HomeMy WebLinkAboutCertification For Design Load ComplianceRECER'7D AUG 112017
Planning & Development Services Department
Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553
Certification for Design Load Compliance
Project Name: 1200 Model - 7508 Coquina Ave
Project Address: 7508 Coquina Ave. Fort Pierce, FL 34951
Permit #: Occupancy Type: VB . Construction Type: R-3
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida Residential Code Code Fifth Edition with 20 14 Supplements using ASCE 7-10
2. Structure Designed as (check one): x Enclosed Partially Enclosed Open
3. Risk Category: _I X II III IV Exposure Category: B X C D
4. Design Wind Velocity 160 mph ASD x LRFD End Zone Width: 3 ft
5. Mean Roof Height 12'9" ft Roof Pitch: 4 :12 Parapet: ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: -51.07 Zone 2: -88.90 Zone 3: -131.46 Zone 4: -60.53 Zone 5: -74.71 Garage:
1 7. Design Loads: Floor: PSF Roof/Dead: 25 PSF Roof/Live: 20 Balcony: PSF
Dock: PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF
8. Were Shear Walls Considered For Structure? x Yes Not Applicable Explain Why Not:
>1'
9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that,,to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
forces specified:
Anthony Tombo FL. 80083 31615
Print Name Cert # & Co. Cert Auth.
Whole House Engineering, LLC.
ter..:.. r.•:-• _..,,,
Anthony T. Tombo, 10
Signature, Date, and Seal 4451 St. Lucie Blvd. Fort Pierce, FL 34946
Company Name & Address
Revised 07/25/2014