Loading...
HomeMy WebLinkAboutNOA Concrete Roof Tile, M IAM I•DADE n MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy Boral Roofing, LLC 7575 Irvine Center Drive, Suite 100 Irvine, CA 92618 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Boral Villa 900 Concrete Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA_number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA# 21-0420.02 and consists of pages 1 through 7. The submitted documentation was reviewed by Alex Tigera. tl 14,1(1A NOA No.: 21-0712.03 Expiration Date: 09/21/26 Approval Date: 09/16/21 Page 1 of 7 0 3 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub Category: Roofing Tiles Material: Concrete 1. SCOPE This renews a system using Boral Villa 900 Concrete Roof Tile, as manufactured Boral Roofing, LLC in Lake Wales, FL and described in Section 2 of this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code, do not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Test Applicant Dimensions Specifications Boral Roofing Villa 900 Length =17" TAS 112 Width = 13" Type 1 b ''V? thick Class III Trim Pieces 1= varies TAS 112 w = varies varying thickness 2.1 PRODUCTS MANUFACTURED BY OTHERS Product Name ICP Adhesives Polyset® AH-160 TILE BONDTM Roof Tile Adhesive "Tile Tite" Roof Tile Mortar Touch `N Seal StormBondo 2 Two - Component Polyurethane Roof Tile Adhesive Product Description Product Description Low profile, interlocking, high pressure extruded concrete roof tile equipped with three nail holes and double rolls. For direct deck, batten, mortar or adhesive set applications. Accessory trim, concrete roof pieces for use at ridges, hips and rakes. Two component polyurethane foam adhesive. Single component polyurethane foam roof tile adhesive. Premixed, pre -bagged roof tile mortar. Two component polyurethane foam adhesive. Touch `N Seal StormBone One One component polyurethane Component Polyurethane Roof Tile foam adhesive. Adhesive 2.2 MANUFACTURING LOCATION 2.2.1. Lake Wales, FL i so �GMAPMPROMVED Manufacturer (With Current NOA) ICP Adhesives and Sealants, Inc. DuPont de Nemours, Inc. Bermuda Roof Co. Inc. DAP Foam, Inc. DAP Foam, Inc. NOA No.: 21-0712.03 Expiration Date: 09/21/26 Approval Date: 09/16/21 Page 2 of 7 0 2.3 EVIDENCE SUBMITTED Test Agency Test Identifier Nutting Engineers 13343.1 Redland Technologies 7161-03 Appendix III 7161-03 Appendix II P0402 The Center for Applied 94-060B Engineering, Inc. .94-084 Redland Technologies The Center for Applied Engineering, Inc. Celotex Corporation Testing Services Walker Engineering, Inc. American Test Lab of South Florida P0631-01 Letter Dated Aug. 1, 1994 Project No. 307025 Test #MDC-76 25-7183-1 25-7183-2 25-7214-2 25-7214-6 528454-2-1 520109-2 Evaluation Calculations Evaluation Calculations Evaluation Calculations Evaluation Calculations Evaluation Calculations Evaluation Calculations Evaluation Calculations RT0617.02-16 RT0503.02-21 Test Name/Reaort TAS 112 Static Uplift Testing TAS 102 & TAS 102(A) Wind Tunnel Testing TAS 108 (Nail -On) Withdrawal Resistance Testing of screw vs. smooth shank nails Static Uplift Testing TAS 101 (Adhesive Set) Static Uplift Testing TAS 101 (Mortar Set) Wind Tunnel Testing TAS 108 (Mortar Set) Wind Tunnel Testing TAS 108.(Nail-On) Wind Driven Rain TAS 100 Static Uplift Testing TAS 102 (2 Quik-Drive Screws, Direct Deck) Static Uplift Testing TAS 102 (1 Quik-Drive Screw, Direct Deck) (1 Quik-Drive Screw, Battens) Static Uplift Testing TAS 101 25-7183 25-7094 25-7496 25-7584 25-7804b-8 25-7804-4 & 5 25-7848-6 Aerodynamic Multipliers Two Patty Adhesive Set System Restoring Moment Due to Gravity TAS 112 TAS 112 Date Apr. 2006 Dec. 1991 Dec. 1991 Sept. 1993 March, 1994 May 1994 July 1994 Aug. 1994 Oct. 1994 Feb. 1995 March, 1995 Sep. 1998 Dec. 1998 March 1995 February 1996 April 1996 December 1996 09/01/16 April 1999 09/01/16 06/29/16 05/12/21 NOA No.: 21-0712.03 Expiration Date: 09/21/26 Approval Date: 09/16/21 Page 3 of 7 a PRI Construction Materials COPO-002-02-11 Static Uplift Testing 10/12/2016 Technologies TAS 101 (Adhesive Set) COPO-002-02-04 Static Uplift Testing 10/12/2016 TAS 101 (Adhesive Set) COPO-002-02-03 Static Uplift Testing 10/12/2016 TAS 101 (Adhesive Set) 2002T003.02 TAS 101 11/06/20 NEMO ETC, LLC 4c-DPBS-20-LSOTM-01.C.R1 TAS 101 12/17/20 3. LIMITATIONS: 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with TAS 106. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 4. INSTALLATION 4.1 Villa 900 Concrete Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119, and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight-W (Ibfl Length -I (ft) Width-w (ft) Villa 900 Concrete Tile 10.90 1.42 1 1.08 Table 2: Aerodynamic Multipliers - X (ft3) Tile Profile X (ft3) Batten Application (ft3) Direct Deck Application Villa 900 Concrete Tile 0.291 0.315 NOA No.: 21-0712.03 Expiration Date: 09/21/26 Approval Date: 09/16/21 Page 4 of 7 Table 3: Restoring Moments due to Gravity - M9 (ft.-Ibf.) Tile Profile 2":12" 3":12" 4":12" 5":12" 6":12" 7":12" or greater Villa 900 Concrete Tile Direct Deck Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck 7.70 7.62 6.56 7.50 6.42 7.34 6.26 7.15 6.08 6.95 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Mechanically Fastened Systems Tile Profile Fastener Type Direct Deck Direct Deck Battens (min 16132" plywood) (min.19/32" plywood) Villa 900 2-10d Ring Shank Nails 27.8 37.4 28.8 Concrete Tile 1-10d Smooth or Screw 8.8 11.8 4.1 Shank Nail 2-10d Smooth or Screw 16.4 21.9 7.1 Shank Nails 1 #8 Screw 25.8 25.8 22.9 2 #8 Screw 47.1 47.1 49.1 1-10d Smooth or Screw 24.3 24.3 24.2 Shank Nail Field Clip) 1-10d Smooth or Screw 19.0 19.0 22.1 Shank Nail Eave Clip) 2-10d Smooth or Screw 35.5 35.5 34.8 Shank Nails Field Clip) 2-10d Smooth or Screw 31.9 31.9 32.2 Shank Nails Eave Clip) Table 5: Attachment Resistance Expressed as a Moment Mf (ft-lbf) for Two Paddy Adhesive' Set Systems Tile Profile Tile Application Minimum Attachment Resistance Villa 900 Concrete Tile TILE BONDTm Roof Tile Adhesive 352 TILE BONDTm Roof Tile Adhesive 673 ICP Adhesives Pol set® AH-160 26.14 Touch 'N Seal StormBond02 555 Touch 'N Seal StormBond® (one component) 725 1 See foam adhesive manufacturer's component approval for installation requirements. 2 Medium paddy weight of 8 grams per paddy of TILE BONDTm Roof Tile Adhesive 3 Medium paddy weight of 16 grams per paddy of TILE BONDTm Roof Tile Adhesive 4 Medium paddy weight of 8 grams per paddy of Polyset® AH-160 5 Medium paddy weight of 8 grams per paddy of Touch 'N Seal StormBond ® 2 6 Medium paddy weight of 8 grams between tile and underlayment, paddy weight of 5 grams on overlap of tile of Touch 'N Seal StormBond ® one component) NOA No.: 21-0712.03 MIAMI•DAD; COUNTY Expiration Date:09/21/26 -0712.03 Approval Date: 09/16/21 Page 5 of 7 Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Single Paddy Adhesive Set Systems Tile Tile Application Minimum Attachment Profile Resistance Villa 900 Concrete Tile ICP Adhesives Polyset@ AH-160 86.67 ICP Adhesives Polyset@) AH-160 45.511 Touch'N Seal StormBond®2 409 Touch 'N Seal StormBond®2 7010 7 Large paddy weight of 54 grams of Polyset@ AH-160 8 Medium paddy weight of 24 grams of Polyset@ AH-160 9 Medium paddy weight of 30 grams of Touch 'N Seal StormBond ® 2 10 Large paddy weight of 60 grams of Touch 'N Seal StormBond ® 2 Table 7: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Mortar Set Systems Tile Profile Tile Application Attachment Resistance Villa 900 Concrete Tile Mortar Set11 20.6 11 Bermuda Roof Co. Inc. Tile-Tite Roof Tile Mortar. 5. LABELING 5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as detailed below, or following statement: "Miami -Dade County Product Control Approved". LABEL FOR BORAL VILLA 900 CONCRETE TILE (LOCATED ON THE UNDERSIDE OF TILE) 6. BUILDING PERMIT REQUIREMENTS: 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by Building Official or Applicable building code in order to properly evaluate the installation of this system. APPROVED NOA No.: 21-0712.03 Expiration Date: 09/21/26 Approval Date: 09/16/21 Page 6 of 7 IF Villa PROFILE DRAWING VILLA 900 CONCRETE ROOF TILE END OF THIS ACCEPTANCE 131 NOA No.: 21-0712.03 Expiration Date: 09/21/26 Approval Date: 09/16/21 Page 7 of 7