HomeMy WebLinkAboutCarolina Carport Generic PlansMAXIMUM ALLOWABLE TABLE 1 FBC APPROVED PRODUCTS LIST WIND SPEED RAFTER FRAME, END POST, GROUND ANCHOR AND PANEL FASTENER SPACING SPECIFICATIONS APPROVAL QA PARTIALLY AVERAGE FASTENER SPACING SUB CATEGORY MANUFACTURER EXPIRATION ON -CENTERS ALONG RAFTERS OR PRODUCT CATEGORY No. & DATE ATE OPEN ENCLOSED ENCLOSED PURLINS, AND POSTS OR GIRTS STRUCTURAL COMPONENTS ROOF DECK CAROLINA CARPORTS, INC. FL6596.1-R6 04/05/27 180 180 180 MAXIMUM (INCHES) 26 Gauge AG Panel 12/15/20 WIND ULTIMATE NOMINAL POST /RAFTER RISK EXPOSURE WIND SPEED WIND SPEED SPACING INTERIOR END STRUCTURAL COMPONENTS STRUCTURAL WALL CAROLINA CARPORTS, INC. FL6702.1-R6 03/14/27 180 180 180 CATEGORY CATEGORY (MPH) (MPH) (FEET) POSTS/RAFTERS POSTS/RAFTERS 26 Gauge AG Panel 12/15/20 110 TO 150 j 89 TO 116 1 5.0 6 6 STRUCTURAL COMPONENTS STRUCTURAL WALL CAROLINA CARPORTS, INC. FL6702.3-R6 03/14/27 N/A 164 143 1 C 26 Gauge Dutch Lap Wall Panel 12/15/20 .• 151 TO 180 117 TO 139 4.0 6 6 N/A STRUCTURAL COMPONENTS FLOOD VENT CRAWL SPACE DOOR SYSTEMS, INC. FL29622.1-R1 09/30/22 N/A N/A NOTES: 1. Specifications applicable to 26 gauge metal roof and wall panels fastened directly to 12 or 14 gauge steel tube framing, or 18 16x8 Flood Vent 02/28/21 gauge hat channel roof purlins. 139 2. Specifications applicable only for mean roof height of 20 feet or less, and roof slopes of 7° to 27' (1.5:12 to 6:12 pitch). Spacing EXTERIOR DOORS SWINGING ELIXIR DOOR AND METAL COMPANY FL17996.3-R2 08/26/25 N/A 139 requirements for other roof heights and/or slopes may vary. Series 402-14 02/28/21 . 174 GROUND ANCHOR SCHEDULE EXTERIOR DOORS SWINGING ELIXIR DOOR AND METAL COMPANY FL17996.5-R2 08/19/25 N/A 155 ULTIMATE WIND SPEED (mph) METAL CARPORT INSTALLATION PLANS Series 407 02/28/21 180 11.0 120 130 - 140 150 160 170 180 AND DETAILS AND FRAMING AND r EXTERIOR DOORS ROLL -UP ASTA INDUSTRIES INC. FL8888.1-R6 12/31/21 N/A 174 12 FASTENER SPECIFICATIONS Model 203 (12' Max. Width) 02/09/21 179 14 30:-An6hor " FOR CONSTRUCTION IN THE STATE OF FLORIDA EXTERIOR DOORS ROLL -UP CAROLINA CARPORTS, INC. FL16806.1-R5 04/05/27 N/A 154 16 . Detail1D Steel Roll Up Sheet Door (12' Max. Width) 12/16/20 v 180 PREPARED FOR: EXTERIOR DOORS ROLL -UP CAROLINA CARPORTS, INC. FL16806.2-R5 04/05/27 N/A -180 F=- 18 CAROLINA CARPORTS, INC. Steel Roll -Up Sheet Door - (8' Max. Width) 12/16/20 9 20 48' Anchor P.O. BOX 1263 155 Detail 1C DOBSON, NORTH CAROLINA 27017 FL16806.3=R5 04/05/27 N/A 133 EXTERIOR DOORS ROLL -UP CAROLINA CARPORTS, INC. z 12/16/20 Steel Roll -Up Sheet Door - (16' Max. Width) 0 24 180 d PREPARED BY., FL16806.4-R5 04/05/27 N/A 172 5 26 BECHTOL ENGINEERING AND TESTING, INC. EXTERIOR DOORS ROLL -UP CAROLINA CARPORTS, INC. ca _ Steel Roll -Up Sheet Door - (10' Max. Width) 12/16/20 605 WEST NEW YORK AVENUE 28 60 Anchor 175 Detail lC DELAND, FLORIDA 32720 WINDOWS SINGLE HUNG MI WINDOWS AND DOORS FL17499.1-R8 10/17/23 N/A 157 30 ep " I /Certificate of Authorization No. 00005492 Model .185SH 11/27/20 _ DETAILS'1C AND I SHOWN ON SHEET4 OF 6 6 REVIEWED �,O NOTES; 1. DOORS AND WINDOWS SHOWN MAY BE SUBSTITUTED FOR DIFFERENT PRODUCT LINES AND/OR MODELS, PROVIDED THE FOLLOWING CONDITIONS ARE MET: �'4 �+°� I� g� A. PROD UCT: SHALL HAVE AVALID FBC PRODUCT APPROVAL.. Co CO®� %.e�iA1n®����A� B. COMPONENTS ARE INSTALLED ACCORDING TO MANUFACTURER'S INSTALLATION. REQURIEMENTS. " MAXIMUM POST SPACING FOR DUTCH LAP IS 4.0' CE 2. F.RAMING CONNECTIONS FOR DOOR'AND WINDOW FRAMES REMAIN THE SAME FOR SUBSTITUTED PRODUCTS. HEADERS AND WINDOW RAILS MAY RAISED OR LOWERED AS NECESSARY TO ACCOMODATE S°T. LUCI E COUNTY . SUBSTITUTED PRODUCT. '.. :.GENERAL NOTES:: .. _.. .. .. . ���C r THESE PLANS PERTAIN ONLY -TO THE STRUCTURE, INCLUDING -.MAIN WIND FORCE RESISTING SYSTEM, COMPONENTS AND CLADDING; AND BASE RAILANCHORAGE. OTHER DESIGN ISSUES, INCLUDING BUT NOT LIMITED TO THIS -IS TO CERTIFY THAT THE'CALCULATIONS AND r�l 1. PLUMBING, ELECTRICAL, INGRESS/EGRESS, PROPERTY SET -BACKS, FINISH FLOOR ELEVATIONANDSLOPE, OR'OTHER.LOCAL ZONING REQUIREMENTS ARE THE RESPONSIBILITY OF OTHERS. SPECIFICATIONS: HEREIN HAVE"BEEN PREPARED BY THE UNDERSIGNED PROFESSIONAL ENGINEER, AND'ARE IN E' STRUCTURES ARE DESIGNED AS ,NON -HABITABLE UTILITY/STORAGE BUILDINGS (RISK CATEGORY 1) CAPABLE OF SUPPORTING DEAD.LOAD OF THE STRUCTURE AND APPLICABLE LIVE AND :WIND LOADS. IMPROVEMENTS. . ACCORDANCE WITH THE REQUIREMENTS OF SECTION 1609 OF 2, THESE T NOT SPECIFICALLYADDRE.SSE6 HEREIN, INCLUDING DOORS, WINDOWS, OR OTHER COMPONENTS NOT LISTED IN THE FBC APPROVED'PRODUCTS LIST (THIS. SHEET), AND NOT PROVIDED AND INSTALLED BY CAROLINA CARPORTS, THE FLORIDA BUILDING CODE, SEVENTH EDITION (20201. INC., WHICH EXERTADDITIONAL LOADS ON THE STRUCTURE SHALL BEAT THE OWNER'S RISK. BECHTOL'ENGINEERING AND TESTING, INC.; SHALL NOT BE RESPONSIBLE FOR STRUCTURAL'DAMAGE.OR FAILURE DUE TO THE 1 ;COPI APPLII.CATION OF:ADDITIONAL LOADS. lr,, F►�� 3: ALL ST EEL TUBING SHALL BE 50 KSI GALVANIZED STEEL., ALL. FASTENERS SHALL BE GALVANIZED OR STAINLESS STEEL OR ZINC PLATED. 4. ALL COMPONENTS AND.CLADDING SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND. SHALL MEET.THE DESIGN PRESSURES REQUIRED BY THE FLORIDA BUILDING CODE (FBC) AT THE v.•'' i.�cENs� ••., LOCATION OF THE BUILDING WITHIN THE STATE OF FLORIDA. _ No. _90753' 5, ALL FIELD FRAMING CONNECTIONS SHALL BE #12=14 x 3/4" SELF DRILLING SCREWS WITHOUT CONTROL SEAL WASHER. ALL SHOP FRAMING CONNECTIONS SHALL BE WELDED.. BED Oi ENGINEERING AND INC. g. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH. OF 2500 PSI AT.28, DAYS. THE REINFORCING STEEL SHALL BE MINIMUM GRADE 40. CONCRETE SLAB FOUNDATIONS SHALL BE REINFORCED WITH 6X6-W1 AXW1 .4 60s�r NEW YORK AVENUE (V WELDED'WIRE FABRIC COMPLYING WITH ASTM A 185, OR WITH SYNTHETIC FIBER REINFORCEMENT. COMPLYING WITH ASTM C1116. DELATI LORIDA 32Z2 0 7, BASE RAIL GROUND ANCHOR REQUIREMENTS: ONE WITHIN 6" OF EVERY. POST LOCATION, AND. BOTH SIDES OF OPENINGS WHERE BASE RAIL IS ABSENT. GROUND ANCHORS ARE NOT REQUIRED FOR CONCRETE FOOTING ice,' '., A �,= •. 'AND/OR CONCRETE SLAB'CONSTRUCTION.. SEE -GROUND ANCHOR SCHEDULE (THIS SHEET) FOR -SPECIFIC TYPE GROUND ANCHOR REQUIREMENTS. // 8. CONCRETE ANCHORS SHALL BE TAPCON REDHEAD LOT 1/2" x 5" OR EQUIVALENT OR WEJ-ITANKR-TITE MODELAT1252, OR SLEEVE ANCHOR MODEL HSA 1260, OR EQUIVALENT. g, POST/RAFTER BRACING: BRACE ON EVERY POST/RAFTER CONNECTION,. EXCEPT FOR END WALLS. 1p, SLAB FOUNDATION SUBGRADE SOILS SHALL BE TERMITE TREATED AND COVERED WITH.6 MIL VAPOR RETARDER PER SECTION R318.1 OF THE FBC SEVENTH EDITION (2020) - RESIDENTIAL AND SECTION 1816.1 OF THE FBC /+ SEVENTH EDITION' (2020) -BUILDING. MINIMUM ALLOWABLE FOUNDATION. SOIL'CONTACT BEARING PRESSURE OF 2;000 PSF IS ASSUMED. -CAROLINA CARPORTS; • LNC. 11. 14 GA FRAMING: 2-1/2' x 2-1/2" TUBE STEEL(TS).WITH.2-1W' x 2-1/4°.TS NIPPLES. GENERIC PLANS FOR USE IN: THE STATE OF FLORIDA 12 GA FRAMING: 2=1/4" x 2>1/4"-TS WITH 2" x 2" TS'NIP.PLES. _ °A" 6610412021 E UIRING FLOOD OPENINGS MUST.HAVE A MINIMUM OF.TWO (2) OPENINGS. ON EXTERIOR WALLS. OPENINGS SHOULD BE iNSTALCED ON AT LEAST TWO (2) SIDES OF ENCLOSED AREA, WITH BASE OF BECNTOC �FNGiNEER�NG °mow" riikb. NTs 12. ENCLOSED AREAS R Q su,E OPENINGS SET WITHIN 1-FOOT OF THE HIGHER OF INTERIOR OR EXTERIOR GRADE. REQUIRED TOTAL NUMBER OF FLOOD VENTS -NOTED IN.THE FBC APPROVED PRODUCTS LIST SHfALL'BE BASED ON ONE (1) FLOOD VENT PER "AND TEST/NG n Ib NO 621001 . ... mrvSiA.Y�NC GEOTECMvI°ei, ENnRpi NiA�A-MATER� $3E5YwGENQ" S .. EVERY 305. SQUARE FEET OVENCLOSED AREA: SEE TYPICAL FLOOD VENT FRAMING PLAN, SHEET'5.OF 6. � �•d.nw��w oao�s °"° E° TBSHEET1: OF 6'- BOW FRAME RAFTER OPEN CARPORT - HORIZONTAL ROOF BOW FRAME RAFTER ENCLOSED BUILDING - HORIZONTAL ROOF BOW FRAME RAFTER UTILITY BUILDING - HORIZONTAL ROOF FLOOD VENT (As applicable) ROLL -UP DOOR SWINGING DOOR ROLL -UP DOOR SWINGING DOOR (As applicable) (As applicable) (As applicable) — (As applicable) 77 — = ENCLOSED LENGTH TYPICAL SIDE ELEVATION TYPICAL END ELEVATION TYPICAL SIDE ELEVATION TYPICAL END ELEVATION TYPICAL SIDE ELEVATION TYPICAL END ELEVATION NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE BOX EAVE FRAME RAFTER OPEN CARPORT - HORIZONTAL ROOF BOX EAVE FRAME RAFTER ENCLOSED BLDG - HORIZONTAL ROOF BOX SAVE FRAME RAFTER UTILITY BLDG - HORIZONTAL ROOF FLOOD VENT (As applicable) ROLL -UP DOOR SWINGING DOOR ROLL -UP DOOR SWINGING DOOR (As applicable) (As applicable) (As applicable) (As applicable) 6• I'-6' _ _ _ I-6'— ENCLOSED-LENGTH VARIES — _- 0 TYPICAL SIDE ELEVATION TYPICAL END ELEVATION TYPICAL SIDE ELEVATION - TYPICAL END ELEVATION TYPICAL SIDE ELEVATION TYPICAL END ELEVATION NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE BOX EAVE FRAME RAFTER OPEN CARPORT - VERTICAL ROOF BOX EAVE FRAME RAFTER ENCLOSED BLDG - VERTICAL ROOF BOX EAVE FRAME RAFTER- UTILITY BLDG - VERTICAL ROOF FLOOD VENT (As applicable), ROLL -UP DOOR SWINGING DOOR ROLL -UP DOOR SWINGING DOOR � (As applicable) (As applicable) (As applicable). (As applicable)' ' _ - C OSED LENGTH ARIES { TYPICAL SIDE ELEVATION . TYPICAL END ELEVATION TYPICAL SIDE•ELEVATION; . TYPICAL END ELEVATION TYPICAL SIDE ELEVATION.. TYPICAL NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE yy�pNOT TO SCALE. NOT TO \r�1� 0 C O MPLIA G " BECNTOC ENGINEERING AND'Y 605 WEST NEW YORK AVENUE '� s LU6� p{ :CO� [{ T�!� D.ELAND,FLORIDA 32720 rj 114. l I �l1r CAROLIIVA CARPORTS; INC. GENERIC PLANS FOR USE IN THE STATE OF FLORIDA _ . TYPICAL BOW.RAFTER GABLE END ELEVATION TYPICAL BOX EAVE RAFTER.GABLE END ELEVATION TYPICAL BOX EAVE:RAFTER GABLE END ELEVATION N� EN NOT-TO.SCALE NOT TO SCALE NOT TO SCALE MV NO �yG, lna Gr E N 06/04/2021 ' Cli. NEER�NG mkb. Ts O TfSTI HECAE° tb Aw mo. G21001 - cMlsvLbNG �ErnEaWiCAI ENViRWNENinI AND MATERIALS jESTWG ENGYEERS C ' een rce a dA mudm No aooas sz AR` !. TB :. SHEET 2 OF 6 . . 4 26 GA. GALVANIZED METAL ROOF PANELS FASTENED TO RAFTERS PER MANUFACTURER'S INSTALLATION INSTRUCTIONS 12 \ Q3 \ 24" 16 GA U-CHANNEL BRACE FASTENED TO RAFTER WITH (2) #12-14 x 3/4" SDF's AT EACH END (4 PER BRACE) 24' MAXIMUM RAFTER SPAN ON SINGLE RAFTER >24' TO 30' RAFTER SPAN REQUIRES A TRUSSED RAFTER TYPICAL INTERIOR RAFTER/POST FRAME SECTION - BOW FRAME NOT TO SCALE LENGTH VARIES DEPENDING ON 26 GA. GALVANIZED METAL ROOF PANELS FASTENED TO RAFTERS PER MANUFACTURER'S NSTALLATION INSTRUCTIONS 12 2 �3 4 24" 16 GA U-CHANNEL BRACE FASTENED TO RAFTER WITH (2) #12-14 x 3/4" SDF'S AT = EACH END (4 PER BRACE) w 24' MAXIMUM RAFTER SPAN ON SINGLE RAFTER >24' TO 30' RAFTER SPAN REQUIRES A TRUSSED RAFTER TYPICAL INTERIOR RAFTER/POST FRAME SECTION - BOX EAVE - HORIZONTAL ROOF NOT TO SCALE LENGTH VARIES DEPENDING ON NUMtlEK AND SYALINU Uf- SEE TABLE 1 SHEET TYPICAL RAFTER/POST FRAMING PLAN -.BOW FRAME TYPICAL RAFTER/P05T FRAMING PLAN - bUA tAVE NOT TO SCALE NOT TO SCALE SEE SEE TABLE 1 TABLE 1 OPENING FOR SWINGING SHEET SHEET DOOR WITH NON-STRUCTURAL 1 �F 6 1 OF 6 HEADER s I • • N 12' MAX.OPENING. FOR ROLL -UP DOOR _WITH STRUCTURAL HEADER 10" (TYPICAL) OPENING FOR WINDOW WITH NON-STRUCTURAL HEADER AND WINDOW RAIL SIDE WALL OPENINGS FRAMING PLAN. (Also aooficatde to End Walls) _.... _...-._LD. S \� OPEN G 111R sv4wanc DOOR 12' MAX. OPENING FOR STRUCTURAL ' 111 UCTURAL ROLL -UP DOOR WITH HEADER NON-STRUCTURAL.\ 6' —� 3 N a SEE TABLE 1 SHEET 1 OF 6 I LENG VARIES DEPENDING ON NUMBER AND SPACING OF RAFTERS 26 GA. GALVANIZED METAL ROOF PANELS FASTENED TO PURLINS PER MANUFACTURER'S INSTALLATION INSTRUCTIONS 1-1/2" 18 GAUGE FURRING CHANNEL (PURLIN) `24" 16 GA U-CHANNEL BRACE FASTENED TO RAFTER WITH (2) #12-14 x 3/4" SDF's AT EACH END (4 PER BRACE) 24' MAXIMUM RAFTER SPAN ON SINGLE RAFTER >24' TO 30' RAFTER SPAN REQUIRES A TRUSSED RAFTER AS SHOWN ON THIS SHEET TYPICAL INTERIOR RAFTER/POST FRAME SECTION - VERTICAL ROOF NOT TO SCALE 1-1/2" 18 GAUGE FURRING CHANNEL FASTENED TO EACH RAFTER WITH (2) 012-14 x 3/4" SELF -DRILLING FASTENER SPACED NOT MORE THAN 48" O.C. I--6' TYPICAL POST/RAFTER FRAMING PLAN - VERTICAL ROOF NOT TO SCALE TYPICAL .END WALL OPENINGS POST/RAFTER FRAMING PLAN 'NOT TO SCALE TYPICAL BOW RAFTER GABLE END FRAMING PLAN NOT TO SCALE FILE Copy TYPICAL BOX EAVE RAFTER GABLE END FRAMING PLAN NOT TO SCALE REVIEWED F h CODE COMPLIANCE ACE T. L CIE COUNTY 13. 0cc. 24" 16 GA U-CHANNEL BRACE FASTENED TO RAFTER WITH (2) #12-1.4 x S4'.SELF=DRILLING SCREWS AT EACH END (4 PER BRACE) ROOF EXTENSION OPTION MAIN STRUCTURE TYPICAL LEANJO OPTIONS FRAMING. -PLAN (BOTH OP_ NOT TO SCALE (BOX EAVE RAFTER SHOWN, ONLY STANDARD LEAN-TO IS AP 24" 16 GA U-CHANNEL BRACE (V TO 7' POST) BECHTOL ENGINEERING 48" 16 GA U-CHANNEL.BRACE ' P (8' TO 14OST) BRACEANGLE SHALL BE MIN. 30• 605 WEST'NEWYORKAVENU TO MAX: 45" FROM HORIZONTAL' DELAND, FLORID. 32720 D 5 FREESTANDING v geoCT�G./ENS' LEiSN=TO.FRAMING PLAN.. CONSUL„„ GEO, �,t4�E„„RONNa A� ANDMA1ERI NOT T.O SCALE cen ca>'dnwma5Lmw ooaocs S S WIC IV M 'ArIA"00, E `Q�OW FFjATujE.RAItjQ ti . Irk 90713 'f OPTIONAL 24'-1" TO $0' TRUSSED RAFTER -- BOW NOT TO SCALE_' OPTIONAL 24'A." TO 30',TRUSSED RAFTER := BOX EAVE NOT TO SCALE' . INSTALL 1/2" x MINIMUM 5" TAPCON REDHEAD LDT ANCHOR OR 1/2" x MINIMUM 5-1/2" EXPANSION ANCHOR THROUGH BASE RAIL WITHIN 6" OF EACH RAFTER POSTS ALONG SIDES AND EVERY END WALL POST ALONG END WALL SECTIONS 4" MINIMUM —2" MINIMUM MINIMUM 2-1/2" EMBEDMENT 12" MONOLITHIC CONC. FOOTING (2500 PSI MIN.) REINFORCED WITH 2 #5's CONTINUOUS SCONCRETE BASE RAILANCHORAGE IAANot ToScale DRILL 5/8" HOLE THROUGH THE BASE RAIL AND SECURE TO ANCHOR EYE WITH 1/2" DIAMETER THROUGH -BOLT MINIMUM INSTALL 1/2" x MINIMUM 5" TAPCON REDHEAD LDT DRILL 5/8" HOLE THROUGH THE 2" WASHERS ANCHOR OR 1/2" x MINIMUM 5-1/2" EXPANSION ANCHOR DRILL 5/8" HOLE THROUGH THE 2" WASHERS THROUGH BASE RAIL WITHIN 6" OF EACH BASE RAIL AND SECURE TO BASE RAIL AND SECURE TO RAFTER POSTS ALONG SIDES AND EVERY END ANCHOR EYE WITH 1/2" DIAMETER TS CONTINUOUS ANCHOR EYE WITH 1/2" DIAMETER TS CONTINUOUS WALL POST ALONG END WALL SECTIONS THROUGH -BOLT BASE RAIL THROUGH -BOLT BASE RAIL \ F—+MIN. 6" TOP OF ASPHALT PAVEMENT TOP OF ASPHALT PAVEMENT OR STABLE GROUND SURFACE, OR STABLE GROUND SLIFACE\ 2-1/2" EMBEDMENT MINIMUM 4" CONTINUOUS 4" CONCRETE PAVEMENT 1 _ CONCRETE BASE RAILANCHORAGE Not To Scale (OPTIONAL - OPEN CARPORTS ONLY) 2" WASHERS 24" 16 GA U-CHANNEL BRACE (5' TO 7' POST) 48" 16 GA U-CHANNEL BRACE (8' TO 14' POST) TS CONTINUOUS BRACE ANGLE SHALL BE MIN. 45° BASE RAIL TO MAX. 60° FROM HORIZONTAL NIPPLE TO 3_ RAFTER V (SEE GROUNDANCHOR SCHEDULE, SHEET 1 OF 6, FOR REQUIRED ANCHOR) CONTINUOUS 4" CONCRETE PAVEMENT . EYE ANCHOR 1E CONCRETE BASE RAILANCHORAGE Not To Scale (OPEN CARPORTS WHERE SLAB EDGE DISTANCE DOES NOT MEET MINIMUM EDGE DISTANCE SHOWN IN DETAIL 1B) TS TRUSSED RAFTER CHORD, OR NON-STRUCTURAL HEADER— TS END POST OR DOOR/ WINDOW FRAME POST TS 13ASEIWINDOW RAIL OR - - NON-STRUCTURAL HEADER (12 GA IF ROLL -UP DOOR FRAME) - 2"x2"x2" 16 GAANGLE CLIP SECURE TO POST (EACH SIDE) AND RAFTER CHORD/RAIL WITH '(4). #12-14 x 3/4" SDF's, (2) ON T.OP OR BOTTOM, (2) ON SIDE POST TO RAIL,. TRUSS CHORD, OR N.ON=STRUCTURAL HEADER CONN. DETAI Not To Scale ' TS RAFTER �6" LONG TS NIPPLE SECURE POST TO NIPPLE WITH ' (4) #12-14 x 3/4" SDF's TS RAFTER POST BOX.EAVE RAFTER/POST: DET/ALL 2A Not To Scale TS RAFTER POST 1-1/2" x 1-1/2" x 2" 16 GA CLIP ANGLE SECURE TO POST AND BASE RAIL WITH (4) #1214 x 314" SDF's, (2) ON TOP, (2) ON SIDE ITS CONTINUOUS BASE RAIL 5 END POST/BASE,.RAIL CO.NN. Not To Scale EYEANCHOR 5/8" ROD 48" LONG WITH 6" HELIX OR 5/8" ROD 60" LONG (SEE GROUND ANCHOR WITH 7" HELIX, SCHEDULE, SHEET 1 OF 6, AS APPLICABLE FOR APPLICABILITY) 1C BASE RAIL DEEP ANCHORAGE Nat To Scale TS BOW RAFTER NO SCREWS REQUIRED IN BOW BEND EYE ANCHOR U (SEE GROUND ANCHOR 5/8" ROD 30" LONG SCHEDULE, SHEET 1 OF 6, WITH DBL 4" HELIX FOR APPLICABILITY) �:f_ 1D BASE RAILANCHORAGE Not To Scale FILE®ly 6" LONG TS NIPPLE SECURE POST TO NIPPLE WITH (4) #12-14 x 3/4" SDF's 4" 16 GA U-CHANNEL BRACE (5' TO 7' POST) 48" 16 GA U-CHANNEL BRACE (8' TO 14' POST) TS RAFTER POST 9-1 /2"7r BRACE ANGLE SHALL BE MIN. 45° NIPPLE TO MAX. 60° FROM HORIZONTAL BASE RAIILL \ 3/� ii LONG TS NIPPLE SECURE RAFTER AND POST TO NIPPLE WITH (4) #12-14 x 3/4' TS.RAFTER POST SELF -DRILLING FASTENERS B4O.W.RAFTER/POST DETAIL 26 _Not To Scale POST 2" x 2" x,2" 16 GAANGLE,CLIP SECURE TO POSTAND TOP OF HEADER, OR BOTTOM OF WINDOW RAII./GIRT WITH (4) #12-1.4 x 3/4"'SDF's (2) ON TOP OR BOTTOM, (2) ON SIDE �TS NON. -STRUCTURAL HEADER TS WINDOW RAIL OR GIRT FOR VERTICAL SIDING OPTION NON-STRUCTURAL HEADER, WINDOW s RAIL, OR GIRT TO POST.CONN.. DETAIL Not To Scale TS CONTINUOUS BASE RAIL POST/BASE RAIL CONN. DETAIL 3 'Not To Scale REVIEWED FOR . COWE C® PLIBACE � r No..90753 BtC^L' ENGINEE1*NG .. INC. 805 V N6W YORK AVEN ' DELA*D CIRIDA 327 i AT � l I. sc ' I .: ancc:�i 4urc VERTICAL SIDE OPTION SEE TABLE 1 OPENING FOR SWINGING DOOR SHEET WITH NON-STRUCTURAL HEADER 7. 1OF6 5 4 4 GIRTS 6 4 ci E (Typical) 4 4 s 9 12' MAX. OPENING FOR ROLL -UP DOOR WITH . s 3 NON-STRUCTURAL HEADER 4 4 4 4 TYPICAL END WALL OPENINGS POST/RAFTER/GIRT FRAMING PLAN NOT TO SCALE BOX EAVE FRAME RAFTER ENCLOSED BLDG - VERTICAL SIDES 1-1/2" 18 GAUGE FURRING CHANNEL FASTENED TO OPENING FOR SWINGING DOOR EACH RAFTER WITH (2) #12-14 x 314" SELF -DRILLING WITH NON-STRUCTURAL HEADER 6'-j FASTENER SPACED NOT MORE THAN 48" O.C. GIRTS (Typical) 5 4 SEE TABLE 1 SHEET 1 OF 6 e s 6 3 E d E e 5 12' MAX. OPENING FOR ROLL -UP DOOR WITH STRUCTURALHEADER 4 4 4 5 to 4 3 3 4 3 4. 4 3 4 5 4 OPENING FOR WINDOW WITH NON-STRUCTURAL HEADER LENGTH VARIES DEPENDING ON NUMBER AND WINDOW RAIL AND SPACING OF RAFTERS (Also applicable to End Walls) TYPICAL POST/RAFTER/GIRT FRAMING PLAN , NOT TO SCALE REVIEWED f-UH CODE COMPUA OE STo LU09E CouNTY CC BOX EAVE FRAME RAFTER UTILITY BLDG VERTICAL SIDES ROLL -UP -DOOR SWINGING DOOR (As applicable), (As applicable), TYPICAL SIDE ELEVATION NOT TO SCALE TYPICAL END ELEVATION NOT TO SCALE ,v-e`c grl�,,, . v......, r4 5. BEGH*L%ENGINEER1NG AN �+, INC. 605 VM'NS W SW YORK AV&4M - DEL �idD!WOI2IDA 32720 SjLZ T... p' z1f ft, LFF,5": ARO NA CAI BFCHI�C ENG/NEFR AND TBSVNQ Inc. ' ' GGNSULTNG GEOTECHNiCA4 ENVigCNmENinL.IWO MwTERUlL41E5IWGEM . - _ uns : <gaywlcew"w EOOf6t41 . NO G21001 $HE�T6OF6