Loading...
HomeMy WebLinkAboutCertification Design Load CompliancePlanning & Development Services Delpartment Building & Code Regulations Diviision 2300 Virginia Avenue, Fort Pierce, FL 34992 — (7721462-1553 Certification for Design Load Compliance Project Name: Peluso Commercdial Building Project Address: Gommerciai Cirr, e% Ft. Pierce, FL Permit #: Occupancy Type: B Construction Type: V INSTRUCTIONS FOR USE: * Th& certr(rcatrorr must be eamWeted, srgrred, artd seared try the desr�m Irra ssrorrat of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring, a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contaict the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: jcomplete all that apply,) 1. DESIGN CODE: Florida 2014 Code Fifth Edition with 20 14 Supplements using ASCE 7-10 2. Structure Designed as (check one): x Enclosed Partially Enclosed Open 3. Risk Category: _I X II III IV Exposure Category: B x C D 4. Design Wind Velocity 160 mph x ASD LRFD End Zone Width: 4 ft S. Mean Roof Height 18 ft Roof Pitch: 2 :12 Parapet: 0 ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MR li, clearly label on all plan openings): 2e 1: -32.7 2af7e 2: -56.9 2Ane 3. -64.0 7 4.• +41.2, 45.1 2m.�e 5. +41.2,-57.8 �i2f 2bQe. +22.8,-25.f 7. Design Loads: Floor: 100 PSF Roof/Dead: 5 PSF Roof/Live: 10 Balcony: N'" PSF Dock: NSA PSF Deck: NSA PSF Stairs: NSA PSF Fence: NSA PSF Railings: NSA PSF 8. Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain '&y N, ot: /. YSiii.'1` 10. Design Soil Bearing Pressure: 2000 PSF Soil Test Reports Submitted %6 " es, '.0 w DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structI elements depicted on these plans provide ;adequate resistance to the design 4asces STEPHEN A GAYDOSH, JR, PE-GC-PCC-CBI-StS1 FLA PE - 038464 6TEPHEHA.OAY SH.J . Signature, Date, and Seal Print Name SAGE ENGINEERING Cert # & Co. Cert Auth. 406 S 13th PLACE, LANTANA, FL 313462-3006 Company Name & Address Revised 07/25/2014