Certification for Design Load Compliance
Th Edition
Project Name: REBUILD FLORIDA ID-004995—COE - 4BR
Project Address: 3005 Cortez Blvd., Fort Pierce, FL 33404
Permit #: Occupancy Type: SF Residential Construction Type: Wood Framed
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• If submitting hard copy, submit (2) copies with all pertinent information. St Lucie Fire District requires a digitally
signed electronic version.
• If submitting electronically, form should be uploaded into Bluebeam. Separate submission to Fire is still required
• All digital files must be in an unlocked Portable Document Format (PDF) version
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the plan reviewer. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida RESIDENTIAL Code 7th Edition using ASCE 7-16
2. Structure Designed as (check one): X Enclosed Partially Enclosed Open
3. Risk Category: 1 II III IV Exposure Category: X B C D
4. Design Wind Velocity 180 mph 139 ASD LRFD End Zone Width: 7.7 ft
S. Mean Roof Height 13.25 ft Roof Pitch: 5 :12 Parapet: ft
6. Components & Cladding Design Pressures Used:
Zone 4: 33.4/-36.3Zone 5: 33.4/-43.6 Garage: N/A
6a. Roofs
Maximum +/- pressures: +26.1 psf - 64.6 psf Or define individual zones on the plans
7. Design Loads: Floor:40 PSF Roof-Dead:15 PSF Roof-Live:20 Balcony+/- PSF
Dock: PSF Deck: PSF Stairs:40 PSF Fence: PSF Railings:50 PSF
8. Were Shear Walls Considered For Structure? X Yes Not Applicable Please Explain:
9. Is a Continuous Load Path Provided? X Yes Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: 2000 PSF Soil Test Reports Submitted? Yes No Assumed
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the current Florida Building Code as adopted.
Digitally 21.08.0916:gned yBeau -ouoo Beau Tate, P.E., 400179E7834E6DC3020D8432F87F1C85, IdenTrust
'Date: 2021.OB.09 18:42:30 -05'00
Signature, Date, andSeal
Print Name Cert # & Co. CertofAuthorization
Royal Engineers & Consultants
Revised 3/25/2021 Company Name & Address 1 rfi +i