HomeMy WebLinkAboutEPL Display CardENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 80
The lower the EnergyPerformance Index, the more efficient the home.
327 HOLIDAY OUT, JENSEN BEACH, FL,
- 1. New construction or existing
New (From Plans) 9. Wall Types
Insulation
Area
2. Single family or multiple family
Single-family a. Concrete Block - Int Insul, Exterior
R=4.1
1472.00 ft?
b. Frame -Wood, Adjacent
R=11.0
168.00 iE
3. Number of units, if multiple family
1 c. N/A
R=
ft=
4. Number of Bedrooms
2 d. N/A
R=
it,
5. Is this a worst case?
10. Ceiling Types
No
Insulation
Area
a. Under Attic (Vented)
R=30.0
1689.00 fi=
6. Conditioned floor area (1`12)
1689 b. N/A
R=
fN
7. VNmdows•* Description
Area c. NIA
R=
ft2
a. U-Factor: Sgt, U=0.49
201.33 ftz 11. Ducts
a. Sup: Attic, Ret: Attic, AH: Attic
R fP
6 201
SHGC: SHGC=0.32
b. U-Factor: WA
ft,
SHGC:
12. Cooling systems
kBtulhr
Efficiency
c. U-Factor. WA
fN a. Central Unit
35.0 SEER:16.00
SHGC:
d. U-Factor: NIA
fF
SHGC:
13. Heating systems
kBtulhr
Efficiency
Area Weighted Average Overhang Depth:
a. Electric Strip Heat
2.980 ft.
27.0
COP:1.00
Area Weighted Average SHGC:
0.320
8. Floor Types
Insulation Area 14. Hot water systems
a. Slab -On -Grade Edge Insulation
R=0.0 1689.00 ft' a. Electric
Cap:
40 gallons
b. N/A
R= ft'
EF: 0.92
c. N/A
R= fN b. Conservation features
None
15. Credits
Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed,
based on installed Cod mpli nt feat s.
Buil er��Signa use: oZ
Add es of New o e: WA
- Cit 7F, L ip:
_%,0, STg7�0
Z_'_
�� r wca-'w
'Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's
support staff.
`Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software
FORM 405-10
Florida Code Compliance Checklist
Florida Department of Business and Professional Regulations
Residential Whole Building Performance Method
ADDRESS: 327 HOLIDAY OUT PERMIT #:
JENSEN BEACH, FL,
MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details.
COMPONENT
SECTION
SUMMARY OF REQUIREMENT(S)
CHECK
Air leakage
402.4
To be caulked, gasketed, weatherstripped or otherwise sealed.
Recessed lighting IC -rated as meeting ASTM E 283. Windows and
doors = 0.30 cfm/sq.ft. Testing or visual inspection required.
Fireplaces: gasketed doors & outdoor combustion air. Must complete
envelope leakage report or visually verify Table 402.4.2.
Thermostat &
403.1
At least one thermostat shall be provided for each separate heating
controls
and cooling system. Where forced -air furnace is primary system,
programmable thermostat is required. Heat pumps with supplemental
electric heat must prevent supplemental heat when compressor can
meet the load.
Ducts
403.2.2
All ducts, air handlers, filter boxes and building cavities which form the
primary air containment passageways for air distribution systems shall
be considered ducts or plenum chambers, shall be constructed and
sealed in accordance with Section 503.2.7.2 of this code.
403.3.3
Building framing cavities shall not be used as supply ducts.
Water heaters
403.4
Heat trap required for vertical pipe risers. Comply with efficiencies
in Table 403.4.3.2. Provide switch or clearly marked circuit breaker
(electric) or shutoff (gas). Circulating system pipes insulated to =
R-2 + accessible manual OFF switch.
Mechanical
403.5
Homes designed to operate at positive pressure or with mechanical
ventilation
ventilation systems shall not exceed the minimum ASHRAE 62 level.
No make-up air from attics, crawlspaces, garages or outdoors adjacent
to pools or spas.
Swimming Pools
403.9
Pool pumps and pool pump motors with a total horsepower (HP) of =1
& Spas
HP shall have the capability of operating at two or more speeds. Spas
and heated pools must have vapor -retardant covers or a liquid cover or
other means proven to reduce heat loss except if 70% of heat from
site -recovered energy. Off/timer switch required. Gas heaters minimum
thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters
minimum COP= 4.0.
Cooling/heating
403.6
Sizing. calculation performed & attached. Minimum efficiencies per
Tables 503.2.3. Equipment efficiency verification required. Special
equipment
occasion cooling or heating capacity requires separate system or
variable capacity system. Electric heat >1OkW must be divided into two
or more stages.
Ceilings/knee walls
405.2.1
R-19 space permitting.
7/31/201410:36 AM EnergyGauge® USA - RaRes2010 Section 405.4.1 Compliant Software Page 5 of 5
COOLING SYSTEM
# System Type
Subtype
Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit
None
SEER:16
35 kBbft 1050 cfm
0.75
1
sys#1
HOT WATER SYSTEM
#
System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1
Electric
None
Garage
0.92 40 gal
50 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert #
Company Name
System Model # Collector Model
Collector
# Area
Storage
Volume
FEF
None
None
ftZ
DUCTS
/
V #
— Supply —
Location R Value Area
— Return —
Location Area Leakage Type
Air
Handler
CFM 25 CFM25
TOT
HVAC #
OUT
QN
RLF
Heat Cool
1
Attic
6 201 ft2
Attic
20 1`12 Default Leakage
Attic
(Default) (Default)
1 1
TEMPERATURES
amable Thermostat: Y
F.2..;g
Ceiling Fans:
Coolinenj ] Jan
eng 4X]) Jan
Venting Jan
Feb
Feb
H Feb
j j Mar
l(x1J Mar
[ ]
[IX]l
f [
Apr E
MMayay rl J [X]JulX
May Jun [ ] Jul
Aug
Aug
Sep
11 Sep �?C�
Oct
Oct
Nov
Dec
HDec
.
tl
Nov
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4 5 6
7
8
9
10
11
12
Cooling (WD)
AM
PM
78
80
78
80
78
78
78 78 78
78 78
78
78 80
80
80
80
Cooling (WEH)
AM
78
78
78
78
78 78 78
78
78 78
78
78
78
PM
78
78
78
78 78 78
78
70
78 78
70 78
78
78
78
78
78
78
Heating(WD)
AM
PM
66
68
66
68
66
68
66 66 68
68 68
68
68 68
68
68
68
Heating (WEH)
AM
66
66
66
68
66 66 68
68
68
68 68
68
66
66
nw�PM
68
68
68
68 68 68
68
68 68
68 68
68
68
66
66
7/31/201410:36 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software
Page 4 of 5
WALLS
A
Omt
djacent
ATo--
Wall Two
Space
Candy
Height
Sheathing Framing
Solar Below
1
N
Exterior
Concrete Block - Int Instil
Main
4.09999 40
8
320.0 ftz
0
2
E
Exterior
Concrete Block - Int Insul
Main
4.09999 52
8
416.0 ft2
0.75
0
3
S
Exterior
Concrete Block - Int Insul
Main
4.09999 40
8
320.0 ft'
0
0.75
0
4
W
Exterior
Concrete Block - Int Insul
Main
4.09999 52
8
416.0 *1
0
0.75
0
5
N
Garage
Frame - Wood
Main
11 21
8
168.0 ftz
0
0.75
0
0
0.75
0
DOORS
#
Omt
Door Type
Space
Storms
U-Value
Width Height
Area
Ft
In Ft In
1
S
Insulated
Main
None
.46
3
6 8
20 ft'
WINDOWS
Orientation shown is the entered, Proposed
orientation.
Wall
v #
Omt
ID
Frame
Panes
NFRC
U-Factor SHGC
Area
Depth Separation
Int Shade
Screenii
1
N
1
Metal
Single (Tinted)
Yes
0.49
0.32
16.0 ft'
6 It 0 in
6 It 0 in
Drapes/blinds
None
2
N
1
Metal
Single (Tinted)
Yes
0.49
0.32
33.3 ftz
6 ft 0 in
6 8 0 in
Drapes/Winds
None
3
E
2
Metal
Single (Tinted)
Yes
0.49
0.32
6.0 ft'
2 ft0 in
6 ft 0 in
Drapes/blinds
None
4
E
2
Metal
Single (Tnted)
Yes
0.49
0.32
16.0 ft'
2 It 0 in
6 It 0 In
Drapes/blinds
None
5
E
2
Metal
Single (Tinted)
Yes
0.49
0.32
12.01?
2 ft 0 in
6 ft 0 in
Drapes/blinds
None
6
S
3
Metal
Single (Tinted)
Yes
0.49
0.32
45.0 ft2
2 it 0 in
6 ft 0 in
Drapes/blinds
None
7
W
4
Metal
Single (Tinted)
Yes
0.49
0.32
40.0 1`12
2 ft 0 in
6 It 0 in
Drapes/blinds
None
8
W
4
Metal
Single (Tinted)
Yes
0.49
0.32
18.0 ftz
2 ft 0 in
6 It 0 in
Drapes/blinds
None
9
W
4
Metal
Single (Tinted)
Yes
0.49
0.32
15.0 IF
2 ft 0 in
6 It 0 in
Drapes/blinds
None
GARAGE
#
1
Floor Area
247 ft=
Ceiling Area
247 fI2
Exposed Wall Perimeter Avg. Wall Heig
21 It 8 ft
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH
1 Wholehouse
Best Guess
.0005
2215.1 121.61 228.7 .4247
HEATING SYSTEM
# System Type Subty
1 Electric Strip Heat None
COP: 1 27 kBtu/hr
Wall Insulation
11
ACH 50
9.8363
Block Ducts
1 sys#1
7/31/201410:36 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software
Page 3 of 5
PROJECT
f
Title: SULLIVAN RESIDENCE Bedrooms: 2
Building Type: User
Conditioned Area: 1689
Address Type:
Street Address
OwnerLot
Total Stories: 2
#
# of Units: 1
Worst Case: No
Block/SubDivision:
Builder Name:
Rotate Angle: 0
PlatBook:
-
Permit Office:
Cross Ventilation: No
Street:
327 HOLIDAY OUT
Jurisdiction:
Whole House Fan: Yes
County:
MARTIN COUNTY
Family Type: Single-family
City, State, Zip:
JENSEN BEACH,
New/E)dsting: New (From Plans)
FL,
Comment
CLIMATE
Design Location
IECC Design Temp Int Design Temp Heating.
TMY Site Zone
Design Dairy Temp
97.5 % 2.5 % 'Winter
Summer Degree Days Moisture Range
FL, West Palm Beach FL WEST PALM_BEAC 2 44 90
70
75 316
60 Medium
BLOCKS
Number Name
Area Volume
1 Blockl
1689 13512
SPACES
Number Name
Area Volume Kitchen Occupants Bedrooms
InfiIID Finished Cooled Heated
1 Main
1689 13512 Yes 4 2
1
Yes
Yes Yes
FLOORS
# Floor Type
Space Perimeter R-Value Area
1 Slab -On -Grade Edge Insulatio Main 198 It
Tile Wood Carpet
0 1689 ft'
�
0 0 1
ROOF
# Type
Roof Gable Roof Solar
Materials Area Area
SA Emitt
Emitt Deck Pitch
Color Absor.
Tested Tested Insul. (deg)
1 Hip
Metal 1829 ft2 0 ft2 Medium 0.96
No 0.9
No 0
22.6
ATTIC
` /
v # Type
Ventilation Vent Ratio (1 in) Area
RBS IRCC
1 Full attic
Vented 300 1689 fe
N N
CEILING1.
# Ceiling Type
Space R-Value Area
Framing Frac
Thus Type
1 Under Attic (Vented)
Main 30 1689 Rz
0.11
Wood
7/31201410:36 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software
Page 2 of 5
Y �
FORM 405-10
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name:
SULLIVAN RESIDENCE
Builder Name:
Street:
327 HOLIDAY OUT
Permit Office:
City, State, Zip:
JENSEN BEACH, FL,
Permit Number.
Owner:
Design Location:
FL, West Palm Beach
Jurisdiction:
1. New construction or existing
New (From Plans)
9. Wall Types � (11640.0 sqft.)
Insulation Area
2. Single family or multiple family
Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1472.00 ft2
3. Number of units, if multiple family
1
b. Frame - Wood, Adjacent
R=11.0 168.00 ft?
4. Number of Bedrooms
2
c. WA
d. NIA
R= ft2
5. Is this a worst case?
No
10. Cetrng Types (1689.0 sgft.)
R= ft2
Insulation Area
6. Conditioned floor area above grade ft�
9 (
1689
a. Under Attic (Vented)
R=30.0 1689.00 ftz
Conditioned Boor area below grade (tt2)
0
b. N/A
c. N/A
R= fN
R=
7. Windows(201.3 sgft.) Description
Area
11. Ducts
ft2
R ftz
a. U-Factor: Sgl, U=0.49
201.33 ft=
a. Sup: Attic, Ret: Attic, AH: Attic
6 201
SHGC: SHGC=0.32
b. U-Factor. NIA
SHGC:
fP
12. Cooling systems
kBtu/hr Efficiency
c. U-Factor: WA
a. Central Unit
35.0 SEER:16.00
SHGC:
fF
d. U-Factor. N/A
fF
13. Heating systems
kBtu/hr Efficiency,
SHGC:
a. Electric Strip Heat
27.0 COP:1.00
Area Weighted Average Overhang Depth:
2.980 ft.
Area Weighted Average SHGC:
0.320
14. Hot water systems
8. Floor Types (1689.0 sgft.)
Insulation Area
a. Electric
Cap: 40 gallons
a. Slab -On -Grade Edge Insulation
b. NIA
R=0.0 1689.00.ft2
b. Conservation features
EF: 0.920
c. N/A
_
R= �
None
15. Credits
Pstat
Glass/Floor Area: 0.119
Total Proposed Modred Loads: 36.78
Total Standard Reference Loads: 45.79
PASS
I hereby certify that the plans and specifications covered by
this calculation are in compliance with the Florida Energy
Review of the plans and
-HE S�
Code.
specifications covered by this
calculation indicates compliance
PREPARED Y:
with the Florida Energy Code.
DATE:
Before construction is completed
this building will be inspected for
a C
compliance with Section 553.908
o
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
r
with the Florida Ener Code.
tiCOD WE
OWN ` AGEIL�: 1
DA
BUILDING OFFICIAL:
DATE:
7131/201410:36 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software
Page 1 of 5