HomeMy WebLinkAboutLetter- Response To Plan Examiner Review 2021-071110701 S Ocean Dr 716 2021-0711 To: Planning & Development Services From: Cash Construction LLC CC: Joseph Fersch (Examiner) Date: 04.19.2022 Re: Response to Plans Examiner Review from 02/22/2022 Plan Review, The following is a supplement to the plan submittal and in response to the questions asked by the plans examiner, Mr. Joseph Fersch: o The structure is attached to the existing residence o Rim Joist material is 2x6 SYP. Fastening per plans. o Joist material is 2x6 SYP. Fastening per plans. o Spacing of the joists is 16" o.c. o Details & notes for fall protection per plans o Riser size is to not exceed 7-3/4" per plans o Tread width is 10" per plans o Tread nosing is an optional 1" bullnose per plans o Stringers are 2x12 PT. Treads are to be ripped 2x12 SYP. Riser blocking to be W SYP. o Tread and risers attached to stringers w/ 10d RS nails o Risers are closed o Stringers fastened to the existing concrete drive per plan o Material for framing support per plans: • 2x4 stud wall per plan • 2x10 ledger attached to existing structure o Stringer material is 2x12 PT. Stairway will consist of (3) stringers. o Deck support provided by: • 2x4 stud wall per plan • 2x10 ledger attached to existing structure L01 R311.7.5 STAIR TREADS AND RISERS. STAIR TREADS AND RISERS SHALL MEET THE REQUIREMENTS OF THIS SECTION. FOR THE PURPOSES OF THIS SECTION, DIMENSIONS AND DIMENSIONED SURFACES SHALL BE EXCLUSIVE OF CARPETS, RUGS OR RUNNERS. R311.7.5.1 RISERS. THE RISER HEIGHT SHALL BE NOT MORE THAN 7% INCHES (196 MM). THE RISER SHALL BE MEASURED VERTICALLY BETWEEN LEADING EDGES OF THE ADJACENT TREADS. THE GREATEST RISER HEIGHT WITHIN ANY FLIGHT OF STAIRS SHALL NOT EXCEED THE SMALLEST BY MORE THAN Ya INCH (9.5 MM). RISERS SHALL BE VERTICAL OR SLOPED FROM THE UNDERSIDE OF THE NOSING OF THE TREAD ABOVE AT AN ANGLE NOT MORE THAN 30 DEGREES (0.51 RAID) FROM THE VERTICAL. OPEN RISERS ARE PERMITTED PROVIDED THAT THE OPENINGS LOCATED MORE THAN 30 INCHES (762 MI AS MEASURED VERTICALLY, TO THE FLOOR OR GRADE BELOW DO NOT PERMIT THE PASSAGE OF A 4-INCH-DIAMETER (102 MM) SPHERE. R311.7.5.2TREADS. THE TREAD DEPTH SHALL BE NOT LESS THAN 10 INCHES (254 MM). THE TREAD DEPTH SHALL BE MEASURED HORIZONTALLY BETWEEN THE VERTICAL PLANES OF THE FOREMOST PROJECTION OF ADJACENT TREADS AND AT A RIGHT ANGLE TO THE TREAD'S LEADING EDGE. THE GREATEST TREAD DEPTH WITHIN ANY FLIGHT OF STAIRS SHALL NOT EXCEED THE SMALLEST BY MORE THAN % INCH (9.5 MM). R311.7.5.2.1 WINDER TREADS. WINDER TREADS SHALL HAVE A TREAD DEPTH OF NOT LESS THAN 10 INCHES (254 MM) MEASURED BETWEEN THE VERTICAL PLANES OF THE FOREMOST PROJECTION OF ADJACENT TREADS AT THE INTERSECTIONS WITH THE WALKLINE. WINDER TREADS SHALL HAVE A TREAD DEPTH OF NOT LESS THAN 6 INCHES (152 MM) AT ANY POINT WITHIN THE CLEAR WIDTH OF THE STAIR. WITHIN ANY FLIGHT OF STAIRS, THE LARGEST WINDER TREAD DEPTH AT THE WALKLINE SHALL NOT EXCEED THE SMALLEST WINDER TREAD BY MORE THAN 3/8 INCH S.5 MM). CONSISTENTLY SHAPED WINDERS AT THE WALKLINE SHALL BE ALLOWED WITHIN THE SAME FLIGHT OF STAIRS AS RECTANGULAR TREADS AND DO NOT HAVE TO BE WITHIN 3/8 INCH (9.5 MM) OF THE RECTANGULAR TREAD DEPTH. R311.7.8 HANDRAILS. HANDRAILS SHALL BE PROVIDED ON NOT LESS THAN ONE SIDE OF EACH CONTINUOUS RUN OF TREADS OR FLIGHT WITH FOUR OR MORE RISERS. R311.7.8.1 HEIGHT. HANDRAIL HEIGHT, MEASURED VERTICALLY FROM THE SLOPED PLANE ADJOINING THE TREAD NOSING, OR FINISH SURFACE OF RAMP SLOPE, SHALL BE NOT LESS THAN 34 INCHES (864 MM) AND NOT MORE THAN 38 INCHES (965 MM). R311.7.8 HANDRAILS HANDRAILS SHALL BE PROVIDED ON NOT LESS THAN ONE SIDE OF EACH CONTINUOUS RUN OF TREADS OR FLIGHT WITH FOUR OR MORE RISERS. R311.7.8.1 HEIGHT. HANDRAIL HEIGHT, MEASURED VERTICALLY FROM THE SLOPED PLANE ADJOINING THE TREAD NOSING, OR FINISH SURFACE OF RAMP SLOPE, SHALL BE NOT LESS THAN 34 INCHES (864 MM) AND NOT MORE THAN 38 INCHES (965 MM), R311.7.8.3 GRIP -SIZE. REQUIRED HANDRAILS SHALL BE OF ONE OF THE FOLLOWING TYPES OR PROVIDE EQUIVALENT GRASP -ABILITY. 1. TYPE 1: HANDRAILS WITH A CIRCULAR CROSS SECTION SHALL HAVE AN OUTSIDE DIAMETER OF NOT LESS THAN 11/4 INCHES (32 MM) AND NOT GREATER THAN 2 INCHES 151 MM). IF THE HANDRAIL IS NOT CIRCULAR, IT SHALL HAVE A PERIMETER DIMENSION OF NOT LESS THAN 4 INCHES (102 MM) AND NOT GREATER THAN 61/4 INCHES (160 MM) WITH A CROSS SECTION OF DIMENSION OF NOT MORE THAN 21/4 INCHES (57 MM). EDGES SHALL HAVE A RADIUS OF NOT LESS THAN 0.01 INCH (0.25 MM). 2. TYPE 11: HANDRAILS WITH A PERIMETER GREATER THAN 61/4 INCHES (160 MM) SHALL HAVE A GRASPABLE FINGER RECESS AREA ON BOTH SIDES OF THE PROFILE. THE FINGER RECESS SHALL BEGIN WITHIN A DISTANCE OF 3/4 INCH (19 MM) MEASURED VERTICALLY FROM THE TALLEST PORTION OF THE PROFILE AND ACHIEVE A DEPTH OF NOT LESS THAN 5/16INCH (8 MM) WITHIN 7/81NCH (22 MM) BELOW THE WIDEST PORTION OF THE PROFILE. THIS REQUIRED DEPTH SHALL CONTINUE FOR NOT LESS THAN 3181NCH (10 MM) TO A LEVEL THAT IS NOT LESS THAN 13/4 INCHES (45 MM) BELOW THE TALLEST PORTION OF THE PROFILE. THE WIDTH OF THE HANDRAIL ABOVE THE RECESS SHALL BE NOT LESS THAN 11/4 INCHES (32 MM) AND NOT MORE THAN 23/4 INCHES (70 MM). EDGES SHALL HAVE A RADIUS OF NOT LESS THAN 0,01 INCH (0.25 MM). R312.1 GUARDS. GUARDS SHALL BE PROVIDED IN ACCORDANCE WITH SECTIONS R312.1.1 THROUGH R312.1.4. R312.1.1 WHERE REQUIRED. GUARDS SHALL BE LOCATED ALONG OPEN -SIDED WALKING SURFACES, INCLUDING STAIRS, RAMPS AND LANDINGS, THAT ARE LOCATED MORE THAN 30 INCHES (762 MM) MEASURED VERTICALLY TO THE FLOOR OR GRADE BELOW AT ANY POINT WITHIN 24 INCHES (610 MM) HORIZONTALLY TO THE EDGE OF THE OPEN SIDE, INSECT SCREENING SHALL NOT BE CONSIDERED AS A GUARD, R312.1.2 HEIGHT. REQUIRED GUARDS AT OPEN -SIDED WALKING SURFACES, INCLUDING STAIRS, PORCHES, BALCONIES OR LANDINGS, SHALL BE NOT LESS THAN 36 INCHES (914 MM) IN HEIGHT AS MEASURED VERTICALLY ABOVE THE ADJACENT WALKING SURFACE OR THE LINE CONNECTING THE LEADING EDGES OF THE TREADS. J I HIK & LHIVLJIiVh I U BE REMOVED FLOOREXISTING SEE PLAN FOR NUMBER OF TREADS/RISERS TYPE 1 HANDRAIL ON BOTH SIDES OF STAIR CASE & LANDING - SEE STAIR NOTES %"COX PLYWOOD SUBFLOOR GLUED AND SCREWED TO FLOOR JOISTS W/ #842" WD. SCREWS @ 6" O.C. ALONG EDGE AND IT O.C. I I IN FIELD SIMPSON STRAP LSC FASTENED WITH (8)10dx1Yz" NAILS GENERAL INTO TxlT NAILER, (8)10dx1Yz" NAILS INTO STINGER WIDE FACE, AND (1)10dx1Yz" NAILS INTO STRINGER NARROW _ FACE 2"x8" BLOCKING NAILED INTO STAIR 1. WEATHERING AREA IS NEGLIGIBLE TREADS W/ (4)10d NAILS TOP & BOT. 2. TERMITE AREA IS VERY HEAVY 3. ALL EXIT DOORS SHALL HAVE A LIGHT W/ A FLAT 36" X 36" LANDING. 4. ALL WOOD -FRAMING MEMBERS SHALL BE PRESSURE TREATED & ALL FASTENERS ARE TO BE CORROSION RESISTANT. PROTECTION FROM DECAY OPTIONAL 1" SHALL BE REQUIRED PER FBC/R-317 (FBC/R 2020). BULLNOSE 5. ACCESSIBILITY DOORS SHALL HAVE A 29" MIN. CLEARANCE. SIMPSON A24Z ANCHORED 10" MIN 6. THE SITE ADDRESS OR NUMBERS SHALL BE PLAINLY VISIBLE AND LEGIBLE TO EA STRINGER WI (2)10D ��1G FROM THE STREET OR ROAD FRONTING THE PROPERTY. RS NAILS & TO CONC. WIZ' 7. A CONTINUOUS PATH FROM FOUNDATION TO ROOF SHALL BE P\�C� X34"WEDGE ANCHOR 5- PROVIDED PER DETAILS AND CONNECTIONS SPECIFIED. 2"x4" LEDGE FASTENED TO CONIC WI (4)Y"O" TAPCONS 8. FRAMED WALLS SHALL USE STUD GRADE LUMBER SPACED AT 16" O.C.. N TCH RISER TO ACCEPT FRAMED BEARING WALLS SHALL BE BRACED WITH 2X4S @ A MAXIMUM 2X4 LEDGER 9. OF 8' O.C. - ° °.. "° _ 'EXI8T;4" CONE. 10, ALL NAILS SHALL BE HOT DIPPED GALVANIZED OR BETTER. I- 11, ALL SIMPSON FASTENERS SHALL BE Z-MAX WITH HOT -DIPPED GALVANIZED COMMON NAILS OR BETTER. 12. ALL BEARING WALLS SHALL HAVE A SIMPSON SP4/6 PLACED TOP AND BOTTOM OF FRAMED WALL AT 16" O.C.. HEADERS OVER 4' SHALL BE STRAPPED TO JACKS W/ SIMPSON MSTA24 AT ENDS W/ 8-1 Od NAILS PER SIDE. HEADERS UNDER 4' SHALL BE STRAPPED W/ SIMPSON LSTA18 W/ 7-1 Od NAILS PER END. EACH JACK SHALL HAVE A H2.5A @ THE BOTTOM PLATE. 13. CONTRACTOR TO VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS 14. NO SCREWS SHALL BE USED IN THE PLYWOOD SHEATHING OR WOOD MEMBERS OR ANY SIMPSON PRODUCTS UNLESS SPECIFIED IN THESE PLANS OR FROM THE MANUFACTURER. M I- _ PRESUMED SOIL BEARING CAPACITY @ 2500 PSI 2X6 NAILED FIXED TO DEL TOP PLATE & STUDS W/ 16D NAILS @ 6" O.C. SIMPSON LUS26 SLOPET"/12" 2X6 JOIST @ IT O.C. 2"x4" DBL. TOP PLATE - ATTACH TO STUDS WI SIMPSON SP4 2"x12" NAILER ATTACH TO VERT. STUDS W/ (3)160 NAILS EA. SIDE 2"x4" VERTICAL STUDS @ 16" O.C. P.T. 2"x4" SOLE PLATE FASTENED WIy"O" TACPONS @ 6" O.C. - ATTACH TO STUDS W/ SIMPSON EXISTING EXTERIOR WALL A/C SPACE EXIST. FLOOR EXIST. FOUNDATION GARAGElSECTION_ 2X10 PT LEDGER ATTACHED TO EXISTING CMU BEARING COLUMNS W/ (2) Z" X 6" WEDGE ANCHOR @ EA. CMU COLUMN, MAX. SPAN. 72" BETWEEN CMU BEARING COLUMNS CRAWL SPACE EXISTING GROUTED & REINFORCED 8X8 CMU COLUMN NEW FLOOR PLAN 311 = t 11-Orr 4 PERMITTING INFORMATION FLORIDA BUILDING CODE RESIDENTIAL: 7TH EDITION FBC/R 2020 AND ASCE 7-16 FOR WIND LOADING BUILDING DESIGN IS. OPEN RISK CATEGORY:11 WIND SPEED: 180 MPH ULTIMATE MEAN ROOF HEIGHT: N/A ROOF PITCH: N/A - INTERNAL PRESSURE COEFFICIENT: 10.18 SUBJECTABILITY TO DAMAGE FROM: WEATHERING: _YES_ TERMITES: -YES - WIDTH OF ROOF END ZONE: N/A WIND EXPOSURE CLASSIFICATION: C ADJUSTMENT FACTOR FOR EXPOSURE HEIGHT USING ALLOWABLE STRESS DESIGN AND LOAD COMBINATION PER ASCE 7.16 SECTION 2.4 DL+LL; DL+0.6WL; 0.6DL+0.6WL EXP HEIGHT ADJ FACTOR: _X LOAD COMBO FACTOR 0.6 =-APPLIED BELOW COMPONENTS AND CLADDING WIND PRESSURE (NET) ROOF ZONE: 1. N/A ROOF ZONE: 2. N/A ROOF ZONE: 3. N/A COMPONENTS AND CLADDING END ZONE WIDTH'. _ COMPONENTS AND CLADDING WIND PRESSURE (NET) WALL ZONE: 4. N/A WALL ZONE; 5. NIA COMPONENTS AND CLADDING WIND PRESSURE (NET) ON GARAGE DOOR: NIA SHEAR WALLS CONSIDERED FOR STRUCTURE?_ CONTINUOUS LOAD PATH PROVIDED? YES_ MINIMUM SOIL BEARING PRESSURE: _2500_ PSI PRESUMPTIVE- BY TEST: _ PSI THIS BUILDING SHALL HAVE THE FOLLOWING: APPROVED SHUTTERS: _ IMPACTGLASS:_ BOTH: _ NEITHER: -x SF ' 9s No 64781 = scott r OSTATE OF •fir Sar'dei �F �: O R This report has been electronically signed and sealed using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. 41_711 Digitally signed by Scott r sanders DAW,< 022.04.14 10:18:25-05'00' VIIEYvEDFOO CODE COM �I�C� 10701 S OCEAN OR (716) BOCC JENSEN BEACH, FL 34957 DRAWN BY: KLD DETA LS Project Sheet STAIR DETAILS Date 4/S/22 A I Scale = 1'0" U.N.O. cmW ­ ENGINEER SEAL: Engineer,. ( 4 ..; SOUTHEAST BUILDING PE-64781 �5as Rolling Acres Rd. .Pace, FL 32571 i72-7�4-9086 phone No. Revision/Issue Date