Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Fire Alarm Submitals
n Mi GENSET Integrated Solutions for Fire Alarm, Access Contro4 CCTV, and Nurse Call Systems FIRE ALARM SUBMITTALS Project: Commons at Oleander Automatic Sprinkler Monitor System 3801 Oleander AV, Port St. Lucie, FL, 34982. OWINI�I�IDIIIW��IIIWVIMII� gE-98T TN ife $Ofety & communloetlons e ®o CERTIFIED 1 3100 Gateway Drive, Pompano Beach, FL 33069 • Phone: 954-607-2958 • Fax: 954-968-6110 www.gensetfire.com 9 1010, 0 0 United Technologies Technology that saves lives Conventional Fire Alarm Systems FX-10RD, FX-10R, FX-5RD, FX-5R Overview Kidde brand conventional fire alarm systems consist of 5 and 10 zone fire alarm control panels (FACP), an optional integrated upload/download DACT (dialer), intelligent/analog type detec- tor features, serial annunciator modules, and serial remote relay modules. All FACPs and components are. Listed to the 9th edition of the ANSI/UL 864 standard and CSFM/FDNY approved. These systems incorporate features designed to simplify installation, operation and maintenance, including front panel programming, one person walk testing, and selectable IDC and NAC types. In addition, when used with CleanMe®-compatible smoke detectors, these con- trol panels provide intelligent type features such as remote mainte- nance alert and automatic drift compensation that significantly reduce the chance of a false alarm and simplify maintenance calls. Kidde systems are powerful enough to meet the demands of today's life safety installations while leaving plenty of room to grow in the future. They support Class A operation by combining pairs of on -board IDCs or NACs to provide the necessary Class A circuits. For example, the FX-10RD comes factory set to support 10 Class B IDCs and 4 NACs. But it can be field -configured to provide 5 Class A IDCs (no Class B IDCs), and 2 Class A NACs — or any other com- bination of circuits that fall within the circuit -pairing parameters. FX-10RD FX-5RD Class B IDCs Up to 10 Up to 5 Class A IDCs Up to 5 Up to 2 Class B NACs Up to 4 Up to 2 Class A NACs Up to 2 1 NAC Power 7.0 amps 3.5 amps Auxiliary power 0.5 amps 0.5 amps Kidde Catalog > Small Building Fire Alarm Solutions UDC FDNY COA 6230 Standard Features i • Available in 5, and 10 zone (IDC) models • CleanMe® feature provides remote 'annunciation of a dirty detector • Automatic drift compensation with select detectors reduces false alarms and extends dust fife I • Listed to ANSI/UL 864 9th Edition I • Models with fully integrated upload/download DACT enables PC programming • Zone or NAC pairs convertible to single Class A circuits • Combination Waterflow, and' Supervisory IDCs • NACs programmable by zone and individually selectable for notification appliances, continuous, temporal outputs, or coded • Front panel programmable simplifies installation and servicing • Precision synchronization with compatible notification appli- ances and optional audible silence over two wires • On -board relays for Alarm, Supervisory and Trouble • Optional serial bus relay modules are programmable for Com- mon, Zone, or Matrix activation • Optional serial bus remote annunciator family • One person walk -test (audible or eilent) • Optional City Tie and Reverse Polarity Modules • Trim ring available for semi -flush mounting I Notes. Class A operation will reduce the number of available Class B IDCs and/or NACs, depending on the panel configuration. See Specfcations for details. Page 1 of 8 DATA S H E E T K85005-0126 Not to be used for installation purposes. Issue 1 Application Kidde conventional fire alarm systems provide smoke and fire de- tection, occupant notification and off -premises signaling for small - to medium-sized buildings. Each IDC can be configured for either Class B or Class A opera- tion and one of eight operating modes: • Alarm —with or without smoke detector verification including discrimination of contact devices • Waterflow Alarm; • Waterflow Alarm/Supervisory (Combination IDC); • Supervisory (Latching/non-latching); • Monitor (non alarm or supervisory) • Signal Silence • Drill • Cross zoning NACs may also be configured for either Class B or Class A operation. Additionally, NACs can be individually configured for one of six outputs. These are Genesis, Genesis (AN silenceable), Continuous, Temporal, Coded, and City Tie. The Genesis selec- tion allows independent horn control over two wires and provides precision synchronization of notification appliances, all without the need for a signal master accessory. When configured for compatible notification appliances, the Alarm Silence function will silence connected audible appliances but strobes will remain active until the panel is reset. When Genesis Mode is selected, both the horns and strobes on compatible notifi- cation appliances will be synchronized across all NACs. Note: Zones may be selected for either latching or non -latching operation. Always check with your AHJ regarding approval of silencing audible while leaving strobes flashing. Detectors with intelligent features at a conventional price When combined CleanMe® -compatible smoke detectors, Kidde systems provide intel- ligent features at a conventional price. If a CleanMe® detector drifts out of the UL sensitivity range, Kidde's patented remote maintenance reporting sends an alert to the control panel. This feature reduces the chance of a false alarm and simplifies service calls. In addition, CleanMe® -compatible smoke detectors have built-in drift compensation that extends the time between cleanings. If cleaning is ever necessary, it is literally a snap with the Kidde exclusive replaceable optical chamber. For a complete list of CleanMe® compatible smoke detectors, visithttp://Kidde-fire.com. Panel LED Display The following system LEDs display the panel's status: • Alarm — panel is in the alarm state; • Trouble — panel is in the trouble state; • Supervisory — panel is in the supervisory state; • Power — indicates the status of the AC; power source; • Disable — indicates when any IDC, NAC, relay or the DACT is disabled; • Annunciator Trouble — indicates trouble on the remote an- nunciator bus; • Battery Trouble — indicates battery or charging problems; • Ground Fault — indicates a short between any panel circuit and ground; • Walk Test — indicates that one or more IDCs are in the walk test mode; • Alarms Silenced — indicates that the panel is in the alarm state with one or more NACs silenced. • Waterflow — indicates that one or more circuits have detected an active waterflow switch. • Service Detector— indicates the presence of a dirty detector with CleanMe® compatible ESL smoke detectors. • Remote Disconnect — indicates off site communication has been disabled. Each IDC has a disable switch and three LEDs: • Alarm — red — indicates that the IDC is in the alarm state; • Trouble —yellow — indicates that the IDC is in the trouble state or is disabled (when flashing); • Supervisory/Monitor — yellow — indicates that the IDC is in the supervisory state or the monitor state (when flashing). Each NAC also has a disable switch and a trouble/disable LED. Status indication with the DACT/Dialer installed The optional upload/download dialer's LCD display provides two lines x 16 characters of text. For programming, the top line displays the programming step and the lower line displays the selected option. All system events are displayed on the LCD with custom zone messages. During normal operation, the LCD will display any off -normal condition present in the panel. Page 2 of S o ATA SHEET K85005-0126 Not to be used for installation purposes. Issue 1 Power Connections N - L Cabinet Main AC From 120 Vac, 15 A. 60 Hz wiring block Dedicated branch circuit and fuse holder Fusa I � Dual transformer ° AC wiring block N2 1 L2 N L Main Tie wrap Main controller mounts transformer board .T=7a TB7 0 0 O 0 •. o` Mounting studs ED x o 0 0 0' Plug connector Upload/Download DACT/Dialer The DACT/Dialer installs be- hind the front panel display. Note: All panel versions are available with factory installed DACT. See order table for ordering informa- tion. The built-in DACT/Dialer is a multifunc- tion module that provides communi- cations, modem capability, and LCD display functions. Its primary function is as a Digital Alarm Communica- tor Transmitter (DACT). As a DACT, it transmits event messages to a Digital Alarm Communicator Receiver (DACR) at a monitoring facility. The monitoring facility then notifies the fire department and other responsible parties of the event. Programmable options include split or dual reporting to two DACRs. The DACT module can also be used as a modem to connect the panel to both local and remote computers for uploading and downloading of con- figuration data (programming), panel status and event history. For security, the modem can be configured to ac- cept programming on incoming calls or it can be required to call a prepro- grammed number before accepting downloads and sending uploads. The DACT module can be configured to work as all of the above, or as only an LCD display or LCD display and modem. Options Off -premise communication A fully integrated upload/download dialer is available for reporting events to a monitoring facility. The DACT also supports uploading or downloading of system configuration, status and event history. The DACT is programmable for either single or dual line opera- tion. It also supports split and dual reporting for two digital alarm receivers. The DACT brings additional features to the panel including a 32-character alphanumeric LCD display, local or remote PC pro- gramming and an event history log. Remote Annunciators and Relays The serial bus standard on Kidde conventional control panels is another installation time-saver. This circuit allows the connection of Remote System Indicators (FSRSI), Remote Zone Indicators (FSRZI- A, FSRZI-SA) and Remote Relay Modules (FSRRM24) over a four - wire (data and power) circuit. Annunciator and relay modules can be installed up to 1,000 feet from the panel on 1 B-gauge wire. Modules are also available for City Tie (CTM) and Reverse Polarity (RPM) connections. Remote Relay Module The Remote Relay Module (FSRRM24) ;.` is one feature of the system that sets `'�. these systems apart from other panels ' ;R! in their class. This module has five Form II )� C relays rated at 1 amp each. It can be )e configured to function in either a zone -- - relay mode or a common system mode. The Remote Relay Module When configured in the zone relay mounts on a plastic track g Y inside an MFC-A cabinet. mode, relays energize when the as- sociated IDC is active. The module can be configured for activation by IDCs 1 up to two through 5 or IDCs 6 through 10. One RRM24s can be mounted in an relay is automatically associated with FSRRM-S71 snap each IDC. track. Up to two FSRRM-Slls can be mounted in an When configured in the common •�S.Pv a MFc-a. system mode, relays energize or de -energize when the panel changes P�mud state. One relay is available for each of the following �w���- �mmw�� a, functions: Alarm, Supervi- sory, Trouble, Power Loss, P°"Y , Monitor. BOO r= W ®®� C 00001000 V' I©'NOOUCT'NO The FSRRM24 mounts on a plastic snap track and can be installed in an MFC-A enclosure. The panel will support two RRMs of each configuration for a total of six on the 10-zone panel. Page 3 of 8 DATA s H E E -r K85005-0126 Not to be used for instaliation purposes. Issue 1 P, M. Pamm a,I- remmu^esmat- �mm�nma.mo. m im,a ex.m FSRA10,FSRA10C Remote LED annunciators The FSRA10 is a remote annunciator with capacity for up to ten zones. It includes ten bi-color LEDs (red/yellow) for indicat- ing active zones, and ten yellow LEDs for indicating zone troubles. The (C) option adds common control switches. Both ver- sions mount to standard North American 4-inch square electrical boxes. A surface box is also available. Works only with 10 zone panel. FSRA10, FSRA10C Wiring From control panel or 24VDC supply From control panel IIR ! ! III II_I ii� I i � II II�1 %I II�1 %I Remote Annunciators This family of systems has several remote annunciation options. The serial - compatible electrical box remote annunciator bus can be run up to 1000 feet (305 m) on untwisted non -shielded 18-gauge cable. Several annunciator models round out the O family to provide a range of features and functions. As many as three an- nunciator modules may be mounted in a standard electrical box, sharing';; an attractive trim plate that blends with any decor. FSR51 The FSRSI can be installed alone or with one or more FSRZI-As. The FSRSI and FSRZI-A require trim plates (ordered separately). 'J These are available in one, two or three gang models. Each panel will support two FSRSIs. Remote System Indicator - Remote Zone Indicator (FSRSI) (FSRZI-A) The FSRSI is ideal for The FSRZI-A is used to common system annuncia- — indicate zones in the alarm tion. It includes five LEDs — state. It contains five red and a local silence/lamp —i LEDs. Depending on the _ test switch. The LEDs indi- _ jumper setting selected, cate power status, alarm, the LEDs will indicate either supervisory, trouble and "- IDCs 1 through 5 or IDCs 6 through 10. The panel can ground fault. The silence �"• switch will silence the P"' support two modules pro- m"°�'° onboard trouble sounder P°" " P^,,,,"• Pmmamw,.^v grammed for each selection. "- if active. The switch can also be used to initiate a `V1 ° m lamp test of the LEDs on :aF N INC e! OF all connected FSRSIs and FSRZI-As. Po.vwl- aommwlmanal mmmwezi"n a. m naaee.ra Remote Zone Indicator (FSRZI-SA) The FSRZI-SA indicates zones in the Alarm or Su- pervisory state. It contains five red and yellow LEDs for Common. Zone, or Matrix activation. Depending on the "- jumper setting, the LEDs will ��"• indicate either IDCs 1- 5 or 6 P°•° "' - 10. The panel supports two Pm xrm- F modules for each selection, and can be jumper selected PN IX ®q w to provide Alarm or Supervi- sory indications. Pamou. PaWmm- fNnmunWll^nwl- Cmnmunblbn oW . to mea..m FSUIM Graphic Driver/Interface The FSUIM is a universal interface module that can be used by to drive graphic annunciators. It also allows control panels to control, or be controlled by, other control panels. The FSUIM provides five supervised switch inputs and nine dry contact relay outputs. Nine LEDs provide visual confirmation when each relay is energized. The FSUIM is shipped with a plastic snap track for mounting in an MFC-A enclosure. From control panel or 24VDC aowe 24V 24V To next remote module C From control panel r C or 24VDC power supply From control panel ON: Group 1 OFF: Group 2 Page 4 of 8 DATA SHEET K85005-0126 Not to be used for installation purposes. Issue 1 Remote Annunciator Specifications General Agency Listings UL864 (S3000), ULC, CSFM Remote Annunciators FSRSI Remote System Indicator FSRZI-A/FSRZI-SA Remote Zone Indicator Maximum per System All panels: 2 10 zone panel: 4 5 zone panel: 2 Current Requirements Standby: 17 mA Alarm: 56 mA Standby: 8 mA Alarm 76 mA Voltage Range Minimum: 18.8 Vdc; Maximum: 27.3 Vdc Maximum Circuit Capacitance 0.03 pF Maximum Circuit Resistance 13 Ohms Wire Size 18 - 12 AWG (0.75 mm2 - 2.5 mm2) Mounting ANSI/NEMA OS1-1996 1-3 gang electrical box Operating Environment Temperature: 32 - 120° F (0 - 49° C); Humidity: 93% RH, non -condensing Remote Relay Module - FSRRM24 Configured for Zone Mode Configured for Common Mode Maximum per system 10 zone panel: 4; 5 zone panel: 2 All panels: 2 Current Requirements Standby: 10 mA; Alarm: 70 mA Standby: 26 mA; Alarm: 70 mA Voltage Range Minimum: 18.8 Vdc; Maximum: 27.3 Vdc Contact Rating 1 A @ 30 Vdc Maximum Circuit Capacitance 0.03 pF Maximum Circuit Resistance 13 Ohms Wire Size 18 - 12 AWG (0.75 mm2 - 2.5 mm2) Mounting Single FSRRM24 mounts in plastic track (included) or up to two FSRRM24s in an FSRRM-S11 11" track ordered separately. FSRRM24s should be installed in an MFC-A enclosure. Operating Environment Temperature: 32 -120° F (0 - 49° C); Humidity: 93% RH, non -condensing Dimensions 2-3/4" W x 3-3/8" H x 1-1/2" D (65.9 mm W x 85.7 mm H x 38.1 mm D) F-Series Remote Annunciators FSRA10 FSRA10C Common Controls No Yes Compatibility 10-Zone Panels Only. Dimensions 5-5/8" x 81/2" x 1 1/2" in (14.3 cm x 21.4 cm x 3.8 cm) Mounting North American 4-inch square electrical box Power Wiring 18 to 12 AWG (0.75 to 2.50 sq mm) Data Wiring 18 to 12 AWG (0.75 to 2.50 sq mm) twisted pair (6 twists per foot minimum) Operating voltage 18.8 to 27.3 Vdc Supply must be UVULC listed for fire protective signaling systems. Do not use FACP accessory power outputs that are interrupted when the panel is reset. Standby current 17 mA Alarm current 98 mA Operating environment Temperature: 32 to 120 T (0 W 49 °C); Humidity: 0 to 93% RH, noncondensing at 90 °F (32 0C) FSUIM Universal Input Module Mounting MFC-A enclosure Wire size 12 to 18 AWG (0.75 to 2.5 sq mm) Operating voltage 21.2 to 27.3 Vdc Circuit capacitance 0.03 pF, max. Circuit resistance 13 ohms, max. Switch inputs Quantity: 5 End -of -line resistor: 4.7 k ohms 1/2 W Relay outputs Quantity: 9 Type: Common Style: Form C Contact rating 30 Vdc at 1 A (resistive load) Standby Current 53 mA Alarm Current 114 mA Operating environment Temperature: 0 to 49 °C (32 to 120 °F); Humidity: 0 to 93% RH, noncondensing at 32 °C (90 °F) Page 5 of 8 DATA SHEET K85005-0126 Not to be used for installation purposes. Issue 1 Control Panel Specifications Control Panels FX-10RD FX-5RD Initiating Device Circuits - IDCs (Available combinations shown at right) Class B 10 8 6 4 2 0 5 3 1 Class A 0 1 2 3 4 5 0 1 2 Notification Appliance Circuits - NACs (Available combinations shown at right) Class B 4 2 2 0 2 0 Class A 0 1 1 2 0 1 Power Supply 7.5 amps total 4.25 amps total NAC Voltage Rating 24 Vfwr Maximum NAC current 2.0 amps each, 7.0 amps total 2.0 amps each 3.5 amps total AC Input 120 Vac 60 Hz... 230 Vac 50/60Hz... - 2.2 amps 1.1 amps 1.25 amps 0.6 amps Base Panel Current Draw Standby... Alarm... 128 mA 242 mA 104 mA 224 mA Panel Battery Charge Capacity (sealed lead acid only) Up to two 24 Ah batteries, 18 Ah in cabinet Up to 24 Ah, 10 Ah max in cabinet Auxiliary Current 0.5 amps max. May be programmed as resettable. Auxiliary Output 24 Vdc regulated IDC Alarm Current 3.0 mA (Consult detector compatibility list p/n 3101019-EN for maximum detectors per circuit) IDC Circuit Maximum loop resistance: 26 Ohms; Maximum loop capacitance: 0.03 uF IDC Operating Voltage 16.9 to 29 Vdc UL Detector ID 100 Alarm Contact (normally open Form C) 30 Vdc @ 1 A (resistive load) Trouble Contact (Form C) 30 Vdc @ 1 A (resistive load) Supervisory Contact (normally open Form C) 30 Vdc @ 1 A (resistive load) Operating Environment Temperature: 32 - 120° F (0 - 49° C); Humidity: 5 - 93% RH, non -condensing Terminals (wire gauge) 18 - 12 AWG (0.75 mm2 - 2.5 mm2) Asynchronous Serial Communications Maximum resistance: 13 Ohms; Maximum capacitance: 0.03 uF Agency Listings UL864 (53000), ULC-S527, CSFM, FDNY " If larger batteries are required, use an external battery cabinet. DACT - F-DACT (mounts in panel) Receivers Supports two receivers with two phone numbers each Communications Protocol Contact ID (SIA DC-05), 4/2 (SIA DC-02 P3) Programming Front panel controls or PC with appropriate software Telephone line connection Two RJ31X (plug -to -plug) cords supplied with DACT Telephone lines Two or one loop start lines on the public switched telephone network. Pulse or DTMF Telephone wall connector RJ31X/CA31X equiv. or RJ38X/CA38X equiv. Communications Compliance Industry Canada CS-03; FCC/CFR 47 Parts 15 & 68; NFPA 72; UL 864; ULC S527 Operating Environment Temperature: 32-120° F (0-49° C); Humidity: 93% RH, non -condensing Current requirements Standby: 65 mA; Alarm: 107 mA Agency Listings UL864 (S3000), CSFM, FDNY Dimensions D2- Model D1* D2 D3 D4 D5* Five- 19.5 in 3.75 in 9.13 in 10.5 in 14.23 in O . ° zone (49.5 cm) (9.5 cm) (23.2 cm) (26.67 cm) (36.14 cm) Ten- 30 in 3.75 in 7.75 in 21.27 in 15.0 in oR zone (76.2 cm) (9.5 cm) (19.7 cm) (54.0 cm) (38.1 cm) 4) Add 1 %2 inches (3.81 cm) to D7 and D5 dimensions for trim kit t rn c .c D1 'o E N 7 E 4) O� U) Page 6 of 8 D4 DATA SHEET K85005-0126 Not to be used for installation purposes. Issue 1 Ordering Information Part Ship Wt. lb. Number Description (kg.) Control Panels FX-10RD Conventional Fire Alarm Control Panel, Red -10 Class B IDCs and 4 Class B NACs, 7.OA NAC power, (Pairs of IDCs and NACs convertible to single Class A circuits), upload/download DACT/modem, 120VAC power source, 24VDC output 30.5 (13.8) FX-5RD Conventional Fire Alarm Control Panel, Red - 5 Class B IDCs and 2 Class B NACs, 3.5A NAC power, (Pairs of IDCs and NACs convertible to single Class A circuits), upload/download DACT/modem, 120VAC power source, 24VDC output 24.4 (11.1) F-TRIM35R Semi -flush trim ring for FX-5RD 1.7 (0.8) F-TRIM1 OR Semi -flush trim ring for FX-1 ORD 2.2 (1.0) Note: remove `D" in model number to order panel without the upload/download dialer in the panel Related Items F-XTR120 Expander Transformer, 120 Vac - For FX-10 only 4.0 (1.8) EOL3.6-1.1 Required UL listed End of Line Resistors - One 3.6K Ohm and one 1.1 K Ohm. One required for each IDC configured as combination waterflow and supervisory. 0.1 (0.5) EOL-P1 Required ULC listed End of Line Resistor Plate - includes one 1.1 K, 3.6K and 4.71K Ohm resistor 1.0 (0.5) Off Premises Communications F-DACT Upload/dowload digital Communicator/modem/LCD module (Mounts in control panel) 1.0 (0.5) CTM City Tie Module (Requires 4" square or 2-gang North American electrical box) 1.0 (0.5) RPM Reverse Polarity Module (Requires MFC-A or other listed fire alarm enclosure) 3.0 (1.4) Remote Annunciation FSRSI Remote System Indicator - Includes LEDs for display of Power, Alarm, Supervisory, Trouble and Ground Fault, trouble sounder and silence/lamp test switch. Single gang trim plate included, multi -gang plates ordered separately. Mounts in a single or multi -gang North American electrical box. 0.3 (0.1) FSRZI-A Remote Zone Indicator- Includes red LEDs for five IDCs. Single gang trim plate included, mufti -gang plates ordered separately. Mounts in single or multi -gang North American electrical box. 0.3 (0.1) FSRZI-SA Remote Zone Indicator - Includes LEDs for five IDCs. Single gang trim plate included, multi -gang plates ordered separately. Mounts in single or multi -gang North American electrical box. Jumper selected Alarm (red) or Supervisory (amber) indications. 0.3 (0.1) FSAT1 Annunciator Trim Plate, 1 gang 0.1 (0.05) FSAT2 Annunciator Trim Plate, 2 gang 0.1 (0.05) FSAT3 Annunciator Trim Plate, 3 gang 0.1 (0.05) FSAT4 Annunciator Trim Plate, 4 gang 0.1 (0.05) FSRA10 Single Unit 10 zone remote annunciator for FX-10 K-FSRA1 OC Single Unit 10 zone remote annunciator for FX-10 (with common controls) K-FSUIM Common Function Graphic Driver/Interface - 9 relays and 5 switch inputs for common system indicators and controls Remote Relay Module FSRRM24 Remote Relay Module - Five Form C relays. Configurable for IDCs 1-5, or 6-10, or common system indications or matrix mode. Requires MFC-A or other listed fire alarm enclosure. 0.4 (0.2) FSRRM-S11 11" Mounting track. Holds up to two FSRRM24s. 0.4 (0.2) Accessories MFC-A Multi -function Cabinet (fire alarm accessory enclosure) 7.0 (3.2) DATA S FI E E T K85005-0126 Not to be used for installation purposes. Issue 1 Page 7 of 8 -440 Kidde Technology that saves lives Contact us... Email: kidde.fire@fs.utc.com Web: Kidde.com/EnaineeredSvstems Kidde is a UTC brand. 1016 Corporate Park Drive Mebane, NC 27302 @ 2016 United Technologies Corporation. All rights reserved. Page 8 of 8 DATA SHEET K85005-0126 Not to be used for installation purposes. Issue 1 EST Catalog D Conventional Initiating ES T Life Safety dr Communications Fire Alarm Stations 270 Series Overview Edwards 270 Series Non -Coded Fire Alarm Stations are sturdy, attractive, and designed for economical installation. The station is available in the following operational and functional designs: — The 270 Series provides a single action, break glass initiat- ing station. It is available with normally open (N.C.), normally closed (N.C.) or combination N.O./N.C, contacts. The basic 270 Series have screw terminals for field connection. The 270A Series Manual Stations have 6 inch (150mm) wire leads. — The 270P Series is a break glass, normally open pre -signal station. The pull of the lever sounds an alarm on all pre -signal indicating devices. Inserting a key and turning it will initiate a general evacuation alarm. Screw terminals are provided for field connection. All non -coded statins are designed for either flush or surface mounting. For flush mounting a 4 inch standard North American square box with single gang plaster cover should be used. For surface mounting the 270 Series or 270P Series, use P-027193 Cast Box, P-039250 Steel Box, or Cat. No. 1291 Housing for weatherproof enclosure. Standard Features • Pull lever • Simple positive operation • Break glass • Attractive, streamline design • Less than 5 lb pull force complies with ADA • Solid, die-cast metal construction S2318 0 7150-1657: 0111 MEA FM Page 1 of 2 DATA SHEET 85001-0303 Not to be used for installation purposes. Issue 6 g m-1. UnitetlTechnologl0a. Contact us... Email: edwards.fire@fs.utc.com Web: www.est-rire.com EST is an EDWARDS brand. 1016 Corporate Park Drive Mebane, NC 27302 In Canada, contact Chubb Edwards... Email: inquiries@chubbedwards.com Web: www.chubbedwards.com @ 2013 UTC Fire & Security Americas Corporation, Inc. All rights reserved. Specifications subject to change without notice. Edwards is part of UTC Climate, Controls & Security, a unit of United Technologies Corporation. WARNING: These devices will not operate without electrical power. As fires frequently cause pow- er interruptions, we suggest you discuss further safeguards with your local fire protection specialist. Mounting —11 (2mm) I (3mm) 3-1/4' (92mm) DOOR RELEASE WALLSURFACE FOR TEST & RESET AND GLASS REPLACEMENT ((INCLUDED WITH YTONS) PRESIGNONLY ToNS) N GEN ALARM KEY SWITCH S.P.S.T. 4 1. PR� S GNUAD V ATIONS) (114mm) N = O e DETAILS FLUSH MTG. UNIT FITS 4" SO BOX & PLASTER COVER WITH P27165 GLASS ROD 0 SINGLE GANG OPENING HAVING OVERALL MIN. DEPTH OF 21/4" RUSH INSTALALTION USING P-024900 STEEL BOX F � (80MM0mm) I 4.12 (114mm) FRONT 3-112 (69mm) r (25mm) 0 0 SIDE STEEL SURFACE BOX P-030250 Ordering Information �tj� 3.9116• (mj � (26mmn) (90mm) 4-9116• (116mm) 0 O T- 0 FRONT CAST SURFACE BOX SIDE P-027193 All models are fire alarm red with Aluminum Strips. They are marked "Pull in Case of Fire" on the pull handle. Cat. No. Marking Switch Contacts Field Connections Pre - (top of Signal device) Single Double Open Screw Wire Pre - Pole Pole Circuit Terminals Leads Signal 270-DPO Fire Alarm ✓ ✓ ✓ 270-DPO- Local ✓ ✓ ✓ L Alarm 270-SPO Fire Alarm ✓ ✓ ✓ 270A-DPO Fire Alarm ✓ ✓ ✓ ,270A-SPO; ,Fire Alarm ✓ ✓ ✓ 270P-DPO Fire Alarm ✓ ✓ ✓ ✓ 270P-SPO Fire Alarm ✓ ✓ ✓ ✓ Page 2of2 DATA SHEET 85001-0303 Not to be used for installation purposes. Issue EST Catalog D Conventional Initiating EST TM Life Safety & Communications Two -Wire Self -Diagnostic Smoke Detectors 700 Series Overview The Edwards photoelectric smoke detector is an interchangable head and base detector with a light -scattering optical sensor that provides outstanding stability and excellent response to a wide range of fires. A pulsed infrared LED light source and a high-speed photodiode sensing element are housed in an omnidirectional sensing cham- ber which is protected by an insect screen. The chamber is not affected by ambient light. For easy cleaning, the detector features a field -replaceable optical chamber. The Model 711 UT and 721 UT photoelectric detectors include inte- gral fixed temperature heat detectors. The 721 UT provides remote alarm and trouble LED driver outputs. Edwards 700 Series smoke detectors are the industry's first conventional self -diagnostic detectors specifically designed for the demands of commercial and industrial environments. If the detector drifts out of its UL Listed sensitivity range or fails internal diagnostics, the alarm LED flashes once a second to indicate trouble. This meets NFPA 72 field sensitivity testing requirements without the need for external meters. Additional diagnostic information is activated by applying a magnet near the detector's integral reed switch. This initiates a self -diag- nostic routine and provides visual indication of sensitivity level, or if service is required. The magnet test causes the LED to blink. The number of blink counts corresponds to a smoke detector sensitiv- ity range. And, if they become dirty over time, the 700 Series detectors automatically adjust the alarm threshold through built-in drift com- pensation. FM MEA a Standard Features • Self -diagnostic capabililty continually monitors operation • Automatic drift compensation • Field -replaceable optical chamber • Low -profile design blends into the ceiling • Advanced nuisance alarm immunity • Extensive two -wire compatibility listings Pagel of 2 DATA SHEET 85001-0598 Not to be used for installation purposes. Issue 1.1 Engineering Specifications The Edwards 700 Series photoelectric smoke detector, is a low -profile, self -diagnostic, ® two -wire detector that monitors its own sensitivity and operational status. The detector A UTC Fire & Security Company meets NFPA 72 field sensitivity testing requirements without the need for external meters. Detection & alarm since 1872 Built-in drift compensation automatically adjust the sensitivity if the detector gets dirty. Normal sensing occurs every 9 seconds. This rate doubles when a signal exceeding the U.S. alarm threshold value is sensed. Two additional successive signals above the threshold T 888-378-2329 level initiate an alarm. The patented optical sensing chamber is field replaceable, allowing F 866-503-3996 quick and easy cleaning and maintenance. Canada Chubb Edwards A manually operated switch between terminals 1 and 2 shall establish continuity across T 519 376 2430 the alarm, initiating circuit at initial installation. The switch automatically opens when a F 519 376 7258 detector head is plugged in. If a detector head is removed from service, the switch will be reset using a small screwdriver, thus re-establishing circuit continuity. Southeast Asia T: +65 6391 9300 F : +65 6391 9306 India T: +91 80 4344 2000 F : +91 80 4344 2050 Australia T +61 3 92391200 F +61 3 92391299 Europe T +32 2 725 11 20 F +32 2 721 8613 Latin America T 305 593 4301 F 305 593 4300 utcfi reandsecurity.co m © 2010 UTC Fire & Security. All rights reserved. Technical Specifications Electrical Voltage 8.5 — 33VDC, non polarity sensitive Maximum ripple (peak to peak) 10% (Vp - p) Typical standby current (24V) 70pA Typical alarm current (24V) up to 60 mA max, if not limited by control panel Photoelectric Sensitivity 2.85%, + 0.37, -1.00% 32°F to 120T Operating humidity range 0 to 95% Non -condensing FIR immunity 20 V/m min; 0-1000 MHz Remote LED output current 5 mA min, 8.5 mA max Drift compensation adjustment 1.0%/ft. max Compatibility Heads: 711 U; Bases 701 U, 702U Environmental Heat Sensor Ratings (721 UT) Fixed 135°F/ Rate of rise 15' Maximum wind velocity 300 ft/min or Field wiring size 12-18 AWG Remote test input (721 UT) 100 ohm max Reset voltage 2.5V max Reset time 1 second max UL two -wire compatibility identifier S10A (711 U, 711 UT, 721 UT) Physical Color White head and base Detector head dimensions 4" D x 1.75" (4.44 cm) H Base dimensions 702E: 4" D, 0.6" (10 x 1.3 cm) H 701 U, 702U: 6" D. 0,6" x 1.3 cm) H Total height, (head and base) 1.98" (5 cm) H Listing UL 268, FM, CSFM, MEA approved Ordering Information Photoelectric Heads 711 U. 711 UT, 721 UT Photoelectric Bases: 701 U; 702U 211 G Replacement optical chambers (package of 10) a Page 2 of 2 DATA SHEET 85001-0598 Not to be used for installation purposes. Issue 1.1 DTK-HW Series VQItEK Equipment Pane//Dedicated Circuit Surge Protective Device Genera/ Product Specifications DITEK's HW series of surge protectors are designed and manufactured to meet the exacting standards of the life safety industry. These compact parallel mount surge protectors are widely used to protect fire alarm panels and other dedicated branch circuit loads. DTK-120HW DTK-120/240HW Product Features • Available for Popular 120V and 120/240V systems • DTK-120HW approved for 20A circuit breakers • Diagnostic LED indicates ground presence, system power and SPD function • Weatherproof enclosure • Small footprint enables installation in a variety of locations • Available for popular 120V, and 120/240V systems • Complies with ANSI/IEEE C62.41 and C62.45 Category B standards • Ten Year Limited Warranty 111 IIII � J Specifications Agency Approvals: UL 1449, 31d Edition, cUL IEEE Location Category: Category B Protector Type: SPD Type 2 Protection Modes: L-G, L-N, N-G Response Time: <1 ns Temperature Range: -40°F —185°F (-40°C — 85°C) Maximum Humidity: 95% non -condensing Operating Frequency: OHz — 40OHz Dimensions: 2.93" x 2.83" x 1.68" (74.4mm x 71.9mm x 42.7mm) Connection: Y4" diameter threaded fitting Weight:.51b. (227g) Housing: ABS Model Peak UL 1449, 3rd Short Circuit UL1449, Selection: Service Wiring Surge MCOV Ed. V.P.R. Current 3rd Ed. 1„ DTK- Current Rating Rating 120HW Single 0 19,500A 130V 700V L-N, L-G; 10,000A 3,000A (2W + G), 120VAC 600V N-G 13,000A/ 700V L-N, L-G; 120/240HW Split CD Phase 130/260V 0 10,000A 3,000A (3W + G), 120/240VAC 6,500A/ L-L Mode 1200V -L One DITEK Center 1-800-753-2345 1720 Starkey Road Technical Support: 1-888-472-6100 Largo, FL 33771 www.ditekcorp.com C UL US Document: SPS-100057-001 Rev 10 9/13 ©2013 DITEK Corp. Specification Subject to Change Voice, Data and Sienalin4 DTK-2M H LP24BW B Product Features ■ Protects two pairs per module ■ Multi -stage, SAD technology, hybrid design, provides the best possible protection ■ Field replaceable, modular edge card connection design with a single point ground for fast installation, saves time ■ Six voltage levels available to protect all types of voice/data applications ■ Hard -wired multi -base mounting system allows you to protect up to ten pairs with a common ground. See next page for base part numbers ■ Suitable for use on both AC and DC circuits Applications ■ Fire Alarm Panel NAC, SLC, PIV and IDC Circuits ■ Burglar Alarm Panels NAC and IDC Circuits ■ 4-20mA Current Loops Accessories DITEK's DTK-2MHLP series of signal, data and loop circuit surge protectors provide robust protection in a compact package. This series was designed for ease of installation, with convenient field -replaceable modules and a Snap -Track base system, allowing the installer to protect multiple circuits while utilizing a common ground point. DTK-2MHLP 513 'i 12B ;; 36B 48B 75B Service Voltage: i 5V 12V `24B 24V 36V 48V 75V MCOV: 6V 18V 33V 48V 64V 90V Clamping Voltage: 6.8V 21.6V 39V 57V 76V 108V Protection Modes: j Line -Ground (All) Surge Current Raing: 20,000 Amps Max Continuous s 5 Amps p Data Rate: 200kbps to 2Mbps Mechanical Characteristics Base Connection Method: 1 OAWG max screw terminals � Module Connection i Method: i Edge card into mounting base Housing: ABS Operating -40°F -158°F (-40°C - 70-C) Temperature: Maximum Humidity: ! 95% non -condensing j Module Module with Base Dimensions: ! 2.1"L x 1.4W x 1.9"H 3.25L" x 1.5"W x 2.6"H 1 (53mm x 36mm x48mm) (83mm x 38mm x 66mm) Wei ■ To order Module with Base, add "WB" to end of g !ht: ; 1.2 oz (34g) 2.8 oz (79g) L_---__-___� --_-J part number ■ Test Module Kit — Part Number DTK-2MHLPTM Quality, Standards & Approval ■ DIN Rail Mounting Kit — Part Number DTK-DRK Agency Approvals: i UL4976 Warranty: ; Ten Year Limited Warranty Every precaution has been taken to ensure that this literature Is accurate and complete. DITEK corporation assumes no responsibility and disclaims all liability far damages resulting from the use of this information or for any errors or omissions. One DITEK Center 1720 Starkey Road - Largo, FL 33771 Doc. Number. SPS-100010-001 Rev 13 01115 MADE IN Phone:1-800-753-2345 Direct 727-812-5000 ©2015 oft Corp. � F%%k 14 I Technical Support: 1-888-472-6100 Page 1 IT NCOUS www.ditekcorp.com U. S. A. Se V_nes Cl� ff,4odular:Surge Protection Part Number I # Pairs Protected k Dimensions 4 �ff X. ^�vi1 C) 0 EM 3 011 Iral www.ditekeorp.com lime I I WMS f » United Technologies J LIFE SAFETY y'�'INCIDENT MANAGEMENT Genesis LED G1 Series Compact Notification Devices Overview Genesis LED G1 Series horns and LED strobes feature a sleek low profile design and energy -efficient technology that makes them less expensive to install and operate by reducing overhead. High performance LEDs require fewer circuits and power supplies. These new appliances are designed with energy -efficiency and life safety in mind. Genesis LED G1 Series uses high efficiency optics, combined with patented electronics, to deliver a highly controlled and efficiently focused light distribution pattern in exchange for lower current requirements. Strobes feature field -selectable 15, 30, or 75 cd light output. Compared with Xenon -type strobes, Genesis LED G1 Series appliances need fewer power supplies and often smaller wire gauge, which lightens conduit requirements. They are also backwards compatible with legacy strobes, so there's no need to replace all your existing devices to upgrade to new LED technology. In fact, G1 strobes can be mixed on the same circuit and used in the same field of view as Xenon -based strobes. This makes Genesis LED G1 Series ideal for new installations and retrofits alike. Field -configurable sound output levels provide the flexibility modern' life safety projects demand, while the Genesis LED control protocol keeps multiple strobes on compatible NAC circuits synchronized to well within NFPA 72 requirements. Serviceability is another area where G1 Series appliances shine. The innovative under -cover diagnostic test points provide easy access to device circuit testing while mounted. EDWARDS' Catalog D Strobes, Horns, Bells, Chimes ALERT Standard Features c �L us S218, S5389 7125-1657:0506 7135-1657:0502 Li • High Performance LED Strobe Technology — Ultra low device current consumption — High efficiency optics — Selectable 15, 30, or 75 cd light output — LED devices may be mixed with legacy Xenon strobes • Efficient Audible Output — Selectable high or low dB horn output — Selectable temporal or steady horn output — Improved audio frequency range for better wall penetration • Low -profile Design — Compact design... single gang mounting — Ultra -slim... protrudes about 1 " from the mounting surface — Attractive appearance... no visible mounting screws • Multiple "FIRE" Marking Options — Order English, French, Spanish or no FIRE markings — Change markings at any time with quick -swap covers • Easy to Install — Diagnostic test points streamline device circuit testing — Fits standard 1-gang electrical boxes, no trim ring needed — Optional trim ring available for 4-inch square boxes — Slide switches for field configuration —12 to 18 AWG in -out screw terminals for quick wiring Page 1 of 6 DATA SHEET E85001-0667 Not to be used for installation purposes. Issue 1 Application Strobes Genesis LED G1 Series strobes are UL 1971-listed for use indoors as wall -mounted public -mode notification appliances for the hearing impaired. Prevailing codes require strobes to be used where ambient noise conditions exceed 105 dBA (87 dBA in Canada), where occupants use hearing protection, and in areas of public accommodation as defined in the Americans with Disabilities Act. Synchronization is important in order to avoid epileptic sensitivity. All Genesis LED strobes exceed UL synchronization requirements (within 10 milliseconds over a two-hour period) when used with a synchronization source. See the specifications table for a list of compatible sources. Horns Genesis LED horn output reaches as high as 92 dBA and features an improved audio frequency range compared with other Genesis LED horns. This results in excellent sound penetration through walls and a clear warning of danger. They can also be set for high or low dBA output. This setting reduces horn output by about 6 dBA. Horn -only models may be ceiling -mounted or wall -mounted and may be configured for either coded or non -coded notification appliance circuits. The suggested sound pressure level for each signaling zone used with alarm signals is at least 15 dBA above the average ambient sound level, or 5 dBA above the maximum sound level having a duration of at least 60 seconds, whichever is greater. These values are measured at five feet (1.5 m) above the floor. The average ambient sound level is A -weighted, fast response sound pressure measured over a 24-hour period. Doubling the distance from the signal to the ear will theoretically result in a 6 dBA reduction of the received sound pressure level. The actual effect depends on the acoustic properties of materials in the space. A 3 dBA difference represents a barely noticeable change in volume. Installation Genesis LED G1 Series horns and strobes mount to any standard one -gang surface or flush electrical box. Matching optional G1T trim rings are available to cover oversized openings and can accommodate one -gang or four -inch square boxes. Optional color matched single -gang surface boxes are also available. Wiring All Genesis LED devices come with mounting screws for easy installation. The tab at the bottom of the device unlocks the cover to reveal the mounting holes. The shallow depth of Genesis LED Horn/st devices leaves ample room behind them for extra wiring. Once circuit it installed with the cover in place, no mounting screws are visible. + One -gang Electrical Box Trim Ring Backplate Appliance Using a trim ring is optional 4-inch Octagon except when installing the Electrical Box signaling appliance on electrical boxes greater than three inches wide. 4-inch Square Electrical Box 3m/strobe cult out Signal polarity shown in the active condition. Page 2 of 6 DATA SHEET E85001-0667 Not to be used for installation purposes. Issue 1 Dimensions G1 Notification Appliances 1-vs• I (2.86 cm I 3" jam— j�(7.62 FIRE O DOOOOOOODo - oo 000000000000000 °0°00000°0°00000000000°000°0°0° Offlo 0000000 00000 0 G1T Trim Ring 9/16' (1.43 cm) 5• Diagnostics Field Configuration Temporal horn and horn -strobe models are factory set to sound in a three -pulse temporal pattern. By sliding the tone selector switch, horn -only units may be configured for constant horn output that can be coded at precise intervals by EDWARDS control panels and control modules. Horns and horn -strobes are factory set for high dB output. Low dB output may be selected by sliding the tone selector switch. This reduces the output by about 6 dBA. Genesis LED clear strobes and horn -strobes may be set for 15, 4-5/8• 30, or 75 candela output. The output setting is changed by simply (11.75 cm) removing the cover and sliding the candela switch to the desired setting. The device does not have to be removed from the wall to change the output setting. The setting remains visible through a small window on the left-hand side of the device after the cover is closed. T3 temporal horn, high dB T3 temporal horn, low dB Constant horn, high dB Constant horn, low dB V 2 cm) Test points indicated above are used to validate the Notification Appliance Circuit and verify device function. Page 3 of 6 75 candela 30 candela 15 candela Operating current Horns Sound 16 to 33 16 to 33 setting VDC VFWR C-LOW 13 mA 15 mA C-HIGH 23 mA 29 mA T-LOW 13 mA 15 mA T-HIGH 23 mA 29 mA M 1 6 d A IL Strobes Strobe 16 to 33 16 to 33 setting VDC VFWR 15, 30, 75 24 mA 32 mA Horn -Strobes, Strobe Sound setting 16 to 33 VDC 16 to 33 VFWR setting C-Low, T-Low 35 mA 43 mA 15, 30, 75' C-High, T-High 45 mA 55 mA DATA SHEET E85001-0667 Not to be used for installation purposes. Issue 1 Sound Output Reverberant dBA (UL 464) Sound setting Horn Horn -strobe j C-LOW 80 80 C-HIGH 86 86 T-LOW 80 80 T-HIGH 86 86 Anechoic dBA (CAN/ULC-S525) Sound setting Horn Horn -strobe j C-LOW 86 86 C-HIGH 92 92 T-LOW 86 86 T-HIGH 92 92 Sound pattern (ULC) Axis An Change in output Horizontal 45' and 115° -3 dBA 5° and 130° -6 dBA Vertical 65° and 135° -3 dBA Specifications 45° and 140° -6 dBA Light Distribution Horizontal Left 25 20 35 30 40 45 50 55 \ 60 65 \ 70 75 ` 80 \ 85 90 10 ° 5 io 15 20 25 Horizontal Right 30 35 40 45 \ 50 1 55 60 �j 65 70 80 i 85 90 Measured UL Minumum 90 10 15 20 F 5 65 Vertical Bottom Operating voltage 16 to 33 VDC, 16 to 33 VFWR Horn signal type Constant or T3 temporal Light output 15, 30, or 75 candela Strobe flash rate 1 fps (flash per second) approx. 20 S) max. between any two devices. Synchronization (To determine allowed wire resistance, refer to these specifications, and the specifications for the synchronized signal source.) Synchronization sources EDWARDS CC Series Signal Modules, Booster and Auxiliary Power Supplies, and Intelligent and Conventional Control Panels Wire size 12 to 18 AWG (0.75 to 2.50 mmz) Dimensions (WxHxD) 3 x 4-5/8 x 1-1/8 in. (7.62 x 11.75 x 2.86 cm) Strobe -to -box -0.71 inches (-1.8 cm) center offset Compatible electrical boxes [1] 1-gang, 2-gang, 4-inch octagon, 4-inch square Trim rings G-ITR, G1TW - Dimensions 5 x 5-7 x 9/16 in. (12.7 x 14 92 x 1.43 cm) Agency Listings FCC, ]CC, UL1971, UL1638, UL464, CSFM (All models comply with ADA code of federal regulation Chapter 28 Part 36 final rule) Operating environment Temperature 32 to 122°F (0 to 50oC) Relative humiditv 0 to 93% noncondensinq [1] Electrical boxes must beat least 1-1/2 in. (3.81 cm) deep. Electrical boxes greater than three Inches wide require a trim ring. Page 4 of 6 DATA SHEET E85001-0667 Not to be used for installation purposes. Issue 1 Ordering Information G1ARF Red FIRE 1 G1ARA-CVR Red ALERT G1ARF FR Red FEU G1ARF-CVR Red FIRE G1ARF-FR-CVR Red FEU G1ARF-SP Red FUEGO —'- t�; G1ARF-SP-CVR Red FUEGO G1ARN Red None G1ARN-CVR Red None G1AWF White FIRE -- --J G1AWA-CVR White ALERT Horns Selectable G1AWF-FR White FEU Horn G1AWF CVR White FIRE High/lowdB Covers i G1AWF-FR-CVR White FEU G1AWF-SP White FUEGO i G1AWF-SP-CVR White FUEGO G1AWN White None ; G1AWN-CVR White None G1VRA-CVR Red ALERT G1VRF Red FIRE G1VRF-FR Red FEU 1 G1VRF-CVR Red FIRE G1VRF-SP Red FUEGO G1VRF-FR-CVR Red FEU GiVRF-SP-CVR Red FUEGO - G1VRN Red None G1VRN-CVR Red None G1VWA* White ALERT G1VWA-CVR White ALERT Strobes G1VWF White FIRE Strobe G1VWF CVR White FIRE Selectable G1VWF-FR White FEU Covers G1VWF-FR-CVR White FEU 15, 30, 75 cd G1VWF-SP White FUEGO I G1VWF-SP-CVR White FUEGO G1VWN White None G1VWN-CVR White None GIAVRA-CVR Red ALERT GIAVRF Red FIRE GIAVRF-CVR Red FIRE GIAVRF-FR Red FEU GIAVRF-FR-CVR Red FEU GIAVRF-SP Red FUEGO GIAVRF-SP-CVR Red FUEGO ' GIAVRN Red None Ii L i GIAVRN-CVR Red None 'GIAVWF White FIRE I GIAVWA-CVR White ALERT Horn -strobes Horn -strobe i GIAVWF-CVR White FIRE Selectable ; GIAVWF-FR White FEU 15, 30, 75 cd, Covers ; GIAVWF-FR-CVR White FEU High/lowclB GIAVWF-SP White FUEGO GIAVWF SP CVR White FUEGO GIAVWN White None GIAVWN-CVR White None Accessories i G1TR Trim ring, G1 Series, red G1TW Trim ring, G1 Series, white 27193-11 One -gang surface mount box, red 27193-16 One -gang surface mount box, white Model Number Syntax, Appliances Genesis LED Series G1 = Wall mount appliances Housing Color R = Red W = White G1 AVRF Housing Marking u N F None *ALERT Marking F-FR =FEU available on white F-SP = FUEGO L strobe model with Functions F = FIRE clear lens only. A = Horn only A = ALERT* See replacement V = Strobe only covers for more AV = Ham -Strobe options. Model Number Syntax, Replacement Covers Genesis LED Series G1 = Wall mount appliances Housing Color R = Red W =Mite GIAVRF-CVR Cover Designation Cover Marking N = None Functions F-FR = FEU A = Hom only F-SP = FUEGO V = Strobe only F = FIRE AV = Horn -Strobe A = ALERT Page 5 of 6 DATA SHEET E85001-0667 Not to be used for installation purposes. Issue 1 LIFE SAFETY 8 INCIDENT MANAGEMENT Contact us... Email: edwards.fire@fs.utc.com Web: edwards-fire.com 1016 Corporate Park Drive Mebane, NC 27302 EDWARDS is a registered mark in the United States and other countries. © 2018 United Technologies Corporation. Al rights reserved. Page 6 of 6 DATA SHEET E85001-0667 Not to be used for installation purposes. Issue 1 Bells Vibrating 438 and 439 Series Edwards 438 and 439 Series fire alarm bells are Features and Specifications diode polarized, vibrating bells for use with fire 6", 8" and 10" gong sizes alarm equipment. They operate in conjunction Heavy duty die cast housing with an installed fire alarm panel and detection Steel alloy gong with epoxy powder coating devices. The steel alloy gongs are epoxy powder Back box available for use in outdoor finished and produce a loud, resonant tone applications required in fire alarm systems. Under dome mechanism • Available in red or gray • Lead length: 10" (25mm) Operating Gong Description Cat. No. Voltage Current Size Color dB at 1m/10ft. 438D-6N5 120VAC 0.034A 6" (152mm) Gray 76/661 438D-6N5-R 120VAC 0.034A 6" (152mm) Red 76/661 438D-8N5 120V AC 0.034 A 8" (203mm) Gray 85/751 AC 438D-8N5-R 120V AC 0.034 A 8" (203mm) Red 85/751 43813-10N5 120V AC 0.034 A 10" (254mm) Gray 891791 438D-10N5-R 120V AC 0.034 A 10" (254mm) Red 89/791 439D-6RAU 12V DC 0.150 A 6" (152mm) Red 95/85 43913-10RAU 12V DC 0.150A 10" (254mm) Red 96/86 439D-6AW 24V DC 0.085 A 6" (152mm) Gray 92/821 439D-6AW-R 24V DC 0.085 A 6" (152mm) Red 92/821 DC 439D-8AW 24V DC 0.085 A 8" (203mm) Gray 92/821 439D-8AW-R 24V DC 0.085 A 8" (203mm) Red 92/821 439D-10AW 24V DC 0.085 A 10" (254mm) Gray 95/851 439D-10AW� 24V D(0.085A 10" (254mm)) (Red 'Anechoic Chamber a Description Cat. No. Outdoor Back Box for DC Bells 449 h APPROVED www.edwardssignaling.com ' ®E—bWAR08 4-15 Bells Vibrating 438 and 439 Series Cat. No. Approx. Net Weight (lb.) Approx. Shipping Weight (Ib.) Depth Dimensions Width Height Length 438D-6N5 2.67 2.90 See Drawing 438D-6N5-R 2.67 2.90 See Drawing 438D-8N5 4.51 4.80 See Drawing 438D-8N5-R 4.51 4.80 See Drawing 43813-10N5 5.80 6.20 See Drawing 438D-IONS-R 5.80 6.20 See Drawing 439D-6RAU 2.67 2.90 See Drawing 43913-10RAU 5.80 6.30 See Drawing 439D-6AW 2.67 2.90 See Drawing 439D-6AW-R 2.67 2.90 See Drawing 439D-8AW 4.51 4.80 See Drawing 439D-8AW-R 4.51 4.80 See Drawing 439D-10AW 5.80 6.20 See Drawing L 9D-10AWlR 5.80 6.20 See Drawing 449 1.13 1.18 2" (51mm) 4 9/16" 4 1/2" (115mm) (114mm) i 10" (264mm) 8" (203mm) \ 6" (152mm) Gong Size \ 0 1 Mounting plate (furnished) mounts directly on surface or any single gang open 7 I---------- (178mm) I 7 I I T (127mm) I I I B I 3" 8 I Cat. No. 449 I 76mm) I Outdoor I I I I Back Box (optional) 2 29132" (74mm) (129mm) 311132" b 1/2" (85mm) (140mm) 3 15/32' 56181, (88mm) (143mm) 4-16 I;--- AR®S' www.edwardssignaling.com