Loading...
HomeMy WebLinkAboutFlorida Product ApprovalsWHOLE HOUSE ENGINEERING RECEIb'rD AUG 112017 Whole House Engineering, LLC 4451 St. Lucie Blvd. Fort Pierce, FL 34946 (772) 409-1010 office (772) 409-1015 fax Florida Product Approvals Project Name 1200 Model LYI1i)LL IiCR!SE EZG3N1.£:RL\G ✓❑ APPROVED ❑ REJECTED ❑ REVISE ❑ NOT REVIEWED By atombo DATE 7/17/2017 SUBMITTAL# SPEC This review is only for general conformance of the project and general compliance. Corrections or comments made on these drawings during this review do not relieve Contractor/Subcontractor from compliance with the requirements of the plans and specifications. Contractor is responsible for all dimensions and fabrication to be confirmed and correlated at the job site Project: 1200 Model Customer Name: Habitat for Humanity Site Name: 7508 Coquina Ave. Site Address: 7508 Coquina Ave, , Fort Pierce, FL 349��� Table of Contents Item Page Therma-Tru Smooth Star Door............................................................................................................................. 1 CustomWindow System SGD8920...................................................................................................................... 2 CustomWindow System SH-8100....................................................................................................................... DAB824-811 Garage Door................................................................................................................................... 4 OwensCorning Duration Shingles....................................................................................................................... 12 R W RV Building Consultants, Inc. B Consulting and Engineering Services for the Building industry C P.O. Box 230 Valrico, FL 33595 Phone 813.659,9197 Florida Board of Professional Engineers Certificate of Authorization No. 9813 Product Category Sub Category Manufacturer Product Name Therma Tru Corporation 3'0" x WV' Exterior Swinging Exterior Door 118 Industrial Drive "Smooth Star" Doors Assemblies Edgerton, ON 43517 Fiberglass Single Door Phone 419.298.1740 Inswing l Outswin "Impact", Scope: This is a Product Evaluation report issued by R W Building Consultants, Inc. and Lyndon F. Schmidt, P.E. for Therma Tru Corporation based on Rule Chapter No. 61G20-3, Method 1 D of the State of Florida Product Approval, Department of Business & Professional Regulation. RW Building Consultants and Lyndon F. Schmidt, P.E. do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. Limitations. 1.. This product has been evaluated and. is in compliance with the 5th Edition (2014) Florida Building Code (FBC) structural requirements excluding the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind bome debris protection this product complies with Section 1609.1.2 of the FBC and does not require an impact resistant covering. This product meets missile level "'D" and excludes Wind Zone 4 as defined in ASTM E1996 and Section 1609.1.2.2 of the FBC. 4. For 2x stud framing construction, anchoring of these units shall be the same as that shown for 2x buck masonry construction. 5. Site conditions that deviate from the details of drawing FL-5891.2 require further engineering analysis by a licensed engineer or registered architect. " 6. See drawing FL-5891.2 for size and design pressure limitations. Supporting Documents: 1. Test Report No, ETC 01-741-10700.0 CTLA 98OW 2. Drawing No. No. FL-5891.2 3. Calculations Anchoring Test Standard TAS 202-94 SSTD 12 99 Prepared by RW Building Consultants, Inc. (CA #9813) Prepared.by RW Building Consultants, Inc. (CA #9813) 4. Qualitv.Assurance Certificate of Participation issued by NationalAccreditation and Management Institute, certifying that Therma Tru Corporation is manufacturing products within a quality assurance program that complies with ISONEC 17020 and Guide 53. Sheet 1 of 1 Testing Laboratory Slgned by ETC Laboratories Wendell W. Haney, P.E. Certified Testing Laboratories Ramesh Patel, P.E. Signed & Sealed by Lyndon F. Schmidt, P.E. Signed & Sealed. by ����rltan�$trcP Lyndon F. Schmidt, P.E. S. Na 43zo@ 0 m ..gy�pp,, �1 • ^ rv`Lyndon F. Schmidt, P.E. FL PE No. 43409 1/29/2015 E,gg X17 0 URNER ENGINEERING & CONSULTING, INC. 1239 Jabara Ave. North Port, FL 34288 Ph. 941-380-1574 FBPE C.O.A. #29779 Evaluation Report 252G February 26, 2015 Product Description: Series 8920 Sliding Glass Door, LM Impact, 4'x8' nominal max. panel Manufacturer: Custom Window Systems, Inc. 1900 SW 446' Ave, Ocala, FL 34474 Statement of Compliance: This report evaluates the above -listed product per the requirements of FAC Product Approval Rule Chapter 61 G20-3.005 (4). This product complies with the requirements of the Florida Building Code including the High Velocity Hurricane Zone. The product testing standards performed are outlined below. Technical Documentation: 1) This report, prepared by Lucas A. Turner, P.E., at 1239 Jabara Ave., North Port, FL 2) Approval drawing CWS-252G, signed and sealed by Lucas A. Turner, P.E. 3) Test Reports NCTL-210-3429-1 and -lA, and NCTL-210-3888-1, -lA, -2, and -2A, from National Certified Testing Laboratories, Orlando, FL signed and sealed by Gerard J. Ferrara, P.E., with testing performed: TAS 201/202/203 1994, AAMA/WDMA/CSA 101/I.S.2/A440-2005/2008, and ASTM E 1886/1996 2002/2006 4) Supplemental Calculations to support CWS-252G, signed and sealed by Lucas A. Turner, P.E. Installation: Units must be installed according to approval document CWS-252G. Limitations of Use: This product: • May be used in up to 49 1/8" x 93 3/16" panel sizes (96" max. door height), with glass type and max. glass daylight sizes as shown in CWS-252G • Achieves design pressures of +/-67.5 psf with sill riser 1698 • Is Large Missile Impact Resistant and does not require the use of shutters • May be used in the High Velocity Hurricane Zone • For up to 96" door heights with 4' nominal panel widths, requires Dupont SentryGlas (formerly SentryGlas Plus or SGP) Interlayer per Miami -Dade N.O.A. #11-0624.02. For up to 80" door heights with 3' nominal panel widths, requires Dupont Butacite PVB Interlayer per Miami -Dade N.O.A. #13-0129.27. • Requires Mikron rigid PVC frame extrusions per Miami -Dade N.O.A.# 12-1017.02 Certification of Independence: I do not have, nor do I intend to acquire, nor will I acquire, a financial interest in Custom Window Systems or in any company manufacturing or distributing products for which this report is being issued. I do not have, nor do I intend to acquire, nor will I acquire, a financial interest in any other entity involved in the testing or approval process of this product. No 9582,0 i 2/26/2015 s F99 q py. n Lucas A. TurNP qCero �.�yv STATE OF +p�4U �¢ ,* -- 0 R ,� er, P.E. FL PE #58201 r� URNER ENGINEERING & CONSULTING, INC. 1239 Jabara Ave. North Port, FL 34288 Ph. 941-380-1574 FBPE C.O.A. 429779 Evaluation Report 812B April 18, 2015 Product Description: Series 8100 PVC Single Hung, Large Missile Impact, 51 7/8" x 61 3/4" unit size, +/-70 PSF, no anchors in sill Manufacturer: Custom Window Systems, Inc. 1900 SW 441h Ave, Ocala, FL 34474 Statement of Compliance: This report evaluates the above -listed product per the requirements of FAC Product Approval Rule Chapter 61 G20-3.005 (4). This product complies with the requirements of the 5"h Edition (2014) Florida Building Code including the High Velocity Hurricane Zone. The product testing standards performed are outlined below. Technical Documentation: 1) This report, prepared by Lucas A. Turner, P.E., at 1239 Jabara Ave., North Port, FL 2) Approval drawing CWS-81213, signed and sealed by Lucas A. Turner, P.E. 3) Test Report NCTL-210-3815-IA, -2, and -2A, by National Certified Testing Laboratories, Orlando, FL, signed and sealed by Gerard J. Ferrara, with testing performed: TAS 201/202/203- 94, ASTM E 1886-02/04/05, 1996-02/04/06/09, and AAMA/WDMA/CSA 101/I.S.2/A440-08 4) Supplemental Calculations to support CWS-81213, signed and sealed by Lucas A. Turner, P.E. Installation: Units must be installed according to approval document CWS-812B. Limitations of Use: This product: • May be used in O/X configuration in sizes and with max. glass DLO heights as shown in CWS- 812B • Is impact resistant and does not require the use of shutters • May be used in the High Velocity Hurricane Zone • Requires 7/8" Insulating Glass consisting of 1/8 Annealed or Tempered outboard lite (Tempered required above 30 ft in HVHZ) — Air— 5/16 Laminated (1/8Ann-.090PVB-1/8Ann) inboard lite • Requires Dupont PVB Interlayer per Miami -Dade N.O.A. 13-0129.27' • Requires Quanex (Mikron) white rigid PVC framing per Miami -Dade N.O.A. 12-1017.02t t I have evaluated the interlayer and framing materials in these Dupont and Quanex NOAs and find that they comply with the requirements of the 5`h Ed. (2014) Florida Building Code for use in this product. Certification of Independence: I do not have, nor do I intend to acquire, nor will I acquire, a financial interest in Custom Window Systems or in any company manufacturing or distributing products for which this report is being issued. I do not have, nor do I intend to acquire, nor will I acquire, a financial interest in any other entity involved in the testing or approval process of this product. ��4iAi7�Yl=f� $ Mt���,y,,IDRE % i v v o 513201 afrt `•, w w .0. OF 40 4/18/2015 Lucas A. Turner, P.E. FL PE PP 0 3of17COP111" MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy DAB Door Company, Inc. 12195 NW 98' Avenue Hialeah Gardens, FL 33018 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Hurricane Master Model 8241811 Steel Sectional Garage Door up to 9'4" Wide w/ Window Lite Option (DP +50.0, -60.0 PSF) APPROVAL DOCUMENT: Drawing No. 01-09, titled "Sectional Garage Door", sheets 1 through 5 of 5, dated 02/01/2001, with last revision K dated 03/21/2016, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E., bearing the Miami -Dade County Product Control renewal stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: A permanent label with the manufacturer's name or logo, manufacturing address, model number, the positive and negative design pressure rating, indicate impact rated if applicable, installation instruction drawing reference number, approval number (NOA), the applicable test standards, and the statement reading `Miami -Dade County Product Control Approved' is to be located on the door's side track, bottom angle, or inner surface of a panel. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA # 15-0317.02 and consists of this page 1 and evidence pages E-1 and E-2, as well as approval document mentioned above. The submitted documentation was reviewed by Carlos M. Utrera, P.E. NOA No. 16-0330.02 Expiration Dat ust 21 p , f1z�G Approval J{ue 3, h01 LP y Page 4 of 17 DAB Door Company, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBNUTTED A. DRAWINGS 1. Drawing No. 01-09, titled "Sectional Garage Door", sheets 1 through 5 of 5, dated 02/01/2001, with last revision K dated 03/21/2016, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. B. TESTS "Submitted under NOA # 09-0128.04" 1. Test reports on 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 4) Forced Entry Test, per FBC 2411 3.2.1, TAS 202-94 along with marked -up drawings and installation diagram of a DAB 824 24 GA Sectional Garage Door with Fixed Windows, prepared by Hurricane Engineering & Testing, Inc, Test Reports No. HETI-08-2149A/B, dated 06/27/2008, signed and sealed by Candido F. Font, P.E. "Submitted under NOA # 09-0128.04" 2. Test report of Tensile Test per ASTM E 8, Report No. HETI 08-T182, prepared by Hurricane Engineering & Testing, Inc., dated 12/23/2008, signed and sealed by Candido F. Font, P.E. "Submitted under NOA # 01-0516.03" 3. Test report of large missile impact test per PA 201 and cyclic wind pressure test per PA 203 on "Sectional Residential Garage Door", prepared by Hurricane Engineering & Testing, Inc., Report No. HETI 01-974A, dated 01/29/2001, signed and sealed by Hector M. Medina, P.E. 4. Test report of Uniform Static Air Pressure Test per PA 202 and Force Entry Resistance Test on "Sectional Residential Garage Door", prepared by Hurricane Engineering & Testing, Inc., Report No. HETI 01-969, dated 01/18/2001, signed and sealed by Hector M. Medina, P.E. 5. Test report on Salt Spray (Corrosion) Test per ASTM B 117 of a painted G-40 steel panels, prepared by Celotex Corporation, Test Report No. 258592, dated 08/17/1998, signed by W. A. Jackson, P.E. Od�i��241� Carlos M. Utrera, P.R. Product Control Examiner NOA No. 16-0330.02 Expiration Date: August 9, 2021 Approval Date: June 23, 2016 E-1 Page 5 of 17 DAB Door Company, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED C. CALCULATIONS "Submitted under NOA # 14-0814.04" 1. Anchor verification calculations prepared by Al-Farooq Corporation, dated 09/22/2014 and 07/24/2014, signed and sealed by Javad Ahmad, P.E. "Submitted under NOA # 09-0128.04" 2. Anchor verification calculations prepared by AI-Farooq Corporation, complying with F.B.0 2007, dated 12/19/2008, signed and sealed by Humayoun Farooq, P.E. D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER) E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 15-0915.08, issued to SABIC Innovative Plastics, for their Lexan PoIycarbonate Sheet Products, approved on 12/10/2015 and expiring on 07/17/2018. 2. Notice of Acceptance No. 14-0311.08, issued to Insulfoam, LLC, for their Insulfoam Expanded Polystyrene Insulation, approved on 08/14/2014 and expiring on 11/29/2017. 3. Notice of Acceptance No. 11-0926.07, issued to Dyplast Products, LLC, for their Expanded Polystyrene Block Type Insulation, approved on 11/10/2011 and expiring on 01/11/2017. 4. Notice of Acceptance No. 11-0926.06, issued to Dyplast Products, LLC, for their Dyplast ISO -CI Polyisocyanurate Insulation, approved on 11/10/2011 and expiring on 01/11/2017. 5. Notice of Acceptance No. 15-1203.04, issued to Cellofoam North America Inc, for their Expanded Polystyrene Block Insulation, approved on 03/17/2016 and expiring on 02/24/2021. "Submitted under NOA # 05-0228. 02" 6. Test Report on Accelerated Weathering Using Xenon Arc Light Apparatus Test per ASTM G155 of "PVC Extrusion Material", prepared by Hurricane Engineering & Testing, Inc., Report No. HETI 04-A002, dated 09/27/2004, signed and sealed by Rafael E. Droz-Seda, P.E. 7. Test Reports on Tensile Test per ASTM D638 of "PVC Extrusion Material", prepared by Hurricane Engineering & Testing Inc., Report No. HETI 04-T251, dated 11/29/2004 signed and sealed by I. Ghia, P.E. 8. Test Report on Self -Ignition Temperature Test, Rate of Burn Test and Smoke Density Test of "REHAU non -foam PVC extrusion material', prepared by ETC Laboratories, Report No. 04-761-15019.0, dated 05/06/2004, signed and sealed by J. L. Doldan, P.E. F. STATEMENTS 1. Statement letter of code conformance to the 5" edition (2014) FBC and of no financial interest issued by Al-Farooq Corporation, dated 03/21/2016, signed and sealed by Javad hmad, P.E. Carlos M. Utrern, P.E. Product Control Examiner NOA No. 16-0330.02 Expiration Date: August 9, 2021 Approval F Jun 23--016 n t Page 6 of DOOR HEIGKrj CONSISTS Of 6'-6' 2 SECTIONS 18- 2 SECTIONS 21' W-9' 1 SEC.ON 19" 3 SECTIONS 21' 7' T-3' 4 SECTIONS 21' - 5 SECTONS Is' 7 T-9" 4 SECTIONS 1W 1 SECTION 21" 6' 3 SECTIONS 18' 2 SECTIONS 21' W3' 2 SECTIONS 18" 3 SECTIONS 21' V-6' 1 SECTION le 4 SECTIONS 21' 8'-9'--- 5 SECTIONS 21" - 9' a SECTIONS TV - W:Iq 5 SECTIONS 18' 1 SFCnON 21' 9'-6' 4 SECTIONS 15' 2 SECTIONS 21' 9'-9' 3 SECTIONS is' 3 SECTIONS 21' To' 2 SECTIONS 18" 4 SECTIONS 21' 10'-3' 1 SECTION 18 5 SECTIONS 21' lo'-e' 6 SECTIONS 21' - 10'-9' a SECTIONS 13" 1 SECTION 21" 11' 5 SECTIONS le' 2 SECTIONS 21' 11'-3' 4 SECTIONS 18' 3 SECTIONS 21' 11'SECTIONS 15" 4 SECTIONS 21" 2 SECTIONS 18' 5 SECTIONS 21' 1Y 1 SECTIONS 18" 6 SECTIONS 21- 12-3' 17 SEIMCNS 21- - 12'-6' 6 SECIICNS TO- 2 SECTIONS 21N 12'-9' IS SECTIONS 18' 3 sWnDNS 21' 13' 14 SECTIONS is' 4 SECTIDNS 21' 13'-3' .3 SECTIONS 18" S SECTIONS 21' 13'-6' 2 SECTIONS 11' 6 SECTIONS 21' 13'-9' 1 SECTION 78- 7 SECTIONS 21- 14' 8 SECTIONS 21" - Ie-3" 6 SECTIONS TV 3 SECTIONS 21" 14'-V 5 SECTIONS IS' 4 SECTIONS 21- 14'-9' 4 SECTIONS 18' 5 SECTIONS 21" 15' !3 SECTIONS 18" 6 SECTIONS 21' 15'-3' 2 SECTIONS 18' 7 SECTIONS 21" 15-:!. 1 SECTION 18' 8 SECTIONS 21- 15-9- 19 SECTIONS 21- - 16' 16 SECTIONS 18' 4 SECTIONS 21" 7-1/2" X 3" X .071' GALV. STEEL END ROLLER HINGE W/ (6) #14 X 5/8' SMS /p WITHOUT DELRON SLEEVE (STC.) WITH DELRON SLEEVE (OPTIONAL) ` ` oB 0o I \ \a � B 1 1 , 1 I 1 7-1/2" X 2-1/4" X .071' i -- 1A\ o W `4STEEL XEMER IRE . \� WYTH DELRON SLEEVE (OPTIONAL) 8 LOCK - - 2/ DOOR o\ 1' W % .15' TNK. LATCH I � STANDARD LOCK \� SPRING LOADED SLIDE BOLT (BOTH SIDES)TENW FASED / (4) #14 X 1/2" S.M.S. -- 5/8' MIN. LOCK ENGAGEMENT CONFORMS TO SECTION 1008 REGARDING GARAGE` DOORS 6"X3"X 0.1" STEEL PLATE WITH (2) #14 X 5/8" SMS CENTER STILE BRACKET / BRACKET STD. LIFT DOOR LOW HEADROOM DOOR OPTION TOP FIXTURE 5-1/2' X 2-3/4" X 0.1" STEEL PLATE WITH ONE 5/16-1B MS W/ NUT `FASTENED TO END STILE WITH OPTIONAL DOOR VIEWER (6) #14 X 3/4" SELF DRIVING SCREWS TO BE INSTALLED AT CENTER SOLE CENTER STILE-1/ I I I _ � m B �Eo = m o0 0 e b o w o - O - - W T. ® a N I I Irl i OPTIONAL VENr L -.- A (3) 5" MCE AT 7" D,C. MAX. NG AREA NOT TO EXCEED COLONIAL DESIGN Q. IN. L-fo-s". MAX. DOOR WIDTH \-OPTIONAL FLUSH PAC W030 GRAIN DESIGN 9-4 INSIDE ELEVATION RAISED PANEL EMBOSSED DOOR 7-7/8' X 3-1 / 8' X .010' STEEL PLATE WITH (4) #14 X 3/4" SD.; #14 X 3/4" SELF DRILLING SCREWS MAY BE USED IN LIEU OF #14 X 5/8" SMS THIS PRODUCT IS RATED FOR LARGE MISSILE IMPACT I�LOCK BAR GUIDES INSTALLED ON END STILE WITN (4) J14 X 5/8" SMS 8T X .5W LOCK BAR ENGAGES IN TRACK ON EACH SIDE OF DOOR OUTSIDE KEYED LOCK (OPTIONAL) LOCK BAR LOCKING SHOWN ALTERNATE TO SPRING LOADED SURE BOLT LOCKS SHOWN ABOVE STILE GENERAL NOTES L. THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE REOUIROADM OF THE 2014 (STH EDITION) FLORIDA BUILDING CODE INCLUDING HIGH VELOCITY HURRICANE ZONE (HVHZ). 2. ANCHORS SHALL BE AS LISTED, SPACED AS SHOWN ON DETAILS. ANCHOR EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. 3. ALL BOLTS, NUTS AND WASHERS SHALL BE ZINC PLATED CARBON STEEL 4. ANCHORING OR LOADING CONDITIONS OTHER THAN THOSE SHOWN IN THESE DETAILS ARE NOT" PART OF THIS APPROVAL 5. A LOAD DURATION INCREASE IS USED IN DESIGN OF ANCHORS INTO WOOD ONLY. DOOR TESTED TIT ACCORDANCE WITH THE REOUIREMENTS OF FLORDA BUILDING CODE, TAS-202. TAS-201 k TAS-203 FOR HVHZ AND ASTM E1896-OS/AMU E1996-09. 4w U Z yn CZ R �a 2� go o a u In WO otm O o' a MQ Daoo o -3 g VJp (L t 0, samE QuT7NSK LX W2 O o O 17 C3 W Q Z b 0 0 3j N U O z � M Ti a) d� o DAB DOORS INC. co_ € Hurricane Master'N Model 824/81 1 v w Max. Size 9'-4' X 16'-0" High u With Window Lite Option u 2 i DESIGN PRESSURE RATING = + 50.0 PSF e o m a - 60.0 PSF PRODUCT RENEWED `1 S ^ B B - as complying with the Florida Building Code NOA-No. 16-0330.02 Expiration 08/09/2021 By ETlSF Mi2m]-Dhdf Product Control0592 OF 01-09 FOR CONNECTION OF WOOD BUCK / TO MASONRY SEE NOTE ON SHEET 4 SOUTHERN PINE 0.55 S.G. ` EDG GIST' 1 1 1/2° MIN. 1.9' X 2.19' X 3.3' X .102' STEEL TRACK BRACKETS SEE SHEET 3 FOR SPACING 24 GA. STEEL PANEL -I 3/16" ALUM RIVETS Z g�� 4� m q CW9 PANEL I 6 Z FLAPS BEM OVER 6 A Y1 a O W N 19 1/2' PUNCHED HOLES I ii I.iri .C24' STL PANEL 0 4' O.C. 1 � CC C OUTSID= OF 000 T IL 0 I yq�Ny�n O I Q W ul LL o - __� Iikj1 Zz ys�� I c STEEL TRACK BRACKET FASTzNEO SOLID BRASS DOOR VIEWER TO WOOD JAMB WITH BY 'SCHLAGE SECURITY HARDWARE' 5/16- X 1-5/8- LAG SCREW INSTALLED IN 9/16' CIA. HOLES IN CENTER STILE (FULLY THREADED) POSITIONED AT EYE LEVEL ONE PER BRACKET END STILE O DO p AT TRACK BRACKET, o M OPTIONAL STOP MOULDING A) 3/8' DW POWER -BOLT BY 'POWER5 A) l,l BY ODOR INSTALLER 2' MN. EMBED INTO CONCRETE . < 1-7/8' MIN. EDGE DISTANCE 0= U 2 a 114 X 5/8' SMS 3/4' X 2- X 2-1/2' X 18 GA. STEEL B) 3/8' DL_ HL - Sf FFVF BY 'Han' Z V z $ 6 PER HINGE END STILE. CONNECT 6 PANELS VETH 1/2° X 1-3/4' X FORMED STEEL FLAPS AND 3/16' ALUM RIVE75 1-1/4' MIN. EMBED INTO CONCRETE OR FILLED BLOCK , —QI ID 0 W � w p 1 .059' -GLUED TO PANEL AND SECURED TO SEE DETAIL ABOVE 1-5/8- MIN. EDGE DISANCE INTO CONCRETE END STILE WITH 3/15' PCP HIVL15 ® 12- U.C. 4' M;N. EDGE DISTANCE INTO FILLED BLOCK O Z U U 1-7/8' X 2-5/8' X .045' STEEL STILE. GLUED AND RIVETED EDGECONCRETE fc = 3000 PSI MIN. 0-90 GROUT FILLED BLOCK fm 2000 PSI MIN. N r� 1 TO PANEL W/ (4) 3/18' RIVETS DISTANCE I I N g �CENTER FOP RN�\4 B' S.M.B. 4/HGE I I I I I / 7/16' PUSHNUT INSTALLED ON ROLLER SHAFT STEEL TRACK 14 GA. X 2-1/8' X 1' (STANDARD) 12 GA. X 3-5/16' X 1-1/2' (OPTIONAL) FASTENED TO TRACK PLATES W/ 1/4-20 X 5/e' TRUSS 140. SLOTTED M.S. & LOCK NUT 7-1/2' X .071' OALV. STEEL) CENTER HNGE SECTION 8- INTERIOR SIDE 7-1/2- X 3' X .071 J END ROLLER HINGE 1.82' DMA X .50' STEEL ROLLERS 1.82' DIA. X 50' NYLON ROLLERS (OPTI 2.75' DIA. X .50' STEEL ROLLERS (OPT1 2.75' DIA. X .50' NYLON ROLLERS (OPT] wrN 6' ANCHOR TYPE A OR B (1) PER BRACKET SEE SHEET 3 FOR BRACKET SPACING SS BOLT & NUT PRODUCT RENEWED as wmPlying -- the Florida Building Code NOA-No. 16-0330.02 EuplMu7 qe�e 00/09/2021 By .1LL Mlaml-0"aIn Pmduct Control � rljr� ENyF� � I o n Egg •; �+� malt��•,,"��®.�4 O drawing no. 01 —09 dAL `` III11/ sheet i9B� 1 11101111110. ow. SECTION A -A RIVETS ' 2-3/4" X 5-1/2' X 3' X .104' GAI.Y. STEEL TOP ROLLER BRACKET ON EACH SIDE FASTENED W/ (6) 111 14 X 5/8' S.M.S. .090 THY GALV. STEEL ADJUSTABLE SLIDE FASTENED TO RRACKEf . W/ 5116-18 X 3/4" HEX HEAD M. 51;RM 11 NUTS, TO P BRACKET (STANDARD) TOP BRACKET 5/16° X 1-5/8' LAC SCREWS INTO WOOD OR 5/16" SLEEVE ANCHORS WITH 1-1/4" EMBED INTO MASONRY) 3 PER BRACKET X 4-1/4' X 13 GA. STEEL PIATFS WELCED TO 1-1/2- X 1-1/2' X 14 GA. ANG'•E FASTENED TO TRACK WITH (4) 1/4-20 SS. BOLT & NUTS HORIZONTAL REINFORCEMENT 1/2' X 1-3/4" % .059' FORMED STER. Y X 5-1/2' % .104" GLUED TO PANEL AI1D FASTENTD TO GAILY. STEEL VERTICAL STILES WITH FASTENED W/ ((4) % 14 % 5/8" S.MS. (2) 3/10' POP RIVETS 40P ROLLER 1PJ`LKET FOR LOW IIEADROOM DOOR OPTION HORIZONTAL REINFORCEMENT 1/2' X 1-3/4' X .as9' FORMED STEEL 0LUE0 TO PANEL AND FASTENED TO VERTICAL STLES WITH (2) 3/16" POP RVETS -5/16" MEETING RIB 1.82" OW. X .50" ROLLERS �W/ .44 DLA. X 4-1/4' STEM OPTIONAL INSULATIONS: 'DYPLAST BY PRODUCTS LLC' FPS-EXPANOEO POLYSTYRENE OENSTTY = 1.05 PCF N.OA #11-0926.07 OR ISO-25 POLY-ISOC1'ANURATE DENSITY m 2.0 PCF —N.OA Ij11-0926.05 OR BY 'CE IO9 NORTH AMERICA' OENSfTY .03 PCF N.OA #15-1203.04 OR 'Mc I FOAM I ' 8Y DENSITY = 0.92 PCF N.OA #14-0311.05 ,114 GA GALV. STEEL ROLLER HINGES FASTENED W/ (4) 914 X 5/8' SMS MIN. -024' ROLL FORMED STEEL PANEL ORAWING QUALITY C-40 MIN. YIELD STRENGTH - 34 KS1 — WITH PH'AK MER AND BED -ON PO:YSTER PAINTED TOP COAT APPLIED TO BOTH SIDES OF STEEL 12 GA. GALY. STEEL BOTTOM W/ (4) #14CXE5/Bl' SMSFASTENED DM SEAL OPTIONS SHEET 4 m m HORIZ TRACK SUPPOF CENTER SUPPORT REQO. ON D001 EXFEEDING 8 Fr. IN HEIGI II A._ J TRACK LENGTH _ OPENING FIDGIT P.US 12" 0A GALV. STEEL TRACK 2 % 2 X 1/8" HORIZ TRACE CKET SPOT TO HORIZ TRACK {{� WITH lYlO YIELDS AT 1-1/2' APART VIEWS FIRST AT 3' O.C. �Y REST AT 9' D.C.— CONNECTED TO FLAG BRACKE- ANGLE Z W/ 3/8-16 X 3/4" BOLT & NUT GUIDE WITH q 41 W AND TO SPRING SHAFT 1/4-20 X 5/8' BOLT & NUT/ (2) O 0 m fl O t a ti VERTICAL TRACK O 2-1/8" X 1" X .090' SECTION A -A M C & ¢ m 0 Ug ONy� O N PLACEMENTS Q W7 L N 0, Z -L Z ¢ B4 B5 B6 87 B8 _ T9 w Qw0E W, DOOR • SECTION HEIGHTS BRA HEIGHT IST 2N0 3RD 4TH STH B7 D2 B3 6'-0' 18 18 18 18 N/A 1" TO 2' 11-3/4' 23' 34 45 So 67 6'-6' 21`18° 18" 21"iN/A 1' TO 2' 11-3/4" 23" 34' 45 Sb` 67' - 7'-0-- 1' TO 2" 11-3/4" 23' 34" 45" 56" 67' - 7'-6' 1" TO 2" 11-3/4" 23" 34" 45` 56" 67' 78-1/4" 8'-0" 21`! 18` 18 16 I21" 1' TO 2" 11-3/4" 23" 34" 45' 56" 67' 78-1/4" --�tuluv� Arte rvumeenr Itic u.o n Inc ovu�in FOR DOORS MORE THAN 8 FT. HIGH. USE ADOTTIONA_ TRACK BRACKETS AT 10' O.C. 1-9' X2.19'X 3.3"X.090" STEEL TRACK BRACKETS 2-3/16- HIGH CONNECTED TO TRACK WITH kl) i/4- BOLTS & NUTS. VERTICAL LIFT HIGHLI STANDARD LIFT• LOW HEADROOM DOUBLE TRACK AVAMBLE TRACK OPTIONS PRODUCT RENEWED sF' as Qom %,I7 with the Florida Budding Code NOA-No. 16-0330.02 3 Expiration te08/09/2021 6y � O••. ATE OF '�� A20RIDT;.+ aliom u e Product Control iY S� -•••- • ' Z b!, �AdIII III K � 0 0 O M O M W Q Q A Z P: vi A 00 W y oa o I 0 OSy N O i I drawing no. 01-09 a z 1-1/2" MIN. s I E DIST. 3 4' IN. GE DIST. p / f �+ \ m is X I- SELF DRILLING SCREWS OR 3/16' 'FNE1(' STEEL RNETS� MULRCRIP W/ DOME HEAD NT 1/2" X 1-3/4' X .058' FORMED STEEL FORMED STEEL SEX 1' SELF GRILLING SCREWS OR 3/16' 'RNDC STEEL F}1 �Y ,� m O H a k rP gm / S AT 48' O.C. HEAD / MULTIGRIP W/ DOME HEAD AT "� F > LuY RETNFORC ENT 0 080 ',r \ 1/2' X 1-3/4" X .058' FORMFO STEEL DO i v a Q 2EY 1/4' DW LAG SCREWS "�, i/4- OIA. LAG SCREWS 1YOOD BU I \ I \ A7 6' FROM ENDS WC00 DUj'JE I AND 19" O.C. MAX. / AT 6' FROM ENDS AND 19' O.C. MAX. 0 I \ I W-STRIPAIADAPTER IV'STRIP ACAPTER ur11 G' OO C o a STFFI. 0 a O ��ZoRUBBER W'STRIPPING RUBBER WSTRIPPINC JJ Q W 7 p .534 I{. Z rpwp '� Z 34-1 Q w m c L k---1.750•� 1.79C--i� BOTTOM SEAL OPTIONS I f II OPTION 'A' �� OPTION 'B�/ WOOD BUCK CONNECTION TO WOOD SUBSTRATE (WOOD SPECIFIC GRAVITY SG=0.55 MIN.) TH= INSTALLATION METHODS SHOWN ABOVE SHOWS 2X6 SYP WOOD BUCK ATTACHMENT TO WOOD STRUCTURES. IF THESE METHODS ARE FOLLOWED NO ADDITIONAL CALCULATIONS/DESIGN WILL BE REQUIRED FOR DESIGN OF GARAGE DOOR ANCHORAGE FOR DOOR REPLACEMENT APPLICATIONS WITH NO ENGINEER OF RECORD, INSTALLATION MAY EE VERIFIED AND APPROVED BY THE BUILDING OFFICIAL UPON INSPECTION. 5/16- X 1-5/8- LAG SCREWS AT 12' D.C. / WOOD BUCK CONNECTION TO MASONRY PRESSURE TRFATFJ) 2X5 SIP WOOD JAMBS WHICH SHALL BE ANCHORED TO " GROUTED REINFORCED MASONRY BLOCK WALL OR CONC. COLUMN WTH 1 TO' ULTRACON BY =1C0' WITH SPACING OF O.C. INTO CROUT FILLED BLOCK WALL, WITH 2-1/4' MIN. EMBED 15. O.C. INTO 3000 PSI CONCRETE• WrH 1-3/4, MIN. EMBED 2-1/2' MIN. EDGE DISTANCE I 1-1/2' 1/4' TAPPER BY 'POW'ERS' W-TH SPACING OF 14' OC. INTO GROUT FILLED BLOCK WALL, WITH 1-1/2' MIN. EMBED Is" O.C. INTO 3000 PSI CONCRETE, WITH 1-3/4' MIN. EMBED 1/1 X 2-1 1 -WE 3' MIN. EDGE DISTANCE FILLET FI 3/B' CONFLEX BY 'ELCO- OR OR AT 12' O.C. I 3/8" LDT BY 'ITW WITH OF 24' D.C. IN70 3D00 PSI CONCRETE WITH 2-1/2- MIN. EMBED 2 MIN. EDGE DISTANCE CONTINUOUS ANM F_ TRACK 3/8' HLC SLEEVE BY 'NILTI' WITH SPACING OF 70 W000 BUCK 8" O.G. INTO GROUT FILLED BLOCK WALL, WITH i-1/4' MIN. EMBED, 4' MIN. EDGE DLST. 18' C.C.INTO =0 PSI CONCRETE, WITH 1-1/4' MIN. EMBED AND 2-1/2- MIN. EDGE DISTANCE PREPARAMON OF BY BY�ERS FOR NEW CONSTRUCTION ENGINEER OF RECORD OR ARCHITECT TO VERIFY ADEOLACY OF SUPPORTING STRUCTURE TO SUPPORT LOADS IMPOSED BY DOOR SYSTEM. FOR DOOR REPLACEMENT IN RETROFIT BUILDINGS WITH NO ENGINEER OF RECORD, DOOR INSTALLATION MAY BE REVIEWED AND APPROVED BY BUILDING OFFICIAL UPON INSPECTION. MAXIMUM EXTERIOR(+) LOAD PER :AMB - (9.33' X 50 PSF)/2 = 233.3 Lbs par Ft. MAXIMUM INTERIOR(-) LOAD PER JAMB = (9.33 X 60 PSF)/2 = 279.9 Lbs per FL STEEL STRUCTURE EY OTHERS MUST SUPFORT THE LOADS IMPOSED BY DOOR SYSTEM 5/16" CIA. BOLTS WITH WASHER do NUT AT 12" O.C. I=. ANCHOR SPACING ANCHORS I STRUCTURE I EMBED SPACING EDGE DIST. 3 8 HLC SLEEVE BY ,IU' CONC. 1-1 4"=8-2-1 3 8" HLC SLEEVE 13Y :41LTI' BOCK 1-1 4"1. 3 8- DYNASOLT BY 'ITW CONC. 1-1 2" 3 B" DYNAEOLT BY 'ITW' FILLED BLOCK 1-1 23 8 POWER -BOLT BY 'POl9ER5 CONC. 2-3 d SLEEVE -ALL BY MPSONS CON'C. 1-1 2 CONCRETE f c = 3000 PSI MIN. C-90 GROUT FILLED BLOCK f'm - 2C00 FSI MIN. 1-1//C X 2-1/2' X to GA 1-1/2" CONL: STEEL ANGLE 1-1/2' 12 GA. GALV. STEEL Mi BRACKETS f3" LONG 2AY S X 1' % 14 GA AT 12" O.C. IN DOOR OPNG. GA_ .STEEL TRACK AT 18" O.C. ABOVE DOOR OPNG. FASTENED TO TRACK PLATES CONNECTED TO cc MT. ANGLE SLOTTED 1MS. & LOCK TN H0. W/ (3) SPOT WELDS AT EACH SIDE RFVFRSFTRA TRACK GQY.:INU.C.US_ANGLE_IEAGK TO Sg[L 70 CONGRETF ANn FI Fp B O x ALTERNATE TRACK INSTALLATION PRODUCT RENEWED as complying the Florida Building Code .CI 115-0330.02 Expiration te0810912021 By MI—F- Product Control 0 0 O r0 W n i¢ ¢-j UF- + Z~z� (n m p r O 03�� U Op Z=u> till Atli n unh A?I�lllq��i = 3 ME OPT drawing no. O1 09 'EG DOOR PANEL 24 GA (.024) STEEL MN. 110' DIA. WASHER {8 X 3/4' SUS 0 3/8' FROM ENDS AND 7' O.C. MAX. —(4) g6 X 3/4' SMS 1I0 1-3/8- FROM ENDS A140 6-1/2' O.C. MAX. 175 X .062 DEEP GROCVE 1/4' POLYCARBONATE LEXAN gY 'SABIC INNOVATIVE PLASTICS' NCA #15-0915.08 .062 DEEP $6 X 3/4' sus 1-3/8' FROM ENDS 10 6-1/2" O.C. MAX �#8 X-3/4' SMS ® 3/8' FROM ENDS \ AND 7' O.C. MAX. `7/16' DIA WASHER DOOR PANEL 24 GA. (.024) STEEL MIN. * PLASTIC COMPLIES WITH CHAPTER 26 OF FBC SEE EVIDENCE PAGE 21 3/4' MAX. 14DW. WIDTH r o o MAX. j .500 .250 [] _ -9 O I Z ;:- 1.765 1.725 u 5 0g a IL W OD I I�.eoo Clomm Q o o �— .176 a p * EXTERIOR FRAME * INTFRIOR FRAME o m z o I RIGID PVC ONE PIECE INJECTION RIGID PVG ONE PIECE INJECTION � up] y fi IR Ijjl I .1 at to a Q W S m ED m INSIDE ELEVATION RAISED PANEL EMBOSSED DOOR WITH OPTIONAL WINDOWS C WINDOW LITES CAN BE IN ANY LOCATION IN DOOR SECTION ye x a/a' sus ® 3/8' FROM ENDS .175 X .062 DEEP AND 4-1/2. O.C. MAXI GROOVE � I PRODUCT RENEWED as complying with the Florida ----- - Building Code -- - NOA-No. 1"330.02 DOOR PANEL j EXTERIOR Expiration D 0010912021. 24 GA (.024) STEEL MIN. 15/16�-MIN. O.L On. BY GLAZING BITE mlam Product Control WINDOW WIDTH a:I � O o O M Ldco Q Zcoz Z m U3Gin I o 03�y U O Z al j O N � G i 0 o�s�'@ EnSSSp' -�0, i 33 = ti drawing no. 01-09 sheet 17 MMAW MIAMI-DADE COUNTY E PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.niiamidade.gov/economv Owens Corning Roofing and Asphalt, LLC One Owens Corning Parkway Toledo, OH 43659 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Duration®, Duration® Premium, TruDefinition® Duration®, and TruDefinition® Duration® Designer Colors Collection LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA No. 12-0309.01 and consists of pages 1 through 6. The submitted documentation was reviewed by Gaspar J Rodriguez. NOA No.: 16-0425. l Expira tR]a e• '7 19�2'1�App o e: Y`2 h Page 1 of Page 12 of 17 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub -Category: Asphalt Shingles Materials: Laminate ' Deck Type: Wood SCOPE This approves a roofing system using Owens Corning Duration® and Duration® Premium asphalt shingles manufactured by Owens Corning as described in Section 2 of his Notice of Acceptance. PRODUCT DESCRIPTION Product Dimensions Test Specifications Product Description Duration® 13 `/4" x 39 3/s" Manufacturing Locations #1, 2 Duration® Premium; 13 ``/4" x 39 3/8" TruDefinition® Duration®; TruDefinition® Duration® Designer Colors Collection Manufacturing Location #1, 2, 3, 4 Duration® 13 `/4" x 39 3/8" Manufacturing Location #1, 2, 3 Duration® Premium; 13 `/4" x 39 3/8" TruDefinition® Duration®; TruDefinition® Duration® Designer Colors Collection Manufacturing Location #1, 2, 3, 4 MANUFACTURING LOCATION 1. Jacksonville, FL 2. Memphis, TN 3. Savannah, GA 4. Irving, TX TAS 110 A heavy weight, fiberglass reinforced four tab asphalt shingle with continuous bead of sealant. TAS 110 A heavy weight, fiberglass reinforced four tab asphalt shingle with large nail area with continuous bead of sealant. TAS 110 A heavy weight, fiberglass reinforced four tab asphalt shingle with dashed bead of sealant. TAS 110 A heavy weight, fiberglass reinforced four tab asphalt shingle with dashed bead of sealant. NOA No.: 16-0425.01 MMMIOADE COUNTY Expiration Date: 07/19/21 �Fnayxfyn� Approval Date: 07/21/16 Page 2 of 6 Page 13 of 17 EVIDENCE SUBMITTED Test Agency Test Identifier Test Name/Report Date PRI Asphalt Technologies, Inc. OCF-157-02-01 TAS 100 10/26/10 OCF-102-02-01 TAS 100 11/12/07 OCF-156-02-01 TAS 100 10/26/10 OCF-163-02-01 TAS 100 12/10/10 OCF-164-02-01 TAS 100 12/10/10 OCF-098-02-01 TAS 100 02/22/07 OCF-099-02-01 TAS 100 02/26/07 OCF-102-02-01 TAS 100 11/12/07 OCF-172-02-01 TAS 100 05/26/11 OCF-179-02-01 TAS 100 02/02/12 Underwriters Laboratories, Inc. 07CA39536 TAS 107 11/11/07 03NK04954 TAS 107 03/28/03 03NK04954 TAS 107 03/11/03 IONK13947 TAS 107 11/12/10 11CA15662 TAS 107 05/27/11 11NB21712 TAS 107 02/18/12 07CA02026 ASTM D 3462 01/26/07 12CA12180 ASTM D 3462 03/01/12 LIMITATIONS 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Shall not be installed on roof mean heights in excess of 33 ft. 3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. INSTALLATION 1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115. 2. Flashing shall be in accordance with Roofing Application Standard RAS 115 3. The manufacturer shall provide clearly written application instructions. 4. Exposure and course layout shall be in compliance with Detail 'A', attached. 5. Nailing shall be in compliance with Detail 'B', attached. LABELING 1. Shingles shall be labeled with the Miami -Dade Seal as seen below, or the wording "Miami -Dade County Product Control Approved". NOA No.: 16-0425.01 Pjira ' n Date: 07/19/21 p al 07%�1/16 P' e31of6 Page 14 0 1 BUILDING PERMIT REQUIREMENTS Application for building permit shall be accompanied by copies of the following: 1.1 This Notice of Acceptance. 1.2 Any other documents required by the Building Official or the applicable code in order to properly evaluate the installation of this system. DETAIL A FIRST 1 QMLAMMI-D�ADE COUNTY .. NOA No.: 16-0425.01 Expiration Date: 07/19/21 Approval Date: 07/21/16 Page 4 of 6 Page 15 of 17 DETAIL B DURATION & TRUDEFINITION® DURATION® (SEALANT MAY BE CONTINUOUS OR DASHED. NOT SHOWN IN THE DETAIL DRAWINGS) �cop1y my m v 0. �. m U3 m m o.0v o m N0 W 'D G1 W 7 N G1 a d MIAMI•DADE COUNTY D co m c m m Z m d. N T O p N cn D. C fD ca Z N NOA No.: 16-0425.01 Expiration Date: 07/19/21 Approoa � a 0 07 f21/T6 tNiggW06"`7 a7 MUM , 4, r MAXIMUM SLOPE 21:12 SLOPE GREATER THAN 21:12 END OF THIS ACCEPTANCE NOA No.: 16-0425.01 Expiration Date: 07/19/21 Approval Date: 07/21/16 Page 6 of 6 Page 17 of 17