Loading...
HomeMy WebLinkAboutSite Plan & DetailsRECEIVED �., p.L�ai� bG04117ty GENERAL NOTES: 1. TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMITICIDES, INCLUDING SOIL APPLIED PESTICIDES, BAITING SYSTEMS, AND PESTICIDES APPLIED TO WOOD, OR OTHER APPROVED METHODS OF TERMITE PROTECTION LABELED FOR USE AS A PREVENTATIVE TREATMENT TO NEW CONSTRUCTION. SEE 2020 FLORIDA RESIDENTIAL CODE SECTION 202, "REGISTERED TERMITICIDE." UPON COMPLETION OF THE APPLICATION OF THE TERMITE PROTECTIVE TREATMENT, A CERTIFICATE OF COMPLIANCE SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY THE LICENSED PEST CONTROL COMPANY THAT CONTAINS THE FOLLOWING STATEMENT: "THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. TREATMENT IS IN ACCORDANCE WITH RULES AND LAWS ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES." 2. ALL WORK SHALL MEET APPLICABLE REQUIREMENTS OF THE 2020 FLORIDA BUILDING CODE, BUILDING, 7TH EDITION AND 2020 FLORIDA BUILDING CODE, RESIDENTIAL 7TH EDITION. 3. APPLIANCES SHALL BE ENERGY STAR LABELED - CLOTHES WASHERS, DISHWASHERS, REFRIGERATORS AND CLOTHES DRYERS. SUPPLY HOSES TO WATER USING FIXTURES AND APPLIANCES MUST BE ARMORED, PEX OR METAL (EXCEPT COPPER) 4. SLOPE ALL CONCRETE PAVING AWAY FROM BUILDING AT 1% MINIMUM. SLOPE ALL CONCRETE WALKS AWAY FROM BUILDING AT 2% MINIMUM. 5. SLOPE ALL FINAL GRADING AWAY FROM BUILDING TO ENSURE POSITIVE DRAINAGE. 6. LAY NEW SOD TO COVER ALL AREAS OF YARD DISTURBED BY CONSTRUCTION ACTIVITIES. SOD MUST BE BAHIA, ZOYSIA, OR BERMUDA 7. CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS AND NOTIFY ARCHITECT OF ANY DISCREPANCIES WITH PLANS AND AS -BUILT CONDITIONS PRIOR TO PROCEEDING WITH THE WORK. 8. DO NOT SCALE DRAWINGS; DIMENSIONS GOVERN. LARGE SCALE DETAILS GOVERN OVER SMALL SCALE DETAILS. NOTIFY ARCHITECT WITH ANY DISCREPANCIES OVER DIMENSIONS. 9. ALL DIMENSIONS ARE TO THE FACE OF THE STUDS (ROUGH) UNLESS OTHERWISE NOTED. 10. THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS, INSPECTION FEES, AND DEPOSITS REQUIRED FOR THE INSTALLATION OF ALL WORK. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO CALL FOR LOCAL INSPECTIONS AND OBTAIN APPROVAL FROM THE STATE FIRE MARHSAL IF REQUIRED. 11. ALL CONSTRUCTION WORK SHALL BE IN COMPLIANCE WITH ALL LOCAL CITY, COUNTY, STATE OF FLORIDA AND FEDERAL CODES. THE CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS, AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY BEARING PERFORMANCE OF THE WORK. 12. VERIFY ROUGH OPENING SIZES WITH DOOR AND WINDOW MANUFACTURERS BEFORE CONSTRUCTION IS TO BEGIN. 13. SAFETY GLAZING SHALL BE PROVIDED AT HAZARDOUS LOCATIONS AS PER SECTION R308.4 OF THE FRC 2020, 14. COMBINATION SMOKE /CARBON MONOXIDE DETECTORS SHALL BE PROVIDED IN AND OUTSIDE ALL SLEEPING AREAS. 15. EACH SLEEPING ROOM MUST HAVE AT LEAST ONE OPERABLE WINDOW OR EXTERIOR DOOR APPROVED FOR EMERGENCY EGRESS OR RESCUE. UNIT MUST BE OPERABLE FROM INSIDE TO FULL CLEAR OPENING OF 5.7 SQUARE FEET, WITH SILL HEIGHT NO MORE THAN 44 INCHES ABOVE THE FLOOR, MINIMUM NET CLEAR OPENING HEIGHT OF 24 INCHES, AND MINIMUM NET CLEAR OPENING WIDTH OF 20 INCHES. 16. EXTERIOR WALLS WITH A FIRE SEPARATION DISTANCE LESS THAN T-0" FEET SHALL HAVE 1 HOUR PROTECTION OF 5/8" GYP BOARD AT BOTH SIDES OF THE WALL. 17. OVERHANG PROJECTIONS WITH A FIRE SEPARATION DISTANCE LESS THAN T-0" (FEET) SHALL BE PROVIDED WITH 5/8" GYP. BOARD UNDERSIDE FOR 1-HOUR PROTECTION. 18. ALL "GLASS OPENINGS" SHALL BE IMPACT RESISTANT GLAZING (COMPLY WITH REQUIREMENTS OF THE LARGE MISSILE TEST OF ASTM 1996 AND OF ASTME 1886 FASTENED IN ACCORDANCE WITH TABLE R301.2.1.2 OF FRC 2020. 19. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY SAFETY APPARATUS REQUIRED TO ENSURE THE HEALTH AND WELFARE OF THE GENERAL PUBLIC, THE OWNERS, AND ANY WORKERS. 20. THE CONTRACTOR SHALL HAVE THE WORK SITE CLEANED ON A DAILY BASIS. THE DISPOSAL OF ANY WASTE SHALL BE OFF SITE AND IN A MANNER PRESCRIBED UNDER THE LAW. 21. CONTRACT DRAWINGS AND SPECIFICATIONS REPRESENT FINISHED STRUCTURE. THEY DO NOT INDICATE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT STRUCTURE AND PERSONNEL DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE BUT NOT BE LIMITED TO BRACING, SHORING OF LOADS DUE TO CONSTRUCTION EQUIPMENT, EXCAVATION PROTECTIONS, SCAFFOLDING, JOB SITE SAFETY, ETC. OBSERVATION VISITS TO THE SITE BY ARCHITECT, OWNER, OR ENGINEER SHALL NOT INCLUDE INSPECTIONS OF ABOVE ITEMS. 22. IT IS RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE VARIOUS TRADES ON BUILDING TO ALLOW SUFFICIENT ROOM FOR ALL EQUIPMENT. 23. CONTRACTOR TO COORDINATE ALL UTILITIES INSTALLATION AND CONNECTION WITH LOCAL UTILITY COMPANY. 24. THE CONTRACTOR SHALL PROVIDE FOR POSITIVE DRAINAGE AROUND THE BUILDING INCLUDING ANY TEMPORARY MEASURES DURING THE CONSTRUCTION SO AS TO ENSURE NO WATER DAMAGE TO THE BUILDING. 25. ALL REMOVED TOPSOIL SHALL BE STORED AND USED FOR FINISH GRADING. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL OF ALL DEBRIS MATERIAL PRIOR TO FINISH GRADING. 26, CONTRACTOR SHALL COORDINATE & INSTALL WOOD BLOCKING IN FRAMING AS NEEDED TO SUPPORT ANY ITEMS MOUNTED TO THE WALLS. 27. ALL PENETRATIONS THROUGH FIRE RATED WALLS ARE TO BE SEALED WITH CODE APPROVED FIRESTOPPING MATERIAL. 28. THE CONTRACTOR SHALL VERIFY THE MIN. F.F. ELEV. WITH THE CITY/PARISH FEMA ELEVATION AND BENCHMARK CERTIFICATE. 29. ALL DRIVEWAY AND SIDEWALKS SHALL MEET LOCAL DEPARTMENT OF PUBLIC WORKS STANDARD DETAILS IF APPLICABLE. 30. CONTRACTOR SHALL PROVIDE COLOR SCHEMES FOR ALL CABINETS, COUNTERTOPS, FLOORING AND EXTERIOR MATERIALS IN A NEUTRAL COLOR PALETTE. ALL INTERIOR WALLS, CEILINGS AND TRIM MUST BE WHITE. 31. CONTRACTOR SHALL PROVIDE ALL PLUMBING FIXTURES, ELECTRICAL FIXTURES, DOOR HARDWARE, BATHROOM HARDWARE, AND BATHROOM ACCESSORIES IN A CONSISTENT MATERIAL FINISH. 32. CONTRACTOR SHALL PROVIDE CLEAN OUT LOCATIONS, TIE-IN LOCATIONS, AND WATER AND SEWER LINE LOCATIONS ON SITE TO PERMIT DEPARTMENT FOR REVIEW. 33. CONTRACTOR SHALL PROVIDE ELECTRICAL LOAD CALCULATIONS AND ANY ADDITIONAL ELECTRICAL INFORMATION REQUESTED BY PERMIT DEPARTMENT NOT SHOWN IN DRAWINGS. on -to] I I I platcNi- 1. W. 3005 CORTEZ BLVD, FORT PIERCE, FL 34981 FOR CONSTRUCTION PROJECT INF OCCUPANCY: BUILDING CODE: PERMIT TYPE: ORMATION: SINGLE FAMILY RESIDENTIAL 2020 FLORIDA BUILDING CODE, BUILDING, 7TH EDITION 2020 FLORIDA BUILDING CODE, RESIDENTIAL, 7TH EDITION NEW CONSTRUCTION FFE INFORMATION: FLOOD ZONE: X FEMA BASE FLOOD ELEVATION: N/A HIGHEST ADJACENT GRADE: 16.80' NAVD88 CROWN OF THE ROAD: 18.36' NAVD88 PROPOSED FFE.: 20.30' NAVD88 ZONING INFORMATION: ZONING CLASSIFICATION: RS-4 USE: DWELLING, SINGLE-FAMILY MINIMUM LOT AREA: SINGLE FAMILY: 10,000 SF/DU MINIMUM LOT WIDTH: SINGLE FAMILY: 75' MAX. BUILDING HEIGHT: SINGLE FAMILY: 35' FRONT YD MIN. REQ: SINGLE FAMILY: 25' INT SIDE YD REQ: SINGLE FAMILY: 7.5' CORNER SIDE YD MIN. REQ: SINGLE FAMILY: 20' REAR YD MIN. REQ: SINGLE FAMILY: 15' BUILDING INFORMATION: FIRST FLOOR: 1992 SF FRONT PORCH: 187 SF REAR PORCH: 178 SF BUILDING HEIGHT: 17' - 0 7/8" CONDITIONED AREA VOLUME: 14,464 CF INDEX OF DRAWINGS G-1 TITLE SHEET C-1 I SITE PLAN & DETAILS A-1 JARCHITECTURAL PLANS A-2 ELEVATIONS A-3 DETAILS A-4 VINYL SIDING DETAILS RAISED HOUSE E-1 ELECTRICAL PLAN M-1 MECHANICAL M-2 MECHANICAL M-3 MECHANICAL P-1 PLUMBING PLAN S-1 STRUCTURAL NOTES S-2 FOUNDATION PLANS & DETAILS S-3 FOUNDATION DETAILS S-4 FRAMING PLANS & DETAILS S-5 FRAMING PLANS & DETAILS S-6 FRAMING DETAILS S-7 DETAILS A.SM- EC q 3 wm Lllvd vI[y1011wa &UllN .Ww, A" to Y N t0 ❑ N N N 0 U ❑ F- z w 0 U Of w EL 0 z <M J W U) Z z O Q r Y (� O r, C W LU J w LL V) N z_ t7 z Q z CD w rn z w , Ill w0N o O °N' S w v in z ry fn d Cn Q 00-0 Cr W 0 0 ❑M G J J J LL m N W Lo J_ �w O D LU Oa O m UH ' W Lo o� O LLO Project Number 2019-15 Date 11/23/2021 Drawn By SM Checked By IP FOR CONSTRUCTION G®1 RECtxiVED LUG'e'UUnty Permitting PROPOSED NEW SINGLE-FAMILY RESIDENCE FFE 20.30' NAVD88 60'-0" EL 16.66' 330' - 3 1/4" EL 13.85' PROPERTY LINE o REAR YARD SETBACK I II I i I ----------------- ---------- I I � I li I , I I I I I I � � � I , II I I toI I z I I F , J I wa � Ali I w Cq w1 a o1 I I m � 7' - 6„ I I I I II I I I 00 I I 7 6„ w I I I o � I � I � � - I I I I I I I EXISTING FENCE , i I I I I I I I I I I I I o I _ 4 A. 134' - 3 1 /2" I I FL. 15 43' i, I � �I ,m 0 iD � I,v I (n W M D m1 I� I I I I I EL 16. I I N I I 55'- 3 3/8" I EL 16.80 I I I I(n la A I,m NEW 4" CONC ETE 0 D WALK AY rn A m Io A o I Im o Z I I i m D m d n m T-6 r.6 m tD 14 I I II o , I I I I I m I z wl �I I � aI I0 UJ Yli I� EL 11.93' SHED d I - NEW 4" CONCRETE PAD I ROOF 4' - 0" / OVERHANG SEPTIC TANK T - 6" o 80, - EL 16.80 ' I I '— EL. 18.111 I I a [AjREA II II EL 16.80' EL15.31• 0 7' - 2" WELL ri lssa' N II I E1165a' r- I I El � I NEW 6" DRIVEWAY, I I CURB CUT PER LOCAL REQUIREMENTS — 16.34 -- __ ______ FRONT YARD SETBACK r, 2? PROPERTY LINE FFE INFORMATION: FLOOD ZONE: FEMA BASE FLOOD ELEVATION: HIGHEST ADJACENT GRADE: CROWN OF THE ROAD: PROPOSED FFE.: SITE PLAN LEGEND EXISTING GRADE �$EL xxxx PROPOSED GRADE '�)MEx MATCH EXISTING GRADE FFE FINISH FLOOR ELEVATION LOW POINT OF SWALE e� ► SLOPE ARROW 34d1 =17.[II&IYI=19wi10I1[oY11 *3 X N/A 16.80' NAVD88 18.36' NAVD88 20.30' NAVD88 1. ALL PAVEMENT IN PUBLIC RIGHT OF WAY SHALL MEET THE DETAILS AND REQUIREMENTS OF THE LOCAL AUTHORITY HAVING JURISDICTION. 2. ALL CURB CUTS AND DRIVEWAY APRONS SHALL MEET THE DETAILS AND REQUIREMENTS OF THE LOCAL AUTHORITY HAVING JURISDICTION. 3. ALL SIDEWALKS WITHIN THE PROPERTY BOUNDARY TO BE 4" THICK, 4000 PSI W/ 6x6-W2.9xW2.9 WWF, AND SHALL RECEIVE BROOM FINISH 90 DEG. TO THE DIRECTION OF TRAVEL. 4. ALL DRIVEWAYS WITHIN THE PROPERTY BOUNDARY TO BE 6" THICK, 4000 PSI W/ 6x6-W2.9xW2.9 WWF, AND SHALL RECEIVE BROOM FINISH 90 DEG. TO THE DIRECTION OF TRAVEL. 5. SLOPE ALL CONCRETE PAVING AWAY FROM BUILDING AT 1% MINIMUM. SLOPE ALL CONCRETE WALKS AWAY FROM BUILDING AT 2% MAXIMUM. 6. SLOPE ALL FINAL GRADING AWAY FROM BUILDING TO ENSURE POSITITVE DRAINAGE. MAXIMUM SLOPE FOR LANDSCAPED AREAS IS 25%. 7. LAY NEW SOD TO COVER ALL AREAS OF YARD DISTURBED BY CONSTRUCTION ACTIVITIES. 8. SITE GRADING PLAN BASED ON AVAILABLE SURVEY DATA. EXISTING DRAINAGE PATTERNS TO BE CONFIRMED IN FIELD BY THE CONTRACTOR. 9. CONTRACTOR SHALL REGRADE SITE IMMEDIATELY ADJACENT TO THE NEWLY CONSTRUCTED HOUSE TO PROVIDE POSITIVE DRAINAGE AWAY FROM THE FOUNDATION OF THE HOME. 10. THE CONTRACTOR SHALL NOT ALTER SITE DRAINAGE PATTERNS IN A WAY THAT DIRECTS ADDITIONAL FLOWS ONTO ADJACENT PROPERTIES, PREMOLDED JOINT MATERIAL OR JOINT FILLER LEFT FLUSH WITH SURFACE OF SIDEWALK w w #4 DOWELS 16" LONG @ 12" O.C., WITH SLEEVES CHAIRS, U CENTERED 2" FROM SURFACE 0? <'A EL 16.65' F_I. 17.06 - El 18A7' F I- 18.36' F I- 17.36' r L 16 80' CORTEZ BLVD 264' - 8 1/4" m SITE PLAN 7K U 1 " = 40'-0" EXISTING CONCRETE PAD TO REMAIN EXISTING POWER POLE TO REMAIN EXISTING GRAVEL DRIVEWAY TO REMAIN 6x6-W2.9xW2.9 WWF SUPPORTED ON CHAIRS @ MIN. ONE PER 9 SQUARE FEET OF WIRE 1/2" EXPANSION JOINT 4 d N a as °a, d SELECT FILL OR AS THIS HALF OF DOWEL SHALL BE DETERMINED BY GREASED UNLESS PLASTIC OR FIELD CONDITIONS EPDXY COATED DOWEL IS USED n SIDEWALK EXPANSION JOINT (EJ) U NOT TO SCALE PREMOLDED JOINT MATERIAL OR JOINT FILLER LEFT FLUSH WITH SURFACE OF SIDEWALK 6x6-W2.9xW2.9 WWF SUPPORTED ON CHAIRS @ MIN. ONE PER 9 #4 DOWELS 16" LONG @ 12" —A N SQUARE FEET OF WIRE O.C., WITH SLEEVES CHAIRS, CENTERED 2" FROM 1/2" EXPANSION U N JOINT 7 d ae N o ,L J M THIS HALF OF DOWEL SHALL BE SELECT FILL OR AS GREASED UNLESS PLASTIC OR DETERMINED BY EPDXY COATED DOWEL IS USED FIELD CONDITIONS n DRIVEWAY EXPANSION JOINT (EJ) U NOT TO SCALE n SWALE SECTION 1/4" = 1'-0" 1:1171AiIJ1 U W 10'-0 TYP. n CONCRETE DRIVEWAY U NOT TO SCALE 90' MAX. TTYPr TYP 3 CONCRETE SIDEWALK NOT TO SCALE SAWCUT OR HARDBOARD PREFORMED STRIP 6x6-W2.9xW2.9 WWF SUPPORTED ON CHAIRS @ MIN. ONE PER 9 SQUARE FEET OF WIRE w N N U m, e 'a d L d z �_J SELECT FILL OR AS DETERMINED BY FIELD CONDITIONS A, DRIVEWAY CONTROL JOINT (CJ) NOT TO SCALE 6x6-W2.9xW2.9 WWF SUPPORTED ON CHAIRS @ MIN. ONE PER 9 = SQUARE FEET OF WIRE7/ a 0 n SIDEWALK CONTROL JOINT (CJ) U NOT TO SCALE SAWCUT OR HARDBOARD PREFORMED STRIP N l0 O N � N 0 0 N z w O r- w a d z M F_ W N Z CN UQ ad U) o S W WLL. ly N Z Z Q Z o Qo •c rn Z c) J 0) m W 00 Wm W O N O 2 33 O W C015 N 4 U) W Z ` 3 y m Q O J J U. m � o NW J Mx FO ® n° O LU U 0 O I.L `Q Project Number 2019-15 Date 11 /23/2021 Drawn By SM Checked By IP FOR CONST54CTION ' \\\ i9t99 tg®® ®�\ JOSIEp/yxN ®or +ems. STATE OF O° � p®®® °'® �i A ae C.1