HomeMy WebLinkAboutMechanical Floor PlanA/C O A/C O MECHANICAL NOTES: ALTERATION GENERAL NOTES: 1. Mechanical contractor shall furnish controls and wiring diagrams to electrical 7_ Upon completion of work the system shall be tested and balanced. contractor and coordinate installation. All equipment shall have proper vibration isolators. 1 REMOVAL OF THE EXISTING IMPROVEMENTS SHALL BE AS REQUIRED FOR 2. Mechanical contractor shall furnish engineered duct layout showing duct sizes and Supply & return shall be 24x24" lay in grills. TYP. THE PROJECT. THE MATERIALS REMOVED FROM THE SITE SHALL BE DISPOSED C.F.M. requirements. Any information shown in this set is schematic & to be OF IN A PROPER AND LEGAL MANNER PER FEDERAL, STATE, AND OR LOCAL used as a guide only. The final duct layout shall be completed by contractor for Building dept. 8. A/C subcontractor shall review the energy calculations and provide equipment which LAWS AND ORDINANCES. complies with the E.E.R. shown, and install any heat recovery units which are 3. All work shall be done in accordance with all state and local codes and ordinances in 2 EXISTING BUILDING ADDITIONS, WALLS FLOORS CEILINGS ELECTRICAL PIPES the best workmanlike manner. 9. Contractor shall visit the site and familiarize himself with all existing conditions STRUCTURES, TO REMAIN SHALL BE PROTECTED FROM DAMAGE BY THE necessary or requested by the owner. VERIFY EXISTING EQUIP. CONTRACTOR. ANY DAMAGE DURING CONSTRUCTION SHALL BE RESTORED, 4. Ductwork shall be R-6.2, 1 1/2" ridge foil backed fiberglass code 90 designed, RECONSTRUCTED OR REPLACED BY THE CONTRACTOR AT HIS EXPENSE. ALL fabricated, and installed, in accordance with A.S.H.R.A.E. Guide and FL state and 10. All work shall be coordinated with other trades to ovoid interference with the DAMAGES SHALL BE RESTORED OR REPLACED TO AT LEAST THEIR ORIGINAL - i f' Z X local codes. before proceding with the work. CONDITION OR AS REQUIRED OR DICTATED BY FEDERAL, STATE, COUNTY, - CITY OR LOCAL GOVERNING AGENCIES. ANY UTILITIES REQUIRED TO REMAIN N j /n9 4r!y (�- 5. Coordinate installation of condensate system with plumbing contractor. Condensate IN SERVICE FOR EXISTING BUILDING ADDITIONS TO REMAIN SHALL BE ENCLOSED PORCH system shall include a 2" deep emergency pan w/ emergency cut-off float switch 11 All work shall be DRAWN AS A "AS BUILT HVAC DUCT, EQUIP LINES DRAINS TYP. PROTECTED. v 9'-4" CEIL under air unit. TO SHOW Progress of ALL HVAC Construction. 3 IT IS THE RESPOSIBILITY OF THE CONTRACTOR TO INSPECT EACH DAY AND f 6. The REMOVE ALL MUD, DIRT, GRAVEL AND LOOSE MATERIALS TRACKED, DUMPED, f mechanical contractor shall submit engineered shop drawings that comply with SPILLED OR WIND BLOWN FROM THIS SITE ONTO OTHER SITES, RIGHT OF Florida energy code for COUNTY permitting and owner's approval. WAYS, PUBLIC OR PRIVATE STREETS OR ROADS, DRIVEWAYS, YARDS OR SIDEWALKS. THE CONTRACTOR MUST CLEAN OR PICK UP DAILY IF NECESSARY. 0 VERIFY EXISTING OPENING 28'-8" VERIFY INSIDE f 12-'L p e'- iv rc w FOYER VAULT CEIL d '!frw EXISTING GROUnD FL A/C SYSTEM, WALLS TO BE REMOVED UNDER SEPARATE A/C PERMIT VERIFY/CAP ALL EXISTING DRAIN LINES VERIFY IN FIE KITCHEN 2 SBNK L 9 -0" VERIFY CEIL. 13' H4" 'AULT CEIL. 12°°,9\ NEW P.T. 6XP—NEW P.T. 6X6 SPIRAL STAIR TO REMAIN N I i� 601, a= ,' A I (�b BATH e��:': SINK & W.C. LOCATION VERIFY FLOOR SLAB rvz 0 Y 0 � � m CEIL / 07-7 ' �`8 I 6 7 W5 BATH 2 taTt �LL '-o" CEILHA0CEIL "o'�� v SEES MG� ;- 7- .. _.. h 5'-4" 1 SEE wc�"FT 3 l L N i �t l pYrO: BK NOOK LU t'rFIs W 9'-0" CEIL MTL DOOR I) ih 1 CAR GARAGE 9'-0" VERIFY CEIL NEW 170 D ZONE GARAGE DOOR NOTE:NEW WD-9500 ELEVATOR SEE LOWER LEVEL PLAN FOR ELEVATOR PAD LOCATION & PLAN DETAILS SEE ELEVATOR SHOP DRAWINGS FOR TYPE, ELECTRICAL CONNECTIONS, MODEL SPECIFICATIONS- ALL UNDER SEPARATE STATE FLA PERMIT -VERIFY IN FIELD TYP. INSTALL NEW ELEC TANKLESS ON DEMAND ELEC W.H. SEE P-1 EXISTING ELEC PANEL MECH PLAN UPPER LEVEL SCALE 1/47 - T-O' — SCALE: /4' -1'-O' 4 IT IS THE CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE OWNER AND ALL THE UTILITY COMPANIES AND DEPARTMENTS. VERIFY THAT UTILITIES HAVE BEEN DISCONNECTED AND CAPPED BEFORE STARTING DEMOLITION OPERATIONS. 5 IT IS THE RESPONSIBILITY OF THE CONTRACTORS TO OBTAIN ALL FEDERAL, STATE, COUNTY, CITY, AND LOCAL PERMITS FOR ANY AND ALL WORK REQUIRED UNLESS OTHERWISE NOTED. THIS SHALL INCLUDE ALL SUBMITTALS AS REQUIRED INCLUDING STORMWATER RUNOFF CONTROL. THE CONTRACTOR OR CONTRACTORS ARE RESPONSIBLE TO PAY FOR ALL REQUIRED PERMITS BY ANY OR ALL AGENCIES MENTIONED ABOVE UNLESS OTHERWISE NOTED BY THE CONTRACTOR OR SPECIFICATIONS. 6 THE CONTRACTOR MUST VISIT THE SITE AND STUDY EXISTING PHYSICAL BUILDING CONDITIONS, REVIEW EXISTING DRAWINGS, AND REACH THEIR OWN CONCLUSIONS ON WORK NECESSARY TO ACCOMPLISH INTENDED RESULTS DESCRIBED BY THE PROJECT DOCUMENTS. 7 ALL PIPES AND CONDUITS IN WALLS THAT ARE TO BE DEMOLISHED ARE TO BE REMOVED AND/OR RELOCATED AS REQUIRED. 8 JOBSITE INSPECTION MUST BE CONDUCTED TO EXAMINE EXISTING ROOF WALL, CONDITIONS, TO DETERMINE NATURE AND SCOPE OF WORK OR ANY DIFFICULTIES THAT MIGHT ARISE AT TIME OF WORK. IN ADDITION, EXAMINE ALL WORK THAT IS INTENDED TO REMAIN AS PART OF THE COMPLETED PROJECT AND REPORT ALL UNSATISFACTORY CONDITIONS TO OWNER PRIOR TO COMMENCEMENT OF WORK. EXERCISE EXTREME CARE DURING DEMOLITION SO AS NOT TO DAMAGE CONSTRUCTION AND OTHER STRUCTURES THAT ARE INTENDED TO REMAIN. ANYTHING DAMAGED AT TIME OF WORK IS TO BE REPAIRED AND/OR REPLACED TO MATCH EXISTING CONSTRUCTION AT CONTRACTORS EXPENSE. COMMENCE WITHIN EASEMENTS ON ADJACENT PROPERTIES UNTIL A CORONATION MEETING HAS BEEN HELD BETWEEN THE CITY, SCHOOL CORP, REPRESENTATIVE, ARCHITECT AND ADJACENT PROPERTY OWNERS. 9 UTILITY SERVICE: MAINTAIN EXISTING UTILITIES INDICATED TO REMAIN IN SERVICE AND PROTECT THEM AGAINST DAMAGE DURING SELECTIVE DEMOLI1ON OPERATIONS. 10 ALL EXISTING SERVICES, MECHANICAL, ELECTRICAL, AND PLUMBING, SHALL REMAIN IN CONTINUOUS OPERATION THROUGHOUT THE ENTIRE CONSTRUCTION PROCESS. IF IT BECOMES NECESSARY TO SHUT DOWN ANY OF THESE SERVICES, THE OWNER SHALL BE NOTIFIED, AS IDENTIFIED IN THE SPECIFICATIONS, BY THE CONTRACTOR. System #1: Tempstar CU Model #: N4A736GKA AH Model #: FVM4X4800BL Stages: Two Heater# EHK05AKB 5 KW SEER 16 EER 13 Note 1: Duct design may vary because existing conditions. Note 2: If existing electrical conditions DFRONT allow and the HOA agrees, the condensing units will be moved further towards the front. Kevin M. Sharkey Sharkey Air LLC Lie # CAC049289 Lie # CAC1816853 j 'J AREA CALCULATIONS LIVING: 2,695 SF GARAGE: 300 SF COVERED PORCH: 275 SF COVERED ENTRY: 25 SF TOTAL: 3,295 SF FOTAL A/C 2,970 S.F NOTE: LIVING: A/C space 2970 SF THESE PLANS AND ALL ASSOCIATED DOCUMENTS ARE VALID FOR CONSTRUCTION ONLY UPON STAMPED APPROVAL FROM APPROPRIATE GOVERNING JURISDICTION. THESE PLANS ARE VOID AND SHALL NOT BE USED FOR CONSTRUCTION OR ANY OTHER PURPOSE WITHOUT THE M.C. HEALTH DEPARTMENT REVIEW AND APPROVAL OF JUNE 2021 1.4 � U W Q E-, �W H � W W n w za -yTs' 25/Z A/C- MECH ONLY DRAWN JR CHECKED W.J.M. DATE NOV 21 2021 SCALE AS NOTED JOB NO. 2021-BROWN SHEET M-1