HomeMy WebLinkAboutNOA Planks & PanelsMIAMI•DADE MIAMI-DADE COUNTY
MW PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy
James Hardie Building Product, Inc.
10901 Elm Avenue
Fontana, CA 92337
SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER-Product
Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction
(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein and has been designed to comply with the Florida Building Code,
including the High Velocity Hurricane Zone.
DESCRIPTION: "Hardie", "Cem" and "Prevail" Planks and Panels Fiber Cement Siding and Soffit
APPROVAL DOCUMENT: Drawing No. PNL, PLK & SOFF, titled "HardiePanel, CemPanel, Prevail
Panel; HardiePlank, CemPlank Prevail Lap Siding; HardieSoffit, CemSoffit Panel; Installation Details
Wood/Metal Stud Construction", sheets 1 through 12 of 12, dated 04/24/2013, prepared by the
manufacturer, signed and sealed by V. Andrew Tan, P.E. on 09/29/2020, bearing the Miami -Dade County
Product Control revision stamp with the Notice of Acceptance number and expiration date by the Miami -
Dade County Product Control Section.
MISSILE IMPACT RATING: Large and Small Missile Impact Resistant
LABELING: A permanent label with the manufacturer's name or logo, Plant City, Florida, and the
following statements: "ASTM C 1186 Type A compliant" and "Miami -Dade County Product Control
Approved" is to be located on each siding plank or panel and per FBC 1710.9.2 and 1710.9.3 on soffit
panels.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA # 17-0821.21 and consists of this page 1 and evidence pages E-1 and E-2, as well
as approval document mentioned above.
The submitted documentation was reviewed by Carlos M. Utrera, P.E.
NOA No. 20-0730.06
MIAMI•DADE COUNTY ,�� Expiration Date: May 1, 2022
22
Approval Date: November 12, 2020
Page 1
James Hardie Building Products, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
1. EVIDENCE SUBMITTED UNDER PREVIOUS NOAs
A. DRAWINGS "Submitted under NOA # 13-0311.07"
1. Drawing No. PNL, PLK & SOFF, titled "HardiePanel, CemPanel, Prevail Panel;
HardiePlank, CemPlank Prevail Lap Siding; HardieSoffit, CemSoffit Panel;
Installation Details Wood/Metal Stud Construction", sheets 1 through 12 of 12, dated
04/24/2013, prepared by the manufacturer, signed and sealed by Ronald 1. Ogawa,
P.E.
B. TESTS "Submitted under NOA # 13-0311.07"
1. Test reports on 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
2) Cyclic Wind Pressure Loading per FBC, TAS 203-94
along with marked -up drawings and installation diagram of HardiePlank, HardieSoffit
and HardiePanel, prepared by Intertek Testing Services NA LTD, Test Report No.
100733361COQ-004, dated 08/24/2012, with revision 1 dated 04/25/2013, signed and
sealed by Rick Curkeet, P.E.
"Submitted under NOA # 02-0729.02"
Laboratory Report Test Date Signature
2. ATI-16423-1 PA 202 & 203 03/18/96 A. N. Reeves P.E.
3. ATI 16423-2 PA 202 & 203 03/18/96 A. N. Reeves P.E.
4. ATI 16423-3 PA 202 & 203 03/18/96 A. N. Reeves P.E.
C. CALCULATIONS
1. None.
D. QUALITY ASSURANCE
1. Miami -Dade Department of Regulatory and Economic Resources (RER)
E. MATERIAL CERTIFICATIONS
1. None.
F. STATEMENTS "Submitted under NOA # 15-0122.04"
1. Statement letter of code conformance to the 5t' edition (2014) FBC issued by Ronald
I. Ogawa & Associates, Inc., dated 10/26/2014, signed and sealed by Ronald I.
Ogawa, P.E.
Carlos M. Utrera, P.E.
Product Control Examiner
NOA No. 20-0730.06
Expiration Date: May 1, 2022
Approval Date: November 12, 2020
E-1
James Hardie Building Products, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
2. NEW EVIDENCE SUBMITTED
A. DRAWINGS
1. Drawing No. PNL, PLK & SOFF, titled "HardiePanel, CemPanel, Prevail Panel;
HardiePlank, CemPlank Prevail Lap Siding; HardieSoffit, CemSoffit Panel; Installation
Details Wood/Metal Stud Construction", sheets 1 through 12 of 12, dated 04/24/2013,
prepared by the manufacturer, signed and sealed by V: Andrew Tan, P.E. on 09/29/2020.
B. TESTS
1. None.
C. CALCULATIONS
1. None.
D. QUALITY ASSURANCE
1. Miami -Dade Department of Regulatory and Economic Resources (RER)
E. MATERIAL CERTIFICATIONS
1. None.
F. STATEMENTS
1. Statement letter of code conformance to the 7th Edition (2020) of the FBC and of no
financial interest issued by Construction Applied Engineering, dated 07/22/2020,
signed and sealed by V. Andrew Tan, P.E.
"Submitted under NOA # 17-0821.21"
2. Statement letter of code conformance to the 6th Edition (2017) FBC and of no financial
interest issued by Ronald I. Ogawa & Associates, Inc., dated 07/30/2017, signed and
sealed by Ronald I. Ogawa, P.E.
Carlos M. Utrera, P.E.
• Product Control Examiner
NOA No. 20-0730.06
Expiration Date: May 1, 2022
Approval Date: November 12, 2020
E-2
WALL LENGTH
SEE
Stud Sparing at 16" O.C. Ha dePanelO, Cempanleell®, &
Bt i I I DETAIL A Prevail® Panel Siding materials are
—'---=•- `-•-••-t---••c•;--•°.•- - ---....- ��. 5!8" APA rated
nonasbestosfiber-cement produ s
i ' ' , thick / 5 p ra
products
i i ; tested in accordance with ASTM
plywood sheathing in C1186 Grade II, Type A and meeting
accordance with Florida the requirements of the Florida
aaRwmplvan with tho Florida ���\\ : C.'��OE N 3 ` �i 2322.3Building Code Section Building Code.
aundinaptta a .� _ ;
woa No 20-0730.06 Z ! '
WALL 3�0, 81 _ A�NEL DIME SN IONS
Expiration DatoOS/0112022 i / 'ti _ water -resistive Width Length Thickness
(EIGHTT By _ barrier per Florida 4' 8,9,1U 5/16"
Miami -Da o Product ControllL! i' Building Code
=;' SIATE05:
Li ` �� Section 1404.2 DESIGN PRESSURE RATING
i• FCORM v Installation Design Pressure
Wood Stud 7
W d Studs oo s pf
►I HardiePanel, Impact Resistant—
B l--=
Nails at 16" O.C. (typ.) SECTION B-B Compare], Planks installed over 5/8" thick / 5 ply
3/8.. Minimum Edge Distance Prevail Panel APA rated plywood sheathing
Siding
DETAIL A
i
i\
Sheathing fastener, as described in
Note 1
Panel fastener, as described in
Note 2
i HardiePanel, Cempanel,
Prevail Panel Siding
I
Water -resistive barrier per
- Florida Building Code Section
\ ♦ �/ 1404.2
` 5/8" thick / 5 ply APA rated
plywood sheathing fastened in
accordance with Florida Building
Code Section 2322.3
2" X 4" S-P-F Wood Studs
The wall and soffit frames are to be designed
by the Architect or Engineer of Record in
compliance with the Florida Building Code.
HARDIEPANEL. CEMPANEL, PREVAIL PANEL SIDING INSTALLATION DETAILS
• All installation shall be done in conformance with this Notice of Acceptance, the manufacturer's
installation recommendations, and the applicable sections of the Florida Building Code.
• Wood studs where HardiePanel, Cempanel, Prevail Panel Siding will be installed shall be
designed by an Engineer or Architect per the Florida Building Code and the requirements of this
N.O.A.
• [Note 1 [ 518" thick / 5 ply APA rated plywood sheathing shall be attached to the studs in
accordance with Florida Building Code Section 2322.3.
• The siding panels shall be installed over 5/8" thick / 5 ply APA rated plywood sheathing supported
by a minimum of 2"X4" S-P-F wood studs spaced a maximum of 16" O.C.
• [Note 21 The siding panel fastener shall be a 2' long, 0.223" head diameter, 0.092" shank
diameter, corrosion resistant siding nail; the fasteners shall be spaced at 6" O.C. at panel edges
and intermediate studs; the fasteners shall be driven through the 5/8" thick / 5 ply APA rated
plywood sheathing Into wood studs located at 16" O.C.
• Fasteners shall have a minimum edge distance of 3/8" and a minimum clearance of 2" from
comers.
HARDIEPANEL, CEMPANEL, PREVAIL PANEL
INSTALLATION DETAILS WOOD STUD CONSTRUCTION
James Hardie Building Products, Inc.
10901,E1m Avenue
Fontana, CA 92337
i2F FSCM NO I Dwa NO
A PNL-PLKSOFF
Creator: E. Gonzales IsruE 112"=1'-0" I Date: 9292020 1SHEET
1 OF 12
REV
Fastener Spacing per Florida (� Cladding
Building Code Section 2322.3 I16.00in.
�.
I• � i Framing
i
• Fastener Spacing per Florida j Sheathing
Building Code Section 2322.3
i
�����,�•g.E��T���i PRODUCT REVISED ,f
as complying with the Florida
(121.'. i Building Code y9,/
No. 20-0730.06
i-Xn NOA-�o. 81662 Expiration Date 05/01 /2022
'4�`(,r*� OI • Mlaml-DadProduct Control
J t�
1
FRAMING
• NOMINAL 2" X 4" S-P-F WOOD STUDS 16" O.C. FASTENED
WITH 3-112' 16d COMMON NAILS (2 PER TOP AND
FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE
BOTTOM CONNECTION)
NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS)
• THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED
BY THE ARCHITECT OR ENGINEER OF RECORD IN
COMPLIANCE WITH THE FLORIDA BUILDING CODE
S11EAIUM
• NOMINAL 5/8" THICK / 5 PLY APA RATED PLYWOOD
HARDIEPANEL, CEMPANEL, PREVAIL PANEL
SHEATHING FASTENED IN ACCORDANCE WITH FLORIDA
INSTALLATION DETAILS WOOD STUD CONSTRUCTION
BUILDNG CODE SECTION 2322.3
CLADDING
pig
• THE PANEL IS FASTENED WITH 2' LONG, 0.223" HEAD
James Hardie Building Products, Inc.
DIAMETER, 0.092' SHANK DIAMETER, CORROSION
10901 Elm Avenue
RESISTANT SIDING NAILS, PLACE NAILS 6" O.C. AT
Fontana, CA 92337
PANEL EDGES AND INTERMEDIATE STUDS
Phone: 909-356-6300
SIZE
FSCM NO
DYM No
REV
•
Fax 909-427-0634
A
PNL-PLKSOFF
2
Creator. E. Gonzales
ScaLF 1"=1'.0"
Date:9/29/2020 SHEET 2OF 12
WALL LENGTH
Stud Spacing at 16" O.C.
�.._.:_...._.., :_.. _ .... :... \`;ant' + •'% t .
I PRODUCT REVISED �t�.G %CEN3.Lrq X�
as complying with the Florida ,4 i
Building Codo
HOA-No. 2G-0730.06 _ ' ��PNo: 8161i�.
I I 11
WALL : Expiration Date 05/01/2022
IEIGHT By
hHami-0ado Product Control;+'. ;,.:STATE OF
,i , '�� �
��i�'� t+ cCOR10 - � \
i ��1'/11111111Y'It�
i ..
1
3/8" Minimum Edge Distance Nails at 6" O.C. (typ.)
SEE
PRODUCT DESCRIPTION
DETAIL A
HardiePanel®, Cempanel®, & Prevail®
Panel Siding materials are nonasbestos
518" thick / 5 ply APA rated
fiber -cement products tested in
(
`
plywood sheathing fastened
accordance with ASTM C1186 Grade II,
to metal studs as described
Type A and meeting the requirements of
In Note 1
the Florida Building Code.
i
j
Water -resistive
PANEL DIMENSIONS
Width Length Thickness
barrier per Florida
4' 8,9,10' 5/16"
Building Code
Section 1404.2
DESIGN PRESSURE RATING
Installation Design Pressure
toga, 3-518" x 1-5/8"
Metal Studs -104 psf
Metal C-stud
(
HardiePanel,
Impact Resistant -
SECZON B-B
Cempanel,
Panel installed over 5/8" thick / 5 ply
Prevail Panel
APA rated plywood sheathing
Siding
HARDIEPANEL. CEMPANEL. PREVAIL PANEL SIDING INSSALLATION DETAILS
" All Installation shall be done in conformance with this Notice of Acceptance, the manufacturer's
Installation recommendations, and the applicable sections of the Florida Building Code.
" Metal studs where HardiePanel, Cempanel, Prevail Panel Siding will be Installed shall be
Sheathing fastener, as
designed by an Engineer or Architect per the Florida Building Code and the requirements of this
described in Note 1
N.O.A.
■ [Note 1] 5/8" thick / 5 ply APA rated plywood sheathing shall be attached to metal studs at 6"oc
Panel fastener, as described in
at panel edges and all intermediate supports using a No.8-18, 0.315" head diameter x 1-1/4" long
Note 2
bugle head screw
The siding panels shall be installed over 5/8" thick / 5 ply APA rated plywood sheathing
supported by a minimum 20ga, Nominal 3-5/8" X 1-518" Metal C-studs spaced a maximum of 16"
O.C.
— HardiePanel® Siding
" [Note 21 The siding panel fastener shall be a minimum No. 8-18, 0.315" head diameter X 1-5/8"
long' ribbed bugle head screw ("or screw shall have at least 3 full threads penetrating metal
framing); the fasteners shall be spaced at 6" O.C. at panel edges and intermediate studs; the i
Water -resistive barrier. per
fasteners shall be driven through the 5/8" thick / 5 ply APA rated plywood sheathing into metal f
- Florida Building Code Section
studs located at 16" O.C.
" Fasteners shall have a minimum edge distance of 3/8" and a minimum clearance of 2" from
1404.2
comers.
--- 5/8" thick / 5 ply APA rated
L plywood sheathing fastened
to metal studs as described
In Note 1.
20ga, 3-5/8" X 1-5/8" Metal C-stud
The wall and soffit frames are to be designed
by the Architect or Engineer of Record in
compliance with the Florida Building Code.
ig
HARDIEPANEL, CEMPANEL, PREVAIL PANEL
INSTALLATION DETAILS METAL STUD CONSTRUCTION
James Hardie Building Products, Inc.
10901 Elm Avenue
Fontana, CA 92337
Phone: 909-356-6300 StzE FSCM NO DWG NO REV
Fax 909.427.0634 A PNL-PLKSOFF 2
Creator: E. Gonzales SCALE 112" =1'-0' 1 Date: 929/2020 SHEET 3 OF 12
6.00in. I 6.00 Cladding
1in.-------*�
I�__.. _........ ... _ _.L. __._...._............. _.......... -.. ..............
6.00in.
} Framing
6.00in. i Sheathing
i
6.00In.
PRODUCT REVISED
as ilding complying with the Florida '
BuCoda
NOA No. 20-0730.06 \ 1 I i 1 ! •` j //
Expiration Date 05/O7/2022 , - \\\\\�1?! E'
Y �• r i
Miami -Dade Product ControlZIL��LI •
o. 81662 is
FLORN P" C�••���
NN MGNAL 20 GAUGE 3-5/8" X 1-518" STEEL STUDS 16" O.C. ///l�//j /111 I� 1 ' �'q!7 f � 0
FASTENED WITH 5/8' WAFER HEAD SCREWS (2 PER TOP 9j ';
AND BOTTOM CONNECTION)
• THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE
BY THE ARCHITECT OR ENGINEER OF RECORD IN NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS)
COMPLIANCE WITH THE FLORIDA BUILDING CODE
SHEATHING
• NOMINAL 5/8" THICK 15 PLY APA RATED PLYWOOD
SHEATHING TO METAL STUDS AT 6" OC AT PANEL
EDGES AND ALL INTERMEDIATE SUPPORTS USING A HARDIEPANEL, CEMPANEL, PREVAIL PANEL
HEAD , 0.315"HEAD DIAMETER X 1-1/4° LONG BUGLEgig
INSTALLATION• DETAILS METAL STUD CONSTRUCTION
HEAD STHE PANEL IS FASTENED WITH NO. 8-18,0.315" HEAD James Hardie Building Products, Inc.
DIAMETER X 1-5/8"LONG CORROSION RESISTANT 10901 Elm Avenue
RIBBED BUGLE HEAD SCREWS (SCREW SHALL HAVE AT Fontana, CA 92337
LEAST 3 FULL THREADS PENETRATING THE METAL Phone: 909-356.6300 S¢E FSCM NO G NO REv
FRAMING), PLACE SCREWS 6" O.C. AT PANEL EDGES Fax 909 427-0634 A LK-SOFF 2
AND INTERMEDIATE STUDS
Creator: E. Gonzales SCALE V =1' 0" Dat�9/291�202EET 4 OF 12
Stud Spacing et 16" O.C. WALL LENGTH
--
B t- ih--IL--►I�
-T_
--
--
t
r
PRODUCTgREVISED
I
aulldin pl� gewith the Rorlda
a
.l
�`•:
=1 i ;-,
VALL
TIGHT
i
Nop tto. 20-0730.06
expiration Date05/0112022
1662
X t4 y i k
f� / --
tgaf%ytiE
j
By
0 !�
Miami: Dade Product Control
;
FLpRtO CGS
„
„
,. 1
B 4-- !r-
3/4" Minimum Edge Distance Nails at 16" O.C. (typ.)
DETAILA
i..
r
i
I
SEE l?_R0AUC1 AESCEiIPJJO.y
DETAIL A HardiePlank®, Cemplank®, &
—T\ Prevail® Plank Lap Siding materials
5/8" thick / 5 ply APA are nonasbestos fiber -cement
lrated plywood products tested in accordance with
l sheathing in ASTM C1186 Grade II, Type A and
accordance with meeting the requirements of the
Florida Building Code Florida Building -Code.
Section 2322.3
Water -resistive Width.l DLength 0NS
Width Length Thickness
barrier per Florida 59-1/2" 12' 5/16"
Building Code
Section 1404.2 DESIGN PRESSURE RATING
2" X 4" S-P-F Installation Design Pressure
- Wood Studs Wood Studs -92 psf
Lap Siding Impact Resistant -
SECTIOPlanks installed over 5/8" thick / 5 ply
_.
g-g 1-1/4" tall X 5/15" APA rated plywood sheathing
thick starter strip
_ Sheathing fastener, as
HARDIEPLANK CEMPLANK PREVAIL LAP SIDING INSALLAAIION DEJQILS
described in Note 1
All installation shall be done in conformance with this Nofice of Acceptance, the manufacturer's
Installation recommendations, and the applicable sections of the Florida Building Code.
Wood studs where. HardiePlank, Cemplank, Prevail Lap Siding will be installed shall be designed by an
Engineer or Architect per the Florida Building Code and the requirements of this N.O.A.
\ Siding fastener, as
" [Note 11518" thick / 5 ply APA rated plywood sheathing shall be attached to the studs in accordance
described In Note 2
with Florida Building Code Section 2322.3.
\
Planks shall be applied horizontally commencing from the bottom course of the wall with 1-1/4" wide
laps at the top of the plank such that the exposure area of each plank is s 8-114" vertically.
1 HardiePlank,
• [Note 21 The siding fastener shall be a 2-1/2" long, 0.223" head diameter. 0.092" shank diameter,
Cemplank, Prevail
corrosion -resistant siding nail; The siding is fastened:5 B-1/4" O.C. vertically and 16" O.C. horizontally;
Lap Siding
fasteners are driven Into wood studs through 5/8" thick / 5 ply APA rated plywood sheathing, fasteners
are placed in the overlapping area approximately 3/4" from the bottom edge of the overlapping plank.
Vertical joints shall be placed over studs.
/ Water -resistive barrier
The planks shall be installed over 518" thick / 5 ply APA rated plywood sheathing supported by a
��— per Florida Building
minimum of 2"X4" S-P-F wood studs spaced a maximum of 16" O.C.
j Code Section 1404.2
Fasteners shall have a minimum edge distance of 3/8".
j
5/8" thick / 5 ply APA rated
HARDIEPLANK, CEMPLANK, PREVAIL LAP SIDING
plywood sheathing fastened
INSTALLATION DETAILS WOOD STUD CONSTRUCTION
in accordance with Florida
99W
Building Code Section
James Hardie Building Products, Inc.
-Avenue
2322.3
10901 Elm
Fontana, CA 92337
2" X 4" S-P-F Wood Studs
The wall and soffit frames are to be designed
Fax 909 427-0634
by the Architect or Engineer of Record in
compliance with the Florida Building Code. Creator: E. Gonzales
owe NO
PNL-PLK-SOFF
1/2"= 1'-0" ' Date: 9/29/2020
5OF12
PEv
Fastener Spacing per Florida I i
Building Code Section 2322.3 + 16 in. O Cladding
• Framing
-- __ _ Fastener Spacing per Florida I Sheathing
Building Code Section 2322.3 j
1
- 0.75in =---------------------.---....,
T ......•••. � •.
r PRODUCT REVISED
as camp lying with the Florida
Building
Coodd
.--------------- --•NBA-No. 20-0730.06---•---•- :---.._....................... .
Expiration DatoOS101/2022
By
f?flm=
Mlam{-Dodo Product Control . . �� •, t—a-
------ . f;Zl i
58.251n. ? o62
• —SSA?EF ,
�RA.MI.M9G //Or�l►}���\t12�jzo
i NOMINAL 2" X 4" S•P-F WOOD STUDS 16" O.C. FASTENED
WITH 3-112° 16d COMMON NAILS (2 PER TOP AND
BOTTOM CONNECTION) FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE
I THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS)
BY THE ARCHITECT OR ENGINEER OF RECORD IN
iCOMPLIANCE WITH THE FLORIDA BUILDING CODE
$HEATHWO
( NOMINAL 5/8" THICK / 5 PLY APA RATED PLYWOOD
SHEATHING FASTENED IN ACCORDANCE WITH FLORIDA HARDIEPLANK, CEMPLANK, PREVAIL LAP SIDING
I BUILDING CODE SECTION 2322.3
CLAQ_0jN,Q INSTALLATION DETAILS WOOD STUD CONSTRUCTION
PLANKS OVERLAP 1-1/4°
• THE EXPOSURE IS 58-1/4" James Hardie Building Products, Inc.
• THE PLANKS ARE FACE NAILED WITH 2-1/2° LONG, 0.223" 10901 Elm Avenue
HEAD DIAMETER, 0.092" SHANK DIAMETER, CORROSION- • ' Fontana, CA 92337
RESISTANT SIDING NAILS, PLACED 3/4" UP FROM THE Phone: 909-356-6300 S11E FSCM NO DWGNO REV
BOTTOM EDGE OF THE PLANK AT EACH STUD LOCATION Fax 909-427-0634 A PNL-PLK-SOFF 2
Creator. E. Gonzales SCALE 1" =1'-0" Data: 9129/2020 ... 6 OF 12
Dl= TAIL A
Sheathing fastener, as
described in Note 1
Siding fastener, as
/- II described In Note 2
y(f / HardiePlank,
Cemplank,
Prevail Lap Siding
Water -resistive
\� barrier per Florida
Building Code
-` Section 1404.2
5/8" thick / 5 ply APA rated
_ plywood sheathing fastened to
metal studs as described in
Note 1
20ga, 3-5/8" X 1-518" Metal C-stud
The wall and soffit frames are to be designed
by the Architect or Engineer of Record in
compliance with the Florida Building Code.
SEE
DETAIL
l?RPQ- CT DE.%CR1E ON.
A HardiePlank®, Cemplank®, and
-�� 5/6" thick ply APA Prevail® Plank Lap Siding materials
1 rated plywood are nonasbestos fiber -cement
r
t
sheathing fastened products tested in accordance with
ASTM C1186 Grade II, Type A and
to metal studs
meeting the requirements of the
described in Note 1
Florida Building Code.
Water -resistive
barrier per Florida LANK DIMENSIOLIS
Building Code Width Length Thickness
Section 1404.2 5 9-1/2" 12' 5116"
20ga, 3-5/8" X 1-5/8" DESIGN PRESSURE RATING
R\ Metal C-stud Installation Design Pressure
\HardiePlank Metal Studs -92 psf
Cemplank, Prevail
SECTION
Lap Siding Impact Resistant -
B=g \ 1-1/4" tall X 5/16" Planks installed over 5/8" thick / 5 ply
thick starter strip APA rated plywood sheathing
HARDIEPLANK. CEMPLANK. PREVAIL LAP SIDING INSTALLATION DETAILS
• All installation shall be done in conformance with this Notice of Acceptance, the manufacturer's installation
recommendations, and the applicable sections of the Florida Building Code.
• Metal studs where HardiePlank, Cemplank, Prevail Lap Siding will be installed shall be designed by an
Engineer or Architect per the Florida Building Code and the requirements of this N.O.A.
• [Note 1] 5/8" thick / 5 ply APA rated plywood sheathing shall be attached to metal studs at 6"oc at panel
edges and all intermediate supports using a No.8-18, 0.315" head diameter 1-1/4" long bugle head screw
• Planks shall be applied horizontally commencing from the bottom course of the wall with 1-1/4" wide laps at
the top of the plank such that the exposure area of each plank is s 8-1/4" vertically.
• [Note 2] The siding fastener shall be a minimum No. 8-18, 0.315" head diameter X 2-1/4" long` bugle head
screw over metal studs eor screw shall have at least 3 full threads penetrating metal framing); The siding is
fastened:5 B-1/4" O.C. vertically and 16" O.C. horizontally; fasteners are driven into metal studs through 518"
thick / 5 ply APA rated plywood sheathing, fasteners are placed in the overlapping area approximately 314"
from the bottom edge of the overlapping plank.
• Vertical joints shall be placed over studs.
• The planks shall be installed over 5/8" thick / 5 ply APA rated plywood sheathing supported by a minimum
20ga, Nominal 3-5/8" X 1-5/8" Metal C-studs spaced a maximum of 16" O.C.
• Fasteners shall have a minimum edge distance of 3/8".
HARDIEPLANK, CEMPLANK, PREVAIL LAP SIDING
INSTALLATION DETAILS METAL STUD CONSTRUCTION
James Hardie Building Products, Inc.
10901 Elm Avenue
Fontana, CA 92337
PNL-PLK-SOFF
Creator: E. Gonzales ISCALE 1/2" = 1'-0" I Data: mg/2020 (SHEET 7 OF 12
. 6.00in.
PRODUCT REVISED
as wmpiying with the Florida
Building Code
NOA-No. 20-0730.06 .......
ExpirationnyDate05/01/2022 By
Mlaml-Dade Product Control
-------------- T.............................
,
58.2
•
FRAMING
NOMINAL 20 GAUGE 3-5/8" X 1-5/8" STEEL STUDS 16"
O.C. FASTENED WITH 5/8" LONG RIBBED BUGLE HEAD
SCREWS (2 PER TOP AND BOTTOM CONNECTION)
THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED
BY THE ARCHITECT OR ENGINEER OF RECORD IN
COMPLIANCE WITH THE FLORIDA BUILDING CODE
SHEAThING
• NOMINAL 5/8" THICK / 5 PLY APA RATED PLYWOOD
SHEATHING TO METAL STUDS AT 6" OC AT PANEL
EDGES AND ALL INTERMEDIATE SUPPORTS USING A
NO.8-18, 0.315" HEAD DIAMETER X 1-1/4" LONG BUGLE
HEAD SCREW
� _C.„IADDINCa,
f PLANKS OVERLAP 1-1/4"
' THE EXPOSURE IS s 8-1/4"
THE PLANKS ARE FASTENED WITH NO. 8-18,0.315"
HEAD DIAMETER X 2-1/4" LONG CORROSION -
RESISTANT RIBBED BUGLE HEAD SCREWS (SCREW
SHALL HAVE AT LEAST 3 FULL THREADS
PENETRATING THE METAL FRAMING), PLACED 3/4• UP
FROM THE BOTTOM EDGE OF THE PLANK AT EACH
STUD LOCATION
Cladding
Framing
l
Sheathing
0\\7 1,1 111111,
------------------------ .............. -
���\ ` USN �••�9�/�/
/ `Nb
1. 1662
ex�-ll-
41�
�j CCU•• �ORIOP.•G\'?\\�
FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRA�ITY LOAD ARE
NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS)
HARDIEPLANK, CEMPLANK, PREVAIL LAP SIDING
INSTALLATION DETAILS METAL STUD CONSTRUCTION
James Hardie Building Products, Inc.
10901 Elm Avenue
Fontana, CA 92337
Phone: 909-356.6300
SIZE FSCM NO DWG NO RtV
Fax 909-427-0634 A PNL-PLK-SOFF 2
Creator. E. Gonzales SCALE 1" 1'•0" I Date: 9/29/2020 1 SNEET 8 OF 12
i WALL LENGTH SEE
Stud Spacing at 16" O.C. DETAIL A
j1 i PRODUCT REVISED i
I ; i as comp)yIng with the Florida
I Buitdina Coda 2" X 4" S P F
Non -No. 20-0730.06 :i. Wood Studs
WALL i
IEIG i Expiration Date6S/01/2022
1 I 6
i Y
i
Miam Dade Product Control HardieSoffit,
:+ ►"' Cemsoffit
SECTION B-B
Nails at 4" O.C. (typ.)
318" Minimum Edge Distance
DETAIL
0
offit fastener, as
ascribed in Note 1
HardieSofli Cemsoffit
L
Minimum 2" X 4" S-P-F Wood Studs
The wall and soffit frames are to be
designed by the Architect or
Engineer of Record in compliance
_
with the Florida Building Code. -
PRODUCT DESCRIPTION
HardieSoffit® & Cemsoffit® materials are
nonasbestos fiber -cement products tested in
accordance with ASTM C1186 Grade it, Type A
and meeting the requirements of the Florida
Building Code.
Width Length Thickness
4' 8' 114"
MI.GN.PRESSURE RATING.
Installation Design Pressure
Wood Studs -70 psf
`��,14IiI11JJ
WOO
��V •l.�rr5l r,l, i
HARDIESOFFIT, CEMSOFFIT PANEL INSTALLATION- DETAILS
• All installation shall be done in conformance with this Notice of Acceptance, the manufacturer's
installation recommendations, and the applicable sections of the Florida Building Code.
• Wood studs where HardleSoffd, Cemsoffit will be installed shall be designed by an Engineer or
Architect per the Florida Building Code and the requirements of this N.O.A.
• The soffit shall be installed over minimum 2"X4" S-P-F wood studs spaced a maximum of 16" O.C.
• [Note 1] The soffit fastener shall be a 2" long, 0.223" head diameter, 0.092" shank.diameter,
corrosion resistant siding nail; the fasteners shall be spaced at 4" O.C. at panel edges and
intermediate studs; the fasteners shall be driven into wood studs located at 16" O.C.
• Fasteners shall have a minimum edge distance of 3/8" and a minimum clearance of 2" from comers.
HARDIESOFFIT, CEMSOFFIT PANEL
INSTALLATION DETAILS WOOD STUD CONSTRUCTION
James Hardie Building Products, Inc.
10901 Elm Avenue
Fontana, CA 92337
Fax 909-427-0634 A I PNL-PLK-SOFF
Creator: E. Gonzales SCALE 12" =1'-0" I Date: 929/2020 SHEET
9OF12
REV
2
Cladding
Framing
4.00in.1
PRODUCTREVISED
I �\\IIIIII�S/��/
• �. .
sRcamplyCIng
'
`%
Building Code
n"A-No. 20-0730.06
��
F•;-•-- -•!q�//
�,
•
Expiration ante0S101/2022By
X� i
• Mlam ade product ConVo
ZZ
;41j
•
%
STATE OF ZZ
'•FCOR10-
/ON 0'1
;.
�. Q aC
F-RAMING
NOMINAL 2" X 4" S-P-F WOOD STUDS 16" O.C. FASTENED
WITH 3-1/2" 16d COMMON NAILS (2 PER TOP AND BOTTOM
CONNECTION)
THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED BY
THE ARCHITECT OR ENGINEER OF RECORD IN COMPLIANCE
WITH THE FLORIDA BUILDING CODE
CL.&DM
THE SOFFIT IS FASTENED WITH 2" LONG, 0.223" HEAD
DIAMETER, 0.092" SHANK DIAMETER, CORROSION
RESISTANT SIDING NAILS, PLACE NAILS V O.C. AT PANEL
EDGES AND INTERMEDIATE STUDS
FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE
NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS)
HARDIESOFFIT, CEMSOFFIT PANEL
INSTALLATION DETAILS WOOD STUD CONSTRUCTION
James Hardie Building Products, Inc.
u , 10901 Elm Avenue
Fontana, CA 92337
Phone:909-356-6300 SIZE FSCMNO owoNO RE
Fax 909-427 0634 A PNL-PLK SOFF 2
Creator: E. Gonzales SCALE 1" = V-0" Date: 929/2020 SHEEr 10 OF 12
?
WALL LENGTH-
Stud Spacingl at 16I" O.C.
Bf -i ��—►i
•;
i , .
I.1
-
PRODUCT REVISED
i
I
as co ryinColo vAlh the Flo Ada
I auading
NOA-No. 20-0730.06
WALL
ExplmdonDate 05/01/2022 Ii
HEIGHT
II By
•1
I MI a e Pmduct "ntroi
•
i
B
< = i1
I Nails at 6" O.C. (typ.)
318" Minimum Edge Distance
DETAIL A
t fastener, as
ribed in Note 1
HardieSoffit, Cemsoffit
[20ga, 3-5/8"X 1-5/8" Metal C-stud
he wall and soffit frames are to be
esigned by the Architect or Engineer
of Record in compliance with the
Florida Building Code.
SEE
PRODUCT DESCRIPTION
DETAIL A
HardieSoffil® 8 Cemsoffit® materials
are nonasbestos fiber -cement products
tested in accordance with ASTM C1186
l
Grade II, Type A and meeting the
requirements of the Florida Building
Code.
20ga, 3-5/8" X 1-518"
SOFFIT DIMENSIONS
Metal C-stud
Width Length Thickness
4' 8' W
HardieSofft,
Cemsotfit
DESIGN PRESSURE RATING
Installation fl@ i J! Pressure
S=S��S`f///
Metal StudA
SECTION B-B
exP• z12S"? 7•I •, I
No. 81662
STATE OF
/x°C OR4OP�����
NA11E\\,�
HARDIESOFFIT. CEMSOFFIT PANEL INSTALLATION DETAILS
• All installation shall be done in conformance with this Notice of Acceptance, the manufacturers
installation recommendations, and the applicable sections of the Florida Building Code.
• Metal studs where HardieSoffrt, Cemsoffit will be installed shall be designed by an Engineer or
Architect per the Florida Building Code and the requirements of this N.O.A.
• The soffit shall be installed over minimum 20ga, Nominal 3-5/8" X 1-518" Metal C-studs spaced
a maximum of 16" O.C.
• [Note 1] The soffit fastener shall be a minimum No. 8-18, 0.315" head diameter X 1-1/4" long`
ribbed bugle head screw (*or screw shall have at least 3 full threads penetrating metal
framing);the fasteners shall be spaced at 6" O.C. at panel edges and intermediate studs; the
fasteners shall be driven into metal studs located at 16" O.C.
• Fasteners shall have a minimum edge distance of 3/8" and a minimum clearance of 2" from
comers.
HARDIESOFFIT, CEMSOFFIT PANEL
INSTALLATION DETAILS METAL STUD CONSTRUCTION
James Hardie Building Products, Inc.
10901 Elm Avenue
Fontana, CA 92337
Phone:909-356-6300 SIZE FSCMNO DVVGNO RED
Fax 909-427-0634 A PNL-PLK-SOFF 2
Creator: E. Gonzales SCALP 1/2'= 1'-V' I Date: 9/29/2020 SHEET 11 OF 12
6.001n.—+I F— 16.001n.---►f
, _.................... -- ........... _.T Cladding
{
• i ; Framing
t
T 3
6.00in. 1
PRODUCT REVISED
ascomp with the Florida
Building Code
• NOA-No. 20-0730.06
Expiration DateOS/01/2022
By di--
��1lUlU/!1
lifarnPb= Product Contro
I1. i
�N0.8166. x -
-o nF
kr`
CORtO�
omlA j
• NOMINAL 20 GAUGE 3-518" X 1-5/8" STEEL STUDS 16" O.C.
FASTENED WITH 5/8" WAFER HEAD SCREWS (2 PER TOP FOR METAL AND WOOD STUDS, PROVISIONS FOR DIAPHRAGM ACTION AND GRAVITY LOAD ARE
AND BOTTOM CONNECTION) NOT PART OF THIS APPROVAL (MUST PROVIDE ALTERNATE PROVISIONS FOR THESE LOADS)
• THE WALL AND SOFFIT FRAMES ARE TO BE DESIGNED
BY THE ARCHITECT OR ENGINEER OF RECORD IN
COMPLIANCE WITH THE FLORIDA BUILDING CODE
CLADDING HARDIESOFFIT, CEMSOFFIT PANEL
THE SOFFIT IS FASTENED WITH NO. 8•18, 0.315" HEAD
DIAMETER X 1-1/4 " LONG CORROSION RESISTANT RIBBED INSTALLATION DETAILS METAL STUD CONSTRUCTION
BUGLE HEAD SCREWS (SCREW SHALL HAVE AT LEAST 3
FULL THREADS PENETRATING THE METAL FRAMING), PLACE James Hardie Building Products, Inc.
SCREWS 6" O.C. AT PANEL EDGES AND INTERMEDIATE 10901 Elm Avenue
STUDS ' Fontana, CA 92337
Phone:909-356-6300 s¢E FSCMNO DWDNo REV
Fax 909-427-0634 A PNL-PLK-SOFF 9
Creator. E. Gonzales SCALE V = T-0" Date: 9/20/2020 SHEET 12 OF 12