HomeMy WebLinkAboutEnergy Efficiency CodeFORM 405-10
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
,-Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: MR AND MRS STROIK
Builder Name:
Street: 10701 S OCEAN DR. LOT 15
Permit Office: st. Iucie co. / ft. pierce
City, State, Zip: JENSEN BCH. , FL , 34957-
Permit Number:
Owner: SAME
Jurisdiction: 661100
Design Location: FL, Fort Pierce
1. New construction or existing New (From Plans)
9. Wall Types (2638.5 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.0 1451.10 ft'
b. Frame - Wood, Exterior
R=11.0 959.38 ft'
3. Number of units, if multiple family 1
c. Concrete Block - Ext Insul, Exterior
R=11.0 198.00 ft'
4. Number of Bedrooms 2
d. other (see details)
R= 30.00 ft'
10. Ceiling Types (848.0 sqft.)
Insulation Area
5. Is this a worst case? No
a. Roof Deck (Unvented)
R=0.0 848.00 ft:
6. Conditioned floor area above grade (ft') 1522
b. NIA
R= ft'
c. N/A
R= ft'
Conditioned floor area below grade (ft') 0
11. Ducts
R ft'
7. Windows(482.8 sqft.) Description Area
a. Sup: Attic, Ret: Main, AH: Main
6 164
a. U-Factor: Dbl, U=0.87 442.75 ft'
SHGC: SHGC=0.29
b. U-Factor: Sgl, U=0.87 40.00 ft'
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.29
a. Central Unit
37.6 SEER:15.00
C.. U-Factor: N/A ft'
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft'
a. Electric Strip Heat
28.0 COPA.00
SHGC:
Area Weighted Average Overhang Depth: 1.919 ft.
Area Weighted Average SHGC: 0.290
14. Hot water systems
a. Electric
Cap: 66 gallons
8. Floor Types (1522.0 sqft.) Insulation Area
EF: 0.920
a. Raised Floor R=21.0 848.00 ft'
b. Conservation features
b. Floor over Garage R=21.0 674.00 ft'
None
c. NIA R= ft2
15. Credits
CF, WHF, Pstat
Glass/Floor Area: 0.317 Total Proposed Modified Loads: 36.77
PASS
Total Standard Reference Loads: 46.74
1 hereby certify that the plans and specifications covered by
Review of the plans and
F'TKE SrAT
this calculation are in compliance with the Florida Energy
specifications covered by this
-4V
Code.
calculation indicates compliance
y�a„ '' ,-,�''���•�`�� ��.
with the Florida Energy Code.10
•+n+++'!• ;;,'� a
PREPARED y:
Before construction is completed
--
DATE:
this building will be inspected for
-
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
✓,� ��
COD
with the Florida Energy Code.
W6'C��
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with 403.2.2.1.1.
- Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist
- Compliance requires a roof absorptance test and a roof emittance test in accordance with 405.6.2
- Compliance .requires an air distribution system test report, by a Florida Class 1 Rater, confirming system
leakage to'outdoors tested at 25 pascals pressure difference in accordance with 403.2.2.1. is not greater than
(46 cfm:Duct#1)
AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 6
PROJECT
Title:
MR AND MRS STROIK Bedrooms: 2
Address Type:
Street Address
BUilding Type:
User
Conditioned Area: 1522
Lot #
10
Owner:
SAME
Total Stories: 2
Block/SubDivision:
# of Unt�.,:
1
Worst Case: No
PlatBook:
Builder Name:
Rotate Angle: 0
Street:
10701 S OCEAN DR. L
Permit Office:
st. lucie co. / ft. pierce
Cross Ventilation: No
County:
st. lucie
Jurisdiction:
661100
Whole House Fan: Yes
City, State, Zip:
JENSEN BCH. ,
Family Type:
Single-family
FL, 34957-
New/Existing:
New (From Plans)
Comment:
CLIMATE
V
IECC Design Temp
Int Design Temp Heating
Design Daily Temp
Design Location
TMY Site Zone 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_ST_LUCIE CO INTL 2 39 90
70
75 722
62
Low
BLOCKS
Number
Name
Area Volume
1
Blockl
1522 12176
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled
Heated
1
Main
674 5392 Yes 2
0
1 Yes
Yes
Yes
2
2nd Floor
848 6784 No 2
2
1 Yes
Yes
Yes
FLOORS
#
Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Floor over Garage
Main ____ ____
674 ft2
21
0.5 0.5
0
2 Raised Floor
2nd Floor __-_
848 ft2
21
0.5 0.5
0
ROOF
Roof Gable Roof
Solar
SA Emitt
Emitt Deck
Pitch
#
Type
Materials Area Area Color
Absor.
Tested
Tested Insul.
(deg)
1
Hip
Metal 1569 ft2 0 ft2 Unfinishe
0.96
Yes 0.7
Yes 0
14
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Unvented 0 1522 ft2
N Y
10/3/2014 7:12 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 6
CEILING
#
Ceiling Type
Space
R-Value
Area
Framing Frac
Truss Type
1
Under Attic (Unvented)
2nd Floor
21
848 ft2
0.11
Wood
WALLS
Adjacent
Cavity
Width
Height
Sheathing Framing Solar
Below
II Type
Space
R- lai
o
1
W
Exterior
Concrete Block - Ext Insu2nd Floor
4
32
10
8
0
262.7 ft2
0
0 0.75
0
2
N
Exterior
Concrete Block - Ext Insu2nd Floor
4
12
4
8
0
98.7 ft2
0
0 0.76
0
3
E
Exterior
Frame - Wood
2nd Floor
19
3
9
8
30.0 ft2
19
0.23 0.75
0
4
E
Exterior
Concrete Block - Ext Insu2nd Floor
4
32
10
8
262.7 ft2
0
0 0.75
0
5
S
Exterior
Concrete Block - Ext Insu2nd Floor
11
24
9
8
198.0 ft2
0
0 0.75
0
6
E
Exterior
Concrete Block - Ext Insul Main
4
30
8
8
0
245.3 ft2
0
0 0.75
0
7
S
Exterior
Frame - Wood
Main
11
12
0
12
3
147.0 ft2
11
0.23 0.75
0
8
E
Exterior
Frame - Wood
Main
11
9
0
12
3
110.3 ft2
11
0.23 0.75
0
9
S
Exterior
Frame - Wood
Main
11
3
10
12
3
47.0 ft2
11
0.23 0.75
0
10
E
Exterior
Frame - Wood
Main
11
12
8
12
3
155.2 ft2
11
0.23 0.75
0
11
S
Exterior
Concrete Block - Ext Insul Main
4
4
6
12
3
55.1 ft2
0
0 0.75
0
12
W
Exterior
Concrete Block - Ext Insul Main
4
42
7
8
340.7 ft2
0
0 0.75
0
13
E
Exterior
Concrete Block - Ext Insul Main
4
23
3
8
186.0 ft2
0
0 0.75
0
14
N
Exterior
Frame - Wood
Main
11
8
9
8
70.0 ft2
11
0.23 0.75
0
15
E
Exterior
Frame - Wood
Main
11
10
6
8
84.0 ft2
11
0.23 0.75
0
16
S
Exterior
Frame - Wood
Main
11
18
3
8
146.0 ft2
11
0.23 0.75
0
17
W
Exterior
Frame - Wood
Main
11
25
8
200.0 ft2
11
0.23 0.75
0
DOORS
#
Ornt
Door Type
Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
W
Wood
Main
Wood
.46
3
6 8
20 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
V
Wall
Overhang
#
Ornt ID
Frame Panes
NFRC
U-Factor SHGC
Area
Depth
Separation
Int Shade
Screening
1
W 1
Metal Double (Tinted)
Yes
0.87
0.29
64.8 ft2
1 ft 0 in
0 ft 8 in
Drapes/blinds
None
2
W 1
Metal Double (Tinted)
Yes
0.87
0.29
4.7 ft2
1 ft 0 in
0 ft 8 in
Drapes/blinds
None
3
N 2
Metal Double (Tinted)
Yes
0.87
0.29
18.4 ft2
1 ft 3 in
0 ft 8 in
Drapes/blinds
None
4
E 3
Metal Double (Tinted)
Yes
0.87
0.29
20.0 ft2
12 ft 3 in
0 ft 8 in
Drapes/blinds
None
5
E 4
Metal Double (Tinted)
Yes
0.87
0.29
32.4 ft2
0 ft 6 in
0 ft 8 in
Drapes/blinds
None
6
E 4
Metal Double (Tinted)
Yes
0.87
0.29
64.8 ft2
0 ft 6 in
0 ft 8 in
Drapes/blinds
None
7
S 5
Metal Double (Tinted)
Yes
0.87
0.29
32.4 ft2
1 ft 0 in
0 ft 8 in
Drapes/blinds
None
8
S 5
Metal Double (Tinted)
Yes
0.87
0.29
32.4 ft2
0 ft 6 in
0 ft 8 in
Drapes/blinds
None
9
E 6
Metal Double (Tinted)
Yes
0.87
0.29
32.4 ft2
1 ft 0 in
0 ft 8 in
Drapes/blinds
None
10
E 6
Metal Double (Tinted)
Yes
0.87
0.29
6.7 ft2
1 ft 0 in
0 ft 8 in
Drapes/blinds
None
11
E 6
Metal Double (Tinted)
Yes
0.87
0.29
14.0 ft2
0 ft 6 in
10 It 5 in
Drapes/blinds
None
12
E 6
Metal Double (Tinted)
Yes
0.87
0.29
36.8 ft2
0 ft 6 in
10 ft 5 in
Drapes/blinds
None
13
W 12
Metal Double (Tinted)
Yes
0.87
0.29
36.8 ft2
1 ft 10 in
5 ft 0 in
Drapes/blinds
None
10/3/2014 7:12 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 6
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
V # Ornt ID Frame Panes
NFRC
Overhang
U-Factor SHGC Area Depth Separation - Int Shade
Screening
14 E
15 N
13 Metal Double (Tinted) Yes
14 Metal Low-E Single Yes
0.87 0.29 46.4 ft2 1 ft 0 in 10 ft 5 in Drapes/blinds
0.87 0.29 40.0 ft2 7 ft 10 in 0 ft 8 in Drapes/blinds
None
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
810.16ft2
0ft2
115ft 12.2ft 0
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse
Best Guess
.0003
1197.7 65.75 123.65 .2696 5.9018
COOLING SYSTEM
# System Type
Subtype
Efficiency Capacity Air Flow SHR Block
Ducts
1 Central Unit
Split
SEER: 15 37.6 kBtu/hr 1128 cfm 0.7 1
sys#1
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt Conservation
1
Electric None
Garage
0.92 66 gal 40 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Cert #
Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None
None
ftZ
DUCTS
#
— Supply —
Location R-Value Area
— Return — Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT QN RLF
HVAC #
Heat Cool
1
Attic 6 164 ft2
Main
41 ftz Prop. Leak Free Main — cfm 45.7 cfm 0.03 0.60
1 1
10/3/2014 7:12 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 6
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
CoolingX Jan
f
Feb
(X Mar
r
Ma
Jun
Jul
Au
Se
Oct
Nov
X Dec
HeatinX� JanX�
Feb
[X� Mar
�JA
Apr
F j May
JunX�
JulX�
K
Aug
K
�js
ep
Occt
�XNov
Dec
Venting [X Jan
[X Feb
[X] Mar
Jun
Jul
Aug
Sep
t
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
PM
78
78
78
70
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
MECHANICAL VENTILATION
Type
Supply CFM
Exhaust CFM Fan Watts
HRV
Heating System
Run Time Cooling System
None
0
0
0
0
-
0%
1- Central Unit
10/3/2014 7:12 AM EnergyGaugeO USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 6
FORM 405-10
Florida Code Compliance Checklist
Florida Department of Business and Professional Regulations
Residential Whole Building Performance Method
ADDRESS: 10701 S OCEAN DR. LOT 15 PERMIT #:
JENSEN BCH., FL, 34957-
MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details.
COMPONENT
SECTION
SUMMARY OF REQUIREMENT(S)
CHECK
Air leakage
402.4
To be caulked, gasketed, weatherstripped or otherwise sealed.
Recessed Iighting�IC-rated as meeting ASTM E 283. Windows and
doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces:
gasketed doors & outdoor combustion air. Must complete envelope
leakage report or visually verify Table 402.4.2.
Thermostat &
403.1
At least one thermostat shall be provided for each separate heating and
controls
cooling system. Where forced -air furnace is primary system,
programmable thermostat is required. Heat pumps with supplemental
electric heat must prevent supplemental heat when compressor can
meet the load.
Ducts
403.2.2
All ducts, air handlers, filter boxes and building cavities which form the
primary air containment passageways for air distribution systems shall
be considered ducts or plenum chambers, shall be constructed and
sealed in accordance with Section 503.2.7.2 of this code.
403.3.3
Building framing cavities shall not be used as supply ducts.
Water heaters
403.4
Heat trap required for vertical pipe risers. Comply with efficiencies in
Table 403.4.3.2. Provide switch or clearly marked circuit breaker
(electric) or shutoff (gas). Circulating system pipes insulated to = R-2
+ accessible manual OFF switch.
Mechanical
403.5
Homes designed to operate at positive pressure or with mechanical
ventilation
ventilation systems shall not exceed the minimum ASHRAE 62 level.
No make-up air from attics, crawlspaces, garages or outdoors adjacent
to pools or spas.
Swimming Pools
403.9
Pool pumps and pool pump motors with a total horsepower (HP) of = 1
& Spas
HP shall have the capability of operating at two or more speeds. Spas
and heated pools must have vapor -retardant covers or a liquid cover or
other means proven to reduce heat loss except if 70% of heat from
site -recovered energy. Off/timer switch required. Gas heaters minimum
thermal efficiency=78% (82% after 4/16113). Heat pump pool heaters
minimum COP= 4.0.
Cooling/heating
403.6
Sizing calculation performed & attached. Minimum efficiencies per
Tables 503.2.3. Equipment efficiency verification required. Special
equipment
occasion cooling or heating capacity requires separate system or
variable capacity system. Electric heat >10kW must be divided into two
or more stages.
Ceilings/knee walls
405.2.1
R-19 space permitting.
1013/2014 7:12 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 6 of 6
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 79
The lower the EnergyPerformance Index, the more efficient the home.
10701 S OCEAN DR. LOT 15, JENSEN BCH., FL, 34957-
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
7. Windows" Description
a. U-Factor: Dbl, U=0.87
SHGC: SHGC=0.29
b. U-Factor: Sgl, U=0.87
SHGC: SHGC=0.29
c. U-Factor: N/A
SHGC:
d. U-Factor: N/A
SHGC:
Area Weighted Average Overhang Depth
Area Weighted Average SHGC:
8. Floor Types
a. Raised Floor
b. Floor over Garage
c. N/A
New (From Plans)
9. Wall Types
Insulation
Area
Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.0
1451.10 ft2
b. Frame -Wood, Exterior
R=11.0
959.38 ft2
1
c. Concrete Block - Ext Insul, Exterior
R=11.0
198.00 ft2
2
d. other (see details)
R=
30.00 ft2
10. Ceiling Types
Insulation
Area
No
a. Roof Deck (Unvented)
R=0.0
848.00 ft2
1522
b. NIA
R=
ft2
Area
c. NIA
R=
ft2
442.75 ft2
11. Ducts
R ft2
a. Sup: Attic, Ret: Main, AH: Main
6 164
40.00 ft2
12. Cooling systems
kBtu/hr
Efficiency
ft2
a. Central Unit
37.6 SEER:15.00
ft2
13. Heating systems
kBtu/hr
Efficiency
a. Electric Strip Heat
28.0
COP:1.00
1.919 ft.
0.290
Insulation
Area
14. Hot water systems
Cap:
66 gallons
R=21.0
848.00 ft2
a. Electric
EF: 0.92
R=21.0
674.00 ft2
R=
ft2
b. Conservation features
None
15. Credits
CF,
WHF, Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature:
Address of New Home:
Date:
City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software