HomeMy WebLinkAboutConstruction Plana N M In N M 0 0 0 3 a `) 0 J v Cu C. w �I m c m 0 m GENERAL NOTES: 1. CONTRACTOR SHALL VERIFY ALL CONDITIONS AT THE BUILDING AND NOTIFY THE OWNER OF ANY DISCREPANCIES BEFORE PROCEEDING WITH ANY WORK. 2. CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR FABRICATION PROCESSES AND CONSTRUCTION TECHNIQUES (INCLUDING SCAFFOLDING, BRACING, SHORING, ERECTION, ETC.) FOR COORDINATION OF VARIOUS TRADES, FOR SAFE CONDITIONS ON THE JOB SITE, AND FOR COMPLETE COMPLIANCE WITH THE WILLIAM STEIGER OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 (OSHA). 3. DO NOT SCALE DRAWINGS. 4. CONTRACTOR SHALL THOROUGHLY FAMILIARIZE THEMSELF WITH THE DRAWINGS WHICH, IN TURN, MAY AFFECT THE COST OF THE PROPER COMPLETION OF THE WORK HEREIN SPECIFIED, AND CONTRACTOR SHALL INCLUDE EVERYTHING REQUISITE AND NECESSARY TO THE ENTIRE FINISHING OF THE WORK, NOT WITHSTANDING THAT EVERY ITEM NECESSARILY REQUIRED BY SUCH WORK IS NOT SPECIFICALLY MENTIONED OR SHOWN. CONTRACTOR SHALL FURNISH ALL LABOR AND MATERIAL NECESSARY FOR THE COMPLETION OF ALL WORK AND DEMOLITION HEREINAFTER DESCRIBED. 5. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE CODES AND/OR REGULATIONS OF ST LUCIE COUNTY, STATE OF FLORIDA, AND ALL OTHER CODES, AND/OR REGULATIONS BY ANY OTHER AUTHORITIES HAVING JURISDICTION OVER THE WORK. 6. PROTECT EXISTING ADJACENT BUILDING STRUCTURES, FLOOR DECK AND GROUNDS FROM ANY DAMAGE WHICH MAY OCCUR DURING PERFORMANCE OF ALL WORK. ANY DAMAGE TO EXISTING FACILITIES TO REMAIN WILL BE REPAIRED, REPLACED OR RESTORED TO THE ORIGINAL CONDITION AND TO SATISFACTION OF ENGINEER AT THE CONTRACTOR'S EXPENSE. 7. CONTRACTOR SHALL MAKE NO CHANGES WITHOUT WRITTEN APPROVAL FROM THE ENGINEER 8. GENERAL CONTRACTOR SHALL COORDINATE AND OBTAIN ALL PERMITS REQUIRED TO COMPLETE THE CONSTRUCTION OF THE WORK AS INDICATED ON THE DRAWINGS. 9. GENERAL CONTRACTOR SHALL INCLUDE IN THE BASE BID ALL FEES ASSOCIATED WITH THE CONSTRUCTION OF THIS PROJECT, INCLUDING BUT NOT LIMITED TO PERMIT FEES, DUMP FEES, SUB —CONTRACTOR PERMIT FEES, DEMO AND IMPACT FEES. 10. CONTRACTOR IS TO COORDINATE AND ORGANIZE THE CONSTRUCTION PROCESS AND COMPLETE SAME IN A MANNER WHICH LEAST IMPACTS THE ADJOINING COMMON AREAS, IN ORDER TO MINIMIZE INCONVENIENCE TO THE OWNER. 11. ALL NEW CONSTRUCTION MUST MEET FLORIDA ACCESSIBILITY CODE FOR BUILDING REQUIREMENTS LATEST EDITION, AND A.D.A. BARRIER FREE REQUIREMENTS. 12. CONTRACTOR SHALL VERIFY FINAL SELECTION OF ALL FINISHES WITH THE OWNER BEFORE PROCEEDING WITH ANY WORK. 13. DISSIMILAR METALS SEPARATION: WHEREVER DISSIMILAR METALS CONTACT EACH OTHER, AND ARE SEPARATED FURTHER ON THE BELOW SCALE THAN BY A SINGLE INTERMEDIATE METAL, THE CONTACTING SURFACES SHALL BE INSULATED FROM EACH OTHER BY A BITUMINOUS COATING, 15# ASPHALT SATURATED FELT OR OTHER ENGINEER APPROVED MEANS METALS ARRANGED IN ORDER OF GALVANIC ACTIVITY: ALUMINUM, ZINC, GALVANIZED IRON, TIN ON STEEL, LEAD (HARD), STAINLESS STEEL, COPPER, MONEL. 14. IF DISSIMILAR METALS ARE TO BE JOINED, ENGINEER APPROVED INSULATION UNIONS MUST BE APPROVED. LUMBER & CONSTRUCTION NOTES: NOTES AND SPECIFICATIONS: Any or all prints or duplications obtained from these plans are valid only if signed and sealed by a registered professional engineer representing Mothers Engineering engineer of record. All construction shall comply with Local, State, and National Codes. All manufactured items shall be applied or installed in accordance with manufacturer's specifications and recommendations. And LISTED NOA'S LUMBER: All lumber shall be Southern Yellow Pine or Western Red Cedar surfaced four sides. Southern Yellow Pine shall be treated with chromated copper arsenate (CCA) 0.40 LBS/CF of retention. Stringers, cross members, rails, wood post, nailers, and blocking shall be NO.2 or better in accordance with southern pine inspection bureau grading rules. All sizes as shown on plans. HARDWARE: All hardware shall be new stainless 316 grade steel, for all bolts AND ANCHOR CLIPS S.S. typical. 1. ALL CONCRETE WORK SHALL CONFORM TO THE BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE (ACI 318-19 PLUS UPDATES) & SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS (ACI 301-16 PLUS UPDATES) OF THE AMERICAN CONCRETE INSTITUTE. 2, FABRICATED IN ACCORDANCE WITH THE A.C.I. BUILDING CODE (LATEST EDITION) AND THE LATEST MANUAL OF STANDARD PRACTICE (A.C.I. 315). SHOP DRAWINGS OF ALL REINFORCING STEEL MUST BE APPROVED BY THE ENGINEER BEFORE FABRICATION. 3. CONCRETE SHALL BE A MIX DESIGNED TO SECURE A STRENGTH OF MIN 4000 PSI AT 28 DAYS FOR THE NEW WALL AND SLUMP SHALL BE A MINIMUM OF 3" AND A MAXIMUM OF 5". CONCRETE DURING AND IMMEDIATELY AFTER DEPOSITING, SHALL BE THOROUGHLY COMPACTED BY MEANS OF MECHANICAL VIBRATION. 4. CONTRACTOR SHALL MAKE NO CHANGES WITHOUT WRITTEN APPROVAL FROM THE ENGINEER OR OWNER. PRODUCT APPROVAL DATA: Product Model Manufacturer Evaluation Agency Product Approval FL / NOA Expiration Date Number OVERHEAD GARAGE Steel Pan Sectional Garage Door AMERICAN Building MIAMI—DADE County Approved NOA No: 20-0901.25 JULY 31, 2025 DOORS MODEL # 824 Products Company SWING DOORS Fiberglass Opaque Masonite Florida Product Approval FL# 8228—R7 December 31, 2022 Outswing Door International WINDOWS HR 7710 A ALUM. PGT MIAMI—DADE County Approved NOA No: 20-0406.04 AUG 23, 2023 HR PW HR OX TT WINDOWS PW 7720 A ALUM. PG MIAMI—DADE County Approved NOA No: 20-040.10 FEB 19, 2024 HR PW HR OX ITT WALL SIDING Fiber Cement Siding James Hardee Buildin ProductInc. , MIAMI—DADE County Approved NOA No: 20-0825-09 AUG 02, 2026 SOFFIT HARDIE SOFFIT PANEL James Hardie Inc. MIAMI—DADE County Approved NOA No: 20-0730.06 May 01, 2022 Building Product, PPG "FIRE PAINT" 20 MIN SOFFIT PAINT PPG N/A N/A N/A ICE & WATER SHIELD POLY GLASS USA INC POLY GLASS USA INC Florida Product Approval FL# 5259-R29 DEC 21, 2022 CEMENT ROOFING TILE BORAL VILLA 900 TILE BORAL ROOFING CO. MIAMI-DADE County Approved NOA No: 21-0712.03 SEPT 21, 2026 JURISDICTION: St lucie COUNTY, FL CODE: FLORIDA BUILDING CODE 2020 7th EDITION PROJECT ADDRESS: 155 PEPPER LANE JENSEN BEACH FL __ PROJECT NAME: __BROWN-ADDITION_- ENGINEER-MATHERS ENGINEERING CORPORATION_ BUILDING DESIGNED: ENCLOSED_ X __ OPEN_____ WIND SPEED (3 SECOND GUST): 160 MPH_____ 160 D MPH__ X _ ASCE CATEGORY: 2 (SINGLE FAMILY HOUSE)__X__ OTHER - EXPOSURE: D IMPORTANCE FACTOR: _ 1_O _ INTERNAL PRESSURE COEFFICIENT: t0_18 MEAN BUILDING HEIGHT_20.5 OVERHANG_ NIA___ ROOF PITCH-f 2_______ COMPONENTS & CLADDING WIND PRESSURES__I/A_-____ SHUTTERS: YES_o� _ NO__N/A IMPACT RESISTANT ASSEMBLY: YES_ -%-// NO - - _ - NOTE: Contractor is responsible for bracing of structure during ALL PHASES OF Construction. All measurements ARE to be verified by contractor prior to start of job. All NEW hardware to be Stainless Steel 316 GRADE ONLY NOTES: A. THE PROPOSED RENOVATIONS DO NOT STRUCTURALLY ALTER THE REMAINING EXISTING STRUCTURAL SYSTEMS AND A REQUIREMENT TO UPGRADE IT BY THIS PERMIT APPLICATION IS NOT WARRANTED. B. EXISTING BUILDING COMPONENTS AND ELEMENTS OUTSIDE THE REMOVATION AREA WILL NOT HAVE THEIR CURRENT WINDLOAD RESISTANT CAPACITY COMPROMISED BY THE PROPOSED NEW CONSTRUCTION C. APPROVAL OF THESE PLANS IN NO WAY RELIEVES THE CONTRACTOR OR BUILDER OF COMPLYING WITH ORDINANCES OF LOCAL, STATE, OR FEDERAL JURISDICTIONS. D. 2020 FLORIDA BUILDING CODE, 7TH EDITION CHAPTER (1) SECTION 104.11 ALTERNATIVE MATERIALS, DESIGN AND METHODS OF CONSTRUCTION AND EQUIPMENT. AND RESIDENTAL CHAPTER 3, SECTIONS R301.1.3 ENGINEERED DESIGN. E. CONTRACTOR TO LOCATE SEAMS FOR BEST USE OF MATERIALS. VERIFY IN FIELD ANY ADDITIONAL BLOCKING OR ADDITIONAL WOOD NEEDED. FOR THE BEST USE FOR THE PROPOSED NEW CONSTRUCTION AREA CALCULATIONS EXISTING LIVING: UPPER BR & BATH GARAGE: COVERED PORCH: COVERED ENTRY: TOTAL: 1,840 SF 855 SF (NEW) 300 SF 275 SF 25 SF 3,295 SF TOTAL A/C 2,970 S.F. SEE FLOOR PLAN SHEETS EXISTING RESIDENCE LOCATION OF 2ND STORY / ADDITION TO RESIDENCE INTERIOR REMODEL LOCATION OF GARAGE — REMODEL EXISTING RESIDENCE 144 PEPPER LANE REE PI: PPEF SITE LOCATION MAP 155 PEPPER LANE JENSEN BEACH FL NOTE: THE PROPOSED RENOVATIONS DO NOT STRUCTURALLY ALTER THE REMAINING EXISTING STRUCTURAL SYSTEMS AND A REQUIREMENT TO UPGRADE EXISTING WINDOWS BY THIS APPLICATION IS NOT WARRANTED, FOR THIS PERMIT. EXISTING BUILDINGS COMPONENTS AND ELEMENTS OUTSIDE THE RENOVATION AREA WILL NOT HAVE THEIR CURRENT WIND LOAD RESISTANT CAPACITY COMPROMISED BY THE PROPOSED NEW CONSTRUCTION. APPROVAL OF THESE PLANS IN NO WAY RELIEVES THE CONTRACTOR OR BUILDER OF COMPLYING WITH ORDINANCES OF LOCAL, ST LUCIE COUNTY STATE OR FEDERAL JURISDICTIONS. NOTE: THESE PLANS AND ALL ASSOCIATED DOCUMENTS ARE VALID FOR REPAIR CONSTRUCTION ONLY UPON STAMPED APPROVAL FROM APPROPRIATE GOVERNING JURISDICTION. THESE PLANS ARE VOID AND SHALL NOT BE USED FOR CONSTRUCTION OR ANY OTHER PURPOSE WITHOUT THE CITY OF STUART BUILDING DEPARTMENT REVIEW AND APPROVAL. NOTE: ADDITION/ALTERATION F.B.C. 7th ED. 2020 EXISTING BUILDING (section 602,603,604) ADDITION: AN EXTENSION OR INCREASE IN FLOOR AREA, NUMBER OF STORIES OR HEIGHT OF A BUILDING OR STRUCTURE. ALTERATION: ANY CONSTRUCTION OR RENOVATION TO AN EXISTING STRUCTURE OTHER THAN REPAIR OR ADDITION. ALTERATIONS ARE CLASSIFIED AS LEVEL 1, LEVEL 2, LEVEL 3. THIS PROJECT IS CLASSIFIED AS ADDITION. LEVEL 1 Scale: N.T.S. DRAWING INDEX TABLE OF CONTENTS BUILDING PLANS CVR SITE LOCATION GENERAL NOTES NOA'S S-1 EXISTING 1ST FOUNDATION PLAN S-2 LOWER FLOOR & 2ND FLOOR PLAN S-3 EXISTING FLOOR PLAN S-4 WALL SECTION DETAILS S-5 NEW / EXISTING ROOF PLAN S-6 NOTES SPECIFICATIONS T-1 ROOF PLAN SECTIONS DETAILS P-1 NEW PLUMBING PLAN, RISER DIAGRAM NOTES P-2 NEW PLUMBING PLAN, RISER DIAGRAM NOTES M-1 NEW A/C PLAN, DUCT LAYOUT— DIAGRAM NOTES E-1 NEW LOWER LEVEL ELCETRICAL PLAN, NOTES E-2 NEW UPPER LEVEL ELCETRICAL PLAN, NOTES -6 � 5r III Date �Rev=sions ST LUCIE COUNTY COMMENTS 1 4/16/22 000, LO (.9 (N a o CN w a N p G N z X r Q o w =0) c� Lie M v0 X Ld o � IJw ro (14 V) U W W Z p p U� W W U �4 C0 W O E-4 Q O � xz� E-+ O W zW w Z �D �Cr ZW 04 W�II W �-1 W a LO r—I wkyglgM UI f4 H� S, PE ,•��OEN'S .< i PE o'. S A F �� //y��IT(i�b�NLY DRAWN J. V.H. CHECKED W.J.M. DATE 12/21/21 SCALE AS NOTED JOB NO. 2021 BROWN SHEET CVR —1 • • • Q Mr Ow 1l!40i*r*±44 (MATCH SLOPE AND EXISTING CONC EDGES TO EXI TING FLOOR SLAB FLUSH 30 NEW 3000 PSI CONCRETE VERIFY IN FIELD W/ NEW 4" CONC. FILL FILL SLAB W/ 6 MILL PLASTIC a p z TERMITE TREATED COMPLETELY 3 AROUND *PERIMETER TYP. 5'—O" j MATCH SLOPE AND EXISTING EDGES 1� w 0VERIFY VERIFY IN FIELD W/ NEW 4" CONC. FILL EXISTING WALL N > z w FAMILY ROOM o VAULT CEIL iO N o N 0 r- w > INSTALL ABU66 BASE LIVING ROOM W/2 OTY MTS 18 STRAPS NOTE: LOAD BEARING TO EACH COL SIMPSON VAULT CEIL INSTALL NEW P.T. 6X6 VERIFY IN FIELD W/ 5/8" DRYWALL WRAP INSTALL ABU66 BASE W/2 QTY MIS 18 STRAPS TO EACH COL SIMPSON , VERIFY IN FIELD NEW P.T. 6X STRUCTURA BEAM ABOVE TO REMAIN? VERIFY P m v NOTE: EXISTING FOYER SPIRAL STAIR I j 'VAULT CC14 -- TO REMAIN - EXISTING DOOR I TO REMAIN LAM 12'-4" I II '^T VERIFY IN FIELD q� II 12' O mrREMOVE WALLS I 60" SHOWN DOTTED I PATCH FLOOR AS REQD:j I � BATH `1 I LIVING ROOM //—J I 9'-0" CEIL. VAULT CEIL ii 1PATCH FLOOR AS REQD. �Y� SINK & W.C. LOCATION / VERIFY FLOOR SLAB EXISTING GROUND FL A/C III W.C. > SYSTEM,TO BE ERMIT II VED��J RATE 0 A/C PS VERIFY/CAP ALL EXISTING Q DRAIN LINES cr} I i m of w 9' 0" CEIL i i �\ i i \ , "1 a i iI l I TUB / z OU �� LL7 �1-- B W � � ------ cot- ZW I SI K L---� NEW 1 HR DOOR HALL X� BATH AND FRAME 9'-0" CEIL. r". III 9'_0" CELL. c REMOVE WALLS SHOWN DOTTED HR FlRREE w II - I VERIFY IN FIELD 1 W.C. C NEW 1 HOUR Il— RATED WALL REMOVE 4" WALL-�// i 4" STEP ICE I i a D 0-7 \ 6" 1 3'-4" 11'-7" I I VERIFY fN FIELD INSTALL NEW LAU DRY I I 9 o CEIL KITCHEN 3' 6" FIRE RATEDUL 14'-10" 8 VAULTED CEIL. I >ALL SLAB NEW GARAGE REMOVE VERIFY IN FIELD 4" WALL I I I 0 NEW 3000 PSI CONCRETE FILL SLAB W/ 6 MILL PLASTIC — — — — ----- ---- z i INSTALL NEW 2X6 STUD WALL W/ P.T. BOTTOM PLATE 0 I N I I 16" O.0 W/ NEW R-16 FILLED O uj I W/ BATT INSULATION 04 UL RATED 1 HR WALL w BK NO K 1 CAR GARAGE 9'-0" CE 9'-0" VERIFY CELL. 1 I NEW 3000 PSI CONCRETE I I FILL SLAB W/ 6 MILL PLASTIC cal TERMITE TREATED AROUND I AROUND ® PERIMETER TYP. MATCH SLOPE ANY, EXISTING EDGES VERIFY IN FIELD 4' +-NEW CONC. FILL TO noun OWNG MATCH SLOPE & EXISTING CONC EDGES Mn..DGGn ? TO EXISTING FLOOR SLAB TYP NEW 170 D ZONE GARAGE DOOR NOTE: EXISTING O MTL. DOOR & WINDOW NEW OPENING TO REMAIN -VERIFY 12'-0" INSTALL NEW 8" BLOCK WALL 20'-0" FILLED CELLS 4000 PSI GROUT # 5 BAR EACH CELL VERIFY W/ NEW R 11, FOIL INSULATION MATCH STUCCO TO EXIST WALL FOUNDATION 30'-0" EXISTING VERIFY CONC DRIVE TO REMAIN 8" CONIC COL TO REMAIN EXISTING 8" HEADER BEAM W/ ROUGH STUCCO FINISH MATCH STUCCO AT FIRST FLOOR AFTER WINDOWS ARE INSTALLED EXISTING 8" BLOCK WALL W STUCCO FINISH N WORK FIRST FLOOR NOTE: LOAD BEARING INSTALL NEW P.T. 6X6 W/ 5/8' DRYWALL WRAP INSTALL ABU66 BASE W/2 QTY MIS 18 STRAPS TO EACH COL SIMPSON VERIFY IN FIELD VERIFY ELEVATOR LOCATION AND FILL W/ NEW 4000 PSI CONCRETE TYP. SLAB W1 6 MILL PLASTIC TERMITE TREATED AROUND AT EXISTING ® PERIMETER TYP. MATCH SLOPE AND EXISTING EDGES VERIFY IN FIELD 4'+-NEW CONC. FILL RELOCATE EXISTING PLUMBING DRAIN LINE, PATCH FLOOR AS READ. VERIFY IN FIELD NOTE: NEW WD-9500 ELEVATOR INSTALL 18" DEEP BASE FOR ELEVATOR VIE PAD LOCATON' & PLAN DETAI SEE ELEVATOR SHOP DRAWINGS FOR TYPE, ELECTRICAL CONNECTIONS, MODEL SPECIFICATIONS- ALL UNDER SEPARATE STATE FLA PERMIT -VERIFY IN FIELD TYP. VERIFY SINKS TO BE REMOVED CAP ALL PIPES, DRAIN LINES VERIFY IN FIELD ALL CONDTIONS VERIFY SHOWER LOCATION FILL SLAB W/ NEW 3000 PSI CONCRETE FILL SLAB W/ 6 MILL PLASTIC TERMITE TREATED AROUND AROUND 0 PERIMETER TYP. MATCH SLOPE AND EXISTING EDGES VERIFY IN FIELD W/ NEW 4" CONC. FILL O VERIFY TUB LOCATION FILL SLAB RELOCATE EXISTING PLUMBING DRAIN LINE, PATCH FLOOR AS READ. VERIFY IN FIELD VERIFY SINKS, W.C. TO BE REMOVED CAP ALL PIPES, DRAIN LINES VERIFY IN FIELD ALL CONDTIONS FOR NEW FIXTURES INSTALL NEW 2X6 STUD WALL W/ P.T. BOTTOM PLATE 16" O.0 W/ NEW R-16 FILLED W/ BATT INSULATION UL RATED 1 HR WALL w 0 m Q i0 O N U- o> z O 0 w to INSTALL NEW ELEC TANKLESS ON DEMAND ELEC W.H. SEE P-1 REMOVE EXISTING HWH VERIFY IN FIELD CAP ALL PIPES SEE SHEET P-1 FUTURE WASHER DRY LOCATION VERIFY IN FIELD WALL CONDTIONS MODIFY AS REQUIRED LOWER LEVEL FLOOR PLAN _ SCALE: 1 /4" = 1'--0" BUILDING NOTES: THE STRUCTURE IS DESIGNED TO BE SELF-SUPPORTING AND STABLE AFTER THE BUILDING IS FULLY COMPLETED. IT IS SOLELY THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE ERECTION PROCEDURE AND SEQUENCE AND TO INSURE THE SAFETY OF THE BUILDING AND ITS COMPONENT PARTS DURING ERECTION. THIS INCLUDES THE ADDITION OF WHATEVER SHORING, SHEETING, TEMPORARY BRACING, GUYS OR TIEDOWNS WHICH MIGHT BE NECESSARY. SUCH MATERIAL SHALL REMAIN THE CONTRACTOR'S PROPERTY AFTER IT IS SOLELY THE CONTRACTOR'S RESPONSIBILITY TO FOLLOW ALL OSHA APPLICABLE SAFETY CODES AND REGULATIONS DURING ALL PHASES OF CONSTRUCTION. MECHANICAL FRAMING LOADS, OPENINGS AND STRUCTURE IN ANY WAY RELATED TO THE MECHANICAL REQUIREMENTS ARE SHOWN FOR BIDDING PURPOSES ONLY. CONTRACTOR TO VERIFY THAT ELECTRICAL, PLUMBING OR OTHER EXISTING ELECTRICAL PIPING OR NEW PIPING, DUCTWORK DOES NOT CONFLICT WITH PROPOSED TRUSS LOCATIONS CONCRETE NOTES: ALL REINFORCING STEEL SHALL BE ASTM A615 GRADE 60. C.I.P. CONCRETE CONSTRUCTION OR CONTROL JOINTS IN SLAB ON GRADE TO BE AS SHOWN ON PLANS. WHERE NOT SHOWN, LIMIT CONTROL JOINT SPACING TO NO GREATER THAN 15 FEET ON ANY SIDE FOR 5 INCH SLABS AND 12 FEET FOR 4 INCH SLABS ON GRADE. THE SECTIONS BOUNDED BY CONTROL OR CONSTRUCTION JOINTS SHALL BE APPROXIMATELY SQUARE, WITH THE LENGTH TO WIDTH RATIO LESS THAN 1.5. COORDINATE CONCRETE WORK WITH ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR ARCHITECTURAL FINISHED CONCRETE, RECESSED AREAS, EMBEDDED ITEMS, AND SPECIAL CONTROL JOINTS. PROVIDE DOWELS IN FOOTINGS TO MATCH VERTICAL WALL AND PIER REINFORCING. PROVIDE CORNER BARS AT WALL AND FOOTING CORNERS TO MATCH HORIZONTAL REINFORCING. SEE BAR SPLICE TABLE BELOW FOR MINIMUM LENGTH OF EACH LEG. UNLESS OTHERWISE NOTED OR DETAILED, ALL REINFORCING BAR SPLICES SHALL BE IN ACCORDANCE WITH THE TABLE SHOWN BELOW: CONCRETE SPLICES TYPE A TYPE B BAR (NON TOP BAR) (TOP BAR) SIZE LENGTH (IN) LENGTH (IN) #3 14 18 #4 19 24 #5 23 30 #6 30 40 #7 41 54 #8 55 71 #9 69 90 #10 88 114 #11 108 140 TOP BARS ARE HORIZONTAL REINFORCEMENT SO PLACED THAT MORE THAN 12 IN. OF FRESH CONCRETE IS CAST IN THE MEMBER BELOW THE REINFORCEMENT. PROVIDE THE FOLLOWING MINIMUM CLEAR COVER FOR REINFORCING STEEL FROM SURFACE OF CONCRETE: • FOR CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH: 3" IN GENERAL 2" FOR FOUR INCH SLABS ON GRADE • FOR CONCRETE SURFACE EXPOSED TO THE WEATHER OR AGAINST WHICH BACKFILL WILL BE PLACED: 2" FOR #6 BARS AND LARGER 1-1/2" FOR #5 BARS AND SMALLER EXCEPT AS NOTED FOR PRECAST PANELS. • FOR SURFACES OTHER THAN ABOVE: 1-1/2" FOR COLUMN SPIRALS OR TIES, OR STIRRUPS (EXCEPT PAN JOISTS) 3/4" FOR SLABS AND FOR STIRRUPS IN PAN JOISTS TOLERANCES FOR BAR COVER ARE t 3/8 INCH FOR CONCRETE HAVING A THICKNESS OF 8 INCHES OR LESS AND t 1/2 INCH FOR CONCRETE HAVING A THICKNESS GREATER THAN 8 INCHES. TOLERANCE FOR LONGITUDINAL LOCATION OF BENDS AND ENDS OF REINFORCEMENT SHALL BE t 2 INCHES EXCEPT AT DISCONTINUOUS ENDS OF MEMBERS WHERE THE TOLERANCE SHALL BE t 1/2 INCH. TOLERANCE FOR BAR SPACING IS t 2 INCHES. TOLERANCE FOR LENGTH OF LAP SPLICE IS+-1 INCH, AND TOLERANCE FOR EMBEDDED LENGTH IS f 1 INCH. NOTE: MATERIAL DIMENSION MATERIAL DIMENSIONS ON PLAN REFLECT NOMINAL DIMENSIONS IE: 5/8" PLYWOOD IS 19/32", 2X12 IS 11"X11j", 8" BLOCK IS 7j". AREA CALCULATIONS EXISTING LIVING: 1,840 UPPER BR & BATH 855 GARAGE: 300 COVERED PORCH: 275 COVERED ENTRY: 25 SF SF (NEW) SF SF SF TOTAL: 3,295 SF TOTAL A/C 2,970 S.F. WALL LEGEND EXISTING 8" WALL 8" TO REMAIN NO WORK NEW 6" U.L WALL 6" 1 HOUR U.L RATED NEW 8" BLOCK WALL W/ 8" CELL FILLED CELL 4000 PSI # 5 BAR EACH CELL NEW 6" R-16 WALL ® 6" NEW 2X6 WALL 12" O.C. NEW 4" WALL 4" NEW W/ 5/8" DRYWALL EXISTING 4" WALL TO C_-----4" REMOVE BE REMOVED --- — — NOTE: NON LOAD BEARING VERIFY IN FIELD NOTE: LOAD BEARING NEW 6' X6' P.T.COL W 5//8' DRYWALL WRAP V�RIFY IN FIELD NEW 6" OR 4" WALL W/ 5/8" DRYWALL WOOD POCKET DOOR 2'-8" POCKET EXISTING 8" CMU EXISTING CELL m 8" CELL EXISTING NEW 4000 PSI CONCRETE FILL SLAB 6 MILL PLASTIC LL�I�J TERMITE TREATED TED AROUND COMPACTED ® PERIMETER -" -TYP. VERIFY IN FIELD - - EXISTING GROUND FL. A/C I� SYSTEM TO BE REMOVED IA?K I NO WORK THIS PERMIT—� SEE ELEVATOR SHOP DRAWINGS FOR TYPE, ELECTRICAL CONNECTIONS, MODEL AND SPECIFICATIONS- ALL UNDER SEPARATE FLA STATE PERMIT -VERIFY IN FIELD TYP. NEW 4000 PSI CONCRETE 48X60 FILL SLAB W/ 6 MILL PLASTIC NEW ELEV CONCRETE NOTES ALL CONCRETE WORK SHALL CONFORM TO THE BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE (ACI 318-19 PLUS UPDATES) SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS (ACI 301-16 PLUS UPDATES) OF THE AMERICAN CONCRETE INSTITUTE. FABRICATED IN ACCORDANCE WITH THE A.C.I. BUILDING CODE (LATEST EDITION) AND THE LATEST MANUAL OF STANDARD PRACTICE (A.C.I. 315). SHOP DRAWINGS OF ALL REINFORCING STEEL MUST BE APPROVED BY THE ENGINEER BEFORE FABRICATION. CONCRETE SHALL BE A MIX DESIGNED TO SECURE A STRENGTH OF MIN 4000 PSI (UNLESS OTHERWISE SPECIFIED) AT 28 DAYS FOR THE SLAB AND FOOTINGS SLUMP SHALL BE A MINIMUM OF 3" AND A MAXIMUM OF 5". CONCRETE DURING AND IMMEDIATELY AFTER DEPOSITING, SHALL BE THOROUGHLY COMPACTED BY MEANS OF MECHANICAL VIBRATION. NOTE: THE PROPOSED RENOVATIONS DO NOT STRUCTURALLY ALTER THE REMAINING EXISTING STRUCTURAL SYSTEMS AND A REQUIREMENT TO UPGRADE EXISTING WINDOWS BY THIS APPLICATION IS NOT WARRANTED, FOR THIS PERMIT. EXISTING BUILDINGS COMPONENTS AND ELEMENTS OUTSIDE THE RENOVATION AIREA WILL NOT HAVE THEIR CURRENT WIND LOAD RESISTANT CAPACITY COMPROMISED BY THE PROPOSED NEW CONSTRUCTION, APPROVAL OF THESE PLANS IN NO WAY RELIEVES THE CONTRACTOR OR BUILDER OF COMPLYING WITH ORDINANCES OF LOCAL, COUNTY STATE OR FEDERAL JURISDICTIONS. NOTE: THESE PLANS AND ALL ASSOCIATED DOCUMENTS ARE VALID FOR CONSTRUCTION ONLY UPON STAMPED APPROVAL FROM APPROPRIATE GOVERNING JURISDIC-nON. THESE PLANS ARE VOID AND SHALL NOT BE USED FOR CONSTRU(;TION OR ANY OTHER PURPOSE WITHOUT THE BUILDING DEPARTMENT REVIEW AND APPROVAL. w a cLL o� xa 3n of o� a� w� oz' c4 HJ r wz mw 0 z� �z a- x� �a co zw aQ ww x� �w m N oLoo z 0 OI o a o w a 00 w ° a a ( G z c"I <w I,0 ID u oz n Tz O m Z \J O a OL LS a � o_ zo Ll F w r< �0 3 a 00 =� O nnn J o 2 o W M V oa X J 0 u- a< w NI. 0_ a o f to J a (N(n U z- �o �o a= UZ zw oa o z, a xw L; a ¢. uw N � Y z w ~ z �tt Zaw NN W W E­4 7 �= H s Z 6 w� O j H oas O a wzo _? m w ~ F+� Z v o zac z E"1 � a p y C C3 f•�l z asaw U~w c lid w Lo O �aa oa r� f"1 oa wvoz a ox >zx az iw to v, owe s� w wm aza a <�zw �r azz w r WILLIAM J. MATHERS, PE � � a w a # 1>59 /; , c � a C58 ";4a "�, ATE OF P G:, STFfG 1( 0z� I w� v, U �w �a ;ww w Ll o_� Gov, Wzo 2os �o U(n r rr a: w DRAWN J.V.H. CHECKED W.J.M. DATE 10/21/21 SCALE AS NOTED JOB NO. 2021- BROWN SHEET S-1 3 I KN NEW 4" 3000 PSI CONCRETE FILL SLAB W/ 6 MILL PLASTIC TERMITE TREATED AROUND 0 PERIMETER TYP. VERIFY IN FIELD A/C A/C Y 3 z O z w > O m Q O Lr 0= O OJ r 3 M O Z z O U O Z Lu (n X W 8" O 30'-0" 8" COL TO REMAIN O4 EXISTING 8" COL TO REMAIN 18'� VERIFY STRUCTURAL BEA A13OVE TO REMAIN VERIFY ENCLOSED PORCH 9'-4" CEIL VERIFY EXISTING OPENING NOTE:EXISTING WINDOW AND FRAME TO REMAIN VERIFY IN FIELD —o iV o Z n W VERIFY A/C LOCATION NEW UNITS BY OTHERS NOT PART OF THIS PERMIT OR SCOPE OF WORK 3'-0" 28'-8" �d VERIFY INSIDE DIM. LIVING ROOM VAULT CEIL. REMOVE WALLS SHOWN DOTTED PATCH FLOOR AS O VERIFY REMOVE WALLS SHOWN DOTTED PATCH FLOOR AS REOD II I I� EXISTING 4" WALLS TO II BE REMOVED TYP. I• I I NOTE: NON LOAD BEARING VERIFY IN FIELD ABU66 1 SIMPSION ABU66 T. 6X6 1 W/ NEW P.T. 6X6 FOYER AENG NOTE: VATO O1 VAULT CEIL. UND P SIT ATE EXISTING DOOR TO REMAIN 12 m� 12'-4"VERIFY STAIRO �2 VIF V REMOVE WALSHOWN DOTTED PATCH FLOOR AS READ. VERIFY FOR NEW WALL o zalti. SINK `!/ BATH EXISTING GROUND FLOOR A/C 9'-O" CEIL. SYSTEM TO BE REMOVED I SINK FLOOR S ABN IN ITS ENTIRETY SYSTEM TO BE REMOVED NO WORK THIS PERMIT I I W C VERIFY IN FIELD I FILL IN SHOWER W/ -7� NEW 3000 PSI CONC //" --- --I REMOVE ALILSTYP.PANTRY WALLS 55' NEW WALL M III I / / VERIFY. 3'-6" / \ I CL / 66 VERIFY. (--� I 9'-0" CEIL U i i ( TUB �. o I L� OG1-- ---- \=-__ p zw I Sltil( KITCHEN CABINET HUTCH FY L___. z BowL SEE SHOD DWG HALL X° BATH SINK 9'-O" CEIL. wa11 SINK 013' V- 4" ZCABISEE E704 HUTCH DWG — — — — — — — — — — — — — — — - Y 0 Z 3 3 IC NEW OM O to BAINET / HUTCH Z w SEE SHOP DWG -� of W BK NOOK > 9'-0" CEIL. x W NOTE: SEE SHEET S-3 NEW GARAGE DOOR DETAILS G% F" ON •� t INSTALL NEW 2X6 STUD WALL P.T. BOTTOM PLATE 16" O.0 W/ NEW R-16 FILLED b cc W/ BATT INSULATION N U RATED 493 1 HR WALL 1 CAR GARAGE 9'-0" VERIFY CEIL. �NSH4 HUTCH UK visnNA MR.000R I K1 ., 30'-0" NEW 170 D ZONE GARAGE DOOR ONEW MASONARY OPENING 12'-0" 20'-0" LOWER LEVEL FLOOR PLAN a NOTE:VERIFY ELEVATOR LOCATION VERIFY ELEVATOR SEPRATE PERMIT) VERIFY PIT LOCATI N 18" THEN FILL W/ NEW 4000 PSI CONCRETE SLAB W/ 6 MILL PLASTIC,TERMITE TREATE AROUND THE PERIMETER AS REQUIRED TYP. MATCH SLOPE AND EXISTING EDGES VERIFY IN FIELD 4' +- NEW CONC. FILL NOTE: SEE SHOP DWG, PLAN FOR ELEVATOR P SEE ELEVATOR SHOP DRAWINGS LOCATION & PLAN DETAILS FOR TYPE, ELECTRICAL CONNECTIONS, MODEL SPECIFICATIONS- ALL UNDER SEPARATE STATE FLA PERMIT -VERIFY IN FIELD TYP. NOT PART OF THIS PERMIT OR SCOPE OF WORK NOTE: VERIFY WET LOCATIONS VERIFY EXISTING FLOOR SLAB OLD SHOWER & TUB LOCATION VERIFY FLOOR SLAB, CAP OLD PLUMBING & DRAIN LINES VERIFY IN FIELD EXISTING GL. BLOCK PANEL �— 48" WINDOW TO REMAIN VERIFY IN FIELD 8" EXISTING WALL VERIFY IN FIELD SEE PLUMBING PLAN FOR FIXTURES TO REMAIN / MODIFIED VERIFY IN FIELD FOR NEW USE NEW TILE OVER EXISTING CONCRETE TO REMAIN EXISTING GL. BLOCK PANEL WINDOWS TO REMAIN VERIFY IN FIELD SEE PLUMBING PLAN FIXTURES TO REMAIN / MODIFIED VERIFY IN FIELD FOR NEW USE LOCATIONS �— EXISTING 200 AMP PANEL TO REMAIN ( MODIFIED VERIFY IN FIELD ALL NEW ELECTRICAL WORK UNDER SEPARATE PERMIT /11'-WINDOWS EXISTING GLASS BLOCK PANEL TO REMAIN VERIFY IN FIELD > O m Q (0 O I O CV Lei, r-` w o> Z O U W In WALL LEGEND EXISTING 8" WALL TO REMAIN NO WORK NEW 6" R-16 WALL 6" 1 HOUR U.L RATED NEW 8" BLOCK WALL W/ 8" CELL FILLED CELL 4000 PSI # 5 BAR EACH CELL NEW 6" R-16 WALL ® 6" NEW 2X6 WALL 12" O.C. NEW 4" WALL 4" NEW W/ 5/8" DRYWALL EXISTING 4" WALL TO 4" REMOVE BE REMOVED NOTE: NON LOAD BEARING VERIFY IN FIELD NOTE: LOAD BEARING NEW 6" X6' P.T. COL VW 5//8" DRYWALL WRAP RIFY IN FIELD NEW 6" OR 4" WALL W/ 5/8" DRYWALL WOOD POCKET DOOR 2'-8" POCKET EXISTING 8" CMU FILLED CELL m 8" CELL EXISTING NEW 3000 PSI CONCRETE FILL SLAB W/ 6 MILL PLASTIC TERMITE TREATED AROUND ® PERIMETER TYP. VERIFY IN FIELD EXISTING GROUND FL. A/C SYSTEM TO BE REMOVED IA?5K NO WORK THIS PERMIT—� SEE ELEVATOR SHOP DRAWINGS FOR TYPE, ELECTRICAL CONNECTIONS, MODEL AND SPECIFICATIONS- ALL UNDER SEPARATE FLA STATE PERMIT -VERIFY IN FIELD TYP. NEW 4000 PSI CONCRETE 48X60 FILL SLAB W/ 6 MILL PLASTIC NEW ELEV NOTE: MATERIAL DIMENSION MATERIAL DIMENSIONS ON PLAN REFLECT NOMINAL DIMENSIONS IE: 5/8" PLYWOOD IS 19/32", 2X12 IS 1> 'X11 j", 8 BLOCK IS 7j". NEW 8" COL ON TOP OF BEAM VERIFY IN FIELD L 14'-7" VERIFY OPENING I 00 — N r CUSTON SHELF SYSTEM I M CLOSET 8'-4" CEIL. NOTE: ADDITIONALTERATION F.B.C. 7th ED. 2020 EXISTING BUILDING (section 602,603,604) ADDITION: AN EXTENSION OR INCREASE IN FLOOR AREA, NUMBER OF STORIES OR HEIGHT OF A BUILDING OR STRUCTURE. ALTERATION: ANY CONSTRUCTION OR RENOVATION TO AN EXISTING STRUCTURE OTHER THAN REPAIR OR ADDITION. ALTERATIONS ARE CLASSIFIED AS LEVEL 1, LEVEL 2, LEVEL 3. THIS PROJECT IS CLASSIFIED AS ADDITION. LEVEL 1 AREA CALCULATIONS EXISTING LIVING: 1,840 UPPER BR & BATH 855 GARAGE: 300 COVERED PORCH: 275 COVERED ENTRY: 25 SF SF (NEW) SF SF SF TOTAL: 3,295 SF TOTAL A/C 2,970 S.F. SCALE: 1/4" = V-0" L- -- — — — — — — — — — — — — — (- CUSTON SHELF SYSTEM CLOSET ( SM.CLOSET 8'-4" CEIL. L---------------- OPEN OVAULTED CEIL. 3 O z U' z U w 30'-0" O VERIFY IN COL FIELD TOP OF BEAM ,L BEAM BELOW TO REMAIN O z Z MASTER SUITE 3 9'-4" CEIL. w M r.�) w —� LINE OF PORCH WALL DOTTED BELOW 9,^D„ 4'-8" MIN OPENING I SINK 10 L HALL VAULT CEIL i� � A VAULT CEIL. 36" S.C. w 0 -- - o 3'-5" r I n NEW OPENING n _ VERIFY IN FIELD 36" S.C. 3'-9" VERIFY MIN. SPIRAL STAIR TO REMAIN 4X4 POST EXISTING F 2668 W001 22"x36" I EXIST DOO ATnc CCESS 3 BEDROOM 2 Q 8'-0" CEIL. w z <V 4 w J z V 3 z w > o F- N EGRESS WINDOW EXISTING 1 EXISTING 36" RAILING TO REMAIN VERIFY IN FIELD 30'-0" 13'-3" VERIFY IN FIELD OPENING LOFT SPACE 8'-4" CEIL. NOTE: REMOVE OLD CLOS T WALLS INSTALL 2X4 WALL W/ 5%FS" DRYWALL 6'-8" VERIFY IN FIELD 2'-0) N CLOSEI N NOTE: INSTALL NEW 2X4 STUD WALLS W/ 5E8' DRYWALL VERIFY IN FI LD BEDROOM 3 8'-0" CEIL W VERIFY IN FIELD 14" EGRESS WINDOW EXISTING UPPER LEVEL FLOOR PLAN 0 NEW 8" COL ON, TOP OF BEAM "- VERIFY IN FIELD 0, 00 I sN wd ¢3 zr (� a i U7Cq D T ,f o 8 OO s< I o OD oa 00 w NEW TILE OVER NEW �0 N 0 PT 5/8 PYL-WD DECK ?z N z 0 Fw O Z �J o O U o a 4 En " Mpp a � 00 0 m V °o S 0) n� w M V o� Ei J 0 w p I.L. Iz a w U)H it In � Q -+ z N 1n V ELEVATOR NOTE: o SEE LOWER LEVEL PLAN FOR ELEVATOR PAD LOCATION & PLAN DETAILS I zo SEE ELEVATOR SHOP DRAWINGS FOR TYPE, ELECTRICAL CONNECTIONS, MODEL O1 SPECIFICATIONS- ALL UNDER SEPARATE STATEa s FLA PERMIT -VERIFY IN FIELD TYP. NOTE: F SEE LOWER LEVEL PLAN FOR ELEVATOR a LOCATION rw ow w� V a mR o> 0 �a Qza a vW1 z a �W'1 Z H o ►-� cx-y o4 wN �/ W g N H O w O V �o o Z s 04 �zLL O rr�� N LL ~ V1 og Wiz EXISTING OLD CLO F"T WALLS SKIM WALL W, 5DRYWALL �aE-4 � ono o =x > aa row Wzz� �as z �ac a NN Q� o > F+� wza Lo �aa LO Tn V 1 ooa a o � z R O U o�w rya u W�L <_ a �a x JUI m W z z WILLIAM J. MATHERS, PE R FL # 19658 "„ o= U W i U �zz 0 zr' a ' Y _ lea =Q EOF moo o , qL <� 0 R I �tio f/r, o STRUCTORE.PNLY'` �z- Nwz �w amx 4z� " o oFw SCALE: 1/4" = 1'—O" M ems- 37 oCNx _� zzo w�W NOTE: THESE PLANS AND ALL ASSOCIATED DOCUMENTS ARE VALID FOR CONSTRUCTION ONLY UPON STAMPED APPROVAL FROM APPROPRIATE GOVERNING JURISDICTION. THESE PLANS ARE VOID AND SHALL NOT BE USED FOR CONSTRUCTION OFF ANY OTHER PURPOSE WITHOUT THE BUILDING DEPARTMENT REVIEW AND APPROVAL. WN .V.H. CHECKED W.J.M. DATE 10/21 /21 SCALE AS NOTED JOB NO. 2021-BROWN SHEET S-2 OxU z I -a SEE WALL SECTION S-4 TRUSS SHEET T-1 FOR NEW ROOF TRUSS SEE NOA, ON COVER SHEET FOR NEW ROOF TILE, SOFFIT SPECIFICATIONS NO WORK TO WALL STUCCO ONLY GARAGE DOOR FACE OF WALL AND OPENING NO WORK TO WINDOWS EXISTING VERIFY IN FIELD SEE SHEET S-1 EXISTING DOOR TO REMAIN NO WORK SEE SHEET S-1 CONS 4000 PSI CONC FILL \I 8' x 3/4 RAISED — STUCCO BAND NEW, MATCH EXISTING WALL SECTION S-4 TRUSS T T--1 FOR NEW ROOF TRUSS NOA, ON COVER SHEET FOR ROOF TILE„ SOFFIT SPECIFICATIONS 12 VERIFY 6 �! �11 NO WORK TO WINDOW \� ONLY GARAGE DOOR EXISTING VERIFY IN FIELD FACE �� / OF WALL AND OPENING SEE NOA, ON VER SHEET cOR \\ NEW ROOF TILE, OFFIT SPECIFIC?TIONS 12 �\ 6VERIFY \ APPLY 5/8- STUCCO TO WALL NEW STUCCO REPAIR WORK 9'-6" AF.F, 1 ONLY GARAGE DOOR FACE OF WALL AND THE OPENING ___+ TOP OF BEAM —�4 EXISTING VERIFY IN FIELD �I MATCH BACK TO ORGINAL CONDTION I T I I I I Ll EXISTING VERIFY IN FIELDS MATCH BACK TO ORGINAIj CONDTION 8" x 3/4 RAISED STUCCO BAND P EXISTING FINISH FLOOR LINE-0' _ _L-11 __ _ _ __ 170 D ZONE 12' GARAGE DOOR / SEE NOA, ON COVER SHEET GRADE LINE EXISTING AMERICAN PALM BEACH DOOR / VERIFY HURRICANE MASTER MODEL 824 TS / 12'-0" -4 / VERIFY NEW OPENING VERIFY PARTIAL FRONT GARAGE ELEVATION ELEVATION # 1 1/2" TOOLE[ STUCCO JOIN] 5/8 SMOOTH FINISF STUCCO & STUCCO BAND ROUGH FINISF STUCCC VERIn TOOLED STUCCO BAND DETAIL EXISTING BLOCK N.T.S. SEE NOA, SEE COVER SHEET FOR NEW GARAGE DOOR " VERIFY 12'AGE OR VERIFY 11 '-_�111111111111111111111111111111111111111111111111111'IIIIIV=' , :;dIIII1111111111111111111111111111111111111111111111111111L;- PROVIDE CONTINUOUS P.T. 2x6 NAILER AROUND GARAGE DOOR OPENING FASTEN AT JAMBS w/ 145d x 3" "HILT!" DRIVE PINS 0 8" O.C. FASTEN AT HEADER w/ 6' x 1/8 U.S. ANCHOR CONCRETE SCREWS OR EQ. 0 12" O.C. PER NOA REQUIREMENTS— O.H. GARAGE DOOR W/ TRACK ATTACHED — TO 2x6 PER MANUF. SPECS. 1x2 TRIM CONT. w CONT. CAULK BEAD NEW STUCCO ON CONIC, BLOCK—/1x2 TRIM CONT. w/ STUCCO ON CONC. BLOCK 5/8" w/ CONC. FILLED CELLS CONT. CAULK BEAD w/ GONG. FILLED CELLS VERIFY TO REMAIN TYP. EXISTING TO REMAIN PATCH NEW WALL AS REQUIRED NEW GARAGE DOOR ANCHORAGE DETAIL INSTALL ALL DOORS ANCHORS PER NOA SCALE: 1\" = 1'-O" HURRICANE MASTER MODEL 824 REQUIRFEMENTS NOA 20-0901.25 EXP DATE JULY 31 2025 -STUCCO ON C.B.S. CONTINUOUS CALK BEAD TYP. CONCRETE NOTES ALL CONCRETE WORK SHALL CONFORM TO THE BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE (ACI 318-19 PLUS UPDATES) SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS (ACI 301-16 PLUS UPDATES) OF THE AMERICAN CONCRETE INSTITUTE. FABRICATED IN ACCORDANCE WITH THE A.C.I. BUILDING CODE (LATEST EDITION) AND THE LATEST MANUAL OF STANDARD PRACTICE (A.C.I. 315). SHOP DRAWINGS OF ALL REINFORCING STEEL MUST BE APPROVED BY THE ENGINEER BEFORE FABRICATION. CONCRETE SHALL BE A MIX DESIGNED TO SECURE A STRENGTH OF MIN 4000 PSI (UNLESS OTHERWISE SPECIFIED) AT 28 DAYS FOR THE SLAB AND FOOTINGS SLUMP SHALL BE A MINIMUM OF 3" AND A MAXIMUM OF 5". CONCRETE DURING AND IMMEDIATELY AFTER DEPOSITING, SHALL BE THOROUGHLY COMPACTED BY MEANS OF MECHANICAL VIBRATION. 2X6 STUDS ® 16' O.C. — SIMPSON SP6 NEW [NAIL IMPSON AT TOP & 2X6 P6 BOTTOM TOP PER OF EACH STUD PLATE FR. SIMPSOIV SP6 AT TOP & BOTTOM! OF EACH STUD C 24" (2) 2X12"s SIMPSON MTST18 TYPICAL 1 MAX R BOL HURRI NE vv WASHERS a INSIALLLU 4" O.C. - 6" MIN. SIMPSON LTT20B TO BE INSTALLED AT ALL EMBEDMENT WALL OPENINGS, CORNERS, AND ENDINGS. USE A 1/2" EXPANSION ANCHOR W/ A MINIMUM EMBEDMENT OF 6"YP. HEADER BEARING 2X6 WALL DETAIL N,T,S, EXISTING TRUSSES BUILDING NOTES: THE STRUCTURE IS DESIGNED TO BE SELF-SUPPORTING AND STABLE AFTER THE BUILDING IS FULLY COMPLETED. IT IS SOLELY THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE ERECTION PROCEDURE AND SEQUENCE AND TO INSURE THE SAFETY OF THE BUILDING AND ITS COMPONENT PARTS DURING ERECTION. THIS INCLUDES THE ADDITION OF WHATEVER SHORING, SHEETING, TEMPORARY BRACING, GUYS OR TIEDOWNS WHICH MIGHT BE NECESSARY. SUCH MATERIAL SHALL REMAIN THE CONTRACTOR'S PROPERTY AFTER IT IS SOLELY THE CONTRACTOR'S RESPONSIBILITY TO FOLLOW ALL OSHA APPLICABLE SAFETY CODES AND REGULATIONS DURING ALL PHASES OF CONSTRUCTION. MECHANICAL FRAMING LOADS, OPENINGS AND STRUCTURE IN ANY WAY RELATED TO THE MECHANICAL REQUIREMENTS ARE SHOWN FOR BIDDING PURPOSES ONLY. CONTRACTOR TO VERIFY THAT ELECTRICAL, PLUMBING OR OTHER EXISTING ELECTRICAL PIPING OR NEW PIPING, DUCTWORK DOES NOT CONFLICT WITH PROPOSED TRUSS LOCATIONS CONCRETE NOTES: ALL REINFORCING STEEL SHALL BE ASTM A615 GRADE 60. C.I.P. CONCRETE CONSTRUCTION OR CONTROL JOINTS IN SLAB ON GRADE TO BE AS SHOWN ON PLANS. WHERE NOT SHOWN, LIMIT CONTROL JOINT SPACING TO NO GREATER THAN 15 FEET ON ANY SIDE FOR 5 INCH SLABS AND 12 FEET FOR 4 INCH SLABS ON GRADE. THE SECTIONS BOUNDED BY CONTROL OR CONSTRUCTION JOINTS SHALL BE APPROXIMATELY SQUARE, WITH THE LENGTH TO WIDTH RATIO LESS THAN 1.5. COORDINATE CONCRETE WORK WITH ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR ARCHITECTURAL FINISHED CONCRETE, RECESSED AREAS, EMBEDDED ITEMS, AND SPECIAL CONTROL JOINTS. PROVIDE DOWELS IN FOOTINGS TO MATCH VERTICAL WALL AND PIER REINFORCING. PROVIDE CORNER BARS AT WALL AND FOOTING CORNERS TO MATCH HORIZONTAL REINFORCING. SEE BAR SPLICE TABLE BELOW FOR MINIMUM LENGTH OF EACH LEG. UNLESS OTHERWISE NOTED OR DETAILED, ALL REINFORCING BAR SPLICES SHALL BE IN ACCORDANCE WITH THE TABLE SHOWN BELOW: CONCRETE SPLICES TYPE A TYPE B BAR (NON TOP BAR) (TOP BAR) SIZE LENGTH (IN) LENGTH (IN) #3 14 18 #4 19 24 #5 23 30 #6 30 40 #7 41 54 #8 55 71 #9 69 90 #10 88 114 #11 108 140 TOP BARS ARE HORIZONTAL REINFORCEMENT SO PLACED THAT MORE THAN 12 IN. OF FRESH CONCRETE IS CAST IN THE MEMBER BELOW THE REINFORCEMENT. PROVIDE THE FOLLOWING MINIMUM CLEAR COVER FOR REINFORCING STEEL FROM SURFACE OF CONCRETE: • FOR CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH: 3" IN GENERAL 2" FOR FOUR INCH SLABS ON GRADE • FOR CONCRETE SURFACE EXPOSED TO THE WEATHER OR AGAINST WHICH BACKFILL WILL BE PLACED: 2" FOR #6 BARS AND LARGER 1-1/2" FOR #5 BARS AND SMALLER EXCEPT AS NOTED FOR PRECAST PANELS. • FOR SURFACES OTHER THAN ABOVE: 1-1/2" FOR COLUMN SPIRALS OR TIES, OR STIRRUPS (EXCEPT PAN JOISTS) 3/4" FOR SLABS AND FOR STIRRUPS IN PAN JOISTS TOLERANCES FOR BAR COVER ARE f 3/8 INCH FOR CONCRETE HAVING A THICKNESS OF 8 INCHES OR LESS AND t 1/2 INCH FOR CONCRETE HAVING A THICKNESS GREATER THAN 8 INCHES. TOLERANCE FOR LONGITUDINAL LOCATION OF BENDS AND ENDS OF REINFORCEMENT SHALL BE t 2 INCHES EXCEPT AT DISCONTINUOUS ENDS OF MEMBERS WHERE THE TOLERANCE SHALL BE t 1/2 INCH. TOLERANCE FOR BAR SPACING IS t 2 INCHES, TOLERANCE FOR LENGTH OF LAP +SPLICE IS -1 INCH, AND TOLERANCE FOR EMBEDDED LENGTH IS t 1 INCH. 3 1/4" MIN EMBEDMENT WITH 2" SQUARE X 1/8" THICK HURRICANE WASHEf " . EXTERIOR DOOR 2X4 TRUSS® 24" OC INSTALL 3M CP 25 WB 8 SCREWS 1 HR FIRE RATED CAULK W/ 5/8 CDX PLYWOOD W/ TO UNDERSIDE EXISTING RAFTERS VERIFY IN FIELD 1 1/4 LONG TO BOTTOMOF RAFTER TYP EXISTING TRUSSES � , it !®24" O.C. 11 „ 11 ,I 11 1, ,1 �� �� :HOOD DOOR EXISTING RAFTERS 016" OC JAMB ADD 5/8 CDX PLYWOOD TYP. VERIFY IN FIELD 3/16" x 4" CORROSIVE EXISTING RESISTANT 'iAPCON" 0 2X6 FASCIA W/ 1/2" VENTED CONC. SCREWS INSTALLED 18" PLYWOOD SOFFIT 1/2" GYPSUM O.C. SINGLE LEAF TO REMAIN BOARD AND ® 12" O.C. DOUBLE R-19 INSULATION SIMPSON MTS18 SIMPSON MTS18 VERIFY IN FIELD SHIM MATCH EXISTING HURRICANE STRAP HURRICANE STRAP P.T. FURRING LEAF EVERY 24" OC WOOD CASING P.T. 2 x 4 TYPICAL TYP, EXTERI❑R DOOR JAMB DETAIL KITCHEN INSTALL ALL DOORS ANCHORS PER NOA 3' = 1'-O' _ } GARAGE NOTE: EXISTING BLOCK WALL - TO REMAIN 2X6 STUDS 0 16" OC VERIFY IN FIELD SP #2 OR BETTER W/ uj INSTALL NEW 4" USE NEW 5/8" DRYWALL BONDING AGENT TO 4000 PSI CONCRETE VERIFY IN FIELD UL U 493 6" WD WALL 5/8 PLYWOOD W/ ONE (1) HR WALLW/ Sd NAILS 0 6" OC NEW R19 INSULATION EDGE & 6" OC FIELD. ONE (1) HR WALL PT 2X6 PT BOTTOM PLATE SP #2 LUMBER —� 1/2"4 ANCHOR 0 —� 24" OC & 4" FROM EXISTING FOUNDATION — EXISTING SLAB Y ALL DOORS W/ MINIMUM 3" EMBEDDED TO REMAIN RAISE SLAB 4'° W/ NEW HURRICANE WASHERS TYP, VERIFY IN FIELD INSTALL 3M CP 25 WB 1 HR FIRE RATED CAULK TOP & BOTTOM TYP TYP. GARAGE DOOR ANCHORAGE DETAIL U L U 493 6" 1 HR WALL SCALE: 1\" = 1'-O" (2) 16d ® 12" 0 Od O.C. DETAIL AT 900 CORNER N.T.S. w 0 �a F U OU �a �N �o ww wo oN ow �o w� mw O � z� z a- `i 00 a¢ W w � U �s a� z aw r� m o� WF �Sa o� 0 ww as z aw �w oz iz �W r �^ m� W o� a� 00 z wo �a z ¢z mo as �o za am a� w? om w zw z? �z aw of as z� �o ag wm U W O� U Z �o zw �w as N V N X2 LO o g Oro w d N � p N r RE o�(��jj v q V LLI O CL } O F Ld M v0 E5 O lJLLJ Of Q Q N (n ox �U W m< W > sa w w a dry' m t� L Wr �_ m V �I a COU) Q z w� o a� m� N z }� r l ) ® C� h W 1"/ ^✓ W 0. > U U O O i Y Z G� Zoo� t-1 a Z zao W mow m WdZI r ry jL�,r. a w_ W ooQ 3"J Lo W wza w°o roa LlJ V1 ¢ o� wz� >a� U U � K O U O N Z rya ZnU az> =W mU2 F ago ws �¢z WILLIAM J. MATHERS, PE a o = a FL �4W8 1 N ¢ L ¢ s r 58 z m o � TATE OF �o w o it o E STR � Z W y WUZ �¢z W m� w �mL NOTE: M w THE PROPOSED RENOVATIONS DO NOT STRUCTURALLY ALTER THE REMAINING EXISTING STRUCTURAL SYSTEMS AND A REQUIREMENT w TO UPGRADE IT BY THIS PERMIT APPLICATION IS NOT WARRANTED. L� h O N wos EXISTING BUILDINGS COMPONENTS AND ELEMENTS OUTSIDE THE RENOVATION AREA WILL NOT HAVE THEIR CURRENT WIND LOAD oo F RESISTANT CAPACITY COMPROMISED BY THE PROPOSED NEW �Lw CONSTRUCTION. U ova APPROVAL OF THESE PLANS IN NO WAY RELIEVES THE zwW CONTRACTOR OR BUILDER OF COMPLYING WITH ORDINANCES ° w OF THE LOCAL, STATE OR FEDERAL JURISDICTIONS. aw az wo w _ I- W DRAWN J.V.H. CHECKED W.J.M. DATE OCT 2021 SCALE AS NOTED JOB NO. 2021 -BROWN SHEET S - 3 NOTE: ALTERNATE NAIL - 12d GUN NAILS (3"x .128) 12 ANCHORS REQUIRED TOP PLATE AT CORNER SCALE: 3/4" = 1'-0" SINGLE 2x6 TOP PLATE 2x6 TOP PLATE SPLICE BLOCK 2x6 HEM -FIR STUDS O 24" O.C. NOTE: ALTERNATE NAIL - 12d GUN NAILS (3'x .128) NOTE: 12 ANCHORS REQUIRED TOP PLATE SPLICE SCALE: 3/4" = 1'-O" NEW 2x4 DIAGONAL AS SHOWN AT GABLE END VERTICAL NAIL DIAGONAL TO EVERY GABLE END VERTICAL BRACE W/ (3) 16d NAILS BRACE INSTALLED AS REQUIRED BY TRUSS ENGINEERING 2"x4' DIAGONAL BRACING (4'-0" FROM GABLE ND) W/ (2)-10d NAILS O EACH DIAGONAL & (2)-10d NAILS O EACH TRUSS WEB BRACING PER TRUSS ENGINEERING INSTALL P.T. 2x4 NAILER W/ 1/2' x 7" "J" BOLT OR 5/8" x 7" EXPANSION BOLT O 24" O.C. W/ 3" x 3" x 1/4" WASHER — SEE FRAMING PLAN FOR SIZE, GRADE AND QUANTITY 20go. GALV. PLATE ANCHOR W (4) Bd NAILS EACH MEMBER, EACH SIDE P.T. 2X6 BOTTOM PLATE 3"X3"X1/4" WASHER 1/2" X 8" EXPANSION BOLTS O 18" O.C; 1/2" X 8" EXPANSION BOLTS O 18" D.C.— e POST & BEARING WALL CONNECTION DETAIL WOOD TRUSSES AT 2'-0" O.C. (SEE TRUSS ENGINEERING FOR REQUIRED LOADING 2x4x8' NAILED TO BOTTOM OF EA. TRUSS TOP CHORDS W/ (2) 10d RS NAILS. ROOF SHEATHING (4" OC TYP ALL CONDTIONS FOR NAILING W/ BD RS) 8d GALVANIZED NAILS O 4" O.C. TYPICAL DRIP EDGE P.T. 1 x2 P.T. 1 x6 2x8 NAILED W/ 16d NAILS O 4" O.0 NOTE: ADD ADDITIONPIL LAYER OF 15# FELT PAPER 12 WIDE N� 2 Q1Y GABLE END TRUSS W 2X8 BOTTOM CORDS DOUBLE GABLE END TRUSS NEW VERTICAL BRACE BY TRUSS COMPANY SHOP DWGS 5/8" STUCCO ON MTL LATH OVER 15# FELT PAPER ON APA RATED P.T. 15/32' EXPOSURE 1 GRADE PLY -WOOD SHEATHING R-19 MIN. INSULATION NAIL BOTTOM CORD OF GABLE END TRUSS TO P.T. 2x6 NAILER W/ 16d NAILS O 8" O.C. SEE SHEET T-1 FOR COL DETAILS TIE DOWN AND ANCHOR SPEC'S NEW P.T. tx2 FIRE STOP w TYPICAL 8"X16" CONC. TIE EXTEND PAPER BACKING BEAM EXISTING (4) #5 CONT. 12" OVER BEAM !..... • EXTEND LATH 12' OVER BEAM NOTE SEE HIB-91 BY T.P.I. FOR TEMPORARY BRACING DURING ERECTION. NO ADDITIONAL PERMANENT WIND BRACING REQUIRED, OTHER THAN SHOWN ABOVE, ON KOST TRUSS ON INDIVIDUAL TRUSS GABLE END DETAIL ENGINEERING SHEETS. NO WIND BRACING REQUIRED IN FLOOR OTHER THAN SCALE: 3/4" = 1'-0" SHOWN ON T NUEW TRUSS ENGINEERING. 1/4" CONTINUOUS BEAD OF CAULK EXISTING CBS WALL 7 BEHIND BUCK VERIFY IN FIELD / d - dl % STUCCO/ �/ \ NEW NP-.1 CAULK INSTALL P.T. BUCK HILTI NAIL CRS 099-122 O 6" O.C. SCREEN DOOR JAMB DETAIL d TYP. ALUM. WINDOW JAMB SLIDING GLASS DOOR JAMB a CAULK PER NOA 5/8" GREEN BD DRYWALL 4/4" x 2 3/4" SS CORROSIVE RESISTANT 'TAPCON" ANCHORS INTO CONC. THE SCREWS INSTALLED AS CALLED FOR ON WINDOW PRODUCTS APPROVAL (NOA) SCALE: 3/4" = 1'-0' DBL STUDS AS 2"x6' RIBBON ARC (BY BUILDER) 2"x6" BLOCKING DBL. STUDS AS, 2"x6" BLOCKING BELOW DBL. STUDS ABOVE (INSIDE GABLE END TRUSS) —� DBL. STUDS ABOVE 209a. GALV. PLATE ANCHOR W/ (4) 8d NAILS EACH MEMBER, EACH SIDE FLOOR SEE TRI 2X6 DBL INTERIOR W/g (4) AS REAL SEE TRU SIZE, GR FLOOR GIRDER CONNECTION O.0 FLOOR TRUSSES )W SEE TRUSS SHOP DRAWINGS SCALE: 1\" = 1'-O" 3 1/4" MIN EMBEDMENT WITH 2" SQUARE X 1/8" THICK HURRICANE WASHEI (2) 16d ® 12" 0 PLAN VIEW EACH SIDE OF EACH WINDOW USE (1) 14ga STRAP ON THE JACK STUD AND (1) 14go STRAP ON THE FULL HEIGHT STUD. STRAPS TO BE ON THE INSIDE OF THE WALL, EMBEDDED IN THE BEAM BELOW INSTALL NEW CEMENT BORAL VILLA 900 TILE NOTE: TILE NAILED ON ICE & WATER SHIELD POLY GLASS USA INC SURFACE INSTALL W/ 30# FELT OVER THE ICE & WATER PEEL -& STICK -TIN TAGGED W/ 16go. NON -CORROSIVE STAPLE W/ 1" CROWN OR 12go. WIRE RING-SHANKED NAILS, 3/4" LONG ON APA RATED 19/32" TREATED EXTERIOR GRADE PLYWOOD SHEATHING, NAIL W/ 8d NAILS (.131 x 2\" NAILS) 4" O.C. ALL MEMBERS. WITHIN 4'-O" OF ROOF EDGES NAIL PLYWOOD W/ 8d NAILS 3" O.C. WITHIN 4'-0" OF ALL ROOF EDGES). PLYWOOD TO BE PERPENDICULAR TO TRUSSES W/ STAGGERED JOINTS ENGINEERED APPROVED WOOD TRUSSES O 24" O.C. ALL TRUSS BRACING TO BE PLACED AS SHOWN ON TRUSS ENGINEERING SHOP DRAWING SHEETS 18 ga. MTS 18" WIDE SIMPSION GALV. STL. STRAP AT EA. TRUSS (SEE ANCHORING SCHEDULE) BY TRUSS ENGINEER SEE SHEET T-1 FOR COL DETAILS 2X6 SUB FASCIA W/ TIE DOWN AND ANCHOR SPEC'S 1X2 FASCIA W/ 1X2 METAL DRIP AK VERIFY / MATCH EXIST I i SEE WALL SECTION S-4 TRUSS SHEET T-1 FOR NEW ROOF TRUSS SEE NOA, CV-1 COVER SHEET FOR 1. NEW ROOF TILE, SOFFIT SPECIFICATIONS VERIFY EXISTING CBS BLOCK NAILED TO THE STUDS W/ (8) 16d NAILS. DETAIL AT 900 CORNER NAIL EXTERIOR PLYWOD TO BOTH STUDS W/ 8d NAILS O 4" O.C., SOLID BLOCKING REQ'D. IN N.T.S. FLOOR TRUSS SPACE BELOW DBL. STUDS ABOVE (FLOOR TRUSSES BELOW DBL STUDS WILL SUBSTITUTE FOR BLOCKING) DBL. STUDS ABOVE 149a. STRAP FROM STUDS TO BEAM BELOW SEE T-1 2"x6' RIBBON AROUND PERIMETER (BY BUILDER) NAIL TO TRUSS W/ (8) 16d NAILS -- PLAN VIEW 2"x4' BLOCKING BELOW DBL. STUDS ABOVE 2x4 P.T. BLOCK (COR PARTIAL 2X6 SECTIONS W/ 1 BETWEEN TRUSSES) W/ 1 /2" "J" BOLTS O 18" O.C. SCALE: 3/4" = 1'-O" I�I�� �II�O�11�11�11�\ NO WIND BRACING REQUIRED IN FLOOR TRUSSES OTHER THAN SHOWN ON TRUSS ENGINEERING. EXISTING WALL VERIFY EACH LOCATION W/ (3) 16d RS NAILS FOR EACH TRUSS VERIFY WALL LOCATIONS ROOF BRACING DETAIL NOTE: THESE PLANS AND ALL ASSOCIATED DOCUMENTS ARE VALID FOR REPAIR CONSTRUCTION ONLY UPON STAMPED APPROVAL FROM APPROPRIATE GOVERNING JURISDICTION. THESE PLANS ARE VOID AND SHALL NOT BE USED FOR CONSTRUCTION OR ANY OTHER PURPOSE WITHOUT THE CITY OF STUART BUILDING DEPARTMENT 1?EVIEW AND APPROVAL. NEW FLOOR TRUSSES O 24" O.C. SEE TRUSS PLAN BY TRUSS ENGINEER 11111 NOTE: VERIFY EXISTING JOIST NOT ALL FLOOR SECTIONS HAVE EPICORE DECK UNDERSIDE ..y _•; i�. '*_" TO REMAIN VERIFY IN FIELD A. 1, 1'. EXISTING TIE BEAM TO REMAIN • ABOVE WINDOWS & DOORS VERIFY IN FIELD PARTIAL WALL SECTION NOTE -NOT ALL FLOOR SECTIONS SCALE: 3/4" = 1'-0" HAVE ENCORE DECK UNDERSIDE N 2x6 BRACE O 24" OC W() 16d NAILS IN TO & B BRACING SCALE: 1/2" 1' 5\8" G BOARD P.T. FU WOOD L......... STUCCO ON C.B.S. CONTIN. CAULK NP-1 BEAD BRICK MOLD OPTIONAL EXTERIOR DOOR WOOD DOOR JAMB #8 SCREW 1 I" LONG 0 24" O.C. HILTI NAIL CRS 099-122 O 6" O.C. SHIM P.T. ix4 SCALE: 3" = 1'-O" Nlgri'1 SEE COVER SHEET FOR NQA'S SEE WALL SECTION AND TRUSS SHEET T-1 FOR NEW ROOF TRUSS SEE NOA, ON COVER SHEET FOR NEW ROOF TILE, SOFFIT SPECIFICATIONS VERIFY 12 6F— INSTALL NEW R-19 (MIN.) INSULATION INSTALL NEW 5/8" GYP. BOARD " SG GREEN BD" TYP P.T. i "x2" FIRE STOP DOUBLE 2"x6" TOP PLATE USE 2X6 U STRAP TYP SIMPSION PER MFR INSTALL TOP & BOTTOM TYP. WU r� d r� O U iw � L1 ,F U aG it wo s� a rc oN L, o �m wz mw o� z� J N 11 c za o� aQ w� ww 0 pp o O - z 3a, 0o I r o O '0 00 CN W ,z N Q� pL r �S =w W o (( ma O !J o� w � u _ �o tia z } m zJ _ 00) nnnnnn V W M s w X J �w zz x LL 5/8" GYP. BOARD (M-R. IN BATHS) W/ 11" TYPE 2 W I.-r S OR W #6 DRYWALL SCREWS O 6" O.C. N ALL MEMBERS TYP. o w D 2"x6" #2 (STUD GRADE) HEM -FIR J a N _ WOOD STUDS O 12" O.C. W/ SINGLE TOP PLATE (STUDS TO ALIGN W/ Bo w TRUSSES ABOVE o 0 > 2"x6 BLOCKING O PLYWD. SEAM NAIL PLYWD. TO BLOCKING W/ �, w 8d NAILS O 4" O.C. oz a NEW R-19 (MIN.) INSULATION a� NAIL BOTTOM PLATE TO RIBBON o W/ 16d NAILS O 4" O.C. aw NEW WOOD BASE aW APA RATED "STURD-1-FLOOR" OR EQ 48/24 - 23/32' EXPOSURE-1 GRADE PLYWOOD SET ON A CONT. r , 1/4" DIRA BEAD OF LIQUID NAIL FLOOR PANEL ADHEASIVE F+i AND" NAILED W/ 10d RING SHANK NAILS O 60/C IN FIELD O 3' O.C. AT EDGES �Uj m EDGES (O BATHROOMS PROVIDE ADDITIONAL o> F-+ W z LAYER 32/16 - 15/32" EXPOSURE-1 GRADE PLYWD. '„0 SET OVER 15# FELT & NAILED O 12" O/C W/ w a 8d RING SHANK NAILS) f--I f ; 18" DEEP FLOOR TRUSSES �W INSTALL 3/4" APA RATED t a O 24' O.C. SEE TRUSS PLAN a ((�(���,,,,^��,,'� eeeee�--1I«---111 n BY TRUSS ENGINEER EXPOSURE 1 GRADE P.T. PLYWOOD w m SEE SHEET T-1 FOR COL DETAILS a W TIE DOWN AND ANCHOR SPEC'S ^'_ SEE FLOOR TRUSS FRAMING PLAN z " ` E-i - FOR FIRESTOP EACH JOIST LOCATIONS O ,°-' z O r ,� Q 1,4 w FLOOR TRUSSES TYP. w z W l z '.:I '. r.. NOTE VERIFY EXISTING a M r , 6" E VERIFY FY EXISTING SLAB DECK 4+-i TO REMAIN LOCATE IN FIELD =o°- F"-i P.T. i "x2" FIRE STOP i UN.2 R W INSTALL NEW rave a ? ^ O "5/8" GYP. BOARD z>om W USG GREEN BD" TYP o �, EXISTING TIE BEAM TO REMAIN �^ � `" z ABOVE WINDOWS & DOORS w a a N W^^ VERIFY IN FIELD a r-i V 1 Lo ow m wza > LO So o 5/8" GYP. BOARD ON w�a a a P.T. 1 x 2 FURRING STRIPS = Q e� O 24" O.C. ,z., o z 0 w a PT 1 X2 FURRING O 16" OC `; o W/ CELOTX FOAM INSULATION _ a � TYP W/ 5/8" DRYWALL OPTION `w' -" sow FZz _ w w� „J Qom za a `_u�=w --EXISTING CMU TO REMAIN a B" CONCRETE BLOCK WALL w w > WILLIAM J. MATHERS, PE a ` FL #.19658 R-11 INSULATION BETWEEN �'� z P.T. 1 "x2" FURRING STRIPS O 24" D.C. " ma 010 ,Z VC — INSTALL NEW WOOD BASE 4" THICK EXISTING CONCRETE m •O L OF SLAB VERIFY IN FIELD NOTE: EXISTING CONC. c * . o. w STRIICf /L zw EXISTING SLAB T a 14 x(18" MONOLITHIC FIG. _EXIS?I2NG#FOOBTER /AS 0\\� 11zo zoo w CIJ CIO � csw Ww� TYPICAL 2—STORY WALL SECTION w w� W�a SCALE: 3/4" 1'-0"w zz izo z wwo cs� z-a 7/8" STUCCO ON MTL LATH OVER 15# FELT ON 32/16 - 15/32" EXPOSURE 1 GRADE PLYWOOD SHEATHING NAILED W/ 8d NAILS 6" O.C. FIELD ALL MEMBERS, 4" O.C. EDGES ALTERNATE NAIL - .113 x 2€" O 4" O.C. FIELD ALL MEMBERS, 3" O.C. EDGES INSTALL SIMPSION GALV. STL STRAP MTS 24 FROM FLOOR TRUSS TO WOOD STUD. USE SAME STRAP & NAIL PATTERN AS REQ'D FOR TRUSS ABOVE HOLD FLOOR TRUSSES BACK 1/2' FROM FACE OF CBS TO RECEIVE PLYWOOD -NAIL PLYWD. TO RIBBON, TRUSS. & PLATE W/ 8d NAILS O 3" O.C. 2'x6' RIBBON AROUND PERIMETER (BY BUILDER) NAIL TO TRUSS W/ (4) 16d NAILS— DBL END VERTICAL IN TRUSS GALV. STL. STRAP POWER DRIVE EMBEDDED INTO CONC TO TRUSS TYP SEE SHEET T-1 FOR COL DETAILS TIE DOWN AND ANCHOR SPEC'S SEE FLOOR PLAN & ELEVATIONS c FOR LINTEL BLOCK HEIGHT STUCCO CONTROL JOINT —� 2x4 P.T. BLOCK (CONTIN. OR BETWEEN TRUSSES) W/ 1/2" 'J' BOLTS O 24" O.C. OR HILTI DRIVE PINS .145"x3" O 4" O.G- EXTEND 15# FELT PAPER 6" BEYOND FLOOR TRUSS — EXTEND METAL LATH 12" BEYOND FLOOR TRUSS PATCH 5/8" STUCCO ON C.B.S. VERIFY IN FIELD SEE SHEET T-1 FOR COL DETAILS TIE DOWN AND ANCHOR SPEC'S NOTE: VERIFY EXISTING ��\\ STUCCO STOP AS . PT. PER COUNTY BLDLD G. DEPT. TERMITE TREAT ALL NEW WALLS TYPICAL NOTE: VERIFY EXISTING FINISH FLOOR LINE NOTE: VERIFY EXISTING APPROX. GRADE "I, • DRAWN J.V.H. CHECKED W.J.M. DATE 10/21/21 SCALE AS NOTED JOB NO. 2021—BROWN SHEET s-4 ro I SEE TYPICAL WALL SECTION FOR NEW ROOFING NOTES SHEET S-4 18'-1" A.F.F. TOP OF BEAM VERIFY SEE SHEET T-' NEW 8" STUCCO DETAIL BAND MATCH EXISTING STUCCO TYPICAL ,'6 10`0" VERIFY Y 2 ND FINISH FLOOR LINE SEE BLOCK DETAIL MATCH EXISTING STUCCO TYPICAL IXISTING V.I.F. GRADE SEE TRUSS ENGINEERING FOR ROOF DETAILS TRUSS SPECIFICATIONS VERIFY PITCH SEE SHEET T-1 12 5 rVERIFY `— + 26'-1" A.F.F� TOP OF BEAM INSTALL NEW 5/8" WIDE TOOLED STUCCO BAND OVER 3/4' PLYWOOD OVER 2 (TWO) LAYERS OF PEEL & STICK (SEE DETAIL S-4 WALL SECTION) SEE TRUSS SHOP DRAWINGS INSTALL ALL NEW WINDOWS PER NOA SEE CVR SHEET-1 i I II VERIFY EXISTING REAR ELEVATION 1/2" TOOLED STUCCO JOINT 5/8" SMOOTH FINISH STUCCO & STUCCO BANDS g o LLI Lj V)) o f3.1�IeL'I TOOLED STUCCO BAND DETAIL EXISTING BLOCK N.T.S. + 18'-1" A.F.F. .4, - TOP OF BEAM �1- VERIFY SEE SHEET T-1 5' WIDE TOOLED TUCCO BAND SI-E DETAIL ) TYPICAL 0'-0" 2 ND FINISH FLOOR LINE INSTALL ALL WINDOWS PER NOA SEE CVR SHEET-1 ==_FINISH FLOOR LINE 0'-0 EXISTING V.I.F. Y SCALE: 1/4" WALL LEGEND EXISTING 8" WALL NO WORK 0 NEW 4" R-19 WALL NEW 8" BLOCK WALL W/ FILLED CELL 4000 PSI NEW 4' WALL W/ NEW 5/8 DRYWALL BOTH SIDES NEW 4" TUBE COL ON TOP OF BEAM VERIFY IN FIELD SEE DETAILS ON SHEET T-1 O 14'-8" VERIFY OPENING I CUSTON SHELF SYSTEM i M CLOSET 8'-4" CEIL. I L r CUSTON SHELF SYSTEM CLOSET SM.CLOSET 8'-4" CEIL. I— -- — — — — — — -- — — — -- STRUCTURAL WALL TO REMAIN I I I I OPEN BELOW ED I M I ti NEW 4" TUBE COL ON TOP OF BEAM VERIFY IN FIELD 30'-0" SEE DETAILS ON SHEET T-1 BEAM BELOW TO REMAIN O¢ MASTER SUITE 9'-4" CEIL EXISTING SPIRALOSTAIR VERIFY IN FIELD LINE OF PORCH WALL BELOW DOTTED 4'-8" MIN OPENING HALL VAULT CEIL. NEW 4" TUBE COL ON TOP OF BEAM VERIFY IN FIELD SEE DETAILS ON SHEET T-1 9'-0" L SINK SINK m m � M BATH r w VAULT CEIL. Y 00 a o "' 3'-4" �rcrvnv�a =1N FlEID—_ 3'-9- MIN. NOTE: THE PROPOSED RENOVATIONS DO NOT STRUCTURALLY ALTER THE REMAINING EXISTING STRUCTURAL SYSTEMS AND A REQUIREMENT TO UPGRADE EXISTING WINDOWS BY THIS APPLICATION IS NOT WARRANTED, FOR THIS PERMIT.. EXISTING BUILDINGS COMPONENTS AND ELEMENTS OUTSIDE THE RENOVATION AREA WILL NOT HAVE THEIR CURRENT WIND LOAD RESISTANT CAPACITY COMPROMISED BY THE PROPOSED NEW CONSTRUCTION. APPROVAL OF THESE PLANS IN NO WAY RELIEVES THE CONTRACTOR OR BUILDER OF COMPLYING WITH ORDINANCES OF LOCAL, COUNTY STATE OR FEDERAL JURISDICTIONS. a0 12" 13'-3" VERIFY IN FIELD OPENING NOTE: 1. SEE AMERICAN STANDARD SPEC'S FOR MANUFACTURERS NUMBERS FOR TOILET ACCESSORIES. 2. ALL TOILET PARTITIONS SHOWERS DIMENSIONS ARE CENTER LINE OF PARTITION. (WHEN USED) 3. CONTRACTOR TO USE PLYWOOD BACKING BOARD FOR ALL NEW GRAB BARS, SHELVES & ACCESSORES TYPICAL VIF. NOTE: SEE FOUNDATION PLAN FOR ELEVATOR FOR LOCATION & PLAN DETAILS SEE ELEVATOR SHOP DRAWINGS FOR TYPE, ELECTRICAL CONNECTIONS, MODEL SPECIFICATIONS ALL UNDER SEPARATE STATE FL PERMIT -VERIFY IN FIELD TYP. PAD LOCATION & PLAN DETAILS SEE ELEVATOR SHOP DRAWINGS FLA STATE PERMIT -VERIFY IN FIELD TYP. SCALE: 1/4" = 1 NOTE: ADDITION/ALTERATION F.B.C. 7th ED. 2020 EXISTING BUILDING ADDITION: AN EXTENSION OR INCREASE IN FLOOR AREA, NUMBER OF STORIES OR HEIGHT OF A BUILDING OR STRUCTURE. ALTERATION: ANY CONSTRUCTION OR RENOVATION TO AN EXISTING STRUCTURE OTHER THAN REPAIR OR ADDITION. ALTERATIONS ARE CLASSIFIED AS LEVEL 1, LEVEL 2, LEVEL 3. THIS PROJECT IS CLASSIFIED AS ADDITION. LEVEL 1 NOTE: THESE PLANS AND ALL ASSOCIATED DOCUMENTS ARE VALID FOR CONSTRUCTION ONLY UPON STAMPED APPROVAL FROM APPROPRIATE GOVERNING JURISDICTION. THESE PLANS ARE VOID AND SHALL NOT BE USED FOR CONSTRUCTION OR ANY OTHER PURPOSE WITHOUT BUILDING DEPARTMENT REVIEW AND APPROVAL. �n o� �2 �N os w� U �Y 00 Y � aw Ys Y� o� wLL wo �F mw z� x` 00 z� "a ww YK a3 a� x m o� w� n o ow 0 wa Qa o �o �z a� cw z �w }w nl o? Wa a� U w 00 x z K we wY o. a Yo Y as oY zo as w �o a� z c w. z ww F N 0 of s zi wo wz �o U � oa U Z a� �o �N rw Y oa c� w LO LO 0 a O O o o >Zy 00 N A N O 0 W N) X o Es LLLJ W I.. to WW 0_ Q Q J U ccli N Z }m HQ Z QO m~ W an W zw zi 0 0 00 o i wZ, how �Q zoz ca, ,a 1iw ao� a U .yo zao oin < Q - a�� how ry waz W i "n �N ^' <a } a n_a zo_ O G a U i � a o� a >q3 U U � YOU DRAWN J.V.H CHECKED W.J.M. DATE OCT 2021 SCALE AS NOTED JOB NO. xxxx-xx SHEET s-5 ALL REINFORCING STEEL SHALL BE ASTM A615 GRADE 60. C.I.P. CONCRETE CONSTRUCTION OR CONTROL JOINTS IN SLAB ON GRADE TO BE AS SHOWN ON PLANS. WHERE NOT SHOWN, LIMIT CONTROL JOINT SPACING TO NO GREATER THAN 15 FEET ON ANY SIDE FOR 5 INCH SLABS AND 12 FEET FOR 4 INCH SLABS ON GRADE. THE SECTIONS BOUNDED BY CONTROL OR CONSTRUCTION JOINTS SHALL BE APPROXIMATELY SQUARE, WITH THE LENGTH TO WIDTH RATIO LESS THAN 1.5. COORDINATE CONCRETE WORK WITH ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR ARCHITECTURAL FINISHED CONCRETE, RECESSED AREAS, EMBEDDED ITEMS, AND SPECIAL CONTROL JOINTS. PROVIDE DOWELS IN FOOTINGS TO MATCH VERTICAL WALL AND PIER REINFORCING. PROVIDE CORNER BARS AT WALL AND FOOTING CORNERS TO MATCH HORIZONTAL REINFORCING. SEE BAR SPLICE TABLE BELOW FOR MINIMUM LENGTH OF EACH LEG. UNLESS OTHERWISE NOTED OR DETAILED, ALL REINFORCING BAR SPLICES SHALL BE IN ACCORDANCE WITH THE TABLE SHOWN BELOW: CONCRETE SPLICES TYPE A TYPE B BAR (NON TOP BAR) (TOP BAR) SIZE LENGTH (IN) LENGTH (IN) #3 14 18 #4 19 24 #5 23 30 #6 30 40 #7 41 54 #8 55 71 #9 69 90 #10 88 114 TOP BARS ARE HORIZONTAL REINFORCEMENT SO PLACED IT AT MORE THAN 12 IN. OF FRESH CONCRETE IS CAST IN THE MEMBER BELOW THE REINFORCEMENT. PROVIDE THE FOLLOWING MINIMUM CLEAR COVER FOR REINFORCING STEEL FROM SURFACE OF CONCRETE: • FOR CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH: 3" IN GENERAL 2" FOR FOUR INCH SLABS ON GRADE • FOR CONCRETE SURFACE EXPOSED TO THE WEATHER OR AGAINST WHICH BACKFILL WILL BE PLACED: 2" FOR #6 BARS AND LARGER 1-1/2" FOR #5 BARS AND SMALLER EXCEPT AS NOTED FOR PRECAST PANELS. • FOR SURFACES OTHER THAN ABOVE: 1-1/2" FOR COLUMN SPIRALS OR TIES, OR STIRRUPS (EXCEPT PAN JOISTS) 3/4" FOR SLABS AND FOR STIRRUPS IN PAN JOISTS TOLERANCES FOR BAR COVER ARE t 3/8 INCH FOR CONCRETE HAVING A THICKNESS OF 8 INCHES OR LESS AND t 1/2 INCH FOR CONCRETE HAVING A THICKNESS GREATER THAN 8 INCHES. TOLERANCE FOR LONGITUDINAL LOCATION OF BENDS AND ENDS OF REINFORCEMENT SHALL BE t 2 INCHES EXCEPT AT DISCONTINUOUS ENDS OF MEMBERS WHERE THE TOLERANCE SHALL BE t 1/2 INCH. TOLERANCE FOR BAR SPACING IS f 2 INCHES. TOLERANCE FOR LENGTH OF LAP SPLICE IS -1 INCH, AND TOLERANCE FOR EMBEDDED LENGTH IS t 1 INCH. ALL CONCRETE WORK SHALL CONFORM TO THE BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE (ACI 318-19 PLUS UPDATES) SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS (ACI 301-16 PLUS UPDATES) OF THE AMERICAN CONCRETE INSTITUTE. FABRICATED IN ACCORDANCE WITH THE A.C.I. BUILDING CODE (LATEST EDITION) AND THE LATEST MANUAL OF STANDARD PRACTICE (A.C.I. 315). SHOP DRAWINGS OF ALL REINFORCING STEEL MUST BE APPROVED BY THE ENGINEER BEFORE FABRICATION. CONCRETE SHALL BE A MIX DESIGNED TO SECURE A STRENGTH OF MIN 4000 PSI (UNLESS OTHERWISE SPECIFIED) AT 28 DAYS FOR THE SLAB AND FOOTINGS SLUMP SHALL BE A MINIMUM OF 3" AND A MAXIMUM OF 5". CONCRETE DURING AND IMMEDIATELY AFTER DEPOSITING, SHALL BE THOROUGHLY COMPACTED BY MEANS OF MECHANICAL VIBRATION. GENERAL NOTES: 1. CONTRACTOR SHALL VERIFY ALL CONDITIONS AT THE BUILDING AND NOTIFY THE OWNER OF ANY DISCREPANCIES BEFORE PROCEEDING WITH ANY WORK. 2. CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR FABRICATION PROCESSES AND CONSTRUCTION TECHNIQUES (INCLUDING SCAFFOLDING, BRACING, SHORING, ERECTION, ETC.) FOR COORDINATION OF VARIOUS TRADES, FOR SAFE CONDITIONS ON THE JOB SITE, AND FOR COMPLETE COMPLIANCE WITH THE WILUAM STEIGER OCCUPATIONAL SAFETY AND HEALTH ACT OF 1970 (OSHA). 3. DO NOT SCALE DRAWINGS. 4. CONTRACTOR SHALL THOROUGHLY FAMILIARIZE THEMSELF WITH THE DRAWINGS WHICH, IN TURN, MAY AFFECT THE COST OF THE PROPER COMPLETION OF THE WORK HEREIN SPECIFIED, AND CONTRACTOR SHALL INCLUDE EVERYTHING REQUISITE AND NECESSARY TO THE ENTIRE FINISHING OF THE WORK, NOT WITHSTANDING THAT EVERY ITEM NECESSARILY WORK BY REQUIRED SUCH Q S C K IS NOT SPECIFICALLY MENTIONED OR SHOWN. CONTRACTOR SHALL FURNISH ALL LABOR AND MATERIAL NECESSARY FOR THE COMPLETION OF ALL WORK AND DEMOLITION HEREINAFTER DESCRIBED. 5. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE CODES AND/OR REGULATIONS OF ALL COUNTY, STATE OF FLORIDA, F.B.C. 2020 7TH EDITION AND ALL OTHER CODES, AND/OR REGULATIONS BY ANY OTHER AUTHORITIES HAVING JURISDICTION OVER THE WORK. 6. PROTECT EXISTING ADJACENT BUILDING STRUCTURES, FLOOR DECK AND GROUNDS FROM ANY DAMAGE WHICH MAY OCCUR DURING PERFORMANCE OF ALL WORK. ANY DAMAGE TO EXISTING FACILITIES TO REMAIN WILL BE REPAIRED, REPLACED OR RESTORED TO THE ORIGINAL CONDITION AND TO SATISFACTION OF ENGINEER AT THE CONTRACTOR'S EXPENSE. 7. CONTRACTOR SHALL MAKE NO CHANGES WITHOUT WRITTEN APPROVAL FROM THE ENGINEER 8. GENERAL CONTRACTOR SHALL COORDINATE AND OBTAIN ALL PERMITS REQUIRED TO COMPLETE THE CONSTRUCTION OF THE WORK AS INDICATED ON THE DRAWINGS. 9. GENERAL CONTRACTOR SHALL INCLUDE IN THE BASE BID ALL FEES ASSOCIATED WITH THE CONSTRUCTION OF THIS PROJECT, INCLUDING BUT NOT LIMITED TO PERMIT FEES, DUMP FEES, SUBCONTRACTOR PERMIT FEES, DEMO AND IMPACT FEES. 10. CONTRACTOR IS TO COORDINATE AND ORGANIZE THE CONSTRUCTION PROCESS AND COMPLETE SAME IN A MANNER WHICH LEAST IMPACTS THE ADJOINING COMMON AREAS, IN ORDER TO MINIMIZE INCONVENIENCE TO THE TENANT. 11. CONTRACTOR SHALL VERIFY FINAL SELECTION OF FINISHES FOR DOOR & ELEC WORK WITH TENANT/OWNER BEFORE PROCEEDING WITH ANY NEW WORK. 12. IF DISSIMILAR METALS ARE TO BE JOINED, ENGINEER APPROVED INSULATION UNIONS MUST BE APPROVED. CONSTRUCTION NOTES: 1. ALL CONCRETE WORK SHALL CONFORM TO THE BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE (ACI 318-19 PLUS UPDATES) & SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS (ACI 301-16 PLUS UPDATES) OF THE AMERICAN CONCRETE INSTITUTE. 2, FABRICATED IN ACCORDANCE WITH THE A.C.I. BUILDING CODE (LATEST EDITION) AND THE LATEST MANUAL OF STANDARD PRACTICE (A.C.I. 315). SHOP DRAWINGS OF ALL REINFORCING STEEL MUST BE APPROVED BY THE ENGINEER BEFORE FABRICATION. 3. CONCRETE SHALL BE A MIX DESIGNED TO SECURE A STRENGTH OF MIN 5000 PSI AT 28 DAYS FOR THE NEW WALL AND SLUMP SHALL BE A MINIMUM OF 3" AND A MAXIMUM OF 5". CONCRETE DURING AND IMMEDIATELY AFTER DEPOSITING, SHALL BE THOROUGHLY COMPACTED BY MEANS OF MECHANICAL VIBRATION. 4. Note: Bridging truss design is the responsibility of the manufacturer since added bridging may be necessary to resist uplift. Joist manufacturer shall design the joists and bridging for uplift and submit design calculations verifying uplift capacity and capacity of special joists to carry all design loads. Calculations shall be stamped by a Registered Professional Engineer in the State of Florida. 5. LIGHT GAGE METAL FRAMING Material, design and manufacture shall be in accordance with the "Cold Formed Steel Design Manual of the American ran and Steel Institute. Provide tracks, blocking, lintels, clip angles, joist bridging, shoes, reinforcements and accessories to provide a complete metal frame system in accordance with manufacturers recommendations. 6. Any or all prints or duplications obtained from these plans are valid only if signed and sealed by a registered professional engineer representing Mathers Engineering engineer of record. All construction shall comply with Local, State, and National Codes. 7, All manufactured items shall be applied or installed in accordance with manufacturer's specifications and recommendations. And Product NOA'S 8. LUMBER: All lumber shall be Southern Yellow Pine or Western Red Cedar surfaced four sides. Southern Yellow Pine shall be treated with chromated copper arsenate (CCA) 0.40 LBS/CF of retention. Stringers, cross members, rails, wood post, nailers, and blocking shall be NO.2 or better in accordance with southern pine inspection bureau grading rules. All sizes as shown on plans. Decking if used shall "composite DECKING" in accordance with ALL NOA. PRODUCT APPROVALS All sizes as shown on plans and fastened using stainless steel or double hot dipped galvanized deck screws. HARDWARE: All hardware shall be new 316 GRADE stainless steel, All thur bolts AND ANCHOR CLIPS S.S. 316 GRADE TYPICAL All concrete masonry units shall be normal weight aggregate; see DESIGN DATA for required prism strength. All reinforcing steel shall be ASTM A615 Grade 60. The masonry contractor is to provide vertical bar positioners on all vertical bars to maintain reinforcing in the proper location. Unless otherwise noted or detailed, all reinforcing bar splices shall be in accordance with the table shown below: Bar Size #3 #4 #5 #6 #7 Lap Length (in) 16 24 32 40 48 The general contractor shall provide 7 and 28 day strength testing on the mortar and grout used in the filling of the masonry cores and shall submit mix to the engineer for approval. All masonry walls shall have horizontal galvanized masonry joint reinforcement at 16 in. o/c. Minimum wire size for the lon— gitudinal wires shall be 9 gauge unless noted otherwise on plans or specifications. The minimum lap length for the horizontal shall be 7 1/2 inches unless noted otherwise on contract documents. Provide ladder type joint reinforcing at single wythe walls. Joint reinforcing at exterior walls shall be hot dip galvanized. Joint reinforcing shall be discontinuous at masonry control joints and building expansion joints. Use type S mortar conforming to ASTM C 270. FORMWORK Contractor shall design and erect formwork in strict compliance with ACI 347. See typical details for Camber requirements. Contractor shall coordinate all openings as required for other trades. Openings where show on the structural drawings are to identify design intent only. The specific dimensions and locations shall be furnished or confirmed by the trade requiring the opening. Provide chamfers at all corners in concrete members exposed to view. Formwork to remain in place until concrete has attained enough strength to support all dead loodds plus a minimum of 50 PSF of additional construction load. CONTRACTOR SHALL BE RESPONSIBLE FOR... Contractor shall be responsible for protecting adjacent structures, streets, and sidewalks during excavation and construction. Contractor to verify all dimensions in field. Contractor shall work this set of drawings in conjunction with architectural and mechanical drawings for size, shape and location of slab openings. All sleeves, conduits, inserts, block -outs, bolts, plumbing items and drains shall be secured in place before pouring concrete. If any errors, discrepancies, conflicts or omissions appear in the drawings, specifications, or other documents, the contractor shall notify hte engineer in writing of such errors, discrepancies, conflicts or omissions prior to proceeding with any work which appears in question. The contractor shall use the structural drawings together with the architectural, mechanical, and electrical drawings to locate depressed slabs, slopes, drains, outlets, recesses, openings, reglets, bolt settings, sleeves, dimensions, etc. Potential conflicts shall be transmitted to the architect —engineer before proceeding with any work which appears in question. No shop drawings shall be submitted for Engineer review until after they have been reviewed by the contractor and noted for dimensioning, quantities and coordinated with other trade requirement and stamped with the contractor's approval seal. Engineer assumes no resposibility for dimensions, quantities, errors or omissions as a result of checking and reviewing any shop drawings. Any errors or omissions must be made good by contractor, irrespective of receipt, checking, or review of shop drawings by engineer and even though work is done in accordance with such drawings. NOTE: THE PROPOSED RENOVATIONS DO NOT STRUCTURALLY ALTER THE REMAINING EXISTING STRUCTURAL SYSTEMS AND A REQUIREMENT TO UPGRADE IT BY THIS PERMIT APPLICATION IS NOT WARRANTED. EXISTING BUILDINGS COMPONENTS AND ELEMENTS OUTSIDE THE RENOVATION AREA WILL NOT HAVE THEIR CURRENT WIND LOAD RESISTANT CAPACITY COMPROMISED BY THE PROPOSED NEW CONSTRUCTION. APPROVAL OF THESE PLANS IN NO WAY RELIEVES THE CONTRACTOR OR BUILDER OF COMPLYING WITH ORDINANCES OF LOCAL, STATE OR FEDERAL JURISDICTIONS. NOTE: THESE PLANS AND ALL ASSOCIATED DOCUMENTS ARE VALID FOR REPAIR CONSTRUCTION ONLY UPON STAMPED APPROVAL FROM APPROPRIATE GOVERNING JURISDICTION. THESE PLANS ARE VOID AND SHALL NOT BE USED FOR CONSTRUCTION OR ANY OTHER PURPOSE WITHOUT THE CITY OF STUART BUILDIING DEPARTMENT REVIEW AND APPROVAL. U W 7 W � S � F d H U O (J 2 W _N W o= o� aw W V �w ON wLL N O mw o� N �z a- _ N a 00 z� ¢¢ iX WW a� 0 Q� m oz W� 3a o� 0 wa ¢o U 00 z 3� ¢W �W oz s= W m� W o� Wa Q� s� z } wa c� a z az �o ¢ o� z� a° U W z o� �w z= aw y of as z� UW �o WZ �o N� VW �W oa UZ 13 �o 2 W �w oax U W N O 8 I CO a CO w N h � r O w Z 0 a_ °R 2 00) 0) PM 0) /� w � v� Es noEs L_J wF N Of `Z Q J N U) t� • i • • • • • WILLIAM J. MATGHERS, PE FL#119,6Y6ili! 'rJ 658 DRAWN J.V.H. CHECKED W.J.M. DATE 10/21 /21 SCALE AS NOTED JOB NO. 2021-BROWN SHEET S-6 ROOF- PLAN INU 1 NUJJ WUNK I U LJCIJ I II\JU NUUt- MATCH EXISTING PLY —WOOD DECK SCALE: 1 /4" = 1 '-0" D ROOF AND EXISTING ROOF TRUSS ORY TRUSS WORK, MATCH EXISTING ROOF —WOOD DECK, HEIL HEIGHT VIF. S-4 VERIFY EXISTING EPICORE FLOOR )OF TO ENTIRE DECK EERED TRUSS SHOP DRAWINGS 2"x8" P.T. STRINGER INSTALL PL 400 GLUE ALL SIDES TYP AS REQUIRED V.I.F. 2"x8" P.T. ° STRINGER 2"x8"x 5' P.T. ° RINGER SPLICE ZEWED WITH 2-1/2" "LEDDERLOCK" i" OC STAGGERED TYP. VGER REPAIR DETAIL (AS R TOP OF BEAM - OUCIM. w.1.0. THIS ROOF FRAMING PLAN SHOWS LOCATION AND DIRECTIONS OF ALL ROOF MEMBERS (TRUSSES AND GIRDERS). FOR INDIVIDUAL TRUSSES, SEE LAYOUT AND ENGINEERING SHEETS BY TRUSS MANUFACTURER, VOTE: VOTE FUTURE A/C WORK WILL REQUIRE ABOVE NTTIC ACCESS IN CEILING PROVIDED BY ONTRACTOR VIF NEW ATTIC HATCH LOCATION MATCH PLYWOOD ADD NEW 2X6 CAT MEMBERS TO EXISTING PLYWOOD, VERIFY DECK LEVEL TYP. VERIFY IN FIELD ALL CONDTIONS NO TRUSS WORK TO EXISTING ROOF MATCH EXISTING PLY —WOOD DECK SEE WALL SECTIONS S-4 INSTALL NEW ROOF TO ENTIRE DECK VERIFY IN FIELD EXISTING TIE BEAM VERIFY IN FIELD 29'-6" VERIFY IN FIELD NEW 4" TUBE 56 KSI STEEL COLUMN po o o 0rA 0 0 16' SPEC NEW V' EPDXY ANCHOR BOLTS 3/4" DIA SIMPSION TYP. TI n NEW 4" TUBE 56 KSI S EL COLUMN a W 1/4' BASE PLATE 16' O SPEC NEW 4" EPDXY ANCHOR BOLTS 3/4" DIA SIMPSION 7- TYP. 4 8w 4 8„v BEAM BEAM O BASE PLATE USE SIMPSION MTS 18 TWIST Scale: N.T.S. STRAPS EACH COL (2) TWO CITY NEW 4!' TUBE 56 KSI ANCHOR SSLEAVE SEE T-1 NEW 4" TUBE 56 KSI STEEL COLUMN W/ 1/4' BASE PLATE TYP. EXISTING COL —TIE BEAM VERIFY IN FIELD NEW COLUMN DETAIL Scale: N.T.S. NEW 4' TUBE 56 KSI S EL COLUMN W 1/4' BASE PLATE TYP. NEW 56 KSI STEEL COL W/ 1/4" BASE PLATE - WALL LEGEND EXISTING 8" WALL 8" TO REMAIN NO WORK NEW 6" WALL 6" U.L. 1 HOUR U.L. RATED NEW 8" BLOCK WALL W/ 8" CELL FILLED CELL 4000 PSI M 5 BAR EACH CELL NEW 6" R-19 WALL 2X6 WALL 12" O.C. NEW 4" WALL W/ 5/8" DRYWALL NEW 6" OR 4" WALL W/ 5/8" DRYWALL WOOD POCKET DOOR 2'-8" POCKET 4" NEW EXISTING 8" CMU FILLED CELL FT-18" CELL NEW 56 KSI STEEL COL o o W 1/4" BASE PLATE S�E 6ETAILS THIS PAGE ° 0 BEAM LEGEND 2X6 SYP-1 WOOD TRUSS 24" OC TYP. INSTALL ON TOP OF EXISTING TIE BEAM ON TOP OF DOUBLE 2X6 TOP PLATE 12"O.C. SEE WALL SECTION S-4 ANCHOR SCHEDULE 8 USE "SIMPSION GALV STEEL ANCHOR FOR G-1 FOLLOW ALL MFR. INSTALLATION REQ.'S USE "SIMPSION MTS 18" TWIST WOOD STRAP TRUSS A-1 NOTE USE (2) TWO QTY AT EACH COLUMN TYP. TOP 2XATE USE "SIMPSION 2X6 U—STRAP WOOD STRAP TYP USE "SIMPSION MTS 18" TWIST WOOD STRAP A-2 FOLLOW ALL MFR. INSTALLATION REQ.'S USE "SIMPSION MTS 18" TWIST WOOD STRAP A-3 FOLLOW ALL MFR. INSTALLATION REQ.'S USE "SIMPSION MTSAM 24" FLAT WOOD STRAP F-1 FOLLOW ALL MFR. INSTALLATION REQ.'S USE "SIMPSION MTSAM 24" FLAT WOOD STRAP G FOLLOW ALL MFR. INSTALLATION REQ.'S NOTE: ALL TO BE (2) OTHERWISE HEADERS & 2X12 SYP NOTED ON WOOD BEAMS #2 UNLESS PLAN STING COL —TIE BEAM VERIFY IN FIELD ALTERATION GENERAL NOTES: 1 REMOVAL OF THE EXISTING IMPROVEMENTS SHALL BE AS REQUIRED FOR THE PROJECT. THE MATERIALS REMOVED FROM THE SITE SHALL BE DISPOSED OF IN A PROPER AND LEGAL MANNER PER FEDERAL, STATE, AND OR LOCAL LAWS AND ORDINANCES. 2 EXISTING BUILDING ADDITIONS, WALLS FLOORS CEILINGS ELECTRICAL PIPES STRUCTURES, TO REMAIN SHALL BE PROTECTED FROM DAMAGE BY THE CONTRACTOR, ANY DAMAGE DURING CONSTRUCTION SHALL BE RESTORED, RECONSTRUCTED OR REPLACED BY THE CONTRACTOR AT HIS EXPENSE. ALL DAMAGES SHALL BE RESTORED OR REPLACED TO AT LEAST THEIR ORIGINAL CONDITION OR AS REQUIRED OR DICTATED BY FEDERAL, STATE, COUNTY, CITY OR LOCAL GOVERNING AGENCIES. ANY UTILITIES REQUIRED TO REMAIN IN SERVICE FOR EXISTING BUILDING ADDITIONS TO REMAIN SHALL BE PROTECTED. 3 IT IS THE RESPOSIBILITY OF THE CONTRACTOR TO INSPECT EACH DAY AND REMOVE ALL MUD, DIRT, GRAVEL AND LOOSE MATERIALS TRACKED, DUMPED, SPILLED OR WIND BLOWN FROM THIS SITE ONTO OTHER SITES, RIGHT OF WAYS, PUBLIC OR PRIVATE STREETS OR ROADS, DRIVEWAYS, YARDS OR SIDEWALKS. THE CONTRACTOR MUST CLEAN OR PICK UP DAILY IF NECESSARY. 4 IT IS THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE OWNER AND ALL THE UTILITY COMPANIES AND DEPARTMENTS. VERIFY THAT UTILITIES HAVE BEEN DISCONNECTED AND CAPPED BEFORE STARTING DEMOUT10N OPERATIONS. 5 IT IS THE RESPONSIBILITY OF THE CONTRACTORS TO OBTAIN ALL FEDERAL, STATE, COUNTY, CITY, AND LOCAL PERMITS FOR ANY AND ALL WORK REQUIRED UNLESS OTHERWISE NOTED. THIS SHALL INCLUDE ALL SUBMITTALS AS REQUIRED INCLUDING STORMWATER RUNOFF CONTROL. THE CONTRACTOR OR CONTRACTORS ARE RESPONSIBLE TO PAY FOR ALL REQUIRED PERMITS BY ANY OR ALL AGENCIES MENTIONED ABOVE UNLESS OTHERWISE NOTED BY THE CONTRACTOR OR SPECIFICATIONS. 6 THE CONTRACTOR MUST VISIT THE SITE AND STUDY EXISTING PHYSICAL BUILDING CONDITIONS, REVIEW EXISTING DRAWINGS, AND REACH THEIR OWN CONCLUSIONS ON WORK NECESSARY TO ACCOMPLISH INTENDED RESULTS DESCRIBED BY THE PROJECT DOCUMENTS. 7 ALL PIPES AND CONDUITS IN WALLS THAT ARE TO BE DEMOLISHED ARE TO BE REMOVED AND/OR RELOCATED AS REQUIRED. 8 JOBSITE INSPECTION MUST BE CONDUCTED TO EXAMINE EXISTING ROOF WALL, CONDITIONS, TO DETERMINE NATURE AND SCOPE OF WORK OR ANY DIFFICULTIES THAT MIGHT ARISE AT TIME OF WORK. IN ADDITION, EXAMINE ALL WORK THAT IS INTENDED TO REMAIN AS PART OF THE COMPLETED PROJECT AND REPORT ALL UNSATISFACTORY CONDITIONS TO OWNER PRIOR TO COMMENCEMENT OF WORK. EXERCISE EXTREME CARE DURING DEMOLITION SO AS NOT TO DAMAGE CONSTRUCTION AND OTHER STRUCTURES THAT ARE INTENDED TO REMAIN. ANYTHING DAMAGED AT TIME OF WORK IS TO BE REPAIRED AND/OR REPLACED TO MATCH EXISTING CONSTRUCTION AT CONTRACTORS EXPENSE. COMMENCE 9 UTILITY SERVICE: MAINTAIN EXISTING UTILITIES INDICATED TO REMAIN IN SERVICE AND PROTECT THEM AGAINST DAMAGE DURING SELECTIVE DEMOLITION OPERATIONS. 10 ALL EXISTING SERVICES, MECHANICAL, ELECTRICAL, AND PLUMBING, SHALL REMAIN IN CONTINUOUS OPERATION THROUGHOUT THE ENTIRE CONSTRUCTION PROCESS. IF IT BECOMES NECESSARY TO SHUT DOWN ANY OF THESE SERVICES, THE OWNER SHALL BE NOTIFIED, AS IDENTIFIED IN THE SPECIFICATIONS, BY THE CONTRACTOR. 11 GENERAL CONTRACTOR SHALL COORDINATE AND OBTAIN ALL PERMITS REQUIRED TO COMPLETE THE CONSTRUCTION OF THE WORK AS INDICATED ON THE TRUSS DRAWINGS. 12. GENERAL CONTRACTOR SHALL INCLUDE IN THE BASE BID ALL FEES ASSOCIATED WITH THE CONSTRUCTION OF THIS PROJECT, INCLUDING BUT NOT LIMITED TO PERMIT FEES, DUMP FEES, SUBCONTRACTOR PERMIT FEES, DEMO AND IMPACT FEES. 13. IF DISSIMILAR METALS ARE TO BE JOINED, ENGINEER APPROVED INSULA11ON UNIONS MUST BE APPROVED. NOTE: ADDITIONALTERATION F.B.C. 7th ED. 2020 EXISTING BUILDING (section 602,603,604) ADDITION: AN EXTENSION OR INCREASE IN FLOOR AREA, NUMBER OF STORIES OR HEIGHT OF A BUILDING OR STRUCTURE. ALTERATION: ANY CONSTRUCTION OR RENOVATION TO AN EXISTING STRUCTURE OTHER THAN REPAIR OR ADDITION. ALTERATIONS ARE CLASSIFIED AS LEVEL 1, LEVEL 2, LEVEL 3. THIS PROJECT IS CLASSIFIED AS ADDITION. LEVEL 1 NOTE: Contractor is responsible for bracing of structure during construction. All measurements to be verified by contractor prior to start of job. All hardware to be stainless steel ONLY NOTE: THESE PLANS AND ALL ASSOCIATED DOCUMENTS ARE VALID FOR REPAIR CONSTRUCTION ONLY UPON STAMPED APPROVAL FROM APPROPRIATE GOVERNING JURISDICTION, THESE PLANS ARE VOID AND SHALL NOT BE USED FOR CONSTRUCTION OR ANY OTHER PURPOSE WITHOUT THE CITY OF STUART BUILDING DEPARTMENT REVIEW AND APPROVAL. N 01) O 2 � oCO oo 00 0 00 04w a N N gin 11 04 04 ° (( � 0z O rn z14- V Ld M X_ lv�L 0 � w N (n o a cw U W 'Q �< >a U "o �G ,a w m' Z m a � a zr--� �1' Z 1D E , W U O O� NN Q �no o F�1 w a 0 a z rr W `" o W �oz z C U zQo a o wow <w E--i N w�a C�6WU) " u w_ 0 :m� L Q a ,^ L J a uGa �cz 'mow T__q ao, w=n: >a� moo' v, z wa U -U Lwm aza a U S w ao<^ WILLIAM J. MATHERS, PE ~ a a FL # 19658 owa 0 o >>. a r _ 9658 . fz ce tf zoo ✓ 'e:G y,a�'�j/ p�pL��'%/�./. z Uw ami Mwo o�w DRAWN J.V.H. CHECKED W.J.M. DATE OCT 21 2021 SCALE AS NOTED JOB NO. 2021-BROWN SHEET T-1 PLUMBING NOTES: 1. Domestic water piping shall be copper with wrought copper fittings. Close with a non -lead bearing solder. Insulate hot water piping with a minimum of 1" fiberglass insulation. 2. The owner shall select all plumbing fixtures and trim. 3. Plumbing contractor shall provide complete condensate system including 2" deep emergency drain pan under air handler for A/C system. Coordinate work with A/C contractor. 4. All vent, waste, and condensate lines shall be concealed in walls or under floor slab. 5. All water piping shall be type "L" copper. Vent and waste may be PVC where allowed by Florida Building code. 6. All plumbing fixtures shall have air chambers, and floor drains shall have trap primers. 7. Drawings are diagrammatic. Do not scale drawings for exact locations of equipment, piping, fixtures, etc. B. Contractor shall visit the job site and thoroughly familiarize himself with all existing conditions. 9. All required insurance shall be provided for protection against public liability or property damage for the duration of the work. 10. Verify location, size, and elevation for all existing utilities prior to beginning construction. Advice engineer of any discrepancies. 11. All materials shall be new as Shown. 12. All work shall be performed by a licensed plumbing contractor in a first class workmanlike manner. The completed system shall be fully operative and acceptance by owner must be a condition of the contract. 13. Soil, waste, and vent piping to be PVC schedule 40 DWV. Waste and vent piping above slab shall be PVC if approved by local authorities having jurisdiction. 14. All work shall be coordinated with other trades to avoid interference with the progress of construction. 15. All fixtures must be provided with readily available stops. 16. If dissimilar metals are to be joined approved insulation unions must be approved. 17. Any slab cuts and repair shall be by general contractor and included in his bid. 18. All fixtures shall be projected against water hammer with air chambers or shock absorbers as indicated on the plans. 19. Provide fully accessible cleanouts or sanitary and waste piping at every change of direction and at bottom of stacks. 20. Vent lines to extend 6" minimum above roof and flash with lead or connect to existing vent system. GENERAL NOTES: 1. THE STRUCTURE IS DESIGNED TO BE SELF-SUPPORTING AND STABLE AFTER THE BUILDING IS FULLY COMPLETED. IT IS SOLELY THE PLUMBING CONTRACTOR'S RESPONSIBILITY TO DETERMINE ERECTION PROCEDURE AND SEQUENCE AND TO INSURE THE SAFETY OF THE BUILDING AND ITS COMPONENT PARTS DURING ERECTION. THIS INCLUDES THE ADDITION OF WHATEVER SHORING, SHEETING, TEMPORARY BRACING, GUYS CONC. SLEAVES TIEDOWNS WHICH MIGHT BE NECESSARY. 2. IT IS SOLELY THE CONTRACTOR'S RESPONSIBILITY TO FOLLOW ALL OSHA APPLICABLE SAFETY CODES AND REGULATIONS DURING ALL PHASES OF CONSTRUCTION. 3. SHOULD ANY OF THE DETAILED INSTRUCTIONS SHOWN ON THE PLANS CONFLICT WITH THE GENERAL STRUCTURAL NOTES, THE SPECIFICATIONS OR WITH EACH OTHER, THE STRICTEST PROVISION SHALL GOVERN. 4, THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL DIMENSIONS AND ELEVATIONS SHOWN ON THE PLANS AND FOR COORDINATING ALL DIMENSIONS AND ELEVATIONS SHOWN ON THE ENGINEERING DRAWINGS. IF DISCREPANCIES IN THE DIMENSIONS OCCUR, IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO BRING THE DISCREPANCY TO THE ATTENTION OF THE ENGINEER BEFORE PROCEEDING WITH THE WORK. 5. Contractor shall ANCHOR "ALL HOT & COLD WATER LINES ELBOWS AND VALVES" TO PREVENT "WATER HAMMER" TYPICAL 6. All construction must meet the latest edtion, Florida Accessibility Code Requirements and the A.D.A. barrier free requirements. Latest edition 7. General Contractor shall coordinate and install all necessary backing supports for walls plumbing/lighting fixtures, Grab Bars, Hooks etc. 8. Contractor shall verify final selection of all finishes with Owner before proceeding with any work. g. All work shall be performed in accordance with the codes and/or regulations of ALL COUNTY, State of Florida, and all other codes, and/or regulations by any other authorities having jurisdiction over the work. 10. Contractor shall make no changes without written approval from the Engineer 11. Contractor shall INSULATE "ALL HOT WATER LINES ELBOWS AND VALVES" FROM ALL NEW H.W.H. SUPPLY TYPICAL A PROVIDE NEW S'DRAIN CLEAN OUT FOR NEW SINKS D.W. UNIT PROVIDE NEW 1/2" HOT & COLD WATER SUPPLY LINES TO NEW SINK/D.W. PROVIDE NEW 1/2"HOT COLD WATER SUPPLY LINE TO NEW SINK - VERIFY EXISTING OPENING ENCLOSED PORCH 9'-.4" CEIL. 28'-8" VERIFY INSIDE DIM. LIVING ROOM VAULT CEIL. STRUCTURAL_ BEAM ABOVE TO REMAIN FOYER VAULT CEIL: CNEW PROVIDE NEW DRAIN LINES SINKS PROVIDE NEW 1/2" COLD WATER SUPPLY LINE TO NEW W.C. EXISTING GROUND FL. A/C SYSTEM, WALLS TO BE REMOVED UNDER SEPARATE A/C PERMIT VERIFY/CAP ALL EXISTING DRAIN LINES VERIFY IN FIELD T. CL T. 6X6 NEW 2 PROVIDE NEW 1/2" HOT & COLD WATER SUPPLY LINES TO NEW z NEW SINK. SINK BATH N 9'-0" CELL. F z„ SINK & W.C. LOCATION VERIFY FLOOR SLAB 7 TUB II PROVIDE NEW 1/2" w COLD WATER SUPPLY HALL o r KITCHEN LINE TO NEW ICE. g'_0" CELL. a 2 BOWL 9'-0" VERIFY CEIL �� BATH SINK o� s'-o" CEIL. NEW �� oo" iv NEI � = NE1 SINK I o Ilo 4"STEP NEW Uj 71 13' 4" 6" 3'-4 11' 7" ERIFY FIE D INSTALL NEW 1 HOUR 6' UL CPHINET / HUTCH SEE Sll) DWG FIRE RATED 14'-10" NEW GARAGE 5'-4' CABINET / HUTCH SEE SHOP DWG PROVIDE NEW 1/2"' HOT & COLD WATER SUPPLY LINES TO NEW O WASHER NOTE: o VERIFY IN FIELD z_ 3 INSTALL NEW CUSTOM HUTCH SEE SHOP DWG ly BK NOOK W-O" CEIL. 1 CAR GARAGE 9'-0" VERIFY CEIL. EXISHNG MiL000R ,t NEW 170 D ZONE GARAGE DOOR 12'-0 NEW MASONARY OPENING W.C. DRAIN LINE FROM 2ND FLOOR THRU NEW ROOF TO EXISTING DRAIN LINES 3" V.T.R: VERIFY IN FIELD SEE SHEET P-2 \ UPPER FLOOR l n RELOCATE / REMOVE EXISTING 3" P.V.C. DRAIN LINE VERIFY LOCATION FROM 2ND FLOOR VERIFY/ CUT FLOOR SLAB AS REQUIRED FOR NEW DRAIN LOCATION CAP ALL EXISTING DRAIN PIPES TYP. REMOVE EXISTING SINKS, VERIFY LOCATION REPAIR FLOOR SLAB CAP ALL PIPES TYP. REMOVE 2"DRAIN LINE VERIFY LOCATION VERIFY FLOOR SLAB CAP ALL EXISTING PIPES FOR TUB REMOVED PROVIDE NEW 1/2" HOT & COLD WATER SUPPLY LINES TO NEW SINK - PROVIDE NEW 1/2" COLD WATER SUPPLY LINE TO NEW W.C. INSTALL NEW ELEC TANKLESS ON DEMAND ELEC W.H. SEE P-1 EXISTING 200 AMP PANEL REMOVE EXISTING W.H. NOTE: EXISTING SUPPLY LINES TO REMAIN SCALE.114! - T-0' 3,> THRU NEW ROOF 3" V.T.R. EXISTING 3" 4" C.O. 4 THRU NEW ROOF 3" V.T.R. THRU NEW ROOF 3" V.T.R. 3" 3" LAV. 3„ LAV. 3„ SINK VERIFY THRU ROOF W.C. 3" V.T.R. 3" 4 SINK 4 W.C. NEW / EXISTING PLUMBING SYSTEM GROUND FLOOR u 3„ y4" C.O. WASHER SINK 4 <4� TO EXISTING COUNTY DRAIN VERIFY IN FIELD PLUMBING RISER DIAGRAM LOWER LEVEL PLAN N.T.S. LIVING: 2,695 SF GARAGE: 300 SF COVERED PORCH: 275 SF COVERED ENTRY: 25 SF TOTAL: 3,295 SF TOTAL A/C 2,970 S.F. WOOD NOTE: ALL WOOD IN CONTACT WITH THE DECK METAL OR PLASTIC THAT SUPPORTS PERMANENT STRUCTURES INTENDED FOR HUMAN OCCUPANCY SHALL BE APPROVED PRESSURE TREATED WOOD ALL REPLACED WOOD SHALL BE P.T. SUITABLE FOR CONTACT USE. THIS IS IN COMPLIANCE PER 2020 FLORIDA BUILDING CODE 7TH EDITION REF. DISSIMILAR MATERIALS CONTACT. NOTE: 1. SEE AMERICAN STANDARD SPEC'S FOR MANUFACTURERS NUMBERS FOR TOILET ACCESSORIES. 2. ALL TOILET PAR71TIONS SHOWERS DIMENSIONS ARE CENTER LINE OF PARTITION. (WHEN USED) 3. CONTRACTOR TO USE PLYWOOD BACKING BOARD FOR ALL NEW GRAB BARS, SHELVES & ACCESSORIES TYPICAL VIE NOTE: Contractor is responsible for bracing of PLUMBING Structure during construction. All measurements to be verified by contractor prior to start of job. All Hardware, SINKS FIXTURES CHOSEN BY OWNER NOTE: THESE PLANS AND ALL ASSOCIATED DOCUMENTS ARE VALID FOR CONSTRUCTION ONLY UPON STAMPED APPROVAL FROM APPROPRIATE GOVERNING JURISDICTION. THESE PLANS ARE VOID AND SHALL NOT BE USED FOR CONSTRUCTION OR ANY OTHER PURPOSE WITHOUT BUILDING DEPARTMENT REVIEW AND APPROVAL. w a Fa oLL 00 �a o= U�- 0 o� aw w U a� �w o ,n ow U� w� m� w o� z� W �z a- F 00 z� as ww a� or mz N a O 0o O c 3a I o �0 00 q) w a o N 0 p z oz y 0 iw N w m� z o= O a OL o zo � a z4 r X 3 Q� 0) �o O � N o = d�- F� wM ow X J o �z o� aw wF rn � Q % o M zs NV) w 00 N a� w� U w o� �z a� I� �o zw w a� oa ow Wa w DI m a 1-. g N / 7 56 r� UO ® �1 on a� Foo M r, UI O Z F-+-I o� Z a w � W g wog N zao pro zrr ^y air w oz wa g<� >�o r« a rya ooa woz ao LO1^ wzz U>a3 u✓ N � wz> 0 rya U U <Zm aza oa x JUI m d U U QWILLIAM J. MATHERS, PE FL # 19658 FZo F T U �ma Fain # w o TATE OF ,o O k ,` zoo • .c ' a wo // � •i. w i RAT ONLY �zw U aW U U - w a m I ' W O O S o`o uww p-U W F o Z ' �0gw so awe 0 0Q Vow H J d �LL W �wg W�a w aW Qzz uo zz Ows U Z I- a DRAWN J.V.H. CHECKED W.J.M. DATE DEC 2021 SCALE AS NOTED JOB NO. 2021-BROWN SHEET P - I PLUMBING PLAN UPPER LEVEL NEW PROVIDE NEW 1/2" HOT & COLD WATER SUPPLY LINE TO NEW SINK PROVIDE NEW 2" PVC DRAIN LINES FOR NEW SINKS PROVIDE NEW 3"drain & CLEAN OUT FOR NEW SHOWER DRAIN PROVIDE NEW 1/2" HOT & COLD WATER SUPPLY LINE TO NEW SHOWER PROVIDE NEW 1/2" COLD WATER SUPPLY LINE TO NEW LAV. PROVIDE NEW 3" PVC DRAIN LINES FOR NEW W.C. SCALE-1/4' = T-0' THRU NEW ROOF THRU NEW ROOF 3" V.T.R. W ROOF TO EXISTING DRAIN system VERIFY IN FIELD SEE P-1 FOR LOWER LEVEL RISER PLUMBING RISER DIAGRAM UPPER FLOOR NEW N.T.S. WOOD NOTE: ALL WOOD IN CONTACT WITH THE DECK METAL OR PLASTIC THAT SUPPORTS PERMANENT STRUCTURES INTENDED FOR HUMAN OCCUPANCY SHALL BE APPROVED PRESSURE TREATED WOOD ALL REPLACED WOOD SHALL BE P.T. SUITABLE FOR CONTACT USE. THIS IS IN COMPLIANCE PER 2020 FLORIDA BUILDING CODE 7TH EDITION REF. DISSIMILAR MATERIALS CONTACT. NOTE: 1. SEE AMERICAN STANDARD SPEC'S FOR MANUFACTURERS NUMBERS FOR TOILET ACCESSORIES. 2. ALL TOILET PARTITIONS SHOWERS DIMENSIONS ARE CENTER LINE OF PARTITION. (WHEN USED) 3. CONTRACTOR TO USE PLYWOOD BACKING BOARD FOR ALL NEW GRAB BARS, SHELVES & ACCESSORIES TYPICAL VIF. NOTE: Contractor is responsible for bracing of PLUMBING Structure during construction. All measurements to be verified by contractor prior to start of job. All hardware CHOSEN BY OWNER NOTE: THESE PLANS AND ALL ASSOCIATED DOCUMENTS ARE VALID FOR CONSTRUCTION ONLY UPON STAMPED APPROVAL FROM APPROPRIATE GOVERNING JURISDICTION. THESE PLANS ARE VOID AND SHALL NOT BE USED FOR CONSTRUCTION OR ANY OTHER PURPOSE WITHOUT BUILDING DEPARTMENT REVIEW AND APPROVAL. r� w 0 Fa �o ou rw <w ow zc cLL z CL 1 J w U mm o� o� �o �w w` mw o� z� w �z x- xw mx 00 zw a' - a ww rc }U ww c c Qw z: a� } m �z W� �a oz 0 wn cc Qo 0 00 z_ a cw oz Tw z �w m� W W� a� 0 �o z �z zw wo �a z az xQ 00 Fd _w jo 0 �w W? oz NW zz a aw IN I ow }= �4 z� ow C6o w �o r_- w� zw oa U Z Q� 13 �o rW �f a� ox U W N Lo O O I a o 00 W ire N N a r � O z 2 Z v D o � } S m 10 W M X � V Ld 0 � U V7 (1) FT-4 W 11L.W���� Y Z r1 W z I a W a 0 0 rFr� FT-1 WILLIAM J. MATHERS, PE FL'# 19658,' t: DRAWN J.V.H. CHECKED W.J.M. DATE OCT 2021 SCALE AS NOTED JOB NO. 2021— BROWN SHEET P 2 W ELECTRICAL NOTES: Electrical Contractor shall supply and install all new electrical work indicated. Construction shall be in accordance 1. with drawings and applicable specifications. If a problem is encountered in complying with this requirement, contractor shall notify the owner or his representative as soon as possible after discovery of the problem and shall not proceed with that portion of the work until owner has directed corrective action to be taken. 2. Electrical contractor shall visit job site and familiarize himself with all conditions affecting electrical and communications installation and make provisions as to the cost thereof. Existing conditions of electrical equipment, light fixtures, etc. that are part of the final system shall be verified by the contractor prior to submitting his bid. FLORIDA BUILDING CODE 2020 7th EDITION Ordinances of the authority having jurisdiction. 3. Do not scale the electrical drawings. 4. Refer to FLOOR plans and elevations for exact location of all equipment. Confirm with owner's representative. 5. Minimum wire size shall be # 12 A.W.G. excluding control wiring. Unless otherwise noted, all conductors shall be copper with THHN insulation. 6. Outlet boxes shall be pressed steel in dry locations, cast alloy with threaded hubs in wet or damp locations and special enclosures for all other classified areas. 7. It is not the intent of these plans to show every minor detail of construction. The contractor is expected to furnish All work shall be performed in accordance with the latest edition of the National Electrical Code and Florida Building codes and placed in proper working order. 8. Electrical system shall be complete and effectively grounded as required by the latest edition of the NEC or local codes. All equipment shall be new and bear Underwriters labels where applicable, unless noted otherwise. 9.AII work shall be performed by a licensed electrical contractor in a first class workmanlike manner. 10.The completed system shall be fully operative and accepted by the Engineer All work shall be coordinated with other trades to avoid interference with the progress of construction. 11. Provide and install all items for a complete electrical system and provide all trim, accessory requirements necessary for equipment to be operational. 12. Contractor shall guarantee all new materials and workmanship free from defects for a period of not less than (1) one year from date of acceptance. 13. Correction of cry defects shall be completed without additional charge and shall include replacement or repair of any other phase of the insulation which may have been damaged thereby. 14. All required insurance shall be provided for protection against public liability and property damage for the duration of the work. 15. Contractor shall pay for all permits, fees, inspections and testing. Contractor to obtain permit and approved submittals prior to beginning work or ordering equipment. 16. The electrical installation shall meet all standard requirements of power and telephone companies. 17. Contractor shall coordinate with mechanical drawings and provide all necessary ELEVATOR control wiring. 1& All circuit breakers feeding mechanical equipment shall be HACR type circuit breakers. 19. Provide and install conduit, conductors, pull wires, cover plates, devices, etc. for all outlets as indicated. 20. Materials, products, and equipment, including all components thereof, shall be new and such as appear on the UL list of approved items and shall meet or exceed the requirements of NEC, NEMA, and IECE latest editions. 21 Contractor shall submit drawings or cut sheets of lighting fixtures, switches, and other electrical items for approval BY OWNER 22. Contractor shall be responsible for all cutting and patching required of his work. 23. Electrical contractor shall label all panels with typewritten directories 24. All light switches to be at 42" AFF. 25. All electrical wiring shall be the responsibility of the electrical contractor. All electrical wiring for the HVAC system including controls, thermostats, power, etc. shall be the responsibility of the electrical contractor. 26. Panelboards: All current carrying buses shall be copper. All ground bus bars shall be copper. Panelboard enclosures shall be furnished without pre -punched concentric holes. A.I.C. ratings shall be as indicated on panelboard schedules. 27. Disconnect switches shall be H.P. rated, heavy duty, quick -make, quick -break enclosures as required by exposure. 28. Motor starters shall be manual or magnetic, with overload relays in each hot leg. 29. Contractor shall confirm with FPL any and all requirements such as: lug size restrictions, conduit entry, transformer size, scheduled down time for owners confirmation, etc. Any conflicts shall be brought to attention of the engineer before proceeding with any work. 30. ALL EXTERIOR OUTLETS AND NEW OUTLETS IN THE EXISTING GARAGE, KITCHEN AND BATHROOMS AND ALL EXTERIOR LIGHTS, OUTLETS ARE TO BE GFI PROTECTED. W/ ARC -FAULT CIRCUIT INTERRUPTION PROTECTION TYP. AR M i\ r MASTER SUITE " CEIL 9 - L AR \ / l A AR (C9 SD CUSTON SHELF SYSTEM Gn w° M CLOSET SINK INK IL HA \ r \ r VAULT IL M B H VAULT CEIL. i 36" S.C. / W abr O CUSTON SHELF SYSTEM CLOSET o 3'-5 5' 3" AR I T� OSET \ 8'-4" CEIL. 0 VP � SHO 1 DD I TE: VAT UND RATE EXISTING P IT / SPIRAL STAIR EXISTING 36" AIUNG TO REMAIN VERIFY I r r OP N LOF VAULTE CEIL 8•-4" 3EIL \ AFI \ .U. AHU ATTIC ♦r Al i EXIST CLOSET I AR A ACCESS w C. LT. „� aosEr 2668 WOOD AR sD EXIST DOOR 1 1 / A UNDRY N / \ CLOSET 5D INSTALL NEW i%4 STUD STAG( WALLS W/ 5/S' DRYWALL ED OOM 2 SD -0" CEIL. \ r r N AH r m w a BATH 8. 8'-0" 1V � r:vp:� An EGRESS WINDOW EGRESS WINDOW MA m C 5 EE R PAD 'YPE, ARATE LD TYP. LL NKLESS EMAND W.H. SEE CIRCUIT 1,FS POLE/BREAKER LOAD WIRE SIZE 1,3 A/C SYSTEM CONDENSER #1 2P/40A (3.8 KW) #8 2,4 A.H.U. / HEAT STRIP #1 2P/60A (9.5 KW) #6 5,7 A/C SYSTEM CONDENSER #2 2P/40A (3.8 KW) #8 6,8 A.H.U. / HEAT STRIP #2 2P/60A (9.5 KW) #6 9,11 RANGE 2P/50A 12.0 KW #6 10,12 DRYER 2P/30A 5.0 KW #10 13 MICROWAVE 1P/20A 1.2 KW #12 14 WASHER -LAUNDRY 1P/20A 1.5 KW #12 15 REFRIGERATOR 1P/20A 1.2 KW #12 16 DISHWASHER 1 P/20A 1.0 KW #12 17 DISPOSAL 1P/20A 0.7 KW #12 18 SMALL APPLIANCES 1 P/20A 1.5 KW #12 19 SMALL APPLIANCES 1P/20A 1.5 KW #12 20 SMALL APPLIANCES 1 P/20A 1.5 KW #12 GEN. LIGHTING, RECEPTACLES, 9.0 KW - (6) CEILING FANS ® .15 EA. 0.9 KW - 21-33 (2) EXHAUST FANS 0 .8 EA. 1P/15A 2.4 KW #14 (10) HI -HATS ® .07 EA. 1.0 KW - - 1.8 KW - ALARM SYSTEM 1.2 KW - 34,35 SPARES - TOTAL LOAD (WITHOUT HVAC) 42.4 KW GENERAL LIGHTING CALC. FOR 2790 S.F. x 3 WATTS/SQ. FT. = 2900 6.0 KW ELECTRICAL SERVICE CALCULATION (PER SECTION 220-30 N.E.C.) A.H.U. / HEAT STRIP 0 100% = 19.0 KW FIRST 10.0 KW ® 100% = 10.0 KW REMAINDER ® 40% (33.4 x .40) = 33.4 KW ELEVATOR 20 AMP TOTAL COMPUTED LOAD = 62.4 KW KW'S x 1000 w = 260 AMPS PROVIDE 300 AMP SERVICE 240 VOLTS (3) #2/0 THHN-CU IN 3" CONDUIT ELECTRICAL LEGEND DUPLEX RECEPTACLE GFI GROUND FAULT INDICATOR WP /WATER PROOF QUAD RECEPTACLE & 230 VOLTS ® SPECIAL OUTLET - SWITCH A -0 4 4 WAY SWITCH -� 3 3 WAY SWITCH INCANDESCENT LIGHT RECESSED LIGHT \ / vp VAPORI PROOF S*ItHED OUTLET i RECESSED LIGHT \ r (EYEBALL) Qi FLOOR OUTLET HOLLYWOOD-STYLE o n cn24 STRIP LIGHTING ELECTRIC METER BY 0 FLORIDA POWER & LIGHT 300 AMP 1PH. 300 AMP 3W, 115/230V METER FLUSH MOUNTED NEMA 1 W/ 300 AMP MAIN BREKER TRANSFORMER BY FLORIDA POWER & E L E C T RI C A K FLOOD LIGHTS E]TV TELEVISION OUTLET PH PHONE OUTLET ® EXHAUST FAN -� pg POWER BUTTON 0000 RBELL CHIMES c sD SMOKE DETECTOR CLG. MOUNT Carbon Detector combo sD SMOKE DETECTOR WALL MOUNT !� JUNCTION BOX J CEILING FAN (OUTLET ONLY) LJ U TRACK LIGHTING F-� FLUORESCENT FIXTURE OPTIONAL 31 AMP MAIN DISCONNECT NOTE:100 AMP TO BE USED FOR NEW ADDITION „A" EXISTING PANEL (3) #2/0 THHN-CU IN 2" CONDUIT 00 AMP „B„ NEW PANEL #4 SOLID OR STRAND CU. GROUND TO #5 REINFORCING BARSAT FOUNDATION BASE COLD WATER PIPE R I S E R D I A G R A M N.T.S. W W MW w E-1 co Q Z Iwo > W H Z C) U W F4 W W o V 1 ��II NN 46 rE-1LO H FJ--I EC .-I W'bU zF� Q=z _ m Leo z�n W� U � Paz WOOD NOTE: ALL WOOD IN CONTACT WITH THE DECK METAL OR PLASTIC THAT m SUPPORTS PERMANENT STRUCTURES INTENDED FOR HUMAN OCCUPANCY SHALL a BE APPROVED PRESSURE TREATED WOOD ALL REPLACED WOOD SHALL BE ELECTRICAL UPPER LEVEL PLAN ELECTRICAL PLAN LOWER LEVEL M P.T. SUITABLE FOR CONTACT USE. THIS IS IN COMPLIANCE PER 2020 FLORIDA SCALE 1/4 ® 1-0 SCALE: 1/4 - 1-O BUILDING CODE 7TH EDITION REF. DISSIMILAR MATERIALS CONTACT f } ■ - f p E. . NOTE: o-� mom wza THESE PLANS AND ALL ASSOCIATED DOCUMENTS ARE VALID FOR CONSTRUCTION N ONLY UPON STAMPED APPROVAL FROM APPROPRIATE GOVERNING JURISDICTION. THESE PLANS ARE VOID AND SHALL NOT BE USED FOR CONSTRUCTION OR ANY L OTHER PURPOSE WITHOUT BUILDING DEPARTMENT REVIEW AND APPROVAL. 0 zW� wwa wog^ w z�r aL� -w zz wo O w os< zee ELECTRICAL NOTE: ALL EXTERIOR OUTLETS AND OUTLETS IN THE BASEMENT, GARAGE, KITCHEN AND BATHROOMS ARE TO BE GFI PROTECTED. ALL LIGHT SWITCHES THAT OPERATE LIGHTS THAT ILLUMINATE STAIR AREAS SHALL BE ILLUMINATED LIGHT SWITCHES. ALL OUTLETS INSTALLED IN KITCHEN ISLANDS SHALL BE INSTALLED PER NEC 210-52 ARC -FAULT CIRCUIT INTERRUPTION PROTECTION SHALL BE PROVIDED IN ALL BEDROOMS. DRAWN J.H. CHECKED J.H. DATE 12/21/21 SCALE AS NOTED JOB NO. 2021 BROWN SHEET E-1