HomeMy WebLinkAboutRevision 12-17-15OFFICE USE ONLY:
DATE FILED: I a' 17• %J
REVISION FEE: _mac- 0 —
PERMIT # 7
RECEIPT # l l
PLANNING & DEVELOPIV
BUILDING & CODE REGUI
2300 VIRGINIA A
FORT PIERCE, FL
(772) 462-1553 FAX (
APPLICATION FOR BU
PROJECT
1. LOCATION/SITE
ADDRESS: �P 5� A)-vrueg-S 6 W�
a7� sL*3 '*'S mac-(-} EL— -3,Le c 5-1
2. DETAILED DESCRIPTION OF PROJECT
REVISIONS:
3.
4.
❑9
CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #: _
BUSINESS NAME: _
QUALIFIERS NAME: _
ADDRESS:
CITY:
PHONE (DAYTIME):
OWNER/BUILDER INFORMATION:
NAME:
ADDRESS:
CITY:
PHONE:
ST. LUCIE COUNTY CERT. #:
STATE:
FAX:
is STATE: ��
FAX:
5. ARCHITECT/ENGINEER INFORMATION:
NAME: L _ xto c L, A4 14
ADDRESS:
CITY: r-r, STATE:
PHONE (DAYTIME): `?
Revised 07/22/2014
ZIP:
ZIP:
ZIP:
FAX:
R °COVED
DEC 1' 7 2015
Lance Vogl Architect
201 SE Hibiscus Ave
Stuart, FL 34996
772-284-5327 lancevogi@yahoo.com
0
December 16, 2015
' St. Lucie County Building Department
2300 Virginia Ave
Ft. Pierce, FL 34982
Re: 1510-0009- Field Change Revision
Snyder Residence
515 Nettles Blvd
Jensen Beach, FL 34957
Dear Sir or Madam,
Please note the following regarding the above referenced project:
Field Change Revisions:
-The Fiber Cement Siding Product Approval has been changed. With this, the sheathing thickness has
been changed as well. See Sheet A1- Building Department Product Approval, sheet A3 - Sheathing
Nailing Schedule, sheet A5 - Building Section & sheet A6 - Typ. Wall Section.
Thank You,
Lance A. Vogl
Architect Reg. #96414
1� ` 1510 9
-* sove:2 O&TIoxAce - Se'�C- l06e' /g
PROJECT RIO-2553-15
ENGINEERING EVALUATION REPORT FOR ATTACHING JAMES HARDIE@) BRAND
FIBER -CEMENT PLANKS TO WOOD OR METAL FRAMED WALLS WITH VARIOUS FASTENERS
JAMES-HARDIE BUILDING PRODUCTS, INC.
10901 ELM AVENUE
FONTANA, CA 92337
TABLE OF CONTENTS
PAGE
COVER PAGE
1
EVALUATION SUBJECT
2
EVALUATION SCOPE
2
EVALUATION PURPOSE
2
REFERENCE REPORTS
2
TEST RESULTS
3
TABLE 1A and 1B, RESULTS OF TRANSVERSE LOAD TESTING
3-4
SUMMARY OF FASENTER DESIGN LOAD CALCULATIONS
5-6
TABLE 2A THROUGH TABLE 20, ALLOWABLE DESIGN LOADS BY PLANK WIDTH
7-11
DESIGN WIND LOAD PROCEDURES
12
TABLE 3, COEFFICIENTS AND CONSTANTS USED. IN DETERMINING V AND p
12
TABLE 4, ALLOWABLE STRESS DESIGN C&C PRESSURES EXPOSURE B
13
TABLE 5, ALLOWABLE STRESS DESIGN C&C PRESSURES EXPOSURE C
13
TABLE 6, ALLOWABLE STRESS DESIGN C&C PRESSURES EXPOSURE D
13
TABLE 7, ALLOWABLE WIND SPEED (MPH) FOR HARDIEPLANK SIDING
14-57
LIMITATIONS OF USE
57
AS PRODUCT EVALUATOR, THE UNDERSIGNED CERTIFIES THAT THE LISTED PRODUCTS ARE IN
COMPLIANCE WITH THE REQUIREMENTS OF THE ASCE 7 -10, THE 2014 FLORIDA BUILDING CODE,
AND THE 2012 INTERNATIONAL BUILDING CODE.
PREPARED BY:
RONALD 1.OGAWA & ASSOCIATES, INC.
16835 ALGONQUIN STREET #443
HUNTINGTON BEACH, CA 92649
714-292-2602
714-847-4595 FAX
v
RONALD 1. OGAWA ASSOCIATES, ZINC.
16835 ALGONQUIN STREET #443
HUNTINGTON BEACH, CA 92649
714-292-2602
714-847-4595 FAX
PROJECT: RIO-2553-15
JAMES HARDIE BUILDING PRODUCTS, INC.
1-888-542-7343
info@jameshardie.com
EVALUATION SUBJECT
HardiePlank® Lap Siding
James Hardie Product Trade Names covered in this evaluation:
HardiePlank® Lap Siding, CemPlank® Siding, Prevalw Lap Siding
EVALUATION SCOPE:
ASCE 7-10
2014 Florida Building Code
2012 International Building Code®
EVALUATION PURPOSE:
This analysis is to determine the maximum design 3-second gust wind speed to be resisted by an assembly of HardiePlank (CemPiank. Prevail Lap) siding fastened to wood or metal framing with
nails or screws.
REFERENCE REPORTS:
1. Intertek Report 3067913 (ASTM C1186) Material properties HardePlank Siding
2. Ramtech Laboratories, Inc. Report 10593-9611395 (ASTM E330) Transverse Load Test, 5/16' Thick by 7.5 inch wide HardiePlank Lap Siding installed on•2X4 W-Firwood studs space at 16
inches on center with a 0.093 inch shank by 0.222 inch head diameter by 2.5 inch long galvanized siding nail
3. Ramtech Laboratories, Inc. Report IC-1034-M (ASTM E330) Transverse Load Test, 5/16" Thick by 9.5 inch wide HardiePlank Lap Siding installed on 2X4 Hem -Fir wood studs space at 16
inches on.center with a Number 11 gauge 1-3/4 inch long galvanized roofing roil
4. Ramtech Laboratories, Inc. Report IC-1020-88 (ASTM E330) Transverse Load Test, 5/16" Thick by 9.5 inch wide HardePlank Lap Siding installed on 2X4 Hern-Fr wood studs space at 16
inches on center with a Bd common nail
S. Ramtech Laboratories, Inc. Report 2149-07-10 (C) (ASTM E330) Transverse Load Test, 5/16' Thick by 8.25 inch wide HardiePlank Lap Siding installed on 2X4 Doug-Fir4arch wood studs
space at 16 inches on center with an 8d ring shank box nail, 0.113 inch shank by 0.260 inch head diameter by 2.375 inch long
6. Ramtech Laboratories, Inc. Report 2149-07-10 (E) (ASTM E330) Transverse toad Test, 5/16' Thick by 8.25 inch wide HardiePlank lap Siding installed on 2X4 Doug -Fir -Larch wood studs
space at 16 inches on center with a 0.092 inch shank by 0.222 inch head diameter by 2.5 inch long galvanized siding nail
7. Ramtech Laboratories, Inc-Report2341-0"S (ASTM E330) Transverse Load Test, 5116" Thick by 8.25 inch wide HardePlank Lap Siding installed an 2X4 Doug -Fr -Larch wood studs space
at 16 inches on center with a 0,092 inch shank by 0222 inch head diameter by 2 inch long galvanized siding nail.
8. Ramtech Laboratories, Im Report 2149-07-10 (F) (ASTM E330) Transverse Load Test, 5/16' Thick by 8.25 inch wide HardePlank Lao Siding installed on 2X4 Spruce -Pine -Fur wood studs
space at 16 inches on cerderwith a 0.092 inch shank by 0.222 inch head diameter by 2.5 inch long galvanized siding nail
9. Ramtech Laboratories, Inc. Report 11149/1554 (ASTM E330) Transverse Load Test 5/16" TWA by 6.25 inch wide HardiePlank Lap Siding installed on 20 gauge metal studs spaced at 16 and
24 inches an center with ET&F knurled pin fastener
10. Ramtech Laboratories, Inc. Report 11149/1554B (ASTM E330) Transverse Load Test 5116' Thick by 825 inch wide HardiePlank Lap Siding installed on 20 gauge metal studs spaced at 16
and 24 inches on center with ET&F knurled pin fastener
11. Ramtech Laboratories, Inc. Report 1114911554A (ASTM E330) Transverse Load Test 511 6"Thick byl2 inch wide HardlePlank tap Siding installed on 20 gauge metal studs spaced at 16 and
24 inches on center with ETBF knurled pin fastener
12. Ramtech Laboratories, Inc. Report IC-1035-88 (ASTM E330) Transverse Load'Test 5/16" Thick by.9.5 inch HardiePlank Lap Siding installed on 20ga Metal Stud Spaced 16 Inches an Center
With No. 8 X 1-114" long X 0.375"head diameter ribbed wafer head screws
2412�-
RONALD 1. OGAWA ASSOCIATES, INC.
16835 ALGONQUIN STREET #443
HUNTINGTON BEACH; CA 92649
714-292-2602
714-847-4595 FAX
PROJECT: RIO-2553-15
JAMES HARDIE BUILDING PRODUCTS, INC.
1-888-542-7343
info@jameshardie.com
TEST RESULTS:
Table 1A. Results of Transverse load Testing for Configurations with Steel Framing
Report Number
11149
11149
11149
11149
11149
11149
IC-1035-88
/1554
11554
/1554B
11554E
11554A
11554A
Test Agency
Ramtech
Ramtech
Ramtech
Ramtech
Ramtech
Ramtech
Ramtech
Thickness (in.)
0.3125
0.3125
0.3125
'0.3125
0.3125
0.3125
0.3125
Width (in.)
6.25
6.25
8.25
8.25
12
12
9.5
20 ga. steel
20 ga.
20 ga.
20 ga.
20 ga.
20 9a•
20 ga. steel
Frame Type
studs
steel studs
steel
steel studsstuds
steel
steel
studs
studs
studs
Frame Spacing (m.)
16
24
16
24
16
24
16
ET&F
ET&F
ET&F
ET&F
ET&F
No. 8.X 1-
.10 0.100'
0.100'
0.100"
0:100"
0.100"
0.100'
1/4" long X
kmtded
knurled
knurled
knurled
knurled
knurled
0.375"
Fastener Type
shank
shank
sttank
shank
shank
shank
head
diameter x
diameter x
diameter
diameter x
diameter
diameter
diameter
0250' HD
0250' HD
x 0.313'
0.313" HD
x 0.250'
x 0.250'
ribbed
x 1.5' long
x 1.5' long
HD x 1.5'
x 1.5" long
HD x 1.5"
HD x 1.5"
waler head
long
long
long
screw
Fastening Method
Face nail
Face nail
Blind nail
Blind nail
Face nail
Face nail
Blind nail
Ultimate Load (psf)
317
173
64
50
151
81
1692
Design Load (psf)
105.7
57.7
21.3
19.7
50.3
27.0
56.4
Effective TnbularyArea (sqft)
0.556
0.833
0.778
1.167
1.194
1.792
0.917
Fastener Load, as tested
58.7
48.1
16.6
19.4
60.1
48A
51.7
(lb/fastener)
1. Allowable Design Load is the Ultimate Load divided Dy a t•actor or sate ry or J.
2. HardieShingle Siding complies with ASTM C1186, Standard Specificadan for Grade It, Type A No"shestos Fiber -Cement Flat Sheets.
;� tat` �n �}� �. r�A n � it•
FFi� r�
RONALD 1.OGAWA ASSOCIATES, INC.
16835 ALGONQUIN STREET #443
HUNTINGTON BEACH; CA 92649
714-292-2602
714-847-4595 FAX
PROJECT: RIO-2553-15
JAMES HARDIE BUILDING PRODUCTS, INC.
1-888-542-7343
info@jameshardie.com
Table 1B. Results of Transverse Load Testing for Configurations with Wood Framing
Report Number
10593-
IC-1034.88
IC-1020-
2149-07
2149-07-
2341-M
2149-07-10
96/1395
88
10(C)
10(E)
06
(F)
Test Agency
Ramtech
Ramtech
Ramtech
Ramtech
Ramtech
Ramtech
Ramtech
Thickness (in.)
0.3125
0.3125
0.3125
0.3125
0.3125
03125
0.3125
Width (in.)
7.5
9.5
9.5
8.25
8.25
8.25
8.25
Frame Type
2X4 wood
2X4 wood
2X4 wood
2X4 wood
2X4 wood
2X4 wood
2X4 wood
Hem -Fir
Hem -Fir
Hem -Fir
DFL
DFL
DFL
SPF
Frame Spacing (tn.)
16
16
16
16
16
16
16
8d siding
1-314'
8d ring
8d siding
8d siding
8d siil'tng
nail. 0.093"
No. 11 ga.
6d
shank box
nag,
nail,
nail, 0.092'
Fastener Type
X 0.222° X
Roofing
common
nail, 0.113'
0.092" X
0.092" X
X 0.222" X
2.5"
nail
nail
X 0.260" X
0222" X
0.222X
25"
2.375'
2.5"
2'
Fastener Length (in.)
2.5
1.75
2
2.375
25
2
2.5
Fastening Method
Blind nag
Blind nag
Face nag
Face nag
Face nail
Face nag
Face nail
Ultimate Load (psf)
92
146.6
199
296
253
165
168
Design Load (psf)
30.7
48.9
66.3
98.7
84.3
55.0
56.0
Effective Tributary Area (sgff)
0.694
0.917
0.917
0378
0.778
0.778
0.778
Fastener Load. as tested
21.3
44.8
60.6
76.7
65.6
42.8
43.6
(lb/fastener)
Adjusted withdrawal design load
54.6
46.2
41.6
84.0
67.0
49.1
43.0
(lb/fastener), W
Net Fastener Penetration (in,), P
2.18B
1.438
1.375
1.750
1.875
1.375
1.875
Wood Speck Gravity, G
0.43
0.43
0.43
0.50
0.50
0.50
0.42
Nail Shank Diameter (in.), D
0.093
0.120
0.113
0.113
0.092
0.092
0.092
Withdrawal design value per NDS
2012 or ESR-1539 (lblin. penetration),
15.6
20.1
18.9
30.0
22.3
22.3
14.3
W
Catculated fastener withdrawal toad is compared with the test result
and the more conservative one will be used.
1. Allowable Design Load is the Ultimate Load divided by a Factor of safety of 3.
2. HardieShingle Siding complies with ASTM C1166, Standard Specificaftton for Grade 11, Type A Nbn-asbestos Fiber -Cement Flat Sheets.
3. Calculated fastener withdrawal load is bompared with the testresult and the more conservative one vrig be used.
For all cases in the table, the adjusted withdrawal design value, W', is calculated as
W =Co'W"P
Where,
Co = Iced duration factor per NDS-2012 Table 2.32 for wind/earthquake load =1.6
W = withdrawal design value, calculated per NDS-2012,or ESR-1539, whichever applicable
P = fastener embedment depth, in.
When nail shank, D,'a 0.099 Inch but 5 0.375 inch for smooth shank nabs, NDS-2012 equation (11.2-3) is used to calculate withdrawal design value
W = 1380' Gtwt' D
Where,
G = wood specific gravity per Table 11.3.3A
D = nail shank diameter, in.
When nail shank, D, is less than 0.099 inch, or in the case of ring shank nags, the withdrawal design values were obtained from ICC-ES ESR-1539Table 2.
ILE
RONALD 1. OGAWA ASSOCIATES, %INC'.
16835 ALGONQUIN.STREET #443
HUNTINGTON BEACH, CA 92649
714-292-2602
714-847-4595 FAX
PROJECT: RIO-2553-15
JAMES HARDIE BUILDING PRODUCTS, INC.
1-888-542-7343
info@jameshardie.com
Summary based on Report 10593-9611395 (2.5 in. Iona by 0.093 in. shank by 0.222 in. head diameter) sidino nails blind nailed into wood studs):
Nail withdrawal design load was determined to be 15.6 Ibfin. penetration„based:on ESR-1539 Table 2, for 0.093" smooth shank nail. With 0.43 wood specific gravity.
The adjusted fastener withdrawal design value W' = Ce' W ' P=1.6'15.6'2.188 = 54.6 lb.
The tested design fastener load with a factor of safety 3 applied is 21.3 pounds per fastener, which is less than the adjusted fastener withdrawal design value of 54.6 pounds, so to be
conservative, the tested fastener load of 21.3 pounds will be used for the calculation -
Calculation for 6d siding nail (2 in. long by 0.093 In. shank by0.222 in. head diameter) blind nailed Into wood studs:
Using the same timber, but changing the nail length to a 6d siding nail (2 in, long by 0.093 in. shank by 0.222 in, head diameter) yields an adjusted fastener withdrawal design value of
42.0 pounds per fastener
Nail withdrawal design value, VIf = 15.61hlnpenetration;
Net Penetration for a 2" nail through 5/16' fiber cement, P = 1.688":
W = Co • W ' P = 1.6'15.3'1.688 =420 mlfastener).
Based on the rationale below, a 6d siding nail can be directly substituted for the 8d siding nail:
))The mode of failure for the 2.5 inch long by. 0.093 inch shank by 0.222 inch head diameter siding nails is fastener head pull through the fiber -cement, the head diameter controls the
failure, the 6d and 8d.siding nail have the same head diameter (0.222°), and
2) The adjusted fastener withdrawal design value for the 2 inch long by 0.093 inch shank by 0.222 inch head diameter siding nag is 42lb/fastener, this exceeds the test fastener design
load of 21.31bslfastener.
For the two reasons above, the 6d siding nail blind nailed can directly substitute the 8d siding nait of the same shank and head diameters. 'Results in Table 2F are used to calailate
allowable basic wind speed for the 6d siding nail (2 inch long by 0.093 inch shank by 0.222 inch head diameter) blind nalled into wood studs.
Summary based on. Report iC-1034-88 (No.11cla 1.75" Iona roofing nail blind nailed into wood studsl:
The adjusted fastener withdrawal design value, W, is calculated per NDS-2012•
Specific gravity, G=0.43,.
Nail shank diameter, D=0.120';
Nail penetration depth for 1.75" nail installed on 5116" fiber cement plank, P=1.4381;
Calculated withdrawal design value, W=1380' Gt5rn' D=1380'0.43r5.0.120 = 20.1 Ibfin penetration;
Adjusted withdrawal design value, VW = Cc' W ' P=1.6"20.1'1.438 = 46:2lb.
The tested design fastener load with a facto of safety 3 applied is 44.8 pounds per fastener, Ktich is less than the NDS adjusted fastener withdrawal design value of 46.2 pounds.
Hence for calculation of allowable basic wind speed, tested fastener load of 44.8 pounds for a No. 11 gauge 1.75 inch long roofing nail will be used.
In Table 2G below, the fastener bad is held constant at 44.81bs/fastener for each plank width, the allowable sing design toed is back calculated from the tested fastener design load.
Siding design load is equal to fastener design load divided by fastener tributary. Results In Table 2G are used to calculate allowable basic wind speed for the Number 11 gauge 1.75 inch
long roofing nail.
Calculation for No. 11 ga.1.2W long roofing nail blind nailed into wood studs:
Report IG1034-88 (1.75' lore 11 ga. roofing nail) yielded a tested fastener load of 44.79 [Wastener with the failure mode being fastener head pug through the fiber -cement. Therefore
we know that the fiber -cement fastened blind nailed with a roofing nail is limited to 44.79 lb/fastener. Using the same timber as specified in Report IC-1034-88, but charging the nail
length to a 1.25 inches long yields an adjusted fastener withdrawal design value of 30.1 pounds.per fastener.
Calculated withdrawal design value, W = 20.1 lb/in, penetration;
Nail penetration depth for 1.25' nail installed over 5/16" fiber:cemenfplank. P = 0.938';
Adjusted withdrawal design value, VP = Co' W ' P=1.6'20.1'0.938 = 30.1 Ibffastener.
In this case, the adjusted witbdrwal design value is the control factor, since ifs less than the tested design fastener load. Siding design load is equal to fastener design load of 30.1
lb/fastener divided by fastener tributary. See Table 2H below, for the calcuated siding design loads for each {lank width. Results in Table 2H are used to calculate allowable wind speed
for the Number 11 gauge 1.25 inch long roofing nag used in a blind nail appfuation
R +'iit �i
RONALD I. OGAWA ASSOCIATES, INC.
16835 ALGONQUIN STREET #443
HUNTINGTON BEACH, CA 92649
714-292-2602
714-847-4595 FAX
PROJECT: RIO-2553-15
JAMES HARDIE BUILDING PRODUCTS, INC.
1-888-542-7343
info@jameshardie.com
Summary based on Report 1020-88 f6d common nail face nailed Into wood studs):
The adjusted fastener withdrawal design value based on NDS-2012 is 41.6 pounds per fastener. The tested design fastener load with a factor of safety 3 applied is 60.8 pounds per
fastener. The NDS adjusted fastener withdrawal design value of 41.6 pounds is more conservative when compared against the tested fastener bad. Hence for calculation of aikiwable
basic wind speed, the siding design bad for a 6d common nail face nailed will be calculated based on fie NDS-2012 adjusted fastener withdrawal design value 41.6 Ibs/fastener. See
Table 21below for the calculated sift design bads for each plank width using a 6d common. Results in Table 21 are used to calculate allowable basic wind speed for the 6d common
nail, face nailed.
Calculation for 8d common nail face nailed into wood studs:•
We would Ike to use the ultimate test values obtained in report 1020-88. to dothis we propose substituting an 8d common nail for the tested 6d common nail Doing this substituffan
resolves the disparity between the NDS and tested. values on fasteners. Below are the rationale for substituting the 8d common for the 6d common nail used in testing report 1020-88 to
achieve the stated ultimate test load of 199 psf, a design bad of 66.3 psp.
1) Use the same timber as in the report, bid change the nag to a larger 8d common, nail (2.5" long x 0.131' shank diameter x 0.281' head diameter);
2) The 8d common yields an NDS adjusted fastener withdrawal design value of 65.8 pounds per fastener
Specific gravity, G=0.43; Shank diameter, D =0.131"; Net Penetration for a 2.5" nail through two layers of 5116' fiber cement=.1.875";
Withdrawal design value, W =1380' Gtsm " D = 21.9 Iblin penetration;
Adjusted withdrawal design value, W = Co:W'P =1.6' 21.9 "1.875 = 65.8' lb.
3) The mode of failure for the 6d common nail (report 1020-88) is fastener withdrawal from timber. Since the 8d common nail has a larger bearing area under the fastener head than
the 6d common, we can anticipate at least the'same fastener pull through capacity from an 8d common nail:
6d common head bearing area (head diameter = 0266 inches, shank diameter 0.113 inches) = 0.0455 sq inches;
8d common tread bearing area (head diameter = 0.281 inches, "shank diameter 0.131 inches) = 0.0485 sq'inches;
4) The.NDS adjusted fastener withdrawal design value for the Idd common Is 65.8 lb/fastener, this exceeds the tested fastener design load of 60.81bs/fastener (for a 6d common in
report 1020-88), therefore we can use the ultimate failure pressure of 199 psf to tabulate a design pressure 66.3 psf with an 8d common nail (60.8 lbsffastener), this will be used to
calculate wind design.
For the 4 reasons above, the 8d common can be directly substituted for the 6d common used in report 1020-88. See Table 2J for the calculated siding design bads for each prank width.
Results in Table 2J are used to calculate allowable basic wind speed for the 8d common nail face nailed into wood studs.
Summary based on Report 2149-07-10(C) (8d ring shank box nail face nailed into wood studs):
Nail withdrawal design bad was determined to be 30 Ibfm. penetration, based on ESR4539 Table 2, for 0.113' deformed shank nail with 0.50 wood specific gravity.
Nail penetration depth for 2.37W long nail through two layers of 5H6' fiber cement planks, P = 1.75";
The adjusted fastener withdrawal design value W = Co • W • P=1.6.30`1.75 = 84.0 lb.
The tested design fastener load with a factor of safety 3 applied is 76.7 pounds.per fastener, which Is less than the adjusted fastener witdrawal design value of 84 pounds. Hence for
calculation of allowable basic wind speed, tested fastener load of 76.7 pounds will be used.
In Table 2K below, the fastener bad is held constant at 76.7 Ibs/fastener for each plank width. the allowable -siding design load is back calculated from the tested fastener design load.
Siding design load is equal to fastener design'load divided by fastener tributary. Results in Table 2K are used to calculate allowable basic wind speed for 8d ring shank box nail face
nailed into woad studs.
ti iM V.
� �ti• a ,• �t .,all �j.i: uF
i:•
r {t
RONAL.D I. OGAWA ASSOCIATES, INC.
16835 ALGONQUIN STREET #443
HUNTINGTON BEACH, CA 92649
714-292-2602
714-847-4595 FAX
PROJECT: RIO-2553-15
JAMES HARDIE BUILDING PRODUCTS, INC.
1-888-542-7343
info@jameshardie.com
For Table 2A to 2N the designs loads will be calculated by proportioning the tributary area to each fastener, thereby design load to each fastener will be kept constant. By doing so, the allowable
design load for various HardiePlank widths and stud spacing will be determined.
Table 2A, Allowable Design Loads Based on Constant Fastener Load, ET&F 0.100" knurled shank x 0.25V HD x 1.5" long, 16" OC 20ga Metal Studs, fasteners exposed (face nail)
Check for results using 625 inch plank values from Report Number 11149/1554 and 11149/1554A.
Design load = ultimate failure load/FOS =-317psf/3 = -105.7 psf
Effective tributary = ((plank width exposed to weather X stud spacingu144) = ((6.25.1.25) X 16)/144 = 0.556 sq.ft.
Fastener load = design load X tributary area=-105.67 X 0.558 = -58.7 pounds
Calculated allowable design load = fastener load tested condition divided by area tributary for the condition to be calculated
m
a
0
O
ai+
Q
m T
O
W
0
0
U)
�JO
a
HardiePlank Width
E
m
(inches)
ci 5
in -`
w i`-
¢ p a
LL
5.25
16
0.4444
-132.08
-58.70
6.25
-317
16
0.5556
405.67
-58.70
7.25
16
0.6667
-88.06
58.70
7.5.
16
0.6944
-84.53
58.70
8
16
0.7500
-78.27
-58.70
0.25
16
0.7778
-75A8
-58.70
9.25
16
0.8889
-66.04
-58.70
9.5
16
0.9167
-64.04
. -58.70
12
-151
16
1.1944
50.33
-60.12
Table 2B, Allowable Design Loads Based an Constant Fastener Load, Ei&F 0.1W' knurled shank x 0.250" NO x 1.5" long, 24" OC 20ga Metal Studs, fasteners exposed (face nail)
Check for results using 6.25 inch plank values from Report Number 11149/1554 and I I149/1554A.
Design bad = ultimate faffure1oadIFOS=173psf/3 = 57.67 psf
Effective tributary= ((plank width exposed to weather X stud spacaig)/144) = ((6.25-1.25) X 24u144 = 0.6333 sq.fL
Fastener load = design load X tributary area = 57.67 X 0.8333 = 48.06 pounds
Calculated allowable design load = fastener load tested condition divided by area tributary for the condition to be calculated
N
G
m
9
C.d.
O
Q
m D
m^
d
_
HardiePlank Width
2
(inches)
rm 5
rn
`w ` N
- o a
LL J
5.25
24
0.6667
72.08
-48.06
6.25
-173
24
0.8333
-57.67
48.06
7.25
24
1.0000
-48.06
A8.06
7.5
24
1.0417
-46.13
48.06
8
24
1.1250
-42.72
-48.06
8.25
24
1.1667
41.19
48.06
9.25
24
1.3333
-36.04
A8.06
9.5
24
1.3750
-34.95
-48.06
12
-81
1 24
1 1.7917
-27.00
1 48.38
Table 2C, Allowable Design Loads Based on Constant Fastener Load, ETBF 0.100" knurled shank x 0.313" HD x 1.5" long, 16" OC 20ga Metal Studs, fasteners concealed (blind nail)
Check for results using 825 Inch plank values from Report Number 111491`1554B.
Design load = ultimate failure k>adIFOS =-64psf/3= 721.33 psf
Effective tributary = ((plank width exposed to weather X stud spacing)/144) = ((8.25-1.25) X 16j/144 = 0.778 sq.1L
Fastener load = design load X,tdbuta_ry area ,= 21.33X 0.778 = -16.59 pounds
Calculated allowable design load = fastener load tested condition divided by area tributary for the condition to be calculated
c
•Om
m
o
C
A
®.0.1
0 .1 _
Is
C
Ha diePlank Width
_E
y O
O
rn
N
(niches)
4- op7
N..
!u it:'s
Q Q IL
0
IL J
5.25
16
0.4444
-37.33
-16.59
6.25
16
0.5556
-29.87
-16.59
7.25
16
1 0.6667
-24.89
1 -16.59
7.5
16
0.6944
-23.89
-16.59
8
16
0.7500
-22.12
-16.59
8.25
-64
16
0.M8
-21.33
-16.59
9.25
16
0.8889
-18.67
-16M
9.5
16
0.9167
-18.10
-16.59
12
16
1.1944
-13.89
-16.59
RONALD 1. OGAWA ASSOCIATES, INC.
16835 ALGONQUIN STREET #443
HUNTINGTON BEACH, CA 92649
714-292-2602
714-847-4595 FAX
PROJECT: RIO-2553-15
JAMES HARDIE BUILDING PRODUCTS, INC.
1-888-542-7343
info@jameshardie.com
Table 2D, Allowable Design Loads Based on Constant Fastener Load, ET&F 0.100" knurled shank x 0.313" HD x 1.5" long, 24" OC 20ga Metal Studs, fasteners concealed (blind nail)
Check for results using 8.25 inch plank values from Report Number 1114911554B.
Design load = ultimate failure loadIFOS =-Mpsf/3 = -16.67 psf
Effective tributary = ((plank width exposed to weather X stud spacmg)1144) = ((8.25-1.25) X 24)/144=1.1667 sq.fL
Fastener load = design lead X tributary area=-16.67X 1.1667 = -19.44 pounds
Calculated aieviable design load = fastener lead tested condition divided by area tributary for the condition to be cacuiated
N
C
m
m
�
n
O lU
U
d y
CO N
Q
_> lc0
O
HardiePlank Width
H E
m
m =
3T
m u
m
(inches)
H 0 5
co
W F- N
- o a
IL -1
5.25
24
0.6667
-29.17
-19.44
6.25
24
0.8333
-23.33
-19.44
7.26
24
1.0000
-19.44
-19.44
7'.5
24
1.0417
-18.67
-19A4
8
24
1.1250
-17.28
-19.44
8.25
-50
24
1.1667
-16.67
-19.44
9.25
24
1.3333
-14.58
-19.44
9.5
24
1.3750
-14.14
-19.44
12
24
1.7917
-10.85
1 -19.44
Table 2E, Allowable Design Loads.Based on Constant Fastener Load, No. 8 X 1-5/8"•long X0.375" HD ribbed waferhead screw, 20ga. Metal Studs, fasteners concealed (blind nail)
Check for results using 9.5 inch plank values from Report Number IG-1035-88
Design load = ultimate failure load/FOS =-169.2psf/3 = -56.4 psf
Effective tributary = ((plank width exposed to weather X stud spacingu144) = ((9.5-1.25) X 16Y144 = 0.9167 sq.ft.
Fastener load = design load X tributary area = -56A X 0.9167 = -51.7 pounds
Calculated allowable design load = fastener load tested condition divided by area tributary for the condition to be calculated
a
U
Qco
till
50
HardiePlank Width
"-� c
v
6 a ci
LL
o 0
w in
inches
(inches)
m o =
u-o�
a)�
u,
ao�a
uf0a
5.25
16
0.4444
-116.33
51.70
6.25
16
0.5556
-93.06R�51;700
7.25
16
0.6667
77.55
7.5
16
0.6944
-74.45
8
16
0.7500
-68.93
8.25
16
0.7776
-66.47
9.25
16
0.8889
-58.16
9.5
-169.2
16
0.9167
-56.40
12
16
1.1944
- 3.28
�
c
�
m
U
N
m O
o
m a
o l
j
w
w
24
0.6667
-77.55
24
0.8333
-62.04
24
1.0009
-51.70
24
1.0417
-49.63
24
1.1250
45.96
24
1.1667
-44.31
24
1.3333
-38.78
24
1.3750
-37.60
24
1.7917
-28.86
Table 2F, Allowable Design Loads Based on Constant Fastener Load; 6d siding nail 2.0" L, W-Fir Studs, fasteners concealed (blind nail)
Check for.results using 7.5 inch plank values from Report Number10593-9611395: The following example will demonstrate the basic analysis:
Design load = ultimate failure load/FOS =-92psf/3 =-30.7psf
Effective tributary = ((plank width exposed to weather X stud spacing)/144) = ((7.5-1.25) X 16)1144 = 0.694 sq.fL
Fastener load = desgn load X tributary area = �30.7 X 0.694 =-21.3 pounds, which will be used for the calculation
Adjusted fastener withdrawal lead from NDS-2012 = 42.0 Wastener, which is larger than the tested fastener load
Calculated allowable design load = fastener load tested condition divided by area tributary for the condition to be calculated
mv�pp
C d
O
G
a-
Q
m
N O
J
N
N
v N
co m
a t0 .--
N -+
S.
.O
HardiePlank Width
y 2 E
v=
m n w
a
a
(IrICt1e5)
O U 7
W .�
W H W
Q 0 �'
LL J
5.25
16
0.4444
-47.92
-21.30
6.25
16
05556
-38.33
-21.30
7.25
16
1 0.6667
-31.94
-21.30
7.5
-92
16
0.6944
-30.67
-21.30
8
16
0.7500
-28.40
-21.30
8.25
16
0.7778
-27.38
-21.30
9.25
16
0.8889
-23.96
-21.30
9.5
16
0.9167
-2323
-21.30
12
16
1.1944
-17.83
1 -21.30
rn
C
W
O
¢
N
0 O
0
? N .�
R C
t=i
0
m .O
Wr=v
W `
QOa
24
0.6667
-31.94
24
0.8333
-25.56
24
1.0000
-21.30
24
1.0417
-20.44
24
1.1250
-18.93
24
1.1667
-18.25
24
1.3333
-15.97
24
1.3750
-15.49
24
1.7917
-11.89
\ \\\`\111i111tliilill/f777j77,' /
RONALD I. OGAWA ASSOCIATES, INC.
16835 ALGONQUIN STREET #443
HUNTINGTON BEACH, CA 92649
714-292-2602
714-847-4595 FAX
PROJECT: RIO-2553-15
JAMES HARDIE BUILDING PRODUCTS,INC.
1-888-542-7343
info@jameshardie.com
Table 213, Allowable Design Loads Based on Constant Fastener Load, No.11ga. Roofing nail "4" L, Hem -Fir Studs, fasteners concealed (blind nail)
Check for results using 9.5 inch plank values from Report Number IC-1034-88.
Design load = ultimate failure Ioad1FOS =-146.6ps03 = -08.9 psf
Effective tributary = ((plank width exposed to weather X stud spacuug)1144)=,((8.25-1.25) X 16)/144 = 0.9167 sq.fL
Fastener load = design load X tributary area = -48.9 X .9167 = -44.79 pounds, which will be used for the calculation
Adjusted fastener %-A txirawal load from NDS-2012=46.2lbffasterw, which is larger than the tested fastener load
Calculated allowable design load = fastener load tested condition divided by area tributary for the condition to be calculated
rn
m
N
C
m
v
V1
C
0.2
l0
Co
m
tD J
HardiePlank Width
- c
�•
m a' Q
o N
N m
w
rLLn
- a
(inches)
1- 0 5
m -`
i-= -a
ri .3
5.25
i6
0.4444
-100.79
-44.79
6.25
16
0.5556
-80.63
-44.79
7.25 1
16
0,6667
1 -67.19
-4419
7.5
16
0A944
-64.50
-44.79'
8
16
0.7500
-59.73
-44.79
8.25
16
0.7778
-57.59
-44.79
925
16
0.8889
-50.39
-44.79
9.5
446.6
16
0.9167
-48.87
-44.79
12
16
1.1944
-37.50
-44.79
�
m
a
C
U
¢
m O
0^
U 7 w
24
0.6667
-67.19
24
0.8333
-53.75
24
1 1,0000
-44.79
24
1.0417
-43.00
24
1.1250
-39.82
24
1.1667
-36.40
24
1.3333
-33.60
24
1.3750
3258
24
1.7917
-25.00
Table 21-1, Allowable Design Loads Based on Constant Fastener Load, No.11ga. Roofing nail 1-114" L, Hem -Fir Studs, fasteners concealed (blind nail)
The design load in this case is limited by both test result of report IC-1034-88 and. Adjusted withdrawal load from NDS-2012
Siding design load in this:case is equal to the adjusted fastener withdrawal design load 30.1 8i/fastener divided by fastener tributary area
�
c
a
U
d^
U >
C.'
�
O
HardiePlank Width
o m N
H m
(Inches)
c
V) c
o
W "I
m
;ito a
v m o
a LL a
5.25
16
0.4444
-67.73
-30.1
6.25
16
0:5556
-54.18
-30.1
7.25
16
0.6667
-45.15
-30.1
7.5
16
0.6944
-43.341-1.11
.1
8
16
0.7500
-40.138.25
16
0.7778
-38.700.19.25
16
0.8889
-33.860.19.5
16
0.9167
32-840.112
161.1944
-25.200.1
M
c
v
coO
m
m
r-
rzi N
C
m G C,
O m rn
LU
a.
24
0.6667
45.15
24
0.8333
-36.12
24
1 1.0000
-30.10.
24
1.0417
-28.90
24
1.1250
-26.76
24
1.1667
-25,80
24
1.3333
-2258
24
1.3750
-21.89
24
1.7917
46.80
Table 21, Allowable Design Loads Based on Constant Fastener Load, 6d common nail V L, Hem -Fr Studs, fasteners exposed (face nail)
Check for results using 9.5 inch plank values from Report Number IC-1020-88.
Design load = ultimate failure load/FOS =-199psf/3 = -66.3 psf
Effective tributary = ((plank width exposed to weather X stud spacing)/144) = ((9.5-1.25) X 16)/144 = 0.9167 sq.fL
Fastener load = design load X tributary area = -66.33 X 0.9167 = -60.81 pounds
Adjusted fastener withdrawal load from NDS-2012 = 41.6 lb/fasterter, in this case it's more conservative and will be used for the calculation
Calculated allowable design load = adjusted fawithdrawal load divide by area tributary for the condition to be calculated
rn
m
CL
U
¢
{v�QQ
O
O d
IO]. N.
j Z
.GJ
mL
HardiePlank Width
m c E
o
m a Q
o y u.
m m
(inches)
v
m
w i--S
- a a
LLO. J
5.25
16
0.4444
-93.60
-41.60
6.25
16
0.5556
-74.88
-41.60
7.25
16
0.6667
-62AO
-4140
7.5
16
0.6944
-59.90
-41.60
8
16
0.7500
-55.47
-41.60
825
16
0.7778
53.49
-11.60'
9.25
16
0.8889
-46.80
-41.60
9.5
-199
16
0.9167
-45.38
-41.60
12
1 16
1.1944
-34.83
-41.60
�
m
v
U
�
m p
m
?
C ^
j U
-1 m!
0�.�.
Oof
�U1
in zr_r
w
-aa
24
0.6667
-62.40
24
0.8333
-49.92
24
1.0000
41.60
24
1.0417
-39.94
24
1.1250
36.98
24
1.1667
-35.66
24
1.3333
-31.20
24
1.3750
30M
24
1.7917
-23.22
RONALD 1.OGAWA ASSOCIATES, INC..
16835 ALGONQUIN STREET #443
HUNTINGTON BEACH, CA 92649
714-292-2602
714-847-4595 FAX
PROJECT: RIO-2553-15
JAMES HARDIE BUILDING PRODUCTS, INC.
1-888-542-7343
info@jameshardie.com
Table 2J, Allowable Design Loads Based on Constant Fastener Load, 8d common nail 2.5" L, Hem -Fir Studs, fasteners exposed (face nail)
The design toad In this case is limited by both test result of report IC-1020-88 and Adjusted withdrawal load from NDS-2012
Siding design load in this case is equal to the adjusted fastener withdrawal design load (30.1 Iblfastener) divided by fastener tributary area.
Design load = ultimate failure badlFOS =-199psf/3 = -66.3 psf
Effective tributary = ((plank width exposed to weather X stud spacing)/144) = ((9.5-125) X 16)r144 = 0.9167 sq.fL
Fastener load = design load X tributary area = -66.33 X 0.9167 = -6021 pounds, which will be used for the ca$culation
Adjusted fastener withdrawal load from NDS-2012 =65.8 Iblfastener, which is larger than the tested fastener toad
Calculated allowable design load = fastener load tested condition divided by area tributary for the condition to be calculated
m
v
U
Q
p
J
m a
HardiePlank Width
o
v is
c
m o E
u)m
.>_w'�
w
.fl
`°c
o y LL
m„
m
(inches)
ai.
a- cr >
c
in
w F m
u)
a nn a.
a
5.25
16
0.4444
-136.82
-60.81
6.25
16
0.5556
-109A6
-60.81
7.25
16
0.6667
-91.22
-60.81
7.5
16
0.6944
-87.57
-60.81
8
16
0.7500
-81.08
-60.81
825
16
0:7778
-78.18
-60.81
9.25
16
0.8889
-68.41
-60.81
9.5
-199
16
0.9167
-66.33
-60.81
12
16
1.1944
-50.91
-60.81
m
U
Q
(aQ
p
MN
> 2 .-.
m
.. p C
o a Q
Wa=m
o m W
-.oa
a
NS
24
0.6667
-9122
24
0.8333
-72.97
24
1.0000
-60.81
24
1.0417
-68.38
24
1.1250
-54.05
24
1.1667
-5212
24
1.3333
-45.61
24
1.3750
-4422
24
1.7917
-33.94
Table 2K, Allowable Design Loads Based on Constant Fastener Load, 8d (2-318"L) ring shank box nail, DFL Studs, fasteners exposed (Mee nail)
Check for results using 8.25 inch plank values from Report Number 2149-07-10 (C).
Design load = ultimate failure k>ad1FOS =-296psf/3 = -98.7 psf
Effective tributary = ((plank width exposed to weather X stud spacl ng)I144) = ((825-1.25) X 16)/144 = 0.778 sq.ft
Fastener toad = design load X tributary area =-98.7 X 0:778 = -76.74 pounds, which will be used for the calculation
Adjusted.fastener withdrawal load per ESSR-1539 = 84 lbibstener, which is larger than the lest fastener bad
Calculated allowable design load = fastener load tested condition divided by area tributary for the condition to be calculated
Q
o
m
tnm
mrn
`ma
c
HardiePlank Width
y c_
"o t
U
m a cr
a LL
N
m M
(in
!�- U 7
.�.
V)
W F-
_o
Q a a
LL J
5.25
16
0.4444
-172.67
-76.74
6.25
16
0.5556
-138.13
-76.74
7.25
16
0.6667
-115.11
-76.74
7.5
16
0.6944
-110.51
-76.74
8
16
0.7500
-10232
-76.74
8.25
-296
16
0.7778
-98.67
-76.74
9.25
16
0.W89
-6.33
-76.74
9.5
16
0.9167
-83.72
-76.74
12
16
1AW
-64.25
-76.74
m
c
m
m �
cc
0
o
UJ
t
VAC
3 mLL
CO)
24
0.6667
-115.11
24
0.8333
-92.09
24
1.0000
-76.74
24
1.0417
-73.67
24
1.1250
-6B21
24
1.1667
-65.78
24
1.3333
-57.56
24
1.3750
-55.81
24
1.7917
42.83
Table 2L Allowable Design'Loads Based on Constant Fastener Load, Bd siding nail (0.092" shank), DFL Studs, fasteners exposed (face nail)
Check for results using 825 inch plank values from Report Number 2149-07-10 (E).
Design load = ultimate failure IoadIFOS =-253psU3 = 4W.3 psf
Effective tributary = ((plank width exposed to weather X stud spacurg)/144) = ((8.25-125) X 16v144 = 0.778 sq.fL
Fastener toad = design load X tributary area = -84.3 X 0.778 = -65.59 pounds, which will be used for the calculation
The adjusted nail withdrawal load per ESR-1539 = 67.0 lb/fastener, which is larger .than the test fastener toad.
Calculated allowable design load = fastener load tested condition divided by area tributary for the condition to be calculated
rn
n
U
m
Q
fv�pp
O
vs
HardiePlank Width
m c E
v
w a
o
.=
(inches)
m ci �
w -`
w r=
- a a
11 3
5.25
16
0.4444
-147.58
-65.59
6.25
16
0.5556
-118.07
-65.59
7.25
16
1 0.6667
-98.39
-65.59
7.5
16
0.6944
-94A5
-65.59
8
16
0.7500
-87.46
-65.59
8.25
-253
16
0.7778
-84.33
-6s.59
9.25
16
0.8889
-73.79
-65.59
9.5
16
0.9167
-71.56
_65.59
12
16
1.1944
-54.91
-65.59
C
m
�
�
U
Q
m O
m
J
C,
Q
c m W
rn
'u
- ❑ d
24
0.6667
-98.39
24
0.8333
-78.71
24
1.0000
-65.59
24
1.0417
-62.97
24
1.1250
-58.30
24
1.1667
-5622
24
1.3333
24
1.3750
24
1.7917
RONALD 1. OGAWA ASSOCIATES, INC.
16835 ALGONQUIN STREET #1443
HUNTINGTON.BEACH, CA 92649
714-292 2602
714-847-4595 FAX
PROJECT: RIO-2553-15
JAMES HARDIE BUILDING PRODUCTS, INC.
1-888-542-7343
info@jameshardie.com
Table 2M, Allowable Design Loads Based on Constant Fastener Load, 6d siding nail (0.092" shank), DFL Studs, fasteners exposed (face naiQ
Check for results using 8.25 inch plank values from Report Number 234.1-08-06.
Design load = ultimate failure kradlFOS =-165psfM = -55 psi
Effective tributary = ((plank width exposed to weather X stud spacing)1144) = ((8.25.1.25) X 16)/144 = 0.778 sq.ft.
Fastener load = design load X tributary area = -55.0 X 0.778 = -42.78 pounds. which win be used for the calculation
The adjusted wail withdrawal load per ESR-1539 = 49.1 lbffastener, which is larger than the test fastener load.
Calculated allowable design load = fastener load tested condition divided by area tributary for the condition to be calcLLWad
m
v
n
u
¢`
m B
HardiePlank Width
O m
tp
.'
N
(inches)
co
nLLm
-1
5'25
16
0.4444
-9625
-42.78
6.25
16
0:5556
-77.00
42.78
7.26
16
0.6667
-64.17
-4218
7.5
16,
0.6944.
-61.60
-42.78
8
16
01500
-57.04
42.78.
825
-165
16
0.7778
-55.00
-42.78
925
16
0.8889
-08.11
-42.78
9.5
16
.0-9167
-46.67
42.78
12
16
1.1944
-35.81
-42.78
rn
U
10
Q
(vp
B
m Z
m J
mac
LL
v)
24
0.6667
-64.17
24
0.8333
-51.33
24
1.0000
-42.78.
24
1.0417
-41.07
24
1.1250
-38.02
24
1.1667
36.67
24
1.3333
-3Y.08
24
1.3750
31.11
24
1.7917
-23.88
Table 2N, Allowable Design Loads Based on Constant Fastener Load, 8d siding nail (0.092" shank), SPF Studs, fasteners exposed (face nahQ
Check for results using 8.25 inch plank values from Report Number 2149-07A0 (F).
Design load = ultimate failure load/FOS =-168psff3 = -56.0 psf
Effective tributary = ((plank width exposed to weather X stud spacmg)/144) = ((8.25-1.25) X 16)1144 = 0.778 sq.fL
Fastener load = design load X tributary area = -56.0 X 0.778=-43.56 pounds
The adjusted nail wdhdrawal load per ESR-1539 = 43.0 Vlastener, which is more conservabe and will be.used for the calculation.
Calculated allowable design load = fastener toad tested condition dividedby area tributary for the condition to be calculated
m
G
CI
S
W
O
��Opp
Q
O
HardiePlank Width
co
m
(inches)
� ii �
ai c
US
inm
a 8,
a � -
5.25
16
0.4444
'-96.75
-43.00
6.25
16
0:5556
-77AO
-43:00
7.25
16
0.6667
-64.50
-43.00
7.5
16
0.6944
-61.92
43.00
8
16.
0.7500
-57.33
-43.00
8.25
-168
16
0.7778
-5S.29
43.00
9.25
16
0.6889
-48.38
43:00
9.5
16
0.9167
46.91
-43.00.
12
1 16
1.1944
-36.00
1 43.00
�
m
0
C
�
Q
m"
m O
J
rn m
> m -•-•
mn
N C
�=
&
Lu
m�
¢oa
24
0.6667
-64.50
24
0.8333
-51.60 7
24
1.0000
-43.00
24
1.D417
-41.28
24
.1A250
-3822
24
1.1667
-36.86
24
1.3333
-32.25
24
1.375D
-3127
24
1.7917
-24.00'
p �y-
sf
h
! D
RONALD 1. OGAWAASSOCWTES,tNC.
16835 ALGONQUIN STREET #443
HUNTINGTON BEACH, CA 92649
714-292-2602
714-847-4595 FAX
PROJECT: RIO-2553-15
JAMES HARDIE BUILDING PRODUCTS,-INC.
1-888-542 7343
info@jameshardie:com
ueaivle-wnw
1 e%An
Fiber -cement siding transverse load capacity (wind load capacity) Is determined via compliance testing to transverse load national teststandards. Via the transverse toad testing an
allowable design load is.determined based on a factor of safety of 3 applied to the ultimate test bad.
Since the allowable design toad is based our factor of safety of 3, allowable design bads on fiber: cemenlsiding correlate duectly to required design pressures for Allowable Stress
Design, and therefore should be used with combination.lgaduig equations for Allowable Stress Design (ASD). '
By using the combination loading equations for Allowable Stress Design (ASD), the tested allowable design loads for fiber -cement siding are aligned with the wind speed requirements in.
ASCE 7-10 Figure'26.5-1A, Figure 26.5-1B, and Figure 26.5-1 C.
For this analysis, to calculate the.pressures.ln Tables 4, 5, and 6, the load combination will be in accordance with ASCE 7-10 Section 2A combining nominal bads using allowable stress
design, load combination 7. Load combination 7 ruses a load factor of 0.6 applied to the wind velocity pressure.
Equation 1, q6=0.0025WK. K,t%C'VZ
% , velocity pressure at height z
K� , velocity pressure exposure coefficient evaluated at height z
K .,"topographic.factor
K, , wind directionality factor
V , basic wind
speed (3-
Equation 2,
V=V,e
V,m design wind
speeds(3-
Equation 3, p=cV(G"Cij
GCp , product of external pressure coefficient and gust -effect factor
GCp, , product of internal pressure coefficient and gust -effect factor
p ,.design pressure (PSF) for siding (allowable design load for siding)
To determine design pressure,'substitute q, Into Equation 3,
Equation 4, p=0.00256,j VK,r *V' 2*(GCp-GCp)
Allowable Stress Design, ASCE 7-10 Section 14,1, load combination 7,
(ref..ASCE 7-10 equation 30:3-1]
(ref. 2012 IBC & 2014 FBC Section 1602a definitions}
tref. ASCE 7-16 equation 36.6-1)
Equation 5, 0.613* 0.6W (ref.ASCE 7-10 section 2.4A, load combination 7)
D . dead load
W , wind load {toad due to wind pressure)
To determine. the. Allowable Stress Design Pressure, apply the load factor for (wind) from Equation 4 to p (design pressure) determined from equation 4
Equation 6, per= 0.6'[p]
Equation 7, p. = 0.6'10.00256*VK,1'Ka'V R •(GCp-GC. -)j
Equation 7 is used to populate Table 4, 5,.and 6.
To determine the allowable ultimate basic wind speed for Hardie Siding In Table 7, solve Equation 7 for V a,
Equation 8, V h = (pmt0.6'0.0026Vl`VK2 V(GCp-GC0)f 5
Applicable to methods spedfred in Exceptions 1 through "3 o112012 iBC, 2014 FBC] Section 1609.1.1., to determine the allowable nominal design wind speed (Vaso) for bards SkDN in
Table 7, apply the conversion formula below,
Equation 9, Vd = V,e' (0.6r fret: 20121BC & 2014 FBC Section 1609:3.1)
V. , Nominal;design wind speed (3-second gust mph) (ref. 2012IBC & 2014 FBC Section1616Z 1)
Table 3, Coefficients and Constants used in Determining V and p,
Kz
Wall zone
Height (ft)
Exp B
F� C
Exp D
Ka
Ka
G
G
0-15
0.7
0.85
1.03
115M
1
0.85
-1.4
0.18
20
0.7
0.9
1.08
1
0.85
-1.4
0.18
25
0.7
6.94
-Ti-2
1
0.85
-1.4
0.18
30
0.7
0.98
1.16
1
0.85
-1.4
0.18
35
0.73
1.01
1.19
1
.0.85
-1.4
0.18
40
0.76
1.04
1.22
1'1
0.85
-1.4
1 0.18
45
0.785
1.065
1.245
1
0.85
-1.4
0.18
50
0.81
1.09
1.27
1
0.85
-1.4
0.18
55
0.83
1.11
1.29
1
0.85
-1.4
0.18
60
0.85
1.13
1.31
1
0.85
-1.4
0.18
100
0.99
1.26
1.43
h>80
1"
0.85
-1.8
0.18
12
� .4F
I
I
N
00 ono
ii7
�ii�uio
a
��
m
s
V'
TON)
C
0
cnn(NnA
V NN
W
iO
W(J�O
i.WN
o m<o
m
bO
CliD
W
W-4
4V
-.
A
N Q)
M
:1
�1
N V
N
V C
C C
V
O
isLn1
7n
/-.
5 tii
S
m v
It
Nb)oia�ni7)intn
,)�
N iewyoNwrniar'rn
N �
O b 4)
.P N
6 A
C LJ
tD
C
(71
N
N+Of�OmlAN
W�
v
a
im
N 4)
4) N
il iio
W +l
in
O.
Gf
[O t0
0)N
Ol
{Np
V
-4�
�+tD
�On (rn
(OD�D
AOOf
A
in
-+V
A.
OD 6)-.
V
G
Al
O
b,
i0W V
1J V
is N
m i
A
�w�do
OD O)N
Nbp�N
,yovAN,O�DOo
c�fp710
N
OD
O
j
�w
A
NO
L4ipp0
0
�k
f0
C
A
-po� CQn
App
A d
V
A'
V
�1 a
N O
�0 {
to in
N t00
U�) O
in W11wWOWNiDNV
ID 1
_
0
=
m
0
O
G)
W (O
(J1 O
N CD
N .P
G1 Cn
W
Ot
N N
(n U)
N
A
NiN
N".+lOn8i0
N
N
V Nib
I
V O
W.P
N4f
two
m V
V 01
W N
A W
N -N+
CJ
A
IWV
NNN CN1
ON
b, cn
N INV
O
WV
L4()
n
-+
Lo G7
L4-�
A bf
Ll Of
b) K)
� N
c7D,
07
b)tD
V IV
�i
(O,�7a
1D OD
W r
(O�-WW+iO
NA.N
�cNo
0�i
A
b -.
44K.
N b
:N- b)
pG�
J44,
NA
A W
NO
CO
A
nA0
bo
V fC+s.Oa
Co
55O
G
A
,tea
W
`A
j fn
N
1+cn
:b.JW��
to cDU
bn
bf
G.c11
li)
,VIwtO
�0n�
0
0
A�pp
Obl)
b)V N
wp�o
b�nno 00
w
o VO
^+
AN
O b)O
h1AO
V L4
N
V A
)1
(7 pp
En
fn fJ0
N-V+t
O V
in fn
G(�J
N OD
OO)
N
N
V N
W O
W
o
y
��pp
V
N 47
.P N
0
0 tJ
V0
Cl�
W
ivb)iDwcba
icb)w
O
T
ON
iD
b) iD
N ini0Lj
m
S
7
a
O' 01
W
�+o
A g
cn�i+o
W
iD)io0
O
m
m
ODLn
74070
V
p0)As
N
A
A W
:P
G
co ,
07 OD
V V
� VI
Vt fn
O1 m
O
N
)D A
iD W
0) i0
i0 w
c0
W
r�4:—J:4
O N
1J
M 0
O)
cn (n
01
WW
NV
N�+OO7
(O
(O fD
xD 07�
io
L4
b)
'J ib
bx 6
6
f0
N�D N
W CD
N N
V O)
N N
N A
N N
A A
N
A W
(bI
6] b'
c0 IV
A Cn
A A
A .P
'.P
Cn
O
W �7
W N
j W
O
N N
0
PO
N N
N
N ab)V
V VNCFOW
W
W
v1
1WW
V
OD
NNN
'to to
fS� 6
iV wC))
N
O
fn
OO
O
cn
bD 41
UI :-1
tI
t1
O
�4nn1
N
ip
P
W
p A
b1 +
OO
GD
sm
P
O
co ODcol
OD
�t�p0
JN��
�co
;P.
O.Ln
b3
A
t7 V
V �1
V Q7
N V
V
V V
V
O
7. D
O
CPS a°DD m
denim
3 N =
N
D
w w O
aWm
m
C
3 6
Z
O
O
C
n
1
y
RONALD 1. OGAWA ASSOCIATES, INC.
16835 ALGONQUIN STREET #443
HUNTINGTON BEACH, CA 92649
714-292-2602
714-847-4595 FAX
PROJECT: RIO-2553-15
JAMES HARDIE BUILDING PRODUCTS, INC.
1-888-542-7343
info@jameshardie.com
Table 7, Allowable Wind Speed (mph) for HardiePlank Lap Siding(Analytical Method in ASCE 7-10 Chapter 30 C&C Part 1 and Part 3)e ``,``\`\`��`1Ut(o iGfq NAZI
� 4:=�4�S IFJC.,j* s9 z,
20121BC, 2014 FBC
2012IBC, 2014 FBC
;' V •tC'� y
Allowable, Ultimate
Design Wind, Speed,
V,o4,
Allowable, Nominal
Design Wind, Speed,
V. 5.5
_ 2412
= °%
(3-second gust mph)
(3-second gust mph)
9 , STATE
'• �C` •'
��i �� �Q R)p;;••�a ����
s.TR1ED(IEG�``���
Coefficients used in Table 6 calculations for V,a
Applicable to methods
specified In (2012IBC,
16097 as
01B
(2012 IBC, 2014 FBC)
Figures 1609A, B, or C.
Applicable to methods
}
��2014, ��ZB on
1609.1.1.
Wind exposure gory
Wind exposure categoryl
Siding
K,
Product
Product
Thickness
Width
Fastener
Type
Fastener
Spacing
Frame
Type
Stud
Spacing
(inches)
Building
Height'''
(feet)
B
C
D
B
C
D
Allowable
DesignLoad(inches)
Load
(PSF)
Exp B
Exp C
Exp 13
Ks
K.
GC,,
GCd
0-15
182
165
150
141
128
116
-47.9
0.7
0.85
1.03
h M
1
0.85
4A
0. 88
20
1 182
161
147
141
124
114
-47.9
0.7
09
1,08
1
0.85
-1.4
0.18
25
182
157
1"
141
122
112
-47.9
0.7
0.94
1.12
1
0.85
AA
0.18
HardiePlank
5116
5.25
0.093"
shank X
0.222" HD
X 2.0" long
galy. Siding
nail
Blind nail
2X4
wood W-
Fir
16
30
182
154
142
141
119
110
1 -4T9
0.7
0.98
1.16
1
0.85
-1.4
0.18
35
178
152
140
138
117
108
-47.9
0.73
1.01
1.19
1
0.85
-1.4
0.18
40
175
149
138
135
116
107
-47.9
0.76
1.04
122
1
0.85
-1.4
0.18
45
172
148
137
133
114
106
-47-9
0.785
1.065
1245
1
0.85
-1.4
0.18
50
169
146
135
131
113
105
-47.9
0.81
1.09
127
1
0.85
-lA
0-18
55
167
145
134
130
112
104
-47-9
083
1-11
129
1
085
-IA
0.18
60
165
143
133
128
111
103
47.9
0.85
1.13
1.31
1
0.85
-IA
0.18
100
1 137
121
114
106
94
88
-47.9
029
1.26
IA3
h>60
1
0.85
-1.8
0.18
0-15
163
148
134
126
114
104
-38.3
0.7
0.85
1.03
h560
1
0.85
-1.4
0.18
20
163
144
131
126
111
102
1 -38.3
0.7
0.9
1.08
1
0.85
-1.4
0.18
25
163
141
129
126
109
100
-38.3
0.7
0.94
1.12
1 10.851
-1.4
10.181
HardiePlank
5116
6.25
0.093'
shank D
shank X
X 2.0' long
galv. Siding
nail
Blind nail
2X4
wood W-
Fr
16
30
163
138
127
126
107
98
-38.3
0.7
0.98
1.16
1
0.85
-1A
0.18
35
159
136
125
124
105
97
-38.3
0.73
1.01
1.19
1
0.85
-1A
0.18
40
156
134
123
121
103
96
38.3
0.76
IA4
122
1
0.85
-1.4
0.18
45
154
132
122
119
102
95
-38.3
0.7a5
1.065
1245
1
8-5-
-lA
0.18
50
151
131
121
117
101
94
38.3
0.81
1.09
127
1
0.85
-1.4
0A8
55
150
129
120
116
100
93
-38.3
0.83
1.11
129
1
0.85
AA
0.18
60
148
128
119
114
99
1 92
1 -383
0.85
1.13
1.31
1
0.85
4.4
0.18
100
122
108
102
95
84
79
-38.3
0.99
126
1.43
h>60
1
0.85
-1.8
0.18
0-15
149
135
123
1 115
105
95
-31.9
0.7
1 0.85
1.03
tK60
1
0.85
44
0.18
20
149
131
120
115
102
93
-31.9
0.7
M9
1 1.08
1
0.85
-1A
0.18
25
14-57
128
118
#####g
99
91
31.9
0.7
0.94
1.12
1
0.85
-1.4
0.18
HardiePlank
5116
7.25
0.093"
shank
0.222" HD
X 2.0" long
gale. Siding
nail
Blind nail
2X4
wood W-
Fir
16.
30
57
126
116
44
97
69
-31.9
0.7
0.98
1.16
1
0.85
-1A
0.18
35
146
124
114
113
96
88
31.9
0.73
1.01
1.19
1
0.85
-1.4
0.18
40
143
122
113
111
95
87
31.9
0.76
1.04
122
1
0.85
-IA
0.18
45
140
121
112
109
93
86
31.9
0.785
1.065
1245
1
0.8 5
-1.4
0.18
119
110
107
92
86
31.9
081
1.09
i27
1
0.85
-1.4
0.18
137
118
110
106
91
85
-31.9
0.83
1-11
129
1
0.85
4.4
0.18135
r5O136
117
109
105
91
84
31.9
0.85
1.13
1.31
1
0.85
4 A
0.18112
99
93
87
77
72
-31:9
0.99
1.26
IA3
h>60
1
0.85
-1.8
0.18
0-15
146
132
120
113
102
93
30.7
0.7
0.85
1.03
h560
1
0.85
-IA
0.18
20
146
129
117
113
100
91
30.7
0.7
0.9'
1.08
1
0.85
-1.4
0.18
25
146
126
115
113
97
89
-30.7
0.7
0.94
1.12
1
0.05
-IA
0.18
HardiePlank
5116
7.5
0.093,
shank X
0:222• HD
X2.0' long
galy. Siding
nail
Blind nail
2X4
wood W-
Fr
16
30
146
123
113
113
95
88
30.7
0.7
om
1.16
1
085
4.4
0.18
35
143
121
112
111
94
87
30.7
0.73
1.01
L19
1
O85
4A
0-18
40
140
120
110
108
93
86
30.7
0.76
1.04
122
1
0.85
-1A
0.18
45
138
118
109
107
92
85
30.7
0.785
1.065
1245
1
0.85
-1.4
0.18
50
135
117
108
105
90
84
-30.7
0.81
1.09
127
1
0.85
-1.4
0.18
55
134
116
107
104
90
83
30.7
0:93
1.11
129
1
0.85
-1-4
0.18
60
132
115
107
102
89
-311 i
0.851
5. 13
E743T
1
5
W
0.18
100
109
97
91
0.99
41 _
?=143
f0ff
i 1
fig'
0.1E
0-15
140
127
116
0=
9'",
9(j V
21 4&,14 i
4 0?*
4iz-0
n03P
0'',
1a
0.18
'
20
140
124
113
1p9
M 6 ?'
8:
0 7t�"
�1, r
�M89'
'1(
oA8
HardiePlank
5116
8
0.093'
shank X
0.222" HD
X 2.0' long
galy. Siding
nail
Blind nail
2X4
wood W-
Fir
16
25
140
121
111
1 9
r
86
i'
10 •y
Q.94
a 7 ''
(oyr
1;
D.18
30
140
119
109
1 9'
2
A
o.
35
137
117
108
1 Chu`
P :00 ;'
4!8
!Q $
: 0. `
• 0
`.
1 $'
rri'.
0.18
40
135
115
106
1q4,
v , 9rt
*W
,, a
.76
l75
6.18
45
132
114
105
1 3.
8 '+
81
"= 4
70Y,
1.
-
N-'PC
0.19
50
55
130
129
112
111
104
103
10.4
1 tl
8
nn
`,•, 80;
a
.4
1n
lo.
D,1 '
C1 1"
ri27
K1
t"fr.
Ad
A
,
1''
0.18
0.18
60
127
110
103
9 ;' ,
85
*7$,
.4
a5
1
1
1
-rr
0.18
100
105
93
88
8Y
8
28.4
0.99
126
1.43
h>60
1
0.85
.1.8
0.18
14 LE,-,'--,C 0 PY
RONALD 1. OGAWA ASSOCIATES, INC.
16835 ALGONQUIN STREET #443
HUNTINGTON.BEACH, CA 92649
714-292-2602
714-847.4595 FAX
PROJECT: RIO-2553-15
JAMES HARDIE BUILDING PRODUCTS, INC.
1-888-542-7343
info@jameshardie.com
///
2012 IBC, 2014 FBC
2012IBC, 2014 FBC
2412
Allowable, Ultimate
Design Wind, Speed,
Allowable, Nominal
Design Wind, Speed,'
(3-second gust mph)
v
(3•second gust mph)
l STA E OF : Q
��i��/•••'.,LO,�{,;p
TFRED E G °•
II/1111 II1N
Coefficients used in Table 6 calculations for V.
Appiicable tamethods
specified 4FBC]�edion
1609.1.1. as determined by
[20121BC, 2014 FBC]
Figures 1609A, B. or C.
specified in Exceptiole to ns 1
through of 12012 IBC,
2014 FBCI Sectien
1609.1-1.
Wutd exposure cate'.ry
Wind exposure category
Siding
K(
Produrt
Product
Thickness
(inches)
Width
(inches)
Fastener
Type
Fastener
Spacing
Frame
Type
Stud
Spacing
(inches)
Building
Height''
(feet)
B
C
D
6
C
D
All°wab9e
Design
toad
(PSF)
ExpB
Exp C
FxpD
K.
Ka
I GCo
GCa
0-15
1 138
125
114
107
97
88
-27.4
0.7
0.85
1.03
hs60
1
0.85
-1.4
0.18
20
138
121
111
107
94
86
1 27.4
0.7
0.9
1.08
1
0.85
4A
0-18
25
138
119
109
107
92
84
-27,4
0.7
1 0.94
1.12
1
0.85
-1.4
0.18
HardlePlank
5I16
825
0.093'
shank
0.222" HD
X 2.0' long.
galy. Siding
nail
Blind nail
2X4
wood W-
Fir
16
30
138
1 116
107
107
90
83
27.4
0.7
0.98
1.16
1
0.85
-1A
0.18
35
135
115
106
104
89
82
-27.4
0.73
1.01
1.19
1
0.85
-1.4
0.18
40
132
113
104
102
88
81
-27.4
0.76
1.04
122
1
0.85
-1.4
0.18
45
130
112
103
101
86
80
-27.4
0.785
1.065
'1245
1
0.85
4.4
0.18
50
128
110
102
99
85
79
-27A
0.81
1.09
127
1
0.85
-1.4
0.18
55
126
109
101
98
85
79
-27.4
0.83
1.11
1.29
1
0.85
4.4
0.18
60
125
108
101
97
84
78
-27.4
0,85
1.13
1.31
1
0.85
-1.4
0.18
100
103
92
86
80
71
67
-27.4
0.99
1 126
1.43
h>60
1
0.85
-1.8
0.18
0-15
129
117
106
100
91
82
24A
0.7
0.85
1.03
tiSM
1
0-85
4A
0.88
20
129
1 114
104
100
88
80
24.0
0.7
0.9
1.08
1
0.85
4A
0.18
HardiePlank
5116
925
0.093"
shank X
0.222' HD
X 20' long
galvnail
nail
Blind nail
2X4
wood W-
Fir
16'
25
129
111
102
100
86
79
-24.o
0.7
0.94
1-12
1
0.85
-1.4
0.19
30
129
109
100
100
84
78.
24.0
0.7
.0.98
1-16
1
0.85
-1.4
0.18
35
126
107
99
98
83
77
-24.0
0.73
1.01
1.19
1
0.85
-1A
0-18
40
124
106
98
96
82
76
24.0
0.76
1.04
122
1
0.85
-tA
0.18
45
122
104
97
94
81
75
24-0
9.065
9245
1
0.85
-1.4
0.18
50
120
103
95
93
80
74
-24.0
1.09
127
9
085-1A
0.18
55
118
102
95
92
79
74
-24.0
1.11
129
1
0.85
-1A
0.18
60
117
101
94
91
79
73
-24.0
N0.7785
1.13
1.3
1:4
0.18
100
9786
81
75
66
62
-24.0
126
1.43
h>60
1
0.85
4.8
6.18
0-15
127
115•
105
98
89
81
232
0.85
1.03
t�60
1
0.85
4.4
0.1820
127
112
102
98
87
79
-232
0.9
1.08
1
0.85
-1A
0.18
HafdlePlank
5116
9.5
0.093"
shank.
0.222' HD
long
gaiv. ly. Siding
nail
Blind nail
2X4
wood W-
Fir
16
25
127
109
100
98
.85
78
-232
0.7
0.94
1.12
1
0.85
-1.4
0.18
30
127
107
99
96 1
83
76
1 232
0.7
0.911
1-16
1
0.85
4A
0.18
35
124
106
97
96
82
75
-232
0.73
1.01
1.19
1
0:85
4.4
0.18
40
122
104
96
94
81
74
-23.2
0.76
1.04
1.22
t
0.85
-1.4
0.18
45
120
103
95
93
80
74
-232
0.785
1.065
1.245_
1
0.85
4A
0.18
50
118
102
94
91
79
73
-232
0.81
1.09
127
1
0.95
-1.4
0-18
55
116
101
93:
90
78
72
-232
0.83
1.11
129
1
0.85
-1A
0.18
60
- 115
100
93
89
77
72
-232
0.85
1.13
1.31
1
0.85
-1A
0.18
10
995
84
79
74
65
61
-232
0.99
1.26
1.43
h>60
1
0.85
-1.8
0.18
0-15
111
101
92
86
78
71
1 -17.8
0.7
0.85
1 1.03
h560
1
0.85
-1A
0.18
20
111
98
89
86
76
69
-17-8
0.7
0.9
1 1.08
1
0.85
-1A
0.18
HardiePlank
5116
12
0.093"
shank
0222'HD
Xlong
r.
gahv. aii$nrg
nail
Blind nail
2X4
wood W-
Fir
16
25
111
96
88
86
74
68
-17.8
0.7
0.94
1.12
1
0.85
-1.4
0.18
30
111
94
86
86
73
67
27.8
0.7
0.98
1.16
1
0.85
-1.4
0.18
35
109
93
85
84
72
66
47.8
0.73
1.01
1-19
1
0.85
-tA
0.18
40
107
91
84
83
71
65
47.8
0.76
1.04
1.22
1
0.85
-1A
0.18
45
105
90
83
81
70
65
47-8
0.785
1.065
1.245
1
0.85
-1A
0-18
103
89
82
80
69.
64
-17.8
0.81
1A9
127
1
0.65
4.4
0.18
102
88
82
79
68
63.
-17.8
0.83
1-11
129
1
0.85
AA
0.18
W1,000
10187
81
78
68
63
-17.8
0.85
1.13
1.31
1
0.85
-1.4
0.18
83
74
69
65
57
54
-17.8
029
1.26
1.43
h>60
1
0.85
4.8
0.18
0-15
149
135
123
115
105
95
-31.9 _
9
f
0.65
':-1.4,
i0.18
HardiePiank
5116
5.25
0.093'
shank X
0:222' HD
X 2.0' long
ga[v. Siding
nag
Blind nail
2X4
wood W-
Fir
24
20
149
131
120
115
F $3�a•
.` 1.9
",
1
0. ;
;}7.4]
'108
25
149
128
118
115 i
-,
5 .
s39.9r
14.
" °
t.
'
- . "'.
i+ .
(ji.18
18
30
149
126
116
115
ra975
,. .9
0
9
' t 0
35
146
124
114
113
9
i{!1
1 Q'
40
143
122
113
111
9 a
a
Of.7
Q¢r.
t 1
1
8 ;
tfi 4
>0.18
45
140
121
112
109
"`
0 86
tii>65
1
8 :
� 14S'..18
50
138
119
110
107
ti
55
137
118
110
196
fv'
!O [
1
1
1.Y7
:�j.18
60 1
135 1
117
109
105
9
480
MAI
; 118
inn I
112
99
93
87
ht
.TP '`
( 3 .9'",
0
'Z6
q
! .
n .8.
Q18
15
ILE C
� 0 P
RONALD 1. OGAWA ASSOCIATES, INC.
16835 ALGONQUIN STREET #443
HUNTINGTON BEACH, CA 92649
714-292-2602
714-847-4595 FAX
PROJECT: RIO-2553-15
JAMES HARDIE BUILDING PRODUCTS, INC.
1-888-542 7343
info@jameshardie.com
Design Wind, Speed.
Design Wind, Speed,
4
Vet[ •
VsstlSb
(3-second gust mph)
(3-second gust mph)
Applicable to methods
luabte to methods
APp ••
specifiedin 120121BC,
specified in Exceptions 1
2014 FBC] Section
through 3 of [20121BC.
509.1.1. as determined by
2014 FBC] Section
(20121BC, 2014 FBC]
1609.1.1.
Figures 1609A. B. or C. Coefficients used in Table 6 calculations for Va
Wind exposurertpo,,Wind exposure catego Sid tg KProduct Stud Building'MeWidth Fastener Fastener FrameProduct Thidmess Spacing Heights r B C B C D Load
(inches) (itches) Type Spacing Type (inches) (feet) (PSF) Exp B I Ex. C I Fop D I 1KA1 K, I GC" GCd
0.093"
shank X 2X4
HardiePlank 5116 6.25 0.222" HD Blind nail wood W- 24
X 2.0' long Fir
galy. Siding
nail
0:093"
shank X 2X4
HardiePlank 5116 7.25 0222" HD Blind nail wood W- 24
X 2.0" long fir
galy. Siding
nail
0.093'
shank X
2X4
HardiePlank
5116
7.5
0.222" HD
Blind nail
wood W-
24
X 2.0" long
Fir
galy. Siding
nail
0.093'
shank X
2X4
HardiePlank
5116
8
OM"HD
Blind nag
wood W-
24
X 2.0" long
Fir
galy. Siding
nail
0.093"
shank X 2X4
HardiePlank 5116 8.25 0.222" HD Blind nag wood W- 24
X 2.0" long Fir
galy. Siding
20
119
1 105
96
1 92
81
74
1 -20A
0.7
1 0.9
1 1.08
25
119
103
94
92
80
73
-20A
0.7
0.94
1.12
30
119
101
92
92
78
72
-20A
0.7
0.98
1.16
35
117
99
91
90
77
71
10.4
073
1.01
1.19
40
114
98
90
88
76
70
-20.4
0.76
1.04
122
45
112
96
89
87
75
69
-20A
0.785
1.065
1.245
50
111
95
88
86
74
68
-20A
021
1.09
127
55
109
94
88
85
73
68
-20A
0.83
1.11
129
60
108
1 94
87
1 84
73
67
j -20.4
0.85
1.13
1 131
100
89
79
74
69
61
58
1 -20A
0.991
126
1 1A3
)A5
114
104
94
89
80
73
-18.9
0.7
0A5
1.03
20
114
101
92
89
78
71
-18.9
0.7
0.9
1.08
25
114
99
91
89
77
70
-18.9
0.7
0.94
1.12
30
114
97
89
89
75
69
-18.9
0.7
0.98
1.16
35
112
95
88
87
74
68
-1&9
0.73
1.01
1.19
40
110
94
87
85
73
67
-18.9
0.76
1.04
1?2
45
108
1 93
86
1 84
1 72
67
48.9
0_785
1.WS
124E
50
106
92R89
82
71
66
-18.9
0.81
1.09
127
55
105
91
81
70
65
-18.9
0.83
1.11
129
60
104
90
80
70
65
-18.9
0.85
1.13
1.31
100
86
76.
67
59
55
-1&9
0.99
1.26
1.43
3.15
112
102
87
7
72
0.-
610
20
112
99
87
7
25
112
97
87
7 y
raj
o30
112
95
1 87
7
?
z is
35
110
94
88
85
7 , ,,
71
. -183
0 ,
{Ojl
40
108
92
85
84
7'f ei
?SrS 3
to
13Z
45
106
91
184
82
ZE
I
ear
5
Mi
50
105
1 90
1 83
81
7WYN
fe%fi 1
.. .
4d
13Z
1 0.85 -1.4 0.18
1 0.85 4 A 0.18
1 0:85 -tA 0.18
1 0.85 -lA 0.18
1 0.85 -1A 0.18
1 0.85 AA 0.18
1 0.85 -1.4 0.18
1 0.85 4.4 0.18
1 0.85 4.8 0.18
1 0.85 -IA 0.18
1 .0.85 -lA T.
1 0.85 -1.4 0.18
1 0.85 -1.4 0.18
1 0.85 -1.4 0.18
1 0.1 -1.4 0.18
1 0.F -1.4 0.18
1 0.85 -1A 0.18
1 0.85 -1A 10.18
1 0.85. 4.4 10.18
6
16
RONALD 1. OGAWA ASSOCIATES, INC-
16835 ALGONQUIN STREET #443
HUNTINGTON, BEACH, CA 92649
714-292-2602
714-B47-4595 FAX
PROJECT: RIO-2553-15
JAMES HARDIE BUILDING PRODUCTS, INC-
1-888-542-7343
in[o@jameshardie.com
\\1{II{IIIIII////
G� ArF �.
2012 IBC, 2014 FBC
2012IBC, 2014 FBC
2412
= 1
p
$TA 'E VF °
a]o �:••
{{E�
Coefficients used. in Table 6-calculations for V,a
Allowable, Ultimate
Design Wind, Speed,
V�4
(3-second gust mph)
Allowable, Nominal
Design Wind, Speed,
V .d5.fi
(3-second'gust mph)
Applicable to methodsFLospeciffed
12 113C,
zo74FBc is
1609.1.1. as determined j
[2012IBC, 2014FBC)
Figures 1609A, B. or C.
Applicable to methods
a 1through 3��8C
2014 FBC] Section
1609.1-1.
Wind exposure category
Wind exposure category
Siding
I
Product
Product
Thicknim
(inches)
Width
('inches)
Fastener
Type
Fastener
Spacing
Frame
Type
Stud
Spacing
(inches)
Building
Height37
(feet)
B
C
D
B
C
D
Allowable
Design,
Lid
(PSF):
Exp B
Exp, C
Exp D
Ka
I Kn
I 6Cr,
I GCP
HardiePlank
5/16
9.25
0.093'
shank
0.222'HD
X.2.0" long
galy. Siding
nail
Blind nag
2X4
wood W-
Fir
24
0-15
1 105
95
87
81
74
67
-16.0
0.7
0.85
1:03
hsfi0
1
0.85
-0A
10.18
20
105
93
85
81
72
66
-16.0
0.7
0.9
1.08
1
0.05
-IA
0-18
25
105
91
83
81
70
64
-16.0
0.7
0.94
1.12
1
0.95
-11A
10.18
30
105
1 89
82
1 81
1 69
63
-16.0
0.7
1 0.98
1 1.1B
1
0.85
-1A
0.18
35
103
88
81
80
68
62
-16.0
0.73
1.01
1.19
1
0.85
4A
0-18
40
101
86
80
78
67
62
-16.0
0.76
1.04
122
1
0.85
AA
0.18
45
99
85
79
77
66
61
46.0
0.785
1.065
1245
1
0.85
-IA
0.18
50
98
84
78
76
65
60
-16.0
0.81
1.09
127
1
0.85
-1 A
0.18
55
97
84
77
75
65
60,
-16.0
0.83
t.11
t29
1
0.85.
-tA
0.18
60
95
83
77
74
64
60
16.0
0.85
1.13
1.31
1
0.85
-1.4
0.18
100
79
70
66
61
54
51
46.0
0.99
1.26
1
0.85
-1:8
0.180-15
HardiePlank
5116
9.5
shank X
0.222" HD
X lv.2.long
galvnailSiding
nail
Blind nail
2X4
wood W-
Fr
24
104
94
85
80
73
66
-15.5
0.7
0.85
t�0
1
0.85
-tA
0,18
20
104
91
83
80
71
65'
-15.5
0.7
0.9
1
0.85
-1A
0.180-09T
25
104
89
82
80
69
63
-1&5
0.7
0.94
d1.43v60
1
0-85
-tA
0.18
30
104
88
80
80
68
62
15S
0.7
0.9S
1
0.85
-1.4
0.18
35
101
86
79
79
67
62
-15.5
0.73
1_01
1
0:85
-1-4
0.18
40
99
85
78
77
66
61
-15.5
0.76
1.04
1
0,85
-1A
0.18
45
98
84
78
76
65
60
-15.5
0.785
1.065
1245
1
0.85
-1.4
0.18
50
96
83
77
75
64
60
46.5
0.81
1A9
127
1
0.85
-1A
018
55
95
82
76
74
64
59
-155
0.83
1.11
129
1
0.85
4-4
6.88
60
94
82
76
73
63
59
-15.5
0,85
1.13
121
1
0.85
-1.4
0.18
100
78
69
65
60
53
50
-15.5
0.99
1.26
1.43
h>60
1
0.85
-1.8
0.18
HardiePlank
5116
12
0:093'
shank X
0 222" X
X 20' long,
galv.8lding
Blind nail
2X4
wood W-
Fir
24
0-15
91
82
75
70
64
58
A"
0.7
0.85
1-03
hM
1
0.85
-1A
0.18
20
91
80
73
70
62
57
-11.9
0.7
02
US
1
0,85
4A
0.18
25
91
78
72
70
61
56
-11.9
0.7
0-94
1.12
1
0.85
-1.4
0.18
30
91
77
70
70
59
55
-11,9
0.7
em
1?I6
1
0.85
4A
0.18
35
89
76
70
69
59
54
-11.9
0.73
1.01
119
1
0.85
AA
0.18
40
87
74
69
67
58
53
-11.9
0.76
1-04
122
1
0.85
-1.4
0.18
45
86
74
68
66
57
53
-11.9
0.785
1.065
1.245
1
0.85
-1.4
0.18
50�8141
67
65
56
52
-tt.9
41.9
0.81
t.09
127
1
0.85
-t.4
0.t8nail
55
67
65
56
52
0.81
1.09
127
1
0.85
-1.4
0.18
60
66
64
55
51
1t.9
0.85
1.13
.t 31
1
0.85
-1.4
0.18
100
57
53
47
44
11.9
0.991
126
1.43
h>60
1
0.05
4-8
0.16
HardiePlank
SH6
525
No. 11 ga.
X 1-314"
bong
Roofing
nail
Blind nail
2X4
wood
Hem -fir
16
0-15
264
240
218
205
186
169
-100.8
0.7
OAS
1.03
1>!950
1
0.85
-IA
0.18
20
264
233
213
205
180
165
-100.8
0.7
02
1.08
1
0.85
-1.4
0.18
25
264
228
209
205
177
162 1
-10o:8
0.7
0.94
1.12
1
0.85
AA
0.18
30
264
223
205
205
173
159
-100.8
0.7
0.98
1.16.
1
0.85
-1A
0.18
35
259
220
203
200
170
157
-10o.8
0.73
1.01
1-19
1
DAS
-1A
0-18
40
254
217
200
196
168
155
400A
0.76
1.04
122
1
0.85
4A
0.18
45
249
214
198
193
166
153
-boos
o.7s5
1.065
1245
1
0.85
-IA
0-18
50
246
212
196
190
164
152
-100.8
0:81
1.09
127
1
0.85
-1.4
0.18
55
243
210
195
188
163
151
-100:8
0.83
1-11
129
1
0.85
-1.4
0.18
60
240
208
193
186
161
150
-100.8
0.85
1-13
1.31
t
0.85
-t.4
0.18
100
198
176
165
154
136
128
-10D.8
0.99
1.26
1A3
Iv60
1
0.85
-1.8
0.18
No.11 ga.
X 1.3W
HardiePlank 5116 6.25. long Blind nail
nail
G-15 236 214 195 183 166
20 236 208 190 183 161
25 236 204 187 183 58
30 236 200 184 183 5 R
2X4 35 231 197 181 179 ,t2r�
wood 16 40 227 194 179 176 0
Hem -fir 45 223 192 177 173 )j
50 220 189 175 17014
55 217 188 174 168
60 214 186 173 166 1`
100 177 157 148 137 122
151
-80.6
0.7
0.85
1A3
h580
y
`
1
0.85
AA
0.18
OR 'M.W.
.85
�.• 4
W 8
fiv` s
0"
1
)
0
£Y 8
AZi
.8 r.
0. _
tsj
4 _
f!? 8
4
73i11-o
; 3
6122}
+ k
1
e
i"1IMRoofing
7A.
.78 i,
h
1
4t ,'
;(8
31ik
. 0. 1:
71
W
9
"_1j ?
? f8
0:
7
'r0
..
1
114
=11ti<
11fi€
.. D. !t 0.
(?t ?a ik8
17 FILE COPY
RONALD 1. OGAWA ASSOCIATES, INC.
16835 ALGONQUIN STREET #443
HUNTINGTON.BEACH, CA 92649
714-292-2602
714-847-4595 FAX
PROJECT: RIO-2553-15
JAMES HARDIE BUILDING PRODUCTS, INC.
1-888-542-7343
info@jameshardie.com
`�\p11111II11111111I/1
1`N,Q: , OGcjK�.,,IN
���
2012 BC, 2014 FBC
2012I13C 2014 FBC
24 2 `
1
- STATE F
'!(Q
�':�/• FLOAIQQ=•
�''�.�irtTFRED
I/INlll 111111
Coefficients used in Table 6, calculations for V e
Allowable, Ultimate
Design Wind, Speed,
a
v,n ,
(3-second gust mph)
ARowable, Nominal
Design Wind, Speed,;
6.6
v,W ,
(3-second gust mph)
Applicabletomethods
specified [zo
2014 FBCI Section
1612012 I as determined
[2092 IBC, 201a FBC)
Figures 1609A, B. or C.
App�bletorrethods
speafied in
9-ugh 3 Exceptions
optio c,1
2014 FBC] Section
16119.11
.1.1.
n
t
s'
[7ToduclThickness
Product
(inches)
Width
(ruches)
Fastener
Type
Fastener
Spacing
Frame
Type
Stud
Spacing
(inches)
Building
Heiglit37
(feet)
B
C
D
B
C
D
AB b1
Design
toad
(PSF)
Exp B
EV C
Ev D
K.
K,
GC.
GCd
HardiePlank
5116
7.25
No. 11 ga.
X 1-314"
long
Roofing
nail
Blind nail
2X4
wood
Hem -fir
16
0-15
216
196
178
167
152
138
-672
0.7
0.85
1.03
hsW
1
0.85
-1,4
0.18
20
216
190
174
167
147
135
-672
0.7
0.9
1.08
1
0.851
AA
10.18
25
216
186
171
167
144
132
-67.2
0.7
0.94
T12
1
0.851
A A
10.18
30
.216
182
168
1 167
1 141
130
-672
0.7
0.98
1.16
1
0.85
-1.4
0.18
35
211
180
165
164
139
128
-672
0.73
1.01
1.19
1
0.85
AA
0.18
40
207
177
163
160
137
127
-672
0,761
1.04
122
1
0.85
AA
0.18
45
204
175
162
158
135
125
-672
0.785
1.065
1245
1
0.85
-lA
0.18
50
201
173
160
155
134
124
-672
0.81
1.09.
127
1
0.85
AA
0.18
55
198
171
159
153
133
123
-672
0.83
1-11
12.9
1
0.85
AA
0.18
60
196
170
158
152
132
122
-672
0.85
1.13
1.31
1
10.85
AA
0.18
100
162
1 144
135
126
111
1 104
-672
099
1.26
1.43
h>b0
1
0.85
-1.8
0.18
HardiePlank
5116
7.5
No. 11 ga.
X 1-3/4"
long
Roofing
nail
Blind nail
2X4
wood
Hem -fir
16
15
1
19
74
1
.5
1
20
211
186
170
164
1 44
132
54.5
0.7
Oa
1.08
t
0.85
-lA
0.18
25
211
182
167
1fi4
141
129
-6C5
0.7
094
1.12
1
0.85
-lA
0.18
30
211
179
164
164
138
127
-645
0.7
0.98
1.16
1
0.85
4A
0-18
35
207
176
162
160
136
126
-64.5
0.73
1.01
1.19
1
0.85
- -4
0.18
40
203
173
160
157
134
124
-64.5
0.76
1.04
122
1
0.85
4A
0.18
45
200
171
158.
155
133
123
-64.5
0,785
1.065
1245
1
0.65
-1.4
0.18
50.
1 196
1 169
157
1 152
131
122
-64.5
0.61
1 1.09
127
1
0.85
4.4
0.18
55
1194
168
156
150
130
121
-64.5
0-83
i.1t
129'
1
0.85
-lA
0.18
60
192
166
154
149
129
1 120
-64.5
0.85
1.13
1.31
1
0.85
-lA
0.18
100
1 159
1141
132
123
W9
102
1 -64.5
0.99
126
143
tN0
i
102514.810.181
HardiePlank
5116
8
No. 11 ga.
X 1-3/4'
long
Roofing
nail
Blind nag
2X4
wood
Hem -fir
16
0-15
203
185
168
158
143
130
59.7
0.7
0.85
1.03
NX0
1
0.851
4.a
10.18
20
203
179
164
158
139
127
-59.7
0.7
09
1.08
1
0.85
-1.4
10.181
25
203
176
161
158
136
125
59.7
0.7
0,94
1.12
1
0.85
-1.4
10.181
30
203
172
158
158
133
122
-59.7
0.7
0.98
1.16
1
0.85
4-4
0.18
35
199
169
156
154
131
121
59.7
1 0.73
1.01
1 1.19
1
0.85
4A
0.18
40
195
167
154
151'
129
119
59.7
0.76
1.04
1 122
1
0.85
4A
0.18
45
192
165
153-
149
128
118
-59.7
0.785
1.065
1:245
1
0.85
4.4
0.18
50
189
163
151
146
126
117
-59.7
0.81
1.09
127
1
0.85
4.4
0.18
55
18T
162
150
145
125
116
59.7
0.83
1.11
129
1
0.85
-1.4
0.78
60
1 B5
160
149
143
124
115
-59.7
0.85
1.13
1.31
1
0.85
AA
0.18
t00
153
135
127
118
105
98
59.7
0.99
126
1.43
li;M
1
0.85
-1.8
10.18
HardiePlank
5116
8.25
No. 11 ga.
X 1-314"
long
Roofing
nail
Blind nail
2X4
wood
Hem -fir
16
0-15
200
181
165
155
140
128
57.6
0.7
0.85
1-03
fs50
1
0.85
-1.4
10.18
20
200
176
161
155
136
125
-57.6
0.7
09
US
1
0.85
4.4
0.18
25
200
172
158
155
133
122
57.6
0.7
1 0.94
1.12
1
0.85
4.4
0.18
30
200
169
155
155
131
120
-57.6
0.7
0.98
1.16
1
0.85
4A
0.18
35
196
166
153
151
129
119
-57.6
0.73
1.01
1.19
1
0.85
-1 A
0.18
40
192
164
151
148
1 127
1 117
-57.6
0.76
1.04
122
1
0.85
4.4
0.18
45
189
162
150
146
125
1 116
57.6
0.785
1.065
1245
1
0.85
-1.4
0.18
50
186
160
148
144
124
115
57.6
Eat
Tug
127
1
0.85
4.4
GAS
55
183
159
147
142
123
114
-57.6
0.83
1.11
129
1
0.85
-lA
0.18
60
181
157
146
140
122
113
5T.6
0.85
1.13
1.31
t
0.85
4A
0.18
100
150
133
125
116
103
97
-57.6
0.99
126
1.43
h�W
1
0.85
4 8
0.18
HardiePlank
5116
9.25
No. 11 ga.
X15l4"
long
Roofing
nail
Blind nag
2X4
wood
Hemfir
16
0-15
187
170
154
145
131
119
-WA
0.7
0.85
1.03
hsW
1
0.85
AA
0.18
20
187
165
150
145
128
116
1 50.4
0.7
0.9
1.08
1
0.85
-1.4
0.18
25
187
161
148
145
125
114
50A
0.7
0.94
1.12
1
0.85
AA
0.18
30
187
158
145
145
122
112
-50A
0.7
0.98
1.16
1
0,85
-IA
0.18
35
183
156
143
142
11
8
,. 01
1
A_.
- x
0.8'
40
179
153
142
139
L
1
:10
Oar.
;,1'
l 'A`.
$ .
;0.1-4
45
176
151
140
137
.18
50
174
150
139
135
a
f
1
0.
-1tY
10.
55
172
148
138
133
Tj1.
0AW.
14.:dt
60
170
147
137
131
11_
l:. A ,
5
1
I
d 0. -,
11.4i
100
140
124
117
109
9D h
+ OA
;f 26•
�t "'
_},, 0.>�
1
78
4
18
RONALD I. OGAWA ASSOCIATES, INC..
16835 ALGONQUIN STREET #443
HUNTINGTORBEACH, CA 92649
714-292-2602'
714-847-4595 FAX
PROJECT: RIO-2553-15
JAMES HARDIE BUILDING PRODUCTS, INC.
1-888-542-7343
info@jameshardie.com
2012 IBC, 2014 FBC
2012 IBC. 2014 FBC
Allowable, Ultimate
Allowable, Nominal
Design Wind, Speed,
Design Wind, Speed,
V,a°.
Va,dssr
(3-second gust mph)
(3-second-gust mph)
Applicable to methods
Applicable to methods
specified in (2012 IBC,
specified in Exceptions 1
2014 FBC] Section
through 3 of (201216C,
1609.1.1. as determined by
2014 FBC] Section
[2012IBC, 2014FBC]
1609.1.f.
Figures 1609A, B, or C.
Coefficients used In Table 6 calculations for V„ o.
Wind exposure category
Wind exposure categoryl
Siding
K
Product
Stud
Building
Allowable
Product
Thickness
Width
Fastener
Fastener
Frame
Spatting
Heights r
B
C
D
B
C
D
Design
I
I
cinches)
(inches)
Type
Spacing
Type
(inches)"
(feet)
Load
(PSF).
Exp 8
Exp.0
EV D
Ka
Ka
GC,
GC,
0-15
141
128
117
110
99
90
1 28.9
0.7
0.85
1.03
hs60
1
0.85
-1,4
0.18
20
141
125
114
110
97
88
1 728.9
0.7
0.9
1.03
1
0.85
-1.4
0.18
No.8-X
25
141
122.
112
110
94
87
-28.9
0.7
0.94
1.12
1
0.85
-IA
0.18
1.25"'long
30
141
119
110
1 110
93
85
48.9
0.7
0.98
1.16
1
0.85
AA
0.18
X 0.376"
2X4
35
138
118
108
107
91
84
-28.9
0.73
1.01
139
1
0.85
4A
0.18
HardiePiank
5116
12
head
Blind Nail
20ga_
24
40
136
116
107
105
90
83
-28.9
0.76
1.04
1,22
1
0.85
-1.4
0.18
diameter
Metal
45
133
115
106
103
89
82
-2a.9
0.785
1245
1
0.85
-1.4
0.18
ribbed
wafer head
131
i13
105,
i02
88
81
28.9
081
�1.065
og.
127
1
o_es
-t:a
o.1a
55
130
112
104
101
87
81
-28.9
0.83
.11
129
1
0.85.
-1.4
0.18
screw-
60
128
111
103
99
86
80
-28.9
0.85
1.13
1.31
1
0.85
-f.4
0%
100
106
-94
88
82
73
68
-28.9
099
1.26
1 1.43
jh>60
1 1
0.85
-1.8
10.18
1. Screws shall penetrate the metal training at least three full threads.
2. Knurled shank pins shall penetrate the metal framing at least 114 inch.
3. Building height = mean roof height (in feet) of a building, except that eave height shall be used for roof angle O less than or equal to 10" (2-12 roof slope).
4. Vuh = the ultimate design wind speed (3-second gust mph) as determined by (2012 IBC, 2014 FBC] Figures 1609A; 16098, or 1609C; ASCE 7-10 Figures 26.5-IA, 26.5-18, ar 26.54C.
5. Vasd = the nominal design wind speed applicable la methods specified in Exceptions 1 through 3 of [2012 IBC, 2014 FBC] Section 1609.1.1.
6. The wind speeds in [2012 IBC, 2014 FBC] Figures 1609A, 1609B and 1609C are ultimate design wind speeds, Vult, and shall be converted in accordance with [2012 IBC. 2014 FBC) Section 1609.3.1
to nominal design wind speeds, Vasd, when the provisions of the standards referenced in [2012 IBC, 2014 FBC]iSecdon 1609.1.1. Exceptions 1 through 3 are used.
7.'Linear interpolation of building height and wind speed is permitted.
8. Wind speed design, assumptionsper Analytical Method in ASCE 7-10 Chapter 30 C&C Part 1 and Part 3:14,=1, K,=0.65, G%---1.4 (h<<60), GC,=1.8 (tu60), GCP,=0.18_
LIMITATIONS OF USE:
1) Fastener pullout must:be evaluated when installed a species of wood studs other than. that which was tested_
2) In High Velocity Hurricane Zones (HVHZ) install per Miami -Dade County-Florida,.NOA 15-0122.04.
57
CONCRETE:
*SHALL MEET A MINIMUM COMPRESSIVE STRENGTH OF 3000PSI
Q 28 DAYS.
*SLUMPS SHALL BE 4" MIN AND 6" MAX.
*MIN 3% AIR ENTRAINMENT.
*MAX
WATER/CEMENT RATIO OF 0.55.
I REINFORCING:
*SHALL MEET ASTM STANDARDS FOR 60 GRADE.
*ALL REINFORCING STEEL SPLICES SHALL BE LAPPED A
MINIMUM 40 BAR DIAMETER, ALL HOOKED REINFORCING BARS
SHALL HAVE AN EXTENSION OF 12 BAR DIAMETERS BEYOND
BEND.
*ALL OUTER BARS IN FOOTERS SHALL HAVE CORNER BARS
WITH A MINIMUM 40 BAR DIAMETER LAP.
ALL FOOTER BARS SHALL HAVE A MIN. 3" CONC. COVER WHERE
THE CONC. IS CAST AGAINST EARTH, OR 12 , WHERE CONC. IS
FORMED AND EXPOSED TO EITHER WEATHER OR EARTH.
WOOD:
*ALL LOAD BEARING STUDS TO BE: #2 SOUTHERN YELLOW
PINE, #2 DOUGLAS FIR -LARCH, #2 SPRUCE -PINE -FIR, OR BETTER
GENERAL:
1. ALL PILINGS SHALL BE 14" DIA. CAST -IN -PLACE (AUGERED )
PILES, 22 TON CAPACITY AND 13 TON UPLIFT CAPACITY AND 20'
0" LONG. (PILES SHALL BE INSTALLED BY AN EXPERIENCED
PILING CONTRACTOR)
2. PRIOR TO START OF WORK, CONTRACTOR SHALL SUBMIT TO
THE ARCHITECT/ENGINEER THE FOLLOWING:
2.1 - DRILLING EQUIPMENT TO BE USED
2.2 - INSTALLATION PROCEDURES
2.3 - GROUT DESIGN MIX.
2. PILINGS SHALL BE INSTALLED WITHIN AN ACCURACY OF 2"
FROM DESIGN LOCATION.
3. GROUT FOR PILINGS SHALL BE 5000PSI AT 28 DAYS.
4. REINFORCING STEEL SHALL BE DEFORMED BARS,
CONFORMING TO ASTM A-615 GRADE 60.
INSTALLATION:
1. ALL PILES SHALL BE INSTALLED TO THE DEPTHS SHOWN ON
THE DESIGN DOCUMENT'S AND IN ACCORDANCE WITH THE
2010 FLORIDA BUILDING CODE SECTION 1810.
2. THE AUGER SHALT, BE USED TO RETAIN THE SHAPE OF THE
HOLE AND SHALL BE WITHDRAWN AT A SLOW PACE IN ORDER
TO PREVENT THE ADJACENT SOIL FROM COLLAPSING.
3. CONTRACTOR SHALL DOCUMENT PILE LOCATIONS, DATE OF
INSTALLATION, AND LENGTH OF PILES.
TESTING:
1. PROVIDE FOUR GROUT CYLINDERS FOR EACH TEN CUBIC
YARDS OF GROUT PLACEMENT. BREAK ONE CYLINDER AT 7
DAYS, ONE AT 14 DAYS, ONE AT 28 DAYS AND RETAIN ONE FOR
FUTURE USE.
GENERAL SITE NOTES:
CONTRACTOR/OWNER TO HAVE CERTIFIED FLORIDA
SURVEYOR LAYOUT BUILDING ON LOT TO ASSURE THAT NO
SETBACKS OR EASEMENTS ARE ENCROACHED AND TO VERIFY
LOCATIONS OF EXISTING/ADJACENT, WELLS, SEPTIC SYSTEMS,
AND TREES.
THE ARCHITECT ASSUMES NO RESPONSIBILITY FOR EXISTING
CONDITIONS ON THE LOT INCLUDING, BUT NOT LIMITED TO,
HAZARDOUS MATERIALS, UNSTABLE SOIL, SETTLEMENT, OR
ANY OTHER UNFORESEEN CONDITION.
POSITIVE DRAINAGE SHALL BE MAINTAINED AT THE SITE
DURING CONSTRUCTION. REMOVE FREE WATER FROM
EXCAVATIONS BEFORE PLACING CONCRETE.
IMMEDIATELY PRIOR TO REINFORCING STEEL PLACEMENT,
ALL BEARING SURFACES OF ALL FOOTINGS AND FLOOR SLAB
AREAS SHALL BE COMPACTED USING HAND OPERATED
MECHANICAL TAMPERS. ALL LOCALIZED AREAS WHICH HAVE
BEEN LOOSENED BY EXCAVATION OPERATIONS SHALL BE
ADEQUATELY RE -COMPACTED.
SOIL BEARING CAPACITY: 2500 PSF
BEFORE PLACEMENT OF ANY SLAB ON GRADE, ALL SOIL
BE TERMITE TREATED/POISIONED.
PALM TO REMAIN
(LOCATION T.P.D.)
*ELECTRICAL CONTRACTOR SHALL COMPLY WITH 2O11 N.E.C. AND ALI, OTHER APPLICABLE
CODES.
*ELECTRICAL CONTRACTOR SHALL VERIFY ALL ELECTRICAL LOADS, RISER DIAGRAM, &
ELECTRICAL PLAN & NOTIFY THE G.C. OF ANY ERRORS OR DISCREPENCES PRIOR TO
INSTALLATION.
*ELECRICAL CONTRACTOR IS TO SIZE BRANCH CIRCUITS. A MAXIMUM VOLTAGE DROP OF 3
PERCENT IS PERMITTED.
*ALL OUTLETS, SWITCHES/DIMMERS, AND LIGHT FIXTURE LOCATIONS TO BE VERIFIED BY
OWNER ON WALK-THRU WITH ELECTRICAL CONTRACTOR
*ALL DEVICES SHALL BE SMOOTH TYPE (WHITE) UNLESS OTHERWISE NOTED.
*ALL RECEPTACLES INSTALLED OUTDOORS, BATHROOMS, GARAGE, LAUNDRY, AND
KITCHENS TO HAVE GROUND FAULT CIRCUIT INTERRUPTER ALL OTHER RECEPTACLE
LOCATIONS SHALL BE PROTECTED BY A LISTED ARC -FAULT CIRCUIT INTERRUPTER
COMBINATION -TYPE, INSTALLED TO PROVIDE PROTECTION TO THE BRANCH CIRCUIT PER
NEC 210.12(B).
*PROVIDE/INSTALL TAMPER -RESISTANT RECEPTACLES IN ALL AREAS AS SPECIFIED BY NEC
210.52.
*UNLESS OTHERWISE NOTED, MINIMUM SIZE WIRE SHALL BE #12 "AWG", EXCLUDING
CONTROL WIRING.
*VERIFY ALL CONDUCTORS AND BREAKERS W/ EQUIP. MANUR SPECS.
*ALL ELEC. SWITCHES SHALL BE 48" A.F.F. AND ALL RECEPTACLES SHALL BE 12" A.F.F. UNLESS
OTHERWISE NOTED.
*SMOKE DETECTORS TO BE INTERCONNECTED AND HARD -WIRED AND MEET ALL
APPLICABLE LOCAL BUILDING CODES.
*ELECTRICAL RECEPTACLES TO BE INSTALLED IN ALL ADDITIONAL LOCATIONS AS
REQUIRED BY CODE EVEN IF NOT SHOWN ON THE DRAWINGS.
*ALL ELECTRICAL DEVICES LOCATED IN NON -CONDITIONED SPACE TO BE OUTDOOR
"WEATHER RESISTANT" RATED. ALL ELECTRICAL FIXTURES LOCATED IN NON -CONDITIONS
SPACE SHALL BE MARKED "SUITABLE FOR WET LOCATION" OR "SUITABLE FOR DAMP
LOCATION".
DRIVEWAY
o-
MICHI"IAN AVE
*CONTRACTOR TO VERIFY LOCATION OF ALL UTILITIES AVAILABLE AT SITE BEFORE PROCEEDING W/ CONSTRUCTION.
*CONTRACTOR, SUBCONTRACTOR, MATERIAL SUPPLIER, ETC. SHALL MAKE THEMSELVES FAMILIAR WITH THE CONTRACT DOCUMENTS AND SHALL VERIFY ALL
DIMENSIONS, CONDITIONS AT JOBSITE, PLANS, SPECIFICATIONS, ETC. AS APPLICABLE AND REPORT ANY DISCREPANCIES, ERRORS OR OMISSIONS TO THE
ARCHITECT PRIOR TO ANY WORK BEING PERFORMED. OTHERWISE, THE ARCHITECT ASSUMES NO RESPONSIBILITY FOR ANY ERRORS AND THE CONTRACTOR,
SUBCONTRACTOR, MATERIAL SUPPLIER, ETC. SHALL ASSUME FULL RESPONSIBLLI-, Y FOR ERRORS AND/OR DELAYS AND CORRECT THEM AT THEIR OWN EXPENSE.
LANCE A VOGL SHALL NOT BE LIABLE FOR ANY LOSS, DAMAGE OR INCONVENIENCE ARISING FROM INACCURACIES.
*THE ARCHITECT HAS NOT BEEN RETAINED FOR THE SUPERVISION OR THE ADMINISTRATION OF THE EXECUTION OF THE WORK OF THIS PROJECT.
*EACH CONTRACTOR SHALL BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES FOR SAFETY PRECAUTIONS
AND SHALL COMPLY WITH THE REQUIREMENTS OF O.S.H.A, APPLICABLE BUILDING CODES, AND ALL GOVERNMENTAL AGENCIES HAVING JURISDICTION.
*EACH CONTRACTOR SHALL MAKE ALL ARRANGEMENTS FOR, OBTAIN AND PAY FCR ALL PERMITS, TESTS, INSPECTIONS, AND APPROVALS REQUIRED FOR HIS
PORTION OF THE WORK.
*CAULKING USING A ONE -PART URETHANE PRODUCT SHALL BE APPLIED AT ALL JUNCTIONS OF WALL AND WINDOW AND DOOR FRAMES WITH ABUTTING WALL
SURFACES TO PROVIDE A WEATHERTIGHT, WATER-RESISTANT INSTALLATION.
*DUROCK SHALL BE USED IN ALL WALL TILE AND FLOOR THE LOCATIONS OTHER THAN OVER CONCRETE. ALL GLASS AT SHOWERS/TUBS TO BE TEMPERED.
*PROVIDE EGRESS WINDOW UNITS Q ALL NEW SLEEPING AREAS AS REQUIRED BY CODE.
*CONTRACTOR(S) TO COORDINATE WALL BLOCKING REQUIREMENTS W/ CABINETRY AND SHELVING LOCATIONS.
*ALL WOOD IN CONTACT WITH MASONRY TO BE PRESSURE TREATED SYP MEETING AWPA STANDARDS TO A MINIMUM 0.4 PCF RETENTION. ALL METAL
CONNECTORS, NAILS, & SCREWS IN CONTACT WITH PRESSURE TREATED LUMBER SHALL BE HOT -DIPPED GALVANIZED AND CONFORM TO ASTM STANDARDS.
*AIL EXTERIOR DOORS/WINDOWS IN LOCATIONS SUSCEPTABLE TO SOLAR HEAT GAIN SHALL BE A MIN. OF LOWE 240.
*ALL WINDOW/DOOR DIMENSIONS ARE NOMINAL (*VERIFY ROUGH OPENINGS WITH MANUFACTURER)
*REFER TO BUILDING PLANS & ELEVATIONS FOR DOOR/WINDOW TYPE & CONFIGURATION.
*INTERIOR DOOR STYLE AND TRIM STYLE TO BE VFRTFT RD BY OWNTFR Do (-)R LIARDIXI ARP Tn RP CPT Pr Mn Rv nWe MV
*WALL AND CEILING FINISHES SHALL HAVE A SMOKE -DEVELOPED INDEX OF NOT GREATER THAN 450 PER 2014 FBC R302.9.3
*INSULATION MATERIALS, INCLUDING FACINGS, SUCH AS VAPOR RETARDERS AND VAPOR -PERMEABLE MEMBRANES INSTALLED WITHIN FLOOR/CEILING
ASSEMBLIES, ROOF/CEILING ASSEMBLIES, WALL ASSEMBLIES, CRAWL SPACES AND ATTICS SHALL HAVE A FLAME SPREAD INDEX NOT TO EXCEED 25 WITH AN
ACCOMPANYING SMOKE -DEVELOPED INDEX NOT TO EXCEED 450 PER 2014 FBC SECTION R203.10.
*THE SPIRAL STAIRCASE SHALL PROVIDE A MINIMUM CLEAR WIDTH AT AND BELOW THE HANDRAIL OF 26" WITH EACH TREAD HAVING A 7 2' MIN. TREAD DEPTH AT
12" FROM THE NARROWER EDGE. ALL TREADS SHALL BE IDENTICAL, AND THE RISE SHALL BE NO MORE THAN 9 2'. A MINIMUM HEADROOM OF 0 6" SHALL BE
PROVIDED.
PAVER WALK
UP
-rN
M
-4-O
AI
COVE
!AinJ-SPLIT
JUTGUOft UNIT J
*PROPOSED 1 1/2-STORY
SINGLE FAMILY
RESIDENCE
SCREENED
PORCH
*COVERED
l SITE PLAN
Al 1/4„=l'-(y" -l'0" HALF SIZE
N
m
3
1
INDEX OF DRAWINGS
Al SITE PLAN & PROJECT DATA
A2 FOUNDATION, FLOOR, & FLOOR FRAMING PLANS
A3 ROOF/ROOF FRAMING PLANS, SCHEDULES, & PLUMBING RISER
A4 ELEVATIONS
A5 BUILDING SECTION
A6 SECTIONS & DETAILS
A7 ELECTRICAL PLAN
AREA CALCULATIONS:
1ST FLOOR CONDITIONED SPACE ........... 875 S.F.
LOFT.......................................................................166 S.F.
COVERED DECKS/PORCHES ......................115 S.F.
TOTAL UNDER ROOF....................................1,156 S.F.
PAVER DRIVEWAY/WALKS .........................648 S.F.
*ALL AREAS CALCULATED TO OUTSIDE DIMENSIONS
DATA &DESIGN PRESSURE SCHEDULE
1.WIND LOADS BASED ON FLA. BUILDING CODE 2014, ASCE 7-10 & 2011 N.E.C.
2. TYPE OF CONSTRUCTION: WOOD FRAME
3. BUILDING DESIGN: ENCLOSED
4. WIDTH OF END ZONE: 3'
5. BASIC WIND SPEED: 165 MPH 3 SECOND GUSTS � f' R E PL NS AND ALL PRdpQgEp WQkK
6. BUILDING CATEGORY: II ARE SUBJECT TO ANY CORRECTIONS
7. BUILDING MEAN HEIGHT: 20 0 D REQUIRED QY FIELD INSPECTORS THAT
8. EXPOSURE CATEGORY C MAY €ji' NEC',ESSA,DY IN ORDER TO
9. ADJUSTMENT COEFFICIENT: 1.0 COMPLY WITH ALL pPPLICADLE CODES,
10. COMPONENTS & CLADDING WIND PRESSURE ON:
10A: ROOF ZONE: 1) +21.8 / -34.6
2) +21.8 / -60.3
3) +21.8 / -90
1OB: WALL ZONE: 4) +37.8 / -41 � S lO'DbDGj
T I ITC F f 01.T3. T1T Z7,P iti
5) +37.8 / -50.7 ' � iletirf n TOR c
1OC: GARAGE DOOR: 6) N/A n! I I=:". `D By I.1r�Ce
INTERNAL PRESSURE COEFFICIENT: +/- : 0.18 I'I�a�'sirJsT
DF r;I:Pr c.
LOADS: FLOOR 50 PSF >'� �O LNSPECI IO`4 rvu,L ILE, +,I.aI�1.. ao::
ROOF DEAD/LIVE: 15/30 PSF
IMPACT PROTECTION: IMPACT GLASS
CONCRETE WEATHERING RISK: NEGLIGIBLE 1
TERMITE INFESTATION RISK: VERY HEAVY
NOTE: ALL ZONES CALCULATED FOR WORST CASE SCENARIO; (10 S.F. EFFECTIVE WIND AREA)
(DOOR/WINDOW PRESSURES MAY VARY BASED ON SIZE OF DOOR/WINDOW OPENING)
BUILDING DEPARTMENT PRODUCT APPROVAL
PRODUCT
MODEL #
MANUFACTURER
ATTACHMENT METHOD
APPROVAL # /
PRESU� ESIGN
TYPE, SIZE., SPACING & EADET)MENT
EXPIRATION
EVALUATION
AGENCY
PRODUCT DESIGN
PRESSURES
WINDOW
8100 SERIES
VINYL SING. HUNG.
CUSTOM WINDOW
AS PER MANUF. INSTALL.
FL 582 3
FL-5822020
+37.8/-50.7
SYSTEMS
INSTR,
FPA
+67.5/ -67.5
WINDOW
8400 SERIES
CUSTOM WINDOW
AS PER MANUR INSTAI I.
FL 7060.1
+37.8/-50.7
VINYL AWNING
IMPACT
SYSTEMS
INSTR.
07/21/0.1
FpA
+67.5/ -67.5
SLIDING GLASS
570 SERIES
PGT
AS PER MANUR INSTALL.
FL-8208 2
+37.8/ -41
DOOR
IMPACP
INSTR.
+60/ -60
11/11/2016
FPA
FRONT ENTRY
GLAZED FIBERGLASS
THERMA TRU
AS PER MANUF. INSTALL,
FL-10975.1
+38.5 / -41.9
DOOR
INSTR
12/31/2015
FPA
+55/ -55
REAR ENTRY
GLAZED FIBERGLASS
THERMA TRU
AS PER MANUF. INSTALL,
FL-10975.1
+38.5 / -41.9
DOOR
INSTR.
12/31/2015
FPA
+55/ -55
ROOF
GULFLOK
GULF COAST
AS PER MANUR INSTALL.
FL-11651.2
-90
SUPPLY & MANUR
INSTR.
04/12/2024
-116
FPA
SHUTTERS
IMPACT ALUMINUM
FLORIDA
AS PER MANUR INSTALL.
144120.09
+54 / -64
BAHAMA
SHUTTERS INC.
INSTR
03/08/2024
13192.2
+80/ -80
FIBER CEMENT
HARDIE-PLANK
JAMFS HARDIE
AS PER MANUR INSTALL.
INSTR.FPA
01/01/2016
;-53.8SIDING
67.2MULL
BAR
1760 SERIES
CUSTOM WINDOW
INSTALLEDBYMANUF.
FL-9520.01
46.1 / -50
MULL BAR
SYSTEMS
04/10/2016
+80/ -80
FPA
tit
,�� I iI,.Y, p aT gVl€ �.
pp �i I
k
Y
v
T
z
Z
L
U;
i-
z
IL
tf`
I--
z
C)
}
z
z
z
W
T)
Z
O
Q
lv
0
uJ
z
O
0
W
0
Z
}
Z
l7
Z
II_
Li
a.1
0
Z
I-
ce
Q
Iv
qz
W
U
W
z
I-
Q
U
W
1z
w
0
J
U
o
W
q
CV
b
O
LO
>
CV
`o
00
0
rn
�V)
Z
y
N
ram.
v
C
O
Q
D
4
D
tJ
c~n
V
N
W-)
W
r
Lu
(N
c
to
(- I
,a)
�
W
O
�
0
U
0�
0-0
7
N
c
j
1�
0
F+�V
z
Z
z
�1
z
J
SITE PLAN
PKOJECT
DATA
PROJECT NO.: SNYDER l
DRAWN BY: LV
DATE: 9.29.15
REVISIONS:
zi 10/29/15 PER BUILD. DEPT
A3 12/16/15 PER ARCH.
SHEET NO.
SHEATHING NAILING SCHEDULE
ITEM
NAIL SIZE
EDGE
FIELD
NOTES
SPACING
SPACING
e" CDX ROOF
ZONE 1, 2, & 3 (8d ROUND
4" O.C.
6" O.C.
GLUE ALL PLYWOOD WITHIN
TRUSS CONNECTION SCHEDULE
TYPICAL CONNECTION
NOTES:
ALL MEMBERS ARE ANCHORED TO CONCRETE BEAM WITH SIMPSON HHETA20
UNLESS NOTED OTHERWISE. ALL MEMBERS ARE ANCHORED TO FRAME WALLS WITH
(2) SIMPSON HTS20 UNLESS NOTED OTHERWISE ON LAYOUT.
TRUSS ID
SIMPSON
CONNECTOR ID
FASTENERS
MAX ALLOWED
UPLIFT
NOTES
TRUSS TO FRAME WALL
HTS20
20-10d
1450 (EACH)
GIRDER TO FRAME WALL
HTS20
20-I0d
1450 (EACH)
(2) EACH TRUSS END
NOTES:
-TRUSS MANUFACTURER IS RESPONSIBLE FOR FINAL LAYOUT, SPANS, & ALL TRUSS & HEADER ENGINEERING.
-TRUSS MANUFACTURER TO INDICATE UPLIFT REACTIONS @ TRUSS/GIRDER ENDS & PROVIDE HANGER
CALLOUTS FOR TRUSS TO GIRDER & GIRDER TO GIRDER CONNECTIONS
-SIMPSON CONNECTORS SHALL BE ATTACHED PER MANUFACTURERS STANDARDS. VERIFY WITH
MANUFACTURER PRIOR TO INSTALLATION.
-INSTALL MOISTURE BARRIER BETWEEN CONCRETE AND ALL NON PRESSURE -TREATED WOOD FRAMING.
-SUBSTITUTION OF ANCHORAGE HARDWARE W/ EQUAL OR GREATER VALUES IS PERMITTED WITH APPROVAL
FROM ARCHITECT. ARCHITECT ASSUMES NO RESPONSIBILITY FOR SUBSTITUTIONS WHICH DO NOT MEET THE
LOAD REQUIREMENTS.
BEARING HEADER SCHEDULE
HDR. SIZE
SPECIES
NAILING
OPENING
JACKS
FULL STUDS
NOTES
(2) 2x6
S.P.F.
STAGGERED
UP TO 3' 11"
(1)
(1)
16d @ 12" O.C.
(2) 2x8
HEM/FIR
STAGGERED
4' 0"-6' 0"
(1)
(1)
16d @ 12" O.C.
(2) 2x10
HEM/FIR.
STAGGERED
6' 1 "-8' 6"
(2)
(1)
16d @ 12" O.C.
(2) 2x12
HEM/FIR
STAGGERED
8' 7"-16' 0"
(2)
(2)
16d @ 8" O.C.
NON -BEARING HEADER SCHEDULE
HDR SIZE
SPECIES
NAILING
OPENING
JACKS
FULL STUDS
NOTES
(2) 2x4
S.P.F.
STAGGERED
UP TO 3' 11"
(1)
(1)
16d @ 12" O.C.
(2) 2x6
S.P.F.
STAGGERED
4' 0"-9' 8"
(1)
(1)
16d @ 12" O.C.
(2) 2x10
HEM/FIR
STAGGERED
6' 1"-8' 6"
(2)
(1)
16d @ 12" O.C.
(2) 2x12
HEM/FIR.
STAGGERED
8' 7"-16' 0"
(2)
(2)
16d @ 8" O.C.
1 ROOF PLAN 2
A3 1 /4"=1'-O" (1 /8"=1'0" HALF SIZE) (A3
PLUMBING LEGEND
VENT PIPING
STUDCR VENT (SV )
} RODF VENT
PLUMBING NOTES
A. ALL WORK SHALL COMPLY WITH 2O14
FLORIDA PLUMBING CODE, 2014 FLORIDA
GAS CODE, AND ANY OTHER APPLICABLE
CODES.
B. PLUMBING PIPING & VALVES:
—COPPER TYPE "K" PIPING AND FITTING
BELOW SLAB.
—COPPER TYPE 1" PIPING AND FITTINGS
ABOVE SLAB.
—LEAD FREE SOLDERED JOINTS.
—SCHEDULE 40 PVC SANITARY SEWER &
VENTS.
C. VENT TO REAR OF STRUCTURE
D. CONTRACTOR TO VERIFY ALL PIPE
SIZES/SPECS PER EQUIPMENT AND
APPLICABLE CODE.
E. CONNECTION TO EQUIPMENT SHALL BE
VERIFIED WITH MANUF.'S CERTIFIED
DRAWINGS.
F. BEFORE FABRICATION, VERIFY AND
COORDINATE ALL DIMENSIONS IN FIELD.
G. ALL EQUIPMENT SHALL BE SUPPORTED AS
REQUIRED TO PROVIDE A VIBRATION
FREE, RIGID INSTALLATION.
H. PROVIDE WATER HAMMER ARRESTORS AT
EACH BRANCH LINE.
2"SINK V
DISP. &
DISHWAS
PLUMBING RISER
1/4"=1'-0" (1/8"1'0" HALF SIZE
SANITARY
SEWER
H WR.
a
2�8 @ 24" Q.C.
ROOF FRAMING PLAN
1/4'"=1'-0" (1/8"=1'0" HALF SIZE
O
Q
lLJ
tv
cG1
Z
O _
U �
Q � �
o �
oC z
O
UJ
O
z
}
Z
Q
O
z .G..__
O
z
0
o_
LLJ
<De
QLLJ
f
uJ
L
KOO /KOO
FRAMING AMING PLAN`
SCh�DUL�S
Ants
C,
..1 Q
PLUMF)ING
'n' b 5 "ir
1 °'ate R15ER
6
Y ' `1 'n'�1 Q PROJECT NO.: SNYDER I
Z DRAWN BY: LV
0
DATE 9.29,15
Q REVISIONS
A 12/16/15 PERARCH.
U
# P6N o- 5, SHEET N0,
Z
A3
J
15 0" (T.O.P.)
14 3" (HEAD HT.)
SIMPSON HTS20
(EACH RAFTER)
lx2 P.T. DRIP ON
lx6 FIBER
CEMENT FASCIA
FIBER CEMENT
SOFFIT -I" x 4" FIBER CEMENT FRIEZE
FIBER CEMENT SIDING ON
TYVEK OR EQ, HOUSE WRAP
ON !�" CDX PLYWOOD
SHEATHING.
SIMPSON H10 EACH 2x6.
STANDING SEAM METAL ROOF ON
PEEL-N-STICK UNDERLAYMENT [IN g"
PLYWOOD SHEATHING
SPRAY FOAM-
/ T.
(Owl
P. )
INSUL-ATIDN
(xR-20 MIND
2x6 @ 24" GC,-
g 0 ( HEAD.
HT.)
SIMPSON HTS20 (IEACH)-
(& BOTTOM OF
n
BEAM)
35" GUTTER DN
"P.T.1x2
7 0
(T.O.P.)
A72�1
DRIP DN
1x6 FIBER
(STUDIO/BEDROOMTUDIO/BEDROOM
2)
CEMENT FASCIA
FIBER CEMENT SOFFIT
—
I' 1" x 4" FIBER CEMENT F ZE —
EIBER CEMENT SIDING ON
TYVEK OR EQ HOUSE WRAP
❑N 15" CDX PLYWOOD
SHEATHING
0' 7, 25" (T. 0. F. F. )
(*BEYOND
0' 0" ( T. 0. F. F. ) O
wl
7.2
BASE FLOOD ELEVATION
AE 6
EXISTING GRADE
3.45-4.5
SIMPSON PA51 HOLDDOWN
STRAPS @ 32" O.C.
STUCCO FINIS
FLOOD VENTS (IN
LOCATIONS AS SHOWN ON
FOUNDATION PLAN)
FINISHED GRADE
STANDING SEAM METAL ROOF ON
PEEL-N-STICK UNDERLAYMENT ON g"
PLYWOOD SHEATHING.
SPRAY FRAM
INSULATION
(xR-20 MIN)
12
4
i 2Q.oG
2xg @
SIMPSON LSSU28 HANGER
(A EACH RAFTER)
R-19 MIN. INSULATION
C�
C1J
-D 264O.Cr 2u6 STU OFT
SIMPSON H8 EACH STUD
-a" DIA. x 7" LAG SCREWS @
32" O.C.
4" T&G PLYWOOD SUBFLOOR
(GLUED & SCREWED)
2x10 FLOOR JOISTS @ 16" D.C. (ATTACH
W/ SIMPSON LUS210 EACH END)
(3) 2x10 BEAM W/ (2) LAYERS
PLYWOOD (ATTACH W/ SIMPSON
MGU562-SDS-EACH END & ATTACH TO
EACH SUPPORT COLUMN W/ SIMPSON
H6)
5/8" DRYWALL (CEILINGS)
IMPSON H8 EACH STUD
2x6 COLLAR TIES @ 24"DC
(10-101) NAILS EACH END)
EE TYPICAL RAILING DETAIL
SIMPSON H8 EACH STUD
4" DIA. x 7" LAG SCREWS @
32" 11 C
CEILING BEYOND BEAM (9'0" HT.)
(3) 2x10 BEAM W/ (2) LAYERS"
PLYWOOD (ATTACH W/ SIMPSON
MGU562-SDS-EACH END & ATTACH TO
EACH SUPPORT COLUMN W/ SIMPSON H6
(3) 2x10 BEAM W/ (2) LAYERS �"
PLYWOOD (ATTACH W/ SIMPSON
MGU562-SDS-EACH END & ATTACH TO
EACH SUPPORT COLUMN W/ SIMPSON HG
STANDING SEAM METAL ROOF ON
PEEL-N-STICK UNDERLAYMENT ON"
CDX PLYWOOD SHEATHING DN
PRE-ENGINEERED WOOD RODE
TRUSSES.
STANDING SEAM METAL REEF ON
PEEL-N-STICK UNDERLAYMENT ON 5"
PLYWOOD SHEATHING ON
PRE-ENGINEERED WOOD ROOF
TRUSSES.
� 1x6 T&G PORCH CEILING
(2) 2 x 8 BOLTED THROUGH
NOTCHED 6x6 POST W/ (2) 5"-
GALV, LAG SCREWS, (ADD
ADDITIONAL 2x8 & 2 LAYERS
° PLYWOOD BETWEEN
COLUMNS)
ATTACH BEAM TO SOLID WALL
FRAMING W/ SIMPSON LUS28-2Z OR
APPR. EQEACH END.
i
1/2" DRYWALL C� A
I I C`7
co O
PROVIDE BLOCKIYdG 2 __L Si-EATHINCI P=J.E_ -7GES
P.T. 6x6 POST
- R-19 MIN. INSULATION
2X4 or 2XG STUDS WRAP COLUMN W/ 4"
16" O.C. FIBER CEMENT TRIM
I
-SIMPSON H8 EACH STUD
a" (3) 2x12 BEAM
4 DIA, x 7" LAG SCREWS @
32" O.C. & 6" FROM ALL
CORNERS
3„ 2x12 FLOOR JOISTS @ 16" ❑,C.(ATTACH P.T. jx6 DECKING SCREWED DOWN
a T&G PLYWOOD SUBFLOOR W/ SIMPSON LUS210 EACH END) O P.T. 2x8'S @ 16" OC, - ATTACH
GLUED & SCREWED) W/ SIMPSON LUS28Z, LUS28-2Z OR
71�„ [(T�wPPR. EQ EACH END.
VTT
�T s�oae
PT2x SILL PLATE
8" CMU W/ 1 #5 VERT.
REBAR @ 4'0" O.C. & 1 45
BAR CENT, IN TOP COARSE.
-FILL ALL CELLS SOLID
WPILING
18" DEEP x 24' WIDE
CONC, SPREAD FTG/GRADE
BM W/ 3 #5 BARS TOPBOTTOM CONT.
3" CLR.
SEE FOUNDATION PLAN FOR
PILING LOCATIONS, SEE
PILING NOTES SHEET Al FOR
SPECIFICATIONS &
PILING DETAIL 4:A6
'PT. 2x8 LEDGER ATTACHED W/
d
2-�'O GALV, THROUGH BOLTS @
R-30 BATT INSULATION
°
32' N.C.
FASTEN BEAM TO CMU
8"xl6"
CMU PIER W/ 2 #5
PIER W/ SIMPSON PA51
SIMPSON STRONG
VERT.
°
REBAR. -FILL ALL
STRAP 2" CONCRETE "MUD MAT" SLAB
TIE 6x6 UPLIFT
CELLS SOLID
OPENED TO CRAWL SPACE
POST BASE
— —
OPENINGS
(ABU66Z DR EQJ
a
—
a
--
a
48"x48"x16" DEEP
FTG W/
°
4 #5 REBAR EACH
WAY
�
-
a
a
4
�.
°
°a
I
A
3" CLR.
`\ 3" CLR.
a
SEE FOUNDATION
PLAN FOR
PILING
LOCATIONS, SEE
PILING
NOTES SHEET Al FOR
PILING
SPECIFICATIONS &
DTI TKIC
i FC ATI I IL
1 BUILDING SECTION
510-
SIMPSON H5 CLIP
7vz EACH
LINT , FLASHING ON
P.T. lx2 DRIP
1"x6" FIBER CEMENT FASCIA
2"x4" SUB FASCIA
FIBER CEMENT SOFFIT
10' 0" (T.O.B.)
—FIBER CEMENT SIDING ON
TYVEK OR EQ. HOUSE WRAP
ON R" 5-PLY APA RATED
PLYWOOD SHEATHING,
WRAP BEAM W/ FIBER
CEMENT TRIM
X 18" FIBER CEMENT
TRIM
SIMPSON STRONG
TIE: 6x6 UPLIFT
POST BASE
(ABU66Z OR EQ)
a" X 111' FIBER
CEMENT TRIM
(J) P.T. 2x8 BEAM
(P) SIMPSON LCE4Z EACH POST
P,T, 6x6 POST
RADE
18" DIAMETER X 24" DEEP
FOOTING W/ 4 #5 BARS
wN
i
r
a
'I• �{ `t'�i Y�.
U)
z
0
U E
z 0
OU rT, U
w
� CV Q
W 0 c b
o (�: "0
U M � QQ 4 #t
F�1 iI ? _
Q �� R � Z
4>,'` r U Q
U �' Q
ld U E
V L"' 0 CW�
`-� T_: 00 <C
i/ c C�
Z v) Cxl .0
o W®� j
0.' U Cs4
ZTi
Z C) 0
} >
Z
Q vy U
z
Z �
0
T) L
ld _.
_0
Q
J
Q
__J
-
u�J
z
u {{ii
O uj
Lj
o Z
Z F�—H
ld t -t
Z
z
z
} �--
Z
Q
Li LLJ
0 v
U
Z
UUILDING
z 5E.CTION
Li
IN
R
a PROJECT NO.: SNYDERI
Z DRAWN BY: LV
DATE: 9.29.15
QREVISIONS
L 12/16/15 PERARCH.
J
LJ
SHEET NO.
Vb
J)
z
i
10
A-5
LJ
a
g 18' DEEP x 24' WIDE
CONC SPREAD FTC/GRADE
BM W/ 3 45 BARS TOP &
BOTTOM CENT.
14'x20'0' LONG AUGER CAST
PILING W/ 6-#6 BARS & #3
TIES @ 244 ❑,C (SEE
FOUNDATION PLAN FOR
LOCATIONS & PILING
SPECIFICATIONS SHEET A1)
74), TYP. PILING DETAIL
A6 3/4"=1'-0"
0
N
`--WALL FRAMING (KSEE
WALL SECTION) -- --
1 TYP. OPENING STRAPPING_ DETAIL
A6 3/4"=1'-0"
B'xl6' CMU PIER W/ 2
#5 VERT. REBAR. -FILL
3 1/El ALL CELLS SOLID
ZD
POWDER -COATED —�
ALUMINUM RAILING
SYSTEM INSTALLED
PER MANUFACTURER'S
SPECIFICATI➢N,
x
2 EXTERIOR RAILING DETAIL
METAL BAi llc=Mo lwe 7VI r
FINISH l
OWNER)
WOOD HANDRAIL
(KSTYLE FINISH
SELECTED BY ❑�
BALLUSTERS TO PREVENT
PASSAGE OF 4" SPHERE,
3 LOFT GUARDRAIL DETAIL
3/4"=1'-0" - —
34' T&G PLYWOOD
SUBFLOOR; GLUED &
�! NAILED
2x12 FLOOR JOISTS @
16" ❑.C. (ATTACH W/
SIMPSON LUS210 EACH <
END)
\ (3) 2x12 BEAM
PT2x8 SILL PLATE
FASTEN BEAM TO CMU
PIER W/ SIMPSON PA51
STRAP
48'x4P Y_6' DEEP FTC w:
4 a
4 Is5 REBAR EACH WAY - e
ea qa
d
a
n 3"CLR. 3"CLR.
44'
4 SEE FOUNDATION PLAN FOR PILL
LOCATIONS. SEE PILING NOTES
SHEET Al FOR PILING
SPECIFICATIONS & PILING DETAI
4 AG
c�
5 INTERIOR PIER DETAIL
--- — -- - _
A 3/4"=1'-0"
P.T. 1x6
(STAGGERED)
T. 2x2
FRAME ATTACHED
TO 6X6
POSTS
INSECT
SCREEN
(INSIDE
FACE)
SHIPLAP SKIRTING DETAIL
A6 3/4"—V—O"
STANDING SEAM METAL ROOF ❑N
PEEL-N-STICK UNDERLAYMENT ON
PLYWOOD SHEATHING.
SPRAY FOAM
INSULATION
(KR-20 MIN.)
PRE-ENG. ROOF TRUSSES
SIMPSON HTS20 (EACH TRUSS) 4r
3j" GUTTER ON PJT 1 0" II�
lx2 DRIP ON lx6 72"
FIBER CEMENT FASCIA
9' 0" (T.O.P.)
3
FIBER CEMENT SOFFIT-
V x 4" FIBER CEMENT FRIEZE
FIBER CEMENT SIDING ON
TYVEK OR EQ. HOUSE WRAP
ON CDX PLYWOOD
SHEATHING
SIMPSON PA51 HOLDDOWN
STRAPS @ 32' D.C.
0'0"&0'7.25 (T.0.F.F.)
7.2&7.8
STUCCO FINISH —
BASE FLOOD ELEVATION _
AE 6 FLOOD VENTS (IN —
LOCATIONS AS SHOWN ON
FOUNDATION PLAN)
EXISTING GRADE
3.45-4.5
FINISHED
0
5/8' DRYWALL (CEILINGS)
SIMSPSON H8 EACH STUD
1/2' DRYWALL
-PROVIDE BLOCKING @ ALL
SHEATHING PANEL EDGES
R-19 MIN. INSULATION
2X4 or 2XG STUDS
16' ❑.C.
-SIMPSON H8 EACH STUD
J" DIA. x 7" LAG SCREWS @
32' D.C. & 6' FROM ALL
CORNERS
' T&G PLYWOOD SUBFLOOR
(GLUED & SCREWED)
PT2x8 SILL PLATE
8" CMU W/ 1 45 VERT,
REBAR @ 4'0' O.C. & 1 #5
BAR CONT,IN TOP COARSE,
-FILL. ALL CELLS SOLID
o A e 18" DEEP x 24' WIDE
CONC SPREAD FTC/GRADE
w ° ° BM W/ 3 #5 BARS TOP &
4 BOTTOM CONT.
a
3" CLR.
20, SEE FOUNDATION PLAN FOR
- -- PILING LOCATIONS, SEE
PILING NOTES SHEET Al FOR
PILING SPECIFICATIONS &
PILING DETAIL 4 AG
EXTEND 2x6 24' MIN. BEYOND EDGE OF ROOF
TRUSS & ATTACH W/ (10 IOD NAILS EACH.
STANDING SEAM METAL ROOF ON
PEEL—N—STICK UNDERLAYMENT ON g
PLYWOOD SHEATHING.
2x6 @ 24' ❑.C.
SIMPSON HTS20 (EACH)
3j' GUTTER ON 71.
P.T. lx2 DRIP ON
lx6 FIBER
CEMENT FASCIA
FIBER CEMENT SIDING
ON TYVEK OR EQ, HOUSE
WRAP ON J' OSB
SHEATHING.
WRAP BEAM & COLUMN-
W/ FIBER CEMENT TRIM
" X 74" FIBER CEMENT --
TRIM
P.T, 6x6 POST
SIMPSON STRONG
TIE: 6x6 UPLIFT
POST BASE
(ABU66Z OR EQ.)
4" X 1114" FIBER
CEMENT TRIM
(3) P.T, 2x8 BEAM
(2) SIMPSON LCE4Z EACH POST
P.T. 6x6 POST
FI
18" DIAMETER X 24" DEEP
FOOTING W/ 4 #5 BARS
L-ATTACH BEAM TO SOLID WALL
FRAMING W/ SIMPSON LUS28-2Z OR
APPR. EQ. EACH END.
lx6 T&G CEILING
P.T. qx6 DECKING
SCREWED DOWN TO P.T.
2x8'S @ 16" ❑,C. -
ATTACH W/ SIMPSON
LUS28Z, LUS28-2Z OR
APPR EQ, EACH END
RT, 2x8 LEDGER
ATTACHED W/ 2-8"0
GALV. THROUGH BOLTS
@ 32" ❑.0
SIMPSON STRONG
TIE: 6x6 UPLIFT
POST BASE
(413U66Z OR ED.)
e
TYP. WALL SECTION g REAR PORCH SECTION
3/4"=1'-0" A6 3/4' =1'—O"
1 4
l
k$ ,
1$y�
H
U
E
O
w
O
N
2
C
LL
Lf)
>
L
nl
I`�.
`L)
U)
�D
C,
00
O
4:k
c/7
C\I
u
Z
>
Q
+—.
Q
1
1�
V)
D
C
;;
�
Lj
( W
C�
��p
JWN�o
V)
N
[�
3
r�,
r.
V)
O
U
�Q
7
G=
SECTICON5
DETAIL_5
PROJECT NO,: SNYDER I
DRAWN BY: LY
DATE: 9.29.15
REVISIONS:
0 12/16/15 PERARCI-I.
SHEET NG.