HomeMy WebLinkAboutEPL Display CardENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 80 The lower the EnergyPerformance Index, the more efficient the home. 327 HOLIDAY OUT, JENSEN BEACH, FL, - 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1472.00 ft? b. Frame -Wood, Adjacent R=11.0 168.00 iE 3. Number of units, if multiple family 1 c. N/A R= ft= 4. Number of Bedrooms 2 d. N/A R= it, 5. Is this a worst case? 10. Ceiling Types No Insulation Area a. Under Attic (Vented) R=30.0 1689.00 fi= 6. Conditioned floor area (1`12) 1689 b. N/A R= fN 7. VNmdows•* Description Area c. NIA R= ft2 a. U-Factor: Sgt, U=0.49 201.33 ftz 11. Ducts a. Sup: Attic, Ret: Attic, AH: Attic R fP 6 201 SHGC: SHGC=0.32 b. U-Factor: WA ft, SHGC: 12. Cooling systems kBtulhr Efficiency c. U-Factor. WA fN a. Central Unit 35.0 SEER:16.00 SHGC: d. U-Factor: NIA fF SHGC: 13. Heating systems kBtulhr Efficiency Area Weighted Average Overhang Depth: a. Electric Strip Heat 2.980 ft. 27.0 COP:1.00 Area Weighted Average SHGC: 0.320 8. Floor Types Insulation Area 14. Hot water systems a. Slab -On -Grade Edge Insulation R=0.0 1689.00 ft' a. Electric Cap: 40 gallons b. N/A R= ft' EF: 0.92 c. N/A R= fN b. Conservation features None 15. Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed, based on installed Cod mpli nt feat s. Buil er��Signa use: oZ Add es of New o e: WA - Cit 7F, L ip: _%,0, STg7�0 Z_'_ �� r wca-'w 'Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. `Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: 327 HOLIDAY OUT PERMIT #: JENSEN BEACH, FL, MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC -rated as meeting ASTM E 283. Windows and doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: gasketed doors & outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat & 403.1 At least one thermostat shall be provided for each separate heating controls and cooling system. Where forced -air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff (gas). Circulating system pipes insulated to = R-2 + accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower (HP) of =1 & Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor -retardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from site -recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters minimum COP= 4.0. Cooling/heating 403.6 Sizing. calculation performed & attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special equipment occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat >1OkW must be divided into two or more stages. Ceilings/knee walls 405.2.1 R-19 space permitting. 7/31/201410:36 AM EnergyGauge® USA - RaRes2010 Section 405.4.1 Compliant Software Page 5 of 5 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit None SEER:16 35 kBbft 1050 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.92 40 gal 50 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name System Model # Collector Model Collector # Area Storage Volume FEF None None ftZ DUCTS / V # — Supply — Location R Value Area — Return — Location Area Leakage Type Air Handler CFM 25 CFM25 TOT HVAC # OUT QN RLF Heat Cool 1 Attic 6 201 ft2 Attic 20 1`12 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES amable Thermostat: Y F.2..;g Ceiling Fans: Coolinenj ] Jan eng 4X]) Jan Venting Jan Feb Feb H Feb j j Mar l(x1J Mar [ ] [IX]l f [ Apr E MMayay rl J [X]JulX May Jun [ ] Jul Aug Aug Sep 11 Sep �?C� Oct Oct Nov Dec HDec . tl Nov Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM PM 78 80 78 80 78 78 78 78 78 78 78 78 78 80 80 80 80 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 70 78 78 70 78 78 78 78 78 78 78 Heating(WD) AM PM 66 68 66 68 66 68 66 66 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 66 66 66 68 66 66 68 68 68 68 68 68 66 66 nw�PM 68 68 68 68 68 68 68 68 68 68 68 68 68 66 66 7/31/201410:36 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 5 WALLS A Omt djacent ATo-- Wall Two Space Candy Height Sheathing Framing Solar Below 1 N Exterior Concrete Block - Int Instil Main 4.09999 40 8 320.0 ftz 0 2 E Exterior Concrete Block - Int Insul Main 4.09999 52 8 416.0 ft2 0.75 0 3 S Exterior Concrete Block - Int Insul Main 4.09999 40 8 320.0 ft' 0 0.75 0 4 W Exterior Concrete Block - Int Insul Main 4.09999 52 8 416.0 *1 0 0.75 0 5 N Garage Frame - Wood Main 11 21 8 168.0 ftz 0 0.75 0 0 0.75 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S Insulated Main None .46 3 6 8 20 ft' WINDOWS Orientation shown is the entered, Proposed orientation. Wall v # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screenii 1 N 1 Metal Single (Tinted) Yes 0.49 0.32 16.0 ft' 6 It 0 in 6 It 0 in Drapes/blinds None 2 N 1 Metal Single (Tinted) Yes 0.49 0.32 33.3 ftz 6 ft 0 in 6 8 0 in Drapes/Winds None 3 E 2 Metal Single (Tinted) Yes 0.49 0.32 6.0 ft' 2 ft0 in 6 ft 0 in Drapes/blinds None 4 E 2 Metal Single (Tnted) Yes 0.49 0.32 16.0 ft' 2 It 0 in 6 It 0 In Drapes/blinds None 5 E 2 Metal Single (Tinted) Yes 0.49 0.32 12.01? 2 ft 0 in 6 ft 0 in Drapes/blinds None 6 S 3 Metal Single (Tinted) Yes 0.49 0.32 45.0 ft2 2 it 0 in 6 ft 0 in Drapes/blinds None 7 W 4 Metal Single (Tinted) Yes 0.49 0.32 40.0 1`12 2 ft 0 in 6 It 0 in Drapes/blinds None 8 W 4 Metal Single (Tinted) Yes 0.49 0.32 18.0 ftz 2 ft 0 in 6 It 0 in Drapes/blinds None 9 W 4 Metal Single (Tinted) Yes 0.49 0.32 15.0 IF 2 ft 0 in 6 It 0 in Drapes/blinds None GARAGE # 1 Floor Area 247 ft= Ceiling Area 247 fI2 Exposed Wall Perimeter Avg. Wall Heig 21 It 8 ft INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH 1 Wholehouse Best Guess .0005 2215.1 121.61 228.7 .4247 HEATING SYSTEM # System Type Subty 1 Electric Strip Heat None COP: 1 27 kBtu/hr Wall Insulation 11 ACH 50 9.8363 Block Ducts 1 sys#1 7/31/201410:36 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 5 PROJECT f Title: SULLIVAN RESIDENCE Bedrooms: 2 Building Type: User Conditioned Area: 1689 Address Type: Street Address OwnerLot Total Stories: 2 # # of Units: 1 Worst Case: No Block/SubDivision: Builder Name: Rotate Angle: 0 PlatBook: - Permit Office: Cross Ventilation: No Street: 327 HOLIDAY OUT Jurisdiction: Whole House Fan: Yes County: MARTIN COUNTY Family Type: Single-family City, State, Zip: JENSEN BEACH, New/E)dsting: New (From Plans) FL, Comment CLIMATE Design Location IECC Design Temp Int Design Temp Heating. TMY Site Zone Design Dairy Temp 97.5 % 2.5 % 'Winter Summer Degree Days Moisture Range FL, West Palm Beach FL WEST PALM_BEAC 2 44 90 70 75 316 60 Medium BLOCKS Number Name Area Volume 1 Blockl 1689 13512 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfiIID Finished Cooled Heated 1 Main 1689 13512 Yes 4 2 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area 1 Slab -On -Grade Edge Insulatio Main 198 It Tile Wood Carpet 0 1689 ft' � 0 0 1 ROOF # Type Roof Gable Roof Solar Materials Area Area SA Emitt Emitt Deck Pitch Color Absor. Tested Tested Insul. (deg) 1 Hip Metal 1829 ft2 0 ft2 Medium 0.96 No 0.9 No 0 22.6 ATTIC ` / v # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1689 fe N N CEILING1. # Ceiling Type Space R-Value Area Framing Frac Thus Type 1 Under Attic (Vented) Main 30 1689 Rz 0.11 Wood 7/31201410:36 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 5 Y � FORM 405-10 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: SULLIVAN RESIDENCE Builder Name: Street: 327 HOLIDAY OUT Permit Office: City, State, Zip: JENSEN BEACH, FL, Permit Number. Owner: Design Location: FL, West Palm Beach Jurisdiction: 1. New construction or existing New (From Plans) 9. Wall Types � (11640.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1472.00 ft2 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=11.0 168.00 ft? 4. Number of Bedrooms 2 c. WA d. NIA R= ft2 5. Is this a worst case? No 10. Cetrng Types (1689.0 sgft.) R= ft2 Insulation Area 6. Conditioned floor area above grade ft� 9 ( 1689 a. Under Attic (Vented) R=30.0 1689.00 ftz Conditioned Boor area below grade (tt2) 0 b. N/A c. N/A R= fN R= 7. Windows(201.3 sgft.) Description Area 11. Ducts ft2 R ftz a. U-Factor: Sgl, U=0.49 201.33 ft= a. Sup: Attic, Ret: Attic, AH: Attic 6 201 SHGC: SHGC=0.32 b. U-Factor. NIA SHGC: fP 12. Cooling systems kBtu/hr Efficiency c. U-Factor: WA a. Central Unit 35.0 SEER:16.00 SHGC: fF d. U-Factor. N/A fF 13. Heating systems kBtu/hr Efficiency, SHGC: a. Electric Strip Heat 27.0 COP:1.00 Area Weighted Average Overhang Depth: 2.980 ft. Area Weighted Average SHGC: 0.320 14. Hot water systems 8. Floor Types (1689.0 sgft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation b. NIA R=0.0 1689.00.ft2 b. Conservation features EF: 0.920 c. N/A _ R= � None 15. Credits Pstat Glass/Floor Area: 0.119 Total Proposed Modred Loads: 36.78 Total Standard Reference Loads: 45.79 PASS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Review of the plans and -HE S� Code. specifications covered by this calculation indicates compliance PREPARED Y: with the Florida Energy Code. DATE: Before construction is completed this building will be inspected for a C compliance with Section 553.908 o I hereby certify that this building, as designed, is in compliance Florida Statutes. r with the Florida Ener Code. tiCOD WE OWN ` AGEIL�: 1 DA BUILDING OFFICIAL: DATE: 7131/201410:36 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 5