Sika Sarnafil, A Division of Sika Corp.
100 Dan Road
Canton, MA 02021
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -
Product Control Section to be used in Miami Dade County and other areas where allowed by the
Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County
Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade
County) reserve the right to have this product or material tested for quality assurance purposes. If
this product or material fails to perform in the accepted manner, the manufacturer will incur the
expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such
product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it
is determined by Miami -Dade County Product Control Section that this product or material fails to
meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building
Code including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Sika Sarnafil PVC Single Ply Roofing over Recover Deck.
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state
and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted
herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has
been no change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or
change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an
endorsement of any product, for sales, advertising or any other purposes shall automatically terminate
this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of
NOA.
ADVERTISEMENT: The NOA" number preceded by the words Miami -Dade County, Florida, and
followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is
displayed, then it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA No. 12-0313.18 and consists of pages 1 through 35.
The submitted documentation was reviewed by Jorge L. Acebo.
NOA No.: 13-0311.05
MIAMI•DADE COUNTY Expiration Date: 05/16/17
° Approval Date: 07/18/13
Page 1 of 35
ROOFING SYSTEM APPROVAL
- Category:
Roofing
Sub -Category:
Single Ply
Material:
PVC
Deck Tyne:
Recover
Maximum Design Pressure: See Specific Assemblies
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
.
Test
Product
Product
Dimensions Specification
Description
G410 Felt
Various ASTM D 4434
Fiberglass reinforced PVC roofing
membrane with a non -woven felt backing.
G459
Various ASTM D 4434
Fiberglass reinforced PVC Alloy asphalt
compatible flashing membrane.
Sarnaclad
Various Proprietary
Heat weldable PVC laminated to
galvanized steel flashing product.
Sarnaco12121
5 gallons Proprietary
Water based bonding adhesive.
Sarnaco12170
5 gallons Proprietary
Solvent based bonding adhesive.
Sarnacol 2163
Proprietary
Insulation adhesive.
Sarnastack
Various Proprietary
Prefabricated cone flashing.
Sarnatape
Various Proprietary
Air flow barrier tape.
Sarnatred
3.25' x 32.8' Proprietary
PVC walkway protection sheet.
Sarnavap-10
20' x 100' Proprietary
Polyethylene air/vapor barrier.
SarnaWalkways
Various Proprietary
PVC walkway protection sheet.
APPROVED INSULATIONS:
TABLE 2
Product
Manufacturer
Product
Description
(With Current NOA)
Sarnatherm
Isocyanurate Insulation
Sika Sarnafil, A Division
of Sika Corp.
Sarnatherm 25 PSI
Polyisocyanurate insulation board. Sika Sarnafil, A Division
of Sika Corp.
EPS
Type IX Expanded polystyrene with a Generic
_
minimum density of 1.8 pcf
- XPS
Type IV Extruded polystyrene with a Generic
minimum density of 1.6 pcf
- High Density Wood
Wood fiber insulation
Generic
Fiberboard
Perlite Insulation Board
Perlite Insulation
Generic
Type X Gypsum
Gypsum Wallboard
Generic
NOA No.: 13-0311.05
Expiration Date: 05/16/17
Approval Date: 07/18/13
Page 2 of 35
Product
Manufacturer
Product
Description
(With Current NOA)
DensDeck, DensDeck Prime
Silicon treated gypsum
Georgia Pacific Gypsum LLC
H-Shield
Isocyanurate Insulation
Hunter Panels, LLC
ENRGY 3, JM ISO 3
Isocyanurate Insulation
Johns Manville Corp.
ENRGY 3 Plus
Isocyanurate Insulation with wood
Johns Manville Corp.
fiberboard facer
ENRGY 3 25 PSI
Isocyanurate Insulation
Johns Manville Corp.
ACFoam-II
Isocyanurate Insulation
Atlas Roofing Corp.
ACFoam-III
Isocyanurate Insulation
Atlas Roofing Corp.
ACFoam Composite
Isocyanurate Insulation with perlite facer
Atlas Roofing Corp.
ACFoam Supreme
Isocyanurate Insulation
Atlas Roofing Corp.
Multi-Max-3,
Isocyanurate Insulation
Rmax Operating, LLC
Multi -Max FA-3
Thermaroof Composite-3
Isocyanurate Insulation with perlite
facer
Rmax Operating, LLC
Thermaroof-3
Isocyanurate Insulation
Rmax Operating, LLC
ISO 95+ GL
Isocyanurate Insulation
Firestone Building Products
Company, LLC
APPROVED FASTENERS:
TABLE 3
Fastener Product
Product
Manufacturer
Number Name
Description
Dimensions
(With Current NOA)
1. Dekfast 12, 14 & 15 HS
Insulation fastener for wood,
SFS Intec, Inc.
. steel and concrete decks
2. Dekfast Galvalume Steel Galvalume hex stress plate.
2 7/8" x
SFS Intec, Inc.
Hex
3 1/4"
3. Dekfast Dekflat Round
Polypropylene locking plate.
3" x 3 1/4"
SFS Intec, Inc.
Plastic Lock Plate
4. #12 Standard Roofgrip,
Insulation fastener for wood,
OMG, Inc.
#14 Roofgrip & #15
steel and concrete.
Roofgrip Fasteners
5. AccuTrac Hextra
Insulation fastener for wood,
OMG, Inc.
steel and concrete
6. Hextra Plus Pre-
Pre -assembled Insulation
OMG, Inc.
Assembled System
fastener and plate
7. OMG 3" Galvalume
Galvalume stress plate.
3" round
OMG, Inc.
Steel Plate
8. AccuTrac Plate
Galvalume stress plate.
3" square
OMG, Inc.
9. OMG Plastic Plate
Polypropylene round plate
3" round
OMG, Inc.
NOA No.: 13-0311.05
Expiration Date: 05/16/17
Approval Date: 07/18/13
Page 3 of 35
APPROVED FASTENERS:
TABLE 3
Fastener
Product
Product
Manufacturer
Number
Name
Description
Dimensions
(With Current NOA)
10.
ASAP RoofGrip Pre-
Pre -assembled Insulation
Various
OMG, Inc.
Assembled System
fastener and plate
11.
OMG G-2
3.5" round galvalume AZ55
3.5" round
OMG, Inc.
steel plate
12.
3 in. Round Metal Plate
3" round galvalume AZ50 steel
3" round
OMG, Inc.
plate
13.
OMG Super XHD
Insulation and membrane
Various
OMG, Inc.
fastener
14.
OMG Heavy Duty
Insulation and membrane
Various
OMG, Inc.
fastener
15.
CD-10
Carbon steel fastener for
Various
OMG, Inc.
concrete decks
16.
Sarnafastener
Insulation fastener for various
Various
Sika Sarnafil, A Division of
decks
Sika Corp.
17.
Sarnaplate
3" square galvalume AZ50 steel
3" square
Sika Sarnafil, A Division of
plate
Sika Corp.
18.
OMG 2" Barbed Plate
Galvalume steel plate
2" round
OMG, Inc.
19.
Dekfast System ES #12
Pre -assembled Insulation
Various
SFS Intec, Inc.
Plastic
fastener and plate
20.
Dekfast Isofast IF/IG-C-
Galvalume steel plate
1.5" x 3.2"
SFS Intec, Inc.
82X40
21.
Sarnarail Polymer Batten
Polymer batten bar
0.75" x 250'
Sika Sarnafil, A Division of
Strip
Sika Corp.
22.
Sarnafastener-XP
Membrane and insulation
Various
Sika Sarnafil, A Division of
fastener.
Sika Corp.
23.
Sarnafil MAXLoad,
Membrane and insulation
Various
Sika Sarnafil, A Division of
Sarnafastener MAXLoad
fastener.
Sika Corp.
24.
Sarnadisc XPN
Membrane and insulation
1.5" x 3.75"
Sika Sarnafil, A Division of
fastener.
Sika Corp.
25.
RhinoBond Insulation
Membrane fastening plate
Various
OMG, Inc.
Plate
26.
OMG Purlin
Membrane and insulation
Various
OMG, Inc.
fastener
27.
Sarnabar
Galvanized or stainless steel
Various
Sika Sarnafil, A Division of
membrane fastening bar.
Sika Corp.
28.
Sarnadisc MAXLoad
AZ50 galvalume coated steel
3.5" Round
Sika Sarnafil, A Division of
Plate
plate
Sika Corp.
29.
3 in. Ribbed Galvalume
Round Galvalume plated steel
3" Round
OMG, Inc.
Plate
stress plate
30.
#15 Roofgrip Large
Carbon Steel Fastener
Various
OMG, Inc.
Head
NOA No.: 13-0311.05
Expiration Date: 05/16/17
Approval Date: 07/18/13
Page 4 of 35
ti
EVIDENCE SUBMITTED:
Test Agency
Test Identifier
Description
Date
Celotex Technical Center
MTS Job No. 258215
TAS 114
09/09/97
Factory Mutual Research
OX3A3.AM
FM 4470
07/31/94
Corporation
OP6A6.AM
FM 4470
03/03/94
2X2A5.AM
FM 4470
07/31/94
OB9AO.AM
FM 4470
10/22/96
1Z5A6.AM
FM 4470
07/18/97
4B3A2.AM
FM 4470
06/19/97
1B7A5.AM
FM 4470
02/23/98
3001580
FM 4470
11/16/98
3003337
FM 4470
06/11/99
3012964
FM 4470
06/11/02
3015643
FM 4470
12/06/02
3016201
FM 4470
01/28/03
3006785
FM 4470
05/06/04
3017292
FM 4470
09/03/04
3024229
FM 4470
11/16/05
3030053
FM 4470
09/12/07
3028309
FM 4470
03/30/07
3029404
FM 4470
09/09/08
Underwriters Laboratories, Inc.
R8992
UL 790
05/15/13
Trinity I ERD
S44790.06.13
ASTM D4434
06/05/13
S42480.08.12
Physical Properties
08/20/12
NOA No.: 13-0311.05
MIAMI•DADE COUNTY Expiration Date: 05/16/17
• Approval Date: 07/18/13
Page 5 of 35
APPROVED ASSEMBLIES
Membrane Type: PVC
Deck Type 7I: Recover, Insulated
Deck Description: Concrete/lightweight concrete/cementitious wood fiber/wood/steel
System Type A(1): One or more layers of insulation fully adhered with approved asphalt, membrane
adhered
All General. and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
Vapor Retarder: (Optional) An FM approved vapor retarder approved for use with hot asphalt may
be applied to the deck or base insulation layer
Fire Barrier: (Optional) Minimum 1/4" Type X Gypsum or DensDeck
One or more layers of any of the following insulations:
Insulation Layer: Insulation Fasteners Fastener
(Table 3) Density/ft2
ACFoam-II, ACFoam-III, ACFoam Composite (bottom layer only), ACFoam Supreme, H-Shield
(bottom layer only) any of the above tapered
Minimum 1.31' thick N/A N/A
ENRGY 3, ENRGY 3 Plus, ENRGY 3 25 PSI
Minimum 1.4" thick or tapered N/A N/A
DensDeck, DensDeck Prime
Minimum'/" thick N/A N/A
Multi -Max FA-3, Thermaroof-3
Minimum 1.25" thick or tapered N/A N/A
Sarnatherm, Sarnatherm-25 PSI
Minimum 1.4" thick or tapered N/A N/A
Approved High Density Wood Fiberboard
Minimum 1" thick N/A N/A
ISO 95+ GL
Minimum 1.4" thick or tapered N/A N/A
Approved Perlite (base layer only)
Minimum %11 thick N/A N/A
Note: Existing roof shall be primed with ASTM D 41 asphalt primer and allowed to dry prior to
application of insulation. All insulation shall be adhered to the deck in full mopping of approved
asphalt within the EVT range and at a rate of 20-401bs/100 ft2 Please refer to Roofing Application
Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used
only as base layers with a second layer of approved top layer insulation installed as the final
membrane substrate. Composite insulation panels used as a top layer shall be placed with the
polyisocyanurate side facing down.
NOA No.: 13-0311.05
Expiration Date: 05/16/17
Approval Date: 07/18/13
Page 6 of 35
Membrane: G410 Felt adhered with Sarnacol 2170 applied at 1.25 gal./sq. to the substrate and
0.5 gal./sq. to the back of the Membrane, or Sarnacol 2121 applied to the substrate
only at 1.5 to 2.5 gal./sq.
Maximum Design
Pressure: -45 psf. (See General Limitation #9)
NOA No.: 13-0311.05
MIAMI•DADE COUNTY Expiration Date: 05/16/17
"' • • Approval Date: 07/18/13
Page 7 of 35
Membrane Type: PVC
Deck Type 7I: Recover, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank
System Type A(2): One or more layers of insulation adhered with approved adhesive, membrane
fully adhered
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more layers of the following insulations:
Base Insulation Layer: Insulation Fasteners Fastener
(Table 3) Density/ft2
ACFoam-II, H-Shield, ENRGY 3, ISO 95+ GL, Sarnatherm
Minimum 1" thick N/A N/A
DensDeck, DensDeck Prime
Minimum 0.25" thick N/A N/A
Top Insulation Layer: Insulation Fasteners Fastener
(Table 3) Density/ft2
DensDeck, DensDeck Prime
Minimum 0.25" thick N/A N/A
Note: All insulation shall be adhered to the deck in full coating of OlyBond Adhesive Fastener at
a rate of 1 gal/sq. Please refer to Roofing Application Standard RAS 117 for insulation
attachment. Insulation listed as base layer only shall be used only as base layers with a second
layer of approved top layer insulation installed as the final membrane substrate.
Membrane: G410 Felt adhered with Sarnaco12121 adhesive applied at 2.25 gal/sq. to the
Option #1 insulation using a'/a" x'/a" notched squeegee or Sarnaco12170 adhesive rolled
applied as a primer at a rate 1.0-1.25 gal/sq. to the insulation allowed to dry.
Following a second coat roller applied of adhesive at 1.0 gal/sq. The roof
cover is immediately placed into the adhesive and the top surface rolled with a
weighted roller.
Maximum Design Pressure, -150 psf. (See General Limitation #9)
Option #2 G410 Felt adhered with Sarnacol 2170 adhesive. Adhesive rolled applied as a
primer at a rate 1.0-1.25 gal/sq. to the insulation allowed to dry. Following a
second coat roller applied of adhesive at 0.5 gal/sq. The roof cover is
immediately placed into the adhesive and the top surface rolled with a weighted
roller.
Maximum Design Pressure; -127.5 psf. (See General Limitation #9)
• Maximum Design
Pressure: See Membrane Options above.
NOA No.: 13-0311.05
Expiration Date: 05/16/17
Approval Date: 07/18/13
Page 8 of 35
Membrane Type: PVC
Deck Type 7I: Recover, Insulated
Deck Description: Steel / concrete / cementitious wood fiber / lightweight concrete / gypsum / wood
System Type A(3): One or more layers of insulation adhered with approved adhesive, membrane fully
adhered.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
Vapor Retarder: (Optional) An FM approved vapor retarder approved for use with hot asphalt may
be applied to the deck or base insulation layer
Fire Barrier: (Optional) Minimum 1/4" Type X Gypsum or DensDeck
One or more layers of any of the following insulations:
Base Insulation Layer: Insulation Fasteners Fastener Density/ft2
(Table 3)
ACFoam-II, ACFoam-III, ISO 95+ GL, ENRGY 3, Sarnatherm
Maximum 1" thick
DensDeck, DensDeck Prime
Minimum 5/8" thick
N/A N/A
N/A N/A
Note: Insulation shall be adhered to the deck in full coating of OlyBond Adhesive Fastener at a
rate of 1 gal/sq. Please refer to Roofing Application Standard RAS 117 for insulation attachment.
Insulation listed as base layer only shall be used only as base layers with a second layer of
approved top layer insulation installed as the final membrane substrate
Membrane: G410 Felt adhered with Sarnacol 2170 applied at 1.25 gal./sq. to the
substrate and 0.5 gal./sq. to the back of the membrane, or Sarnacol 2121
applied to the substrate only at 1.5 to 2.5 gal./sq.
Maximum Design
Pressures: -45 psf. (See General Limitation #9)
NOA No.: 13-0311.05
MIAMI•DADE COUNTY Expiration Date: 05/16/17
a .. i Approval Date: 07/18/13
.Page 9 of 35
Membrane Type: PVC
Deck Type 7I: Recover, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank
System Type A(4): One or more layers of insulation adhered with approved adhesive, membrane
fully adhered
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more layers of the following insulations:
Base Insulation Layer (Optional): Insulation Fasteners Fastener
(Table 3) Density/ft2
Approved EPS
Minimum 2" thick N/A N/A
Top Insulation Layer: Insulation Fasteners Fastener
(Table 3) Density/ft2
Approved High Density Wood Fiberboard
Minimum 1" thick N/A N/A
DensDeck, DensDeck Prime
Minimum 0.25" thick N/A N/A
Note: All insulation shall be adhered to the deck in 3/" —1" wide beads 12" o.c. of OlyBond 500
or Spot Shot Adhesive Fastener. Please refer to Roofing Application Standard RAS 117 for
insulation attachment. Insulation listed as base layer only shall be used only as base layers with a
second layer of approved top layer insulation installed as the final membrane substrate.
Membrane: G410 Felt adhered with Sarnacol 2121 adhesive applied at 2.25 gal/sq. to the
insulation using a'/" x'/4" notched squeegee.
Or
Maximum Design
Pressure:
G410 Felt adhered with Sarnacol 2170 adhesive. Adhesive rolled applied as a
primer at a rate 1.0-1.25 gal/sq. to the insulation allowed to dry. Following a
second coat roller applied of adhesive at 0.5 gal/sq. The roof cover is
immediately placed into the adhesive and the top surface rolled with a weighted
roller.
-120 psf. (See General Limitation #9)
NOA No.: 13-0311.05
Expiration Date: 05/16/17
Approval Date: 07/18/13
Page 10 of 35
Membrane Type: PVC
Deck Type 7I: Recover, Insulated
Deck Description: Cementitious wood fiber / Gypsum
System Type A(5): One or more layers of insulation adhered with approved adhesive, membrane fully
adhered.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
Base Insulation Layer: Insulation Fasteners Fastener
(Table 3) - Density/ft2
ACFoam-II, H-Shield, ENRGY 3, Sarnatherm
Minimum 1" thick N/A N/A
DensDeck, DensDeck Prime
Minimum 0.25" thick N/A N/A
Top Insulation Layer: Insulation Fasteners Fastener
Density/ft2
DensDeck, DensDeck Prime
Minimum 0.25" thick N/A N/A
Note: All insulation shall be adhered to the deck in full coating of OlyBond Adhesive Fastener at
a rate of 1 gal/sq. Please refer to Roofing Application Standard RAS 117 for insulation
attachment. Insulation listed as base layer only shall be used only as base layers with a second
layer of approved top layer insulation installed as the final membrane substrate.
Membrane: G410 Felt adhered with Sarnacol 2170 applied at 1.25 gal./sq. to the
substrate and 0.5 gal./sq. to the back of the Membrane, or Sarnacol 2121
applied to the substrate only at 1.5 to 2.5 gal./sq.
Maximum Design
Pressure:
MIAMI•DADE COUNTY
•
-45 psf. (See General Limitation #9)
NOA No.: 13-0311.05
Expiration Date: 05/16/17
Approval Date: 07/18/13
Page 11 of 35
Membrane Type: PVC
Deck Type 7I: Recover, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank
System Type A(6): One or more layers of insulation adhered with approved adhesive, membrane
fully adhered
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more layers of the following insulations:
Base Insulation Layer (Optional): Insulation Fasteners Fastener
(Table 3) Density/ft2
ACFoam-II, H-Shield, Sarnatherm
Minimum 1.5" thick N/A N/A
Top Insulation Layer: Insulation Fasteners Fastener
(Table 3) Density/ft2
DensDeck, DensDeck Prime
Minimum 0.25" thick N/A N/A
Note: All insulation shall be adhered to the deck in V —1" wide beads 12" o.c. of OlyBond 500
or Spot Shot Adhesive Fastener. Please refer to Roofing Application Standard RAS 117 for
insulation attachment. Insulation listed as base layer only shall be used only as base layers with a
second layer of approved top layer insulation installed as the final membrane substrate.
Membrane: G410 Felt adhered with Sarnacol 2121 adhesive applied at 2.25 gal/sq. to the
insulation using a'/a" x'/4" notched squeegee or Sarnacol 2170 adhesive rolled
applied as a primer at a rate 1.0-1.25 gal/sq. to the insulation allowed to dry.
Following a second coat roller applied of adhesive at 1.0 gal/sq. The roof
cover is immediately placed into the adhesive and the top surface rolled with a
weighted roller.
Or
Maximum Design
Pressure:
MIAMI-DADE COUNTY
LIUMIMI
G41-0 Felt adhered with Sarnacol 2170 adhesive. Adhesive rolled applied as a
primer at a rate 1.0-1.25 gal/sq. to the insulation allowed to dry. Following a
second coat roller applied of adhesive at 0.5 gal/sq. The roof cover is
immediately placed into the adhesive and the top surface rolled with a weighted
roller.
-120 psf. (See General Limitation #9)
NOA No.: 13-0311.05
Expiration Date: 05/16/17
Approval Date: 07/18/13
Page 12 of 35
Membrane Type: PVC
Deck Type 7I:. Recover, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank
System Type A(7): One or more layers of insulation adhered with approved adhesive, membrane
fully adhered
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more layers of the following insulations:
Base Insulation Layer: Insulation Fasteners Fastener
(Table 3) Density/ft2
ENRGY 3, Sarnatherm, H-Shield
Minimum 1.5" thick N/A N/A
Top Insulation Layer: Insulation Fasteners Fastener
(Table 3) Density/ft2
DensDeck, DensDeck Prime
Minimum 0.25" thick N/A N/A
Note: All insulation shall be adhered to the deck in %'1 — 1" wide beads 12" o.c. of OlyBond 500
or Spot Shot Adhesive Fastener. Please refer to Roofing Application Standard RAS 117 for
insulation attachment. Insulation listed as base layer only shall be used only as base layers with a
second layer of approved top layer insulation installed as the final membrane substrate.
Membrane: G410 Felt adhered with Sarnacol 2121 adhesive applied at 2.25 gal/sq. to the
insulation using a'/4" x'/4" notched squeegee or Sarnacol 2170 adhesive rolled
applied as a primer at a rate 1.0-1.25 gal/sq. to the insulation allowed to dry.
Following a second coat roller applied of adhesive at 1.0 gal/sq. The roof
cover is immediately placed into the adhesive and the top surface rolled with a
weighted roller.
Or
G410 Felt adhered with Sarnacol 2170 adhesive. Adhesive rolled applied as a
primer at a rate 1.0-1.25 gal/sq. to the insulation allowed to dry. Following a
_ second coat roller applied of adhesive at 0.5 gal/sq. The roof cover is
immediately placed into the adhesive and the top surface rolled with a weighted
roller.
Maximum Design
Pressure:
-120 psf. (See General Limitation #9)
NOA No.: 13-0311.05
Expiration Date: 05/16/17
Approval Date: 07/18/13
Page 13 of 35
Membrane Type: PVC
Deck Type 7I: Recover, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank
System Type A(8): One or more layers of insulation adhered with approved adhesive, membrane
fully adhered
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more layers of the following insulations:
Base Insulation Layer: Insulation Fasteners Fastener
(Table 3) Density/ft2
ISO 95+ GL, H-Shield
Minimum 1.5" thick N/A N/A
Top Insulation Layer: Insulation Fasteners Fastener
(Table 3) Density/ft2
Approved High Density Wood Fiberboard
Minimum 1" thick N/A N/A
Note: All insulation shall be adhered to the deck in %11-1" wide beads 12" o.c. of OlyBond 500
or Spot Shot Adhesive Fastener. Please refer to Roofing Application Standard RAS 117 for
insulation attachment. Insulation listed as base layer only shall be used only as base layers with a
second layer of approved top layer insulation installed as the final membrane substrate.
Membrane: G410 Felt adhered with Sarnacol 2121 adhesive applied at 2.25 gal/sq. to the
insulation using all/4" x'/a" notched squeegee.
Maximum Design
Pressure: -120 psf. (See General Limitation #9)
NOA No.: 13-0311.05
MIAMI•DADE COUNTY Expiration Date: 05/16/17
' ' ' Approval Date: 07/18/13
Page 14 of 35
Membrane Type: PVC
Deck Type 7I: Recover, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank
System Type A(9): One or more layers of insulation adhered with approved adhesive, membrane
fully adhered ,
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more layers of the following insulations:
Base Insulation Layer: Insulation Fasteners Fastener
(Table 3) Density/ft2
Approved XPS
Minimum V thick N/A N/A
Top Insulation Layer: Insulation Fasteners Fastener
(Table 3) Density/ft2
DensDeck, DensDeck Prime
Minimum 0.25" thick N/A N/A
Note: All insulation shall be adhered to the deck in %'1-1" wide beads 12" o.c. of OlyBond 500
or Spot Shot Adhesive Fastener. Please refer to Roofing Application Standard RAS 117 for
insulation attachment. Insulation listed as base layer only shall be used only as base layers with a
second layer of approved top layer insulation installed as the final membrane substrate.
Membrane: G410 Felt adhered with Sarnaco12121 adhesive applied at 2.25 gal/sq. to the
insulation using a'/4" x'/4" notched squeegee or Sarnaco12170 adhesive rolled
applied as a primer at a rate 1.0-1.25 gal/sq. to the insulation allowed to dry.
Following a second coat roller applied of adhesive at 1.0 gal/sq. The roof
cover is immediately placed into the adhesive and the top surface rolled with a
weighted roller.
Or
G410 Felt adhered with Sarnaco12170 adhesive. Adhesive rolled applied as a
primer at a rate 1.0-1.25 gal/sq. to the insulation allowed to dry. Following a
second coat roller applied of adhesive at 0.5 gal/sq. The roof cover is
immediately placed into the adhesive and the top surface rolled with a weighted
roller.
Maximum Design
Pressure: -120 psf. (See General Limitation #9)
NOA No.: 13-0311.05
Expiration Date: 05/16/17
Approval Date: 07/18/13
Page 15 of 35
Membrane Type: PVC
Deck Type 7I: Recover, Insulated
Deck Description: Min. 200 psi lightweight insulating concrete
System Type A(10): One or more layers of insulation adhered with approved adhesive, membrane
fully adhered
+ All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more layers of the following insulations:
Base Insulation Layer: Insulation Fasteners Fastener
(Table 3) Density/ft2
ACFoam-H, H-Shield, Sarnatherm
Minimum 1.5" thick N/A N/A
Approved High Density Wood Fiberboard
Minimum 0.5" thick N/A N/A
DensDeck, DensDeck Prime
Minimum 0.25" thick N/A N/A
Top Insulation Layer: Insulation Fasteners Fastener
(Table 3) Density/ft2
Approved High Density Wood Fiberboard
Minimum 1" thick N/A N/A
DensDeck, DensDeck Prime
Minimum 0.25" thick N/A N/A
Note: All insulation shall be adhered to the deck in %1' —1" wide beads 12" o.c. of OlyBond 500
or Spot Shot Adhesive Fastener. Please refer to Roofing Application Standard RAS 117 for
insulation attachment. Insulation listed as base layer only shall be used only as base layers with a
second layer of approved top layer insulation installed as the final membrane substrate.
Membrane: G410 Felt adhered with Sarnacol 2121 adhesive applied at 2.25 gal/sq. to the
insulation using a'/4" x'/4" notched squeegee.
Or
Sarnaco12170 adhesive rolled applied as a primer at a rate 1.0-1.25 gal/sq. to
the insulation allowed to dry. Following a second coat roller applied of
adhesive at 1.0 gal/sq. The roof cover is immediately placed into the adhesive
and the top surface rolled with a weighted roller.
Maximum Design
Pressure: -120 psf. (See General Limitation #9)
NOA No.: 13-0311.05
MIAMI•DADE COUNTY Expiration Date: 05/16/17
Approval Date: 07/18/13
Page 16 of 35
Membrane Type: PVC
Deck Type 7I: Recover, Insulated
Deck Description: Lightweight insulating concrete
System Type A(11): One or more layers of insulation adhered with approved adhesive, membrane
fully adhered
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more layers of the following insulations:
Insulation Layer: Insulation Fasteners Fastener
(Table 3) Density/ft2
ACFoam-II, H-Shield, ENRGY 3, Sarnatherm
Minimum 1" thick or tapered N/A N/A
Note: All insulation shall be adhered to the deck in V —1" wide beads 12" o.c. of OlyBond 500
or Spot Shot Adhesive Fastener. Please refer to Roofing Application Standard RAS 117 for
insulation attachment. Insulation listed as base layer only shall be used only as base layers with a
second layer of approved top layer insulation installed as the final membrane substrate.
Membrane: G410 Felt adhered with Sarnacol 2121 adhesive applied at 2.25 gal/sq. to the
insulation using a'/4" x'/a" notched squeegee.
Or
G410 Felt adhered with Sarnacol 2170 adhesive. Adhesive rolled applied as a
primer at a rate 1.0-1.25 gal/sq. to the insulation allowed to dry. Following a
second coat roller applied of adhesive at 0.5 gal/sq. The roof cover is
immediately placed into the adhesive and the top surface rolled with a weighted
roller.
Maximum Design
Pressure: -90 psf. (See General Limitation #9)
NOA No.: 13-0311.05
Expiration Date: 05/16/17
Approval Date: 07/18/13
Page 17 of 35
Membrane Type: PVC
Deck Type 7I: Recover, Insulated
Deck Description: Gypsum
System Type A(12): One or more layers of insulation adhered with approved adhesive, membrane
fully adhered
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more layers of the following insulations:
Insulation Layer: Insulation Fasteners Fastener
(Table 3) Density/ft2
ACFoam-II, H-Shield, ENRGY 3, Sarnatherm
Minimum 1.5" thick N/A N/A
Note: All insulation shall be adhered to the deck in '/" —1" wide beads 12" o.c. of OlyBond 500
or Spot Shot Adhesive Fastener. Please refer to Roofing Application Standard RAS 117 for
insulation attachment. Insulation listed as base layer only shall be used only as base layers with a
second layer of approved top layer insulation installed as the final membrane substrate.
Membrane: G410 Felt adhered with Sarnacol 2170 adhesive. Adhesive rolled applied as a
primer at a rate 1.0-1.25 gal/sq. to the insulation allowed to dry. Following a
second coat roller applied of adhesive at 0.5 gal/sq. The roof cover is
immediately placed into the adhesive and the top surface rolled with a weighted
roller.
Or
G410 Felt adhered with Sarnacol 2121 adhesive applied at 2.25 gal/sq. to the
insulation using a'/" x'/4" notched squeegee.
Maximum Design
Pressure: -112.5 psf. (See General Limitation #9)
NOA No.: 13-0311.05
Expiration Date: 05/16/17
Approval Date: 07/18/13
Page 18 of 35
Membrane Type: PVC
Deck Type 7I: Recover, Insulated
Deck Description: Gypsum
System Type A(13): One or more layers of insulation adhered with approved adhesive, membrane
fully adhered
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
One or more layers of the following insulations:
Insulation Layer: Insulation Fasteners Fastener
(Table 3) Density/ft2
Approved High Density Wood Fiberboard
Minimum 0.5" thick N/A N/A
Note: All insulation shall be adhered to the deck in %1' —1" wide beads 12" o.c. of OlyBond 500
or Spot Shot Adhesive Fastener. Please refer to Roofing Application Standard RAS 117 for
insulation attachment. Insulation listed as base layer only shall be used only as base layers with a
second layer of approved top layer insulation installed as the final membrane substrate.
Membrane: G410 Felt adhered with Sarnacol 2121 adhesive applied at 2.25 gal/sq. to the
insulation using a''/a" x'/" notched squeegee.
Maximum Design
Pressure: -135 psf. (See General Limitation #9)
NOA No.: 13-0311.05
Expiration Date: 05/16/17
Approval Date: 07/18/13
Page 19 of 35
Membrane Type: PVC
Deck Type 7I: Recover, Insulated
Deck Description: Gypsum
System Type A(14): One or more layers of insulation adhered with approved adhesive, membrane fully
adhered
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not
approved and shall not be installed unless said accessories demonstrate compliance with prescriptive
Florida Building Code requirements and are field fabricated utilizing the approved membranes
listed in Table 1.
Vapor Retarders: (Optional) Any UL or FM approved asphaltic vapor retarder may be installed
over the deck or the base layer of insulation
One or more layers of the following insulations:
Base Insulation Layer (Optional): Insulation Fasteners Fastener
(Table 3) Density/ft2
ACFoam-II, ACFoam-III, H-Shield, ISO 95+ GL, ENRGY 3, Multi-Max-3, Sarnatherm
Minimum 1.5" thick or tapered N/A N/A
Top Insulation Layer: Insulation Fasteners Fastener
(Table 3) Density/ft2
DensDeck, DensDeck Prime
Minimum 0.25" thick N/A N/A
Approved High Density Wood Fiberboard
Minimum 0.5" thick N/A N/A
Note: All insulation shall be adhered to the deck in '/2" to %11 wide beads 12" o.c. of Millennium
One Step Foamable Adhesive or Sarnacol 2163. Please refer to Roofing Application Standard RAS
117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers
with a second layer of approved top layer insulation installed as the final membrane substrate.
Membrane: G410 Felt adhered with Sarnacol 2121 adhesive applied at 2.25 gal/sq. to the
insulation using a''/4" x'/4" notched squeegee or Sarnacol 2170 adhesive rolled
applied as a primer at a rate 1.0-1.25 gal/sq. to the insulation allowed to dry.
Following a second coat roller applied of adhesive at 1.0 gal/sq. The roof cover is
immediately placed into the adhesive and the top surface rolled with a weighted
roller.
Or
G410 Felt adhered with Sarnacol 2121 adhesive applied at 2.25 gal/sq. to the
insulation using a'/4" x'/4" notched squeegee.
• Maximum Design
Pressure: -45 psf. (See General Limitation #9)
NOA No.: 13-0311.05
Expiration Date: � 05/16/17
Approval Date: 07/18/13
Page 20 of 35
Membrane Type: PVC
Deck Type 7I: Recover, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank
System Type A(15): One or more layers of insulation adhered with approved adhesive, membrane fully
adhered
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not
approved and shall not be installed unless said accessories demonstrate compliance with prescriptive
Florida Building Code requirements and are field fabricated utilizing the approved membranes -
listed in Table 1.
Vapor Retarders: (Optional) Any UL or FM approved asphaltic vapor retarder may be installed
over the deck or the base layer of insulation
One or more layers of the following insulations:
Insulation Layer: Insulation Fasteners Fastener
(Table 3) Density/ft2
ACFoam-II, Multi-Max-3, ENRGY 3, H-Shield, Sarnatherm
Minimum 1.5" thick N/A N/A
DensDeck, DensDeck Prime
Minimum 0.25" thick N/A N/A
Note: All insulation shall be adhered to the deck in '/" to %" wide beads 12" o.c. of Millennium
One Step Foamable Adhesive or Sarnaco12163. Please refer to Roofing Application Standard RAS
117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers
with a second layer of approved top layer insulation installed as the final membrane substrate.
Membrane: G410 Felt adhered with Sarnacol 2121 adhesive applied at 2.25 gal/sq. to the
Option #1 insulation using a'/4" x'/4" notched squeegee or Sarnacol 2170 adhesive rolled
applied as a primer at a rate 1.0-1.25 gal/sq. to the insulation allowed to dry.
Following a second coat roller applied of adhesive at 1.0 gal/sq. The roof cover is
immediately placed into the adhesive and the top surface rolled with a weighted
roller.
Maximum Design Pressure; -157.5 psf. (See General Limitation #9
Option #2 G410 Felt adhered with Sarnacol 2170 adhesive. Adhesive rolled applied as a
primer at a rate 1.0-1.25 gal/sq. to the insulation allowed to dry. Following a
second coat roller applied of adhesive at 0.5 gal/sq. The roof cover is
immediately placed into the adhesive and the top surface rolled with a weighted
roller.
Maximum Design Pressure, -127.5 psf. (See General Limitation #9)
Maximum Design
Pressure: See membrane options above.
NOA No.: 13-0311.05
Expiration Date: 05/16/17
Approval Date: 07/18/13
Page 21 of 35
Membrane Type: PVC
Deck Type 7I: Recover, Insulated
• Deck Description: Min. 2500 psi structural concrete or concrete plank
System Type A(16): One or more layers of insulation adhered with approved adhesive, membrane fully
adhered
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not
approved and shall not be installed unless said accessories demonstrate compliance with prescriptive
Florida Building Code requirements and are field fabricated utilizing the approved membranes
listed in Table 1.
Vapor Retarders: (Optional) Any UL or FM approved asphaltic vapor retarder may be installed
over the deck or the base layer of insulation
One or more layers of the following insulations:
Base Insulation Layer: Insulation Fasteners Fastener
(Table 3) Density/fe
ACFoam-II, Multi-Max-3, ENRGY 3, H-Shield, ISO 95+ GL, Sarnatherm
Minimum 1.5" thick N/A N/A
Top Insulation Layer: Insulation Fasteners Fastener
(Table 3) Density/fe
Approved High Density Wood Fiberboard
Minimum 0.5" thick N/A N/A
Note: All insulation shall be adhered to the deck in 1/" to %" wide beads 12" o.c. of Millennium
One Step Foamable Adhesive Sarnacol 2163 or Millennium Pourable Foam Insulation Adhesive.
Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as
base layer only shall be used only as base layers with a second layer of approved top layer insulation
installed as the final membrane substrate.
Membrane: G410 Felt adhered with Sarnacol 2121 adhesive applied at 2.25 gal/sq. to the
insulation using a'/4" x'/4" notched squeegee.
.Maximum Design , '
Pressure: -127.5 psf. (See General Limitation #9)
NOA No.: 13-0311.05
MIAMI•DADECOUNTY Expiration Date: 05/16/17
�Lll'"Yjqlj Approval Date: 07/18/13
Page 22 of 35
Membrane Type: PVC
Deck Type 7I: Recover, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank
System Type A(17): One or more layers of insulation adhered with approved adhesive, membrane fully
adhered
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not
approved and shall not be installed unless said accessories demonstrate compliance with prescriptive
Florida Building Code requirements and are field fabricated utilizing the approved membranes
listed in Table 1.
Vapor Retarders: (Optional) Any UL or FM approved asphaltic vapor retarder may be installed
over the deck or the base layer of insulation
One or more layers of the following insulations:
Base Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft2
Approved XPS Insulation Boards
Minimum 1" thick N/A N/A
Top Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft2
DensDeck, DensDeck Prime
Minimum 0.25" thick N/A N/A
Note: All insulation shall be adhered to the deck in I/" to '/" wide beads 12" o.c. of Millennium
Pourable Foam Insulation Adhesive. Please refer to Roofing Application Standard RAS 117 for
insulation attachment. Insulation listed as base layer only shall be used only as base layers with a
second layer of approved top layer insulation installed as the final membrane substrate.
Membrane: G410 Felt adhered with Sarnacol 2121 adhesive applied at 2.25 gal/sq. to the
insulation using a'/" x'/a" notched squeegee or Sarnacol 2170 adhesive rolled
applied as a primer at a rate 1.0-1.25 gal/sq. to the insulation allowed to dry.
Following a second coat roller applied of adhesive at 1.0 gal/sq. The roof cover is
immediately placed into the adhesive and the top surface rolled with a weighted
roller.
Maximum Design
Pressure: -202.5 psf. (See General Limitation #9)
NOA No.: 13-0311.05
MIAMI•DADE COUNTY Expiration Date: 05/16/17
"' • • Approval Date: 07/18/13
Page 23 of 35
Membrane Type: PVC
Deck Type 7I: Recover, Insulated
• Deck Description: Min. 2500 psi structural concrete or concrete plank
System Type A(18): One or more layers of insulation adhered with approved adhesive, membrane fully
adhered
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not
approved and shall not be installed unless said accessories demonstrate compliance with prescriptive
Florida Building Code requirements and are field fabricated utilizing the approved membranes
listed in Table 1.
Vapor Retarders: (Optional) Any UL or FM approved asphaltic vapor retarder may be installed
over the deck or the base layer of insulation
One or more layers of the following insulations:
Base Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft2
Approved XPS or EPS
Minimum 1" thick N/A N/A
Top Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft2
Approved High Density Wood Fiberboard
Minimum 0.5" thick N/A N/A
Note: All insulation shall be adhered to the deck in lh" to '/" wide beads 12" o.c. of Millennium
Pourable Foam Insulation Adhesive. Please refer to Roofing Application Standard RAS 117 for
insulation attachment. Insulation listed as base layer only shall be used only as base layers with a
second layer of approved top layer insulation installed as the final membrane substrate.
Membrane: G410 Felt adhered with Sarnacol 2121 adhesive applied at 2.25 gal/sq. to the
insulation using a'/4" x'/" notched squeegee.
Maximum Design -150 psf. (with EPS) (See General Limitation #9)
Pressure: -162.5 psf. (with XPS) (See General Limitation #9)
NOA No.: 13-0311.05
Expiration Date: 05/16/17
Approval Date: 07/18/13
Page 24 of 35
Membrane Type: PVC
Deck Type 7I: Recover, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank
System Type A(19): One or more layers of insulation adhered with approved adhesive, membrane fully
adhered
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not
approved and shall not be installed unless said accessories demonstrate compliance with prescriptive
Florida Building Code requirements and are field fabricated utilizing the approved membranes
listed in Table 1.
Vapor Retarders: (Optional) Any UL or FM approved asphaltic vapor retarder may be installed
over the deck or the base layer of insulation
One or more layers of the following insulations:
Base Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft,
ACFoam II, ACFoam III, ENRGY 3, Sarnatherm, H-Shield
Minimum 1.5" thick N/A N/A
Top Insulation Layer Insulation Fasteners Fastener
(Table 3) Density/ft2
Approved High Density Wood Fiberboard
Minimum 0.25" thick N/A N/A
Note: All insulation shall be adhered to the deck in V211 to %" wide beads 12" o.c, of Millennium
Pourable Foam Insulation Adhesive. Please refer to Roofing Application Standard RAS 117 for
insulation attachment. Insulation listed as base layer only shall be used only as base layers with a
second layer of approved top layer insulation installed as the final membrane substrate.
Membrane: G410 Felt adhered with Sarnacol 2121 adhesive applied at 2.25 gal/sq. to the
insulation using a'/" x'/4" notched squeegee.
Maximum Design
Pressure:
MIAMI•DADE COUNTY
F-11...•
1411
-127.5 psf. (See General Limitation #9)
NOA No.: 13-0311.05
Expiration Date: 05/16/17
Approval Date: 07/18/13
Page 25 of 35
Membrane Type: PVC
Deck Type 7I: Recover, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank
System Type A(20): One or more layers of insulation adhered with approved adhesive, membrane
fully adhered
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
Vapor Retarders: (Optional) Any UL or FM approved vapor retarder may be installed over the
deck.
One or more layers of any of the following insulations:
Insulation Layer: Insulation Fasteners Fastener
(Table 3) Density/ft2
ACFoam-II, ACFoam-III, Multi -Max FA-3, JM ISO 3, ISO 95+GL, Sarnatherm
Minimum 1.5" thick N/A N/A
DensDeck, DensDeck Prime
Minimum 0.5" thick N/A N/A
Note: All insulation shall be adhered to the deck in 3-3.5" wide beads spaced 12" o.c. of TITE-
SET Roofing Adhesive or 3M Polyurethane Foam Insulation Adhesive CR-20. Please refer to
Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer
only shall be used only as base layers with a second layer of approved top layer insulation installed
as the final membrane substrate.
Membrane: G410 Felt adhered with Sarnacol 2121 adhesive applied at 2.25 gal/sq. to the
insulation using a''/4" x'/4" notched squeegee or with Sarnacol 2170 adhesive
rolled applied as a primer at a rate 1.0-1.25 gaUsq. to the insulation allowed to
dry. Following a second coat roller applied of adhesive at 1.0 gal/sq. The roof
cover is immediately placed into the adhesive and the top surface rolled with a
weighted roller.
Maximum Design
Pressure: -202.5 psf. (See General Limitation #9)
NOA No.: 13-0311.05
Expiration Date: 05/16/17
Approval Date: 07/18/13
Page 26 of 35
Membrane Type: PVC
Deck Type 7I: Recover, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank
System Type A(21): One or more layers of insulation adhered with approved adhesive, membrane
fully adhered
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
Vapor Retarders: (Optional) Any UL or FM approved vapor retarder may be installed over the
deck.
One or more layers of any of the following insulations:
Base Insulation Layer (Optional): Insulation Fasteners Fastener
(Table 3) Density/W
ACFoam-II, ACFoam-III, Multi -Max FA-3, JM ISO 3, ISO 95+GL, Sarnatherm, H-Shield
Minimum 1.5" thick N/A N/A
DensDeck, DensDeck Prime
Minimum 0.5" thick N/A N/A
Top Insulation Layer: Insulation Fasteners Fastener
(Table 3) Density/ft2
ACFoam-II, ACFoam-III, Multi -Max FA-3, Sarnatherm
Tapered N/A N/A
Note: All insulation shall be adhered to the deck in 3-3.5" wide beads spaced 12" o.c. of TITE-
SET Roofing Adhesive or 3M Polyurethane Foam Insulation Adhesive CR-20. Please refer to
Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer
only shall be used only as base layers with a second layer of approved top layer insulation installed
as the final membrane substrate.
Membrane: G410 Felt adhered with Sarnacol 2121 adhesive applied at 2.25 gal/sq. to the
insulation using a''/4" x'/4" notched squeegee or with Sarnaco12170 adhesive
rolled applied as a primer at a rate 1.0-1.25 gal/sq. to the insulation allowed to
dry. Following a second coat roller applied of adhesive at 1.0 gal/sq. The
roof cover is immediately placed into the adhesive and the top surface rolled
with a weighted roller.
Maximum Design
Pressure: -45 psf. (See General Limitation #9)
NOA No.: 13-0311.05
Expiration Date: 05/16/17
Approval Date: 07/18/13
Page 27 of 35
Membrane Type: PVC
Deck Type 7I: Recover, Insulated
Deck Description: Min. 2500 psi structural concrete or concrete plank
System Type A(22): One or more layers of insulation adhered with approved adhesive, membrane
fully adhered
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
Vapor Retarders: (Optional) Any UL or FM approved vapor retarder may be installed over the
deck.
One or more layers of any of the following insulations:
Insulation Layer: Insulation Fasteners Fastener
(Table 3) Density/fe
DensDeck, DensDeck Prime
Minimum 0.5" thick N/A N/A
Note: All insulation shall be adhered to the deck in 3-3.5" wide beads spaced 12" o.c. of TITE-
SET Roofing Adhesive or 3M Polyurethane Foam Insulation Adhesive CR-20. Please refer to
Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer
only shall be used only as base layers with a second layer of approved top layer insulation installed
as the final membrane substrate.
Membrane: G410 Felt adhered with Sarnacol 2121 adhesive applied at 2.25 gal/sq. to the
insulation using a'/4" x'/4" notched squeegee or with Sarnaco12170 adhesive
rolled applied as a primer at a rate 1.0-1.25 gal/sq. to the insulation allowed to
dry. Following a second coat roller applied of adhesive at 1.0 gal/sq. The roof
cover is immediately placed into the adhesive and the top surface rolled with a
weighted roller.
Maximum Design
Pressure: -202.5 psf. (See General Limitation #9)
NOA No.: 13-0311.05
Expiration Date: 05/16/17
Approval Date: 07/18/13
Page 28 of 35
Membrane Type: PVC
Deck Type 7I: Recover, Insulated
- Deck Description: Concrete/lightweight concrete/cementitious wood fiber/wood/steel
System Type B: Base layer of insulation mechanically attached, optional top layer fully adhered
with approved asphalt, membrane adhered.
' All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
Vapor Retarder: (Optional) An FM approved vapor retarder approved for use with hot asphalt may
be applied to the deck or base insulation layer
Fire Barrier: (Optional) Minimum 1/4" Type X Gypsum or DensDeck.
Base Insulation Layer: Insulation Fasteners
Fastener
(Table 3)
Density/fe
ACFoam II, ACFoam Composite, H-Shield
Minimum 1.3" thick or tapered Any approved fastener
1:2 ft2
Minimum 2" thick or tapered listed in Table 3
1:4 ft2
ENRGY-3, ENRGY 3 Plus, ENRGY 3 25 PSI
Minimum 1.4" thick or tapered Any approved fastener
1:2 ft2
Minimum 2" thick or tapered listed in Table 3
1:4 ft2
DensDeck, DensDeck Prime
Minimum'/a" thick _ Any approved fastener
1:1.2 ft2
Minimum'/z" thick listed in Table 3
1:1.7 ft2
Multi -Max FA-3, Thermaroof Composite-3
Minimum 1.25" thick or tapered Any approved fastener
1:2 ft2
Minimum 2" thick or tapered listed in Table 3
1:4 ft2
Sarnatherm, Sarnatherm-25 PSI
Minimum 1.4" thick Any approved fastener
1:2 ft2
Minimum 2" thick listed in Table 3
1:4 ft2
ISO 95+ GL
Minimum 1.4" thick or tapered Any approved fastener
1:2 ft2
Minimum 2" thick or tapered listed in Table 3
1:4 ft2
- Approved High Density Wood Fiberboard
Minimum 1" thick Any approved fastener
1:2 ft2
- listed in Table 3
Approved Perlite
- Minimum %11 thick Any approved fastener
1:2 ft2
listed in Table 3
NOA No.: 13-0311.05
Expiration Date: 05/16/17
Approval Date: 07/18/13
Page 29 of 35
Note: Base layers of insulation shall be mechanically attached using the fastener density listed.
The insulation panels listed are minimum sizes and dimensions; if larger panels are used, the
number of fasteners shall be increased maintaining the same fastener density. Insulation fasteners
shall be tested for withdrawal resistance in compliance with Protocol TAS 105 to confirm
compliance with the wind load requirements. Please refer to Roofing Application Standard RAS
117 for insulation attachment.
Top Insulation Layer (Optional): Insulation Fasteners Fastener
(Table 3) Density/ft2
ACFoam-II
Minimum 1.3" thick or tapered N/A N/A
ENRGY 3, ENRGY 3 Plus, ENRGY 3 25 PSI
Minimum 1.4" thick or tapered - N/A N/A
DensDeck, DensDeck Prime
Minimum'/4" thick N/A N/A
Multi -Max FA-3
Minimum 1.25" thick or tapered N/A N/A
Sarnatherm, Sarnatherm-25 PSI
Minimum 1.4" thick N/A N/A
ISO 95+ GL
Minimum 1.4" thick or tapered N/A N/A
Approved High Density Wood Fiberboard
Minimum 1" thick N/A N/A
Note: Optional top layer of insulation shall be adhered with approved asphalt within the EVT
range and at a rate of 20-40 lbs./100 ft2. Please refer to Roofing Application Standard RAS 117 for
insulation attachment. Composite insulation boards used as a top layer shall be installed with the
polyisocyanurate face down.
Membrane: G410 Felt adhered with Sarnacol 2170 applied at 1.25 gal./sq. to the substrate and
.5 gal./sq. to the back of the Membrane, or Sarnacol 2121 applied to the substrate
only at 1.5 to 2.5 gal./sq.
Maximum Design
Pressure: -45 psf. (See General Limitation 99)
NOA No.: 13-0311.05
Expiration Date: 05/16/17
Approval Date: 07/18/13
Page 30 of 35
Membrane Type: PVC
Deck Type 7I: Recover, Insulated
Deck Description: Concrete/lightweight concrete/cementitious wood fiber/wood/steel
System Type C(1): All layers of insulation simultaneously attached, membrane adhered.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
• not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
Vapor Retarder: (Optional) Sarnavap-10 vapor barrier applied directly to the deck or over base
insulation layer.
Fire Barrier: (Optional) Minimum 1/4" Type X Gypsum or DensDeck.
Base Insulation Layer: Insulation Fasteners Fastener
(Table 3) Density/ft2
ACFoam-II, ACFoam-III, ACFoam Composite, ACFoam Supreme, H-Shield
Minimum 1.3" thick or tapered N/A N/A
ENRGY 3, ENRGY 3 Plus, ENRGY 3 25 PSI
Minimum 1.4" thick or tapered N/A N/A
DensDeck, DensDeck Prime
Minimum'/" thick N/A N/A
Multi -Max FA-3, Thermaroof-3
Minimum 1.25" thick or tapered N/A N/A
Sarnatherm, Sarnatherm-25 PSI
Minimum 1.4" thick or tapered N/A N/A
Approved High Density Wood Fiberboard
Minimum 1" thick N/A N/A
ISO 95+ GL
Minimum 1.4" thick or tapered N/A N/A
Approved Perlite
Minimum %11 thick N/A N/A
Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density.
Insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number
of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing
Application Standard RAS 117 for insulation attachment.
NOA No.: 13-0311.05
Expiration Date: 05/16/17
Approval Date: 07/18/13
Page 31 of 35
Top Insulation Layer:
Insulation Fasteners
Fastener
(Table 3)
Density/ft2
ACFoam-II, ACFoam-III
• Minimum 1.3" thick or tapered
Any approved fastener
1:2 ft2
Minimum 2" thick or tapered
listed in Table 3
1:4 ft2
ENRGY 3, ENRGY 3 Plus, ENRGY 3 25 PSI
Minimum 1.4" thick or tapered
Any approved fastener
1:2 ft2
Minimum 2" thick or tapered
listed in Table 3
1:4 ft2
DensDeck, DensDeck Prime
Minimum'/4" thick
Any approved fastener
1:1.2 ft2
Minimum V2" thick
listed in Table 3
1:1.7 ft2
Sarnatherm, Sarnatherm 25 PSI
Minimum 1.4" thick
Any approved fastener
1:2 ft2
Minimum 2" thick
listed in Table 3
1:4 ft2
ISO 95+ GL
Minimum 1.4" thick or tapered
Any approved fastener
1:2 ft2
Minimum 2" thick or tapered
listed in Table 3
1:4 ft2
Approved High Density Wood Fiberboard
Minimum 1" thick
Any approved fastener
1:2 ft2
listed in Table 3
Note: All layers of insulation shall be mechanically attached using the fastener density listed
above. The insulation panels listed are minimum sizes and dimensions; if larger panels are used,
the number of fasteners shall be increased maintaining the same fastener density. Insulation
fasteners shall be tested for withdrawal resistance in compliance with Testing Application
Standard TAS 105 to confirm compliance with the wind load requirements. Please refer to Roofing
Application Standard RAS 117 for insulation attachment.
Membrane: G410 Felt adhered with Sarnacol 2170 applied at 1.25 gal./sq. to the substrate and
0.5 gal./sq. to the back of the Membrane, or Samacol 2121 applied to the
substrate only at 1.5 to 2.5 gal./sq.
Maximum Design
Pressure: -45 psf. (See General Limitation #9)
NOA No.: 13-0311.05
Expiration Date: 05/16/17
Approval Date: 07/18/13
Page 32 of 35
Membrane Type: PVC
Deck Type 7I: Recover, Insulated
Deck Description: Minimum 2500 psi concrete or concrete plank or min. 18-22 ga. steel
System Type C(2): All layers of insulation simultaneously fastened; membrane fully adhered.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
Base Insulation Layer: Insulation Fasteners Fastener
(Table 3) Density/ft2
Any Approved Polyisocyanurate Listed in Table 2
Minimum 1.51' thick N/A N/A
Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density.
Insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number
of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing
Application Standard RAS 117 for insulation attachment.
Top Insulation Layer: Insulation Fasteners Fastener
(Table 3) Density/ft2
DensDeck Prime
Minimum 5/8" thick 16 and 17 1:2
Note: Insulation panels listed are minimum sizes and dimensions; if larger panels are used, the
number of fasteners shall be increased maintaining the same fastener density. Please refer to
Roofing Application Standard RAS 117 for insulation attachment.
Membrane: G410 Felt adhered with Sarnaco12121 adhesive applied at a rate of 2.0 — 2.5
gal/sq. to substrate. Minimum 3" wide side lap is sealed with a 1.5" wide heat
weld.
Maximum Design
Pressures: -52.5 psf. (See General Limitation #7)
NOA No.: 13-0311.05
Expiration Date: 05/16/17
Approval Date: 07/18/13
Page 33 of 35
Membrane Type: PVC
Deck Type 7: Recover, Non -Insulated
Deck Description: Concrete/lightweight concrete/cementitious wood fiber/steel
System Type F: Membrane adhered to sustrate.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are
not approved and shall not be installed unless said accessories demonstrate compliance with
prescriptive Florida Building Code requirements and are field fabricated utilizing the approved
membranes listed in Table 1.
Fire Barrier: None
Membrane: G410 Felt adhered with Sarnacol 2170 applied to the substrate only at 1.5 to 2.5
gal/sq.
Maximum Design
Pressure: -45 psf. (See General Limitation #9)
NOA No.: 13-0311.05
Expiration Date: 05/16/17
Approval Date: 07/18/13
Page 34 of 35
RECOVER SYSTEM LIMITATIONS:
1. All System Limitations and General Limitations shall apply. See specific deck type Notice of
Acceptance for deck type System Limitations.
• GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials
Directory for fire ratings of this product.
2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with
Product Control Approval guidelines. All other layers shall be adhered in a full mopping of
approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically
attached using the fastening pattern of the top layer
3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved
asphalt, panel size shall be 4' x T maximum.
4. An overlay and/or recovery board insulation panel is required on all applications over closed cell
foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet
shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip
mopped 8" ribbons in three rows, one at each sidelap and one down the center of the sheet
allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break
shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either
system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited
to a maximum design pressure of -45 psf..
5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value
of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener
value, as field-tested, are below 275 lbf. insulation attachment shall not be acceptable.
6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based
on a minimum fastener resistance value in conjunction with the maximum design value listed
within a specific system. Should the fastener resistance be less than that required, as determined
by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida
Registered Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised
fastener spacing shall utilize the withdrawal resistance value taken from Testing Application
Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117.
7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these
areas. Fastener densities shall be increased for both insulation and base sheet as calculated in
compliance with Roofing Application Standard RAS 117 and/or RAS 137. Calculations prepared,
signed and sealed by a Florida registered Professional Engineer, Registered Architect, or
Registered Roof Consultant (When this limitation is specifically referred within this NOA,
General Limitation #9 will not be applicable.)
8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs
• shall conform with Roofing Application Standard RAS 111 and applicable wind load
requirements.
9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e.
field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for
enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners).
(When this limitation is specifically referred within this NOA, General Limitation #7 will not
be applicable.)
10. All products listed herein shall have a quality assurance audit in accordance with the Florida
Building Code and Rule 9N-3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE