Loading...
HomeMy WebLinkAboutNOA Plan Roofing Over Recover DeckMIAMI-DADE MIAMI-DADE COUNTY ° PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 • BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 31525-99 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economv Sika Sarnafil, A Division of Sika Corp. 100 Dan Road Canton, MA 02021 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Sika Sarnafil PVC Single Ply Roofing over Recover Deck. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA" number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 12-0313.18 and consists of pages 1 through 35. The submitted documentation was reviewed by Jorge L. Acebo. NOA No.: 13-0311.05 MIAMI•DADE COUNTY Expiration Date: 05/16/17 ° Approval Date: 07/18/13 Page 1 of 35 ROOFING SYSTEM APPROVAL - Category: Roofing Sub -Category: Single Ply Material: PVC Deck Tyne: Recover Maximum Design Pressure: See Specific Assemblies TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 . Test Product Product Dimensions Specification Description G410 Felt Various ASTM D 4434 Fiberglass reinforced PVC roofing membrane with a non -woven felt backing. G459 Various ASTM D 4434 Fiberglass reinforced PVC Alloy asphalt compatible flashing membrane. Sarnaclad Various Proprietary Heat weldable PVC laminated to galvanized steel flashing product. Sarnaco12121 5 gallons Proprietary Water based bonding adhesive. Sarnaco12170 5 gallons Proprietary Solvent based bonding adhesive. Sarnacol 2163 Proprietary Insulation adhesive. Sarnastack Various Proprietary Prefabricated cone flashing. Sarnatape Various Proprietary Air flow barrier tape. Sarnatred 3.25' x 32.8' Proprietary PVC walkway protection sheet. Sarnavap-10 20' x 100' Proprietary Polyethylene air/vapor barrier. SarnaWalkways Various Proprietary PVC walkway protection sheet. APPROVED INSULATIONS: TABLE 2 Product Manufacturer Product Description (With Current NOA) Sarnatherm Isocyanurate Insulation Sika Sarnafil, A Division of Sika Corp. Sarnatherm 25 PSI Polyisocyanurate insulation board. Sika Sarnafil, A Division of Sika Corp. EPS Type IX Expanded polystyrene with a Generic _ minimum density of 1.8 pcf - XPS Type IV Extruded polystyrene with a Generic minimum density of 1.6 pcf - High Density Wood Wood fiber insulation Generic Fiberboard Perlite Insulation Board Perlite Insulation Generic Type X Gypsum Gypsum Wallboard Generic NOA No.: 13-0311.05 Expiration Date: 05/16/17 Approval Date: 07/18/13 Page 2 of 35 Product Manufacturer Product Description (With Current NOA) DensDeck, DensDeck Prime Silicon treated gypsum Georgia Pacific Gypsum LLC H-Shield Isocyanurate Insulation Hunter Panels, LLC ENRGY 3, JM ISO 3 Isocyanurate Insulation Johns Manville Corp. ENRGY 3 Plus Isocyanurate Insulation with wood Johns Manville Corp. fiberboard facer ENRGY 3 25 PSI Isocyanurate Insulation Johns Manville Corp. ACFoam-II Isocyanurate Insulation Atlas Roofing Corp. ACFoam-III Isocyanurate Insulation Atlas Roofing Corp. ACFoam Composite Isocyanurate Insulation with perlite facer Atlas Roofing Corp. ACFoam Supreme Isocyanurate Insulation Atlas Roofing Corp. Multi-Max-3, Isocyanurate Insulation Rmax Operating, LLC Multi -Max FA-3 Thermaroof Composite-3 Isocyanurate Insulation with perlite facer Rmax Operating, LLC Thermaroof-3 Isocyanurate Insulation Rmax Operating, LLC ISO 95+ GL Isocyanurate Insulation Firestone Building Products Company, LLC APPROVED FASTENERS: TABLE 3 Fastener Product Product Manufacturer Number Name Description Dimensions (With Current NOA) 1. Dekfast 12, 14 & 15 HS Insulation fastener for wood, SFS Intec, Inc. . steel and concrete decks 2. Dekfast Galvalume Steel Galvalume hex stress plate. 2 7/8" x SFS Intec, Inc. Hex 3 1/4" 3. Dekfast Dekflat Round Polypropylene locking plate. 3" x 3 1/4" SFS Intec, Inc. Plastic Lock Plate 4. #12 Standard Roofgrip, Insulation fastener for wood, OMG, Inc. #14 Roofgrip & #15 steel and concrete. Roofgrip Fasteners 5. AccuTrac Hextra Insulation fastener for wood, OMG, Inc. steel and concrete 6. Hextra Plus Pre- Pre -assembled Insulation OMG, Inc. Assembled System fastener and plate 7. OMG 3" Galvalume Galvalume stress plate. 3" round OMG, Inc. Steel Plate 8. AccuTrac Plate Galvalume stress plate. 3" square OMG, Inc. 9. OMG Plastic Plate Polypropylene round plate 3" round OMG, Inc. NOA No.: 13-0311.05 Expiration Date: 05/16/17 Approval Date: 07/18/13 Page 3 of 35 APPROVED FASTENERS: TABLE 3 Fastener Product Product Manufacturer Number Name Description Dimensions (With Current NOA) 10. ASAP RoofGrip Pre- Pre -assembled Insulation Various OMG, Inc. Assembled System fastener and plate 11. OMG G-2 3.5" round galvalume AZ55 3.5" round OMG, Inc. steel plate 12. 3 in. Round Metal Plate 3" round galvalume AZ50 steel 3" round OMG, Inc. plate 13. OMG Super XHD Insulation and membrane Various OMG, Inc. fastener 14. OMG Heavy Duty Insulation and membrane Various OMG, Inc. fastener 15. CD-10 Carbon steel fastener for Various OMG, Inc. concrete decks 16. Sarnafastener Insulation fastener for various Various Sika Sarnafil, A Division of decks Sika Corp. 17. Sarnaplate 3" square galvalume AZ50 steel 3" square Sika Sarnafil, A Division of plate Sika Corp. 18. OMG 2" Barbed Plate Galvalume steel plate 2" round OMG, Inc. 19. Dekfast System ES #12 Pre -assembled Insulation Various SFS Intec, Inc. Plastic fastener and plate 20. Dekfast Isofast IF/IG-C- Galvalume steel plate 1.5" x 3.2" SFS Intec, Inc. 82X40 21. Sarnarail Polymer Batten Polymer batten bar 0.75" x 250' Sika Sarnafil, A Division of Strip Sika Corp. 22. Sarnafastener-XP Membrane and insulation Various Sika Sarnafil, A Division of fastener. Sika Corp. 23. Sarnafil MAXLoad, Membrane and insulation Various Sika Sarnafil, A Division of Sarnafastener MAXLoad fastener. Sika Corp. 24. Sarnadisc XPN Membrane and insulation 1.5" x 3.75" Sika Sarnafil, A Division of fastener. Sika Corp. 25. RhinoBond Insulation Membrane fastening plate Various OMG, Inc. Plate 26. OMG Purlin Membrane and insulation Various OMG, Inc. fastener 27. Sarnabar Galvanized or stainless steel Various Sika Sarnafil, A Division of membrane fastening bar. Sika Corp. 28. Sarnadisc MAXLoad AZ50 galvalume coated steel 3.5" Round Sika Sarnafil, A Division of Plate plate Sika Corp. 29. 3 in. Ribbed Galvalume Round Galvalume plated steel 3" Round OMG, Inc. Plate stress plate 30. #15 Roofgrip Large Carbon Steel Fastener Various OMG, Inc. Head NOA No.: 13-0311.05 Expiration Date: 05/16/17 Approval Date: 07/18/13 Page 4 of 35 ti EVIDENCE SUBMITTED: Test Agency Test Identifier Description Date Celotex Technical Center MTS Job No. 258215 TAS 114 09/09/97 Factory Mutual Research OX3A3.AM FM 4470 07/31/94 Corporation OP6A6.AM FM 4470 03/03/94 2X2A5.AM FM 4470 07/31/94 OB9AO.AM FM 4470 10/22/96 1Z5A6.AM FM 4470 07/18/97 4B3A2.AM FM 4470 06/19/97 1B7A5.AM FM 4470 02/23/98 3001580 FM 4470 11/16/98 3003337 FM 4470 06/11/99 3012964 FM 4470 06/11/02 3015643 FM 4470 12/06/02 3016201 FM 4470 01/28/03 3006785 FM 4470 05/06/04 3017292 FM 4470 09/03/04 3024229 FM 4470 11/16/05 3030053 FM 4470 09/12/07 3028309 FM 4470 03/30/07 3029404 FM 4470 09/09/08 Underwriters Laboratories, Inc. R8992 UL 790 05/15/13 Trinity I ERD S44790.06.13 ASTM D4434 06/05/13 S42480.08.12 Physical Properties 08/20/12 NOA No.: 13-0311.05 MIAMI•DADE COUNTY Expiration Date: 05/16/17 • Approval Date: 07/18/13 Page 5 of 35 APPROVED ASSEMBLIES Membrane Type: PVC Deck Type 7I: Recover, Insulated Deck Description: Concrete/lightweight concrete/cementitious wood fiber/wood/steel System Type A(1): One or more layers of insulation fully adhered with approved asphalt, membrane adhered All General. and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. Vapor Retarder: (Optional) An FM approved vapor retarder approved for use with hot asphalt may be applied to the deck or base insulation layer Fire Barrier: (Optional) Minimum 1/4" Type X Gypsum or DensDeck One or more layers of any of the following insulations: Insulation Layer: Insulation Fasteners Fastener (Table 3) Density/ft2 ACFoam-II, ACFoam-III, ACFoam Composite (bottom layer only), ACFoam Supreme, H-Shield (bottom layer only) any of the above tapered Minimum 1.31' thick N/A N/A ENRGY 3, ENRGY 3 Plus, ENRGY 3 25 PSI Minimum 1.4" thick or tapered N/A N/A DensDeck, DensDeck Prime Minimum'/" thick N/A N/A Multi -Max FA-3, Thermaroof-3 Minimum 1.25" thick or tapered N/A N/A Sarnatherm, Sarnatherm-25 PSI Minimum 1.4" thick or tapered N/A N/A Approved High Density Wood Fiberboard Minimum 1" thick N/A N/A ISO 95+ GL Minimum 1.4" thick or tapered N/A N/A Approved Perlite (base layer only) Minimum %11 thick N/A N/A Note: Existing roof shall be primed with ASTM D 41 asphalt primer and allowed to dry prior to application of insulation. All insulation shall be adhered to the deck in full mopping of approved asphalt within the EVT range and at a rate of 20-401bs/100 ft2 Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels used as a top layer shall be placed with the polyisocyanurate side facing down. NOA No.: 13-0311.05 Expiration Date: 05/16/17 Approval Date: 07/18/13 Page 6 of 35 Membrane: G410 Felt adhered with Sarnacol 2170 applied at 1.25 gal./sq. to the substrate and 0.5 gal./sq. to the back of the Membrane, or Sarnacol 2121 applied to the substrate only at 1.5 to 2.5 gal./sq. Maximum Design Pressure: -45 psf. (See General Limitation #9) NOA No.: 13-0311.05 MIAMI•DADE COUNTY Expiration Date: 05/16/17 "' • • Approval Date: 07/18/13 Page 7 of 35 Membrane Type: PVC Deck Type 7I: Recover, Insulated Deck Description: Min. 2500 psi structural concrete or concrete plank System Type A(2): One or more layers of insulation adhered with approved adhesive, membrane fully adhered All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. One or more layers of the following insulations: Base Insulation Layer: Insulation Fasteners Fastener (Table 3) Density/ft2 ACFoam-II, H-Shield, ENRGY 3, ISO 95+ GL, Sarnatherm Minimum 1" thick N/A N/A DensDeck, DensDeck Prime Minimum 0.25" thick N/A N/A Top Insulation Layer: Insulation Fasteners Fastener (Table 3) Density/ft2 DensDeck, DensDeck Prime Minimum 0.25" thick N/A N/A Note: All insulation shall be adhered to the deck in full coating of OlyBond Adhesive Fastener at a rate of 1 gal/sq. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Membrane: G410 Felt adhered with Sarnaco12121 adhesive applied at 2.25 gal/sq. to the Option #1 insulation using a'/a" x'/a" notched squeegee or Sarnaco12170 adhesive rolled applied as a primer at a rate 1.0-1.25 gal/sq. to the insulation allowed to dry. Following a second coat roller applied of adhesive at 1.0 gal/sq. The roof cover is immediately placed into the adhesive and the top surface rolled with a weighted roller. Maximum Design Pressure, -150 psf. (See General Limitation #9) Option #2 G410 Felt adhered with Sarnacol 2170 adhesive. Adhesive rolled applied as a primer at a rate 1.0-1.25 gal/sq. to the insulation allowed to dry. Following a second coat roller applied of adhesive at 0.5 gal/sq. The roof cover is immediately placed into the adhesive and the top surface rolled with a weighted roller. Maximum Design Pressure; -127.5 psf. (See General Limitation #9) • Maximum Design Pressure: See Membrane Options above. NOA No.: 13-0311.05 Expiration Date: 05/16/17 Approval Date: 07/18/13 Page 8 of 35 Membrane Type: PVC Deck Type 7I: Recover, Insulated Deck Description: Steel / concrete / cementitious wood fiber / lightweight concrete / gypsum / wood System Type A(3): One or more layers of insulation adhered with approved adhesive, membrane fully adhered. All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. Vapor Retarder: (Optional) An FM approved vapor retarder approved for use with hot asphalt may be applied to the deck or base insulation layer Fire Barrier: (Optional) Minimum 1/4" Type X Gypsum or DensDeck One or more layers of any of the following insulations: Base Insulation Layer: Insulation Fasteners Fastener Density/ft2 (Table 3) ACFoam-II, ACFoam-III, ISO 95+ GL, ENRGY 3, Sarnatherm Maximum 1" thick DensDeck, DensDeck Prime Minimum 5/8" thick N/A N/A N/A N/A Note: Insulation shall be adhered to the deck in full coating of OlyBond Adhesive Fastener at a rate of 1 gal/sq. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate Membrane: G410 Felt adhered with Sarnacol 2170 applied at 1.25 gal./sq. to the substrate and 0.5 gal./sq. to the back of the membrane, or Sarnacol 2121 applied to the substrate only at 1.5 to 2.5 gal./sq. Maximum Design Pressures: -45 psf. (See General Limitation #9) NOA No.: 13-0311.05 MIAMI•DADE COUNTY Expiration Date: 05/16/17 a .. i Approval Date: 07/18/13 .Page 9 of 35 Membrane Type: PVC Deck Type 7I: Recover, Insulated Deck Description: Min. 2500 psi structural concrete or concrete plank System Type A(4): One or more layers of insulation adhered with approved adhesive, membrane fully adhered All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. One or more layers of the following insulations: Base Insulation Layer (Optional): Insulation Fasteners Fastener (Table 3) Density/ft2 Approved EPS Minimum 2" thick N/A N/A Top Insulation Layer: Insulation Fasteners Fastener (Table 3) Density/ft2 Approved High Density Wood Fiberboard Minimum 1" thick N/A N/A DensDeck, DensDeck Prime Minimum 0.25" thick N/A N/A Note: All insulation shall be adhered to the deck in 3/" —1" wide beads 12" o.c. of OlyBond 500 or Spot Shot Adhesive Fastener. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Membrane: G410 Felt adhered with Sarnacol 2121 adhesive applied at 2.25 gal/sq. to the insulation using a'/" x'/4" notched squeegee. Or Maximum Design Pressure: G410 Felt adhered with Sarnacol 2170 adhesive. Adhesive rolled applied as a primer at a rate 1.0-1.25 gal/sq. to the insulation allowed to dry. Following a second coat roller applied of adhesive at 0.5 gal/sq. The roof cover is immediately placed into the adhesive and the top surface rolled with a weighted roller. -120 psf. (See General Limitation #9) NOA No.: 13-0311.05 Expiration Date: 05/16/17 Approval Date: 07/18/13 Page 10 of 35 Membrane Type: PVC Deck Type 7I: Recover, Insulated Deck Description: Cementitious wood fiber / Gypsum System Type A(5): One or more layers of insulation adhered with approved adhesive, membrane fully adhered. All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. Base Insulation Layer: Insulation Fasteners Fastener (Table 3) - Density/ft2 ACFoam-II, H-Shield, ENRGY 3, Sarnatherm Minimum 1" thick N/A N/A DensDeck, DensDeck Prime Minimum 0.25" thick N/A N/A Top Insulation Layer: Insulation Fasteners Fastener Density/ft2 DensDeck, DensDeck Prime Minimum 0.25" thick N/A N/A Note: All insulation shall be adhered to the deck in full coating of OlyBond Adhesive Fastener at a rate of 1 gal/sq. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Membrane: G410 Felt adhered with Sarnacol 2170 applied at 1.25 gal./sq. to the substrate and 0.5 gal./sq. to the back of the Membrane, or Sarnacol 2121 applied to the substrate only at 1.5 to 2.5 gal./sq. Maximum Design Pressure: MIAMI•DADE COUNTY • -45 psf. (See General Limitation #9) NOA No.: 13-0311.05 Expiration Date: 05/16/17 Approval Date: 07/18/13 Page 11 of 35 Membrane Type: PVC Deck Type 7I: Recover, Insulated Deck Description: Min. 2500 psi structural concrete or concrete plank System Type A(6): One or more layers of insulation adhered with approved adhesive, membrane fully adhered All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. One or more layers of the following insulations: Base Insulation Layer (Optional): Insulation Fasteners Fastener (Table 3) Density/ft2 ACFoam-II, H-Shield, Sarnatherm Minimum 1.5" thick N/A N/A Top Insulation Layer: Insulation Fasteners Fastener (Table 3) Density/ft2 DensDeck, DensDeck Prime Minimum 0.25" thick N/A N/A Note: All insulation shall be adhered to the deck in V —1" wide beads 12" o.c. of OlyBond 500 or Spot Shot Adhesive Fastener. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Membrane: G410 Felt adhered with Sarnacol 2121 adhesive applied at 2.25 gal/sq. to the insulation using a'/a" x'/4" notched squeegee or Sarnacol 2170 adhesive rolled applied as a primer at a rate 1.0-1.25 gal/sq. to the insulation allowed to dry. Following a second coat roller applied of adhesive at 1.0 gal/sq. The roof cover is immediately placed into the adhesive and the top surface rolled with a weighted roller. Or Maximum Design Pressure: MIAMI-DADE COUNTY LIUMIMI G41-0 Felt adhered with Sarnacol 2170 adhesive. Adhesive rolled applied as a primer at a rate 1.0-1.25 gal/sq. to the insulation allowed to dry. Following a second coat roller applied of adhesive at 0.5 gal/sq. The roof cover is immediately placed into the adhesive and the top surface rolled with a weighted roller. -120 psf. (See General Limitation #9) NOA No.: 13-0311.05 Expiration Date: 05/16/17 Approval Date: 07/18/13 Page 12 of 35 Membrane Type: PVC Deck Type 7I:. Recover, Insulated Deck Description: Min. 2500 psi structural concrete or concrete plank System Type A(7): One or more layers of insulation adhered with approved adhesive, membrane fully adhered All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. One or more layers of the following insulations: Base Insulation Layer: Insulation Fasteners Fastener (Table 3) Density/ft2 ENRGY 3, Sarnatherm, H-Shield Minimum 1.5" thick N/A N/A Top Insulation Layer: Insulation Fasteners Fastener (Table 3) Density/ft2 DensDeck, DensDeck Prime Minimum 0.25" thick N/A N/A Note: All insulation shall be adhered to the deck in %'1 — 1" wide beads 12" o.c. of OlyBond 500 or Spot Shot Adhesive Fastener. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Membrane: G410 Felt adhered with Sarnacol 2121 adhesive applied at 2.25 gal/sq. to the insulation using a'/4" x'/4" notched squeegee or Sarnacol 2170 adhesive rolled applied as a primer at a rate 1.0-1.25 gal/sq. to the insulation allowed to dry. Following a second coat roller applied of adhesive at 1.0 gal/sq. The roof cover is immediately placed into the adhesive and the top surface rolled with a weighted roller. Or G410 Felt adhered with Sarnacol 2170 adhesive. Adhesive rolled applied as a primer at a rate 1.0-1.25 gal/sq. to the insulation allowed to dry. Following a _ second coat roller applied of adhesive at 0.5 gal/sq. The roof cover is immediately placed into the adhesive and the top surface rolled with a weighted roller. Maximum Design Pressure: -120 psf. (See General Limitation #9) NOA No.: 13-0311.05 Expiration Date: 05/16/17 Approval Date: 07/18/13 Page 13 of 35 Membrane Type: PVC Deck Type 7I: Recover, Insulated Deck Description: Min. 2500 psi structural concrete or concrete plank System Type A(8): One or more layers of insulation adhered with approved adhesive, membrane fully adhered All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. One or more layers of the following insulations: Base Insulation Layer: Insulation Fasteners Fastener (Table 3) Density/ft2 ISO 95+ GL, H-Shield Minimum 1.5" thick N/A N/A Top Insulation Layer: Insulation Fasteners Fastener (Table 3) Density/ft2 Approved High Density Wood Fiberboard Minimum 1" thick N/A N/A Note: All insulation shall be adhered to the deck in %11-1" wide beads 12" o.c. of OlyBond 500 or Spot Shot Adhesive Fastener. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Membrane: G410 Felt adhered with Sarnacol 2121 adhesive applied at 2.25 gal/sq. to the insulation using all/4" x'/a" notched squeegee. Maximum Design Pressure: -120 psf. (See General Limitation #9) NOA No.: 13-0311.05 MIAMI•DADE COUNTY Expiration Date: 05/16/17 ' ' ' Approval Date: 07/18/13 Page 14 of 35 Membrane Type: PVC Deck Type 7I: Recover, Insulated Deck Description: Min. 2500 psi structural concrete or concrete plank System Type A(9): One or more layers of insulation adhered with approved adhesive, membrane fully adhered , All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. One or more layers of the following insulations: Base Insulation Layer: Insulation Fasteners Fastener (Table 3) Density/ft2 Approved XPS Minimum V thick N/A N/A Top Insulation Layer: Insulation Fasteners Fastener (Table 3) Density/ft2 DensDeck, DensDeck Prime Minimum 0.25" thick N/A N/A Note: All insulation shall be adhered to the deck in %'1-1" wide beads 12" o.c. of OlyBond 500 or Spot Shot Adhesive Fastener. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Membrane: G410 Felt adhered with Sarnaco12121 adhesive applied at 2.25 gal/sq. to the insulation using a'/4" x'/4" notched squeegee or Sarnaco12170 adhesive rolled applied as a primer at a rate 1.0-1.25 gal/sq. to the insulation allowed to dry. Following a second coat roller applied of adhesive at 1.0 gal/sq. The roof cover is immediately placed into the adhesive and the top surface rolled with a weighted roller. Or G410 Felt adhered with Sarnaco12170 adhesive. Adhesive rolled applied as a primer at a rate 1.0-1.25 gal/sq. to the insulation allowed to dry. Following a second coat roller applied of adhesive at 0.5 gal/sq. The roof cover is immediately placed into the adhesive and the top surface rolled with a weighted roller. Maximum Design Pressure: -120 psf. (See General Limitation #9) NOA No.: 13-0311.05 Expiration Date: 05/16/17 Approval Date: 07/18/13 Page 15 of 35 Membrane Type: PVC Deck Type 7I: Recover, Insulated Deck Description: Min. 200 psi lightweight insulating concrete System Type A(10): One or more layers of insulation adhered with approved adhesive, membrane fully adhered + All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. One or more layers of the following insulations: Base Insulation Layer: Insulation Fasteners Fastener (Table 3) Density/ft2 ACFoam-H, H-Shield, Sarnatherm Minimum 1.5" thick N/A N/A Approved High Density Wood Fiberboard Minimum 0.5" thick N/A N/A DensDeck, DensDeck Prime Minimum 0.25" thick N/A N/A Top Insulation Layer: Insulation Fasteners Fastener (Table 3) Density/ft2 Approved High Density Wood Fiberboard Minimum 1" thick N/A N/A DensDeck, DensDeck Prime Minimum 0.25" thick N/A N/A Note: All insulation shall be adhered to the deck in %1' —1" wide beads 12" o.c. of OlyBond 500 or Spot Shot Adhesive Fastener. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Membrane: G410 Felt adhered with Sarnacol 2121 adhesive applied at 2.25 gal/sq. to the insulation using a'/4" x'/4" notched squeegee. Or Sarnaco12170 adhesive rolled applied as a primer at a rate 1.0-1.25 gal/sq. to the insulation allowed to dry. Following a second coat roller applied of adhesive at 1.0 gal/sq. The roof cover is immediately placed into the adhesive and the top surface rolled with a weighted roller. Maximum Design Pressure: -120 psf. (See General Limitation #9) NOA No.: 13-0311.05 MIAMI•DADE COUNTY Expiration Date: 05/16/17 Approval Date: 07/18/13 Page 16 of 35 Membrane Type: PVC Deck Type 7I: Recover, Insulated Deck Description: Lightweight insulating concrete System Type A(11): One or more layers of insulation adhered with approved adhesive, membrane fully adhered All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. One or more layers of the following insulations: Insulation Layer: Insulation Fasteners Fastener (Table 3) Density/ft2 ACFoam-II, H-Shield, ENRGY 3, Sarnatherm Minimum 1" thick or tapered N/A N/A Note: All insulation shall be adhered to the deck in V —1" wide beads 12" o.c. of OlyBond 500 or Spot Shot Adhesive Fastener. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Membrane: G410 Felt adhered with Sarnacol 2121 adhesive applied at 2.25 gal/sq. to the insulation using a'/4" x'/a" notched squeegee. Or G410 Felt adhered with Sarnacol 2170 adhesive. Adhesive rolled applied as a primer at a rate 1.0-1.25 gal/sq. to the insulation allowed to dry. Following a second coat roller applied of adhesive at 0.5 gal/sq. The roof cover is immediately placed into the adhesive and the top surface rolled with a weighted roller. Maximum Design Pressure: -90 psf. (See General Limitation #9) NOA No.: 13-0311.05 Expiration Date: 05/16/17 Approval Date: 07/18/13 Page 17 of 35 Membrane Type: PVC Deck Type 7I: Recover, Insulated Deck Description: Gypsum System Type A(12): One or more layers of insulation adhered with approved adhesive, membrane fully adhered All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. One or more layers of the following insulations: Insulation Layer: Insulation Fasteners Fastener (Table 3) Density/ft2 ACFoam-II, H-Shield, ENRGY 3, Sarnatherm Minimum 1.5" thick N/A N/A Note: All insulation shall be adhered to the deck in '/" —1" wide beads 12" o.c. of OlyBond 500 or Spot Shot Adhesive Fastener. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Membrane: G410 Felt adhered with Sarnacol 2170 adhesive. Adhesive rolled applied as a primer at a rate 1.0-1.25 gal/sq. to the insulation allowed to dry. Following a second coat roller applied of adhesive at 0.5 gal/sq. The roof cover is immediately placed into the adhesive and the top surface rolled with a weighted roller. Or G410 Felt adhered with Sarnacol 2121 adhesive applied at 2.25 gal/sq. to the insulation using a'/" x'/4" notched squeegee. Maximum Design Pressure: -112.5 psf. (See General Limitation #9) NOA No.: 13-0311.05 Expiration Date: 05/16/17 Approval Date: 07/18/13 Page 18 of 35 Membrane Type: PVC Deck Type 7I: Recover, Insulated Deck Description: Gypsum System Type A(13): One or more layers of insulation adhered with approved adhesive, membrane fully adhered All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. One or more layers of the following insulations: Insulation Layer: Insulation Fasteners Fastener (Table 3) Density/ft2 Approved High Density Wood Fiberboard Minimum 0.5" thick N/A N/A Note: All insulation shall be adhered to the deck in %1' —1" wide beads 12" o.c. of OlyBond 500 or Spot Shot Adhesive Fastener. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Membrane: G410 Felt adhered with Sarnacol 2121 adhesive applied at 2.25 gal/sq. to the insulation using a''/a" x'/" notched squeegee. Maximum Design Pressure: -135 psf. (See General Limitation #9) NOA No.: 13-0311.05 Expiration Date: 05/16/17 Approval Date: 07/18/13 Page 19 of 35 Membrane Type: PVC Deck Type 7I: Recover, Insulated Deck Description: Gypsum System Type A(14): One or more layers of insulation adhered with approved adhesive, membrane fully adhered All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. Vapor Retarders: (Optional) Any UL or FM approved asphaltic vapor retarder may be installed over the deck or the base layer of insulation One or more layers of the following insulations: Base Insulation Layer (Optional): Insulation Fasteners Fastener (Table 3) Density/ft2 ACFoam-II, ACFoam-III, H-Shield, ISO 95+ GL, ENRGY 3, Multi-Max-3, Sarnatherm Minimum 1.5" thick or tapered N/A N/A Top Insulation Layer: Insulation Fasteners Fastener (Table 3) Density/ft2 DensDeck, DensDeck Prime Minimum 0.25" thick N/A N/A Approved High Density Wood Fiberboard Minimum 0.5" thick N/A N/A Note: All insulation shall be adhered to the deck in '/2" to %11 wide beads 12" o.c. of Millennium One Step Foamable Adhesive or Sarnacol 2163. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Membrane: G410 Felt adhered with Sarnacol 2121 adhesive applied at 2.25 gal/sq. to the insulation using a''/4" x'/4" notched squeegee or Sarnacol 2170 adhesive rolled applied as a primer at a rate 1.0-1.25 gal/sq. to the insulation allowed to dry. Following a second coat roller applied of adhesive at 1.0 gal/sq. The roof cover is immediately placed into the adhesive and the top surface rolled with a weighted roller. Or G410 Felt adhered with Sarnacol 2121 adhesive applied at 2.25 gal/sq. to the insulation using a'/4" x'/4" notched squeegee. • Maximum Design Pressure: -45 psf. (See General Limitation #9) NOA No.: 13-0311.05 Expiration Date: � 05/16/17 Approval Date: 07/18/13 Page 20 of 35 Membrane Type: PVC Deck Type 7I: Recover, Insulated Deck Description: Min. 2500 psi structural concrete or concrete plank System Type A(15): One or more layers of insulation adhered with approved adhesive, membrane fully adhered All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code requirements and are field fabricated utilizing the approved membranes - listed in Table 1. Vapor Retarders: (Optional) Any UL or FM approved asphaltic vapor retarder may be installed over the deck or the base layer of insulation One or more layers of the following insulations: Insulation Layer: Insulation Fasteners Fastener (Table 3) Density/ft2 ACFoam-II, Multi-Max-3, ENRGY 3, H-Shield, Sarnatherm Minimum 1.5" thick N/A N/A DensDeck, DensDeck Prime Minimum 0.25" thick N/A N/A Note: All insulation shall be adhered to the deck in '/" to %" wide beads 12" o.c. of Millennium One Step Foamable Adhesive or Sarnaco12163. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Membrane: G410 Felt adhered with Sarnacol 2121 adhesive applied at 2.25 gal/sq. to the Option #1 insulation using a'/4" x'/4" notched squeegee or Sarnacol 2170 adhesive rolled applied as a primer at a rate 1.0-1.25 gal/sq. to the insulation allowed to dry. Following a second coat roller applied of adhesive at 1.0 gal/sq. The roof cover is immediately placed into the adhesive and the top surface rolled with a weighted roller. Maximum Design Pressure; -157.5 psf. (See General Limitation #9 Option #2 G410 Felt adhered with Sarnacol 2170 adhesive. Adhesive rolled applied as a primer at a rate 1.0-1.25 gal/sq. to the insulation allowed to dry. Following a second coat roller applied of adhesive at 0.5 gal/sq. The roof cover is immediately placed into the adhesive and the top surface rolled with a weighted roller. Maximum Design Pressure, -127.5 psf. (See General Limitation #9) Maximum Design Pressure: See membrane options above. NOA No.: 13-0311.05 Expiration Date: 05/16/17 Approval Date: 07/18/13 Page 21 of 35 Membrane Type: PVC Deck Type 7I: Recover, Insulated • Deck Description: Min. 2500 psi structural concrete or concrete plank System Type A(16): One or more layers of insulation adhered with approved adhesive, membrane fully adhered All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. Vapor Retarders: (Optional) Any UL or FM approved asphaltic vapor retarder may be installed over the deck or the base layer of insulation One or more layers of the following insulations: Base Insulation Layer: Insulation Fasteners Fastener (Table 3) Density/fe ACFoam-II, Multi-Max-3, ENRGY 3, H-Shield, ISO 95+ GL, Sarnatherm Minimum 1.5" thick N/A N/A Top Insulation Layer: Insulation Fasteners Fastener (Table 3) Density/fe Approved High Density Wood Fiberboard Minimum 0.5" thick N/A N/A Note: All insulation shall be adhered to the deck in 1/" to %" wide beads 12" o.c. of Millennium One Step Foamable Adhesive Sarnacol 2163 or Millennium Pourable Foam Insulation Adhesive. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Membrane: G410 Felt adhered with Sarnacol 2121 adhesive applied at 2.25 gal/sq. to the insulation using a'/4" x'/4" notched squeegee. .Maximum Design , ' Pressure: -127.5 psf. (See General Limitation #9) NOA No.: 13-0311.05 MIAMI•DADECOUNTY Expiration Date: 05/16/17 �Lll'"Yjqlj Approval Date: 07/18/13 Page 22 of 35 Membrane Type: PVC Deck Type 7I: Recover, Insulated Deck Description: Min. 2500 psi structural concrete or concrete plank System Type A(17): One or more layers of insulation adhered with approved adhesive, membrane fully adhered All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. Vapor Retarders: (Optional) Any UL or FM approved asphaltic vapor retarder may be installed over the deck or the base layer of insulation One or more layers of the following insulations: Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 Approved XPS Insulation Boards Minimum 1" thick N/A N/A Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 DensDeck, DensDeck Prime Minimum 0.25" thick N/A N/A Note: All insulation shall be adhered to the deck in I/" to '/" wide beads 12" o.c. of Millennium Pourable Foam Insulation Adhesive. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Membrane: G410 Felt adhered with Sarnacol 2121 adhesive applied at 2.25 gal/sq. to the insulation using a'/" x'/a" notched squeegee or Sarnacol 2170 adhesive rolled applied as a primer at a rate 1.0-1.25 gal/sq. to the insulation allowed to dry. Following a second coat roller applied of adhesive at 1.0 gal/sq. The roof cover is immediately placed into the adhesive and the top surface rolled with a weighted roller. Maximum Design Pressure: -202.5 psf. (See General Limitation #9) NOA No.: 13-0311.05 MIAMI•DADE COUNTY Expiration Date: 05/16/17 "' • • Approval Date: 07/18/13 Page 23 of 35 Membrane Type: PVC Deck Type 7I: Recover, Insulated • Deck Description: Min. 2500 psi structural concrete or concrete plank System Type A(18): One or more layers of insulation adhered with approved adhesive, membrane fully adhered All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. Vapor Retarders: (Optional) Any UL or FM approved asphaltic vapor retarder may be installed over the deck or the base layer of insulation One or more layers of the following insulations: Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 Approved XPS or EPS Minimum 1" thick N/A N/A Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 Approved High Density Wood Fiberboard Minimum 0.5" thick N/A N/A Note: All insulation shall be adhered to the deck in lh" to '/" wide beads 12" o.c. of Millennium Pourable Foam Insulation Adhesive. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Membrane: G410 Felt adhered with Sarnacol 2121 adhesive applied at 2.25 gal/sq. to the insulation using a'/4" x'/" notched squeegee. Maximum Design -150 psf. (with EPS) (See General Limitation #9) Pressure: -162.5 psf. (with XPS) (See General Limitation #9) NOA No.: 13-0311.05 Expiration Date: 05/16/17 Approval Date: 07/18/13 Page 24 of 35 Membrane Type: PVC Deck Type 7I: Recover, Insulated Deck Description: Min. 2500 psi structural concrete or concrete plank System Type A(19): One or more layers of insulation adhered with approved adhesive, membrane fully adhered All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. Vapor Retarders: (Optional) Any UL or FM approved asphaltic vapor retarder may be installed over the deck or the base layer of insulation One or more layers of the following insulations: Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft, ACFoam II, ACFoam III, ENRGY 3, Sarnatherm, H-Shield Minimum 1.5" thick N/A N/A Top Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 Approved High Density Wood Fiberboard Minimum 0.25" thick N/A N/A Note: All insulation shall be adhered to the deck in V211 to %" wide beads 12" o.c, of Millennium Pourable Foam Insulation Adhesive. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Membrane: G410 Felt adhered with Sarnacol 2121 adhesive applied at 2.25 gal/sq. to the insulation using a'/" x'/4" notched squeegee. Maximum Design Pressure: MIAMI•DADE COUNTY F-11...• 1411 -127.5 psf. (See General Limitation #9) NOA No.: 13-0311.05 Expiration Date: 05/16/17 Approval Date: 07/18/13 Page 25 of 35 Membrane Type: PVC Deck Type 7I: Recover, Insulated Deck Description: Min. 2500 psi structural concrete or concrete plank System Type A(20): One or more layers of insulation adhered with approved adhesive, membrane fully adhered All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. Vapor Retarders: (Optional) Any UL or FM approved vapor retarder may be installed over the deck. One or more layers of any of the following insulations: Insulation Layer: Insulation Fasteners Fastener (Table 3) Density/ft2 ACFoam-II, ACFoam-III, Multi -Max FA-3, JM ISO 3, ISO 95+GL, Sarnatherm Minimum 1.5" thick N/A N/A DensDeck, DensDeck Prime Minimum 0.5" thick N/A N/A Note: All insulation shall be adhered to the deck in 3-3.5" wide beads spaced 12" o.c. of TITE- SET Roofing Adhesive or 3M Polyurethane Foam Insulation Adhesive CR-20. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Membrane: G410 Felt adhered with Sarnacol 2121 adhesive applied at 2.25 gal/sq. to the insulation using a''/4" x'/4" notched squeegee or with Sarnacol 2170 adhesive rolled applied as a primer at a rate 1.0-1.25 gaUsq. to the insulation allowed to dry. Following a second coat roller applied of adhesive at 1.0 gal/sq. The roof cover is immediately placed into the adhesive and the top surface rolled with a weighted roller. Maximum Design Pressure: -202.5 psf. (See General Limitation #9) NOA No.: 13-0311.05 Expiration Date: 05/16/17 Approval Date: 07/18/13 Page 26 of 35 Membrane Type: PVC Deck Type 7I: Recover, Insulated Deck Description: Min. 2500 psi structural concrete or concrete plank System Type A(21): One or more layers of insulation adhered with approved adhesive, membrane fully adhered All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. Vapor Retarders: (Optional) Any UL or FM approved vapor retarder may be installed over the deck. One or more layers of any of the following insulations: Base Insulation Layer (Optional): Insulation Fasteners Fastener (Table 3) Density/W ACFoam-II, ACFoam-III, Multi -Max FA-3, JM ISO 3, ISO 95+GL, Sarnatherm, H-Shield Minimum 1.5" thick N/A N/A DensDeck, DensDeck Prime Minimum 0.5" thick N/A N/A Top Insulation Layer: Insulation Fasteners Fastener (Table 3) Density/ft2 ACFoam-II, ACFoam-III, Multi -Max FA-3, Sarnatherm Tapered N/A N/A Note: All insulation shall be adhered to the deck in 3-3.5" wide beads spaced 12" o.c. of TITE- SET Roofing Adhesive or 3M Polyurethane Foam Insulation Adhesive CR-20. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Membrane: G410 Felt adhered with Sarnacol 2121 adhesive applied at 2.25 gal/sq. to the insulation using a''/4" x'/4" notched squeegee or with Sarnaco12170 adhesive rolled applied as a primer at a rate 1.0-1.25 gal/sq. to the insulation allowed to dry. Following a second coat roller applied of adhesive at 1.0 gal/sq. The roof cover is immediately placed into the adhesive and the top surface rolled with a weighted roller. Maximum Design Pressure: -45 psf. (See General Limitation #9) NOA No.: 13-0311.05 Expiration Date: 05/16/17 Approval Date: 07/18/13 Page 27 of 35 Membrane Type: PVC Deck Type 7I: Recover, Insulated Deck Description: Min. 2500 psi structural concrete or concrete plank System Type A(22): One or more layers of insulation adhered with approved adhesive, membrane fully adhered All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. Vapor Retarders: (Optional) Any UL or FM approved vapor retarder may be installed over the deck. One or more layers of any of the following insulations: Insulation Layer: Insulation Fasteners Fastener (Table 3) Density/fe DensDeck, DensDeck Prime Minimum 0.5" thick N/A N/A Note: All insulation shall be adhered to the deck in 3-3.5" wide beads spaced 12" o.c. of TITE- SET Roofing Adhesive or 3M Polyurethane Foam Insulation Adhesive CR-20. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Membrane: G410 Felt adhered with Sarnacol 2121 adhesive applied at 2.25 gal/sq. to the insulation using a'/4" x'/4" notched squeegee or with Sarnaco12170 adhesive rolled applied as a primer at a rate 1.0-1.25 gal/sq. to the insulation allowed to dry. Following a second coat roller applied of adhesive at 1.0 gal/sq. The roof cover is immediately placed into the adhesive and the top surface rolled with a weighted roller. Maximum Design Pressure: -202.5 psf. (See General Limitation #9) NOA No.: 13-0311.05 Expiration Date: 05/16/17 Approval Date: 07/18/13 Page 28 of 35 Membrane Type: PVC Deck Type 7I: Recover, Insulated - Deck Description: Concrete/lightweight concrete/cementitious wood fiber/wood/steel System Type B: Base layer of insulation mechanically attached, optional top layer fully adhered with approved asphalt, membrane adhered. ' All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. Vapor Retarder: (Optional) An FM approved vapor retarder approved for use with hot asphalt may be applied to the deck or base insulation layer Fire Barrier: (Optional) Minimum 1/4" Type X Gypsum or DensDeck. Base Insulation Layer: Insulation Fasteners Fastener (Table 3) Density/fe ACFoam II, ACFoam Composite, H-Shield Minimum 1.3" thick or tapered Any approved fastener 1:2 ft2 Minimum 2" thick or tapered listed in Table 3 1:4 ft2 ENRGY-3, ENRGY 3 Plus, ENRGY 3 25 PSI Minimum 1.4" thick or tapered Any approved fastener 1:2 ft2 Minimum 2" thick or tapered listed in Table 3 1:4 ft2 DensDeck, DensDeck Prime Minimum'/a" thick _ Any approved fastener 1:1.2 ft2 Minimum'/z" thick listed in Table 3 1:1.7 ft2 Multi -Max FA-3, Thermaroof Composite-3 Minimum 1.25" thick or tapered Any approved fastener 1:2 ft2 Minimum 2" thick or tapered listed in Table 3 1:4 ft2 Sarnatherm, Sarnatherm-25 PSI Minimum 1.4" thick Any approved fastener 1:2 ft2 Minimum 2" thick listed in Table 3 1:4 ft2 ISO 95+ GL Minimum 1.4" thick or tapered Any approved fastener 1:2 ft2 Minimum 2" thick or tapered listed in Table 3 1:4 ft2 - Approved High Density Wood Fiberboard Minimum 1" thick Any approved fastener 1:2 ft2 - listed in Table 3 Approved Perlite - Minimum %11 thick Any approved fastener 1:2 ft2 listed in Table 3 NOA No.: 13-0311.05 Expiration Date: 05/16/17 Approval Date: 07/18/13 Page 29 of 35 Note: Base layers of insulation shall be mechanically attached using the fastener density listed. The insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Insulation fasteners shall be tested for withdrawal resistance in compliance with Protocol TAS 105 to confirm compliance with the wind load requirements. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Top Insulation Layer (Optional): Insulation Fasteners Fastener (Table 3) Density/ft2 ACFoam-II Minimum 1.3" thick or tapered N/A N/A ENRGY 3, ENRGY 3 Plus, ENRGY 3 25 PSI Minimum 1.4" thick or tapered - N/A N/A DensDeck, DensDeck Prime Minimum'/4" thick N/A N/A Multi -Max FA-3 Minimum 1.25" thick or tapered N/A N/A Sarnatherm, Sarnatherm-25 PSI Minimum 1.4" thick N/A N/A ISO 95+ GL Minimum 1.4" thick or tapered N/A N/A Approved High Density Wood Fiberboard Minimum 1" thick N/A N/A Note: Optional top layer of insulation shall be adhered with approved asphalt within the EVT range and at a rate of 20-40 lbs./100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Composite insulation boards used as a top layer shall be installed with the polyisocyanurate face down. Membrane: G410 Felt adhered with Sarnacol 2170 applied at 1.25 gal./sq. to the substrate and .5 gal./sq. to the back of the Membrane, or Sarnacol 2121 applied to the substrate only at 1.5 to 2.5 gal./sq. Maximum Design Pressure: -45 psf. (See General Limitation 99) NOA No.: 13-0311.05 Expiration Date: 05/16/17 Approval Date: 07/18/13 Page 30 of 35 Membrane Type: PVC Deck Type 7I: Recover, Insulated Deck Description: Concrete/lightweight concrete/cementitious wood fiber/wood/steel System Type C(1): All layers of insulation simultaneously attached, membrane adhered. All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are • not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. Vapor Retarder: (Optional) Sarnavap-10 vapor barrier applied directly to the deck or over base insulation layer. Fire Barrier: (Optional) Minimum 1/4" Type X Gypsum or DensDeck. Base Insulation Layer: Insulation Fasteners Fastener (Table 3) Density/ft2 ACFoam-II, ACFoam-III, ACFoam Composite, ACFoam Supreme, H-Shield Minimum 1.3" thick or tapered N/A N/A ENRGY 3, ENRGY 3 Plus, ENRGY 3 25 PSI Minimum 1.4" thick or tapered N/A N/A DensDeck, DensDeck Prime Minimum'/" thick N/A N/A Multi -Max FA-3, Thermaroof-3 Minimum 1.25" thick or tapered N/A N/A Sarnatherm, Sarnatherm-25 PSI Minimum 1.4" thick or tapered N/A N/A Approved High Density Wood Fiberboard Minimum 1" thick N/A N/A ISO 95+ GL Minimum 1.4" thick or tapered N/A N/A Approved Perlite Minimum %11 thick N/A N/A Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density. Insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. NOA No.: 13-0311.05 Expiration Date: 05/16/17 Approval Date: 07/18/13 Page 31 of 35 Top Insulation Layer: Insulation Fasteners Fastener (Table 3) Density/ft2 ACFoam-II, ACFoam-III • Minimum 1.3" thick or tapered Any approved fastener 1:2 ft2 Minimum 2" thick or tapered listed in Table 3 1:4 ft2 ENRGY 3, ENRGY 3 Plus, ENRGY 3 25 PSI Minimum 1.4" thick or tapered Any approved fastener 1:2 ft2 Minimum 2" thick or tapered listed in Table 3 1:4 ft2 DensDeck, DensDeck Prime Minimum'/4" thick Any approved fastener 1:1.2 ft2 Minimum V2" thick listed in Table 3 1:1.7 ft2 Sarnatherm, Sarnatherm 25 PSI Minimum 1.4" thick Any approved fastener 1:2 ft2 Minimum 2" thick listed in Table 3 1:4 ft2 ISO 95+ GL Minimum 1.4" thick or tapered Any approved fastener 1:2 ft2 Minimum 2" thick or tapered listed in Table 3 1:4 ft2 Approved High Density Wood Fiberboard Minimum 1" thick Any approved fastener 1:2 ft2 listed in Table 3 Note: All layers of insulation shall be mechanically attached using the fastener density listed above. The insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Insulation fasteners shall be tested for withdrawal resistance in compliance with Testing Application Standard TAS 105 to confirm compliance with the wind load requirements. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Membrane: G410 Felt adhered with Sarnacol 2170 applied at 1.25 gal./sq. to the substrate and 0.5 gal./sq. to the back of the Membrane, or Samacol 2121 applied to the substrate only at 1.5 to 2.5 gal./sq. Maximum Design Pressure: -45 psf. (See General Limitation #9) NOA No.: 13-0311.05 Expiration Date: 05/16/17 Approval Date: 07/18/13 Page 32 of 35 Membrane Type: PVC Deck Type 7I: Recover, Insulated Deck Description: Minimum 2500 psi concrete or concrete plank or min. 18-22 ga. steel System Type C(2): All layers of insulation simultaneously fastened; membrane fully adhered. All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. Base Insulation Layer: Insulation Fasteners Fastener (Table 3) Density/ft2 Any Approved Polyisocyanurate Listed in Table 2 Minimum 1.51' thick N/A N/A Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density. Insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Top Insulation Layer: Insulation Fasteners Fastener (Table 3) Density/ft2 DensDeck Prime Minimum 5/8" thick 16 and 17 1:2 Note: Insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Membrane: G410 Felt adhered with Sarnaco12121 adhesive applied at a rate of 2.0 — 2.5 gal/sq. to substrate. Minimum 3" wide side lap is sealed with a 1.5" wide heat weld. Maximum Design Pressures: -52.5 psf. (See General Limitation #7) NOA No.: 13-0311.05 Expiration Date: 05/16/17 Approval Date: 07/18/13 Page 33 of 35 Membrane Type: PVC Deck Type 7: Recover, Non -Insulated Deck Description: Concrete/lightweight concrete/cementitious wood fiber/steel System Type F: Membrane adhered to sustrate. All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. Fire Barrier: None Membrane: G410 Felt adhered with Sarnacol 2170 applied to the substrate only at 1.5 to 2.5 gal/sq. Maximum Design Pressure: -45 psf. (See General Limitation #9) NOA No.: 13-0311.05 Expiration Date: 05/16/17 Approval Date: 07/18/13 Page 34 of 35 RECOVER SYSTEM LIMITATIONS: 1. All System Limitations and General Limitations shall apply. See specific deck type Notice of Acceptance for deck type System Limitations. • GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x T maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each sidelap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf.. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117 and/or RAS 137. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs • shall conform with Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 9N-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 13-0311.05 Expiration Date: 05/16/17 Approval Date: 07/18/13 Page 35 of 35