Loading...
HomeMy WebLinkAboutEnergy Efficiency CodeFORM 405-10 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION ,-Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: MR AND MRS STROIK Builder Name: Street: 10701 S OCEAN DR. LOT 15 Permit Office: st. Iucie co. / ft. pierce City, State, Zip: JENSEN BCH. , FL , 34957- Permit Number: Owner: SAME Jurisdiction: 661100 Design Location: FL, Fort Pierce 1. New construction or existing New (From Plans) 9. Wall Types (2638.5 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.0 1451.10 ft' b. Frame - Wood, Exterior R=11.0 959.38 ft' 3. Number of units, if multiple family 1 c. Concrete Block - Ext Insul, Exterior R=11.0 198.00 ft' 4. Number of Bedrooms 2 d. other (see details) R= 30.00 ft' 10. Ceiling Types (848.0 sqft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=0.0 848.00 ft: 6. Conditioned floor area above grade (ft') 1522 b. NIA R= ft' c. N/A R= ft' Conditioned floor area below grade (ft') 0 11. Ducts R ft' 7. Windows(482.8 sqft.) Description Area a. Sup: Attic, Ret: Main, AH: Main 6 164 a. U-Factor: Dbl, U=0.87 442.75 ft' SHGC: SHGC=0.29 b. U-Factor: Sgl, U=0.87 40.00 ft' 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.29 a. Central Unit 37.6 SEER:15.00 C.. U-Factor: N/A ft' SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft' a. Electric Strip Heat 28.0 COPA.00 SHGC: Area Weighted Average Overhang Depth: 1.919 ft. Area Weighted Average SHGC: 0.290 14. Hot water systems a. Electric Cap: 66 gallons 8. Floor Types (1522.0 sqft.) Insulation Area EF: 0.920 a. Raised Floor R=21.0 848.00 ft' b. Conservation features b. Floor over Garage R=21.0 674.00 ft' None c. NIA R= ft2 15. Credits CF, WHF, Pstat Glass/Floor Area: 0.317 Total Proposed Modified Loads: 36.77 PASS Total Standard Reference Loads: 46.74 1 hereby certify that the plans and specifications covered by Review of the plans and F'TKE SrAT this calculation are in compliance with the Florida Energy specifications covered by this -4V Code. calculation indicates compliance y�a„ '' ,-,�''���•�`�� ��. with the Florida Energy Code.10 •+n+++'!• ;;,'� a PREPARED y: Before construction is completed -- DATE: this building will be inspected for - compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. ✓,� �� COD with the Florida Energy Code. W6'C�� OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with 403.2.2.1.1. - Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist - Compliance requires a roof absorptance test and a roof emittance test in accordance with 405.6.2 - Compliance .requires an air distribution system test report, by a Florida Class 1 Rater, confirming system leakage to'outdoors tested at 25 pascals pressure difference in accordance with 403.2.2.1. is not greater than (46 cfm:Duct#1) AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 6 PROJECT Title: MR AND MRS STROIK Bedrooms: 2 Address Type: Street Address BUilding Type: User Conditioned Area: 1522 Lot # 10 Owner: SAME Total Stories: 2 Block/SubDivision: # of Unt�.,: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 10701 S OCEAN DR. L Permit Office: st. lucie co. / ft. pierce Cross Ventilation: No County: st. lucie Jurisdiction: 661100 Whole House Fan: Yes City, State, Zip: JENSEN BCH. , Family Type: Single-family FL, 34957- New/Existing: New (From Plans) Comment: CLIMATE V IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_ST_LUCIE CO INTL 2 39 90 70 75 722 62 Low BLOCKS Number Name Area Volume 1 Blockl 1522 12176 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 674 5392 Yes 2 0 1 Yes Yes Yes 2 2nd Floor 848 6784 No 2 2 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Floor over Garage Main ____ ____ 674 ft2 21 0.5 0.5 0 2 Raised Floor 2nd Floor __-_ 848 ft2 21 0.5 0.5 0 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Metal 1569 ft2 0 ft2 Unfinishe 0.96 Yes 0.7 Yes 0 14 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 1522 ft2 N Y 10/3/2014 7:12 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 6 CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic (Unvented) 2nd Floor 21 848 ft2 0.11 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below II Type Space R- lai o 1 W Exterior Concrete Block - Ext Insu2nd Floor 4 32 10 8 0 262.7 ft2 0 0 0.75 0 2 N Exterior Concrete Block - Ext Insu2nd Floor 4 12 4 8 0 98.7 ft2 0 0 0.76 0 3 E Exterior Frame - Wood 2nd Floor 19 3 9 8 30.0 ft2 19 0.23 0.75 0 4 E Exterior Concrete Block - Ext Insu2nd Floor 4 32 10 8 262.7 ft2 0 0 0.75 0 5 S Exterior Concrete Block - Ext Insu2nd Floor 11 24 9 8 198.0 ft2 0 0 0.75 0 6 E Exterior Concrete Block - Ext Insul Main 4 30 8 8 0 245.3 ft2 0 0 0.75 0 7 S Exterior Frame - Wood Main 11 12 0 12 3 147.0 ft2 11 0.23 0.75 0 8 E Exterior Frame - Wood Main 11 9 0 12 3 110.3 ft2 11 0.23 0.75 0 9 S Exterior Frame - Wood Main 11 3 10 12 3 47.0 ft2 11 0.23 0.75 0 10 E Exterior Frame - Wood Main 11 12 8 12 3 155.2 ft2 11 0.23 0.75 0 11 S Exterior Concrete Block - Ext Insul Main 4 4 6 12 3 55.1 ft2 0 0 0.75 0 12 W Exterior Concrete Block - Ext Insul Main 4 42 7 8 340.7 ft2 0 0 0.75 0 13 E Exterior Concrete Block - Ext Insul Main 4 23 3 8 186.0 ft2 0 0 0.75 0 14 N Exterior Frame - Wood Main 11 8 9 8 70.0 ft2 11 0.23 0.75 0 15 E Exterior Frame - Wood Main 11 10 6 8 84.0 ft2 11 0.23 0.75 0 16 S Exterior Frame - Wood Main 11 18 3 8 146.0 ft2 11 0.23 0.75 0 17 W Exterior Frame - Wood Main 11 25 8 200.0 ft2 11 0.23 0.75 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 W Wood Main Wood .46 3 6 8 20 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. V Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 W 1 Metal Double (Tinted) Yes 0.87 0.29 64.8 ft2 1 ft 0 in 0 ft 8 in Drapes/blinds None 2 W 1 Metal Double (Tinted) Yes 0.87 0.29 4.7 ft2 1 ft 0 in 0 ft 8 in Drapes/blinds None 3 N 2 Metal Double (Tinted) Yes 0.87 0.29 18.4 ft2 1 ft 3 in 0 ft 8 in Drapes/blinds None 4 E 3 Metal Double (Tinted) Yes 0.87 0.29 20.0 ft2 12 ft 3 in 0 ft 8 in Drapes/blinds None 5 E 4 Metal Double (Tinted) Yes 0.87 0.29 32.4 ft2 0 ft 6 in 0 ft 8 in Drapes/blinds None 6 E 4 Metal Double (Tinted) Yes 0.87 0.29 64.8 ft2 0 ft 6 in 0 ft 8 in Drapes/blinds None 7 S 5 Metal Double (Tinted) Yes 0.87 0.29 32.4 ft2 1 ft 0 in 0 ft 8 in Drapes/blinds None 8 S 5 Metal Double (Tinted) Yes 0.87 0.29 32.4 ft2 0 ft 6 in 0 ft 8 in Drapes/blinds None 9 E 6 Metal Double (Tinted) Yes 0.87 0.29 32.4 ft2 1 ft 0 in 0 ft 8 in Drapes/blinds None 10 E 6 Metal Double (Tinted) Yes 0.87 0.29 6.7 ft2 1 ft 0 in 0 ft 8 in Drapes/blinds None 11 E 6 Metal Double (Tinted) Yes 0.87 0.29 14.0 ft2 0 ft 6 in 10 It 5 in Drapes/blinds None 12 E 6 Metal Double (Tinted) Yes 0.87 0.29 36.8 ft2 0 ft 6 in 10 ft 5 in Drapes/blinds None 13 W 12 Metal Double (Tinted) Yes 0.87 0.29 36.8 ft2 1 ft 10 in 5 ft 0 in Drapes/blinds None 10/3/2014 7:12 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 6 WINDOWS Orientation shown is the entered, Proposed orientation. Wall V # Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Area Depth Separation - Int Shade Screening 14 E 15 N 13 Metal Double (Tinted) Yes 14 Metal Low-E Single Yes 0.87 0.29 46.4 ft2 1 ft 0 in 10 ft 5 in Drapes/blinds 0.87 0.29 40.0 ft2 7 ft 10 in 0 ft 8 in Drapes/blinds None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 810.16ft2 0ft2 115ft 12.2ft 0 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Best Guess .0003 1197.7 65.75 123.65 .2696 5.9018 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 15 37.6 kBtu/hr 1128 cfm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.92 66 gal 40 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ftZ DUCTS # — Supply — Location R-Value Area — Return — Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 Attic 6 164 ft2 Main 41 ftz Prop. Leak Free Main — cfm 45.7 cfm 0.03 0.60 1 1 10/3/2014 7:12 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 6 TEMPERATURES Programable Thermostat: Y Ceiling Fans: CoolingX Jan f Feb (X Mar r Ma Jun Jul Au Se Oct Nov X Dec HeatinX� JanX� Feb [X� Mar �JA Apr F j May JunX� JulX� K Aug K �js ep Occt �XNov Dec Venting [X Jan [X Feb [X] Mar Jun Jul Aug Sep t Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) PM 78 78 78 70 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MECHANICAL VENTILATION Type Supply CFM Exhaust CFM Fan Watts HRV Heating System Run Time Cooling System None 0 0 0 0 - 0% 1- Central Unit 10/3/2014 7:12 AM EnergyGaugeO USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 6 FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: 10701 S OCEAN DR. LOT 15 PERMIT #: JENSEN BCH., FL, 34957- MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed Iighting�IC-rated as meeting ASTM E 283. Windows and doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: gasketed doors & outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat & 403.1 At least one thermostat shall be provided for each separate heating and controls cooling system. Where forced -air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff (gas). Circulating system pipes insulated to = R-2 + accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower (HP) of = 1 & Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor -retardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from site -recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4/16113). Heat pump pool heaters minimum COP= 4.0. Cooling/heating 403.6 Sizing calculation performed & attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special equipment occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat >10kW must be divided into two or more stages. Ceilings/knee walls 405.2.1 R-19 space permitting. 1013/2014 7:12 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 6 of 6 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 79 The lower the EnergyPerformance Index, the more efficient the home. 10701 S OCEAN DR. LOT 15, JENSEN BCH., FL, 34957- 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Windows" Description a. U-Factor: Dbl, U=0.87 SHGC: SHGC=0.29 b. U-Factor: Sgl, U=0.87 SHGC: SHGC=0.29 c. U-Factor: N/A SHGC: d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth Area Weighted Average SHGC: 8. Floor Types a. Raised Floor b. Floor over Garage c. N/A New (From Plans) 9. Wall Types Insulation Area Single-family a. Concrete Block - Ext Insul, Exterior R=4.0 1451.10 ft2 b. Frame -Wood, Exterior R=11.0 959.38 ft2 1 c. Concrete Block - Ext Insul, Exterior R=11.0 198.00 ft2 2 d. other (see details) R= 30.00 ft2 10. Ceiling Types Insulation Area No a. Roof Deck (Unvented) R=0.0 848.00 ft2 1522 b. NIA R= ft2 Area c. NIA R= ft2 442.75 ft2 11. Ducts R ft2 a. Sup: Attic, Ret: Main, AH: Main 6 164 40.00 ft2 12. Cooling systems kBtu/hr Efficiency ft2 a. Central Unit 37.6 SEER:15.00 ft2 13. Heating systems kBtu/hr Efficiency a. Electric Strip Heat 28.0 COP:1.00 1.919 ft. 0.290 Insulation Area 14. Hot water systems Cap: 66 gallons R=21.0 848.00 ft2 a. Electric EF: 0.92 R=21.0 674.00 ft2 R= ft2 b. Conservation features None 15. Credits CF, WHF, Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software