUD GRADE) HEM -FIR J a N
_ WOOD STUDS O 12" O.C. W/ SINGLE
TOP PLATE (STUDS TO ALIGN W/
Bo w TRUSSES ABOVE o 0
> 2"x6 BLOCKING O PLYWD. SEAM
NAIL PLYWD. TO BLOCKING W/ �, w
8d NAILS O 4" O.C. oz a
NEW R-19 (MIN.) INSULATION
a�
NAIL BOTTOM PLATE TO RIBBON o
W/ 16d NAILS O 4" O.C.
aw
NEW WOOD BASE
aW
APA RATED "STURD-1-FLOOR" OR EQ 48/24 - 23/32'
EXPOSURE-1 GRADE PLYWOOD SET ON A CONT. r ,
1/4" DIRA BEAD OF LIQUID NAIL FLOOR PANEL ADHEASIVE F+i
AND" NAILED W/ 10d RING SHANK NAILS
O 60/C IN FIELD O 3' O.C. AT EDGES �Uj m
EDGES (O BATHROOMS PROVIDE ADDITIONAL o> F-+ W z
LAYER 32/16 - 15/32" EXPOSURE-1 GRADE PLYWD. '„0
SET OVER 15# FELT & NAILED O 12" O/C W/ w a
8d RING SHANK NAILS) f--I f ;
18" DEEP FLOOR TRUSSES �W INSTALL 3/4" APA RATED t
a O 24' O.C. SEE TRUSS PLAN a ((�(���,,,,^��,,'� eeeee�--1I«---111
n BY TRUSS ENGINEER EXPOSURE 1 GRADE P.T. PLYWOOD w m
SEE SHEET T-1 FOR COL DETAILS a W
TIE DOWN AND ANCHOR SPEC'S ^'_
SEE FLOOR TRUSS FRAMING PLAN z " ` E-i
- FOR FIRESTOP EACH JOIST
LOCATIONS O ,°-' z O r ,� Q 1,4 w
FLOOR TRUSSES TYP. w z W
l z '.:I
'. r.. NOTE VERIFY EXISTING a M r ,
6" E VERIFY
FY EXISTING
SLAB DECK 4+-i
TO REMAIN LOCATE IN FIELD =o°- F"-i
P.T. i "x2" FIRE STOP i UN.2
R W INSTALL NEW rave a ? ^ O
"5/8" GYP. BOARD z>om W
USG GREEN BD" TYP o �,
EXISTING TIE BEAM TO REMAIN �^ � `" z
ABOVE WINDOWS & DOORS w a a N W^^
VERIFY IN FIELD a r-i V 1
Lo
ow
m
wza > LO
So
o
5/8" GYP. BOARD ON w�a a a
P.T. 1 x 2 FURRING STRIPS = Q e�
O 24" O.C. ,z., o z
0 w
a
PT 1 X2 FURRING O 16" OC `; o
W/ CELOTX FOAM INSULATION _ a �
TYP W/ 5/8" DRYWALL OPTION `w' -"
sow
FZz
_ w
w�
„J
Qom
za
a `_u�=w
--EXISTING CMU TO REMAIN a
B" CONCRETE BLOCK WALL w w > WILLIAM J. MATHERS, PE
a ` FL #.19658
R-11 INSULATION BETWEEN �'� z
P.T. 1 "x2" FURRING STRIPS
O 24" D.C. "
ma
010 ,Z VC
— INSTALL NEW WOOD BASE
4" THICK EXISTING CONCRETE m •O L OF
SLAB VERIFY IN FIELD
NOTE: EXISTING CONC.
c * .
o.
w STRIICf /L
zw
EXISTING SLAB T
a 14 x(18" MONOLITHIC FIG.
_EXIS?I2NG#FOOBTER /AS 0\\�
11zo
zoo
w
CIJ
CIO �
csw
Ww�
TYPICAL 2—STORY WALL SECTION w
w�
W�a
SCALE: 3/4" 1'-0"w
zz
izo
z
wwo
cs�
z-a
7/8" STUCCO ON MTL LATH
OVER 15# FELT ON 32/16 -
15/32" EXPOSURE 1 GRADE
PLYWOOD SHEATHING
NAILED W/ 8d NAILS 6" O.C.
FIELD ALL MEMBERS, 4" O.C. EDGES
ALTERNATE NAIL - .113 x 2€" O
4" O.C. FIELD ALL MEMBERS, 3" O.C.
EDGES
INSTALL SIMPSION
GALV. STL STRAP MTS 24
FROM FLOOR TRUSS TO WOOD
STUD. USE SAME STRAP & NAIL
PATTERN AS REQ'D FOR TRUSS
ABOVE
HOLD FLOOR TRUSSES BACK
1/2' FROM FACE OF
CBS TO RECEIVE PLYWOOD
-NAIL PLYWD. TO RIBBON,
TRUSS. & PLATE W/ 8d NAILS
O 3" O.C.
2'x6' RIBBON AROUND PERIMETER
(BY BUILDER) NAIL TO
TRUSS W/ (4) 16d NAILS—
DBL END
VERTICAL IN TRUSS
GALV. STL. STRAP POWER DRIVE
EMBEDDED INTO CONC TO TRUSS TYP
SEE SHEET T-1 FOR COL DETAILS
TIE DOWN AND ANCHOR SPEC'S
SEE FLOOR PLAN & ELEVATIONS c
FOR LINTEL BLOCK HEIGHT
STUCCO CONTROL JOINT —�
2x4 P.T. BLOCK (CONTIN. OR
BETWEEN TRUSSES) W/ 1/2" 'J'
BOLTS O 24" O.C. OR HILTI
DRIVE PINS .145"x3" O 4" O.G-
EXTEND 15# FELT PAPER
6" BEYOND FLOOR TRUSS —
EXTEND METAL LATH 12"
BEYOND FLOOR TRUSS
PATCH 5/8" STUCCO ON C.B.S. VERIFY IN FIELD
SEE SHEET T-1 FOR COL DETAILS
TIE DOWN AND ANCHOR SPEC'S
NOTE: VERIFY EXISTING ��\\
STUCCO STOP AS . PT.
PER COUNTY BLDLD G. DEPT.
TERMITE TREAT ALL NEW WALLS
TYPICAL
NOTE: VERIFY EXISTING
FINISH FLOOR LINE
NOTE: VERIFY EXISTING
APPROX. GRADE "I,
•
DRAWN
J.V.H.
CHECKED
W.J.M.
DATE
10/21/21
SCALE
AS NOTED
JOB NO.
2021—BROWN
SHEET
s-4
ro
I
SEE TYPICAL WALL SECTION
FOR NEW ROOFING NOTES
SHEET S-4
18'-1" A.F.F.
TOP OF BEAM
VERIFY SEE SHEET T-'
NEW 8" STUCCO DETAIL
BAND MATCH EXISTING STUCCO
TYPICAL
,'6 10`0" VERIFY
Y 2 ND FINISH FLOOR LINE
SEE BLOCK DETAIL
MATCH EXISTING STUCCO
TYPICAL
IXISTING V.I.F.
GRADE
SEE TRUSS ENGINEERING FOR ROOF DETAILS
TRUSS SPECIFICATIONS
VERIFY PITCH SEE SHEET T-1
12
5 rVERIFY
`— + 26'-1" A.F.F�
TOP OF BEAM
INSTALL NEW 5/8" WIDE TOOLED
STUCCO BAND OVER 3/4' PLYWOOD OVER
2 (TWO) LAYERS OF PEEL & STICK
(SEE DETAIL S-4 WALL SECTION)
SEE TRUSS SHOP DRAWINGS
INSTALL ALL NEW WINDOWS PER NOA
SEE CVR SHEET-1
i
I
II
VERIFY EXISTING
REAR ELEVATION
1/2" TOOLED
STUCCO JOINT
5/8" SMOOTH FINISH
STUCCO &
STUCCO BANDS
g
o
LLI
Lj
V))
o
f3.1�IeL'I
TOOLED STUCCO BAND DETAIL
EXISTING BLOCK N.T.S.
+ 18'-1" A.F.F.
.4,
- TOP OF BEAM �1-
VERIFY SEE SHEET T-1
5' WIDE TOOLED
TUCCO BAND
SI-E DETAIL )
TYPICAL
0'-0"
2 ND FINISH FLOOR LINE
INSTALL ALL WINDOWS PER NOA
SEE CVR SHEET-1
==_FINISH FLOOR LINE 0'-0
EXISTING V.I.F. Y
SCALE: 1/4"
WALL LEGEND
EXISTING 8" WALL
NO WORK 0
NEW 4" R-19 WALL
NEW 8" BLOCK WALL W/
FILLED CELL 4000 PSI
NEW 4' WALL
W/ NEW 5/8
DRYWALL BOTH SIDES
NEW 4" TUBE COL ON TOP OF BEAM
VERIFY IN FIELD
SEE DETAILS ON SHEET T-1
O
14'-8"
VERIFY OPENING
I
CUSTON SHELF SYSTEM
i M CLOSET
8'-4" CEIL.
I
L
r CUSTON SHELF SYSTEM CLOSET
SM.CLOSET
8'-4" CEIL.
I— -- — — — — — — -- — — — --
STRUCTURAL WALL TO REMAIN
I
I
I
I
OPEN
BELOW
ED
I
M
I
ti
NEW 4" TUBE COL ON TOP OF BEAM
VERIFY IN FIELD
30'-0" SEE DETAILS ON SHEET T-1
BEAM BELOW TO REMAIN O¢
MASTER SUITE
9'-4" CEIL
EXISTING
SPIRALOSTAIR
VERIFY IN FIELD
LINE OF PORCH WALL BELOW DOTTED
4'-8"
MIN OPENING
HALL
VAULT CEIL.
NEW 4" TUBE COL ON TOP OF BEAM
VERIFY IN FIELD
SEE DETAILS ON SHEET T-1
9'-0"
L
SINK SINK m
m �
M BATH r
w VAULT CEIL.
Y 00
a
o
"' 3'-4"
�rcrvnv�a
=1N FlEID—_
3'-9-
MIN.
NOTE:
THE PROPOSED RENOVATIONS DO NOT STRUCTURALLY ALTER THE
REMAINING EXISTING STRUCTURAL SYSTEMS AND A REQUIREMENT
TO UPGRADE EXISTING WINDOWS BY THIS APPLICATION
IS NOT WARRANTED, FOR THIS PERMIT..
EXISTING BUILDINGS COMPONENTS AND ELEMENTS OUTSIDE THE
RENOVATION AREA WILL NOT HAVE THEIR CURRENT WIND LOAD
RESISTANT CAPACITY COMPROMISED BY THE PROPOSED NEW
CONSTRUCTION.
APPROVAL OF THESE PLANS IN NO WAY RELIEVES THE
CONTRACTOR OR BUILDER OF COMPLYING WITH ORDINANCES
OF LOCAL, COUNTY STATE OR FEDERAL JURISDICTIONS.
a0
12"
13'-3"
VERIFY IN FIELD
OPENING
NOTE: 1. SEE AMERICAN STANDARD SPEC'S FOR MANUFACTURERS NUMBERS
FOR TOILET ACCESSORIES.
2. ALL TOILET PARTITIONS SHOWERS DIMENSIONS ARE CENTER LINE
OF PARTITION. (WHEN USED)
3. CONTRACTOR TO USE PLYWOOD BACKING BOARD FOR ALL NEW
GRAB BARS, SHELVES & ACCESSORES TYPICAL VIF.
NOTE:
SEE FOUNDATION PLAN FOR ELEVATOR
FOR LOCATION & PLAN DETAILS
SEE ELEVATOR SHOP DRAWINGS
FOR TYPE, ELECTRICAL CONNECTIONS, MODEL
SPECIFICATIONS ALL UNDER SEPARATE STATE FL
PERMIT -VERIFY IN FIELD TYP.
PAD LOCATION & PLAN DETAILS
SEE ELEVATOR SHOP DRAWINGS
FLA STATE PERMIT -VERIFY IN FIELD TYP.
SCALE: 1/4" = 1
NOTE: ADDITION/ALTERATION
F.B.C. 7th ED. 2020 EXISTING BUILDING
ADDITION: AN EXTENSION OR INCREASE IN FLOOR AREA, NUMBER OF STORIES
OR HEIGHT OF A BUILDING OR STRUCTURE.
ALTERATION: ANY CONSTRUCTION OR RENOVATION TO AN EXISTING
STRUCTURE OTHER THAN REPAIR OR ADDITION. ALTERATIONS ARE CLASSIFIED
AS LEVEL 1, LEVEL 2, LEVEL 3.
THIS PROJECT IS CLASSIFIED AS ADDITION. LEVEL 1
NOTE:
THESE PLANS AND ALL ASSOCIATED DOCUMENTS ARE VALID FOR CONSTRUCTION
ONLY UPON STAMPED APPROVAL FROM APPROPRIATE GOVERNING JURISDICTION.
THESE PLANS ARE VOID AND SHALL NOT BE USED FOR CONSTRUCTION OR ANY
OTHER PURPOSE WITHOUT BUILDING DEPARTMENT REVIEW AND APPROVAL.
�n
o�
�2
�N
os
w�
U
�Y
00
Y �
aw
Ys
Y�
o�
wLL
wo
�F
mw
z�
x`
00
z�
"a
ww
YK
a3
a�
x
m
o�
w�
n o
ow
0
wa
Qa
o
�o
�z
a�
cw
z
�w
}w
nl
o?
Wa
a�
U w
00
x
z K
we
wY
o.
a
Yo
Y
as
oY
zo
as
w
�o
a�
z
c w.
z
ww
F N
0
of
s
zi
wo
wz
�o
U �
oa
U Z
a�
�o
�N
rw
Y
oa
c� w
LO
LO
0 a O
O o o >Zy
00
N A
N O
0
W N)
X o
Es LLLJ
W I..
to WW
0_
Q
Q J
U
ccli N
Z
}m
HQ
Z
QO
m~
W
an
W
zw
zi
0 0
00
o i
wZ,
how
�Q
zoz
ca,
,a
1iw
ao�
a U
.yo
zao
oin
< Q -
a��
how
ry
waz
W
i
"n
�N
^'
<a
} a
n_a
zo_
O G
a
U i �
a o�
a
>q3
U U �
YOU
DRAWN
J.V.H
CHECKED
W.J.M.
DATE
OCT 2021
SCALE
AS NOTED
JOB NO.
xxxx-xx
SHEET
s-5
ALL REINFORCING STEEL SHALL BE ASTM A615 GRADE 60.
C.I.P. CONCRETE CONSTRUCTION OR CONTROL JOINTS IN SLAB ON GRADE TO BE AS SHOWN ON
PLANS. WHERE NOT SHOWN, LIMIT CONTROL JOINT SPACING TO NO GREATER THAN 15 FEET ON
ANY SIDE FOR 5 INCH SLABS AND 12 FEET FOR 4 INCH SLABS ON GRADE. THE SECTIONS
BOUNDED BY CONTROL OR CONSTRUCTION JOINTS SHALL BE APPROXIMATELY SQUARE, WITH THE
LENGTH TO WIDTH RATIO LESS THAN 1.5.
COORDINATE CONCRETE WORK WITH ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR
ARCHITECTURAL FINISHED CONCRETE, RECESSED AREAS, EMBEDDED ITEMS, AND SPECIAL CONTROL
JOINTS.
PROVIDE DOWELS IN FOOTINGS TO MATCH VERTICAL WALL AND PIER REINFORCING. PROVIDE
CORNER BARS AT WALL AND FOOTING CORNERS TO MATCH HORIZONTAL REINFORCING. SEE BAR
SPLICE TABLE BELOW FOR MINIMUM LENGTH OF EACH LEG.
UNLESS OTHERWISE NOTED OR DETAILED, ALL REINFORCING BAR SPLICES SHALL BE IN
ACCORDANCE WITH THE TABLE SHOWN BELOW:
CONCRETE SPLICES TYPE A TYPE B
BAR (NON TOP BAR) (TOP BAR)
SIZE LENGTH (IN) LENGTH (IN)
#3 14 18
#4 19 24
#5 23 30
#6 30 40
#7 41 54
#8 55 71
#9 69 90
#10 88 114
TOP BARS ARE HORIZONTAL REINFORCEMENT SO PLACED IT AT MORE THAN 12 IN. OF FRESH
CONCRETE IS CAST IN THE MEMBER BELOW THE REINFORCEMENT.
PROVIDE THE FOLLOWING MINIMUM CLEAR COVER FOR REINFORCING STEEL FROM SURFACE OF
CONCRETE:
• FOR CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH:
3" IN GENERAL
2" FOR FOUR INCH SLABS ON GRADE
• FOR CONCRETE SURFACE EXPOSED TO THE WEATHER OR AGAINST WHICH BACKFILL WILL BE PLACED:
2" FOR #6 BARS AND LARGER
1-1/2" FOR #5 BARS AND SMALLER EXCEPT AS NOTED FOR PRECAST PANELS.
• FOR SURFACES OTHER THAN ABOVE:
1-1/2" FOR COLUMN SPIRALS OR TIES, OR STIRRUPS (EXCEPT PAN JOISTS)
3/4" FOR SLABS AND FOR STIRRUPS IN PAN JOISTS
TOLERANCES FOR BAR COVER ARE t 3/8 INCH FOR CONCRETE HAVING A THICKNESS OF 8
INCHES OR LESS AND t 1/2 INCH FOR CONCRETE HAVING A THICKNESS GREATER THAN 8
INCHES. TOLERANCE FOR LONGITUDINAL LOCATION OF BENDS AND ENDS OF REINFORCEMENT SHALL
BE t 2 INCHES EXCEPT AT DISCONTINUOUS ENDS OF MEMBERS WHERE THE TOLERANCE SHALL BE
t 1/2 INCH. TOLERANCE FOR BAR SPACING IS f 2 INCHES. TOLERANCE FOR LENGTH OF LAP
SPLICE IS -1 INCH, AND TOLERANCE FOR EMBEDDED LENGTH IS t 1 INCH.
ALL CONCRETE WORK SHALL CONFORM TO THE BUILDING CODE REQUIREMENTS
FOR REINFORCED CONCRETE (ACI 318-19 PLUS UPDATES) SPECIFICATIONS FOR
STRUCTURAL CONCRETE FOR BUILDINGS (ACI 301-16 PLUS UPDATES) OF THE
AMERICAN CONCRETE INSTITUTE.
FABRICATED IN ACCORDANCE WITH THE A.C.I. BUILDING CODE
(LATEST EDITION) AND THE LATEST MANUAL OF STANDARD PRACTICE (A.C.I.
315). SHOP DRAWINGS OF ALL REINFORCING STEEL MUST BE APPROVED BY THE
ENGINEER BEFORE FABRICATION.
CONCRETE SHALL BE A MIX DESIGNED TO SECURE A STRENGTH OF MIN
4000 PSI (UNLESS OTHERWISE SPECIFIED) AT 28 DAYS FOR THE SLAB AND
FOOTINGS SLUMP SHALL BE A MINIMUM OF 3" AND A MAXIMUM OF 5".
CONCRETE DURING AND IMMEDIATELY AFTER DEPOSITING, SHALL BE
THOROUGHLY COMPACTED BY MEANS OF MECHANICAL VIBRATION.
GENERAL NOTES:
1. CONTRACTOR SHALL VERIFY ALL CONDITIONS AT THE BUILDING AND
NOTIFY THE OWNER OF ANY DISCREPANCIES BEFORE PROCEEDING
WITH ANY WORK.
2. CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR FABRICATION
PROCESSES AND CONSTRUCTION TECHNIQUES (INCLUDING
SCAFFOLDING, BRACING, SHORING, ERECTION, ETC.) FOR
COORDINATION OF VARIOUS TRADES, FOR SAFE CONDITIONS ON THE
JOB SITE, AND FOR COMPLETE COMPLIANCE WITH THE WILUAM
STEIGER OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 (OSHA).
3. DO NOT SCALE DRAWINGS.
4. CONTRACTOR SHALL THOROUGHLY FAMILIARIZE THEMSELF WITH THE
DRAWINGS WHICH, IN TURN, MAY AFFECT THE COST OF THE PROPER
COMPLETION OF THE WORK HEREIN SPECIFIED, AND CONTRACTOR
SHALL INCLUDE EVERYTHING REQUISITE AND NECESSARY TO THE
ENTIRE FINISHING OF THE WORK, NOT WITHSTANDING THAT EVERY
ITEM NECESSARILY WORK BY REQUIRED SUCH
Q S C K IS NOT SPECIFICALLY
MENTIONED OR SHOWN. CONTRACTOR SHALL FURNISH ALL LABOR
AND MATERIAL NECESSARY FOR THE COMPLETION OF ALL WORK AND
DEMOLITION HEREINAFTER DESCRIBED.
5. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE CODES
AND/OR REGULATIONS OF ALL COUNTY, STATE OF FLORIDA, F.B.C.
2020 7TH EDITION AND ALL OTHER CODES, AND/OR REGULATIONS
BY ANY OTHER AUTHORITIES HAVING JURISDICTION OVER THE WORK.
6. PROTECT EXISTING ADJACENT BUILDING STRUCTURES, FLOOR DECK
AND GROUNDS FROM ANY DAMAGE WHICH MAY OCCUR DURING
PERFORMANCE OF ALL WORK. ANY DAMAGE TO EXISTING FACILITIES
TO REMAIN WILL BE REPAIRED, REPLACED OR RESTORED TO THE
ORIGINAL CONDITION AND TO SATISFACTION OF ENGINEER AT THE
CONTRACTOR'S EXPENSE.
7. CONTRACTOR SHALL MAKE NO CHANGES WITHOUT WRITTEN
APPROVAL FROM THE ENGINEER
8. GENERAL CONTRACTOR SHALL COORDINATE AND OBTAIN ALL
PERMITS REQUIRED TO COMPLETE THE CONSTRUCTION OF THE WORK
AS INDICATED ON THE DRAWINGS.
9. GENERAL CONTRACTOR SHALL INCLUDE IN THE BASE BID ALL FEES
ASSOCIATED WITH THE CONSTRUCTION OF THIS PROJECT, INCLUDING
BUT NOT LIMITED TO PERMIT FEES, DUMP FEES, SUBCONTRACTOR
PERMIT FEES, DEMO AND IMPACT FEES.
10. CONTRACTOR IS TO COORDINATE AND ORGANIZE THE CONSTRUCTION
PROCESS AND COMPLETE SAME IN A MANNER WHICH LEAST IMPACTS
THE ADJOINING COMMON AREAS, IN ORDER TO MINIMIZE
INCONVENIENCE TO THE TENANT.
11. CONTRACTOR SHALL VERIFY FINAL SELECTION OF FINISHES FOR
DOOR & ELEC WORK WITH TENANT/OWNER BEFORE PROCEEDING WITH
ANY NEW WORK.
12. IF DISSIMILAR METALS ARE TO BE JOINED, ENGINEER APPROVED
INSULATION UNIONS MUST BE APPROVED.
CONSTRUCTION NOTES:
1. ALL CONCRETE WORK SHALL CONFORM TO THE BUILDING CODE REQUIREMENTS
FOR REINFORCED CONCRETE (ACI 318-19 PLUS UPDATES) & SPECIFICATIONS
FOR STRUCTURAL CONCRETE FOR BUILDINGS (ACI 301-16 PLUS UPDATES)
OF THE AMERICAN CONCRETE INSTITUTE.
2, FABRICATED IN ACCORDANCE WITH THE A.C.I. BUILDING CODE
(LATEST EDITION) AND THE LATEST MANUAL OF STANDARD PRACTICE (A.C.I.
315). SHOP DRAWINGS OF ALL REINFORCING STEEL MUST BE APPROVED BY
THE ENGINEER BEFORE FABRICATION.
3. CONCRETE SHALL BE A MIX DESIGNED TO SECURE A STRENGTH OF MIN
5000 PSI AT 28 DAYS FOR THE NEW WALL AND
SLUMP SHALL BE A MINIMUM OF 3" AND A MAXIMUM OF 5".
CONCRETE DURING AND IMMEDIATELY AFTER DEPOSITING, SHALL BE
THOROUGHLY COMPACTED BY MEANS OF MECHANICAL VIBRATION.
4. Note: Bridging truss design is the responsibility of the manufacturer
since added bridging may be necessary to resist uplift. Joist
manufacturer shall design the joists and bridging for uplift and
submit design calculations verifying uplift capacity and capacity
of special joists to carry all design loads. Calculations shall be
stamped by a Registered Professional Engineer in the State of
Florida.
5. LIGHT GAGE METAL FRAMING
Material, design and manufacture shall be in accordance with the "Cold
Formed Steel Design Manual of the American ran and Steel Institute.
Provide tracks, blocking, lintels, clip angles, joist bridging, shoes,
reinforcements and accessories to provide a complete metal frame
system in accordance with manufacturers recommendations.
6. Any or all prints or duplications obtained from these plans are valid only if
signed and sealed by a registered professional engineer representing
Mathers Engineering engineer of record.
All construction shall comply with Local, State, and National Codes.
7, All manufactured items shall be applied or installed in accordance with
manufacturer's specifications and recommendations. And Product NOA'S
8. LUMBER:
All lumber shall be Southern Yellow Pine or Western Red Cedar surfaced
four sides. Southern Yellow Pine shall be treated with chromated
copper arsenate (CCA) 0.40 LBS/CF of retention.
Stringers, cross members, rails, wood post, nailers, and blocking shall be NO.2
or better in accordance with southern pine inspection bureau grading rules.
All sizes as shown on plans.
Decking if used shall "composite DECKING" in accordance with
ALL NOA. PRODUCT APPROVALS All sizes as shown on plans
and fastened using stainless steel or double hot dipped galvanized deck screws.
HARDWARE:
All hardware shall be new 316 GRADE stainless steel,
All thur bolts AND ANCHOR CLIPS S.S. 316 GRADE TYPICAL
All concrete masonry units shall be normal weight aggregate; see
DESIGN DATA for required prism strength.
All reinforcing steel shall be ASTM A615 Grade 60.
The masonry contractor is to provide vertical bar positioners on
all vertical bars to maintain reinforcing in the proper location.
Unless otherwise noted or detailed, all reinforcing bar splices
shall be in accordance with the table shown below:
Bar Size #3 #4 #5 #6 #7
Lap Length (in) 16 24 32 40 48
The general contractor shall provide 7 and 28 day strength testing
on the mortar and grout used in the filling of the masonry cores
and shall submit mix to the engineer for approval.
All masonry walls shall have horizontal galvanized masonry joint
reinforcement at 16 in. o/c. Minimum wire size for the lon—
gitudinal wires shall be 9 gauge unless noted otherwise on plans
or specifications. The minimum lap length for the horizontal shall
be 7 1/2 inches unless noted otherwise on contract documents.
Provide ladder type joint reinforcing at single wythe walls.
Joint reinforcing at exterior walls shall be
hot dip galvanized. Joint reinforcing shall be discontinuous at
masonry control joints and building expansion joints.
Use type S mortar conforming to ASTM C 270.
FORMWORK
Contractor shall design and erect formwork in strict compliance with
ACI 347. See typical details for Camber requirements. Contractor shall
coordinate all openings as required for other trades. Openings where
show on the structural drawings are to identify design intent only. The
specific dimensions and locations shall be furnished or confirmed by
the trade requiring the opening. Provide chamfers at all corners in
concrete members exposed to view. Formwork to remain in place until
concrete has attained enough strength to support all dead loodds
plus a minimum of 50 PSF of additional construction load.
CONTRACTOR SHALL BE RESPONSIBLE FOR...
Contractor shall be responsible for protecting adjacent structures, streets,
and sidewalks during excavation and construction. Contractor to verify all
dimensions in field. Contractor shall work this set of drawings in conjunction
with architectural and mechanical drawings for size, shape and location of
slab openings. All sleeves, conduits, inserts, block -outs, bolts, plumbing items
and drains shall be secured in place before pouring concrete.
If any errors, discrepancies, conflicts or omissions appear in the drawings,
specifications, or other documents, the contractor shall notify hte engineer in
writing of such errors, discrepancies, conflicts or omissions prior to
proceeding with any work which appears in question.
The contractor shall use the structural drawings together with the
architectural, mechanical, and electrical drawings to locate depressed slabs,
slopes, drains, outlets, recesses, openings, reglets, bolt settings, sleeves,
dimensions, etc. Potential conflicts shall be transmitted to the
architect —engineer before proceeding with any work which appears in question.
No shop drawings shall be submitted for Engineer review until after they have
been reviewed by the contractor and noted for dimensioning, quantities and
coordinated with other trade requirement and stamped with the contractor's
approval seal. Engineer assumes no resposibility for dimensions, quantities,
errors or omissions as a result of checking and reviewing any shop drawings.
Any errors or omissions must be made good by contractor, irrespective of
receipt, checking, or review of shop drawings by engineer and even though
work is done in accordance with such drawings.
NOTE:
THE PROPOSED RENOVATIONS DO NOT STRUCTURALLY ALTER THE
REMAINING EXISTING STRUCTURAL SYSTEMS AND A REQUIREMENT
TO UPGRADE IT BY THIS PERMIT APPLICATION IS NOT
WARRANTED.
EXISTING BUILDINGS COMPONENTS AND ELEMENTS OUTSIDE THE
RENOVATION AREA WILL NOT HAVE THEIR CURRENT WIND LOAD
RESISTANT CAPACITY COMPROMISED BY THE PROPOSED NEW
CONSTRUCTION.
APPROVAL OF THESE PLANS IN NO WAY RELIEVES THE
CONTRACTOR OR BUILDER OF COMPLYING WITH ORDINANCES
OF LOCAL, STATE OR FEDERAL JURISDICTIONS.
NOTE:
THESE PLANS AND ALL ASSOCIATED DOCUMENTS ARE VALID FOR REPAIR
CONSTRUCTION ONLY UPON STAMPED APPROVAL FROM APPROPRIATE
GOVERNING JURISDICTION. THESE PLANS ARE VOID AND SHALL NOT BE
USED FOR CONSTRUCTION OR ANY OTHER PURPOSE WITHOUT THE
CITY OF STUART BUILDIING DEPARTMENT REVIEW AND APPROVAL.
U
W
7
W �
S �
F d
H U
O (J
2 W
_N
W
o=
o�
aw
W V
�w
ON
wLL
N O
mw
o�
N
�z
a-
_
N a
00
z�
¢¢
iX
WW
a�
0
Q�
m
oz
W�
3a
o�
0
wa
¢o
U
00
z
3�
¢W
�W
oz
s=
W
m�
W
o�
Wa
Q�
s�
z
}
wa
c� a
z
az
�o
¢
o�
z�
a°
U
W z
o�
�w
z=
aw
y
of
as
z�
UW
�o
WZ
�o
N�
VW
�W
oa
UZ
13
�o
2 W
�w
oax
U W
N
O
8
I
CO a
CO w
N
h �
r
O
w
Z
0
a_
°R
2 00)
0) PM
0) /�
w � v�
Es noEs L_J
wF
N
Of
`Z
Q J
N U)
t�
•
i
•
•
•
•
•
WILLIAM J. MATGHERS, PE
FL#119,6Y6ili! 'rJ
658
DRAWN
J.V.H.
CHECKED
W.J.M.
DATE
10/21 /21
SCALE
AS NOTED
JOB NO.
2021-BROWN
SHEET
S-6
ROOF- PLAN
INU 1 NUJJ WUNK I U LJCIJ I II\JU NUUt-
MATCH EXISTING PLY —WOOD DECK
SCALE: 1 /4" = 1 '-0"
D ROOF AND EXISTING ROOF TRUSS
ORY TRUSS WORK, MATCH EXISTING ROOF
—WOOD DECK, HEIL HEIGHT VIF.
S-4 VERIFY EXISTING EPICORE FLOOR
)OF TO ENTIRE DECK
EERED TRUSS SHOP DRAWINGS
2"x8" P.T.
STRINGER
INSTALL PL 400 GLUE ALL SIDES
TYP AS REQUIRED V.I.F.
2"x8" P.T.
° STRINGER
2"x8"x 5' P.T. °
RINGER SPLICE
ZEWED WITH 2-1/2" "LEDDERLOCK"
i" OC STAGGERED TYP.
VGER REPAIR DETAIL (AS R
TOP OF
BEAM -
OUCIM. w.1.0.
THIS ROOF FRAMING PLAN SHOWS LOCATION
AND DIRECTIONS OF ALL ROOF MEMBERS
(TRUSSES AND GIRDERS). FOR INDIVIDUAL
TRUSSES, SEE LAYOUT AND ENGINEERING
SHEETS BY TRUSS MANUFACTURER,
VOTE:
VOTE FUTURE A/C WORK WILL REQUIRE ABOVE
NTTIC ACCESS IN CEILING PROVIDED BY
ONTRACTOR VIF NEW ATTIC HATCH LOCATION
MATCH PLYWOOD ADD NEW 2X6 CAT MEMBERS
TO EXISTING PLYWOOD, VERIFY DECK LEVEL TYP.
VERIFY IN FIELD ALL CONDTIONS
NO TRUSS WORK TO EXISTING ROOF
MATCH EXISTING PLY —WOOD DECK
SEE WALL SECTIONS S-4
INSTALL NEW ROOF TO ENTIRE DECK
VERIFY IN FIELD
EXISTING TIE BEAM
VERIFY IN FIELD
29'-6"
VERIFY IN FIELD
NEW 4" TUBE 56 KSI
STEEL COLUMN
po o o 0rA 0
0 16'
SPEC NEW V'
EPDXY ANCHOR BOLTS
3/4" DIA SIMPSION TYP.
TI
n NEW 4" TUBE 56 KSI
S EL COLUMN
a W 1/4' BASE PLATE
16'
O
SPEC NEW 4"
EPDXY ANCHOR BOLTS
3/4" DIA SIMPSION 7-
TYP.
4 8w 4 8„v
BEAM BEAM
O BASE PLATE USE SIMPSION MTS 18 TWIST
Scale: N.T.S. STRAPS EACH COL (2) TWO CITY
NEW 4!' TUBE 56 KSI
ANCHOR SSLEAVE SEE T-1
NEW 4" TUBE 56 KSI
STEEL COLUMN
W/ 1/4' BASE PLATE
TYP.
EXISTING COL —TIE BEAM
VERIFY IN FIELD
NEW COLUMN DETAIL
Scale: N.T.S.
NEW 4' TUBE 56 KSI
S EL COLUMN
W 1/4' BASE PLATE
TYP.
NEW 56 KSI STEEL COL
W/ 1/4" BASE PLATE
-
WALL LEGEND
EXISTING 8" WALL 8"
TO REMAIN
NO WORK
NEW 6" WALL 6"
U.L.
1 HOUR U.L. RATED
NEW 8" BLOCK WALL W/ 8" CELL
FILLED CELL 4000 PSI
M 5 BAR EACH CELL
NEW 6" R-19 WALL
2X6 WALL 12" O.C.
NEW 4" WALL
W/ 5/8" DRYWALL
NEW 6" OR 4" WALL
W/ 5/8" DRYWALL
WOOD POCKET DOOR
2'-8" POCKET
4" NEW
EXISTING 8" CMU FILLED CELL FT-18" CELL
NEW 56 KSI STEEL COL o o
W 1/4" BASE PLATE
S�E 6ETAILS THIS PAGE °
0
BEAM LEGEND
2X6 SYP-1 WOOD TRUSS 24" OC TYP.
INSTALL ON TOP OF EXISTING TIE BEAM
ON TOP OF DOUBLE 2X6 TOP PLATE 12"O.C.
SEE WALL SECTION S-4
ANCHOR SCHEDULE
8
USE "SIMPSION GALV STEEL ANCHOR FOR G-1
FOLLOW ALL MFR. INSTALLATION REQ.'S
USE "SIMPSION MTS 18" TWIST WOOD STRAP
TRUSS A-1
NOTE USE (2) TWO QTY AT EACH COLUMN TYP.
TOP 2XATE
USE "SIMPSION 2X6 U—STRAP WOOD STRAP TYP
USE "SIMPSION MTS 18" TWIST WOOD STRAP
A-2
FOLLOW ALL MFR. INSTALLATION REQ.'S
USE "SIMPSION MTS 18" TWIST WOOD STRAP
A-3
FOLLOW ALL MFR. INSTALLATION REQ.'S
USE "SIMPSION MTSAM 24" FLAT WOOD STRAP
F-1
FOLLOW ALL MFR. INSTALLATION REQ.'S
USE "SIMPSION MTSAM 24" FLAT WOOD STRAP
G
FOLLOW ALL MFR. INSTALLATION REQ.'S
NOTE: ALL
TO BE (2)
OTHERWISE
HEADERS &
2X12 SYP
NOTED ON
WOOD BEAMS
#2 UNLESS
PLAN
STING COL —TIE BEAM
VERIFY IN FIELD
ALTERATION GENERAL NOTES:
1 REMOVAL OF THE EXISTING IMPROVEMENTS SHALL BE AS REQUIRED FOR
THE PROJECT. THE MATERIALS REMOVED FROM THE SITE SHALL BE DISPOSED
OF IN A PROPER AND LEGAL MANNER PER FEDERAL, STATE, AND OR LOCAL
LAWS AND ORDINANCES.
2 EXISTING BUILDING ADDITIONS, WALLS FLOORS CEILINGS ELECTRICAL PIPES
STRUCTURES, TO REMAIN SHALL BE PROTECTED FROM DAMAGE BY THE
CONTRACTOR, ANY DAMAGE DURING CONSTRUCTION SHALL BE RESTORED,
RECONSTRUCTED OR REPLACED BY THE CONTRACTOR AT HIS EXPENSE. ALL
DAMAGES SHALL BE RESTORED OR REPLACED TO AT LEAST THEIR ORIGINAL
CONDITION OR AS REQUIRED OR DICTATED BY FEDERAL, STATE, COUNTY,
CITY OR LOCAL GOVERNING AGENCIES. ANY UTILITIES REQUIRED TO REMAIN
IN SERVICE FOR EXISTING BUILDING ADDITIONS TO REMAIN SHALL BE
PROTECTED.
3 IT IS THE RESPOSIBILITY OF THE CONTRACTOR TO INSPECT EACH DAY AND
REMOVE ALL MUD, DIRT, GRAVEL AND LOOSE MATERIALS TRACKED, DUMPED,
SPILLED OR WIND BLOWN FROM THIS SITE ONTO OTHER SITES, RIGHT OF
WAYS, PUBLIC OR PRIVATE STREETS OR ROADS, DRIVEWAYS, YARDS OR
SIDEWALKS. THE CONTRACTOR MUST CLEAN OR PICK UP DAILY IF
NECESSARY.
4 IT IS THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE OWNER AND ALL
THE UTILITY COMPANIES AND DEPARTMENTS. VERIFY THAT UTILITIES HAVE
BEEN DISCONNECTED AND CAPPED BEFORE STARTING DEMOUT10N
OPERATIONS.
5 IT IS THE RESPONSIBILITY OF THE CONTRACTORS TO OBTAIN ALL FEDERAL,
STATE, COUNTY, CITY, AND LOCAL PERMITS FOR ANY AND ALL WORK
REQUIRED UNLESS OTHERWISE NOTED. THIS SHALL INCLUDE ALL SUBMITTALS
AS REQUIRED INCLUDING STORMWATER RUNOFF CONTROL. THE CONTRACTOR
OR CONTRACTORS ARE RESPONSIBLE TO PAY FOR ALL REQUIRED PERMITS
BY ANY OR ALL AGENCIES MENTIONED ABOVE UNLESS OTHERWISE NOTED BY
THE CONTRACTOR OR SPECIFICATIONS.
6 THE CONTRACTOR MUST VISIT THE SITE AND STUDY EXISTING PHYSICAL
BUILDING CONDITIONS, REVIEW EXISTING DRAWINGS, AND REACH THEIR OWN
CONCLUSIONS ON WORK NECESSARY TO ACCOMPLISH INTENDED RESULTS
DESCRIBED BY THE PROJECT DOCUMENTS.
7 ALL PIPES AND CONDUITS IN WALLS THAT ARE TO BE DEMOLISHED ARE
TO BE REMOVED AND/OR RELOCATED AS REQUIRED.
8 JOBSITE INSPECTION MUST BE CONDUCTED TO EXAMINE EXISTING ROOF
WALL, CONDITIONS, TO DETERMINE NATURE AND SCOPE OF WORK OR ANY
DIFFICULTIES THAT MIGHT ARISE AT TIME OF WORK. IN ADDITION, EXAMINE
ALL WORK THAT IS INTENDED TO REMAIN AS PART OF THE COMPLETED
PROJECT AND REPORT ALL UNSATISFACTORY CONDITIONS TO OWNER PRIOR
TO COMMENCEMENT OF WORK. EXERCISE EXTREME CARE DURING DEMOLITION
SO AS NOT TO DAMAGE CONSTRUCTION AND OTHER STRUCTURES THAT ARE
INTENDED TO REMAIN. ANYTHING DAMAGED AT TIME OF WORK IS TO BE
REPAIRED AND/OR REPLACED TO MATCH EXISTING CONSTRUCTION AT
CONTRACTORS EXPENSE.
COMMENCE
9 UTILITY SERVICE: MAINTAIN EXISTING UTILITIES INDICATED TO REMAIN IN
SERVICE AND PROTECT THEM AGAINST DAMAGE DURING SELECTIVE
DEMOLITION OPERATIONS.
10 ALL EXISTING SERVICES, MECHANICAL, ELECTRICAL, AND PLUMBING, SHALL
REMAIN IN CONTINUOUS OPERATION THROUGHOUT THE ENTIRE CONSTRUCTION
PROCESS. IF IT BECOMES NECESSARY TO SHUT DOWN ANY OF THESE
SERVICES, THE OWNER SHALL BE NOTIFIED, AS IDENTIFIED IN THE
SPECIFICATIONS, BY THE CONTRACTOR.
11 GENERAL CONTRACTOR SHALL COORDINATE AND OBTAIN ALL PERMITS
REQUIRED TO COMPLETE THE CONSTRUCTION OF THE WORK AS
INDICATED ON THE TRUSS DRAWINGS.
12. GENERAL CONTRACTOR SHALL INCLUDE IN THE BASE BID ALL FEES
ASSOCIATED WITH THE CONSTRUCTION OF THIS PROJECT, INCLUDING
BUT NOT LIMITED TO PERMIT FEES, DUMP FEES, SUBCONTRACTOR
PERMIT FEES, DEMO AND IMPACT FEES.
13. IF DISSIMILAR METALS ARE TO BE JOINED, ENGINEER APPROVED
INSULA11ON UNIONS MUST BE APPROVED.
NOTE: ADDITIONALTERATION
F.B.C. 7th ED. 2020 EXISTING BUILDING (section 602,603,604)
ADDITION: AN EXTENSION OR INCREASE IN FLOOR AREA, NUMBER OF STORIES
OR HEIGHT OF A BUILDING OR STRUCTURE.
ALTERATION: ANY CONSTRUCTION OR RENOVATION TO AN EXISTING
STRUCTURE OTHER THAN REPAIR OR ADDITION. ALTERATIONS ARE CLASSIFIED
AS LEVEL 1, LEVEL 2, LEVEL 3.
THIS PROJECT IS CLASSIFIED AS ADDITION. LEVEL 1
NOTE:
Contractor is responsible for bracing of structure during
construction.
All measurements to be verified by contractor prior to start
of job.
All hardware to be stainless steel ONLY
NOTE:
THESE PLANS AND ALL ASSOCIATED DOCUMENTS ARE VALID FOR REPAIR
CONSTRUCTION ONLY UPON STAMPED APPROVAL FROM APPROPRIATE
GOVERNING JURISDICTION, THESE PLANS ARE VOID AND SHALL NOT BE
USED FOR CONSTRUCTION OR ANY OTHER PURPOSE WITHOUT THE
CITY OF STUART BUILDING DEPARTMENT REVIEW AND APPROVAL.
N 01)
O
2
�
oCO
oo
00 0
00 04w
a
N N
gin
11
04 04
°
(( �
0z
O rn
z14-
V
Ld M
X_
lv�L
0 �
w
N (n
o a
cw
U
W 'Q
�<
>a
U
"o
�G
,a
w
m'
Z
m a
�
a
zr--�
�1'
Z
1D
E
,
W
U O
O�
NN
Q
�no
o
F�1
w
a
0 a z
rr
W
`"
o
W
�oz
z C
U
zQo
a
o
wow
<w
E--i
N
w�a
C�6WU)
" u
w_
0
:m� L
Q a
,^
L J
a
uGa
�cz
'mow
T__q
ao,
w=n:
>a�
moo'
v, z
wa
U -U
Lwm
aza
a
U S w
ao<^
WILLIAM J. MATHERS, PE
~ a a FL # 19658
owa
0
o >>.
a r _
9658 . fz
ce
tf
zoo ✓ 'e:G y,a�'�j/ p�pL��'%/�./.
z
Uw
ami
Mwo
o�w
DRAWN
J.V.H.
CHECKED
W.J.M.
DATE
OCT 21 2021
SCALE
AS NOTED
JOB NO.
2021-BROWN
SHEET
T-1
PLUMBING NOTES:
1. Domestic water piping shall be copper with wrought copper fittings. Close with a
non -lead bearing solder. Insulate hot water piping with a minimum of 1" fiberglass
insulation.
2. The owner shall select all plumbing fixtures and trim.
3. Plumbing contractor shall provide complete condensate system including 2" deep
emergency drain pan under air handler for A/C system. Coordinate work with A/C
contractor.
4. All vent, waste, and condensate lines shall be concealed in walls or under floor slab.
5. All water piping shall be type "L" copper. Vent and waste may be PVC where
allowed by Florida Building code.
6. All plumbing fixtures shall have air chambers, and floor drains shall have trap
primers.
7. Drawings are diagrammatic. Do not scale drawings for exact locations of equipment,
piping, fixtures, etc.
B. Contractor shall visit the job site and thoroughly familiarize himself with all existing
conditions.
9. All required insurance shall be provided for protection against public liability or
property damage for the duration of the work.
10. Verify location, size, and elevation for all existing utilities prior to beginning
construction. Advice engineer of any discrepancies.
11. All materials shall be new as Shown.
12. All work shall be performed by a licensed plumbing contractor in a first class
workmanlike manner. The completed system shall be fully operative and acceptance
by owner must be a condition of the contract.
13. Soil, waste, and vent piping to be PVC schedule 40 DWV. Waste and vent piping
above slab shall be PVC if approved by local authorities having jurisdiction.
14. All work shall be coordinated with other trades to avoid interference with the
progress of construction.
15. All fixtures must be provided with readily available stops.
16. If dissimilar metals are to be joined approved insulation unions must be approved.
17. Any slab cuts and repair shall be by general contractor and included in his bid.
18. All fixtures shall be projected against water hammer with air chambers or shock
absorbers as indicated on the plans.
19. Provide fully accessible cleanouts or sanitary and waste piping at every change of
direction and at bottom of stacks.
20. Vent lines to extend 6" minimum above roof and flash with lead or connect to
existing vent system.
GENERAL NOTES:
1. THE STRUCTURE IS DESIGNED TO BE SELF-SUPPORTING AND STABLE AFTER THE BUILDING
IS FULLY COMPLETED. IT IS SOLELY THE PLUMBING CONTRACTOR'S RESPONSIBILITY TO
DETERMINE ERECTION PROCEDURE AND SEQUENCE AND TO INSURE THE SAFETY OF THE
BUILDING AND ITS COMPONENT PARTS DURING ERECTION. THIS INCLUDES THE ADDITION
OF WHATEVER SHORING, SHEETING, TEMPORARY BRACING, GUYS CONC. SLEAVES TIEDOWNS
WHICH MIGHT BE NECESSARY.
2. IT IS SOLELY THE CONTRACTOR'S RESPONSIBILITY TO FOLLOW ALL OSHA APPLICABLE
SAFETY CODES AND REGULATIONS DURING ALL PHASES OF CONSTRUCTION.
3. SHOULD ANY OF THE DETAILED INSTRUCTIONS SHOWN ON THE PLANS CONFLICT WITH THE
GENERAL STRUCTURAL NOTES, THE SPECIFICATIONS OR WITH EACH OTHER, THE STRICTEST
PROVISION SHALL GOVERN.
4, THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL DIMENSIONS AND
ELEVATIONS SHOWN ON THE PLANS AND FOR COORDINATING ALL DIMENSIONS AND
ELEVATIONS SHOWN ON THE ENGINEERING DRAWINGS. IF DISCREPANCIES IN THE
DIMENSIONS OCCUR, IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO BRING THE
DISCREPANCY TO THE ATTENTION OF THE ENGINEER BEFORE PROCEEDING WITH THE
WORK.
5. Contractor shall ANCHOR "ALL HOT & COLD WATER LINES ELBOWS AND VALVES"
TO PREVENT "WATER HAMMER" TYPICAL
6. All construction must meet the latest edtion, Florida Accessibility Code
Requirements and the A.D.A. barrier free requirements. Latest edition
7. General Contractor shall coordinate and install all necessary backing supports for
walls plumbing/lighting fixtures, Grab Bars, Hooks etc.
8. Contractor shall verify final selection of all finishes with Owner
before proceeding with any work.
g. All work shall be performed in accordance with the codes and/or regulations of
ALL COUNTY, State of Florida, and all other codes, and/or
regulations by any other authorities having jurisdiction over the work.
10. Contractor shall make no changes without written approval from the Engineer
11. Contractor shall INSULATE "ALL HOT WATER LINES ELBOWS AND VALVES" FROM
ALL NEW H.W.H. SUPPLY TYPICAL
A
PROVIDE NEW S'DRAIN
CLEAN OUT FOR NEW
SINKS D.W. UNIT
PROVIDE NEW 1/2"
HOT & COLD WATER
SUPPLY LINES TO NEW
SINK/D.W.
PROVIDE NEW 1/2"HOT
COLD WATER SUPPLY
LINE TO NEW SINK -
VERIFY EXISTING OPENING
ENCLOSED PORCH
9'-.4" CEIL.
28'-8"
VERIFY INSIDE DIM.
LIVING ROOM
VAULT CEIL.
STRUCTURAL_ BEAM ABOVE TO REMAIN
FOYER
VAULT CEIL: CNEW
PROVIDE NEW
DRAIN LINES
SINKS
PROVIDE NEW 1/2"
COLD WATER SUPPLY
LINE TO NEW W.C.
EXISTING GROUND FL. A/C
SYSTEM, WALLS TO BE REMOVED
UNDER SEPARATE A/C PERMIT
VERIFY/CAP ALL EXISTING
DRAIN LINES
VERIFY IN FIELD
T.
CL
T. 6X6
NEW
2
PROVIDE NEW 1/2"
HOT & COLD WATER
SUPPLY LINES TO NEW
z
NEW
SINK.
SINK
BATH
N
9'-0" CELL.
F z„
SINK & W.C. LOCATION
VERIFY FLOOR SLAB
7
TUB
II
PROVIDE NEW 1/2" w
COLD WATER SUPPLY HALL o r
KITCHEN LINE TO NEW ICE. g'_0" CELL. a
2 BOWL 9'-0" VERIFY CEIL �� BATH
SINK o� s'-o" CEIL.
NEW �� oo" iv NEI
� = NE1
SINK
I o
Ilo
4"STEP
NEW
Uj
71
13'
4"
6"
3'-4 11' 7"
ERIFY FIE D
INSTALL NEW
1 HOUR 6' UL
CPHINET / HUTCH
SEE Sll) DWG
FIRE RATED 14'-10"
NEW GARAGE
5'-4'
CABINET / HUTCH
SEE SHOP DWG
PROVIDE NEW 1/2"'
HOT & COLD WATER
SUPPLY LINES TO NEW
O
WASHER NOTE:
o
VERIFY IN FIELD
z_
3
INSTALL NEW CUSTOM
HUTCH
SEE SHOP DWG
ly
BK
NOOK
W-O" CEIL.
1 CAR GARAGE
9'-0" VERIFY CEIL.
EXISHNG
MiL000R ,t
NEW 170 D ZONE GARAGE DOOR
12'-0
NEW MASONARY OPENING
W.C.
DRAIN LINE FROM 2ND FLOOR THRU NEW ROOF
TO EXISTING DRAIN LINES 3" V.T.R:
VERIFY IN FIELD
SEE SHEET P-2 \
UPPER FLOOR l n
RELOCATE / REMOVE
EXISTING 3" P.V.C. DRAIN
LINE VERIFY LOCATION
FROM 2ND FLOOR
VERIFY/ CUT FLOOR
SLAB AS REQUIRED FOR
NEW DRAIN LOCATION
CAP ALL EXISTING DRAIN
PIPES TYP.
REMOVE EXISTING SINKS,
VERIFY LOCATION
REPAIR FLOOR SLAB
CAP ALL PIPES TYP.
REMOVE 2"DRAIN LINE
VERIFY LOCATION
VERIFY FLOOR SLAB
CAP ALL EXISTING PIPES
FOR TUB REMOVED
PROVIDE NEW 1/2"
HOT & COLD WATER
SUPPLY LINES TO NEW
SINK -
PROVIDE NEW 1/2"
COLD WATER SUPPLY
LINE TO NEW W.C.
INSTALL NEW ELEC TANKLESS
ON DEMAND ELEC W.H. SEE P-1
EXISTING 200 AMP PANEL
REMOVE EXISTING W.H.
NOTE: EXISTING SUPPLY
LINES TO REMAIN
SCALE.114! - T-0'
3,> THRU NEW ROOF
3" V.T.R.
EXISTING
3"
4" C.O.
4
THRU NEW ROOF
3" V.T.R.
THRU NEW ROOF
3" V.T.R.
3"
3"
LAV.
3„ LAV.
3„
SINK VERIFY
THRU ROOF
W.C.
3" V.T.R.
3"
4 SINK
4 W.C.
NEW / EXISTING PLUMBING
SYSTEM GROUND FLOOR
u 3„
y4" C.O.
WASHER
SINK
4 <4�
TO EXISTING COUNTY DRAIN
VERIFY IN FIELD
PLUMBING RISER DIAGRAM
LOWER LEVEL PLAN N.T.S.
LIVING:
2,695
SF
GARAGE:
300
SF
COVERED PORCH:
275
SF
COVERED ENTRY:
25
SF
TOTAL:
3,295
SF
TOTAL A/C 2,970 S.F.
WOOD NOTE: ALL WOOD IN CONTACT WITH THE
DECK METAL OR PLASTIC THAT SUPPORTS
PERMANENT STRUCTURES INTENDED FOR HUMAN
OCCUPANCY SHALL BE APPROVED PRESSURE
TREATED WOOD ALL REPLACED WOOD SHALL BE
P.T. SUITABLE FOR CONTACT USE. THIS IS IN
COMPLIANCE PER 2020 FLORIDA BUILDING CODE
7TH EDITION REF. DISSIMILAR MATERIALS
CONTACT.
NOTE: 1. SEE AMERICAN STANDARD SPEC'S FOR MANUFACTURERS NUMBERS
FOR TOILET ACCESSORIES.
2. ALL TOILET PAR71TIONS SHOWERS DIMENSIONS ARE CENTER LINE
OF PARTITION. (WHEN USED)
3. CONTRACTOR TO USE PLYWOOD BACKING BOARD FOR ALL NEW
GRAB BARS, SHELVES & ACCESSORIES TYPICAL VIE
NOTE:
Contractor is responsible for bracing of PLUMBING Structure during
construction.
All measurements to be verified by contractor prior to start
of job.
All Hardware, SINKS FIXTURES CHOSEN BY OWNER
NOTE:
THESE PLANS AND ALL ASSOCIATED DOCUMENTS ARE VALID FOR CONSTRUCTION
ONLY UPON STAMPED APPROVAL FROM APPROPRIATE GOVERNING JURISDICTION.
THESE PLANS ARE VOID AND SHALL NOT BE USED FOR CONSTRUCTION OR ANY
OTHER PURPOSE WITHOUT BUILDING DEPARTMENT REVIEW AND APPROVAL.
w
a
Fa
oLL
00
�a
o=
U�-
0
o�
aw
w U
a�
�w
o ,n
ow
U�
w�
m�
w
o�
z�
W
�z
a-
F
00
z�
as
ww
a�
or
mz N a O
0o O c
3a I o
�0 00
q) w
a o N 0 p
z
oz y 0
iw
N
w
m� z
o= O
a OL
o
zo �
a
z4 r X
3 Q�
0)
�o O �
N o = d�-
F� wM
ow X J o
�z o�
aw wF
rn �
Q %
o M
zs NV)
w
00
N
a�
w�
U w
o�
�z
a�
I�
�o
zw
w
a�
oa
ow
Wa
w DI m a 1-.
g N / 7
56 r�
UO ® �1
on
a�
Foo M r,
UI O Z F-+-I
o� Z
a
w �
W g
wog N
zao
pro
zrr ^y
air w
oz
wa
g<�
>�o
r« a
rya
ooa
woz
ao LO1^
wzz
U>a3 u✓
N �
wz>
0
rya
U U
<Zm
aza
oa
x
JUI
m
d U U
QWILLIAM J. MATHERS, PE
FL # 19658
FZo
F T U
�ma
Fain #
w o TATE OF
,o
O k ,`
zoo •
.c '
a wo // � •i.
w i RAT ONLY
�zw
U
aW
U
U - w
a m I
' W O
O S
o`o
uww
p-U
W F
o
Z '
�0gw
so
awe
0 0Q
Vow
H J d
�LL W
�wg
W�a
w
aW
Qzz
uo
zz
Ows U
Z I- a
DRAWN
J.V.H.
CHECKED
W.J.M.
DATE
DEC 2021
SCALE
AS NOTED
JOB NO.
2021-BROWN
SHEET
P - I
PLUMBING PLAN UPPER LEVEL NEW
PROVIDE NEW 1/2"
HOT & COLD WATER
SUPPLY LINE TO NEW
SINK
PROVIDE NEW 2" PVC
DRAIN LINES FOR NEW
SINKS
PROVIDE NEW 3"drain &
CLEAN OUT FOR NEW
SHOWER DRAIN
PROVIDE NEW 1/2"
HOT & COLD WATER
SUPPLY LINE TO NEW
SHOWER
PROVIDE NEW 1/2" COLD
WATER SUPPLY LINE TO
NEW LAV.
PROVIDE NEW 3" PVC
DRAIN LINES FOR NEW
W.C.
SCALE-1/4' = T-0'
THRU NEW ROOF
THRU NEW ROOF
3" V.T.R.
W ROOF
TO EXISTING DRAIN system
VERIFY IN FIELD
SEE P-1 FOR LOWER LEVEL RISER
PLUMBING RISER DIAGRAM
UPPER FLOOR NEW N.T.S.
WOOD NOTE: ALL WOOD IN CONTACT WITH THE
DECK METAL OR PLASTIC THAT SUPPORTS
PERMANENT STRUCTURES INTENDED FOR HUMAN
OCCUPANCY SHALL BE APPROVED PRESSURE
TREATED WOOD ALL REPLACED WOOD SHALL BE
P.T. SUITABLE FOR CONTACT USE. THIS IS IN
COMPLIANCE PER 2020 FLORIDA BUILDING CODE
7TH EDITION REF. DISSIMILAR MATERIALS
CONTACT.
NOTE: 1. SEE AMERICAN STANDARD SPEC'S FOR MANUFACTURERS NUMBERS
FOR TOILET ACCESSORIES.
2. ALL TOILET PARTITIONS SHOWERS DIMENSIONS ARE CENTER LINE
OF PARTITION. (WHEN USED)
3. CONTRACTOR TO USE PLYWOOD BACKING BOARD FOR ALL NEW
GRAB BARS, SHELVES & ACCESSORIES TYPICAL VIF.
NOTE:
Contractor is responsible for bracing of PLUMBING Structure during
construction.
All measurements to be verified by contractor prior to start
of job.
All hardware CHOSEN BY OWNER
NOTE:
THESE PLANS AND ALL ASSOCIATED DOCUMENTS ARE VALID FOR CONSTRUCTION
ONLY UPON STAMPED APPROVAL FROM APPROPRIATE GOVERNING JURISDICTION.
THESE PLANS ARE VOID AND SHALL NOT BE USED FOR CONSTRUCTION OR ANY
OTHER PURPOSE WITHOUT BUILDING DEPARTMENT REVIEW AND APPROVAL.
r�
w
0
Fa
�o
ou
rw
<w
ow
zc
cLL
z
CL 1 J
w U
mm
o�
o�
�o
�w
w`
mw
o�
z�
w
�z
x-
xw
mx
00
zw
a' -
a
ww
rc
}U
ww
c c
Qw
z:
a�
}
m
�z
W�
�a
oz
0
wn
cc
Qo
0
00
z_
a
cw
oz
Tw z
�w
m�
W
W�
a�
0
�o
z
�z
zw
wo
�a
z
az
xQ
00
Fd _w
jo
0
�w
W?
oz
NW
zz
a
aw
IN
I
ow
}=
�4
z�
ow
C6o
w
�o
r_-
w�
zw
oa
U Z
Q�
13
�o
rW
�f
a�
ox
U W
N
Lo
O
O
I
a
o
00
W
ire
N
N
a
r
�
O
z
2
Z
v
D
o
�
}
S m
10
W M
X
�
V
Ld
0
� U
V7
(1)
FT-4
W
11L.W����
Y
Z
r1
W
z
I
a
W
a
0
0
rFr�
FT-1
WILLIAM J. MATHERS, PE
FL'# 19658,'
t:
DRAWN
J.V.H.
CHECKED
W.J.M.
DATE
OCT 2021
SCALE
AS NOTED
JOB NO.
2021— BROWN
SHEET
P 2
W
ELECTRICAL NOTES:
Electrical Contractor shall supply and install all new
electrical work indicated. Construction shall be in
accordance
1. with drawings and applicable specifications. If a
problem is encountered in complying with this
requirement, contractor shall notify the owner or his
representative as soon as possible after discovery of the
problem and shall not proceed with that portion of the
work until owner has directed corrective action to be
taken.
2. Electrical contractor shall visit job site and
familiarize himself with all conditions affecting electrical
and communications installation and make provisions as
to the cost thereof. Existing conditions of electrical
equipment, light fixtures, etc. that are part of the final
system shall be verified by the contractor prior to
submitting his bid. FLORIDA BUILDING CODE 2020 7th
EDITION Ordinances of the authority having jurisdiction.
3. Do not scale the electrical drawings.
4. Refer to FLOOR plans and elevations for exact location
of all equipment. Confirm with owner's representative.
5. Minimum wire size shall be # 12 A.W.G. excluding
control wiring. Unless otherwise noted, all conductors
shall be copper with THHN insulation.
6. Outlet boxes shall be pressed steel in dry locations,
cast alloy with threaded hubs in wet or damp locations
and special enclosures for all other classified areas.
7. It is not the intent of these plans to show every
minor detail of construction. The contractor is expected
to furnish All work shall be performed in accordance with
the latest edition of the National Electrical Code and
Florida Building codes and placed in proper working order.
8. Electrical system shall be complete and effectively
grounded as required by the latest edition of the NEC or
local codes. All equipment shall be new and bear
Underwriters labels where applicable, unless noted
otherwise.
9.AII work shall be performed by a licensed electrical
contractor in a first class workmanlike manner.
10.The completed system shall be fully operative and
accepted by the Engineer All work shall be coordinated
with other trades to avoid interference with the progress
of construction.
11. Provide and install all items for a complete electrical
system and provide all trim, accessory requirements
necessary for equipment to be operational.
12. Contractor shall guarantee all new materials and
workmanship free from defects for a period of not less
than (1) one year from date of acceptance.
13. Correction of cry defects shall be completed
without additional charge and shall include replacement
or repair of any other phase of the insulation which may
have been damaged thereby.
14. All required insurance shall be provided for
protection against public liability and property damage
for the duration of the work.
15. Contractor shall pay for all permits, fees,
inspections and testing. Contractor to obtain permit and
approved submittals prior to beginning work or ordering
equipment. 16. The electrical installation shall meet all
standard requirements of power and telephone
companies.
17. Contractor shall coordinate with mechanical drawings
and provide all necessary ELEVATOR control wiring.
1& All circuit breakers feeding mechanical equipment
shall be HACR type circuit breakers.
19. Provide and install conduit, conductors, pull wires,
cover plates, devices, etc. for all outlets as indicated.
20. Materials, products, and equipment, including all
components thereof, shall be new and such as appear on
the UL list of approved items and shall meet or exceed
the requirements of NEC, NEMA, and IECE latest editions.
21 Contractor shall submit drawings or cut sheets of
lighting fixtures, switches, and other electrical items for
approval BY OWNER
22. Contractor shall be responsible for all cutting and
patching required of his work.
23. Electrical contractor shall label all panels with
typewritten directories
24. All light switches to be at 42" AFF.
25. All electrical wiring shall be the responsibility of the
electrical contractor. All electrical wiring for the HVAC
system including controls, thermostats, power, etc. shall
be the responsibility of the electrical contractor.
26. Panelboards: All current carrying buses shall be
copper. All ground bus bars shall be copper.
Panelboard enclosures shall be furnished without
pre -punched concentric holes. A.I.C. ratings shall be as
indicated on panelboard schedules.
27. Disconnect switches shall be H.P. rated, heavy duty,
quick -make, quick -break enclosures as required by
exposure.
28. Motor starters shall be manual or magnetic, with
overload relays in each hot leg.
29. Contractor shall confirm with FPL any and all
requirements such as: lug size restrictions, conduit
entry, transformer size, scheduled down time for owners
confirmation, etc. Any conflicts shall be brought to
attention of the engineer before proceeding with any
work. 30. ALL EXTERIOR OUTLETS AND NEW OUTLETS IN
THE EXISTING GARAGE, KITCHEN AND BATHROOMS AND
ALL EXTERIOR LIGHTS, OUTLETS ARE TO BE GFI
PROTECTED. W/ ARC -FAULT CIRCUIT INTERRUPTION
PROTECTION TYP.
AR M
i\
r MASTER SUITE
" CEIL 9 - L
AR
\ / l
A
AR (C9 SD
CUSTON SHELF SYSTEM Gn
w°
M CLOSET SINK INK
IL HA
\ r \ r VAULT IL
M B H
VAULT CEIL.
i
36" S.C. / W
abr
O
CUSTON SHELF SYSTEM CLOSET o 3'-5 5' 3"
AR I
T�
OSET \
8'-4" CEIL.
0 VP
� SHO
1
DD
I TE:
VAT
UND RATE
EXISTING P IT
/ SPIRAL STAIR
EXISTING 36" AIUNG
TO REMAIN
VERIFY I r
r
OP N LOF
VAULTE CEIL
8•-4" 3EIL
\ AFI \
.U.
AHU ATTIC
♦r
Al
i
EXIST CLOSET I AR
A ACCESS
w C. LT.
„� aosEr
2668 WOOD
AR sD EXIST DOOR 1 1
/ A UNDRY N
/ \ CLOSET 5D INSTALL NEW i%4 STUD
STAG( WALLS W/ 5/S' DRYWALL
ED OOM 2 SD
-0" CEIL. \ r r
N
AH r m
w
a
BATH 8.
8'-0"
1V
� r:vp:�
An
EGRESS WINDOW EGRESS WINDOW
MA
m
C
5
EE
R PAD
'YPE,
ARATE
LD TYP.
LL NKLESS
EMAND
W.H. SEE
CIRCUIT
1,FS
POLE/BREAKER
LOAD
WIRE SIZE
1,3
A/C SYSTEM CONDENSER #1
2P/40A
(3.8
KW)
#8
2,4
A.H.U. / HEAT STRIP #1
2P/60A
(9.5
KW)
#6
5,7
A/C SYSTEM CONDENSER #2
2P/40A
(3.8
KW)
#8
6,8
A.H.U. / HEAT STRIP #2
2P/60A
(9.5
KW)
#6
9,11
RANGE
2P/50A
12.0
KW
#6
10,12
DRYER
2P/30A
5.0
KW
#10
13
MICROWAVE
1P/20A
1.2
KW
#12
14
WASHER -LAUNDRY
1P/20A
1.5
KW
#12
15
REFRIGERATOR
1P/20A
1.2
KW
#12
16
DISHWASHER
1 P/20A
1.0
KW
#12
17
DISPOSAL
1P/20A
0.7
KW
#12
18
SMALL APPLIANCES
1 P/20A
1.5
KW
#12
19
SMALL APPLIANCES
1P/20A
1.5
KW
#12
20
SMALL APPLIANCES
1 P/20A
1.5
KW
#12
GEN. LIGHTING, RECEPTACLES,
9.0
KW
-
(6) CEILING FANS ® .15 EA.
0.9
KW
-
21-33
(2) EXHAUST FANS 0 .8 EA.
1P/15A
2.4
KW
#14
(10) HI -HATS ® .07 EA.
1.0
KW
-
-
1.8
KW
-
ALARM SYSTEM
1.2
KW
-
34,35
SPARES
-
TOTAL
LOAD (WITHOUT HVAC)
42.4
KW
GENERAL
LIGHTING CALC. FOR 2790
S.F. x 3 WATTS/SQ. FT.
=
2900
6.0 KW
ELECTRICAL SERVICE CALCULATION (PER SECTION 220-30 N.E.C.)
A.H.U. / HEAT STRIP 0 100% = 19.0 KW
FIRST 10.0 KW ® 100% = 10.0 KW
REMAINDER ® 40% (33.4 x .40) = 33.4 KW ELEVATOR 20 AMP
TOTAL COMPUTED LOAD = 62.4 KW
KW'S x 1000 w = 260 AMPS PROVIDE 300 AMP SERVICE
240 VOLTS (3) #2/0 THHN-CU IN 3" CONDUIT
ELECTRICAL LEGEND
DUPLEX RECEPTACLE
GFI
GROUND FAULT INDICATOR
WP
/WATER PROOF
QUAD RECEPTACLE
&
230 VOLTS
®
SPECIAL OUTLET
-
SWITCH A
-0 4
4 WAY SWITCH
-� 3
3 WAY SWITCH
INCANDESCENT LIGHT
RECESSED LIGHT
\ / vp
VAPORI PROOF
S*ItHED OUTLET
i
RECESSED LIGHT
\ r
(EYEBALL)
Qi
FLOOR OUTLET
HOLLYWOOD-STYLE
o n cn24 STRIP LIGHTING
ELECTRIC
METER BY
0
FLORIDA
POWER &
LIGHT
300 AMP 1PH.
300 AMP
3W, 115/230V
METER
FLUSH MOUNTED
NEMA 1 W/ 300
AMP MAIN BREKER
TRANSFORMER
BY FLORIDA
POWER &
E L E C T RI C A
K
FLOOD LIGHTS
E]TV
TELEVISION OUTLET
PH
PHONE OUTLET
®
EXHAUST FAN
-� pg
POWER BUTTON
0000
RBELL CHIMES
c sD
SMOKE DETECTOR CLG. MOUNT
Carbon Detector combo
sD SMOKE DETECTOR WALL MOUNT
!� JUNCTION BOX
J CEILING FAN (OUTLET ONLY)
LJ U TRACK LIGHTING
F-� FLUORESCENT FIXTURE
OPTIONAL 31
AMP MAIN
DISCONNECT
NOTE:100 AMP
TO BE USED
FOR NEW
ADDITION
„A"
EXISTING
PANEL
(3) #2/0 THHN-CU
IN 2" CONDUIT
00 AMP
„B„
NEW
PANEL
#4 SOLID OR STRAND CU. GROUND
TO #5 REINFORCING BARSAT
FOUNDATION BASE
COLD WATER
PIPE
R I S E R D I A G R A M
N.T.S.
W
W
MW
w
E-1
co
Q
Z
Iwo
>
W
H
Z
C)
U
W
F4
W
W
o
V 1
��II
NN
46
rE-1LO
H
FJ--I
EC
.-I
W'bU
zF�
Q=z _
m
Leo
z�n
W�
U �
Paz
WOOD NOTE: ALL WOOD IN CONTACT WITH THE DECK METAL OR PLASTIC THAT m
SUPPORTS PERMANENT STRUCTURES INTENDED FOR HUMAN OCCUPANCY SHALL a
BE APPROVED PRESSURE TREATED WOOD ALL REPLACED WOOD SHALL BE
ELECTRICAL UPPER LEVEL PLAN ELECTRICAL PLAN LOWER LEVEL M
P.T. SUITABLE FOR CONTACT USE. THIS IS IN COMPLIANCE PER 2020 FLORIDA
SCALE 1/4 ® 1-0 SCALE: 1/4 - 1-O BUILDING CODE 7TH EDITION REF. DISSIMILAR MATERIALS CONTACT
f } ■ - f p E. .
NOTE:
o-�
mom
wza
THESE PLANS AND ALL ASSOCIATED DOCUMENTS ARE VALID FOR CONSTRUCTION
N ONLY UPON STAMPED APPROVAL FROM APPROPRIATE GOVERNING JURISDICTION.
THESE PLANS ARE VOID AND SHALL NOT BE USED FOR CONSTRUCTION OR ANY L
OTHER PURPOSE WITHOUT BUILDING DEPARTMENT REVIEW AND APPROVAL.
0
zW�
wwa
wog^
w
z�r
aL�
-w
zz
wo
O w
os<
zee
ELECTRICAL NOTE:
ALL EXTERIOR OUTLETS AND OUTLETS IN THE BASEMENT, GARAGE, KITCHEN AND BATHROOMS
ARE TO BE GFI PROTECTED.
ALL LIGHT SWITCHES THAT OPERATE LIGHTS THAT ILLUMINATE STAIR AREAS SHALL BE
ILLUMINATED LIGHT SWITCHES.
ALL OUTLETS INSTALLED IN KITCHEN ISLANDS SHALL BE INSTALLED PER NEC 210-52
ARC -FAULT CIRCUIT INTERRUPTION PROTECTION SHALL BE PROVIDED IN ALL BEDROOMS.
DRAWN
J.H.
CHECKED
J.H.
DATE
12/21/21
SCALE
AS NOTED
JOB NO.
2021 BROWN
SHEET
E-1