Loading...
HomeMy WebLinkAboutCertification For Design Load CompliancePlanning & Development Services Department Building & Code Regulations Division ti " ^'-i' 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1577 Certification for Design Load Compliance Th Edition Project Name: REBUILD FLORIDA ID-004995—COE - 4BR Project Address: 3005 Cortez Blvd., Fort Pierce, FL 33404 Permit #: Occupancy Type: SF Residential Construction Type: Wood Framed INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • If submitting hard copy, submit (2) copies with all pertinent information. St Lucie Fire District requires a digitally signed electronic version. • If submitting electronically, form should be uploaded into Bluebeam. Separate submission to Fire is still required • All digital files must be in an unlocked Portable Document Format (PDF) version * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the plan reviewer. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida RESIDENTIAL Code 7th Edition using ASCE 7-16 2. Structure Designed as (check one): X Enclosed Partially Enclosed Open 3. Risk Category: 1 II III IV Exposure Category: X B C D 4. Design Wind Velocity 180 mph 139 ASD LRFD End Zone Width: 7.7 ft S. Mean Roof Height 13.25 ft Roof Pitch: 5 :12 Parapet: ft 6. Components & Cladding Design Pressures Used: Zone 4: 33.4/-36.3Zone 5: 33.4/-43.6 Garage: N/A 6a. Roofs Maximum +/- pressures: +26.1 psf - 64.6 psf Or define individual zones on the plans 7. Design Loads: Floor:40 PSF Roof-Dead:15 PSF Roof-Live:20 Balcony+/- PSF Dock: PSF Deck: PSF Stairs:40 PSF Fence: PSF Railings:50 PSF 8. Were Shear Walls Considered For Structure? X Yes Not Applicable Please Explain: 9. Is a Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2000 PSF Soil Test Reports Submitted? Yes No Assumed DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the current Florida Building Code as adopted. Digitally 21.08.0916:gned yBeau -ouoo Beau Tate, P.E., 400179E7834E6DC3020D8432F87F1C85, IdenTrust 'Date: 2021.OB.09 18:42:30 -05'00 Signature, Date, andSeal Print Name Cert # & Co. CertofAuthorization Royal Engineers & Consultants Revised 3/25/2021 Company Name & Address 1 rfi +i