Loading...
HomeMy WebLinkAboutTrussA-1 ROOF TRUSSES A FLORIDA CORPORATION Lumber design valt es are accordance with ANSI/TPI 1-2007 section 6.3 ely Il These truss designs rumber values established by others. RE: Job 59941 A-1 Roof Trusses 4451 St Lucie Blvd Site Information: Fort Pierce, FL 34946 Customer Info: L&C CONSTRUCTION INC. Project Name: STROIK JOB Lot/Block: Model: STROIK JOB Address: HOLIDAY OUT, JENSEN BEACH, FL Subdivision: City: County: St Lucie State: FL Name Address and License # of Structural Engineer of Record, If there is one, for the building. Name: License #: Address: City: General Truss Engineering Criteria Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC2010/TP12007 Design Program: MiTek 20/20 7.6 Wind Code: ASCE 7-10 Wind Speed:170 MPH Roof Load: 55.0 psf Floor Load: 55.0 psf This package includes 70 individual, dated Truss Design Drawings and 0 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61 G15-31.003,section 5 of the Florida Board of Professional Engineers Rules. No. Seal # Truss Name Date No. Seal # Truss Name Date No. Seal # Truss Name Date 1 A0134342 FG01 11/7114 13 A0134354 FL05 1117114 25 A0134366 FL30 11/7114 2 A0134343 FG02 1117/14 14 A0134355 FL06 1117114 26 A0134367 FL31 11R114 3 A0134344 FG03 1117/14 15 A0134356 FL07 1117114 27 A0134368 FL32 1IM14 4 A0134345 FG21 11/1114 16 A0134357 FL21G 11/7/14 28 A0134369 FL33 1117114 5 A0134346 FG22 1117114 17 A0134358 FL22 1117114 29 A0134370 FL34 1117114 6 A0134347 FG23 11/7/14 18 A0134359 FL23 1117114 30 A0134371 FL35 1117114 7 A0134348 FG24 1117/14 19 A0134360 FL24 11/7/14 31 A0134372 FL36 11/7/14 8 A0134349 FG25 1117114 20 A0134361 FL25 11M14 32 A0134373 FL37 1IM14 9 A0134350 FL01 1117114 21 A0134362 FL26 1117114 33 A0134374 FL38 11/7114 10 A0134351 FL02 11/7/14 22 A0134363 FL27 11/7/14 34 A0134323 A01G 11/7114 11 A0134352 FL03 1117114 23 A0134364 FL28 1117/14 35 A0134324 A02 11f7114 12 A0134353 FL04 1IM14 24 A0134365 FL29 11/7/14 36 A0134325 A03 11R/14 The truss drawing(s) referenced have been prepared by MiTek Industries, Inc. under my direct supervision based on the parameters provided byA-1 Roof Trusses, Ltd. Truss Design Engineer's Name: Julius Lee. My license renewal date for the state of Florida is February 28,2015. NOTE: The seal on these drawings indicate acceptance of professional engineering responsibility solely for the truss components shown. The suitability and use of components for any particular building is the responsibility of the building designer, per ANSI TPI-1 Sec. 2. \\1111111111//� ws.s.k.<''�, Digitally signed by Julius Lee �GENS'* DN: c=US, st=Florida,l=Boynton N 34869 ABeach, o=Julius Lee, cn=Julius - � LU '01STATE OF \_�� Ji��\ee e:rnail=leeengr@aol.com i FCORIDP` s/oNA`1���' Date: 2014.11.07 11:27:33-05'00' /111111 Page 1 of 2 A-1 ROOF TRUSSES A FLORIDA CORPORATION RE: Job 59941 No. Seal # Truss Name Date 37 A0134326 A04 11I7114 38 A0134327 A05 1117114 39 A0134328 A06 1117/14 40 A0134329 A07G 1117114 41 A0134330 B01 G 1117114 42 A0134331 B02G 11R114 43 A0134332 C01 G 1117114 44 A0134333 CO2 1117114 45 A0134334 CO3 11n/14 46 A0134335 C04 1117114 47 A0134336 CJA 1117/14 48 A0134337 CJAA 1117/14 49 A0134338 D01G 11/7/14 50 A0134339 D02 11/7114 51 A0134340 D03 1117/14 52 A0134341 D04 1117/14 53 A0134375 HJA 1117114 54 A0134376 HJAA 117/14 55 A0134377 JA 11/7114 56 A0134318 JAA 1IM14 57 A0134379 JB 1117114 58 A0134380 JBA 1117/14 59 A0134381 JC 1117114 60 A0134382 JCA 11/7/14 61 A0134383 JD 1117/14 62 A0134384 JDA 1117114 63 A0134385 JE 11/7/14 64 A0134386 JEA 1117/14 65 A0134387 JF 1117/14 66 A0134388 JFA 11/7/14 67 A0134389 JG 1117/14 68 A0134390 JGA 1117/14 69 A0134391 JH 1117114 70 A0134392 JHA 1117/14 Lumber design values ard($ accordance with ANSI/TPI 1-2007 section 6.3 These truss designs rely can lumber values established by others. I Page 2of2 Job Truss Truss Type 4 J, Qty Ply 59941 A01G Roof Special Girder 1 A0134323 Job Reference (optional) Al ROOF TRUSSES, FORT PIERCE, FL 34946 7.600 s Oct 3 2014 MiTek Industries, Inc. Fri Nov 07 09:12:03 2014. Page 1 ID:nTgtNvPNwyOwNLlv4xWHRyyM D8g-b3iBtm2ASQ4XblkEnnZR70yh F?h WwAPsfF7PvFyLdt/ 0-10.2 0-0-1 0- 6.2-5 10-5-6 14-6-9 1 16-7-s 22-z-13 1 5-0-4 4-3-1 4-1-2 2-1-0 5-7-4 0-0-1 0-10-1 Dead Load Defl. = 5116 in 4.00 3 C. 4x4 = 9 nn 13 1.5x4 11 7x6 = _ 3x4 = 0.50 12 1.00112 1-3-5 8-14 6-2-5 10-5-6 14-9-10 16.7-9 22-2-13 14 4-11-1 43-1 4-4.4 1-9-15 5-7-4 I6 Plate Offsets (X 1)--[2'0-3-0 0-2-71 [2:0-4-6 Edoel r9:0-2-4 0-2-81 r11:0-3-0 0-3-41 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.62 Vert(LL) 0.30 11-12 >851 360 MT20 244/190 TCDL 15.0 Lumber DOL 1 1.25 BC 0.85 Vert(TL)-0.6211-12 >407 240 BCLL 0.0 ' Rep Stress Incr NO WB 0.35 Horz(TL) 0.13 7 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) Weight: 280 lb FT = 0% LUMBER - TOP CHORD 2x4 SP M 30'Except' T1: 2x4 SP No.2 BOT CHORD 2x4 SP M 30 *Except' 63: 2x6 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 cc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. All bearings 0-6-8 except Qt=length) 7=0-8-0. (lb) - Max Horz 1= 61(LC 27) Max Uplift All uplift 100 lb or less at joint(s) except 7=-816(LC 5), 1=-1262(LC 4), 13=-1169(LC 1) Max Grav All reactions 250 lb or less at joint(s) except7=2085(LC 1.), 1=2692(LC 1), 13=495(LC 4), 1=2892(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-7408/3045, 2-21=7481/3069, 21-22=-7440/3080, 3-22=7424/3082, 3-23=-8179/3336, 4-23=-8141 /3332, 4-24=-6260/2536, 5-24=-620612522, 5-6=-6642/2691,6-7=-6736/2621 BOT CHORD 1-17=-3016/7314, 1-13=-301617314, 13-25=-301417308,25-26=-3014/7308, 12-26=-301317311,12-27=-3023/7326, 11-27=-3021/7330,11-28=-3255/8060, 10-28=-3251/8065, 9-10=2247/5831, 8-9=-2418/6339, 7-8=-2412/6323 WEBS 5-1 0=-1 068/2759, 4-10=-2049/903, 4-11=0/276, 3-11=-301/845, 3-12=357/236, 6-9=-456/437 NOTES- 1) Special connection required to distribute web loads equally between all plies. 2) 3-ply truss to be connected together as follows: Top chords connected with 10d (0.131 "x3") nails as follows: 2x4 - 2 rows staggered at 04-0 oc. Bottom chords connected with 1 Od (0.131 "x3") nails as follows: 2x4 - 2 rows staggered at 0-4-0 oc, 2x6 - 3 rows staggered at 04-0 oc. Web connected with 12 Gauge (0.216"x&V5 screws as follows: 2x4 - 1 row at 0-9-0 cc. 3) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 4)' Unbalanced roof live loads have been considered for this design. 5) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=28ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed ; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 6) Plates checked for a plus or minus 0 degree rotation about its center. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Bearing at joint(s) 7 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 816 lb uplift at joint 7,.1262lb uplift at joint 1, 1169 lb uplift at joint 13 and 1262 lb uplift at joint 1. 11) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 12) This truss has large uplift reaction(s) from gravity load case(s). Proper connection is' required to secure truss against upward movement at the bearings. Building designer must provide for uplift reactions indicated. 13) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 53 lb down and 74 lb up at 2-5-12, 72 lb down and 69 lb up at 4-5-12, 88 lb down and 95 lb up at 6-5-12, 128 lb down and 120 lb up at 8-5-12, and 168 lb down and 146 lb up at 10-5-12, and 208 lb down and 173 lb up at 12-5-12 on top chord, and 33 lb up at 2-5-12, 4 lb down and 13 lb up at 4-5-12, 16 lb down and 7 lb up at 6-5-12, 35 lb down and 1 lb up at 8-5-12, 58 lb down at 10-5-12, and 81 lb down at 12-5-12, and 1021 lb down and 464 lb up at 14-5-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber-lncrease=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-2=-90, 2-5=-90, 5-7=-90, 13-17=20, 9-13=-20, 9-14=-20 Concentrated Loads (lb) Vert: 11=-29(B) 10=-1021(B) 4=-108(B) 3=-28(B) 12=-6(B) 21=74(B) 22=13(B) 23=-68(B) 24=-148(B) 25=17(B) 26=6(B) 27=17(B) 28=-41(B) Julius Lee, P-E. M34869 — 1109 Coastal Bay — Boynton Beach, FL 33435 Job Truss Truss Type ` y \ Ply 59941 A02 Roof Special �Qty 1 1 A0134324 Job Reference (optional) Al ROOF TRUSSES, FORT PIERCE, FL 34946 7.600 s Oct 3 2014 MiTek Industries, Inc. Fri Nov 07 09:12:04 2014 Page 1 ID:nTgtNvPNwyOwNLlv4xWHRyyMD8g-3FGa463oDkCODvJRLU4ggcUg8P21 fZl7tvszRhyLdtE ao•1 0.p•01-4-13 , 43-11 , 8�-5 13-4-11 16-9.9 i 22-2-13 , 0. 11-4-12 2-1a14 4-2-10 416.6 3-4-14 5-54' aa1 2.00 F12 4x4 = Dead Load Defl. = 5116 in 3x4 = 4.00 Fl2 5x6 3 3x4 ZZ 5 2 1 6 ` • 9 5x8 = 1.5x4 11 f 10 3x4 = 7 f ` 11' 5x6 = 4x4 0.50 12 M= 1.00 12 3xl2 MT20HS= 1-4-13 LOADING(psf) SPACING- 2-0-0 TCLL 30.0 Plate Grip DOL 1.25 TCDL 15.0 Lumber DOL 1.25 BCLL 0.0 * Rep Stress Incr YES BCDL 10.0 Code FBC2010/TPI2007 LUMBER - TOP CHORD 2x4 SP No.2 *Except* T1: 2x4 SP M 30 BOT CHORD 2x4 SP M 30 *Except* B3,B4: 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 2-6-9 oc purlins. BOT CHORD Rigid ceiling directly applied or 3-10-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in . accordance with Stabilizer Installation auide. REACTIONS. All bearings 0-8-0. (lb) - Max Horz 1= 69(LC 12) Max Uplift All uplift 100 lb or less at joint(s) 11 except 6=-390(LC 9), 1=450(LC 8) Max Grav All reactions 250 lb or less at . joint(s) except 6=1189(LC 1), 1=1006(LC 1), 11=251(LC 1), 1=1006(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-3183/2108,2-3=-3804/2560, 3-4=-2865/1956,4-5=-3177/2138, 5-6=-3754/2482 BOT CHORD 1-15=-1870/2897,1-11=-1870/2897, 10-11=-1870/2898, 9-1 0=1 862/2906, 8-9=-2352/3700, 7-8=-2247/3491, 6-7=-2246/3487 WEBS 4-8=-659/1075, 5-8=-625/492, 2-9=-505/818, 3-8=-1022/712 NOTES- 1) Unbalanced roof live loads have been considered for this design. CSI. DEFL. in (loc) I/defl L/d TC 0.74 Vert(LL) 0.30 8-9 >845 360 BC 0.83 Vert(TL) -0.59 8-9 >420 240 WB 0.57 Horz(TL) 0.20 6 n/a n/a (Matrix-M) 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=28ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) Plate(s) at joint(s) 2, 6, 1, 11, 8, 4, 5, 7, 9 and 3 checked for a plus or minus 0 degree rotation about its center. 5) Plate(s) at joint(s) 10 checked for a plus or minus 3 degree rotation about its center. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where, a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Bearing at joint(s) 6 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11 except at --lb) 6=390, 1=450, 1=450. 10) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard PLATES GRIP MT20 244/190 MT20HS 187/143 Weight: 94 lb FT = 0% Julius Lee, P.E. 0#34869 — 1109 Coastal Bay — Boynton Beach, FL 33435 Job Truss Truss Type T ;� Qty Ply A0134325 59941 A03 Roof Special 1 1 Job Reference (optional) Al. ROOF IKUSStS, FOR F'ItKGt, FL3454ti 7.600 s Oct 3 2014 MiTek Industries, Inc. Fri Nov 07 09:12:04 2014 Page 1 ID:nTgtNvPNwyOwNLlv4xWHRyyM D8g-3FGa463oD kCODvJRLU4ggcUrZP?xfd8?tvszRhyLdt< 0.0.1 0. 01-4-13 6-3-11 7-9-4 12-2-13 16-&6 22-2-13 0. 11-4-12 4-10-14 1-5-9 4-5-9 45-9 5-6-7 2.00 12 4x4 = 5x6 Dead Load Defl. = 5/16 in 11 5x6 = 0.50 12 4x4 3x6 = 4x4 = 1.00 12 1-4-13 8-1 4-8-5 7-11-14 12-7-13 17-0-2 22-2-13 8-1 3-3-8 3-3-8 4-7-15 4-4-5 5-2-11 o-6-0 Plate Offsets (x Y)--[3'0-1-4 0-2-81 [4:0-2-0 0-0-81 [6:0-3-8 Edgel [8:0-2-12 0-2-121 r9:0-1-12 0-2-81 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.65 Vert(LL) 0.25 7-8 >986 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.96 Vert(TL) -0.51 8-9 >486 240 BCLL 0.0 Rep Stress Incr YES WB - 0.32 Horz(TL) 0.20 6 n/a n/a BCDL 10.0 Code FBC201 O/TPI2007 (Matrix-M) Weight: 94 lb FT = 0% LUMBER - TOP CHORD 2x4 SP No.2 *Except* T1: 2x4 SP M 30 SOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 2-9-2 oc purlins. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation auide. REACTIONS. All bearings 0-8-0. (lb) - Max Horz 1= 78(LC 12) Max Uplift All uplift 100 lb or less at joint(s) 11 except 6=-409(LC 9), 1=-539(LC 8) Max Grav All reactions 250 lb or less at joint(s) 11 except 6=1198(LC 1), 1=1320(LC 1), 1=1320(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-3294/2153,2-3=-3141/2143, 3-4=-2708/1862,4-5=-2984/1993, 5-6=-3827/2526 BOT CHORD 1-15=-1894/2996, 1-11=-1894/2996, 10-11 =-1 899/3005, 9-1 0=1 907/3015, 8-9=-1821/2963, 7-8=-2292/3563, 6-7=-2290/3560 WEBS 3-9=-214/347, 3-8=-529/303, 4-8=-539/923, 5-8=-867/687 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE.7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=28ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Extedor(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) The solid section of the plate is required to be placed over the splice line at joint(s) 11. 4) Plate(s) at joint(s) 3,-6, 1, 8, 2, 10, 9, 4, 5 and 7 checked for a plus or minus 0 degree rotation about its center. 5) Plate(s) at joint(s) 11 checked for a plus or minus 4 degree rotation about its center. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7)' This1russ has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Bearing at joint(s) 6 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 11 except at --lb) 6=409, 1=539, 1=539. 10) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Julius Lee, P.E- #34869— 1109 Coastal -Bay — Boynton Beach, FL 33435 Job Truss Truss Type T Qty Ply A0134326 59941 �A!34 Scissor 1 1 Job Reference optional Al ROOF TRUSSES, FORT PIERCE, FL 34946 7.600 s Oct 3 2014 MiTek Industries, Inc. Fri Nov 07 09:12:05 2014 Page 1 ID:nTgtNvPNwyOwNLlv4xWHRyyMD8g-XRgyIS4Q_2LFg3udvCbvDp 119pMWO?s96ZcWz7yLdtt 1-4-13 0-0.1 0 6-3-11 11-1-7 1641-10 22-2-13 1 4-10.14 4-9-12 5-7-3 5-6-3 0-0-1 4x4 = 1-4-12 Dead Load Defl. = 5/16 in a V 1.5x4 11 4x4 3x6 = 44 = 1.00 F12 1-4-13 -8.1 6.5.5 11-5-13 16.5.2 22-2-13 1 5-0.8 5.0.8 4-11-5 5-9.11 n.a.n Plate Offsets (X,Y)--13:0-2-0,0-2-41 15:0-3-8,Edgel LOADING(psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.59 Vert(LL) 0.26 7-8 >950 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.94 Vert(rL) -0.54 7-8 >465 240 BCLL 0.0 Rep Stress Incr YES WB 0.61 Horz(TL) 0.20 5 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight: 91 lb FT = 0% LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 3-5-5 oc purlins. BOT CHORD Rigid ceiling directly applied or 3-9-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation quide. REACTIONS. All bearings 0-8-0. (lb) - Max Horz 1= 87(LC 12) Max Uplift All uplift 100 lb or less at joint(s) except 5=-429(LC 9), 1=-553(LC 8), 9=-178(LC 1) Max Gray All reactions 250 lb or less at joint(s) 9 except 5=1202(LC 1), 1=1422(LC 1), 1=1422(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-3426/2234,2-3=-2620/1765, 3-4=-2781/1846,4-5=-3891/2570 BOT CHORD 1-13=-1975/3128, 1-9=-1975/3128, 8-9=-1981/3139,7-8=-1986/3146, 6-7=-2339/3629, 5-6=-2336/3624 WEBS 2-7=-797/618, 3-7=-674/1131, 4-7=-1129/884 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=28ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) The solid section of the plate is required to be placed over the splice line at joint(s) 9, 7. 4) Plate(s) at joint(s) 3, 5, 1, 2, 8, 4 and 6 checked for a plus or minus 0 degree rotation about its center. 5) Plate(s) at joint(s) 9 checked for a plus or minus 4 degree rotation about its center. 6) Plate(s) at joint(s) 7 checked for a plus or minus 3 degree rotation about its center. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Bearing at joint(s) 5 considers parallel to grain value using ANSI/fPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 429 lb uplift at joint 5, 553 lb uplift at joint 1, 178 lb uplift at joint 9 and 553 lb uplift at joint 1. 11) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Julius Lee, P.E. #34869— 1109 Coastal Bay — Boynton Beach, FL 33435 Job Truss Truss Type T Qty Ply A0134327 59941 A05 Roof Special 1 1 Job Reference (optional) Al ROOF TRUSSES, FORT PIERCE, FL 34946 7.600 s Oct 3 2014 MiTek Industries, Inc. Fri Nov 07 09:12:05 2014 Page 1 I D: nTg tNvPNwyOwN Llv4xW H RyyM D 8 g-XRgyl S4Q_2 LFg3udvCbvD p 10_pLB04Y96ZcWz7yLdt1 1-4-13 0-0-1 A 6-3.2 10-2-15 13-8-14 14-11-12 16•&11 22-2-13 1 4-10.5 3.11A 3-5-11 1-2-14 1-8-15 5.6.2 inn 1-4-12 4x4 = A n rl—n- 3 4x4= Dead Load Defl. = 5/16 in I6 11 1.5x4 II 0.50 12 44 3x6 = 4x4 = 1.00 12 1-4-13 8-1 6-3.2 10-3-13 13-8-14 14-11-12 16.8.11 22-2-13 8-1 4-10.5 4-0-11 3-5-0 1-2-14 1-a-15 5-62 0.8-0 Plate Offsets (X Y)--[6:0-3-8 Edoel [8'0-3-0 0-2-121 [9:0-4-12 0-2-81 LOADING(psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.67 Vert(LL) 0.26 9-10 >975 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.96 Vert(TL) -0.51 9-10 >492 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.31 Horz(TL) 0.19 6 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) Weight: 94 lb FT = 0% LUMBER - TOP CHORD 2x4 SP No.2 *Except* T1: 2x4 SP M 30 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 2-8-7 oc purlins. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation quide. REACTIONS. All bearings 0-8-0. (lb) - Max Horz 1= 80(LC 12) Max Uplift All uplift 100 lb or less at joint(s) except 6=-436(LC 9), 1=-526(LC 8), 11=-147(LC 1) Max Grav All reactions 250 lb or less at joint(s) 11 except 6=1 202(LC 1), 1=1391(LC 1), 1=1391(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-3386/2214, 2-3=-2769/1872, 3-4=-2684/1847,4-5=-3439/2322, 5-6=-3807/2512 BOT CHORD 1-1 5=-1 954/3088, 1-11=-1954/3088, 10-11=-196013098, 9-1 0=1 965/3105, 8-9=-1778/2876, 7-8=-2275/3540, 6-7=-2274/3537 WEBS 2-9=-618/490, 3-9=-550/898, 4-9=-452/318, 4-8=-382/615, 5-8=-453/387 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=28ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) The solid section of the plate is required to be placed over the splice line at joint(s) 11. 4) Plate(s) atjoint(s) 3, 4, 6, 1, 9, 8, 2, 10, 7 and 5 checked for a plus or minus 0 degree rotation about its center. 5) Plate(s) at joint(s) 11 checked for a plus or minus 4 degree rotation about its center. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Bearing at joint(s) 6 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 436 lb uplift at joint 6, 526 lb uplift at joint 1, 147 lb uplift at joint 11 and 526 lb uplift at joint 1. 10) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Julius Lee. P-E. #34869 — 1109 Coastal Bay — Boynton Beach, FL 33435 Job Truss Truss Type 4 T Oty Ply 59941 A06 � Roof Special 1 1 A013432$ Job Reference (optional) Al ROOF TRUSSES, FORT PIERCE, FL 34946 7.600 s Oct 3 2014 MiTek Industries, Inc. Fri Nov 07 09:12:06 2014 Page 1 ID:nTgtNvPNwyOwNLlv4xWHRyyMD8g-OdOKVo521LT6SDTpTv6811 aCXDh D7 W81LDL4WayLdt; 0-0-1 0-9-01-4-13 6-2-6 9.1-2 13.3-0 i 17-2-7 i 18-5-5 i 22-2-13 i -11-4-12 4-9-9 2-10-12 4-1-15 3-11-7 1-A 3-9.8 Q0.1 44 = 2.00 Ll2 Dead Load Deli. = 5/16 in 4.00 F12 3 3x4 = 3x4 % 4 4x4 2 = 5 1.5x4 11 6 1 7 1.5x4II 9 r Id 5x8 = 3x4 = 12 5x8 = 4x4 3x6 = 4x4 = I 12 0.50 12 1-4-13 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d TCLL 30.0 Plate Grip DOL 1.25 TC 0.62 Vert(LL) 0.28 9 >893 360 TCDL 15.0 Lumber DOL 1.25 BC 0.97 Vert(TL). -0.55 8-9 >455 240 BCLL 0.0 ` Rep Stress Incr YES WB 0.35 Horz(TL) 0.20 7 n/a n/a BCDL 10.0 Code FBC2010I PI2007 (Matrix-M) LUMBER - TOP CHORD 2x4 SP No.2 *Except* T1: 2x4 SP M 30 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 2-9-7 oc purlins. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation uide. REACTIONS. All bearings 0-8-0. (lb) - Max Horz 1= 71(LC 12) Max Uplift All uplift 100 lb or less at joint(s) 12 except 7=-444(LC 9), 1=-482(LC 8) Max Grav All reactions 250 Nor less at joint(s) 12 except 7=1199(LC 1), 1=1326(LC 1), 1=1326(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-3319/2169, 2-3=-2953/2007, 3-4=-2885/1967,4-5=-3704/2487, 5-6=-3773/2577, 6-7=-3851/2536 BOT CHORD 1-16=-1909/3021,1-12=-1909/3021, 11-12=-1914/3030, 10-11=-1921/3038, 9-10=-2254/3585, 8-9=-2213/3418, 7-8=-2311 /3581 WEBS 2-10=421/296, 3-10=-653/1023, 4-10=-904/638 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=S.Opsf; BCDL=5.Opsf; h=28ft; Cat. II; Exp'C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Extedor(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) The solid section of the plate is required to be placed over the splice line at joint(s) 12. 4) Plate(s) at joint(s) 3, 5, 7, 1, 10, 8, 2, 11, 4, 9 and 6 checked for a plus or minus 0 degree rotation about its center. 5) Plate(s) at joint(s)12 checked for a plus or minus 4 degree rotation about its center. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) : This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Bearing at joint(s) 7 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ito uplift at joint(s) 12 except (jt=lb) 7=444, 1=482, 1=482. 10) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard PLATES GRIP MT20 244/190 Weight: 95 lb FT = 0% Julius Lee, P.E. #34869—`1109 Coastal Bay— Boynton Beach, FL 33435 Job Truss Truss Type Qty Ply 59941 A07G Roof Special Girder 1 3 A0134329 Jab Reference (optional) Al ROOF TRUSSES, FORT PIERCE, FL 34946 7.600 s Oct 3 2014 MiTek Industries, Inc. Fri Nov 07 09:12:08 2014 Page 1 ID:nTgtNvPNwyOwNLIv4xWHRyyM D8g-yOW4wU6JHzjgh WcCaK8cgSfWUOPabRFboXgAaSyLdt° 0.0.1 0- 01-4-13 6-3-11 7-11-4 12-5.9 16-8-10 20-8-0 22-2-13 0- 1 1r1-12 4-10-14 1-7-9 45 4-3-1 83-11.6 1-6-13 0.0.1 44 = 2.00112 Dead Load Dell. = 5116 in 4.00 12 3x4 % 3 0 3x4 = 2 4 3x4 = 5 4 3x4 = 5 6 1 7 N 26 M 10 27 28 29 30 31 Id 11 6 8= 9 8 x 5x6 = 12 1.00 12 3x4 = 3x4 = 1-4-13 LOADING(psf) SPACING- 2-0-0 CSI. TCLL 30.0 Plate Grip DOL 1.25 TC 0.72 TCDL 15.0 Lumber DOL 1.25 BC 0.79 BCLL 0.0 ' Rep Stress Incr NO WB 0.31 BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP N0.2 *Except* B3,B4: 2x6 SP No.2, 135: 2x4 SP M 30 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. All bearings 0-8-0 except Qt=length) 7=0-6-8. (lb) - Max Horz 1= 62(LC 27) Max Uplift All uplift 100 lb or less at joint(s) except 7=-720(LC 5), 1=-1007(LC 4), 12=-361(LC 20) Max Gray All reactions 250 lb or less at joint(s) 12 except 7=1747(LC 1), 1=2448(LC 1), 1=2448(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-5795/2235, 2-3=-6172/2498, 3-20=-6247/2520, 20-21=-6273/2534, 4-21=-6329/2545, 4-22=-7944/3250, 22-23=-7986/3254, 5-23=-7997/3259, 5-24=-6991/2898, 24-25=-7033/2895, 6-25=-7035/2890, 6-7=-7020/2879 BOT CHORD 1-19=-155/255, 1-16=-2065/5357, 1-12=-2065/5357, 11-12=-2069/5367, 10-11=-2071/5384,10-26=-313W7898, 26-27=-3141/7894,9-27=3144/7890, 9-28=-2793/6895, 28-29=2794/6892, 8-29=-2795/6891, 8-30=-2785/6874, 30-31=-2786/6871, 7-31=2786/6871 WEBS 3-10=-954/2458, 2-11=-539/281, 2-10=-462/960, 4-10=-1826/832, 5-9=-422/1076, 5-8=-404/243 NOTES - 0.50112 7x6 = 1.5x4 11 DEFL. in (loc) I/deft Ud Vert(LL) 0.27 8-9 >932 360 Vert(TL) -0.57 8-9 >441 240 Horz(TL) 0.13 7 n/a n/a 1) 3-ply truss to be connected together with 1 Od (0.131"x3") nails as follows: Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x4 - 1 row at 0-9-0 oc, 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute.only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced roof live loads have been considered for this design. 4) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=28ft; Cat. _ II; Exp C; Encl., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed ; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 5) Plates checked for a plus or minus 0 degree rotation about its center. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) . This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Bearing at joint(s) 7 considers parallel -to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 720 lb uplift at joint 7, 1007 lb uplift at joint 1, 361 lb uplift at joint 12 and 1007 lb uplift at joint 1. 10) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 11) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 218 lb down and 179 lb up at 10-0-0, 177 lb down and 152 lb up at 12-0-0, 138 lb down and 127 lb up at 14-0-0, 98 lb down and 101 lb up at 16-0-0, and 75 lb down and 75 lb up at 18-0-0, and 62 lb down and 48 lb up at 20-0-0 on top chord, and 988 lb down and 445.lb up at 8-2-0, 87 lb down at 10-0-0, 63 lb down at 12-0-0, 40 lb down at 14-0-0, 19 lb down and 6 Ib up at 16-0-0, and 7 lb down and 11 lb up at 18-0-0, and 29 lb up at 20-0-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. Julius Lee, P.E. #34869— 1109 3x8 = PLATES GRIP MT20 244/190 Weight: 286 lb FT = 0% LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-90, 3-6=-90, 6-7=-90, 12-16=20, 10-12=20, 10-13=-20 Concentrated Loads (lb) Vert: 10=988(F) 20=-158(F) 21=-117(F) 22=-78(F) 23=-38(F) 24=3(F) 25=48(F) 26=-43(F) 27=-32(F) 28=-20(F) 29=-9(F) 30=3(F) 31=14(F) Coastal Bay —Boynton Beach, FL 33435 Job Truss Truss Type T Qty Ply A0134330 59941 B01G Monopitch Girder 1 1 ' Job Reference (optional) Al ROOF TRUSSES, FORT PIERCE, FL 34946 7.60U S OCt 3 2014 MI ICx Industnes, InC. rn NCV U/ U9:1Z:U9 ZU14 1.5x4 II 4 4x4 = 3x4 = 7 0.87 F12 0 9-7 , 1 6 8, 5-1-1 9-1-0 0 9-7 0-9-0 3-6-10 3-11-15 rn N Dead Load Dell. =1/16 in Plate Offsets (X,Y)--[2:0-4-9 0-0-11[5:0-2-8,0-2-131,[6:0-2-6,0-1-41 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.60 Vert(LL) 0.07 5-6 >999 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.80 Vert(TL) -0.15 5-6 >606 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.71 Horz(TL) 0.03 5 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight: 37 lb FT = 0% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 *Except* B2: 2x4 SP M 30 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 3-4-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 5-1-6 oc bracing. MiTek recommends that Stabilizers and required . cross bracing be installed during truss erection, in accordance with Stabilizer Installation cuide. REACTIONS. All bearings 0-8-13 except at --length) 5=Mechanical. (lb) - Max Harz 2= 164(LC 8) Max Uplift All uplift 100 lb or less at joint(s) except 2=-497(LC 8), 7=-195(LC 1), 5=-425(LC 12) Max Grav All reactions 250 lb or less at joint(s) 7 except 2=1202(LC 1), 5=1008(LC 1). 2=1202(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2230/1198 BOT CHORD 2-8=-1349/2075, 2-7=-1349/2075, 7-12=-1347/2069, 6-12=-1357/2098, 6-13=-1349/2068, 5-13=-1357/2093 WEBS 3-5=-2140/1390, 3-6=-244/804 NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) . Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=28ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 497 lb uplift at joint 2, 195 lb uplift at joint 7, 425 lb uplift at joint 5 and 497 lb uplift at joint 2. 7) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 8) Hanger(s).or other connection device(s) shall be provided sufficient to support concentrated load(s) 366 lb down and 157 lb up at 3-1-12, and 344 lb down and 142 lb up at 5-1-12, and 317 lb down and 141 lb up at 7-1-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads.(plf) Vert: 1-2=-30, 24=-90, 7-8=-20, 5-7=-20 Concentrated Loads (lb) Vert: 6=-344(B) 12=-366(B) 13=-317(B) -Julius Lee. P_E_ #34869— 1109 Coastal Bay— Boynton Beach, FL 33435 Job Truss Truss Type IOty Ply 59941 B02G Monopitch Girder 1 1 LbA0134331 Reference (optional) Al ROOF TRUSSES, FORT PIERCE, FL 34946 7.600 s Oct 3 2014 MiTek Industries, Inc. Fri Nov 07 09:12:10 2014 Page 1 ID:nTgtNvPNwyOwNLlv4xWHRyyMD8g-uPdrL98ZpazYxgmailB4wtktyg5E3Guu GrJHfLyLdt: 0-(-0 1-6-8 5-1-5 8-9-11 0- -1 1-6-8 3-6-13 3-8-6 1.5x4 II 4 Dead Load Der. =1/16 in 3x4 = 4x4 = 0.87 12 0-9-7 , 1-6-8 , 5-1-5 8-9-11 0_ _7 0-9-0 3-6-13 3-9-6 Plate Offsets (X,Y)— [2:0-4-9,0-0-11, r5:0-2-8,0-2-131, [6:0-2-6,0-0-121 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.59 Vert(LL) 0.07 5-6 >999 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.78 Vert(TL) -0.13 5-6 >647 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.62 Horz(TL) 0.03 5 n/a n/a BCDL 10.0 Code FBC201 O/TPI2007 (Matrix-M) Weight: 36 lb FT = 0% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 *Except* 132: 2x4 SP M 30 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 3-5-4 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 5-2-10 cc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 0-8-13 except Qt=length) 5=Mechanical. (lb) - Max Horz 2= 159(LC 12) Max Uplift All uplift 100 lb or less at joint(s) except 2=-493(LC 8), 7=-143(LC 1), 5=-444(LC 12) Max Grav All reactions 250 lb or less at joint(s) 7 except 2=1181(LC 1), 5=1041(LC 1), 2=1181(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2180/1158 BOT CHORD 2-8=-1300/2026,2-7=-1300/2026, 7-12=-1298/2016, 6-12=-1308/2047, 6-13=-1299/2016, 5-13=-130912044 WEBS 3-5=-2104/1350, 3-6=-269/850 NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=28ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and, right exposed ; end vertical left exposed;C-C for members and forces &. MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 493 lb uplift at joint 2, 143 lb uplift at joint 7, 444 lb uplift at joint 5 and 493 lb uplift at joint 2. 7) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 384 lb down and 163 lb up at 2-10-7, and 376 lb down and 153 lb up at 4-10-7, and 362 lb down and 168 lb up at 6-10-7 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-2=-30, 2-4=-90, 7-8=-20, 5-7=-20 Concentrated Loads (lb) Vert:6=-376(B) 12=-384(B) 13=-362(B) Julius Lee, P.E. #34869— 1109 Coastal Bay — Boynton Beach, FL 33435 Job Truss Truss Type Qty Ply 59941 C01 G Roof Special 1 1 A0134332 ' Job Reference (optional) Al ROOF TRUSSES, FORT PIERCE, FL 34946 7.600 s Oct 3 2014 MiTek Industries, Inc. Fri Nov 07 09:12:11 2014 Page 1 ID:nTgtNvPNwyOwNLIv4xWHRyyMD8g-MbBDYV8BZu5PY LnKTiJS4H7FEYmormlUV3gBnyLdt 0-0-1 0 -0 1-413 3-0-13 7-115 0 -1 1-4-12 1-1T 4-7-8 0-0-1 4x4 = 2.00112 2x4 II 6 3x4 = 1.00 12 0.50112 5x6 = 413 , 3-4-11 7-11-5 0-8-13 0-&-0 1-11-14 4-8-10 Plate Offsets (X,Y)—r1:0-0-14,0-5-141, I4:0-6-7,0-2-111 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.30 Vert(LL) -0.03 5-13 >999 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.37 Vert(TL) -0.06 5-13 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.07 Horz(TL) 0.01 4 n/a n/a BCDL 10.0 Code FBC201 O/TPI2007 (Matrix-M) Weight: 29 lb FT = 0% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 5) ' This truss has been designed for a live load of WEBS 2x4 SP No.3 20.Opsf on the bottom chord in all areas where a SLIDER rectangle 3-6-0 tall by 2-0-0 wide will fit between the BRACING- bottom chord and any other members. TOP CHORD 6) Bearing at joint(s) 4 considers parallel to grain value Structural woad sheathing directly applied or 5-7-3 oc usng ANSI/TPI 1 angle to grain formula. Buildingi purT designer should verify capacity of bearing surface. BOT CHORD 7) Provide mechanical connection (by others) of truss to Rigid ceiling directly applied or 8-5-11 oc bracing. bearing plate capable of withstanding 330 lb uplift at joint 1, 192 lb uplift at joint 6, 181 lb uplift at joint 4 and 330 lb MiTek recommends that Stabilizers and required uplift at joint 1. cross bracing be installed during truss erection, in 8) "Semi -rigid pitchbreaks with fixed heels" Member end accordance with Stabilizer Installation uide. fixity model was used in the analysis and design of this truss. REACTIONS. All bearings 0-8-0 except (jt=length) 4=0-6-13.9) Hanger(s) or other connection device(s) shall be (lb) - Max Horz provided sufficient to support concentrated load(s) 324 lb 1= 40(LC 37) down and 341 lb up at 3-3-13, and 129 lb down and 117 Max Uplift lb up at 5-5-0 on top chord, and 31 lb down and 17 lb up All uplift 100 lb or less at joint(s) at 3-4-11, and 21 lb up at 5-5-0 on bottom chord. The except 1=-330(LC 8). 6=-192(LC 26). design/selection of such connection device(s) is the 4=-181(LC 9) responsibility of others. Max Grav 10) In the LOAD CASE(S) section, loads applied to the All reactions 250 lb or less at face of the truss are noted as front (F) or back (B). joint(s) 6 except 1=675(LC 1), 4=424(LC 26), 1=675(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-981/530, 2-3=-918/525, 3-4=-650/447 BOT CHORD 1-7=-443/892, 1-6=-443/892, 5-6=-445/897, 5-15=-449/908, 4-15=-449/907 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.0psf; h=28ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Extedor(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Plates checked for a plus or.minus 0 degree rotation about its center. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-2=-90, 2-4=-90, 6-7=-20, 5-6=20, 5-11=-20 Concentrated Loads (lb) Vert: 2=-89(F) 5=-9(F) 3=30(F) 15=10(F) Julius Lee, P.E. #34869— 1109 Coastal Bay — Boynton Beach, FL 33435 Job Truss Truss Type f Qty Ply A0134333 59941 CO2 Roof Special 1 1 Job Reference (optional) Al ROOF TRUSSES, FORT PIERCE, FL 34946 7.600 s Oct 3 2014 MiTek Industries, Inc. Fri Nov 07 09:12:12 2014 Page 1 ID:nTgtNvP NwyOwNLIv4xWHRyyMD8g-gnlbmr9pKBDGA8wzpADY?IpGAdx_XGuBj9oOjEyLdt, 0-0-1 0 1113 45-11 7-115 0 -1 1-4-12 3-0-14 3-5-10 0-0-1 4x4 = 2.00112 3x4 = 4.00 3x4 = LOADING(psfl SPACING- 2-0-0 TCLL 30.0 Plate Grip DOL 1.25 TCDL 15.0 Lumber DOL 1.25 BCLL 0.0 ' Rep Stress Incr YES BCDL 10.0 Code FBC201 O/TPI2007 LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 cc purlins. BOT CHORD Rigid ceiling directly applied or 8-4-7 cc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 0-8-0 except (jt=length) 4=Mechanical. (lb) - Max Horz 1= 73(LC 12) Max Uplift All uplift 100 lb or less at joint(s) 6 except 1=7202(1-C 8), 4=-137(LC 9) Max Grav All reactions 250 lb or less at joint(s) 6 except 1=487(LC 1), 4=386(LC 1), 1=487(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-710/538, 2-3=-651/535 BOT CHORD 1-7=-497/617, 1-6=-497/617, 5-6=-499/622 WEBS 3-4=-419/387, 3-5=-503/631 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=28ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 1.00 12 0.50112 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TC 0.42 Vert(LL) 0.02 5 >999 360 MT20 244/190 BC 0.18 Vert(TL) -0.03 4-5 >999 240 WB 0.21 Horz(rL) 0.01 4 n/a n/a (Matrix-M) Weight: 31 lb FT = 0% 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall, by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6 except (jt=lb) 1=202, 4=137, 1=202. 8) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Julius Lee, P.E. #34869 — 1109 Coastal Bay — Boynton Beach, FL 33435 Job Truss Truss Type t Qty Ply A0134334 59941 CO3 Roof. Special 1 1 Job Reference (optional) Al ROOF TRUSSES, FORT PIERCE, FL 34946 7.600 s Oct 3 2014 MiTek Industries, Inc. Fri Nov 07 09:12:12 2014 Page 1 ID:nTgtNvPNwyOwNLlv4xWHRyyMD8g-gnlbmr9pKB DGA8wzpADY?IpEmdveXHgBj9oOjEyLdt1 0-0-1 0 1- 13 5-7-9 7-11-5 1 1-4-12 4 2-12 2-3-12 0-0-1 4x4 = 2.00112 ..... r,77 ` 3x4 ZZ 3x4 = 6 3x4 = 1 00 F12 0.50112 0-8-13 , 1 4-13 , 5-8-7 , 7-11-5 0-8-13 0-8-0 4-3-10 2-2-14 Plate Offsets(X,Y)--11:0-3-14,0-1-01,15:0-4-8 0-2-01 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.57 Vert(LL) -0.02 5-6 >999 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.27 Vert(TL) -0.06 5-6 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.15 Horz(TL) 0.00 4 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight: 31 lb FT = 0% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 cc purlins, except end verticals. BOT CHORD - Rigid ceiling directly applied or 9-10-14 cc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 0-8-0 except Qt=length) 4=Mechanical. (lb) - Max Horz 1= 105(LC 12) Max Uplift All uplift 100 lb or less at joint(s) except 1=-138(LC 8), 6=-108(LC 8), 4=-122(LC 9) Max Grav All reactions 250 lb or less at joint(s) 6 except 1=351(LC 1), 4=364(LC 1), 1=351(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-483/318, 2-3=-415/351, 3-4=-407/366 BOT CHORD 1-7=-331/399,1-6=-331/399,5-6=-334/403 WEBS 3-5=-371 /452 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=28ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 138 lb uplift at joint 1, 108 lb uplift at joint 6, 122 lb uplift at joint 4 and 138 lb uplift at joint 1. 8) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Julius Lee, P-E. #34869 — 1109 Coastal Bay — Boynton Beach, FL 33435 Job Truss Truss Type f / Qty Ply A0134335 59941 C04 Roof Special 1 1 Job Reference o tional Al ROOF TRUSSES, FORT PIERCE, FL 34946 7.600 s Oct 3 2014 MiTek Industries, Inc. Fri Nov 07 09:12:13 2014 Page 1 ID:nTgtNvPNwyOwNLlv4xWHRyyMD8g-I_JzzBAR5VL7olV9NtknXVMLg1 CKGIcKypYxFgyLdt 0-0-1 0 1�-13 6-9-6 7-11 5 0 -1 1412 5-4-9 1-1-15 0-0-1 4x4 — — 2.00 12 L- 3x4 = Dead Load Dell. =1/16 in 4.00 12 T2 Ti W1 3 B3 ez. 1 g 5x6 = 4 B 5 1.5x411 3x8 = 3x4 = 0.50 12 6 1.00 12 LOADING(psf) SPACING- 2-0-0 TCLL 30.0 Plate Grip DOL 1.25 TCDL 15.0 Lumber DOL 1.25 BCLL 0.0 ' Rep Stress Incr YES BCDL 10.0 Code FBC201 O/TPI2007 LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 0-8-0 except Ot=length) 4=Mechanical. (lb) - Max Horz 1= 137(LC 12) Max Uplift All uplift 100 lb or less at joint(s) 1 except 6=-214(LC 8), 4=-121(LC 8) Max Grav All reactions 250 lb or less at joint(s) 1, 1 except 6=344(LC 25), 4=337(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-278/308, 34=-390/343 BOT CHORD 1-10=-465/405 WEBS 2-5=-227/277, 3-5=-296/351 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=28ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5-5-7 11-1 CSI. DEFL. in (loc) I/defi Ud TC 0.82 Vert(LL) -0.01 7 >830 360 BC 0.50 Vert(fL) -0.13 5-6 >571 240 WB 0.11 Horz(TL) 0.00 4 n/a n/a (Matrix-M) 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb iuplift at joint(s) 1, 1 except Qt=lb) 6=214, 4=121. 8) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard PLATES GRIP MT20 244/190 Weight: 31 lb FT = 0% Julius Lee, P.E. #34869 — 1109 Coastal Bay — Boynton Beach, FL 33435 Job Truss Truss Type t 1 city Ply 59941 CACorner Jack 1 .1 A0134336 Job Reference (optional) Al ROOF TRUSSES, FORT PIERCE, FL 34946 7.600 s Oct 3 2014 MiTek Industries, Inc. Fri Nov 07 09:12:13 2014 Page 1 ID:nTgtNvPNwyOwNLlv4xWHRyyMD8g-I_JzzBAR5VL7o1V9NtknXVMXml JfGmM KypYxFgyLdt 0-0-1 1-4-13 2-1 N--2 1 1-4-12 2 4 3x4 = 0-8-13 1413 2-1-2 0 8-13 Plate Offsets (X,Y)--[1:0-0-14,0-5-141 LOADING(psf) SPACING- 2-0-0 CS1. DEFL. in ([cc) I/deft Ud PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.04 Vert(LL) -0.00 5 >999 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.03 Vert(TL) -0.00 5 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 2 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) Weight: 7 lb FT = 0% LUMBER TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- LOAD CASE(S) TOP CHORD Standard Structural wood sheathing directly applied or 2-1-2 oc pudins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 0-8-0 except (jt=length) 2=Mechanical, 3=Mechanical. (lb) - Max Harz 1= 43(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 2, 4 except 1=-116(LC 8) Max Grav All reactions 250 lb or less at joint(s) 2, 1, 4, 3, 1 FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=28ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 4 except (jt=lb) 1=116, 1=116. 7) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. Julius Lee, P-E. #34869— 1109 Coastal Bay — Boynton Beach, FL 33435 Job Truss Truss Type 1 �► Oty Ply AO134337 59941 CJAA Corner Jack 1 1 Lb.. Reference o tional Al ROOF TRUSSES, FORT PIERCE, FL 34946 7.600 s Oct 3 2014 MiTek Industries, Inc. Fri Nov 07 09:12:14 2014 Page 1 ID:nTgtNvPNwyOwNLIv4xWHRyyMD8g-nAtLBXB3sp-rPR4MxbF04jvhjRfw?DcUBTHVo6yLdt' 1-10-9 1-10-9 1 2x4 = 1-6-1 1-6-1 1-10-9 0-4-9 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.09 Vert(LL) -0.00 4 >999 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.03 Vert(TL) -0.01 4 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 3 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight: 6 lb FT = 0% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 1-10-9 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation Quide. REACTIONS. (lb/size) 1 = 108/0-8-0 (min. 0-1-8) 3 = 4/Mechanical 2 = 93/Mechanical Max Horz 1 = 40(LC 8) Max Uplift 1 = -34(LC 8) 2 = -49(LC 8) Max Gray 1 = 108(LC 1) 3 = 7(LC 3) 2 = 93(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=S.Opsf; h=28ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Bearing at joint(s) 1 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 2. 8) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Julius Lee, P.E. #34869 — 1109 Coastal Bay — Boynton Beach, FL 3343S Job Truss Truss Type , T Qty Ply 59941 D01G Roof Special 1 1 A0134338 Job Reference (optional) Al ROOF TRUSSES, FORT PIERCE, FL 34946 7.600 s Oct 3 2014 MiTek Industries, Inc. Fri Nov 07 09:12:15 2014 Page 1 ID:nTgtNvPNwyOwNLlv4xWHRyyMD8g-FMRkOtCid6bg1 bfYUlmFcwRg5rvlkfSdP712KYyLdt_ 3-0-14 6-7-11 7-8-4 3-0 14 3-6-13 1-0 10 4x4 = . 2x4 11 1.00 12 0.50112 LOADING(psf) SPACING- 2-0-0 TCLL 30.0 Plate Grip DOL 1.25 TCDL 15.0 Lumber DOL 1.25 BCLL 0.0 ` Rep Stress Incr YES BCDL 10.0 Code FBC2010/TPI2007 LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 SLIDER BRACING - TOP CHORD Structural wood sheathing directly applied or 5-6-13 oc purlins. BOT CHORD Rigid ceiling directly applied or 7-5-13 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation quide. REACTIONS. (lb/size) 1 = 468/0-8-0 (min. 0-1-8) 4 = 409/1-0-10 (min. 0-1-8) Max Horz 1 = 35(LC 37) Max Uplift 1 = -189(LC 8) 4 = -174(LC 9) Max Grav 1 = 468(LC 1) 4 = 409(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1070/654, 2-3=-1060/670, 3-4=-783/585 BOT CHORD 1-6=-570/994, 5-6=-561/985, 5-14=-590/1031, 4-14=-590/1029 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=28ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Extedor(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. CSI. DEFL. in (loc) I/defl Ud TC 0.24 Vert(LL) -0.04 6 >999 360 BC 0.37 Vert(TL) -0.08 6 >999 240 WB 0.09 Horz(fL) 0.02 4 n/a n/a (Matrix-M) 5) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing atjoint(s) 1, 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at --lb) 1=189, 4=174. 8) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 330 lb down and 3$3 lb up at 3-0-14, and 127 lb down and 110 lb up at 5-2-4 on top chord, and 24 lb down and 21 lb up at 3-0-14, and 26 lb up at 5-2-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase--1.25 Uniform Loads (plf) Vert: 1-2=-90, 2-4=-90, 6-7=-20, 6-10=-20 Concentrated Loads (Ib) Vert: 2=-84(F) 3=42(F) 5=-2(F) 14=13(F) PLATES GRIP MT20 244/190 Weight: 28 lb FT = 0% Julius Lee. P.E. #34869— 1109 Coastal Bay— Boynton Beach, FL 33435 0 dI9 a Job Truss Truss Type 1 Qty Ply A0134339 59941 D02 Roof Special 1 1 Job Reference o tional Al ROOF TRUSSES, FORT PIERCE, FL 34946 7.600 s Oct 3 2014 MiTek Industries, Inc. Fri Nov 07 09:12:15 2014 Page 1 ID:nTgtNvPNwyOwNLlv4xWHRyyMD8g-FMRkOtCid6bg1 bfYUlmFcwRnlrwukcpdP712KYyLdt_ 4-2-11 7-8-4 4-2-11 3-5-9 4x4 = 2.00112 3x4 = 3 T2 T1 W1 rn VJd B1 B2 Cn 6 q d — 5 4x4 = 4 jd 6 3x4 — 6 6 1 5x4 II 2x4= 1.00 F12 0.50 12 3-9-12 3-9-12 0-4-15 3-5-9 Plate Offsets (X Y)--14.0-2-8 0-0-121 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.39 Vert(LL) 0.04 6-9 >999 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.30 Vert(TL) -0.06 6-9 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.26 Horz(TL) 0.01 4 n/a n/a BCDL 10.0 Code FBC201 O/TPI2007 (Matrix-M) Weight: 30 lb FT = 0% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 5-10-9 oc purlins. BOT CHORD Rigid ceiling directly applied or 7-0-3 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 1 = 42610-8-0 (min. 0-1-8) 4 = 404/Mechanical Max Horz 1 = 68(LC 12) Max Uplift 1 = -149(LC 8) 4 = -143(LC 9) Max Grav 1 = 426(LC 1) 4 = 404(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-859/716, 2-3=-815/670 BOT CHORD 1-6=-829/879, 5-6=-626/768 WEBS 3-4=-471 /431, 3-5=-636/794 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=28ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections.. 7) Bearing at joint(s) 1 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=1b) 1=149, 4=143. 9) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Julius Lee, PIE. #34869— 1109 Coastal Bay — Boynton Beach, FL 33435 Jab Truss Truss Type 1 t Qty Ply \ A0134340 59941 D03 Roof Special 1 1 Job Reference (optional) Al ROOF TRUSSES, FORT PIERCE, FL 34946 7.600 s Oct 3 2014 MiTek Indus myOwN Llv4xW H RyyM D8g-jZ?6 cDC K 7-8-4 2-3-11 4x4 = 2,00112 2 3x4 = 1.00 12 0.50 L12 4-11-10 54-9 7-84 d-11-1n -d-1. 9-1-1, Inc. Fri Nov 07 09:12:16 2014 Plate Offsets (X,Y)--14:0-2-8,0-0-121 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.56 Vert(LL) 0.07 6-9 >999 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.42 Vert(TL) -0.10 6-9 >899 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.19 Horz(TL) 0.01 4 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) Weight: 30 lb FT = 0% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 5-7-1 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 7-9-4 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 1 = 434/0-8-0 (min. 0-1-8) 4 = 396/Mechanical Max Harz 1 = 100(LC 12) Max Uplift 1 = -156(LC 8) 4 = -133(LC 9) Max Grav 1 = 434(LC 1) 4 = 396(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1106/990, 2-3=-534/447, 3-4=-490/433 BOT CHORD 1-6=-1222/1258, 5-6=-429/513 WEBS 3-5=-478/585 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=28ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Bearing at joint(s) 1 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 1=156, 4=133. 9) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Julius Lee, P-E. #34869— 1109 Coastal Bay —Boynton Beach, FL 33435 Job Truss Truss Type t Qty Ply A0134341 59941 D04 Roof Special 1 1 Job Reference o tional Al ROOF TRUSSES, FORT PIERCE, FL 34946 7.600 s Oct 3 2014 MiTek Industries, Inc. Fri Nov 07 09:12:16 2014 Page 1 ID:nTgtNvPNwyOwNLIv4xWHRyyMDBg-jZ?6cDCKOQjhflDk20HU98_sEFB9T5bmenmbr .?yLds: 6-6-7 7-8-4 6-6-7 1-1-14 4x4 = 2.00112 Dead Load Defl. = 118 in 3x4 = 2 3 4.00 12 T2 T1 W1 W3 d o_ Bi 6'$ 5 3x4= 4 G 3x4 = 6 1.5x4 II 3x4 = 0.50 12 1.00 12 LOADING(psf) SPACING- 2-0-0 TCLL 30.0 Plate Grip DOL 1.25 TCDL 15.0 Lumber DOL 1.25 BCLL 0.0 • Rep Stress Incr YES BCDL 10.0 Code FBC2010/TPI2007 LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 4-6-4 oc pudins, except end verticals. BOT CHORD Rigid ceiling directly applied or 9-5-9 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation ouide. REACTIONS. (lb/size) 1 = 448/0-8-0 (min. 0-1-8) 4 = 382/Mechanical Max Horz 1 = 132(LC 12) Max Uplift 1 = -159(LC 8) 4 = -148(LC 8) Max Grav 1 = 448(LC 1) 4 = 382(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1609/1458,3-4=-534/443 BOT CHORD 1-6=-1855/1899 WEBS 2-5=-218/274, 3-5=-398/498 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=28ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. CSI. DEFL. in (Ioc) I/defl Ud TC 0.80 Vert(LL) 0.14 6-9 >664 360 BC 0.62 Vert(TL) -0.20 6-9 >449 240 WB 0.16 Horz(TL) 0.01 1 n/a n/a (Matrix-M) 5) . This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Refer to girder(s) for truss to truss connections. 7) Bearing at joint(s) 1 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=1b) 1=159, 4=148. 9) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard PLATES GRIP MT20 244/190 Weight: 30 lb FT = 0% Julius Lee, P.E. #34569 — 1109 Coastal Bay — Boynton Beach, FL 33435 Job Truss Truss Type 4 t Qry Ply 59941 FG01 FLOOR 1 2 A0134342 Job Reference o tional Al ROOF TRUSSES, FORT PIERCE, FL 34946 7.600 s Oct 3 2014 MiTek Industries, Inc. Fri Nov 07 09:12:17 2014 Page 1 ID:M8gdRulfexyWoi5_CtkLoayLvGV-BIYUpYDy9krYGvoxclpjiLX5JeV8CSKvAQ W9NRyLdsI 3 4 3 6-2-14 9-1-10 12-0-5 15 0-12 17-0-12 20-1-0 3-4-3 2-10-11 2-10-11 2-10-11 3-0-7 2-0-0 3-0 4 Dead Load Deli. = 1/8 in 3x4 = 3x4 = 2x4 11 7x6 = 3x4 = 1.5x4 11 4x6 = 14x6 2 3 4 5 6 7 8 17 16 15 3x4 [I- 4x4 = 3x4 = 3-4-3 1 6-2-14 14 13 12 4x4 = 3x8 = 3x4 = 9-1-10 12-0-5 1 15-0-12 11 10 1.5x4 If 4x4 = 17-0-12 20-1-0 9. 3x4 11 3-4-3 2-10-11 2-10-11 2-10-11 3-0-7 2-0-0 3-0-4 Plate Offsets (X,Y)— (1:0-2-4,0-2-01,f5:0-3-0,0-3-41,18:0-2-4,0-2-01,I9:0-2-0,0-2-61,f17:0-2-0,0-1-141 LOADING(psf) SPACING- 2-0-0 CS1. DEFL. in (Icc) I/deft L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.52 Vert(LL)-0.2511-12 >936 480 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0.76 Vert(TL)-0.3911-12 >599 360 BCLL 0.0 Rep Stress Incr NO WB 0.51 Horz(TL) 0.04 9 n/a n/a BCDL 5.0 Code FBC2010/TP12007 (Matrix-M) Weight: 218 lb FT = 0% LUMBER TOP CHORD 2x6 SP No.2 *Except* T2: 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.2 *Except* W1,W7: 2x8 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 5-9-9 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 9-10. REACTIONS. (lb/size) 17 = 1763/Mechanical 9 = 1364/Mechanical Max Grav 17 = 1763(LC 1) 9 = 1364(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-17=-1706/0, 1-2=-3398/0, 2-3=-5395/0, 3-4=-6032/0, 4-5=-6037/0, 5-6=5470/0, 6-7=-3111/0, 7-8=-3111/0, 8-9=-1590/0 BOT CHORD 15-1 6=0/3398,14-15=0/5395, 13-14=0/5395, 12-13=0/5557, 11-12=0/3111, 10-11=0/3111 WEBS 7-10=-965/0, 6-11=-693/0, 8-10=0/3643, 6-12=0/2663, 1-16=0/3419, 5-12=-832/0, 2-16=-134010, 5-13=0/550, 2-15=0/2184, 4-13=-556/0, 3-15=-840/0, 3-13=0/697 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x8 - 2 rows staggered at 0-9-0 oc, 2x6 - 2 rows staggered at 0-9-0 oc, 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x4 -1 row at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced floor live loads have been considered for this design. 4) Plates checked for a plus or minus 0 degree rotation about its center. 5) Refer to girder(s) for truss to truss connections. 6) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of -this truss. 7) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. LOAD CASE(S) Standard 1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 - Uniform Loads (plf) Vert: 1-5=-185(B=-85), 5-8=-100, 9-17=-10 Julius Lee, P.E. #34869 — 1109 Coastal Bay — Boynton Beach, FL 33435 Job Truss Truss Type t �I Qty ply A0134343 59941 ` FG02 FLOOR 1 Z Jab Reference optional Al ROOF TRUSSES, FORT PIERCE, FL 34946 7.600 s Oct 3 2014 MiTek Industries, Inc. Fri Nov 07 09:12:17 2014 Page 1 ID:M8gdRulfexyWoi5_CtkLoayLvGV-BIYUpYDy9krYGvoxcjpjiLXAEeZrC WaMQW9NRyLds1 2-9-12 7-2-7 11-10-12 2-9-12 4-4-11 4-8-5 4x6 = LOADING(psf) SPACING- 2-0-0 TCLL 40.0 Plate Grip DOL 1.00 TCDL 10.0 Lumber DOL 1.00 BCLL • 0.0 Rep Stress Incr NO BCDL 5.0 Code FBC201 OITP12007 LUMBER - TOP CHORD 2x6 SP No.2 BOT CHORD 2x6 SP No.2 WEBS 2x4 SP No.2 *Except* W3: 2x8 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. (lb/size) 5 = 1102/04-0 (min.0-1-8) 7 = 2644/04-0 (min. 0-1-9) Max Grav 5 = 1134(LC 4) 7 = 2644(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2210/0, 3-4=-426/0, 4-5=-299/0 BOT CHORD 6-12=0/2210, 12-13=012210, 5-13=0/2210 WEBS 2-7=-1651/0, 3-5=-1849/0, 2-6=0/2166, 3-6=0/396 NOTES- 1) 2-ply truss to be connected together with 10d (0.131 "x3") nails as follows: Top chords connected as follows: 2x4 -1 row at 0-9-0 oc, 2x6 - 2 rows staggered at 0-9-0 oc, 2x8 - 2 rows staggered at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc, 2x8 - 2 rows staggered at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced Floor live loads have been considered for this design. 4) Plates checked for a plus or minus 0 degree rotation about its center. 5) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this CSI. DEFL. in (loc) I/deft Ud TC 0.20 Vert(LL) -0.04 6 >999 480 BC 0.46 Vert(TL) -0.05 5-6 >999 360 WB 0.31 Horz(TL) 0.01 5 n/a n/a (Matrix-M) 6) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 cc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 500 lb down at 2-10-8 on top chord, and 397 lb down at 1-8-15, 397 lb down at 3-8-15, 397 lb down at 5-8-15, and 397 lb down at 7-8-15, and 397 lb down at 9-8-15 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 14=-100, 5-8=-10 Concentrated Loads (lb) Vert: 2=-500(B) 9=-397(F) 10=-397(F) 11=397(F) 12=-397(F)13=-397(F) 4x6 = PLATES GRIP MT20 244/190 Weight: 155 lb FT = 0% Julius Lee, P.E_ #34869— 1109 Coastal Bay— Boynton Beach, FL 33435 Job Truss Truss Type A f Qty Ply 59941 FG03 FLOOR 1 A0134344 Job Reference o tional Al ROOF TRUSSES, FORT PIERCE, FL 34946 7.600 s Oct 3 2014 MiTek Industries, Inc. Fri Nov 07 09:12:17 2014 Page 1 ID:M8gdRulfexyWoi5_CtkLoayLvGV-BIYUpYDy9krYGvoxcjpjiLX6YeggCaLwtQ W9N RyLds1 4-3-12 4-3-12 1 46 = 2 2x4 11 2x4 11 4x6 = LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.50 Vert(LL) 0.00 4 :"` 480 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0.01 Vert(fL) -0.00 34 >999 360 BCLL 0.0 Rep Stress Incr NO WB 0.00 Horz(TL) -0.00 3 n/a n/a BCDL 5.0 Code FBC2010/TPI2007 (Matrix-M) Weight: 58 lb FT = 0% LUMBER - TOP CHORD 2x6 SP No.2 BOT CHORD 2x6 SP No.2 WEBS 2x6 SP No.2 *Except* W2: 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 4-3-12 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 4 = 790/Mechanical 3 = 790/0-4-0 (min. 0-1-8) Max Grav 4 = 790(LC 1) 3 =. 790(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-4=-771 /0, 2-3=-771 /0 NOTES- 1) 2-ply truss to be connected together with 10d (0.131'W") nails as follows: Top chords connected -as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) Refer to girder(s) for truss to truss connections. 5) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 6) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131 " X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. Standard 1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 1-2=400(F=-300), 3-4=-10 LOAD CASE(S) Standard Julius Lee, P-E. #.S4869 — 1109 Coastal Bay — Boynton Beach; FL 33435 Job Truss Truss Type r ; Oty Ply 59941 FG21 FLOOR 1 A0134345 Job Reference (optional) Al ROOF TRUSSES, FORT PIERCE, FL 34946 7.600 s Oct 3 2014 MiTek Industries, Inc. Fri Nov 07 09:12:18 2014 Page 1 ID:M8gdRulfexyWoi5_CtkLoayLvGV-fx6sOuEawl zPu3N7ARKyEZ3Gj2npxsT354FiwtyLds: 3-34 6-1-0 8-10-11 11-8-7 14-11-11 3-3-4 2-9-12 2-9-12 2-9-12 3-34 1.5x4 11 3x4= 1 48 = 2 3x4 = 3x4 = Dead Load Dell. = 1/8 in 48 = I■� PEO=-R .__�� 12 13 11 14 15 10 16 17 94x4= 18 65x6= 19 46 11 5x6 = 3x8 = 46 11 3-3-4 6-1-0 8-10-11 11-8-7 14-11-11 3-3-4 2-9-12 2-9-12 2-9-12 3-3-4 Plate Offsets (X Y)--[5:0-1-12,0-1-81,f6:0-3-4,0-2-01,[7:0-3-0,0-1-141.fl1:0-3-0,0-2-121 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (Icc) I/deft . L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.54 Vert(LL) -0.18 9-10 >974 480 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0.99 Vert(TL) -0.30 9-10 >578 360 BCLL 0.0 Rep Stress Incr NO WB 0.71 Horz(TL) 0.03 7 n/a n/a BCDL 5.0 Code FBC2010/TPI2007 (Matrix-M) Weight: 171 lb FT = 0% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x6 SP No.2 WEBS 2x4 SP No.2 'Except' W1: 2x8 SP No.2, W3: 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 4-1-3 cc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 cc bracing. REACTIONS. (Ib/size) 12 = 2600/Mechanical 7 = 1637/Mechanical Max Grav 12 = 2600(LC 1) 7 = 1637(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOP CHORD 1-12=-2130/0, 1-2=-5249/0, 2-3=-7090/0, 3-4=-7090/0, 4-5=-6418/0, 5-6=3694/0, 6-7=-1460/0 BOT CHORD 12-13=0/520, 11-13=0/520, 11-14=0/5249, 14-15=0/5249, 10-15=0/5249, 10-16=0/6418, 16-17=0/6418, 9-17=0/6418, 9-18=0/3694, 8-18=0/3694, 8-19=01291, 7-19=0/291 WEBS 6-8=0/3635, 1-11=0/5052, 5-8=-1328/0, 2-11=-1304/0, 5-9=0/2930, 2-10=0/1980, 4-9=-708/0, 3-1 0=-581/0, 4-10=0/723 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x8 - 2 rows staggered at 0-9-0 cc, 2x4 - 1 row at 0-9-0 cc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. Webs connected as follows: 2x4 - 1 row at 0-9-0 cc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) Refer to girder(s) for truss to truss connections. 5) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 6) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 cc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 483 lb down at 1-9-4, 402 lb down at 3-9-4, 321 lb down at 5-94, 240 lb down at 7-9-4, 145 lb down at 8-2-5, and 82 lb down at 10-6-0, and 37 lb down at 12-9-12 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 1-4=-210, 4-6=-100, 7-12=-10 Concentrated Loads (Ib) Vert: 13=-483(F) 14=-402(F) 15=321(F) 16=-240(F) 17=-145(F) 18=-82(F) 19=-37(F) Julius Lee, P.E. #34869 — 1109 Coastal Bay — Boynton Beach, FL 33435 Job Truss Truss Type t Qry Ply 59941 FG22 FLOOR 1 2 A0134346 Job Reference (optional) Al ROOF TRUSSES, FORT PIERCE, FL 34946 7.600 s Oct 3 2014 MiTek Industries, Inc. Fri Nov 07 09:12:18 2014 Page 1 ID:M8gdRulfexyWoi5_CtkLoayLvGV-fx6sOuEawl zPu3N7ARKyEZ31X2oFxpV354FiwtyLds 2-11-8 4-10-1 6 10-5 9-0-1 11-0-6 12-10-14 15-10-6 2-11-8 1-10 8 2-0-5 2-1-12 2-0-5 1-10-8 2-11-8 Dead Load Defl. =1116 in 1.5x4 11 3x4 = 1.5x4 11 1.5x4 11 3x4 = 1.5x4 11 4x10 - 1 4x10= 2 3 4 5 6 7 8 PO-44 14 13 12 11 4x4 11 4x10 = 7x6 = 7x6 = 2-11-8 1 6-10-5 1 8-0-1 , 9-0-1 , 12-10-14 15 10 9 4x10 = 44 11 15-10-6 2-11-8 3-10-13 ' 1-1-12 ' 1-0-0 ' 3-10-13 2-11-8 Plate Offsets (X,Y)--r9:0-2-0,0-1-141, r10:0-1-12,0-2-41, f11:0-3-0,0-3-41, j12:0-3-0,0-3-41, r13:0-4-12,0-2-41, [14:0-2-0,0-1-61 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.42 Vert(LL) -0.13 11 >999 480 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0.90 Vert(TL) -0.20 11 >896 360 BCLL 0.0 Rep Stress Incr NO WB 0.90 Horz(TL) 0.02 9 n/a n/a BCDL 5.0 Code FBC201 O/TP12007 (Matrix-M) Weight: 172 lb FT = 0% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x6 SP No.2 *Except* 132: 2x4 SP No.2 WEBS 2x4 SP No.3 *Except* W1: 2x8 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 5-8-1 oc pudins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. Qb/size) 14 = 1094/Mechanical 9 = 1804/Mechanical Max Grav 14 = 1094(LC 1) 9 = 1804(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-14=-930/0, 1-2=-2042/0, 2-3=2042/0, 3-4=-4125/0, 4-5=-4181/0, 5-6=-4188/0, 6-7=-3788/0, 7-8=-3788/0, 8-9=-1683/0 BOT CHORD 12-13=0/3211, 11-12=0/4181, 11-15=0/4310, 10-15=0/4339, 9-10=0/292 WEBS 4-12=-491/0,1-13=0/1991, 8-10=0/3790, 3-13=-136110, 3-12=0/1309, 6-11=-446/48, 6-10=-610/0 NOTES- 1) 2-ply truss to be connected together with 1 Od (0.131"xW) nails as follows: Top chords connected as follows: 2x8 - 2 rows staggered at 0-9-0 oc, 2x4 - 1 row at 0-9-0 oc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-7-0 oc, 2x4 - 1 row at 0-9-0 oc. Webs connected as follows: 2x4 -1 row at 0-9-0 oc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Unbalanced floor live loads have been considered for this design. 4) Plates checked for a plus or minus 0 degree rotation about its center. 5) Refer to girder(s) for truss to truss connections. 6) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 7) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1219 lb down at 12-4-8 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 1-8=-100, 9-14=-10 Concentrated Loads (lb) Vert: 16=1219(F) Julius Lee, P-E. ii34869— 1109 Coastal Bay — Boynton Beach, FL 33435 Job Truss Truss Type t Qty Ply 59941 FG23 FLOOR 1 2 A0134347 Job Reference o tional Al ROOF.TRUSSES, FORT PIERCE, FL 34946 7.600 s Oct 3 2014 MiTek Industries, Inc. Fri Nov 07 09:12:19 2014 Page 1 ID:M8gdRulfexyWoi5_CtkLoayLvGV-78gEEEFChL5GWDyJj8rBnmcW9SI WgNRDKk?GSKyLdsv 2-10-7 5-8-15 2-10-7 2-10-8 1.5x4 II 1 3x6 = 3x6 = W1 W2 Ll W3 W2 W1 6 3x4 11 0-7 5 3x6 = 2-10-8 3x4 = Plate Offsets (X Y)--(1:0-2-4 0-1-81 I3:0-2-4,0-1-81,f4:0-1-14 0-1-81,I5:0-3-0 0-1-81 f6:0-2-0 0-1-141 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc)- I/deft Ud PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.24 Vert(LL) -0.02 5 >999 480 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0.32 Vert(TL) -0.03 5 >999. 360 BCLL 0.0 Rep Stress Incr NO WB 0.47 Horz(TL) -0.00 4 n/a n/a BCDL 5.0 Code FBC2010/TPI2007 (Matrix-M) Weight: 69 lb FT = 0% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x6 SP No.2 WEBS 2x4 SP No.3 `Except' Wl: 2x8 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 5-8-15 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 cc bracing. REACTIONS. (lb/size) 6 = 1441/Mechanical 4 = 1231/Mechanical Max Grav 6 = 1441(LC 1) 4 = 1231(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-6=-1038/0, 1-2=-1829/0, 2-7=-1829/0, 3-7=-1829/0, 3-4=-924/0 WEBS 3-5=0/1994, 1-5=0/1994, 2-5=-545/0 NOTES- 1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x8 - 2 rows staggered at 0-9-0 cc, 2x4 - 1 row at 0-9-0 cc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 cc. Webs connected as follows: 2x4 -1 row at 0-9-0 cc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) Refer to girder(s) for truss to truss connections. 5) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 6) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 753 lb down at 1-5-5, and 690 lb down at 3-9-0, and 256 lb down at 4-0-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. LOAD CASE(S) Standard 1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 1-7=-210, 3-7=-100, 4-6=-10 Concentrated Loads (lb) Vert: 8=-753(B) 9=-946(F=-256, B=-690) Julius Lee, P.E. #34869— 1109 Coastal Bay— Boynton Beach, FL 33435 Job Truss Truss Type I Qty Ply 59941 FG24 FLOOR 1 J A0134348 b Reference o tional Al KUUt- IKUbbtb, rUKI MtKUt, rL;4y40 2-7-4 2-7-4 1 3x8 = W1 2x4 II iF 2-3-8 1.5x4 11 3x4 = 2 3 T1 Ll VV3 W2 W3 B1 9 7 10 4x10 = /.tiUU S UCI :i LU14 MI I eK /cis tkLoayLvGV-78gEE 7-6-0 2-7-4 6 11 46 = V✓2 Inc. Fri Nov 07 09:12:19 2014 Page 1 3x8 = 4 iW 2x4 11 Plate Offsets X -- 1:0-3-0 0-1-8 4:0-3-8 0-1-8 6:0-2-8 0-2-0 :04-0 0-2-0 LOADING(psf) SPACING- 2-0-0 CS1. DEFL. in ([cc) I/de I Ud PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.27 Vert(LL) -0.04 6-7 >99 480 MT20 244/190 TCDL 10.0 - Lumber DOL 1.00 BC 0.63 Vert(TL) -0.06 6-7 >99 360 BCLL 0.0 Rep Stress Incr NO WB 0.88 Horz( L) 0.00 5 n/ n/a BCDL 5.0 Code FBC2010/TPI2007 ' (Matrix-M) Weight: 88 lb FT = 0% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x6 SP No.2 5) Recommend 2x6 strongbacks, on edge, spaced at WEBS 2x4 SP No.3 `Except' 10-0-0 cc and fastened to each truss with 3-10d (0.131" W1: 2x6 SP No.2 X 3") nails. Strongbacks to be attached to walls at their BRACING- outer ends or restrained by other means. TOP CHORD 6) Hanger(s) or other connection device(s) shall be Structural wood sheathing directly applied or 6-0-0 cc St provided sufficient to support concentrated load(s) 1804 rlins, except end verticals. lb down at 7-3-4, 837 lb down at 1-10-4, and 837 lb BOT CHORD down at `3-4-4, and 837 lb down at 5-4-4 on bottom Rigid ceiling directly applied or 10-0-0 cc bracing. chord. The design/selection of such connection devices is the responsibility of others. REACTIONS. (lb/size) 8 = 2112/0-4-0 (min. 0-1-8) LOAD CASE(S) 5 = 3753/0-4-0 (min. 0-2-3) Standard Max Grav 8 = 2112(LC 1) 1) Dead + Floor Live (balanced): Lumber Increase=1.00, 5 = 3753(LC 1) Plate Increase=1.00 Uniform Loads (plf) FORCES. (lb) Vert: 14=-210, 5-8=-10 Max. Comp./Max. Ten. - All forces 250 (lb) or less except Concentrated Loads (lb) Vert: 5=-1804(F) 9=837(F) 10=-837(F) 11=-837(F) when shown. TOP CHORD 1-8=-1807/0, 1-2=-3335/O, 2-3=3335/0, 3-4=-3230/0, 4-5=-1747/0 BOT CHORD 7-10=0/3230, 6-10=0/3230 WEBS 4-6=0/3568, 1-7=0/3684, 3-6=-571/0, 2-7=-486/0 NOTES- 1) 2-ply truss to be connected togetherwith 10d (0.131"x3") nails as follows: Top chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 cc, 2x4 - 1 row at 0-9-0 cc. Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 cc. Webs connected as follows: 2x4 - 1 row at 0-9-0 cc. 2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. Julius Lee, P-E. #34869 — 11O91Coastal Bay — Boynton Beach, FL 33435 Job Truss Truss Type t } Qty Ply A0134349 59941 FG25 FLOOR 1 1 Job Reference o donal Al ROOF TRUSSES, FORT PIERCE, FL 34946 7.600 s Oct 3 2014 MiTek Industries, Inc. Fri Nov 07 09:12:20 2014 Page 1 ID:M BgdRulfexy Wo i5_CtkLoayLvGV-bKEdRa FgSfD77 NXVHsM QJ_gdNsiN PX5MZO kp_myLdsi 2-10-8 2-10-8 1.5x4 11 1 3x6 = 2 4 1'.5x4 11 3 3x6 = LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud TCLL 40.0 Plate Grip DOL 1.00 TC 0.47 Vert(LL) 0.00 4 **** 480 TCDL 10.0 Lumber DOL 1.00 BC 0.02 Vert(fL) -0.00 3-4 >999 360 BCLL 0.0 Rep Stress Incr NO WB 0.00 Horz(TL) -0.00 3 n/a n/a BCDL 6.0 Code FBC2010/TP12007 (Matrix-M) LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x6 SP No.2 *Except* W2: 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 2-10-8 oc purlins, except end verticals. BOT'CHORD Rigid ceiling direcfly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers'and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 4 = 266/Mechanical 3 = 266/Mechanical Max Grav 4 = 266(LC 1) 3 = 266(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-4=-254/0, 2-3=-254/0 NOTES- 1) Plates checked for a plus or minus 0 degree rotation about its center. 2) Refer to girder(s) for truss to truss connections. 3) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 4) Recommend 2x6 stongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. LOAD CASE(S) Standard 1) Dead + Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 1-2=-210, 3-4=-10 ALT 24" STRAP 4-10DX1.5" EACH END PLATES GRIP MT20 244/190 Weight: 16 lb FT = 0% Julius Lee, P_E. #34869— 1109 Coastal Bay — Boynton Beach. FL 33435 Job Truss Truss Type 1 Qty Ply A0134350 59941 FL01 FLOOR 7 1 J b Reference o Gonal Al KUUF I KUbbtb, NJK I VItKL:t, rL 44W40 0-3-8 Hi 2-6-0 1� ", rill R`:NO 22 21 20 4x8 = 3x6 FP= LOADING(psf) SPACING- 2-0-0 TCLL 40.0 Plate Grip DOL 1.00. TCDL 10.0 Lumber DOL 1.00 BCLL 0.0 Rep Stress Incr YES BCDL 5.0 Code FBC201 O/TP12007 LUMBER - TOP CHORD 2x4 SP No.2(flat) BOT CHORD 2x4 SP M 30(flat) WEBS 2x4 SP No.2(flat) BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (Ib/size) 1 = 1068/0-3-0 (min. 0-1-8) 13 = 1068/0-3-0 (min. 0-1-8) Max Gray 1 = 1068(LC 1) 13 = 1068(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1614/0, 2-3=-1609/0, 3-4=1609/0, 4-5=-3252/0, 5-6=-3252/0, 6-7=-3334/0, 7-8=-3252/0, 8-9=-3252/0, 9-10=-3252/0, 10-11 =-1 609/0, 11-12=-1609/0, 12-13=-1614/0 BOT CHORD 20-21=0/2658, 19-20=0/2658, 18-19=0/3334, 17-18=0/3334, 16-17=0/3334, 15-16=0/2658 WEBS 1-21=0/1847, 4-21 =-1 224/0, 4-19=0/693, 5-19=-270/101, 6-19=-571/250, 13-15=0/1847, 10-15=-1224/0, 10-16=0/693, 8-16=-270/101,7-16=-571/250 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) All plates are 1.5x4 MT20 unless otherwise indicated. 3) The solid section of the plate is required to be placed over the splice line at joint(s) 20. - 4) Plates) atjoint(s) 22, 14, 1, 9, 2, 12, 13, 18, 6, 17, 7, 21, 3, 4, 19, 5, 15, 11, 10, 16 and 8 checked for a plus or minus 0 degree rotation about its center. 5) Plate(s) at joint(s) 20 checked for a plus or minus 5 degree rotation about its center. 6) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 7.6001 s Oct 3 2014 MiTek Industries, Inc. Fri Nov 07 09:12:20 2014 Page 1 o� o e 41 I oH8 Dead Load Defl. = 1/8 in 3x3 = 3x3 = 3x3 = 3 6 FP- 3x3 = 5x6 = 5 6 7 8 9 10 11 12 13 19 18 17 16 15 14 3x6 = 3x6 = 4x8 = 19-10-0 2 - -8 19-6-8 3 8 CSI. DEFL. in (loc) Ilde L/d PLATES GRIP TC 0.61 Vert(LL)-0.2117-18 >99 480 MT20 2441190 BC 0.71 Vert(TL)-0.3417-18 >68 360 WB 0.52 Horz(TL) -0.07 13 n/ n/a (Matrix) Weight: 110 lb FT = 0%F, 0%E 7) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 8) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. LOAD CASE(S) Standard Julius Lee, P.E. 4434869- 110, ilCoastal Bay - Boynton Beach, FL 33435 Job Truss Truss Type t } Qty Ply A0134351 59941 FL02 FLOOR 1 1 Jab Reference (optional) Al KUUF i KUSStS, F-UX I NItFiGt, hL 3484ti 0-3-8 H , 2-6-0 5x6 = 3x3 = 1.5x4 11 7.600 s Oct 3 2014 MiTek Industries, Inc. Fri Nov 07 09:12:21 2014 Page 1 ID:M8gdRulfexyWoi5_CtkLoayLvGV-3Wo?fwGSDyM_IW6irZtfsBh khG�p�vg8lm Wo2UMXCyLdst 2' 2�� '2-0-0 ' 2-1-1 5 r-1 Dead Load Defl. = 1/8 in 1.5x4 II 34 = 1.5x4 11 1.5x4 11 3x3 = 3x6 FP= 3x3 = 5x6 — 18 17 16 .15 14 13 12 1.5x4 11 3x8 = 3x6 FP-- 3x3 = 3x3 = 3x8 = 1.5x4 11 LOADING(psf) TCLL 40.0 TCDL 10.0 BCLL 0.0 BCDL 5.0 SPACING- 2-0-0 Plate Grip DOL 1.00 Lumber DOL 1.00 Rep Stress Incr YES Code FBC20101TP12007 CSI. TC 0.75 BC 0.90 WB 0.45 (Matrix) LUMBER - TOP CHORD 2x4 SP No.2(flat) BOT CHORD 2x4 SP No.2(flat) WEBS 2x4 SP No.2(flat) LOAD CASE(S) BRACING- Standard TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1 = 932/0-3-0 (min. 0-1-8) 11 = 932/0-6-0 (min. 0-1-8) Max Grav 1 = 932(LC 1) 11 = 932(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1386/0, 2-3=-1382/0, 3-4=1382/0, 4-5=-2548/0, 5-6=-2548/0, 6-7=2548/0, 7-8=-1382/0, 8-9=-1382/0, 9-1 0=-1 382/0, 10-11=-1386/0 . BOT CHORD 16-17=0/2195, 15-16=0/2195, 14-15=0/2548, 13-14=012195 WEBS 1-17=0/1586, 11-13=0/1586, 4-17=-949/0, 7-13=-949/0, 4-15=0/639, 7-14=0/639, 5-15=-264/0, 6-14=-264/0 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. DEFL. in (loc) I/deft L/d Vert(LL)-0.2415-17 >852 480 Vert(TL)-0.3515-17 >589 360 Horz(TL) -0.05 11 n/a n/a pis PLATES GRIP MT20 244/190 Weight: 94 lb FT = 0%F, 0%E Julius Lee, P.E_ #34869— 1109 Coastal Bay— Boynton Beach, FL 33435 Job Truss Truss Type Qty Ply A0134352 59941 FL03. FLOOR 1 1 J b Reference o tional Al ROOF TRUSSES, FORT PIERCE, FL 34946 7.600 Is Oct 3 2014 MiTek Industries, Inc. Fri Nov 07 09:12:21 2014 Page 1 -� ID:M8gdRulfexyWoi5 CtkLoayLvGV-3Wo?fwGSDyM_IW6irZifsBhnEGvn8J?Wo2UMXCyLdst 0-3-8 2-6-0 PL-1 2-0-0 i P---i 1.5x4 II 1.5x4 II 4x6 11 3x3 = 1.5x4 11 3x4 11 3x4 11 1.5x4 11 3x3 = 4x6 11 1 2 3 4 5 6 7 8 9 10 11 16 15 14 13 12 1.5x4 11 3x6 = 3x4 11 3x4 11 3x6 = 1.5x4 11 3 13-10-13 14-5- -31 13-7-5 0-6-8 Plate Offsets X Y -- 1:0-3-0 Ede 10:0-3-0 Ede 12:0-2-0 Ede 15:0-2-8 Ed e LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/dL/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.52 Vert(LL)-0.0914-15 >99�9" 480 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0.52 Vert(TL)-0.1214-15 >99) 360 BCLL 0.0 Rep Stress Incr YES WB 0.34 Horz(TL) -0.02 10 n n/a BCDL 5.0 Code FBC2010/TP12007 (Matrix) Weight: 80 lb FT = 0%F, 0%E LUMBER - TOP CHORD 2x4 SP No.2(flat) BOT CHORD 2x4 SP No.2(flat) WEBS 2x4 SP No.2(flat) BRACING - TOP CHORD Structural woad sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1 = 742/0-3-0 (min. 0-1-8) 10 = 742/0-6-0 (min. 0-1-8) Max Gray 1 = 742(LC 1) 10 = 742(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1060/0, 2-3=-1056/0, 3-4=1056/0, 4-5=-1600/0, 5-6=-1600/0, 6-7=1600/0, 7-8=-1056/0, 8-9=-1056/0, 9-10=-1060/0 BOT CHORD 14-15=0/1559, 13-14=0/1600, 12-13=0/1559 WEBS 1-15=0/1212, 3-15=-262/0, 10-12=0/1212, 8-12=-263/0, 4-15=-587/0, 7-12=-587/0, 4-14=-138/463, 7-13=-138/463, 5-14=-376/115, 6-13=-376/115 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.5001n. LOAD CASE(S) Standard Julius Lee, P.E. #34869 — 110 Coastal Bay — Boynton Beach, FL 33435 Job Truss Truss Type t Qry Ply A0134353 59941 FL04 FLOOR 1 1 Job Reference (optional) Al ROOF TRUSSES, FORT PIERCE, FL 34946 7.600 s Oct 3 2014 MiTek Industries, Inc. Fri Nov 07 09:12:22 2014 Page 1 I D:M8 gd Rulfexy Woi 5_CtkLoayLvGV-YiM N sGH5_G UrN ghu P GOu PP E?hfH3tnxt0iDw3eyLd=_ 0-3-8 I —I 2-6-0 26 ' 2-Q-0 2-6 0-6-8� 46 11 3x3 = 1.5x4 11 3x3 = 1.5x4 11 3x3 = 4x6 11 1 2 3 4 5 3x3 = 6 7 8 .2 U ? 14 13 12 11 10 9 1.5x4 11 3x6 = 1.5x4 11 1.5x4 11 3x6 = 1.5x4 11 LOADING(psf) SPACING- 2-0-0 TCLL 40.0 Plate Grip DOL 1.00 TCDL 10.0 Lumber DOL 1.00 BCLL 0.0 Rep Stress Incr YES BCDL 5.0 Code FBC2010/TP12007 LUMBER - TOP CHORD 2x4 SP No.2(flat) BOT CHORD 2x4 SP No.2(flat) WEBS 2x4 SP No.2(flat) BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1 = 551/0-3-0 (min. 0-1-8) 8 = 551/0-6-0 (min. 0-1-8) Max Grav 1 = 551(LC 1) 8 = 551(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-725/0, 2-3=-720/0, 3-4=-720/0, 4-5=-872/0, 5-6=-721 /0, 6-7=-721 /0, 7-8=-725/0 BOT CHORD 12-13=0/872, 11-12=0/872, 10-11=0/872 WEBS 1-1 3=0/827, 8-1 0=01827, 4-13=-361 /0, 5-10=-361 /0 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131 " X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. LOAD CASE(S) Standard CSI. DEFL. in (loc) I/deft Ud TC 0.35 Vert(LL) -0.0412-13 >999 480 BC 0.39 Vert(TL) -0.05 12 >999 360 WB 0.23 Horz(TL) -0.01 8 n/a n/a (Matrix) PLATES GRIP MT20 244/190 Weight: 63 lb FT = 0%F, 0%E 0 Julius Lee, P_E_ #34869— 1109. Coastal Bay— Boynton Beach, FL 33435 Job Truss Truss Type 1, Qty Ply 59941 FL05 FLOOR 1 1 Ub A0134354 Reference (optional) Al KUUr I KU55t6, FUK I rltKUl=, rL J4V4b 10 1.5x4 II 7.600 is Oct 3 2014 MiTek Industries, Inc. Fri Nov 07 09:12:22 2014 Page 1 yWoi CtkLoayLvGV-YiMNsGH5_GUrNghuPGOuPPE_FfKDtoaf0iDw3eyLds 2-6-0 , 1-2-3 , 3x3 = 1.5x4 11 1.5x4 11 2 3 4 5 3x3 = 9 8 3x3 = 1 0-�� 3x3 = 3x6 11 6 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/d fl Ud TCLL 40.0 Plate Grip DOL 1.0a TC 0.44 Vert(LL) -0.03 7-8 >9 9 480 TCDL 10.0 Lumber DOL 1.00 BC 0.25 Vert(TL) -0.04 7-8 >9 9 360 BCLL 0.0 Rep Stress Incr YES WB 0.13 Horz(TL) -0.00 6 n a n/a BCDL 5.0 Code FBC2010/TPI2007 (Matrix) LUMBER - TOP CHORD 2x4 SP No.2(flat) BOT CHORD 2x4 SP No.2(flat) WEBS 2x4 SP No.2(flat) BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (Ib/size) 1 = 361/0-3-0 (min. 0-1-8) 6 = 361/0-6-0 (min. 0-1-8) Max Grav 1 = 361(LC 1) 6 = 361(LC 1) FORCES. (lb) Max. Camp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-403/0, 2-3=-398/0, 3-4=-398/0, 4-5=-398/0, 5-6=-403/0 BOT CHORD 8-9=0/398 WEBS 6-8=0/457, 1-9=0/457 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. LOAD CASE(S) Standard 7 1.5x4 II PLATES GRIP MT20 244/190 Weight: 43 lb FT = 0%F, 0%E Julius Lee, P.E. #34869— 110!p Coastal Bay — Boynton Beach, FL 33435 Job Truss Truss Type s Qty Ply A0134355 59941 FL FLOOR 1 1 Job Reference (optional) Al ROOF I-RUSSt5, FUR I NItKGt, FL 34y4ti 0-3-8 3x611 3x611 �_� , 1-5-1 2 7.600 s Oct 3 2014 MiTek Industries, Inc. Fri Nov 07.09:12:22 2014 Page 1 ID:M8gdRulfexyWoi5_CtkLoayLvGV-YiMNsGH5_GUrNghu PGOuPPE4UfN?tgxfOiDw3eyLds 3x6 II 3 , 1.5x4 11 3x6 = 1.5x4 11 0-3F8, 1-10-1 51r11r9 __ 3-e2 4 4-0-10 0-3-8 1-6-9 - 0-1-b 1-6-9 10-6-8 ' LOADING(psf) SPACING- 2-0-0 CSI. DEFL, in (loc) I/deft L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.04 Vert(LL) -0.00 5 >999 480 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0.01 Vert(TL) -0.00 5 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.04 Horz(TL) -0.00 3 n/a n/a BCDL 5.0 Code FBC201 O/TP12007 (Matrix) Weight: 28 lb FT = O%F, O%E LUMBER - TOP CHORD 2x4 SP No.2(flat) BOT CHORD 2x4 SP No.2(flat) WEBS 2x4 SP No.2(flat) BRACING - TOP CHORD Structural wood sheathing directly applied or 4-0-10 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1 = 170/0-3-0 (min.0-1-8) 3 = 170/0-6-0 (min.0-1-8) Max Grav 1 = 170(LC 1) 3 = 170(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Plates checked for a plus or minus 0 degree rotation about its center. 2) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-1 Od (0.131 " X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. LOAD CASE(S) Standard Julius Lee, P_E_ #34869— 1109 Coastal Bay— Boynton Beach, FL 33435 Job Truss Truss Type Y Qty Ply 59941 FL07 FLOOR 6 1 A0134356 Job Reference (optional) Al ROOF TRUSSES, FORT PIERCE, FL 34946 7.60 s Oct 3 2014 MiTek Industries, Inc. Fri Nov 07 09:12:23 2014 Page 1 ID:M8gdRulfexy of5_CtkLoayLvGV-0vwl4cljlaci_gG4y_w7xcn8Z3egcFNoFMzTb5yLds: 0-3-8 �i , 2-6-0 2-0-0 5 2-5-10 3x6 11 3x3 = 1.5x4 11 3x3 11 1 2 3 4 3x3 5 9 8 7 6 1.5x4 11 3x3 = 1.5x4 11 3x6 = LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) 1/d A L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.47 Vert(LL) -0.05 6-7 >9 39 480 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0.36 Vert(TL) -0.06 6-7 >9 39 360 BCLL 0.0 Rep Stress Incr YES WB 0.16 Horz(TL) 0.02 6 r /a n/a BCDL 5.0 Code FBC2010/TP12007 (Matrix) Weight: 44 lb FT = 0%F, 0%E LUMBER - TOP CHORD 2x4 SP No.2(flat) BOT CHORD 2x4 SP No.2(flat) WEBS 2x4 SP No.2(flat) BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 cc pudins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (Ib/size) 6 = 407/Mechanical 1 = 407/0-3-0 (min. 0-1-8) Max Grav 6 = 407(LC 1) 1 = 407(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-491/0, 2-3=-486/0, 3-4=-486/0 BOT CHORD 7-8=0/486, 6-7=0/486 WEBS 1-8=0/558, 4-6=-562/0 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) Refer to girder(s) for truss to truss connections. 4) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 5) Recommend 2x6 stongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.5001n. 7) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard Julius Lee, P.E. #34869— 1101) Coastal Bay— Boynton Beach, FL 33435 Job Truss Truss Type i Qty Ply 59941 FL21 G FLOOR 1 2 A0134357 Job Reference o tiorial Al ROOF TRUSSES, FORT PIERCE, FL 34946 7.600 s Oct 3 2014 MiTek Industries, Inc. Fri Nov 07 09:12:23 2014 Page 1 I D: M8gd Rulfexy Wo i5_CtkLoayLvG V-0vwl4cljlaci_gG4y_w7xcn9m3ZFc2PoFMzTb5yLds., 0-3-8 2-6-0 I0 9�1' 0 fad oH8 Dead Load Dell. = 1/8 in 5x6 = 3x6 11 1.5x4 11 1.5x4 11 3x6 FP= 3x6 11 5x6 — II uu ,. I I Rod /. /...\ III Ayli:/ I1 uu�����roo� \ I� I I �I� I 1 22 21 20 19 18 17 16 15 14 1.5x4 11 3x6 = 3x6 FP= 3x6 =1.5x4 11 1.5x4 11 3x6 = 4x8 = 1.5x4 11 Or3T8 19-10-0 2q-1-8 rL4_A 1 as. -A n-3-R Ici Plate Offsets (X Y)—f1:0-1-8 Edge], f13:0-1-8 Edge], [15:0-2-12,Edge], f21:0-2-8 Edgel LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.39 Vert(LL) -0.18 17 >999 480 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0.65 Vert(TL) -0.28 17 >845 360 BCLL 0.0 Rep Stress Incr NO WB 0.99 Horz(TL) -0.04 13 n/a n/a BCDL 5.0 Code FBC2010/TPI2007 (Matrix) Weight: 234 lb FT = 0%F, 0%E LUMBER - TOP CHORD 2x4 SP M 30(flat) *Except* T1: 2x4 SP No.2(flat) BOT CHORD 2x4 SP M 30(flat) WEBS 2x4 SP No.3(flat) BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1 = 1214/0-3-0 (min. 0-1-8) 13 = 2430/0-3-0 (min.0-1-8) Max Grav 1 = 1214(LC 1) 13 = 2430(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-2179/0, 2-3=-2184/0, 3-4=-2179/0, 4-5=-4460/0, 5-6=-4460/0, 6-7=4766/0, 7-8=-4903/0, 8-9=-4903/0, 9-10=4903/0, 10-1 1=-3710/0,11-23=-371110, 12-23=-3728/0, 12-13=3710/0 BOT,CHORD 20-21=0/3517, 19-20=0/3517, 18-19=0/4766, 17-18=014766, 16-17=0/4766, 15-16=0/4473 WEBS 6-18=-131/330, 7-17=-343/119, 2-21=-325/0, 4-21=-1518/0, 4-19=0/1071, 5-19=-268/209, 6-19=-989/157, 1-21=0/2436, 12-15=-1407/0, 10-15=-866/0, 10-16=0/640, 8-16=-405/75, 7-16=-474/675, 13-15=0/4148 NOTES- 1) Fasten trusses together to act as a single unit as per standard industry detail, or loads are to be evenly applied to all plies. 2) Unbalanced floor live loads have been considered for this design. 3) All plates are 3x3 MT20 unless otherwise indicated. 4) Plates checked for a plus or minus 0 degree rotation about its center. 5) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this 6) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 7) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead +.Floor Live (balanced): Lumber Increase=1.00, Plate Increase=1.00 Uniform Loads (plf) Vert: 14-22=10, 1-23=100, 13-23=-500(F=-400) Julius Lee, P.E. #34869— 1109 Coastal Bay — Boynton Beach, FL 33435 Job Truss Truss Type % Qty Ply 59941 FL22 Floor g 1 lob A0134358 Reference (optional) Al ROOF I RUSSES, FOR I PILRUE, FL 34946 0-3-8 H 2H-60 k 22 21 20 48 = 3x6 FP= LOADING(psf) SPACING- 2-0-0 TCLL 40.0 Plate Grip DOL 1.00 TCDL 10.0 Lumber DOL 1.00 BCLL 0.0 Rep Stress Incr YES BCDL 5.0 Code FBC2010lrP12007 LUMBER - TOP CHORD 2x4 SP M 30(flat) *Except* Ti: 2x4 SP No.2(flat) SOT CHORD 2x4 SP M 30(flat) WEBS 2x4 SP No.3(flat) BRACING - TOP CHORD Structural wood sheathing directy applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1 = 1068/0-3-0 (min. 0-1-8) 13 = 1068/0-3-0 (min. 0-1-8) Max Grav 1 = 1068(LC 1) 13 = 1068(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1806/0, 2-3=-1802/01' 34=1802/0, 4-5=-3645/0, 5-6=-3645/0, 6-7=3735/0, 7-8=-3645/0, 8-9=-3645/0, 9-10=-3645/0, 10-11=-1802/0, 11-12=-1802/0, 12-13=-1806/0 BOT CHORD 20-21=0/2978, 19-20=0/2978, 18-19=0/3735, 17-18=0/3735, 16-17=0/3735, 15-16=0/2978 WEBS 1-21=0/2014, 4-21 =- 1335/0, 4-19=01756, 5-19=-280/111, 6-19=-589/258, 13-15=0/2014, 10-1 5=-1 335/0, 10-16=0/756, 8-16=-280/111, 7-16=-589/258 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) All plates are 1.5x4 MT20 unless otherwise indicated. 3) The solid section of the plate is required to be placed over the splice line at joint(s) 20. 4) Plate(s) at joint(s) 22, 14, 1, 9, 2, 12, 13, 18, 6, 17, 7, 21, 3, 4, 19, 5, 15, 11, 10, 16 and 8 checked for a plus or minus 0 degree rotation about its center. 5) Plate(s) at joint(s) 20 checked for a plus or minus 5 degree rotation about its center. 6) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this /.6UU S UCt 3 ZU14 MI I eK 3x4 = 3x3 = 3x3 = x6 FP-- 5 6 7 8 1 9 10 19 18 17 16 3x6 = 3x6 = Inc. Fri Nov 07 09:12:24 2014 Page 1 _r HWhRMUgJL1Tu9LW5yUOi17XyLds1 oH8 Dead Load Defl. = 1 /8 in 3x3 = 5x6 = 12 13 15 14 48 = 19-6-8 -318 Ede 21:0-3-12 Ed e CSI. DEFL. in (loc) Ik efl L/d PLATES GRIP TC 0.36 Vert(LL)-0.2517-18 > 46 480 MT20 244/190 BC 0.74 Vert(TL)-0.3917-18 > 00 360 WB 0.96 Horz(TL) -0.07 13 1 /a n/a (Matrix) Weight: 107 lb FT = O%F, 0%E 7) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-1 Od (0.13 " X 3") nails. Strongbacks to be attached to walls at thei outer ends or restrained by other means. 8) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. LOAD CASE(S) Standard Julius Lee, P.E_ #34869 - 111J9 Coastal Bay - Boynton Beach, FL 33435 Job Job Truss Truss Type s Qty Ply A0134359 FL23 Floor 1 1 Job Reference (optional Al ROOF TRUSSES, FORT PIERCE, FL 34946 7.600 s Oct 3 2014 MiTek Industries, Inc. Fri Nov 07 09:12:24 2014 Page 1 ID:M8gdRulfexyWoi5_CtkLoayLvGV-U5U7HyJLWtkZc_rHWhRMUgJEITsLLXEyUOi 17XyLdsi 0-6-8 H' 2-6-0�'��4i 118 Dead Load Defl. = 1/8 in 5x6 = 3x3 = 1.5x4 11 3x4 = 1.5x4 11 3x3 =1.5x4 11 3x6 FP= 3x3 = 1.5x4 11 3x3 = 5x6 = 9 q d e R 7 R 9 10 11 12 20 19 18 17 16 15 14 13 1.5x4 11 48 = 3x6 FP= 3x4 = 1.5x4 11 3x6 = 48 = 1.5x4 11 LOADING(psf) SPACING- 2-0-0 TCLL 40.0 Plate Grip DOL 1.00 TCDL 10.0 Lumber DOL 1.00 BCLL 0.0 Rep Stress Incr YES BCDL 5.0 Code FBC2010/TPI2007 LUMBER - TOP CHORD 2x4 SP No.2(flat) BOT CHORD 2x4 SP No.2(flat) *Except* B2: 2x4 SP M 30(flat) WEBS 2x4 SP No.3(flat) BRACING - TOP CHORD Structural wood sheathing directly applied or 5-2-3 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1 = 996/0-6-0 (min. 0-1-8) 12 = 996/0-3-0 (min. 0-1-8) Max Gray 1 = 996(LC 1) 12 = 996(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1667/0, 2-3=-1662/0, 3-4=1662/0, 4-5=-3223/0, 5-6=-3223/0, 6-7=3244/0, 7-8=-3244/0, 8-9=-3244/0, 9-10=-1664/0, 10-11 =-1 664/0, 11-12=-1669/0 BOT CHORD 18-19=0/2700, 17-18=0/2700, 16-17=0/3223, 15-16=0/3223, 14-15=0/2707 WEBS 5-17=-279/0, 6-16=-255/114, 1-19=0/1859, 4-19=-1177/0,4-17=0(796,12-14=0/1861, 9-14=-1183/0, 9-15=0/610, 7-15=-317/85, 6-15=-465/410 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) The solid section of the plate is required to be placed over the splice line at joint(s) 18. 3) Plate(s) at joint(s) 20, 13, 1, 8, 2, 11, 12, 17, 5, 16, 6, 19, 3, 4, 14, 10, 9, 15 and 7 checked for a plus, or minus 0 degree rotation about its center. 4) Plate(s) at joint(s) 18 checked for a plus or minus 5 degree rotation about its center. 5) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. CSI. DEFL. in (loc) I/deft TC 0.79 Vert(LL) -0.2415-16 >915 BC 0.85 Vert(fL) -0.3615-16 >600 WB 0.89 Horz(TL) -0.07 12 n/a (Matrix) 6) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 7) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. LOAD CASE(S) Standard 19-0,12 Ud PLATES GRIP 480 MT20 244/190 360 n/a Weight: 100 Ib FT = 0%F, 0%E Julius Lee, P.E_ #34869- 1109 Coastal Bay - Boynton Beach, FL 33435 Job Truss Truss Type 4 Qty Ply 59941 FL24 Floor 1 1 A0134360 �1.b Reference o tional Hl KUUr I KUOOLO, rUK I VICKUC, rL d4`J40 0-6-8 [ I I 2-6-0 5x6 = 3x3 = 1.5x4 11 1 2 3 16 15 1.5x4 II 3x8= i 1-0-1� 1 2-0-0 i 1-0-1� 3x3 = 1.5x4 11 4 5 LOADING(psf) SPACING- 2-0-0 CSI. TCLL 40.0 Plate Grip DOL 1.00 TC 0.60 TCDL 10.0 Lumber DOL 1.00 BC 0.67 BCLL 0.0 Rep Stress Incr YES WB 0.69 BCDL 5.0 Code FBC2010/TP12007 (Matrix) LUMBER - TOP CHORD 2x4 SP No.2(flat) BOT CHORD 2x4 SP No.2(flat) WEBS 2x4 SP No.3(flat) BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1 = 805/0-6-0 (min.0-1-8) 10 = 805/0-3-0 (min. 0-1-8) Max Grav 1 = 805(LC 1) 10 = 805(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1309/0, 2-3=-1305/0, 3-4=1305/0, 4-5=-2116/0, 5-6=-2116/0, 6-7=2116/0, 7-8=-1305/0, 8-9=-1305/0, 9-10=-1309/0 BOT CHORD 14-15=0/1979, 13-14=0/2116, 12-13=0/1979 WEBS 1-15=0/1459, 3-15=-255/0, 10-12=0/1459, 8-12=-255/0, 4-15=-765/0, 7-12=-765/0, 4-14=-31/465,7-13=-31/465, 5-14=-291/4, 6-13=-291 /4 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. LOAD CASE(S) Standard 14 3x3 = 7.609 s Oct 3 2014 MiTek Industries, Inc. Fri Nov 07 09:12:25 2014 Page 1 Woi_CtkLoayLvGV-yH1WU]JzGBsQE8QT4Pyb01sR2tFQ41U5igSagzyLdsc 1.5x4 11 3x3 = 6 7 13 3x3 = 1.5x4 11 3x3 = 5x6 = 8 9 10 12 11 3x8 = 1.5x4 11 DEFL. in (loc) 1/ efl Ud PLATES GRIP Vert(LL)-0.1412-13 > 99 480 MT20 244/190 Vert(TL)-0.2012-13 > 76 360 Horz(TL) -0.03 10 /a n/a Weight: 82 lb FT = 0%F, 0%E Julius Lee, P.E. #34869— 1109 Coastal Bay — Boynton Beach, FL 3343S Job Truss Truss Type v Qty Ply A0134361 59941 FL25 Floor 1 1 Jab Reference (optional) Al ROOF TRUSSES, FORT PIERCE, FL 34946 7.600 s Oct 3 2614 MiTek Industries, Inc. -Fri Nov 07 09:12:25 2014 Page 1 ID:M8gdRulfexyWoi5_CtkLoayLvGV-yH1 WUIJzGBsQE8QT4Pyb01sU8tHu44b5igSagzyLdsc 0-6-8 2-6-0 1-9=5 2-0-0 1-9-5 T - 11 4x6 11 3x3 = 1.5x4 11 3x3 = 1.5x4 11 3x3 = 4x6 11 1 2 3 4 53x3 = 6 7 8 14 13 12 11 10 9 1.5x4 11 3x6 = 1.5x4 11 1.5x4 11 3x6 = 1.5x4 11 LOADING(psf) SPACING- 2-0-0 TCLL 40.0 Plate Grip DOL 1.00 TCDL 10.0 Lumber DOL 1.00 BCLL 0.0 Rep Stress Incr YES BCDL 5.0 Code FBC2010/TP12007 LUMBER - TOP CHORD 2x4 SP No.2(flat) BOT CHORD 2x4 SP No.2(flat) WEBS 2x4 SP No.3(flat) BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1 = 615/0-6-0 (min. 0-1-8) 8 = 615/0-3-0 (min. 0-1-8) Max Grav 1 = 615(LC 1) 8 = 615(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-934/0, 2-3=-930/0, 3-4=-930/0, 4-5=-1225/0, 5-6=-930/0, 6-7=-930/0, 7-8=-934/0 BOT CHORD 12-13=0/1225, 11-12=0/1225, 10-11=0/1225 WEBS 1-13=0/1040, 3-13=258/10, 8-10=0/1039, 6-10=-258/10, 4-13=-480/0, 5-10=-480/0 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 cc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. LOAD CASE(S) Standard tv I CSI. DEFL. in (loc) I/deft L/d TC 0.40 Vert(LL)-0.0710-11 >999 480 BC 0.51 Vert(TL)-0.0910-11 >999 360 WB 0.50 Horz(TL) -0.01 8 n/a n/a (Matrix) PLATES GRIP MT20 244/190 Weight: 65 lb FT = 0%F1 0%E Julius Lee, P-E. #34869— 1109 Coastal Bay — Boynton Beach, FL 33435 Jab Truss Truss Type a Qty Ply 59941 FL26 Floor 1 1 A0134362 ob Reference o tional Al ROOF TRUSSES, FORT PIERCE, FL 34946 7.60 s Oct 3 2014 MiTek Industries, Inc. Fri Nov 07 09:12:25 2014 Page 1 ID:M8gdRulfexyWoi CtkLoayLvGV-yH1WUIJzGBsQE8QT4Pyb01sUBtKE47Y5igSagzyLdsi 0-6-8 i 2-6-0 2-4-1 P:34 4x6 11 3x3 = 1.5x4 11 1.5x4 11 3x3 = 46 11 1 2 3 4 5 6 oS 10 9 8 3x3 — 7 1.5x4 11 3x3 = 1.5x4 11 0-6-8 8-4-9 -8- 0-6-8 7-10-1 -3- LOADING(psf) TCLL 40.0 TCDL 10.0 BCLL 0.0 BCDL 5.0 SPACING- 2-0-0 Plate Grip DOL 1.00 Lumber DOL 1.00 Rep Stress Incr YES Code FBC2010/TP12007 CSI. TC 0.40 BC 0.36 WB 0.31 (Matrix) DEFL. in (loc) Ik Vert(LL) -0.05 7-8 > Vert(TL) -0.06 9-10 -> Horz(TL) -0.00 6 efl Ud 99 480 99 360 /a n/a PLATES GRIP MT20 244/190 Weight: 45 lb FT = 0%F, 0%E LUMBER - TOP CHORD 2x4 SP No.2(flat) BOT CHORD 2x4 SP No.2(flat) WEBS 2x4 SP No.3(flat) BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1 = 424/0-6-0 (min. 0-1-8) 6 = 424/0-3-0 (min. 0-1-8) Max Grav 1 = 424(LC 1) 6 = 424(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-581/0, 2-3=-576/0, 3-4=-576/0, 4-5=-576/0, 5-6=-581/0 BOT CHORD 8-9=0/576 WEBS 1-9=0/644, 3-9=-261/0, 6-8=0/644, 4-8=-261/0 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 cc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. LOAD CASE(S) Standard Julius Lee, P.E. #34869— 11p9 Coastal' Bay — Boynton Beach, FL 33435 Job Truss Truss Type + Qty Ply A0134363 59941 FL27 Floor 1 1 Job Reference (optional) Al ROOF TRUSSES, FORT PIERCE, FL 34946 7.600 s Oct 3 2014 MiTek Industries, Inc._ Fri Nov 07 09:12:26 2014 Page 1 ID:M8gdRulfexyWoi5_CtkLoayLvGV-QUbuidKblV Hrl_fe6TgZFPknHllpdbFxKB7CQyLdsp 0-6-8 2-0-0 , 0-3-8 3x6 11 3x6 11 3x6 I I 1 2 3 3x6 = 6 5 4 1.5x4 II 1.5x4 II LOADING(psf) TCLL 40.0 TCDL 10.0 BCLL 0.0 BCDL 5.0 SPACING- 2-0-0 Plate Grip DOL 1.00 Lumber DOL 1.00 Rep Stress Incr YES Code FBC2010/TPI2007 CSI. TC 0.09 BC 0.02 VC 0.13 (Matrix) DEFL. in (loc) I/deft Ud Vert(LL) -0.00 5 >999 480 Vert(TL) -0.00 5-6 >999 360 Horz(TL) -0.00 3 n/a n/a PLATES GRIP MT20 244/190 Weight: 34 lb FT = 0%F, 0%E LUMBER - TOP CHORD 2x4 SP No.2(flat) BOT CHORD 2x4 SP No.2(flat) WEBS 2x4 SP No.3(flat) BRACING - TOP CHORD Structural wood sheathing directly applied or 5-2-8 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1 = 23410-6-0 (min. 0-1-8) 3 = 234/0-3-0 (min. 0-1-8) Max Grav 1 = 234(LC 1) 3 = 234(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-5=0/269, 1-5=0/269, 2-5=-257/0 NOTES- 1) Plates checked for a plus or minus 0 degree rotation about its center. 2) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. LOAD CASE(S) Standard Julius Lee, P.E. #34869— 1109 Coastal Bay —Boynton Beach, FL 33435 Job . Truss Truss Type Qty Ply A0134364 59941 FL28 Floor - 1 1 ob Reference (optional) Al ROOF IRUSStS, FOR HIERUE, FL 34946 ID:M8gd 0-6-8 3x611 3x611 7.60 s Oct 3 2014 MiTek Industries, Inc. Fri Nov 07 09:12:26 2014 Page 1 KyW i5_CtkLoayLvGV-QUbuidKbiV_Hri_fe6TgZFPIQH13peaFxKB7CQyLdsf 1 , 2 ' 00� f 035� 3x3 = 1.5x4 11 0-6-8 5 ^1-5-71 4 1^8^i5i LOADING(psf) SPACING- 2-0-0 CSL DEFL. in (loc) 1/1efl L/d TCLL 40.0 Plate Grip DOL 1.00 TC 0.05 Vert(LL) -0.00 5 > 99 480 TCDL 10.0 Lumber DOL 1.00 BC 0.00 Vert(TL) -0.00 5 > 99 360 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 /a n/a BCDL 5.0 Code FBC2010frPI2007 (Matrix) LUMBER - TOP CHORD 2x4 SP No.2(flat) BOT CHORD 2x4 SP No.2(flat) WEBS 2x4 SP No.3(flat) BRACING - TOP CHORD Structural wood sheathing directly applied or 1-8-15 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1 = 72/0-6-0 (min. 0-1-8) 3 = 75/0-3-0 (min.0-1-8) Max Grav 1 = 72(LC 1) 3 = 75(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Plates checked for a plus or minus 0 degree rotation about its center. 2) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 3) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131 " X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. LOAD CASE(S) Standard PLATES GRIP MT20 244/190 Weight: 12 lb FT = 0%F, 0%E Julius Lee, P.E. #34869— 1>,09 Coastal Bay — Boynton Beach, FL 33435 Job Truss Truss Type + A0134365 FL29 Floor F 759941 1 Job Reference (optional) Al KUUt- IKU66t6, t-UKI YItKUt, rL J4`J40 0-3-8 H 2-6-0 7.600 s Oct 32014 MiTek Industries, Inc. FriNov 07 09:12:27 2014 Pagel I D: M8gdRu Ifexy Woi5_CtkLoayLvGV-u g9 GvzLDoo 68TRZsBq_36Sxn VgtfYwJOA_xh ksyLdst 1I-5 2-0-0 4- Dead Load Defl. = 1/16 in 5x6 = 3x3 = 1.5x4 11 3x3 = 1.5x4 11 3x3 = 1.5x4 11 3x4 = 3x3 11 1 2 3 4 5 6 7 8 9 15 14 13 12 11 10 1.5x4 11 3x8 = 3x3 = 1.5x4 11 3x6 = 3x6 = 3-)8 15-10-10 LOADING(psf) SPACING- 2-0-0 TCLL 40.0 Plate Grip DOL 1.00 TCDL 10.0 Lumber DOL 1.00 BCLL 0.0 Rep Stress Incr YES BCDL 5.0 Code FBC2010/TP12007 LUMBER - TOP CHORD 2x4 SP No.2(flat) BOT CHORD 2x4 SP No.2(flat) WEBS 2x4 SP No.3(flat) BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling direcfly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 10 = 847/Mechanical 1 = 847/0-3-0 (min. 0-1-8) Max Grav 10 = 847(LC 1) 1 = 847(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1389/0, 2-3=-1385/0, 34=1385/0, 4-5=-2345/0, 5-6=-2345/0, 6-7=2155/0, 7-8=-2155/0 BOT CHORD 13-14=0/2137, 12-13=012345, 11-12=0/2345, 10-11=0/1378 WEBS 5-13=-254/0, 1-14=0/1548, 3-14=-252/0, 4-14=-854/0, 4-13=0/507, 8-10=-1566/0, 8-11=0/881, 6-11=-518/55 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) Refer to girder(s) for truss to truss connections. 4) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 5) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 7) CAUTION, Do not erect truss backwards. CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TC 0.60 Vert(LL) -0.1613-14 >999 480 MT20 244/190 BC 0.88 Vert(TL) -0.2513-14 >755 360 WB 0.74 Horz(TL) 0.02 10 n/a n/a (Matrix) Weight: 84 lb FT = 0%F, 0%E LOAD CASE(S) Standard Julius Lee, P.E. #34869— 1109 Coastal Bay — Boynton Beach, FL 33435 Job Truss Truss Type ► Qty Ply A0134366 59941 FL30 Floor 1 1 ob Reference (optional) Al ROOF TRUSSES, FORT PIERCE, FL 34946 7.6011 s Oct 3 2014 MiTek Industries, Inc. Fri Nov 07 09:12:27 2014 Page 1 ID:M8gdRulfexyW i5_CtkLoayLvGV-ug9GvzLDoo68TRZsBq_36SxnpgulYyYOA_xhksyLds 0-3-8 H 2-6-0 1-4-5 2-0-0 1-4-0 Dead Load Defl. = 1/8 in 5x6 = 3x3 = 1.5x4 11 3x3 = 1.5x4 11 1.5x4 11 3x3 = 34 11 1 2 3 4 5 6 7 8 MVI I V, 13 12 11 10 9 1.5x4 II 3x6 = 3x3 = 3x3 = 3x6 = 3- 13-2-13 3- 12-11-5 Plate Offsets X -- 1:0-1-8 Ed a 12:0-2-12 Ed e LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.58 Vert(LL)-0.1811-12 > 66 480 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0.77 Vert(TL)-0.2711-12 > 60 360 BCLL 0.0 Rep Stress Incr YES WB 0.59 Horz(TL) -0.02 9 /a n/a BCDL 5.0 Code FBC2010/TPI2007 (Matrix) Weight: 70 lb FT = 0%F, 0%E LUMBER - TOP CHORD 2x4 SP No.2(flat) *Except* T2: 2x4 SP M 30(flat) BOT CHORD 2x4 SP No.2(flat) WEBS 2x4 SP No.3(flat) BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 9 = 701/Mechanical 1 = 701/0-3-0 (min. 0-1-8) Max Gray 9 = 701(LC 1) 1 = 701(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1121/0, 2-3=-1116/0, 3-4=1116/0, 4-5=-1535/0, 5-6=-1535/0, 6-7=1535/0 BOT CHORD 11-12=0/1583, 10-11=0/1535, 9-10=0/1102 WEBS 6-10=-388/0, 1-12=0/1248, 4-12=-529/0, 7-9=-1244/0,7-10=0/704 NOTES- 1) Unbalanced floor live loads have been considered for this design.. 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) Refer to girder(s) for truss to truss connections. 4) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 5) Recommend 2x6 stongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131 " X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 7) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard Julius Lee, P.E_ #34869— 1 09'Coa.stal Bay —Boynton Beach, FL 33435 Job Truss Truss Type + Qty Ply 59941 FL31 Floor 1 1 1 A0134367 Job Reference (optional) Al MUUY I KUb.7t0, run 1 V IMM .t, r•L 34t340 0-3-8 H , 2-6-0 5x6 = 3x3 = 1 2 1.5x4 II 3 13 12 1.5x4 11 3x6 = LOADING(psf) SPACING- 2-0-0 TCLL 40.0 Plate Grip DOL 1.00 TCDL 10.0 Lumber DOL 1.00 BCLL 0.0 Rep Stress Incr YES BCDL 5.0 Code FBC2010/TP12007 LUMBER - TOP CHORD 2x4 SP No.2(flat) BOT CHORD 2x4 SP No.2(flat) WEBS 2x4 SP No.3(flat) BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 9 = 765/Mechanical 1 = 765/0-3-0 (min. 0-1-8) Max Grav 9 = 765(LC 1) 1 = 765(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-1238/0, 2-3=-1234/0, 34=1234/0, 4-5=-1893/0, 5-6=-1893/0, 6-7=1893/0 BOT CHORD 11-12=0/1822, 10-11=0/1893, 9-10=0/1218 WEBS 6-10=-291/0, 1-12=0/1380,3-12=-251/0, 4-12=-668/0, 4-11=-103/369, 7-9=-1376/0, 7-10=0/817 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) Refer to girder(s) for truss to truss connections. 4) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 5) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 7) CAUTION, Do not erect truss backwards. 7.600 s Oct 3 2014 MiTek Industries, Inc. Fri Nov 07 09:12:27 2014 Page 1 ID:M8gdRulfexyWoi5_CtkLoayLvGV-ug9GvzLDoo68TRZsBq_36SxkmguNYxaOA_xhksyLds- 2-0-0 2-5-14 , Dead Load Defl. = 1/16 in 3x3 = 1.5x4 11 1.5x4 11 3x4 = 3x3 11 4 5 6 7 8 CSI. TC 0.78 BC 0.83 WB 0.66 (Matrix) 11 10 3x3 = 3x4 = DEFL. in (loc) I/deft Ud Vert(LL)-0.2011-12 >817 480 Vert(TL)-0.2911-12 >580 360 Horz(TL) -0.02 9 n/a n/a 9 3x6 PLATES GRIP MT20 244/190 Weight: 75 lb FT = 0%F, 0%E LOAD CASE(S) Standard Julius Lee, P_E_ #34869 — 1109 Coastal Bay — Boynton Beach, FL 33435 Job Truss Truss Type f + Qty - Ply A0134368 59941 FL32 Floor 1 1 Lb Reference(o tional Al ROOF TRUSSES, FORT PIERCE, FL 34946 7.60p s Oct 3 2014 MiTek Industries, Inc. Fri Nov 07 09:12:28 2014 Page 1 ID:M8gdRulfexyW i5_CtkLoayLvGV-Msie7JMrZ6E_5b821XVIegU534QOHXiXPegEGlyLdsi 0-3-8 3x6 II 3x6 II 3x6 II ' 'I--i-i ' 1-�ci 3 i 6 5 4 1.5x4 II 3x3= 0-5-0 34 = LOADING(psf) SPACING- 2-0-0 CSI. TCLL 40.0 Plate Grip DOL 1.00 TC 0.04 TCDL 10.0 Lumber DOL 1.00 BC 0.04 BCLL 0.0 Rep Stress Incr YES WB 0.07 BCDL 5.0 Code FBC2010/TPI2007 (Matrix) LUMBER - TOP CHORD 2x4 SP No.2(flat) BOT CHORD 2x4 SP No.2(flat) WEBS 2x4 SP No.3(flat) BRACING - TOP CHORD Structural wood sheathing directly applied or 3-3-15 cc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 cc bracing. REACTIONS. (lb/size) 4 = 157/Mechanical 1 = 157/0-3-0 (min. 0-1-8) Max Grav 4 = 157(LC 1) 1 = 157(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES; 1) Plates checked for a plus or minus 0 degree rotation about its center. 2) Refer to girder(s) for truss to truss connections. 3) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 cc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 6) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard DEFL. in (loc) Iidefl L/d PLATES GRIP Vert(LL) -0.00 5 >999 480 MT20 244/190 Vert(TL) -0.00 5 > 999 360 Horz(TL) . 0.00 4 n/a n/a Weight: 26 lb FT = 0%F, 0%E Julius Lee, P.E. #34869— 1109 Coastal Bay — Boynton Beach, FL 33435 Job Truss Truss Type , r Qty Ply A0134369 59941 FL33 Floor 1 1 Job Reference (optional) Al ROOF TRUSSES, FORT PIERCE, FL 34946 7.600 s Oct 3 2014 MiTek Industries, Inc. Fri Nov 07 09:12:28 2014 Page 1 I D: M8gd Rulfexy Woi5_CtkLoayLvGV-Msle7JMrZ6 E_5b821XVleg U4Y4Q FHY?XPegEGlyLds 0-3-8 3x6 II 3x6 II 1-6-1 1.5x4 II 3x6 = ,0-3-8, 2-2-1 0-3-8 1-10-9 Plate Offsets (X Y)--(4:Edge 0-0-121 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.07 Vert(LL) 0.00, 4 ' " 480 MT20 244/190 TCDL 10.0 Lumber DOL 1.00 BC 0.02 Vert(fL) -0.00 3-4 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 n/a n/a BCDL 5.0 Code FBC2010frPI2007 (Matrix) Weight: 17 lb FT = O%F, 0%E LUMBER - TOP CHORD 2x4 SIP No.2(flat) BOT CHORD 2x4 SP No.2(flat) WEBS 2x4 SIP No.3(flat) BRACING - TOP CHORD Structural wood sheathing directly applied or 2-2-1 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 3 = 93/Mechanical 1 = 93/0-3-0 (min. 0-1-8) Max Grav 3 = 93(LC 1) 1 = 93(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Plates checked for a plus or minus 0 degree rotation about its center. 2) Refer to girder(s) for truss to truss connections. 3) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 6) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard Julius Lee, P_E_ #34869— 1109 Coastal Bay— Boynton Beach, FL 33435 Job Truss Truss Type Qty Ply A0134370 59941 FL34 Floor 1 1 �J.b Reference (optional) Al KUUt- I KU6bt6, rUK I VItKUt, rL C4U413 LOADING(psf) SPACING- 2-0-0 CSI. TCLL 40.0 Plate Grip DOL 1.00 TC 0.02 TCDL 10.0 Lumber DOL 1.00 BC 0.00 BCLL 0.0 Rep Stress Incr YES WB 0.00 BCDL 5.0 Code FBC2010/TP12007 (Matrix) LUMBER - TOP CHORD 2x4 SP No.2(flat) BOT CHORD 2x4 SP No.2(flat) WEBS 2x4 SP No.3(flat) BRACING - TOP CHORD Structural wood sheathing directly applied or 1-0-4 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 4 = 48/Mechanical 1 = 46/0-3-0 (min. 0-1-8) Max Grav 4 = 48(LC 1) 1 = 46(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Plates checked for a plus or minus 0 degree rotation about its center. 2) Refer to girder(s) for truss to truss connections. 3) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard 7.60 s Oct 3 2014 MiTek Industries, Inc. Fri Nov 07 09:12:28 2014 Page 1 ryW i5_CtkLoayLvGV-Msje7JMrZ6E_5b821XVIegU5L4QaHY2XPegEGlyLds IL on 5 4 1.5x4 II 46 = DEFL. in (loc) I deft Ud Vert(LL) -0.00 5 999 480 Vert(TL) -0.00 5 999 380 Horz(TL) 0.00 4 n/a n/a PLATES GRIP MT20 244/190 Weight: 11 lb FT--' 0%F, 0%E Julius Lee, P.E. #34869 — "09 Coastal Bay — Boynton Beach, FL 33435 Job Truss Truss Type Qty Ply 59941 FL35 Floor 1 1 A0134371 Job Reference o tional Al KUUr I KUtAbtb, rUK I L'I Kt t:, hL J4U40 13x3 II 3x4 = 2 7.600 s Oct 3 2014 MiTek Industries, Inc. Fri Nov 07 09:12:29 2014 Page 1 ID:M8gdRulfexyWoi5_CtkLoayLvGV-g3HOKfM U KQMO]jEJFOXBtl7eUgDOvdhdlQnpkyLdsrr i 4 3x3 = 46 11 5 3x6 = 3x4 = 9 8 7 6 1.5x4 11 1.5x4 11 7412 7-6-12 7-2-12 0-4-0 Plate Offsets (X,Y)--[2:0-1-8,Edgel, [5:0-3-0,Edgel, [7:0-1-8,Edgel LOADING(psf) SPACING- 2-0-0 CSL DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.62 Vert(LL) -0.05 8-9 >999 480 MT20 244/190 TCDL 25.0 Lumber DOL 1.00 BC 0.42 Vert(TL) -0.08 8-9 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.43 Horz(TL) 0.01 5 n/a n/a BCDL 5.0 Code FBC201 O/TPI2007 (Matrix) Weight: 39 lb FT = 0%F, 0%E LUMBER - TOP CHORD 2x4 SP No.2(flat) BOT CHORD 2x4 SP No.2(flat) WEBS 2x4 SP No.3(flat) BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 9 = 493/Mechanical 5 = 493/0-3-8 (min. 0-1-8) Max Gray 9 = 493(LC 1) 5 = 493(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-843/0, 3-4=-843/0, 4-5=-849/0 BOT CHORD 8-9=0/843, 7-8=0/843 WEBS 2-9=-904/0, 5-7=0/900, 3-7=278/0 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) Refer to girder(s) for truss to truss connections. 4) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 5) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-1 Od (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 7) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard Julius Lee, P.E. #34869— 1109 Coastal Bay— Boynton Beach, FL 33435 Job Job Truss Tru Truss Type � t Qty Ply 1 A0134372 Fuss Floor 1 1 ob Reference o tional Al KUUt• I KUbbtb, t-UK 11'ItKL:t, t•L 44U40 1 3x3 II 3x6 = 9 7.60P s Oct 3 2014 MiTek Industries, Inc. Fri Nov 07 09:12:29 2014 Page 1 ID.M8gdRulfexy oi5_CtkLoaylvGV-g3HOKfMUKQMd[jEJFOXBt18TUiA0wAhdlQnpkyLdsn 0-5-6 0F=4� 3x4 = 1.5x4 11 I 3x3 = 4x6 11 2 3 4 5 1.5x4 II 3x4 = 8 7 1.5x4 II 6 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I�defl Ud PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.57 Vert(LL) -0.02 8-9 >999 480 MT20 244/190 TCDL 25.0 Lumber DOL 1.00 BC 0.30 Vert(TL) -0.04 8-9 999 360 BCLL 0.0 Rep Stress Incr YES , WB 0.33 Horz(TL) 0.00 5 n/a n/a BCDL 5.0 Code FBC201 O/TPI2007 (Matrix) Weight: 35 lb FT = 0%F, 0%E LUMBER - TOP CHORD 2x4 SP No.2(flat) BOT CHORD 2x4 SP No.2(flat) WEBS 2x4 SP No.3(flat) BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pur ins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 9 = 412/Mechanical 5 = 412/0-3-8 (min. 0-1-8) Max Gray 9 = 412(LC 1) 5 = 412(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-649/0, 3-4=-649/0, 4-5=-655/0 SOT CHORD 8-9=0/649, 7-8=0/649 WEBS 5-7=0/693, 2-9=-696/0 NOTES- 1) Unbalanced floor live loads have been considered for this design. 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) Refer to girder(s) for truss to truss connections. 4) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 5) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-1 Od (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 6) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 7) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard Julius Lee, P.E_ #34869-11109 Coastal Bay — Boynton Beach, FL 33435 Job Truss Truss Type I r Qty Ply 59941 FL37 Floor 1 1 A0134373 o tional Job Reference Al ROOF TRUSSES, FORT PIERCE, FL 34946 . 7.600 s Oct 3 2014 MiTek Industries, Inc. Fri Nov 07 09:12:29 2014 Page 1 I D: M8 qd Rulfexy Woi5_CtkLoayLvGV-g3HOKfM U KQMdlj EJFOXBtl 8M U kEGyandl Qn pkyLdsn 2-6-0 1-11-1 1 3x3 11 3x4 = 3x3 = 4x6 11 2 3 4 3x6 = 3x4 = 1.5x4 11 7 6 5 LOADING(psf) SPACING- 2-0-0. CSI. DEFL. in (loc) I/defi Ud PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.51 Vert(LL) -0.01 6 >999 480 MT20 244/190 TCDL 25.0 Lumber DOL 1.00 BC 0.17 Vert(TL) -0.01 6-7 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.24 Horz(TL) -0.00 4 n/a n/a BCDL 5.0 Code FBC201 O/TPI2007 (Matrix) Weight: 30 lb FT = 0%F, 0%E LUMBER - TOP CHORD 2x4 SP No.2(flat) BOT CHORD 2x4 SP No.2(flat) WEBS 2x4 SP No.3(flat) BRACING - TOP CHORD Structural woad sheathing directly applied or 5-3-1 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 7 = 331/Mechanical 4 = 331/0-3-8 (min. 0-1-8) Max Grav 7 = 331(LC 1) 4 = 331(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-454/0, 3-4=-458/0 BOT CHORD 6-7=0/454 WEBS 4-6=0/503, 2-7=-487/0 NOTES- 1) Plates checked for a plus or minus 0 degree rotation about its center. 2) Refer to girder(s) for truss to truss connections. 3) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-1 Od (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 6) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard Julius Lee, P-E_ #34869— 1109 Coastal Bay — Boynton Beach, FL 33435 Job Truss Truss Type Qty Ply A0134374 59941 FL38 FLOOR 1 1 ob Reference (optional) Al KUUF I KUbbtb", rUK I VItKUL, r-L 44`J40 i 1-7-9 43 — 1 3x3 II 2 3x6 = 7 i LOADING(psf) SPACING- 2-0-0 CSI. TCLL 40.0 Plate Grip DOL 1.00 TC 0.22 TCDL 25.0 Lumber DOL 1.00 BC 0.09 BCLL 0.0 Rep Stress Incr YES WB 0.14 BCDL 5.0 Code FBC2010/TP12007 (Matrix) LUMBER- TOP CHORD 2x4 SP No.2(flat) BOT CHORD 2x4 SP No.2(flat) WEBS 2x4 SP No.3(flat) BRACING - TOP CHORD Structural wood sheathing directly applied or 4-1-3 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 7 = 250/Mechanical 4 = 250/0-3-8 (min.0-1-8) Max Gray 7 = 250(LC 1) 4 = 250(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-257/0, 3-4=-260/0 BOT CHORD 6-7=0/257 WEBS 4-6=0/294, 2-7=-296/0 NOTES- 1) Plates checked for a plus or minus 0 degree rotation about its center. 2) Refer to girder(s) for truss to truss connections. 3) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 4) Recommend 2x6 strongbacks, on edge, spaced at 10-0-0 oc and fastened to each truss with 3-10d (0.131" X 3") nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 5) Gap between inside of top chord bearing and first diagonal or vertical web shall not exceed 0.500in. 6) CAUTION, Do not erect truss backwards. LOAD CASE(S) Standard 6 3x3 = 7.60 s Oct 3 2014 MiTek Industries, Inc. Fri Nov 07 09:12:30 2014 Page 1 3x3 = 3x6 1 0.4.0 3 4 1.5x4 If 5 3-9-3 1 , 4-1-3 4 9 N DEFL. in (loc) Ildefl L/d PLATES GRIP Vert(LL) -0.00 6 999 480 MT20 244/190 Vert(TL) -0.00 6 999 360 Horz(TL) 0.00 4 n/a n/a Weight: 25 lb FT = 0%F, 0%E Julius Lee, P.E. ;;34869-1: Coastal Bay —Boynton Beach, FL 3343S Job Truss Truss Type r Qty Ply A0134375 59941 HJA Diagonal Hip Girder 1 1 �J.bR.ference (optional) Al ROOF TRUSSES, FORT PIERCE, FL 34946 7.600 s Oct 3 2014 MiTek Industries, Inc. Fri Nov 07 09:12:31 2014 Page 1 ID:nTgtNvPNwyOwNLlv4xWHRyyMD8g-nRPnILOks1 cZy3tdQf3?Gl6VnINcUvp_ScvutdyLdsl 0- -0 2-0-12 2-6-14 6-5-13 0- -2 2-0-12 0-6-2 3-10-15 3x4 = 2 1 3x4 = 3x4 = 1-2-14 2-6-14 2.00 12 fit 0.50 F,2 Plate Offsets(X,Y)--f2:0-10-1,0-0-61.f2:0-3-O,Edgel LOADING(psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.45 Vert(LL) 0.07 5 >999 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.36 Vert(TL) -0.11 5 >679 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) 0.02 3 n/a n/a BCDL . 10.0 Code FBC201 OfrPI2007 (Matrix-M) Weight: 20 lb FT = 0% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (Ib/size) 3 = 181/Mechanical 2 = 423/1-4-0 (min. 0-1-8) 4 = 31/Mechanical Max Horz 2 = 68(LC 8) Max Uplift 3 = -111(LC 8) 2 = -162(LC 8) Max Grav 3 = 181(LC 1) 2 = 423(LC 1) 4 = 62(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-9 504/541 BOT CHORD 2-10=-524/492 NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=S.Opsf; h=28ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus.0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections.. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 3=111, 2=162. 7) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 151 lb down and 122 lb up at 4-3-0 on top chord, and 34 lb up at 4-3-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-2=-30, 2-3=-90, 5-6=-20, 4-5=-20 Concentrated Loads (lb) Vert: 11=60(B) 12=17(B) Jutius.Lee, P.E. #34869— 1109 Coastal Bay— Boynton Beach, FL 33435 Job Truss Truss Type f t Oty Fly AO134376 59941 HJAA Diagonal Hip Girder 1 1 ob Reference o tional Al ROOF TRUSSES, F ov 07 09:12:31 2014 Page 1 3? G 16VtI O N Uvp_5cvutdyLdsl Plate Offsets X Y -- 2:0-10-1 0-0-6 2:0-3-0 Edgel LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) /deft Ud PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.45 Vert(LL) 0.06 5 999 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.31 Vert(TL) -0.10 _ 5 732 240 BCLL 0.0 * Rep Stress Incr YES WB 0.00 Horz(TL) 0.02 3 n/a n/a BCDL 10.0 Code FBC2010frPI2007 (Matrix-M) Weight: 18 lb FT = 0% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING - TOP CHORD Structural woad sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation uide. REACTIONS. (lb/size) 3 = 186/Mechanical 2 = 415/1-4-0 (min. 0-1-8) 4 = 27/Mechanical Max Horz 2 = 63(LC 29) Max Uplift 3 = -109(LC 8) 2 = -159(LC 8) Max Grav 3 = 186(LC 1) 2 = 415(LC 1) 4 = 54(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-9=-373/385 BOT CHORD 2-10=-372/364 NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=28ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C. Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of trus to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 3=109, 2=159. 7) "Semi -rigid pitchbreaks with fixed heels" Member and fixity model was used in the analysis and design oft iis truss. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1 771 down and 140 lb up at 3-9-2 on top chord, and 39 I up at 3-9-2 on bottom chord. The design/selection of uch connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied tot e face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Ins Plate Increase=1.25 Uniform Loads (plf) Vert: 1-2=-30, 2-3=-90, 5-6=-20, 4-5=-20 Concentrated Loads (lb) Vert: 11=10(B) 12=19(B) Julius Lee, P.E. #34869-11109 Coastal Bay — Boynton Beach, FL 33435 Job Truss Truss Type y Qty Ply 59941 JA Jack -Open 1 1 A0134377 Job Reference optional Al ROOF TRUSSES, FORT PIERCE, FL 34946 7.600 s Oct 3 2014 MiTek Industries, Inc. Fri Nov 07 09:12:32 2014 Page 1 ID:nTgtNvPNwyOwNLlv4xWHRyyMD8g-Fez9zh PMdLkOZDSp_NaEp Wee WhelDM37JGeSP3yLdz 0- -0 1-6 8 7-11-3 0- -1 1_ _8 6-4-11 Dead Load Defl. = 1/8 in Io N N I� 0.87 12 0-9-7 , 1-6-8 , 7-11-3 1 0-9-7� 0- 6-4-11 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.58 Vert(LL) -0.02 6 >538 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.69 Vert(TL) -0.24 4-5 >315 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) -0.01 3 n/a n/a BCDL 10.0 Code FBC201 O/TPI2007 (Matrix-M) Weight: 24 lb FT = 0% LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 0-8-13 except Qt=length) 3=Mechanical, 4=Mechanical. (lb) - Max Harz 2= 144(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 2 except 3=-163(LC 12), 5=-264(LC 8) Max Grav All reactions 250 lb or less at joint(s) 3, 2, 4, 2 except 5=463(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-501 /560 BOT CHORD 2-9=-682/603 NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) . Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=28ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS. (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber,DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 2 except at --lb) 3=163, 5=264. 7) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Julius Lee, P.E. #34869 — 1109 Coastal Bay — Boynton Beach, FL 33435 Job Truss Truss Type r Qty Ply AO134378 59941 JAA Jack -Open 1 1 Lb Reference (optional) At ROOF I RUSbEb, FUR I NILHUt, FL MUft 0-0-1 1-6-8 3.46 12 T 2 � 6• 3x8 = G 3x4 = 5 9 M- ill B2 0.87 rl 2 s Oct 3 2014 MiTek Industries, Inc. Fri Nov 07 09:12:32 2014 Page 1 WHRyyMDBg-Fezgzh PMdLkQZDSp_NaEp WefDhfXDM37JGeSP3yLde LOADING(psfl SPACING- 2-0-0 CSI. DEFL. in (loc) deft Ud TCLL 30.0 Plate Grip DOL 1.25 TC 0.54 Vert(LL) -0.02 6 583 360 TCDL 15.0 Lumber DOL 1.25 BC. 0.64 Vert(fL) -0.20 4-5 360 240 BC LL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) -0.01 3 n/a n/a BC DL 10.0 Code FBC2010/TP12007 (Matrix-M) 1 LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in . accordance with Stabilizer Installation quide. REACTIONS. All bearings 0-8-13 except dt=length) 3=Mechanical, 4=Mechanical. (lb) - Max Horz 2= 139(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 2 except 3=-156(LC 12), 5=-242(LC 8) Max Grav All reactions 250 lb or less at joint(s) 3, 2, 4, 2 except 5=426(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-459/514 BOT CHORD 2-9=-627/552 NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=28ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 2 except at --lb) 3=156, 5=242. 7) "Semi -rigid pitchbreaks with fixed heels" Member fixity model was used in the analysis and design of t truss. LOAD CASE(S) Standard 3 Dead Load Defl. = 118 in N N W N N I� PLATES GRIP MT20 244/190 Weight: 23 lb FT = 0% Julius Lee, P.E. #34569 —1 1109 Coastal Bay — Boynton Beach, FL 33435 Jab Truss Truss Type Qty Ply A0134379 59941 JB Jack -Open 1 1 Job Reference (optional) Al ROOF TRUSSES, FORT PIERCE, FL 34946 7.600 s Oct 3 2014 MiTek Industries, Inc. Fri Nov 07 09:12:33 2014 Page 1 ID:nTgtNvPNwyOwNLlv4xWHRyyMD8g-jgWXA1 Q_OesHBM 1 ?Y45TLjBmJ51 xypJHYwO?yWyLd., O- -0 1-6-8 6-9-5 0- 1 1-6-8 5-2-13 I$ lead Load Del. =1116 in d I$ 0.87 12 5 3x4 = i 0-9-7 , � 0-9-7 0-9-0 5-2-13 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.77 Vert(LL) -0.01 6 >745 360 MT20 244/190 TCDL 15.0 Lumber DO 1.25 BC 0.50 Vert(TL) -0.11 4-5 >577 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.01 3 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight: 21 lb FT = 0% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation quide. REACTIONS. All bearings 0-8-13 except at --length) 3=Mechanical, 4=Mechanical. (lb) - Max Horz 2= 123(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 2 except 3=-136(LC 12). 5=-185(LC 8) Max Grav All reactions 250 lb or less at joint(s) 3, 2, 4, 2 except 5=328(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-295/331 BOT CHORD 2-9=-455/396 NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=S.Opsf; h=28ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) . This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by.others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 2 except Qt=lb) 3=136, 5=185. 7) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Julius Lee, P-E. ##34869— 1109 Coastal Bay — Boynton Beach, FL 33485 Job Truss Truss Type i r Qty Ply AO134380 59941 JBA Jack -Open 1 1 Job Reference (optional) Al KUUt- I KUbbtb, hUK I YItKI:t, rL J4H41a 7.600 s Oct 3 2014 MiTek Industries, Inc. Fri Nov 07 09:12:33 2014 Page 1 Llv xWHRyyMD8g-jgWXA1Q_OesHBM1?Y45TLjBoQ51gypJHYwO?yWyLd; 3 3.46 12 N d T1 .r o B2 4 I$ 5 0.87 12 3x4 = LOADING(psf) SPACING- 2-0-0 CSL DEFL. in (loc) I/defl L/d TCLL 30.0 Plate Grip DOL 1.25 TC 0.70 Vert(LL) -0.01 6 >822 360 TCDL 15:0 Lumber DOL 1.25 BC 0.45 Vert(TL) -0.09 4-5 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 3 1>680 n/a n/a BCDL 10.0 Code FBC2010/rP12007 (Matrix-M) LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 cc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 cc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with,Stabilizer Installation ouide. REACTIONS. All bearings 0-8-13 except Qt=length) 3=Mechanical, 4=Mechanical. (lb) - Max Horz 2= 118(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 2 except 3=-130(LC 12), 5=-167(LC 8) Max Grav All reactions 250 lb or less at joint(s) 3, 2, 4, 2 except 5=296(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-263/296 BOT CHORD 2-9=-408/354 NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=28ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. ' 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of tru bearing plate capable of withstanding 100 lb uplift joint(s) 2, 2 except (jt=lb) 3=130, 5=167. 7) "Semi -rigid pitchbreaks with fixed heels" Membe fixity model was used in the analysis and design of truss. LOAD CASE(S) Standard to PLATES GRIP MT20 244/190 Weight: 20 lb FT = 0% Julius Lee, P.E. #34869 4 1109 Coastal Bay — Boynton Beach, FL 33435 Job ss Truss Type ! Qty Ply 59941 P Jack -Open 1 1 A0134381 Job Reference (optional) Al ROOF TRUSSES, FORT PIERCE, FL 34946 7.600 s Oct 3 2014 MiTek Industries, Inc. Fri Nov 07 09:12:34 2014 Page 1 I D:nTgtNvPNwyOwNLlv4xWHRyyMD8g-B04vNNQc9y_8p WcC6ociuxkOJVP3hGZQna7YUyyLds 0-p-0 1-6-8 5-7-7 0-b 1 1-6 8 4-1-0 3x4 = 53x4 = 0.87 12 0-9-7 , 0-9-7 1-6-8 0-9-0 5-7-7 4-1-0 Plate Offsets (X,Y)-- [2:0-4-9, 0-0-111 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (Jac) Well Ud PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.50 Vert(LL) -0.02 4-5 >999 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.32 Vert(TL) -0.04 4-5 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 3 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) Weight: 17 lb FT = O% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 5-7-7 cc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 0-8-13 except (jt=length) 3=Mechanical, 4=Mechanical. (lb) - Max Harz 2= 102(LC 8) Max Uplift All uplift 100 lb or less at joint(s) except 3=-11 O(LC 12), 2=-103(LC 8), 5=-115(LC 8) Max Grav All reactions 250 lb or less at joint(s) 3, 2, 5, 4, 2 FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. BOT CHORD 2-9=-270/235 NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=28ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 110 lb uplift at joint 3, 103 lb uplift at joint 2, 115 lb uplift at joint 5 and 103 lb uplift at joint 2. 7) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S) Standard Julius Lee, P_E_ #34869— 1109 Coastal Bay —Boynton Beach, FL 33435 Job Truss Truss Type Qty Ply A0134382 59941 JCA Jack -Open 1 1 ob Reference o tional At ROOF TRUSSES, FORT PIERCE, FL 34946 s Oct 3 2014 MiTek Industries, Inc. Fri Nov 07 09:12:34 2014 Page 1 xWHRyyMD8g-B04vNNQcgy_8pWcC6ocluxkI CVPihGZQna7YUyyLdsl 0- -0 1-8 5-4- 0- -1 1-6-6 8 3-9- 3.46 F12 T1 2 1 B2 3x4 = 3x4 = 0.87 12 5 1-6-8 6-4-2 0-9-0 3-9-10 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) 1/defl L/d TCLL 30.0 Plate Grip DOL 1.25 TC 0.44 Vert(LL) -0.01 4-5 >999 360 TCDL 15.0 Lumber DOL 1.25 BC 0.27 Vert(TL) -0.03 4-5 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 3 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 5-4-2 cc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 cc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation ouide. REACTIONS. All bearings 0-8-13 except at --length) 3=Mechanical, 4=Mechanical. (lb) - Max Horz 2= 97(LC 8) Max Uplift All uplift 100 lb or less at joint(s) except 3=-104(LC 12), 2=-11 O(LC 8), 5=-100(LC 8) Max Grav All reactions 250 lb or less at joint(s) 3, 2, 5, 4, 2 FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; 8CDL=5.0psf h=28ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 104 lb uplift at joint 3, 110 lb uplift at joint 2, 100 lb uplift at joint 5 and 110 lb uplift at joint 2. 7) "Semi -rigid pitchbreaks with fixed heels" Mem fixity model was used in the analysis and design truss. LOAD CASE(S) Standard end W Id PLATES GRIP MT20 244/190 Weight: 16 lb FT = 0% Julius Lee, P.E_ #34869 f- 1109 Coastal Bay — Boynton Beach, FL 33435 Job Truss .Truss Type Qty Ply A0134383 59941 JD Jack -Open 1 1 Job Reference o tional Al ROOF TRUSSES, FORT PIERCE, FL 34946 7.600 s Oct 3 2014 MiTek Industries, Inc. Fri Nov 07 09:12:34 2014 Page 1 I D:n TgtNvP NwyOwN Llv4xW H RyyM D8 g-BO4vN N Qc9y_8p WcC6o ciuxk3ljVRXh GZQna7YUyy Ldsl 0- -0 1-6-8 4-5-9 0 -1 1-6 8 2-11-2 5 3x4'= 0-9-7 118 4-5-9 n�T 5-9-0 2-11-2 Plate Offsets (X,Y)--f2:0-4-9 0-0-31 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.28 Vert(LL) -0.00 4-5 >999 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.16 Vert(TL) -0.01 4-5 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 3 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight: 14 lb FT = 0% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- LOAD CASE(S) TOP CHORD Standard Structural wood sheathing directly applied or 4-5-9 cc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 cc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation quide. REACTIONS. All bearings 0-8-13 except at --length) 3=Mechanical, 4=Mechanical. (lb) - Max Horz 2= 81(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 3, 5 except 2=-126(LC 8) Max Grav All reactions 250 lb or less at joint(s) 3, 2, 5, 4, 2 FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=28ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 5 except at --lb) 2=126, 2=126. 7) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. Julius Lee. P.E. 934869 — 1109 Coastal Bay — Boynton Beach, FL 3343S Job Truss Truss Type + 1 Qty Ply AO134384 59941 JDA Jack -Open 1 1 ob Reference (optional) Al KUUh I KUbb"tb, 1-UK I NItKUt, 1-1- J4U4b 1-6-8 3.46 12 T1 2 1 B2 B 2x4 = 0.87 12 5 3x4 = ,0-9-7 1-6-8,4-2-4 5 Vc[ J Lu 14 IVII I ex muu5me5, inc. rn rvov ui uw. ix.Jo zu 14 3 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d TCLL 30.0 Plate Grip DOL 1.25 TC 0.24 Vert(LL) -0.00 4-5 >999 360 TCDL 15.0 Lumber DOL 1.25 BC 0.12 Vert(TL) -0.01 4-5 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(fL) -0.00 3 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- LOAD CASE(S) TOP CHORD Standard Structural wood sheathing directly applied or 4-2-4 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 0-8-13 except at --length) 3=Mechanical, 4=Mechanical. (lb) - Max Horz 2= 76(LC 12) Max Uplift All uplift 100 lb or less at joint(s) 3, 5 except 2=-129(LC 8) Max Grav All reactions 250 lb or less at joint(s) 3, 2, 5, 4, 2 FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=28ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall . by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 5 except Qt=lb) 2=129, 2=129. 7) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. E PLATES GRIP MT20 244/190 Weight: 13 lb FT = 0% Julius Lee, P.E. #34869 {- 1109 Coastal Bay — Boynton Beach, FL 33435 Job Truss Truss Type I } Qty Ply 59941 JE Jack -Open 1 1 A0134385 Job Reference (optional) Al ROOF TRUSSES, FORT PIERCE, FL 34946 7.600 s Oct 3 2014 MiTek Industries, Inc. Fri Nov 07 09:12:35 2014 Page 1 I D:nTgtNvP NwyOwN LIv4x WH RyyM D8g-fD elbiREwF6?RgAOfV7xQ8GHtvpaQjoZO Et60OyLd sc 0-Q-0 3-3-12 0- -1 1-6-8 1-9-4 3x4 = 5 0-9-7 0-9-0 1-9-4 ji Plate Offsets (X,Y)--f2:0-0-15,0-6-71, (2:0-0-8,Edgel LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.13 Vert(LL) 0.00 6 >999 360 MT20 244/190 TCDL 15.0 Lumber DOL . 1.25 BC 0.04 Vert(TL) -0.00 4-5 >999. 240 BCLL 0.0 ` Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 3 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) Weight: 10 lb FT = 0% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- LOAD CASE(S) TOP CHORD Standard Structural wood sheathing directly applied or 3-3-12 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation quide. REACTIONS. All bearings 0-8-13 except (jt=length) 3=Mechanical, 4=Mechanical. (lb) - Max Horz 2= 60(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 3, 5 except 2=-133(LC 8) Max Grav All reactions 250 lb or less at joint(s) 3, 2, 5, 4, 2 FORCES. (lb) Max. Comp./Max. Ten. All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=28ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 5 except at=lb) 2=133, 2=133. 7) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. Julius Lee, P-E. #34869— 1109 Coastal Bay— Boynton Beach, FL 33435 Job Truss Truss Type i 4 Qty Ply A0134386 59941 JEA Jack -Open 1 1 ob Reference o tional Al ROOF TRUSSES, FORT PIERCE, FL 34946 1-6-8 2x4 = 2x4 II d 3.46 12 T1 B2 0 0.67 F12 5 3x4 = •8 1 3-0-6 s Oct 3 2014 MiTek Industries, Inc. Fri Nov 07 09:12:36 2014 Page 1 .lv4xW H RyyM D8g-7PCgo2 SthZF s2glaDDeAzLpS2J 919A2jE u ctYgyLds LOADING(psf) SPACING- 2-0-0 CS'. DEFL. in (loc) 1/defl Ud TCLL 30.0 Plate Grip DOL 1.25 TC 0.10 Vert(LL) 0.00 6 >999 360 TCDL 15.0 Lumber DOL 1.25 BC 0.03 Vert(TL) -0.00 5 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 3 n/a n/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- LOAD CASE(S) TOP CHORD Standard Structural wood sheathing directly applied or 3-0-6 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 0-8-13 except at --length) 3=Mechanical, 4=Mechanical. (lb) - Max Horz 2= 54(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 3, 5 except 2=-132(LC 8) Max Gray All reactions 250 Ib or less at joint(s) 3, 2, 5, 4, 2 FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=S.Opsf; BCDL=5.Opsf; h=28ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 5 except Qt=1b) 2=132, 2=132. 7) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. PLATES GRIP MT20 244/190 Weight: 9 lb FT = 0% Julius Lee, P.E. #34569 }- 1109 Coastal Bay — Boynton Beach, FL 33435 Job Truss Truss Type Oty Ply 59941 JF Jack -Open 1 1 A0134387 ' Job Reference optional Al ROOF TRUSSES, FORT PIERCE, FL 34946 7.600 s Oct 3 2014 MiTek Industries, Inc. Fri Nov 07 09:12:36 2014 Page 1 I D:nTgtNvPNwyOwNLlv4xWH RyyMD8g-7PCgo2SthZFs2glaDDeAzLpTvJ9y9A2jEucfYgyLds 0.Q-0 1-6-8 2-1-'f4 0- -1 1-6-8 0-7-6 1-6-4 1-6-4 5 3x4 = 1- -8 0- -3 2-1-14 0-7-6 Plate Offsets (X,Y)--[2:0-0-15,0-6-71, [2:0-0-8,Edgel LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.05 Vert(LL) -0.00 6 >999 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.03 Vert(TL) -0.00 6 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 3 n/a n/a BCDL 10.0 Code FBC201 O/TPI2007 (Matrix-M) Weight: 7 lb FT = 0% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- LOAD CASE(S) TOP CHORD Standard Structural wood sheathing directly applied or 2-1-14 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 cc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation quide. REACTIONS. All bearings 0-8-13 except (jt=length) 3=Mechanical, 4=Mechanical. (lb) - Max Horz 2= 38(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 3, 5 except 2=-125(LC 8) Max Grav All reactions 250 lb or less at joint(s) 3, 2, 5, 4, 2 FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=6.Opsf; h=28ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 5 except Qt=lb) 2=125, 2=125. 7) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. Julius Lee, P.E. #34869 — 1109 Coastal Bay — Boynton Beach, FL 33435 Job Truss Truss Type e I Qty Ply A0134388 59941 JFA Jack -Open 1 1 ob Reference (optional) Al ROOF TRUSSES, FORT FIERCE, FL 34946 "3 u 5 uct a Lu l4 IVII 1 eK hmubbiub, mu. r11 IVUV ut uu' IG:a/ N I9 r ID:nTgtNvPNwyOwN LIv4xWHRyyMD8g-bbm200TVStNjg_KnnwAPWZMdFiVuudisTYMD5h 0- -0 1-10-9 0 1 1-10-9 3.46 12 3 21 T1 N d 4 oJW 0 1 2 E___ IC� = CD2x4 2x4 11 0.871 5 3x4 = 1-6-4 1--81-10- 1-6-4 0--30-4-1 Plate Offsets X Y -- 2:0-0-15 0-6-8 2:0-0-8 Ed e LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (too) Udefl Ud PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.07 Vert(LL) -0.00 6 >999 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.05 Vert(TL) -0.00 6 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 3 n/a n/a BCDL 10.0 Code FBC201 O/TP12007 (Matrix-M) Weight: 6 lb FT = 0% LUMBER - TOP CHORD 2x4 SP No.2 7) "Semi -rigid pitchbreaks with fixed heels" Member end BOT CHORD 2x4 SP No.2 fixity model was used in the analysis and design of I iis BRACING- truss. TOP CHORD Structural wood sheathing directly applied or 1-10-9 oc purlins. LOAD CASE(S) BOT CHORD Standard Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 192/0-8-13 (min. 0-1-8) 4 = 3/Mechanical 3 = 16/Mechanical Max Horz 2 = 34(LC 8) Max Uplift 2 =-136(LC 8) 3 = -20(LC 12) Max Grav 2 = 192(LC 1) 4 = 7(LC 3) 3 = 16(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=28ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus -or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3 except (jt=lb) 2=136. Julius Lee, P.E. #34869 1109 Coastal Bay — Boynton Beach, FL 33435 8 Job Truss Truss Type Ply 59941 JG Jack -Open �Qty 1 1 A0134389 Job Reference (optional) Al ROOF TRUSSES, FORT PIERCE, FL 34946 21 1-6-8 5 3x4 = 0-9-7 1-6-8 3-8-13 0-9-7 0-9-0 2-2-5 7.600 s Oct 3 2014 MiTek Industries, Inc. Fri Nov 07 09:12:37 2014 Plate Offsets (X,Y)-- [2:0-0-15,0-6-81, [2:0-0-8,Edgel LOADING(psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.18 Vert(LL) -0.00 4-5 >999 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.08 Vert(TL) -0.00 4-5 >999 240 BCLL 0.0 * Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 3 n/a n/a BCDL 10.0 Code FBC201 O/TPI2007 (Matrix-M) Weight: 11 lb FT = 0% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- LOAD CASE(S) TOP CHORD Standard Structural wood sheathing directly applied or 3-8-13 cc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation ouide. REACTIONS. All bearings 0-8-13 except at --length) 3=Mechanical, 4=Mechanical. (lb) - Max Horz 2= 67(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 3, 5 except 2=-1 32(LC 8) Max Grav All reactions 250 lb or less at joint(s) 3, 2, 5, 4, 2 FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=28ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1:60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) : This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-5-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 5 except Qt=lb) 2=132, 2=132. 7) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. Julius Lee, P_E_ #34869— 1109 Coastal Bay— Boynton Beach, FL 33435 Job Truss Truss Type Qty Ply 59941 JGA Jack -Open 1 1 AO134390 ob Reference (optional) Al HOOF I KUbStb, FOIL I PILRUL, FL 3484ti 1-10-14 7.6 0 s Oct 3 2014 MiTek Industries, Inc. Fri Nov 07 09:12:38 2014 Page 1 3.46 F12 3 V N T1 21 4 B B2 � to Ia 2x4 = 2x4 0 0.67 F12 5 3x4 = 0-9-7 1-6-8 3-5-5 0-9-7 1 0-9-0 1-10-14 Plate Offsets X -- 2:0-0-15 0-6-8 2:0-0-8 Edgel LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.14 Vert(LL) 0.00 6 >999 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.05 Vert(TL) -0.00 4-5 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 3 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight: 11 lb FT = 0% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- LOAD CASE(S) TOP CHORD Standard Structural wood sheathing directly applied or 3-5-5 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation quide. REACTIONS. All bearings 0-8-13 except Qt=length) 3=Mechanical, 4=Mechanical. (lb) - Max Horz 2= 62(LC 12) Max Uplift All uplift 100 lb or less at joint(s) 3, 5 except 2=-1 33(LC 8) Max Grav All reactions 250 lb or less at joint(s) 3, 2, 5, 4, 2 FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=28ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 5 except Qt=lb) 2=133, 2=133. 7) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. Julius Lee, P.E. #34869 — 1109 Coastal Bay — Boynton Beach, FL 33435 Job Truss Truss Type Qty Ply 59941 JH Jack -Open 1 1 A0134391 Job Reference o tional Al ROOF TRUSSES, FORT PIERCE, FL 34946 7.600 s Oct 3 2014 MiTek Industries, Inc. Fri Nov 07 09:12;38 2014 Page 1 I D:nTgtNvPNwyOwNLIv4xWH RyyMD8g4nKQDkT7DAVal8vzLdhe2muo46rVd4YOiC5mdjyLds( 0-Q-0 1-6-8 2-6-15 0- -1 1-6-8 1-0-7 5 3x4 = 0-9-7 1-6-8 2-6-15 0-9-7 0-9-0 1-0-7 Plate Offsets (X,Y)--[2:0-0-15,0-6-81, [2:0-0-8,Edgel LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (Icc) I/deft Ud PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.07 Vert(LL) 0.00 6 >999 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.03 Vert(TL) -0.00 6 >999 240 BCLL 0.0 ` Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 3 n/a h/a BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) Weight: 8 lb FT = 0% LUMBER - TOP CHORD 2x4 SIP No.2 BOT CHORD 2x4 SP No.2 BRACING- LOAD CASE(S) TOP CHORD Standard Structural wood sheathing directly applied or 2-6-15 cc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 cc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation quide. REACTIONS. All bearings 0-8-13 except at --length) 3=Mechanical, 4=Mechanical. (lb) - Max Horz 2= 46(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 3, 5 except 2=-129(LC 8) Max Gray All reactions 250 lb or less at joint(s) 3, 2, 5, 4, 2 FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.0psf; h=28ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Extedor(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle G-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 5 except at --lb) 2=129, 2=129. 7) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. Julius Lee, RE_ #34869 — 1109 Coastal Bay — Boynton Beach, FL 3343S Job Truss Truss Type �. Qty Ply A0134392 59941 JHA Jack -Open 1 1 Ulb Reference o tional Al ROOF TRUSStS, FOR I MERGE, FL 34946 3.46 F12 21 T1 1 2x4 = 2x4 11 0� 7.600is Oct 3 2014 MiTek Industries, Inc. Fri Nov 07 09:12:39 2014 Page 1 0-9-0 3 1 v a 4 B2 [$ I$ A 0.87 F12 5 3x4 = Plate Offsets X -- 2:0-0-15 0-6-8 2:0-0=8 Ed e 1-0-4 U-U-3 U-U-U LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (lac) I/deft L/d PLATES GRIP TCLL 30.0 Plate Grip DOL 1.25 TC 0.05 Vert(LL) 0.00 6 >999 360 MT20 244/190 TCDL 15.0 Lumber DOL 1.25 BC 0.03 Vert(TL) -0.00 6 >999 240 BCLL 0.0 ` Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 3 n/a n/a BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight: 7 lb FT = 0% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- LOAD CASE(S) TOP CHORD Standard Structural wood sheathing directly applied or 2-3-8 cc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 cc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 0-8-13 except at --length) 3=Mechanical, 4=Mechanical. (lb) - Max Horz 2= 41(LC 8) Max Uplift All uplift 100 lb or less at joint(s) 3, 5 except2=-126(LC 8) Max Grav All reactions 250 lb or less at joint(s) 3, 2, 5, 4, 2 FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=170mph (3-second gust) Vasd=132mph; TCDL=5.Opsf; BCDL=5.Opsf; h=28ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C .Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 5 except at --lb) 2=126, 2=126. 7) "Semi -rigid pitchbreaks with fixed heels" Member end fixity model was used in the analysis and design of this truss. Julius Lee, P.E. #348 9—'1109 Coastal Bay — Boynton Beach, FL 33435 Name: USP Address: STRUCTURAL Customer., CONNECTORS' MITek'Company Canto&. Number. Hangers j.. "MIR L , 0 bi I., im "d T A.6 1.17 2 'if V"; 0.11, i,,.! 1-jor .. 19§ "T gr 5" 6' WK �.b Ij 'amuv"Y J OF T1 JUS24 1881, 655 750 820 510 4-10d (Header) FL821.39, 2. 10d (Joist) 11- 0510.01, '1490 RR 25779 LUS24 670 765 025 4 -10d (Header) 1 1 2 -10d paint) T2 JUS26 3.881, B50 975 low 3.3.3.5 4- 10d (Header) F1.821.42, 4-10d (Joist) 11- 0510.01, RR 25779 LUS26 665 990 1070 h65 4 -10d (Header) 1 4 -10d (lout) TS MSH422 183:4 - 22 - 10d (Face - Face Max Mailing) F1.822.36, 6 -10d (Face - Top Max Nallingy as- 6 -10d (Joist - Face' Max Nailing) 0303,06, 6- 10d (Joist -Top Max Nailing) RR 25836, 4- 10d (Top -Top Max Nailing) 13116-R 7HA422 2245 2245 2245 6 - 16d (Carted Member- face Mount) 6 - 10d (Canted Member - Top Flange) 22 - 16d (Face - pace M6 unt) 2 - 1 6d (Face - Top Flange) 4 - 16d (rap.. Top Flange) THA1422 1835 1835 1835. 2-10dxl-112or2-10dxl-112(Carried Member) 20 - 10d ar2 -10d (Face) 4- Ind (Top) USP Structural Connectors I J J� I�rl M-A-1 ROOF NTRUSSES AFLGRIDACORPORA1710N Important Notes / Please Review Prior to 1) Trusses are to be handled, installed and braced in accordance wit ANSI/TIP 1-2007; WTCA 1-1995 — "Standard Responsibilities in tI Metal Plate Connected Wood Trusses", and "BCSI 1-03 Guide to C Installing, & Bracing of Metal Plate Connected Wood Trusses" publ Institute. Any of this material can be obtained by contacting A-i R also available. 2) All temporary' and permanent bracing design, connection, material 3) Truss designs are for an individual component, not for a truss syste vary from building designers calculated loads. The building design clarifying any discrepancies. 4) If provided by truss manufacturer, any engineered beams provddec information design guides or software provided by the beam manL should verify all loads uplifts, and bearing requirements. Truss mar specifying beams, other than those provided by taus manufacturer. 5) Unless specified, roof trusses are not designed for any additional c 6) On flat surfaces, adequate drainage must be provided to avoid p( 7) It is the builder's responsibility to assure there is adequate room foi plumbing runs to assure they do not interfere with the truss chords. and webs cannot be art. Attic access opening should be located be noted. S) Unless specified, valley framing design, connection, material and It builder. 9) Attached drawings are standard details that cover most installatio provided by the building designer supersede any attached details 10) Trusses are not designed to carry the chimney, cupola, steeple, or 4 Structure should be framed through the trusses to be supported by trusses are designed to carry the structure above all loads and upl designer. Connection of structure to trusses must be provided by ti 11) The specific engineered truss drawings are subject to other terms, c placement plan and/or individual truss design drawings. 12) Trusses are designed to carry ONLY the specified loads on the enc for materials, erection personnel, equipment, whether temporary o unless specified on sealed engineered drawings. Any questions or comments feel free to contact A-1 Roof 4451 St. Lucie Blvd., Fort Pierce, FL 772-409-1010 Office 772-409-1015 Fax Installation: the following standards: Design Process Involving Sod Practice For Handling, hed by WTCA and Truss Plate 3f Trusses. Spanish versions are and labor by others. . Reactions and uplifts may r is ultimately responsible for have been sized using The building designer is not responsible for storage loads. A/C ducts, electrical wiring and Roof and floor:) Truss chords Veen trusses unless otherwise to be supplied by the standards. Structural details er structures unless specified. e foundation. In cases where s MUST be verified by building building designer. ditions, and details on the truss ineered drawings. Point loads permanent, are -not allowed at 772-409-1010. www.AItruss.com T4 TH D26 1781, 2485 2855 3060 2170 - 18 -16d (Face) FLIS285.35 12 -10d x 1-1/2 (Joist) , 06- 092L05, RR 25843 HTU26 2940 3340 3600 1555 II -10d x 1-112 (Carried Member) 20 -10d x 1-112 (Carried Member - Max Nailing) 20 -16d (Carrying Member) ' - 20 -16d (Canying Member- Max Nailing) T5 THD26-2 1781, 2540 2920 33.75 2285 - 18 - I.6d (Face) FL13285.35 12 -10d (Joist) 06- 092L05, RR 25843, 13116-R HHUS26--2 2785 3155 3405 1550 - - - 14 -16d (Face) 6-16d (Joist) I•ITU26-2 2940 3340 3600 2175 - 20 -10d (Carried Member- Max Nailing) 20 -16d (Carrying Member- Max Nailing) 36 THD28 1783. 3865 3965 3965 2330 - 28 -16d (Face) FL13285.35 16 - 2.0d x 1-1/2 (Joist) .O6- 0921.05, RR 25843 HTU28 3020 4340 4660 2140 26 - I0d x 1-112 (Carried Member - Max Nailing) 26 -16d (Carrying Member- Max Nailing) T7 THD28-2 178:4 3950 4540 4935 2595 - - 28*- 16d (Face) FL13285.35 16 -10d (Joist) , 06- 0921-05, RR 25843, .13116-R HHUS28 2 4210 4770 5140 2000 22 -16d (Face) 8 -16d (Joist) HTU28-2 3820 4340 4680 3485 26 -10d (Carrled Member - Max Nailing) 26.16d (Carrying Member- Max Nailing) T8 TH D46 178:4 2540 2920 3175 2285 - - - 18 - 16d (Face) FL13285.35 12 -10d (Joist) , 06- 092L05, RR 25843, 13116-R LISP Structural Connectors HHUS46 2790 3I60 3410 11550 - 14 -16d (Face) 6 -16d (Joist) T9 THD48 1781. 3950 4540 4935 2595 - 28 -16d (Face) FL19285.35 16--10d (joist) . 06- 0921.05, RR 25843, 13116-R HHUS48 4210 4770 5140 4-000 - - 22.16d (Face) 8-1Gd (Joist) T10 TH DH26-2 1881, 3915 4505 4795 2235 - 20 -16d (Face) FL82135, 8 - 16d (Joist) 0921.05, RR 25779, 13116-R HGUS26-2 4355 4875 5230 2155 - , - 20 -16d (Face) 8 -16d (Joist) T11 THDH26-3 1881, -3915 4505 4795 2235 20 -16d (Face) FL821.75, 8 -16d (Joist) 06- 0921.05, RR 25779 HGUS26-3 4355 4875 5230 2155 20 -16d (Face) 8 -16d (Joist) T12 THDH28-2 1881, 6535 7515 8025 2665 - 36- 16d (Face) FL82L77, 10 -16d (Joist) RR 25779, 13116-R HGUS28-2 7460 7460 7460 3235 - 36 -16d (Face) 12 -16d (Joist) T13 THDH28-3 1881, 6770 7785 B025 2665 - - 36- 16d (Face) FL821.77, 12 - 16d (Joist) 06- 0921.05, RR 25779 HGUS28-3 7460 7460 7460 3235 - 36.16d (Face) 12 -16d (Joist) USP Structural Connectors STRUCTURAL CONNECTORS' A MiTek' Comparry Fastener Comparison Table Name: Address: Customer: Contact Number. '-" �:_ _ M=�.�--•'--�-'.= r��£,�: �:�.�.:==i• ' _ _ .t_y.ga.:Fci'_-'_--r.`,•.•=� i�� ±,-_--'— :iz.�.•+,... cno.�<:%tJ.__ -- k',�4'k`-c�-�'`••-�._- V',' - -_:,'may-^-.4 :ti?�_^ 4'r`�r_�-..=:rrt'+-`�� �x`"'`i:.'-s:u.v t=?S+L•'�s'- ::•x,a;4a•:.- �--x•:•?•-rciCa�nnectnr ischedaie= _�..��y ._'.'-� _ _ _-�.'a�.=r-�..� r�..r�=`=-: - - z.lu.._ae�-..c-.--_ :%Jr,1i:.--�:.`•�-�.is.'a'-=4:5 ...c-+t'•"-'y'-.. �3'i-ta-e?+.�-:•G.�9-rs"':i-•ch.: a.'c�•3�•--�'=T.`'`..vC°'`^'F`._'•T'*--�_-.^--.-... �^'•. __�sd��'.,._,:..:fM ^ti..�.-•.`�L`yl'ri?r. .•p. ,ry t;ra- _ .�[aiielc �ilSP•'.Stocl�iliro_ R wredF"astene o-. �;Rerence°Nio Q- - +�=Requ�iad:Fasfene ==- x �r . _ _...:=�-:...-ti-l`.ei• r-- -� - TI JUS24 4-lad (Header) LUS24 4-I0d (Header) 2 - lad (Joist) 2-10d (Joist) - TIO THDH26-2 20 -16d (Face) HGUS262 20 -16d (Face) 8 -16d (Joist) 8-16d (Joist) - T11 THD H26-3 20 -16d (Face) HGUS26-3 20 -16d (Face) 8 -16d (Joist) 8 -16d (Joist) - T12 THDH28-2 36 -I6d (Face) HGUS28-2 36-16d (Face) 10 - I6d (Joist) 12-16d (Joist) - T13 THDH28-3 36 -16d (Face) UGUS28 3 36 -16d (Face) 12 -16d (Joist) 12 - I6d (Joist) - T2 JUS26 4 - lad (Header) LUS26 4-10d (Header) 4 -10d (Joist) 4 - IOd (Joist) - T3 MSH422 22 -10d (Face - Face Max Nailing) THA422 6 -16d (Carried Member- Face Mount] 6 - lad (Face - Top Max Nailing) 6-10d (Carried Member - Top Flange) 6 - lad (Joist - Face Max Nailing) 22 -16d (Elite - Face Mount) 6 - lad (Joist -Top Max Nailing) 2 -16d (Face - Top Range) 4 -10d (Top -Top Max Nailing) 4-16d (fop - Top Flange) - T4 THD26 18 -16d (Face) HTU26 11- IOd x 1-1/2 (Carried Member) 12 -lad x 1-1 j2 (Joist) 20 -10d x 1-I12 (Curried Member - Max Nailing) 20 -16d (Ca►ryLag Member) 20 -16d (Carrying Member - Max Naith7g) - TS THD26-2 18 -16ci(Face) RHUS26-2 14 -16d (Face) 12 -10d (Joist) 6-16d (Joist) - T6 THD28 28-16d(Face) HTU28 26-10dx1-1l2(Carried Member - 16 - lad x 1-2/2 (Joist) Max Nailing) 26 -16d (Carrying Member - Max Nailing) - 77 THD28-2 28 -16d (Face) HHUS28 2 22-16d (Face) 16-10d (Joist) 8- I6d(Joist) - T8 THD46 18 -16d (Face) HHUS 6 14-16d (Face) 12 -lad (Joist) 6=16d (Joist) - IT9 I THD48 128 -16d (Face) UHUS48 22 -16d (Face) 16 - led (Joist) 8 -16d (Joist) USP Structural Connectors I PAddress: STRUCTURAL Customer: CONNECTO" A Wek•Company Contact: Number. JUS24 (Qty.- 1) THDH26-2- (Qty.' 1) THDH26-3 (Qtjr 1) THDH28-2 (Qty.1) THDH28-3 (Qty: 1) JU526 (Qiy.' 1) :- flange �. 97 K,ght IVflange MSH422 (Qty. 1) THD26 (Qty.- 1) THD26-2 - Q Left E flange IMP 4 Loft Le flar+ge 5 o fir.•: ► r '~ •ate . i v5- •r . Might flange flange THD28 (Qty.1) THD28-2 (W. 1) THD46 (Qty-1) USP Structural Connectors j M Adddresw Customer: STRUCTURAL CONNECTORS` Li AMiTak'Company Contact Number: flange `M� ?. � wP?` tL J D iV ht flange THD48 (gty.•j USP Structural Connectors I A r.1 t t ID79114 TYPICAL. HIPJACK CONNECTION 7rSTBK MAX 55 RSF MAX ROOF LOAD MLM 170 MPH EX C H=2& MAX `'"1 �' r• 4 24 t a. r1_2 r314 ML . �� 3 2 3 m4@ ED w4um 11 14 Kafla� .3L�. all comerjack with 2-IMwe rmb i 11'11 Btu 1s 7 ML43 1.5X n NARM 1s NAILED NAILD 2-1 rd toe nail 24- strap 6-1 Qdz 1 S' each end LOADING (p-p SPACING 2 0 0 CM DEFL In (Ioc) lldefi Ud PLATES GRIP ' TOLL 30A Plates Increase t 25 TC 0.71 Vert(LL) -DM 6 7 s999 360 MIM 244i190 TCDL 15.0 Lumber Increase 1.25 8C CL49 VeWL) -0.09 6-7 >099 240 I BCLL 0.0 ' Rep Stram Incr NO WS 0.50 Hoa(rL) 0.01 6 nra nia BCDL 10.0 Cork FRC2010iTP121G7 (Matrix M) Weight' lb FT - 0 6 CHORD 2s4 SYP M 38 CHORD 2(4 SF No-2 S 2x4 SP No-3 BRACING TOP CHORD Structural vmc)d shealWng diredyappEed or 6-0-0 oe purlins. ' BOT CHORD StrucLrral mood sheattdng dir=UyappEed or B-9-4 oc bradng. MTek recommends Thai Stablizem and mquired cross bradng be Installed during truss erection, in accordw= with b'tabilizer Installation ouide :TIONS ptrsIZe) 4-1B&Mechanical, 2-6=0.10-15 (min.0-1-8).6-362rMechanical Max Horz2-308(LC 4) Max Upi1ft4--156(LC 4). 2--382(LC 4), 6--159(LC 8) Max Grav4-219(LC 2)< 2-73-1(LC 2). S-412(LC 2) :ES (lb) - h1ax: ComplMax Tea -All forces 250 (Ib) oriess- excentwhen shown. CHORD 2-1 t.-933i635,11-12- 85fi+307, 3 12- 845f303 CHORD 214--6B1/84B, 14-15--j39i8 =8, 7-15- 439/648, 7-15--439/84% 6 16- 439" S 3-6--916475 WInd:ASCE 7-10;170mph (3-second gust) Vasd-132nVh,,TCDL-S.Opsi; BCDL-S.Opst; h-2alt; Ca. li; ExpC; Encl., GCpl.0.1B; MWFRS (envelope); cantilever left and right exposed; Lumber DOL-1.33 plate grip DOL-1.38 This truss is not designed to support a ceiling and is not Intended for use vdlere aesthetics are a consideration. Plates checited for a plus or ndrurs 0 degreeroladon about itscenter- This lass has been designed fora 10.0 psf bottom chord Eve load noncaneurrent with any other five loads. 'This truss has been designed fora five load of 20.0psf an The bottom chord In all areas where a rectangle 3-6-0 tall by 2-0-0 widevdE fit between the bottom chord and any other members. ``lllltl(ff//�! Ar " N 34869 " „n L[1 STATE OF �i ORtQP`. 0 1109 CO-ASTAL BAY BOYNTON BC,FL 33435 10/20/12 TYPICAL ALTERNATE BRACING DETAIL 'FOR EXTERIOR FLAT GIRDER TRUSS 12 TRUSS -24' c.c. UPLIFT CONNECTION SEE R 00F TRUSS EXTERIOR FLAT 0 4 12d MAX 30'w (.21 --5") \\��titlltlltrrl,, X 2 Sp BOTH FACES Yam` � ! M P�'a' C�I,I H %� •' STATE OF ;'•��: rj ..•• ti 1109 COASTAL BAY BOYNTON BC,FL 33435 10/29/22 ' STANDARD PIGGYBACK TRUSS ST PIGGY-PERP. EEBRUARY 14, 2D12 CONNECTION DETAIL (PERPENDICULAR) N1ek Industries. Chesterfield, MO Page i of 1 MAX MEAN ROOF HEIGHT'= 30 FEET 0 oQ BUILDING CATEGORY ]I WIND EXPOSURE B or C WIND DESIGN PER ASCE 7-98, ASCE 7.02, ASCE 7-05 100 MPH (MWFRS) WIND DESIGN PER ASCE ?-10125 MPH (MWFRS) kt7ek Industries, Inc. DURATION OF LOAD INCREASE FOR WIND LOADS:1.60 DETAIL IS NOT APPLICABLE FOR TRUSSES TRANSFERING DRAG LOADS (SHEAR TRUSSES ADDITIONAL CONSIDERATIONS BY BUILDING ENGINEERIDESIGNER ARE REQUIRED. PIGGY-BACKTRUSS (CROSS-SECTION VIEW) Refer to actual tim s design drawing for additional piggyback truss Wormaaon. NEARSIDE THIS DETAIL SHALL BE ONLY USED FOR RESISTING A VERTICAL WIND UPLIFT UP TO 140 LBS MAXIMUM AT EACH CONNECTION POINT. BUILDING DESIGNER IS RESPONSIBLE FOR THE LOAD EXCEEDING THIS LIMITATION AND/OR IN OTHER DIRECTIONS. ATTACH PIGGYBACKTRUSS TO BASE TRUSS WITH (2) -16d (0-131" X3-5") NAILS TOENAILED. FAR SIDE FLATTOP CHORD OF BASE TRUSS BASE TRUSS (SIDE VIEW) Refer to actual truss design drawing for addit]onal base truss information. NOTES FOR TOE -NAIL: 1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 30• DEGREES WiTHTHE MEMBER AND STARTED 1/3 THE LENGTH OF THE NAIL FROM THE MEMBER END AS SHOW1% 2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCHASTO AVOID UNUSUAL SPLITTING OFTHE WOOD NOTES FOR TRUSS: 1. THIS DETAIL IS VALID FOR ONE -PLY PIGGYBACK TRUSS ONLY: 2_ THE CHORD MEIv1BER OF PIGGYBACK AND BASE TRUSSES MUST BE SOUTHERN PINE OR DOUGLAS FIR -LARCH LUMBER: 3. THE SPACING OF PIGGYBACK TRUSSES AND BASE TRUSSES IS 2 FT OR LESS: 41 THE-PIGGYBACKTRUSSES SHOULD BE PERPENDICULAR TO BASE TRUSSES. 5. PIGGYBACK TRUSS MAY NOT CANTILEVER OVER BASE TRUSS OR HAVE AN OVERHANG-, WHICH WILL CREATE A HIGHER UPUF r AT CONNECTING POINT. S. or ` * ' N 34869 r � LU �0 , STATE OF 1109 COASTAL BAY BOYNTON BC,FL 33435 '10/19/12 FEBRUARY 14, 2012 Standard Gable End Detail' SHEET 2 - O M7ek industries. Cheerfiet<'. MO Page 2 of 2 ALTERNATE DIAGONAL BRACING TO THE 80TTOM CHORD o� Trusses Ca 24" o.c. HORIZONTAL BRACE 2r5 DIAGONAL BRACE SPACED 49- O.C. (SEE SECTION A -A) ATTACHED TO VERTICAL WITH ..) -1 Sd TrACHSD Mt i ek Indus rles, Inc. Roof Sheathing-� , TOBLOCMON NG WfWIRE SAND AOMMMON TO BLOCh'1NG tyfi•H (S) -10d COMMONS. � 1-3' THE RESPO,YSIBIUFYOFTHEBLDGDESIGNER OR PRQIECT ENGINEERWRCHTECTTO DESIGN THE NAIL DIAGONAL 6RACETO ING DIAPHRAGMAND ITS ATiACHMENTTOTHE RLIN WITH TWO16d NAILS >-SESTO RESISTALL OUT OF PLANE LOADS THAT ` RESULTFROM THE BRACING OFTHE GABLE ENDS 2X 4 PURLW FASTENED TO FOUR TRUSSES WITH TWO 16d NAILS EACH. FASTEN PURLIN TO BLOCI.9NG WliW016d NAILS (MIN) Diag. Brace at 113 poiTlts , \ \ PROVIDE 2x4BLOCINTNGBETWEEN THETRUSSES THE AND - it deeded ON EITHER SIDE ASSUPPORTING NOTEX TOENAIL SLE OCIONNG S TO TRUSS WITH (2) _ 1 Od NAILS AT EACH END. ATTACH D1A3014ALBRACETOBLOCmG WnH (s}-10d COMMON WIRE NAILS. End Wall j-I CEILING SHEATHING BRACING REQUIREMENTS FOR STRUCTURAL GABLE TRUSSES STRUCTURAL GABLE TRUSSES MAYBE BRACED AS NOTED: STRUCTURAL METHOD 1 : ATTACH A IAATCHING GABLETRUSS TOTHE WSIDE GABLE FACE OFTHE STRUCTURAL GABLE AND FASTEN PER THE FOLLOWING NAILING SCHEDULE. METHOD 2:ATTACH 2" SOABSTOTHEFACEOFEACHVERTICAL SCABALONG MEMBER ON'THE STRUCTURAL GABLE PER THE FOLLOWING CAL SCHEDULE. SCABS ARETO BE OF THE SAMIE SIZE, GRADE VEMi AND SPECIES ASTHETRUSS VERTICALS NAILING SCHEDULE: - FORWIND SPEEDS 120 MPH (ASCE7-48, 02, 05),150 MPH (ASCE7-10) OR LESS, NAILALL MEMBERS WITH ONEROW OF10d (131- XX) NAILS SPACED 13-O.C. - FOR WIND SPEEDS C-REATER 120 MPH (ASCE 7.98, 02, M.150 MPH (ASCE 7-10) NAILALL MEMBERS WITH TWO ROWS OF10ii (.131- X3-) NAILS SPACED 6 O.C. (2X 4 STUDS MINIMUM) MAXIMUM STUD LENGT S ARE LISTED ON PAGE 1. ALL BRACING METHODS SHOWN ON PAGE 1 ARE / VAUD AND ARETO BE FASTENED TO THE SCABS OR 4VLAYED STUD VERTICAL STUDS OFTHESTANDARD GABLETRUSS / OBI THE 1NTERIOR SIDE OFTHE STRUCTURE OTU r AN ADEQUATE DIAPHRAGM OR OTHER METHC pF, RrCING GABLETRUSS BEPRESENTTOPROVIDE FULL.LATERAL EjRpb)�i6F CHORD TO RESIST ALL OUT OF PLANE 'dA E ING a / IN THIS MAIL IS FOR THE VERTIC`L1LS jJp yF--`: . - / N 34869 STATE OF if •.•.RLORIQA.= - ����� 1109 COASTAL BAY BOYNTON BC, FIB 3343E NOTE. THIS DETAIL IS TO BE USED ONLY FOR' STRUCTURAL GABLES WITH INLAYED SYIDS. TRUSSES W ITHOUT INLAYED STUDSAFIENOTi ADDRESSED HERE STANDARD GABLETRUSS 1 MUST I FEBRUARY 14, 2Q12 STDARD PIGGYBACK I TRUSS CONNECTION DETAIL I ST:PIGGY PLATE I a Mi i ek Industries, Inc. This detail is applicable for the following wind conditions: ASCE 7-98, ASCE 7-02, ASCE 7 05, ASCE 7-10 Wind Standards under all enclosure and exposure conditions as long as no uplift exceeds 3777 lbs. Refer to actual piggyback truss design drawing for upld£s. NOTE: This aetal is valid for one ply busses spaced 24" o c. or less. PIGGYBACKTRUSS Refer to actual truss design drawing for additional piggyback truss information. SPACE, ACCORDING TO THE MAMMUM SPACING ONTHE TOP CHORD DFTHE BASE TRUSS (SPACING NOT TO EXCEED 24r O.C. A PURLIN TO BE LOCATED AT EACH BASE TRUSS JOINT. Mirek kidistries, chart C id, MD Page 1 of 1 Attach piggyback truss to the base truss with S'x8' TEE -LOCK Muhl -Use connection plates spaced 48" a.c. Plates shalt be pressed into the piggyback truss at 48- o.c. staggered from each face and nailed to the base Loss with four (4)- Ed (1.5"x0.099') riails in each plate to achieve a maximum uplift capacity of 3T77 lbs. at each 3"x8' TEE -LOCK Multi -Use connection plate. (Minimum of 2 plates) Attach each purlin to the top chord of the base truss. (Pur(ins and connection by others) BASE TRUSS Refer to actual truss design drawing for additional base truss information. N "X%%1111111111 ' 7(r : N 34869 � xr ' = Z7LU Cl: __ - STATE OF \?�� �i - •- FCORIOP.-��' �� 1109 COASTAL BAY BOYNTON BC,FL 33435 10/19/12 FEBRUARY 14. P-012 I TRUSSED VALLEY SET DETAIL i ST VALLEY SYP a Mi ak Industries, Inc. SECURE VALLEY TRUSS W/ ONE ROW OF 1 sd NAILS 13" O.C. . GABLE ENO. COAWON TRUSS OR GIROERTRUSS MTek lMuskl ChesbufieW. MO Page 1 of 1 GENERAL SPECIFICATIONS 1. NAIL SIZE - 3.5" X 0.131" =16d 2. INSTALL VALLEYTRUSSES {24" O.C. MIMUM AND ` SECURE PER DETAIL A 3. BRACE VALLEY WEBS IN ACCORDANCE WITH THE INDIVIDUAL DESIGN DRAWINGS. 4. BASE TRUSS SHALL BE DESIGNED WITH A PURLIN SPACING EOUILWANTTO THE RAKE DIMENSION OF THE VALLEY TRUSS SPACING. ATTACH 2A CONTINUOUS NO 2 SYP TO THE ROOF W/TWO 15d (0.131' X S.S") NAILS INTO EACH BASE TRUSS. DETAIL A (MAXIMUM V SHEATHING) N_T.S. NON TRUSS 5 WIND DESIGN PER ASCE 7.98, ASCE 7-03; ASCE 7-05 12G MPH WIND DESIGN PER ASCE7-14 150 MPH MAX MEAN ROOF HEIGHT° 30 FEET ROOF PITCH - MINIMUM 3AZ MAXIMUM 1nA2 CATEGORY It BUILDING EXPOSURE C OR B MIND DURATION OF LOAD INCREASE : 11g10I I 1 I' �i` MAX TOP CHORD TOTAL LOAD - RAP MAX SPACING - 29 O.C. (BAS -AN MINIMUM REDUCED DEAD 1*D Fp F-•..: h /� ON THE TRUSSES ' Mass '� ` O� 10 19/12 W� STATE OF •: . � 11/11 QNA 1 �; •�• 1109 COASTAL BAY BOYNTON BC,FL 33435 .k r,;. ,i I OCTOBER 1, 2006 I LATERAL TOE -NAIL DETAIL I ST-TOENAIL SP I �Jaa a MTek Industries. Inc. MTeklndusbies.Cheste:fieid.MO Page 1 oF1 NOTES: 1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 45 DEGREES WITH THE MEIVIBER AND MUST HAVE FULL WOOD SUPPORT (NAIL MUST BE DRIVEN THROUGH AND E?0T AT THE BACK CORNER OF THE MEMBER END AS SHOWN. ? THE END DISTANCE EDGE DISTANCE. AND SPACING OF NAILS SHALL BE SUCH AS TO AVOI D UNUSUAL SPLITTING OF THE WOOD. 3. ALLOWABLE VALUE SHALL BE THE LESSER VALUE OFTHETWO SPECIES FOR MEMBERS OF DIFFERENT SPECIES. OE-NAIL SINGLE SHE ;R VALUES PER NDS 2001 (ibinail) rE IAM. SYP OF HF SPF SPFS .131 88.0 90.5 699 BOA 593 t35 93.5 956 74.2 785 63.4 .162 108.8 99.6 BSA 84.8 739 .128 74.2 67.9 58.9 57.6 503 .131 759 69.5 603 59M 51.1 .148 Rl4 745 54.6 63.2 52.5 VALUES SHOV1W4 AF` CAPACITY PER TOE -NAIL APPLICAELE DURATION OF LOAD INCREASES MAY BE APPLIED. EXAMPLE (3)-16d NAILS (.162" clam.x 3SI WITH SPF SPECIES BOTTOM CHORD Forloed duration increase of 1.15: 3 (nalls) X 84.5 (Ib/nail) X 1.15 (DOL) = 291.5lb Maximum Capacity ANGLE MAY VARY FROM 30, TO 60' 45.00' ANGLE MAY VARY FROM 30° TO 601 THIS DETAIL APPLICABLE TO THE THREE END DETAILS SHOWN BELOW VIEIAS SHOWNARE FOR ILLUSTRATION PURPOSES ONLY SIDE VIEW (W.l4) 2 NAILS NEAR SIDE NEARSIDE 45.00° SIDE VIEW (2;b7 3 t141LS NEARSIDE NEAR SIDE NEAR SIDE ANGLE MAY VARY FROM 30' TO 60° 45.000 `,,11t11111lr!/,t N 34869 `� 10/29/3-2 LEI Z STATE OF LORID 1109 COASTAL BAY BOYNTON BC,FL 33435 OCTOBER 1, 2006 � co MTek Indushies, Ina SIDE VIEW NEAR FAR. SIDE UPLIFT TOE -(MAIL DETAIL ST-TOENAIL UPLIFT1 Mi rd; ►ndustries, Chesarfietd. MO - Page 1 of 1 NOTES: 1. TOE NAILS SHALL BE DRIVEN AT AN ANGLE OF 30 DEGREES WITH THE MEMBER AND STARTED 1/3 THE LENGTH OF THE NAIL FROM THE MEIvEER END AS SHOWN. 2. THE END CISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UIlLISUAL SPLITTING OF THEV`IOOD_ 3. ALLOWABLE VALUE SHALL BE THE LESSER. VALUE OFTHE BOTTOM CHORD SPECIES OR TOP PLATE SPECIES FOR MEMBERS OF DIFFERENT SPECIES. TOT OF SIDE VeAS SHOWN ARE FOR ILWSTRATION PURPOSES ONLY TOE -NAIL WITHDRAWAL VALUES PER NDS 2001 (lb/nail) DIAM. SIP DF HF SPF SPF-S cD .131 56.5 4S.1 315 293 20.3 O .135 I 69.3 47.5 I 32.6 3113 29.9 in .162 72.3 57.9 39.1 3S.a 25.1 m Z 128 53.1 419 26.7 27.0 164 Jo .131 54.3 429 29.3 37.7 18.8 n 148 61 A 48.3 33.2 31.3 21.3 to (9 .120 45.9 1 3 '24 A 23A 159 71 O .128 49.0 38.6 25.5 25.0 17.0 b .131 50.1 39.5 27.1 25.6 17.4 .143 55.5 44B 30.61 26.9 19.6 VALUES SHOVK4 ARE CAPACITY PER TOE -NAIL. APPLICABLE DURATION OF LOAD INCREASES MAY T3EAPPLIED. EXAMPLE (3) - 16d NAILS (.167 diem. x 3.5-1 WITH SPF SPECIES TOP PLATE ForWrid DOL of 133: 3 (nails)X36.8 (1b/nail)X 1,33IDOL forwind)= 146.8lb Maximum Allowable UpfiftReactionDue To Wind For Wrid DOL of 1.60. 3 (nails) X 36.8 (Ib/nal) X 1.60 (DOL for Wind) =176.6Ib Maximum Allowable Uplift Reaction Due To Wind If the uplift reaction specified on the Truss Design Drawing is more than 146.8 lbs (176.61bs) another mechanical uplift connection must be used. USE (3) TOE -NAILS ON 2A BEARING WALL USE (4)TOE NAILS ON 24 BEARING WAIL END VIEW 10/19/12 GENsF'�F�'�� -� % Luz O ' STATE OF Z/Irl f111 1109 COASTAL BAY BOYN'TON BC,FL 33435