HomeMy WebLinkAboutNOA ply Roofing Over Wood Deck�MIAMI-QADE MIAMI-DADE COUNTY PRODUCT CONTROL SECTION - 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy Sika Sarnafil, A Division of Sika Corp. 100 Dan Road Canton, *A 02021 '$COPE: Xi his NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply, with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Sika Sarnafil PVC Single Ply Roofing over Wood Deck LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the ,*xplratun date may be displaye&in.advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. fNSPECTION: A copy of this entire NOA, shall: be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the, request of the Building Official. 16� is NOA renews NOA No. 19-0513.03 and consists ofpag�es,1 through 12. Tha,submitted documentation was reviewed by Alex Tigera. NOA No.: 20-0825.09 Expiration Date: 08/02/26 Approval Date: 03/04/21 Page 1 of 12 ROOFING SYSTEM APPROVAL Category: Roofing Sub -Category: Single Ply Material: PVC Deck Type: Wood Maximum Design Pressure: -75 psf TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description G410 48, 60, 72 and 80 ASTM D4434 Fiberglass reinforced PVC roofing membrane. mils G410 Textured 48, 60, 72 and 80 ASTM D4434 Fiberglass reinforced PVC roofing membrane. mils S327 48, 60, 72 and 80 ASTM D4434 Polyester reinforced PVC roofing membrane. mils S327 Textured 48, 60, 72 and 80 ASTM D4434 Polyester reinforced PVC roofing membrane. mils S327 (10 ft) 48, 60, 72 and 80 ASTM D4434 Polyester reinforced PVC roofing membrane. mils S327 Felt 48, 60, 72 and 80 ASTM D4434 Polyester reinforced PVC roofing membrane. mils Sikaplan Fastened 45 mils or 60 mils ASTM D4434 White polyester reinforced PVC roofing membrane. Sikaplan Fastened Feltback 45 mils or 60 mils ASTM D4434 White polyester reinforced PVC roofing membrane. Sikaplan Adhered 60 mils ASTM D4434 White polyester reinforced PVC roofing membrane. Sarnacol 2170 VC Various Proprietary Solvent -based, VOC compliant adhesive. Sarnatred 3.25' x 32.8' Proprietary PVC walkway protection sheet. Sarnaclad Various Proprietary Heat weldable PVC/galvanized steel flashing NOA No.: 20-0825.09 Expiration Date: 08/02/26 Approval Date: 03/04/21 Page 2 of 12 APPROVED INSULATIONS: Product Samatherm iDensDeck nensDeck Prime H-Shield TABLE 2 Product Description Isocyanurate Insulation with fiber reinforced felt paper facer Silicon treated gypsum with fiberglass mat facer Silicon treated gypsum with an enhanced fiberglass mat facer Isocyanurate Insulation with fiber reinforced felt paper facer Manufacturer (with current NOA) Sika Sarnafil, A Division of Sika Corp. Georgia Pacific Gypsum LLC Georgia Pacific Gypsum LLC Hunter Panels, LLC NOA No.: 20-0825.09 Expiration Date: 08/02/26 Approval Date: 03/04/21 Page 3 of 12 APPROVED FASTENERS/ADHESIVES: TABLE 3 Fastener Product Product Manufacturer Number Name Description Dimensions (With Current NOA) 1. #12 Standard Roofgrip, #14 Insulation and membrane Various OMG, Inc. Roofgrip, fastener # 15 Roofgrip 2. Sarnafastener #12 Insulation and membrane Various Sika Sarnafil, A Division + fastener of Sika Corp. 3. Sarnaplate Insulation fastening plate. 3" Round Sika Sarnafil, A Division of Sika Corp. 4. Sarnabar Galvanized or stainless steel Various Sika Sarnafil, A Division membrane fastening bar. of Sika Corp. 5. Sarnafastener #14 Insulation and membrane Various Sika Sarnafil, A Division fastener of Sika Corp. 6. OMG Heavy Duty Insulation and membrane Various OMG, Inc. fastener 7. Sarnafastener-XP Insulation and membrane Various Sika Sarnafil, A Division fastener of Sika Corp. 8. Sarnadisc-XPN Insulation and membrane 1.5" x 3.75" Sika Sarnafil, A Division fastener of Sika Corp. 9. Sikaplan Board Fastener Insulation and membrane Various Sika Sarnafil, A Divison of #12 fastener Sika Corp. 10. Sikaplan Fastener #14 Insulation and membrane Various Sika Sarnafil, A Division fastener of Sika Corp. 11. Flat Bottom Metal Plate Insulation fastening plate. 3" Round OMG, Inc. 12. 3 in. Ribbed Galvalume , Round galvalume plated steel 3" Round OMG, Inc. Plate stress plate 13. Sikaplan Board Plate Round galvalume plated steel 3" Round Sika Saranfil, A Division of stress plate Sika Corp. 14. RhinoBond Insulation Plate Black primer coated plate for 3" Round OMG, Inc. use with PVC membrane's 15. Sarnadisc RhinoBond Black primer coated plate for 3" Round Sika, Sarnafil, A Division of use with PVC membranes Sika Corp. 16. Sikaplan RhinoBond Disc Black primer coated plate for 3" Round Sika Sarnafil, A Division of use with PVC membranes Sika Corp. 17. OMG Eyehook Accuseam Round galvalume steel plate 23/8" Round OMG, Inc. " Plate for use with OMG fasteners 18. Sikaplan Disc Round galvalume steel plate 23/8" Round Sika Sarnafil, A Division of for use with OMG fasteners Sika Corp NOA No.: 20-0825.09 Expiration Date: 08/02/26 Approval Date: 03/04/21 Page 4 of 12 EVIDENCE SUBMITTED: Test Agency Factory Mutual Research A '(Underwriters Laboratories, Inc. Trinity I ERD PRI NEMOjetc. Test Identifier 3001396 3016201 3021131 3028309 3030053 3032532 3035670 3036355 R8992 S42480.08.12 S44790.06.13 S44790.08.13 S45990.06.14 S44790.07.14-R2 SARN-087-02-02 2-SIKA-18-001.01.19 Description FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 FM 4470 UL 790 Physical Properties ASTM D4434 ASTM D4434 ASTM D4434 ASTM D4434 FM 4474 / TAS 114 FM 4470 / TAS 114 Date 05/28/99 01 /28/03 07/07/05 03/30/07 09/12/07 08/05/08 05/13/09 11/10/09 05/15/13 08/20/12 06/05/13 08/26/13 06/02/14 06/01/15 06/22/18 01/03/19 NOA No.: 20-0825.09 Expiration Date: 08/02/26 Approval Date: 03/04/21 Page 5 of 12 APPROVED ASSEMBLIES: Membrane Type: Single Ply, PVC Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank System Type C(1): All layers of insulation simultaneously fastened; membrane adhered All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved a and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. "Thermal Barrier: Minimum 1/2" DensDeck or DensDeck Prime One or more layers of any of the following insulations: Base Insulation Laver: Insulation Fasteners Fastener Density/ft' able 3 Sarnatherm, H-Shield Minimum 1.5" thick N/A N/A Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density. Insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Top Insulation Laver (Optional): Sarnatherm, H-Shield Minimuml.5" thick Insulation Fasteners Table 3 5, 6,14,15 Fastener Density/ft2 See Design Pressure Note: Insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Membrane: Sarnafil S327, S327 Textured or S327 (10 ft) bonded to RhinoBond Insulation Plates with . RhinoBond Plate bonding tool at 6 seconds per plate so the tool reaches 400°F. Minimum 3" wide side lap is sealed with a minimum %" wide heat weld. 'Maximum Design $ressures: Maximum Pressure -45 psf (See General Limitation #7) Fastener Spacing Fastener Row Spacing 2 ft. 3 ft. NOA No.: 20-0825.09 Expiration Date: 08/02/26 Approval Date: 03/04/21 Page 6 of 12 Membrane Type: Single Ply, PVC Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank System Type C(2): All layers of insulation simultaneously fastened; membrane adhered All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. Fire Barrier: Minimum'/2" DensDeck or DensDeck Prime leOneor more layers of any of the following insulations: Base Insulation Laver: Sarnatherm, H-Shield Minimum 1.5" thick Insulation Fasteners able 3 N/A Fastener Density/ft' N/A Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density. Insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Top Insulation Laver (Optional): Insulation Fasteners Fastener Density/ft2 Table 3 Sarnatherm, H-Shield Minimum 1.5" thick 6, 10, 14,16 See Design Pressure Note: Insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Membrane: Sikaplan Fastened bonded to Sikaplan RhinoBond Disc, Sarnadisc RhinoBond with RhinoBond Plate bonding tool at 6 seconds per plate so the tool reaches 400°F. Minimum 3" wide side lap is sealed with a minimum %" wide heat weld. Maximum Design Maximum Pressure Pressures: -45 psf (See General Limitation #7) Fastener Spacing Fastener Row Spacing 2 ft. 3 ft. NOA No.: 20-0825.09 Expiration Date: 08/02/26 Approval Date: 03/04/21 Page 7 of 12 Membrane Type: Single Ply, PVC Deck Type 1I: Wood, Insulated Deck Description: Min. nominal 3/a" APA rated CDX plywood or wood plank at 2 ft spans, attached with 8d ring shank nails 6" o.c. System Type C(3): Insulation layer fastened through the deck, membrane adhered All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building • Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. 1 One or more layers of any of the following insulations: Insulation Layer: DensDeck Prime Minimum: 1/2" Thick Insulation Fasteners Fastener Table 3 Density/ft' 1 (#12), 2, 3 & 11 1:1.6 ft' Note: Insulation Layer shall be fastened to the deck; see top layer below for fasteners and density Insulation panels listed are minimum sizes and dimensions; if larger panels are used the number of fasteners per board shall be increased maintaining the same fastener density (See Roofing Application RAS 117 for fastener details). Membrane: Sarnafil G410, G410 Textured, adhered with 2170 VC in a contact -application at a rate of 0.75 — 2.0 gal/sq. to the insulation and 0.5 gal/sq. to the membrane backside. The roof cover is immediately placed into the adhesive and the top surface rolled with a weighted roller. Minimum 3" wide side lap is sealed with a 1.5" wide heat weld. Maximum Design Pressure: -67.5 psf (See General Limitation #7) NOA No.: 20-0825.09 Expiration Date: 08/02/26 Approval Date: 03/04/21 Page 8 of 12 Membrane Type: Single Ply, PVC Deck Type 1I: Wood, Insulated Deck Description: Min. nominal %" APA rated CDX plywood or wood plank at 2 ft spans, attached with 8d ring shank nails 6" o.c. System Type C(4): Insulation layer fastened through the deck, membrane adhered All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building • Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. One or more layers of any of the following insulations: r Insulation Laver: DensDeck Prime Minimum: 1/2" Thick Insulation Fasteners Fastener able 3 Density/ft2 1 (#12), 2,3 & 11 1:1.6 ft2 Note: Insulation panels listed are minimum sizes and dimensions; if larger panels are used the number of fasteners per board shall be increased maintaining the same fastener density (See Roofing Application RAS 117 for fastener details). Membrane: Sikaplan Adhered with Sarnacol 2170 VC in a contact -application at a rate of 0.75 — 2.0 gal/sq. to the insulation and 0.5 gal/sq. to the membrane backside. The roof cover is immediately placed into the adhesive and the top surface rolled with a weighted roller. Minimum 3" wide side lap is sealed with a 1.5" wide heat weld. Maximum Design Pressure: -67.5 psf (See General Limitation #7) NOA No.: 20-0825.09 M ;I EC Expiration Date: 08/02/26 Approval Date: 03/04/21 Page 9 of 12 Membrane Type: Single Ply, PVC Deck Type 1I: Wood, Insulated Deck Description: 15/32" or greater plywood or wood plank at 2 ft spans, attached with 2 3/s" ring shank nails 6" o.c. System Type D(1): Membrane attached over preliminary fastened insulation. All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building ' Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. r Fire Barrier: Minimum 1/4" DensDeck Prime, loose -laid. Membrane: Sikaplan Fastened (min. 60 mil) attached to deck as specified below. Fastening: Sikaplan Fastener #14, OMG Heavy Duty fasteners with Sikaplan Disc or OMG Eyehook Accuseam Plates spaced 12" o.c. within the 5.5" side lap spaced 54.5" o.c. and sealed with a minimum 1.5" weld. Maximum Design Pressure: -45 psf (See General Limitation #7) NOA No.: 20-0825.09 Expiration Date: 08/02/26 Approval Date: 03/04/21 Page 10 of 12 Membrane Type: Single Ply, PVC Deck Type 1I: Wood, Insulated Deck Description: 15/32" or greater plywood or wood plank at 2 ft spans, attached with 2 3/s" ring shank nails 6" o.c. System Type D(2): Membrane attached over preliminary fastened insulation. All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. Fire Barrier: Minimum 1/4" DensDeck Prime, loose -laid. Membrane: Sikaplan Fastened (min. 60 mil) attached to deck as specified below. Fastening: Sikaplan Fastener #14, OMG Heavy Duty fasteners with Sikaplan Disc or OMG Eyehook Accuseam Plates spaced 6" o.c. within the 5.5" side lap spaced 54.5" o.c. and sealed with a minimum 1.5" weld. Maximum Design Pressure: -75 psf (See General Limitation #7) NOA No.: 20-0825.09 Expiration Date: 08/02/26 Approval Date: 03/04/21 Page 11 of 12 GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer. 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. ,�4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each side lap It and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 121bs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 2751bf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below 2751bf. Insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117 and/or RAS 137. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended comers and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.: 20-0825.09 Expiration Date: 08/02/26 Approval Date: 03/04/21 Page 12 of 12