Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Project Information
Rel(ml � # - I y►()- o-�l� * wrightsofte Project Summary Entire House QUICK CALCS, INC. 317 ST. LUCIE LN., FORT PIERCE, FL 34946 Phone: 7724666799 Fax 7724666796 Email: QUICKCALCS@AOL.COM For: WILLIAMS RESIDENCE, MEL-RY CONSTRUCTION 2019 NETTLES, JENSEN BEACH, FL Notes: Weather. W Palm Beach, FL, US Winter Design Conditions Outside db 47 of Inside db 70 °F Design TD 23 °F Heating Summary Structure 16281 Btuh Ducts 20 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 16301 Btuh Infiltration Method Construction quality Fireplaces Simplified Average 0 Heating Cooling Area (ft2) 1083 1083 Volume (ft3) 10290 10290 Air changes✓hour 0.45 0.23 Equiv. AVF (cfm) 77 39 Heating Equipment Summary Make Trade Model AHRI ref Job: Date: Sep 19, 2014 By: Summer Design Conditions Outside db 90 °F Inside db 75 of Design TD 15 °F Daily range L Relative humidity 50 % Moisture difference 59 gr/lb Sensible Cooling Equipment Load Sizing Structure 12972 Btuh Ducts 24 Btuh Central vent (0 cfm) 0 Btuh Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 12372 Btuh Latent Cooling Equipment Load Sizing Structure 4068 Btuh Ducts 7 Btuh Central vent (0 cfm) 0 Btuh Equipment latent load 4075 Btuh Equipment total load 16447 Btuh Req. total capacity at 0.70 SHR 1.5 ton Cooling Equipment Summary Make Rheem Trade RHEEM 14AJM SERIES Cond 14AJM19 Coil RHLL-HM2417++RCSL-H"2417 AHRI ref 5550186 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 0 kW Sensible cooling 13090 Btuh Heating output 0 Btuh Latent cooling 5610 Btuh Temperature rise 0 °F Total cooling 18700 Btuh Actual air flow 623 cfm Actual air flow 629) cfm Air flow factor 0.038 cfm/Btuh Air flow factor 0. 01& cfm/Btuh Static pressure 0 in H2O Static pressure cO Zin F�9 Space thermostat Load sensible heat ratio �'3! Boldlifalic values have been manually overridden o JC�� Calculations approved byACCA to meet all requirements of Manual J 8th Ed. Wrl htsofta t ^ �EOdle ! 5-MaF O6'86:e 1 9 Right-Suitera� Universal 2013 13.0.01 RSU06101 ��� Page 1 ...ocuments\Wrightsoft WAC\WILLIAMS RESIDENCE.rup Calc = MA Front Door faces: N �vr/ Al wrightsoft Right-M Worksheet Job: Entire House Date: Sep 19, 2014 By: QUICK CALCS, INC. 317 ST. LUCIE LN., FORT PIERCE, FL 34946 Phone: 7724666799 Fax 7724666796 Email: QUICKCALCS@,AOL.COM 1 Room name Entire House M BATH 2 Exposed wall 166.2 It 18.8 It 3 Room height 9.4 ft d 8.0 ft heat/cool 4 Room dimensions 1.0 x 102.0 ft 5 Room area 1097.0 ft' 102.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuh/ft;°F) (Btu ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-4acs _ _ �' 0.143 ii .3.25 , 2.72 ;�, . 488 - 422 �. 1370 1148 . 0 0 0 - 0 1A-clom 1.270 , n 28.83 :" 20.37" 6 0 173 M 0' 0 0. 0 1A-clom " 1.270 - n 28:83 20.37 16 0 471 333 ! 0 _ ' -: 0 ... 0 A 1A-clom 1.270 n 28 83 20.31 25 0 721 509 :' ,' 0 ' U .' 0 11 11D0 0.390 n _ 8.85 "_ 11.78 19 19 166 220 _. 0 0 0 0 V1J 13A4 cs 0.143 ne 3.25 2.72 29 14 46 39 0 0 0 0 -P IA-clom, 1.270 ne 28.83 30.32 15 0 420 442 0 -0 _ 0. V�1 13A-4ocs 0.143 is 3.25 , . 2.72 160 ". , " ; 145 _ 471 394 0 0 . 0 .'0 : 0 I-� 1A-616m,. " .� 1.270 e 28.83 31.14 15 5 432 467 0 ... . 0 " . 0 : 0 V7/ 13A-flocs 0.143 se 3.25 2.72 29 16 50 42 0 0 0 0 O 1A-clom 1.270 se 28.83 22.94 13 10 384 306 0 0 0 0 13A-40cs 0.143 s 3.251 2.72 392 331' . 1075 900 : " 40 " 40 130 : 109 1Aclom ' 1.270 s 28.83, 35.03 6 6 180 219 0 0 0.: 0 lA,clorri 1.270 ':s„ 28.83 20.37 8 8: ". 240 170' 0 0 0 0 1A-clom 1.270 s 28.83 20.37 26 26. 745 526 " 0 0 0 0 1100 0.390 : s 8.85 11.78 ' 20 20 181 240 ..:0 0 0 0 V)/ 13A-40cs 0.143 sw 3.25 2.72 201 174 564 472 111 103 335 280 �L-Cp 1Ac1om 1.270 sw 28.83 20.95 8 8 231 168 8 8 231 168 11D0 0.390 sw 8.85 11.7.8 19 19 166 220 0 0 0 W.,,.,.._. 13A74ocs_.. 0.143 .w. 3.25 " . a 2.72 _ 32 . .. C 16A 30md 0.032 0.73 2.36 ..:::32 534 534 388 1260 102 102 74 241 _.. ... ..... 0.105 ........ '' 2.38 .4.69 .: 859 ........._... .. 859 :_2047 .... -...- . 4030 _ . ..._ . ....0 _........ .. ._._ ... 0 :. .0 .'.. . 0 F 22Atpl 0.989 J. 22.45 0.00 1.097 166 3730 0 102 19 423 0 6 c)AED excursion 0 71 Envelope loss/gain 14355 12313 1192 868 12 a) Infiltration 1926 659 219 75 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 16281 12972 1411 943 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 16281 12972 1411 943 15 Duct loads 10% 0% 201 24 0% O%j 0 0 Total room load 16301 12996 1411 943 Air required (cfm) 623 623 54 45 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsaft Right -Suite@ Universal 2013 13.0.01 RSU08101 2015-Mar-06 OPage 1 age1 ...ocuments%Wrightsoft HVAC%WILLIAMS RESIDENCE.rup Calc = MJ8 Front Door faces: N -�- wrightsoft� Right-J® Worksheet Job: Entire House Date: Sep 19, 2014 By: QUICK CALCS, INC. 317 ST. LUCIE LN., FORT PIERCE, FL 34946 Phone: 7724666799 Fax: 7724666796 Email: QUICKCALCS@AOL.COM 1 Room name LAUNDRY CLST 2 Exposed wall 20.2 ft 2.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 1.0 x 79.0 ft 3.0 x 2.0 ft 5 Room area 79.0 ft2 6.0 ftz Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuh/ft;°F) (Btuh/ft�) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-4ocs 0.143 n 3.25 ' 2.72 72 72 234` 106' 16 16 521 43 1A-clom 1.270 n 28.83 20.37 0 0: 0 0 0 0 0: 0 1A-clom 1.270 n 28.83 20.37 0 0' _ 0 0 0 0 0 0 1A-clam 1.270 n 28.83 20.37 0 0: 0 0 0 0 0 0 11 11D0' 0.390 n 8.85 11.7.8 0 0 0. 0 0 0 0: 0 VN 13A-0acs 0.143 ne 3.25 2.72 0 0 0 0 0 0 0 0 G 1A-clam 1.270 ne 28.83 30.32 0 0 0 0 0, 0 0. 0 13A-4ocs 0.143 a 3;25 2.72 _ 0 0 0 0 0 0 0 0 1Ac1om 1.270. a 28:83 a,31.14 '.: '0 0: 0 0 0' 0 0 0 VV 13A-4ocs 0.143 se 3.25 2.72 0 0 0 0 0 0 0 0 L--G 1A-clom 1.270 se 28.83 22.94 0 0 0 0 0 0. 0 13A flocs';. 0.143 _. 3:25 _ 2:72 0 0 0 0 0 ..0.- 0;; .. 0 .... 0 1Ac1om 1.270' 's 28.83 35.03 b 0. 0 0 0' 0 0 0 1A-clom , 1.270 's 28.83 20.37 0 0, 0'' 0 0 0 0 0 1A-clom 1.270 s 28.83 20.37 0 0. -0 ` 0 0 0 0 0 11D0 0,390 s.. .8,85 11.78 0 0: 0. __,_, 0 0 0 ., 0 0 VI/ 13A-4ocs 0.143 sw 3.25 2.72 89 71 230 192 0 0 0 0 ��Gp 1Aclom 1.270 sw 28.83 20.95 0 0 0 0 0 0 0 0 11 DO _.. _ .._ _. _ ... 0.390 _ sw 8.85 . 11.78 ... 19 ..:. .19 _ .- .,166 . _. _ . 220, .. ....0 ....... .0 ..0 _.. 0 W 13A74ocs 0.143 - w 3.25 - 2.72 0 0 ........0 0. .. 0 C 16A-30md 0.032 0.73 2.36 79 79 57 186 6 6 4 14 C 1713,.6a1 0.105 _.._2.38 4.69 .... _: 0 ._ - 0 0 :...0 . 0 F 22Atpl _ 0.989 22.45 _0.00. 79 6 .... 2 45 0 6 c)AED excursion -51 0 Envelope loss/gain 1139 789 101 57 12 a) Infiltration 234 80 23 8 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 1373 869 124 65 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1373 869 124 65 15 Duct loads 0% 0%1 0 0 16% 36% 20 24 Total room load 1373 869 145 89 Air required (cfm) 52 42 6 4 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. .A WrigYl$SO1Ft 2015-Mar-06 @ Right -Suite@ Universal 2013 13.0.01 RSU08101 Page 2 ...ocuments\Wrightsoft HVAC\W I LLI AM S RES I D ENC E. rup Calc = MJ8 Front Door faces: N r- wrightsoft Right-J® Worksheet Job: Entire House Date: Sep 19, 2014 QUICK CALCS, INC. 317 ST. LUCIE LN., FORT PIERCE, FL 34946 Phone: 7724666799 Fax 7724666796 Email: QUICKCALCS@AOL.COM 1 Room name BEDROOM MASTER BEDROOM 2 E)qosed wall 10.0 ft 11.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 5 Room dimensions Room area 10.0 x 100.0 f12 10.0 ft 12.0 x 132.0 ft2 11.0 ft Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2--°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-flocs 1A-clom 1A-clom 0143 1.270 1.270 _'6" -n n ., 28.83 2883 2 72 20.37 `20.37 .. ..80 0 :0 65 0 0. �" 211 0 01 ,_.. :. . 0 0 , 0 0> 0' ... 0 0 0 . .. .: 0 0: 0 0 0 11 - 1A,c1om_ 11D0 1.270 0.390. n n 28.83 .:8.85 2037 ...:11.78 15 A `. :_ :0 0 432 0 305 0 0 0 0 0 , 0: - 0 0 0 VV C 1� 13A-4ocs 1Ac1om , 13A-4ocs 0.143 1.270 0.143 ne ne. oe'' 3.25 28.83 3.25 2.72 30.32 2.72 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0,- 0 0 0 0 ' .Cr 1Aclom s .___ " . 1.270 '-a 28.83 �- 31:14 'o ,0 '. 0 .._..'�:,.,0 - 0 __ .�'._.._... 0 : 0 - 0 0 U)1 13A-4ocs 0.143 se 3.25 2.72 0 0 0 0 0 0 0 0 -G 1Aclom 13A40cs 1A-clom 1.270 0.143 1.270 ._ se s s ...28.83- 3.25 ' 28.83 22.94 2 72 35.03 0 0 0 .- , ` : . 0 0 0 _ 0 0 0 .. 0 --- 0 0 -- -_ -_ 0 8,8 0 . .. _.. 0 73 0 - _ __. 0 237 0 0 198 0 1A,clom 1.270 s 28.83 20.37 0 0 0 0 0' 0 0 0 1A-clorn . 1.270 s 28.83 , :20.37 0 -0_ 0 0 15' 15_ 932' 305 ' �L-Gp 11D0-_ - . 13A-4ocs 1Aclom 0.390 0.143 1.270 s sw sw 8:85 3.25 28.83 2.72 20.95 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W C 11D0. .._......, . 13A-0ocs .. 16A-30md 0.390..sw. 0.143 0.032 w 8.85 .. 3.25 0.73 11.78 2.72 2.36 0 0 100 0 0 100 .- 0 0,._._..: 73 __.-. 0 0 236 ......_.... _.0 _0:..... 132 0 0,. 132 0 0 96 0 0 311 C 97116a1: 0.105 r. ... 2.38 4.69 0 0 0 0, ... "0" 0 0, 0 F. 22A-tpl 0.989 22.45 0.00 100 10 225 0 132 11 247 0 6 c)AED excursion -4 -5 Envelope loss/gain 941 713 1012 810 12 a) Infiltration 116 40 127 44 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 1056 753 1140 854 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1056 753 1140 854 Duct loads 0% 0% 0 0 0% 0%1 0 0 r Total room load 1056 753 1140 854 Air required (cfm) 40 36 44 41 Calculations approved bvACCA to meet all reouirements of Manual J 8th Ed. 'k wrighltsoft Right -Suite@ Universal 2013 13.0.01 RSU08101 2015-Mar-06 0P1age3 ...ocumentslWrightsoft HVACIWILLIAMS RESIDENCE.rup Calc = MJ8 Front Door faces: N -r- wrightsoft' Right-JO Worksheet Entire House QUICK CALCS, INC. 317 ST. LUCIE LN., FORT PIERCE, FL 34946 Phone: 7724666799 Fax: 7724666796 Email: QUICKCALCS@AOL.COM Job: Date: Sep 19, 2014 By: 1 Room name M CLST HALL 2 Exposed wall 2.0 ft 0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 12.0 x 2.0 ft 3.0 x 9.0 ft 5 Room area 24.0 ft2 27.0 ft2 Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuh/ft2-°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 1$ .: A flocs 0.143 . n 3:25 2:72 0...0 . 0 : 0 0 - - 0 - 0 0 1A ciom 1 270 , n 28:83 20.37 .0 0 0 0,.° 0 := . 0 0 0 1Ac1om.' �. >:1270 ;-gin; 28.83 ° 20.37 .', ;;0 <0 'e p 0 0 0', 0 0: 0. 1A,clom' 1.270 n 28.83 20.37 0 _ 0' 0 0 ` 0` 0 0 0 11 11DO 0.390 n 8.85 11:78 :' 0 _: 0 0'_ .. 0'„ . 0' 0 0 0 tVt/ 13A-40cs 0.143 ne 3.25 2.72 0 0 0 0 0 0 0 0 1A-c1om, 1.270 ne, 28.83 30.32 0 0 0 -. 0 _ V 13A-4ocs. 0.143 .e - 3:25 2.72 . 0 ' 0 0' .. ..... 0 0 0. 0 Q G:IA-clam. A270 e- 28.83 31.14 A °' 0 0 ;0 = : 0 - :.- .. 0 . 0 0 V+/ 13A-4ocs 0.143 se 3.25 2.72 0 0 0 0 0 0 0 0 I-G 1Ac1om 1.270 se 28.83 22.94 0 0 0 0 0 0 0 0 13A4ocs 0.143 s 3.25. 2.72 16 18: 52 43 0 0 0 0 IA-c1om 1.270 s 28.83 35.03 0 0 0 0 0 0 0 0 IA-ciom 1.270 :s 28.83 20.37 0 0 0 0 0 0 0 0 1A-clom 1.270 s 28.83 20.37 0 0' 0 0! 0' 0 0 0 11DO 0.390 ;s 8.85 11.78 0 0 0 0! 0' 0 0 0 V�1 13A-4ocs 0.143 sw 3.25 2.72 0 0 0 0 0 0 0 0 1Ac1om 1.270 sw 28.83 20.95 0 0 0 0 0 0 0 0 11D0. 0.390 sw 8.85 11.78, 0 0 0 0 0 0. 0. 0 W:::_ ,. 13A�ocs.-_ 0.143. w:. .. 3.25 -2.72.-._.. -.0 0.._ OM 0 :-:�_.._0,�-..-.. 0..., 0- ..... 0, C 16A-30md 0.032 0.73 2.36 24 24 17 57 27 27 20 64 E 1713-6al ..:. .. 0.105 :: .. 2.38 4.69 .: _: '0 ... _; . 0 ... ..:. 0: ..0I..... ..0 I... .__.._ 0 _.....: 0 :... 0 F 22A-tpl 0.989 ._ 22.45 0.00 24 2 45 0 27 0 0 0 6 c)AED excursion -1 0 Envelope loss/gain 114 99 20 63 12 a) Infiltration 23 8 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 137 107 20 63 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 137 107 20 63 15 Duct loads 0% 0% 0 0 0% 0% 0 0 Total room load I I I 1371 1071 I I 20I 63] u Air required (cfm) 5 5 1 3 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoft` 2015-Mar-06 08:43:11 �4GGA Right -Suite® Universal 2013 13.0.01 RSU08101 Page 4 ...ocumentslWrightsoft HVAC\WILLIAMS RESIDENCE.rup Calc = 10J8 Front Door faces: N - F wrightsoft, Right-JO Worksheet Entire House QUICK CALCS, INC. 317 ST. LUCIE LN., FORT PIERCE, FL 34946 Phone: 7724666799 Fax 7724666796 Email: QUICKCALCS AOL.COM Job: Date: Sep 19, 2014 By: 1 Room name GUEST BATH GREAT ROOM 2 Exposed wall 9.0 ft 45.0 ft 3 Room height 8.0 ft heat/cool 10.7 ft heat/cool 4 Room dimensions 7.0 x 9.0 ft 1.0 x 318.0 ft 5 Room area 63.0 ft2 318.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuh/ft;°F) (Btu ft) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V 13A-40cs 1A,c1om 0.143 1.270 6 n S.25 28.83 _2.72 20.37 -72 6 _66 0 .214 173 " 179 122 162 0 " 136 0 440 0 369 0 1Aclorn 1.270 n 28.83.. .20.37 0 0. 0 0' 16 0 471 333 1A,clom 1.270 n 28.83 20.37 0 0 0 0 0 0 0 0 11 11DO . 0.390 n 8.85 11:78, 0 0 0 .. 0' 0 0 0 0 V+/ 13A-flocs 0.143 ne 3.25 2.72 0 0 0 0 0 0 0 0 t13A-4ocs 1Ac1om 1.270 0.143 ne a 28.83 3.25 30.32 2.72 0 0 0 0 0. 0 _. 0 0 0_ 112 0 112 0, 364 0 304 G 1Ac1om .1.270 a 2883 31.14 • 01 0 0 _ 0 0 0 = - 0 0 13A-40cs 0.143 se 3.25 2.72 0 0 0 0 0 0 0 0 1.270 se 28.83 22.94 0 0 0 0 0 0 0 0 _1Ac1om 13A-40cs .IA-c1om - _.0.143 1.270 s s 3.26 28.83 w, ; _ 2'72 35:03 0 0 0 .0 : 0' 0 ' 0 .. 0 ' ` 96 0 ' 67 0 ' T 218 0 183 0 1Ac1om 1.270 s 28:83 .20.37 0 0 ` 0 0 8 8 240 170 IA-c1om 1.270 s 28.83 20:37 0 0' 0 0 0 0 0 0 1100 0.390 s 8.85 .. 11.78 0 . 0 0 .0 20 20 ... 181 240 V�/ 13A-40cs 0.143 sw 3.25 2.72 0 0 0 0 0 0 0 0 1Aclom 1.270 sw 28.83 20.95 0 0 0 0 0 0 0 0 I�-Gp 11D0 0.390 11.78 0 0 0 ... 4 0 0 W C 13A-4ocs 16A 30md 0.143 0.032 .sw. w._. .....8.85 ...._:3:25 0.73 _ 2J2.. 2.36 -, _..'0. 63 , _... _ 0 63 :-._.... 0 46 _ .0 149 .. .0 0 ....... 0 .. Q: 0 0 1 C . .17B 6a1:. ...': 0.105 . 2.38 `:-4:69 - 0 0 •.-:.:. 0 ..:._:. . . 485 485 ._. 1955 2275 F 22A tpl 0.989 22.45 0.00 63 9 202 ,-'0 0 318 45 1010 0 6 c)AED excursion -3 -24 Envelope loss/gain 635 447 4080 3850 12 a) Infiltration 104 36 521 178 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 739 483 4601 4029 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 739 483 4601 4029 15 Duct loads 10% 0% 0 0 0% 0% 0 0 Total room load 739 483 4601 4029 Air required (cfm) 28 23 176 193 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -_t� _FW wright90ft- 2015-Mar-06 08:43:11 Right -Suite® Universal 2013 13.0.01 RSU08101 Page 5 ..ocuments\Wrightsoft HVAC\WILLIAMS RESIDENCE.rup Calc = MJ8 Front Door faces: N -- wrightsoft, Right-J® Worksheet Entire House QUICK CALCS, INC. 317 ST. LUCIE LN., FORT PIERCE, FL 34946 Phone: 7724666799 Fax: 7724666796 Email: QUICKCALCS ,AOL.COM Job: Date: Sep 19, 2014 By: 1 Room name KITCHEN DINING ROOM 2 Exposed wall 21.0 ft 27.2 ft 3 Room height 10.7 ft heat/cool 10.7 ft heat/cool 4 5 Room dimensions Room area 12.0 x 144.0 ft' 12.0 ft 1.0 x 102.0 ftz 102.0 ft Ty Construction U-value Or HTM Area (ft2) Load Area (ft') Load number (Btuh/ft� °F) (Btu ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-40c6� 1Aclom .0143 1 270 W, n-' 3:25 28.83 �2.7� 2D:37 -40 0 -`21 0 69 0- S8 0 56 0 46 0 .:. � 149 A -3 125 0 1A-cloni • - , - '- 1.270 _`n �28.83 - - 20.37 _ -: . 0 0 0 0 0 0 -- 0 0. 1A.clom'� `;1.270 0.390 :n. ;;rig �°, r =28,83 � 885._ ' ; 5 20.37 ,11.78 0 �>A'9 . ; �' 0 �19 0 ", .166 ..-='-,220 0 :` '. 10 0 0 '' 0 -' 288 -. " 204' V11 U}! �G W 13A-4ocs 1A-clom 13A flocs= 1A c1om� ,.. _.. _ ..... 13A-4ocs 0.143 1.270, 0143 ._� _.. 1.270 0.143 ne ne e,- ` e: se 3.25 28.83 3.2 28.83 3.25 2.72 30.32 . 31:120, 4 2.72 0 0 0 0 0 0 0 v, .. 0 0 :,. 0 0 0 0 . _ 0 0 29 15 ��5 29 14 0 ,. 5 ,'.� 16 46 - 420 °4320 50 , 39 442 7 42 I--,G 4+/ ��Gp 1A-clom 13A flocs 1A c1om 1Ac1om: 1A-clom< 11D0 .' .'. 13A40cs 1A-clom �_. 1.270 ;Q143 �n1.270 1.270 ; 1.270 _ -0.390..9`Si35 0.143 1.270 se s;a ' . s.�< s s sw sw 28.83 ',325 28.83 28.83 28,83 3.25 28.83 22.94 .2.72 ,35.03, 20.37 20:37<: 11i78 2.72 20.95 0 96 G 0 D °= -a,0 0 0 , 0 '90 6 �° 0- �:.. 0 -_::'. 0 0 0 0 �291 180 - 0 ` ; , '- 0 SW.O _ 0 0 0 244 219 0- • ° 0 :^ 0 0 0 ` ' -` ' °'; 13 S6 0 0 11 0 0 0 10 45 -+ 0 -' 0-• , ' 11 . 0 0 0 384 147. 0 0= 312 �d.� 0 0 0 306 __ 123 e-0 =0 : 221 e , =0 0 0 C 11DO .--,, .. 16A-30md 0.390 _.m0.143 0.032 sw ` _w' 8.85 _ 3,25 0.73 11.78 _._ . 2.72 2.36 0 32 0 0 : _2 0 .. _ 0 .,104 . 0 0 . m.:, _87 1 -.:., .'-z 0.... 0:. 1 0 :. 1 _,., . 0 .0 0 .... ...: 0. 1 ... 2.38 _ _- 4:89 219 -.- 219 . ...- :622 - .; .=,1029 ': ,155 .:�:. ..1. ' .155 i. 369' - 126 F 22A-tpl 0.989 22.45 0.00 144 21 471 0 102 27 610 0 6 c)AED excursion 11 -17 Envelope loss/gain 1804 1846 3317 2768 12 a) Infiltration 243 83 315 108 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 2047 1929 3632 1 2876 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2047 1929 3632 2876 15 Duct loads 1 0% 0% 0 0 0% 0% 0 0 Total room load 2047 1929 3632 2876 Air required (cfm) 78 92 139 138 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. A wreghtsotrt 08 Right-SuiteO Universal 2013 13.0.01 RSU08101 2015-Mar-06 P'age16 ...ocuments\Wrightsoft WAC\WILLIAMS RESIDENCE.rup Calc = MJ8 Front Door faces: N This document was created with Win2PDF available at http://www.win2pdf.com. The unregistered version of Win2PDF is for evaluation or non-commercial use only. This page will not be added after purchasing Win2PDF.