Loading...
HomeMy WebLinkAboutEPL Display CardV', �• RECEIVED AUG 11 7.017 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD 170� ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPerformance Index, the more efficient the home. - 7508 Coquina Avenue, Ft. Pierce, FL, 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.0 1052.00 ftz b. Interior Frame - Wood, Interior R=13.0 160.00 ft 3. Number of units, if multiple family 1 c. N/A R= ftz 4. Number of Bedrooms 3 d. N/A R= ftz 10. Ceiling Types Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=38.0 1201.00 ftz 6. Conditioned floor area (ftz) 1201 b. N/A R= ftz 7. Windows" Description Area c. N/A R= ft z a: U-Factor: Dbl, U=0.54 113.00 ftz 11. Ducts a. Sup: Attic, Ret: Attic, AH: Attic R ft 6 240 SHGC: SHGC=0.25 b. U-Factor. N/A ftz SHGC: 12. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ftz a. Central Unit 28.0 SEER:16.00 SHGC: d. U-Factor: N/A ftz 13. Heating systems kBtu/hr Efficiency SHGC: a. Electric Strip Heat 27.3 COP:1.00 Area Weighted Average Overhang Depth: 2.944 ft. Area Weighted Average SHGC: 0.250 8. Floor Types Insulation Area 14. Hot water systems Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1199.60 ftz a. Electric EF: 0.95 b. N/A R= ftz c. N/A R= ftz b. Conservation features None 15. Credits CF 163rtify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Cod c mpf nt features. Builder Signature: Date: -� Address of New Home: ��jg Ca®� �� Ur City/FL Zip:Trl ,O�SiiE SrAr��'{�c+ Inn,. i. •'; „ 0 *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 6/28/2017 12:44 PM EnergyGauge® USA - FlaRes2014 - Section R405A.1 Compliant Softwar ` " Page 1 of 1 FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 7508 Coquina Avenue Builder Name: Habitat for Humanity Street: 7508 Coquina Avenue Permit Office: City, State, Zip: Ft. Pierce, FL, Permit Number. Owner: Joe Gianna Jurisdiction: Design Location: FL, Fort Pierce County:: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1212.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.0 1052.00 ft2 b. Interior Frame - Wood, Interior R=13.0 160.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (1201.0 sqft.) Insulation Area a. Under Attic (Vented) R=38.0 1201.00 ft2 6. Conditioned floor area above grade (ft2) 1201 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(113.0 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 240 a. U-Factor: Dbl, U=0.54 113.00 ft2 SHGC: SHGC=0.25 b. U-Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 28.0 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 27.3 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 2.944 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (1199.6 sqft.) Insulation Area EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 1199.60 ft2 b. Conservation features b, N/A R= ft2 None c. N/A R= ft2 15. Credits CF Glass/Floor Area: 0.094 Total Proposed Modified Loads: 43.18 PASS Total Baseline Loads: 43.87 I hereby certify that the plans and specifications covered by Review of the plans and Sr `#his calculation are in compliance with the Florida Energy specifications covered by this 01-TgE Code. calculation indicates compliance with the Florida Energy Code. F• mrr.''% .;;';�. n O PREPARED BY: J-/& Before construction is completed DATE: Urle 28, 2017this building will be inspected for compliance with Section 553.908 I hereby certify that this it ' g, as designed, is in compliance Florida Statutes. y� with the Florida Energ o � G'Op �^�� OWNER/AGEN - BUILDING OFFICIAL: DATE: - f • 7 DATE: - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 6/28/2017 12:43 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2014 PROJECT Title: 7508 Coquina Avenue Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1201 Lot # Owner., Joe Gianna Total Stories: 1 Block/SubDivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Habitat for Humanity Rotate Angle: 0 Street: 7508 Coquina Avenue Permit Office: Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: R. Pierce , Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 2 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1201 9608 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfiIID Finished Cooled Heated 1 Master 159 1272 No 2 1 1 Yes Yes Yes 2 mclst 25 196 No 0 1 Yes Yes Yes 3 Bed 2 121 968 No 1 1 1 Yes Yes Yes 4 clst 2 14 115 No 0 1 Yes Yes Yes 5 clst 3 13 100 No 0 1 No Yes Yes 6 Bed 3 118 944 No 1 1 1 Yes Yes Yes 7 Bath 1 63 504 No 0 1 Yes Yes Yes C 8 Laundry Rm 76 608 No 0 1 Yes Yes Yes 9 Bath 2 49 389 No 0 1 No Yes Yes 10 pnty 9 68 No 0 1 No Yes Yes 11 1 2 16 No 0 1 No Yes Yes 12 Kitchen 123 984 No 0 1 Yes Yes Yes 13 Dining Rm 139 1112 No 0 1 Yes Yes Yes 14 Living Rm 228 1824 No 0 1 Yes Yes Yes 15 Hall 62 497 No 0 1 No Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Master 25.3 ft 0 159 ftz _ 1 0 0 2 Slab -On -Grade Edge Insulatio mcist 3.5 ft 0 24.5 ftZ 1 0 0 3 Slab -On -Grade Edge Insulatio Bed 2 22 ft 0 120.9 ft2 1 0 0 6/28/2017 12:43 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2014 FLOORS # Floor Type Space Perimeter Perimeter R Value Area Joist R Value Tile Wood Carpet 4 Slab -On -Grade Edge Insulatio cast 2 2.5 ft 0 14.4 ft2 1 0 0 5 Slab -On -Grade Edge Insulatio clst 3 1 ft 0 12.5 111:2 1 0 0 6 Slab -On -Grade Edge Insulatio Bed 3 11 ft 0 118.3 ft2 1 0 0 7 Slab -On -Grade Edge Insulatio Bath 1 5.3 ft 0 63 ft2 1 0 0 8 Slab -On -Grade Edge Insulatio Laundry Rm 11.3 ft 0 75.9 ft2 1 0 0 9 Slab -On -Grade Edge Insulatio Bath 2 1 ft 0 48.6 ft2 ___ 1 0 0 10SIab-On-Grade Edge Insulatio pnty 1 ft 0 8.5 ft2 e 1 0 0 11SIab-On-Grade Edge Insulatio 1 1 ft 0 2 ft2 - 1 0 0 12SIab-On-Grade Edge Insulatio Kitchen 10.3 ft 0 123 ft2 - 1 0 0 13SIab-On-Grade Edge Insulatio Dining Rm 9.8 ft 0 138.9 ft2 - 1 0 0 14SIab-On-Grade Edge Insulatio Living Rm 30.8 ft 0 228 1112 _ 1 0 0 15SIab-On-Grade Edge Insulatio Hall 1 ft 0 62.1 ft2 1 0 0 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 1265 ft2 200 ft2 Medium 0.9 No 0.9 No 0 18.4 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic r- Vented 300 1200 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Master 38 Blown 159 ft2 0.1 Wood 2 Under Attic (Vented) mclst 38 Blown 25 ft2 0.1 Wood 3 Under Attic (Vented) Bed 2 38 Blown 121 ft2 0.1 Wood 4 Under Attic (Vented) clst 2 38 Blown 14 ft2 0.1 Wood 5 Under Attic (Vented) clst 3 38 Blown 13 ft2 0.1 Wood 6 Under Attic (Vented) Bed 3 38 Blown 118 ft2 0.1 Wood 7 Under Attic (Vented) Bath 1 38 Blown 63 ft2 0.1 Wood 8 Under Attic (Vented) Laundry Rm 38 Blown 76 ft2 0.1 Wood 9 Under Attic (Vented) Bath 2 38 Blown 49 ft2 0.1 Wood 10 Under Attic (Vented) pnty 38 Blown 9 ft2 0.1 Wood 11 Under Attic (Vented) I • 38 Blown 2 ft2 0.1 Wdod 12 Under Attic (Vented) Kitchen 38 Blown 123 ft2 0.1 Wood 13 Under Attic (Vented) Dining Rm 38 Blown 139 ft2 0.1 Wood 14 Under Attic (Vented) Living Rm 38 Blown 228 ft2 0.1 Wood 15 Under Attic (Vented) Hall 38 Blown 62 ft2 0.1 Wood 6/28/201712:43 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 FnRIUI Rdnr,_gn14 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 1 N Exterior Concrete Block - Int Insul Master 4 12 0 8 0 96.0 ft2 0 0 0.65 0 2 W Exterior Concrete Block - Int Insul Master 4 13 3 8 0 106.0 ft2 0 0 0.65 0 3 N Exterior Concrete Block - Int Insul mcist 4 3 6 8 0 28.0 ft2 0 0 0.65 0 4 N Exterior Concrete Block - Int Insul Bed 2 4 10 9 8 0 86.0 1112 0 0 0.65 0 5 E Exterior Concrete Block - Int Insul Bed 2 4 11 3 8 0 90.0 ft2 0 0 0.65 0 6 E Exterior Concrete Block - Int Insul clst 2 4 2 6 8 0 20.0 ft2 0 0 0.65 0 7 E Exterior Concrete Block - Int Insul Bed 3 4 11 0 8 0 88.0 ft2 0 0 0.65 0 8 W Exterior Concrete Block - Int Insul Bath 1 4 5 3 8 0 42.0 ft2 0 0 0.65 0 _ 9 W Exterior Concrete Block - Int InsuLaundry Rm 4 11 3 8 0 90.0 ft2 0 0 0.65 0 10 W Exterior Concrete Block - Int Insul Kitchen 4 10 3 8 0 82.0 ft2 0 0 0.65 0 11 S Master Interior Frame - Wood Kitchen 13 10 6 8 0 84.0 ft2 0 0.25 0.65 0 12 E Exterior Concrete Block - Int InsulDining Rm 4 9 9 8 0 78.0 ft2 0 0 0.65 0 13 E Exterior Concrete Block - Int Insul Living Rm 4 15 0 8 0 120.0 ft2 0 0 0.65 0 _ 14 S Exterior Concrete Block - Int Insul Living Rm 4 15 9 8 0 126.0 ft2 0 0 0.65 0 _ 15 W Master Interior Frame - Wood Living Rm 13 9 6 8 0 76.0 ft2 0 0.25 0.65 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S Wood Living Rm None .39 3 7 21 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N 1 None Low-E Double Yes 0.54 0.25 15.8 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 2 N 4 None Low-E Double Yes 0.54 0.25 15.8 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 3 E 7 None Low-E Double Yes 0.54 0.25 15.8 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 4 W 10 NoneLow-E Double Yes 0.54 0.25 6.3 ft2 2 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 5 E 12 Wood Low-E Double Yes 0.54 0.25 34.2 ft2 0 ft 0 in 0 ft 0 in Drapes/blinds None 6 S 14 None Low-E Double Yes 0.54 0.25 25.0 ft2 9 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 382.8 ft2 384 ft2 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000355 1119.7 61.47 115.6 .2595 7 6/28/2017 12:43 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 F1'1RM Rdnti-9n1A HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat None COPI 27.3 kBtu/hr 1 sy1#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 16 28 kBtu/hr cfm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ftz DUCTS / — Supply — — Return— Air CFM 25 CFM25 HVAC # V # Location R Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 240 ft2 Attic 60 ftz Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: CoolingJan Heatin [[ ]]Feb Jan (X] Feb Mar Mar H [ ] A r [ ] Apr Ma rlJun rlJul May Jun Jul Au AuSep Se n Oct Oct r , Nov [X] Nov Dec DecVentin Jan II ]] Feb Mar [X] Apr [ May Jun Jul L Aug Se [xl Oct [[[XXx))) Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78' 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68, 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 6/28/2017 12:43 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software . Page 5 of 5 r, + wrightsoft, Load Short Form Entire House WebREPS,LLC Job: 7508 Coquina Avenue Date: June 28, 2017 By: Josh Putman Plan: 7508 Coquina Avenue 1892 Commerce Avenue, Vero Beach, FL 32960 Phone: 800-810-3280 Fax 888-971-2999 Email: sales@webrepshvac.com Web: www.webrepswholesale.com License: CAC0547... Project Information For: Joe Gianna, Habitat for Humanity 2904 Okeechobee Road, Ft. Pierce, FL 34947 Phone: 772-460-6336 Design Information Htg Clg Infiltration Outside db (OF) 43 91 Method Simplified Inside db (OF) 70 75 Construction quality Semi -tight Design TD (OF) 27 16 Fireplaces 0 Daily range - L Inside humidity (%) 30 50 Moisture difference (gr/lb) 0 59 HEATING EQUIPMENT Make Goodman Trade Heat Strip Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat COOLING EQUIPMENT Make Goodman Mfg. Trade GOODMAN Cond GSX160301F Coil ASPT36C14A AHRI ref 6756174 100 EFF Efficiency 13.0 EER, 8.0 kW Sensible cooling 27297 Btuh Latent cooling 27 OF Total cooling 933 cfm Actual air flow. 0.063 cfm/Btuh Air flow factor 0.60 in H2O Static pressure Load sensible heat ratio 16 SEER 19600 Btuh 8400 Btuh 28000 Btuh 933 cfm 0.052 cfm/Btuh 0.60 in H2O 0.74 ROOM NAME Area (ft2) Htg load (Btuh) Clg load (Btuh) Htg AVF (cfm) Clg AVF (cfm) Master 159 2542 2285 160 119 mclst 25 329 171 21 9 Bed 2 121 2345 1854 148 97 clst 2 14 0 0 0 0 clst 3 13 0 0 0 0 Bed 3 118 1402 2042 88 107 Bath 1 63 516 305 33 16 Laundry Rm 76 1040 650 65 34 Bath 2 49 55 - 525 3 27 pnty 9 0 0 0 0 1 2 0 0 0 0 Kitchen 123 1341 3016 84 157 Dining Rm 139 1427 3117 90 163 Ll ving Rm Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 3:e I wrightsoft" Right -Suite® Universal 2017 17.0.23 RSU18998 llnj 0, Pagage AC% ...abitat for Humanity PSLV508 Coquina Avenue.rup Calc = MJ8 Front Door faces: S � �iL�1 riall 0c U u U v Entire House 1200 14811 17886 933 933 Other equip loads 0 1707 Equip. @ 1.00 RSM 19593 Latent cooling 6836 Tf1TA1 a naA70 044 OR4 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Av + wrightsoft• Right -Suite® Universal 2017 17.0.23 RSU16998 AOC% ...abitat for Humanity PSL\7508 Coquina Avenue.rup Calc = MJ8 Front Door faces: S 2017-Jun-28 13:00:59 Page 2