HomeMy WebLinkAboutNOA Concrete Roof Tile,
M IAM I•DADE
n MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy
Boral Roofing, LLC
7575 Irvine Center Drive, Suite 100
Irvine, CA 92618
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product
or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is
determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Boral Villa 900 Concrete Roof Tile
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA_number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA# 21-0420.02 and consists of pages 1 through 7.
The submitted documentation was reviewed by Alex Tigera.
tl 14,1(1A
NOA No.: 21-0712.03
Expiration Date: 09/21/26
Approval Date: 09/16/21
Page 1 of 7
0
3
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub Category: Roofing Tiles
Material: Concrete
1. SCOPE
This renews a system using Boral Villa 900 Concrete Roof Tile, as manufactured Boral Roofing, LLC in Lake Wales,
FL and described in Section 2 of this Notice of Acceptance. For locations where the pressure requirements, as determined
by applicable Building Code, do not exceed the design pressure values obtained by calculations in compliance with RAS
127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system.
2. PRODUCT DESCRIPTION
Manufactured by
Test
Applicant Dimensions
Specifications
Boral Roofing Villa 900 Length =17"
TAS 112
Width = 13"
Type 1 b
''V? thick
Class III
Trim Pieces 1= varies TAS 112
w = varies
varying thickness
2.1 PRODUCTS MANUFACTURED BY OTHERS
Product Name
ICP Adhesives Polyset® AH-160
TILE BONDTM Roof Tile Adhesive
"Tile Tite" Roof Tile Mortar
Touch `N Seal StormBondo 2 Two -
Component Polyurethane Roof Tile
Adhesive
Product Description
Product
Description
Low profile, interlocking, high pressure extruded
concrete roof tile equipped with three nail holes
and double rolls. For direct deck, batten, mortar
or adhesive set applications.
Accessory trim, concrete roof pieces for use at
ridges, hips and rakes.
Two component polyurethane
foam adhesive.
Single component polyurethane
foam roof tile adhesive.
Premixed, pre -bagged roof tile
mortar.
Two component polyurethane
foam adhesive.
Touch `N Seal StormBone One One component polyurethane
Component Polyurethane Roof Tile foam adhesive.
Adhesive
2.2 MANUFACTURING LOCATION
2.2.1. Lake Wales, FL
i so
�GMAPMPROMVED
Manufacturer
(With Current NOA)
ICP Adhesives and Sealants, Inc.
DuPont de Nemours, Inc.
Bermuda Roof Co. Inc.
DAP Foam, Inc.
DAP Foam, Inc.
NOA No.: 21-0712.03
Expiration Date: 09/21/26
Approval Date: 09/16/21
Page 2 of 7
0
2.3 EVIDENCE SUBMITTED
Test Agency
Test Identifier
Nutting Engineers
13343.1
Redland Technologies
7161-03
Appendix III
7161-03
Appendix II
P0402
The Center for Applied 94-060B
Engineering, Inc.
.94-084
Redland Technologies
The Center for Applied
Engineering, Inc.
Celotex Corporation
Testing Services
Walker Engineering, Inc.
American Test Lab of South
Florida
P0631-01
Letter Dated Aug. 1, 1994
Project No. 307025
Test #MDC-76
25-7183-1
25-7183-2
25-7214-2
25-7214-6
528454-2-1
520109-2
Evaluation Calculations
Evaluation Calculations
Evaluation Calculations
Evaluation Calculations
Evaluation Calculations
Evaluation Calculations
Evaluation Calculations
RT0617.02-16
RT0503.02-21
Test Name/Reaort
TAS 112
Static Uplift Testing
TAS 102 & TAS 102(A)
Wind Tunnel Testing
TAS 108 (Nail -On)
Withdrawal Resistance Testing of
screw vs. smooth shank nails
Static Uplift Testing
TAS 101 (Adhesive Set)
Static Uplift Testing
TAS 101 (Mortar Set)
Wind Tunnel Testing
TAS 108 (Mortar Set)
Wind Tunnel Testing
TAS 108.(Nail-On)
Wind Driven Rain
TAS 100
Static Uplift Testing
TAS 102
(2 Quik-Drive Screws, Direct Deck)
Static Uplift Testing
TAS 102
(1 Quik-Drive Screw, Direct Deck)
(1 Quik-Drive Screw, Battens)
Static Uplift Testing
TAS 101
25-7183
25-7094
25-7496
25-7584
25-7804b-8
25-7804-4 & 5
25-7848-6
Aerodynamic Multipliers
Two Patty Adhesive Set System
Restoring Moment Due to Gravity
TAS 112
TAS 112
Date
Apr. 2006
Dec. 1991
Dec. 1991
Sept. 1993
March, 1994
May 1994
July 1994
Aug. 1994
Oct. 1994
Feb. 1995
March, 1995
Sep. 1998
Dec. 1998
March 1995
February 1996
April 1996
December 1996
09/01/16
April 1999
09/01/16
06/29/16
05/12/21
NOA No.: 21-0712.03
Expiration Date: 09/21/26
Approval Date: 09/16/21
Page 3 of 7
a
PRI Construction Materials COPO-002-02-11
Static Uplift Testing
10/12/2016
Technologies
TAS 101 (Adhesive Set)
COPO-002-02-04
Static Uplift Testing
10/12/2016
TAS 101 (Adhesive Set)
COPO-002-02-03
Static Uplift Testing
10/12/2016
TAS 101 (Adhesive Set)
2002T003.02
TAS 101
11/06/20
NEMO ETC, LLC 4c-DPBS-20-LSOTM-01.C.R1 TAS 101 12/17/20
3. LIMITATIONS:
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with TAS
106.
3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in
accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code Compliance Office
for review.
3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section
4.1 herein.
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated
otherwise by the underlayment material manufacturers published literature.
3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable
building code.
4. INSTALLATION
4.1 Villa 900 Concrete Roof Tile and its components shall be installed in strict compliance with Roofing Application
Standard RAS 118, RAS 119, and RAS 120.
4.2 Data For Attachment Calculations
Table 1: Average Weight (W) and Dimensions (I x w )
Tile Profile
Weight-W (Ibfl
Length -I (ft)
Width-w (ft)
Villa 900 Concrete Tile
10.90
1.42
1 1.08
Table 2: Aerodynamic Multipliers - X (ft3)
Tile Profile
X (ft3)
Batten Application
(ft3)
Direct Deck Application
Villa 900 Concrete Tile
0.291
0.315
NOA No.: 21-0712.03
Expiration Date: 09/21/26
Approval Date: 09/16/21
Page 4 of 7
Table 3: Restoring Moments due to Gravity - M9 (ft.-Ibf.)
Tile Profile
2":12"
3":12"
4":12"
5":12"
6":12"
7":12" or greater
Villa 900
Concrete Tile
Direct
Deck
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
Battens
Direct
Deck
7.70
7.62
6.56
7.50
6.42
7.34
6.26
7.15
6.08
6.95
Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-lbf)
for Mechanically Fastened Systems
Tile Profile
Fastener Type
Direct Deck
Direct Deck
Battens
(min 16132" plywood)
(min.19/32" plywood)
Villa 900
2-10d Ring Shank Nails
27.8
37.4
28.8
Concrete Tile
1-10d Smooth or Screw
8.8
11.8
4.1
Shank Nail
2-10d Smooth or Screw
16.4
21.9
7.1
Shank Nails
1 #8 Screw
25.8
25.8
22.9
2 #8 Screw
47.1
47.1
49.1
1-10d Smooth or Screw
24.3
24.3
24.2
Shank Nail Field Clip)
1-10d Smooth or Screw
19.0
19.0
22.1
Shank Nail Eave Clip)
2-10d Smooth or Screw
35.5
35.5
34.8
Shank Nails Field Clip)
2-10d Smooth or Screw
31.9
31.9
32.2
Shank Nails Eave Clip)
Table 5: Attachment Resistance Expressed as a Moment Mf (ft-lbf)
for Two Paddy Adhesive' Set Systems
Tile Profile
Tile Application
Minimum Attachment
Resistance
Villa 900 Concrete Tile
TILE BONDTm Roof Tile Adhesive
352
TILE BONDTm Roof Tile Adhesive
673
ICP Adhesives Pol set® AH-160
26.14
Touch 'N Seal StormBond02
555
Touch 'N Seal StormBond® (one component)
725
1 See foam adhesive manufacturer's component approval for installation requirements.
2 Medium paddy weight of 8 grams per paddy of TILE BONDTm Roof Tile Adhesive
3 Medium paddy weight of 16 grams per paddy of TILE BONDTm Roof Tile Adhesive
4 Medium paddy weight of 8 grams per paddy of Polyset® AH-160
5 Medium paddy weight of 8 grams per paddy of Touch 'N Seal StormBond ® 2
6 Medium paddy weight of 8 grams between tile and underlayment, paddy weight of 5 grams on
overlap of tile of
Touch 'N Seal StormBond ® one component)
NOA No.: 21-0712.03
MIAMI•DAD; COUNTY Expiration Date:09/21/26
-0712.03
Approval Date: 09/16/21
Page 5 of 7
Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-lbf)
for Single Paddy Adhesive Set Systems
Tile
Tile Application
Minimum Attachment
Profile
Resistance
Villa 900 Concrete Tile
ICP Adhesives Polyset@ AH-160
86.67
ICP Adhesives Polyset@) AH-160
45.511
Touch'N Seal StormBond®2
409
Touch 'N Seal StormBond®2
7010
7 Large paddy weight of 54 grams of Polyset@ AH-160
8 Medium paddy weight of 24 grams of Polyset@ AH-160
9 Medium paddy weight of 30 grams of Touch 'N Seal StormBond ® 2
10 Large paddy weight of 60 grams of Touch 'N Seal StormBond ® 2
Table 7: Attachment Resistance Expressed as a Moment - Mf (ft-lbf)
for Mortar Set Systems
Tile
Profile
Tile
Application
Attachment
Resistance
Villa 900 Concrete Tile
Mortar Set11
20.6
11 Bermuda Roof Co. Inc. Tile-Tite Roof Tile Mortar.
5. LABELING
5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as detailed below,
or following statement: "Miami -Dade County Product Control Approved".
LABEL FOR BORAL VILLA 900 CONCRETE TILE
(LOCATED ON THE UNDERSIDE OF TILE)
6. BUILDING PERMIT REQUIREMENTS:
6.1 Application for building permit shall be accompanied by copies of the following:
6.1.1 This Notice of Acceptance.
6.1.2 Any other documents required by Building Official or Applicable building code in order to properly
evaluate the installation of this system.
APPROVED
NOA No.: 21-0712.03
Expiration Date: 09/21/26
Approval Date: 09/16/21
Page 6 of 7
IF
Villa
PROFILE DRAWING
VILLA 900 CONCRETE ROOF TILE
END OF THIS ACCEPTANCE
131
NOA No.: 21-0712.03
Expiration Date: 09/21/26
Approval Date: 09/16/21
Page 7 of 7