Loading...
HomeMy WebLinkAboutProject Information- wrightsofts Project Summary Entire House WebREPS, LLC Job: 7508 Coquina Avenue Date: June 28, 2017 By: Josh Putman Plan: 7508 Coquina Avenue 1892 Commerce Avenue, Vero Beach, FL 32960 Phone: 800-810-3280 Fax 888-971-2999 Email: sales@webrepshvac.com Web: www.webrepsv4holesale.com License: CAC0547... For: Joe Gianna, Habitat for Humanity 2904 Okeechobee Road, Ft. Pierce, FL 34947 Phone: 772-460-6336 - Notes: 7508 Coquina Avenue Port St. Lucie FI Design Information Weather: Vero Beach Muni, FL, US Winter Design Conditions Outside db 43 OF Inside db 70 OF Design TD 27 OF Heating Summary Structure 11799 Btuh Ducts 3012 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 14811 Btuh Infiltration Method Simplified Construction quality Semi -tight Fireplaces 0 nolin He1200 Co Area (ft2) 1200 Volume (ft') 9597 9597 Air changes/hour 0.31 0.16 Equiv. AVF (cfm) 50 26 Heating Equipment Summary Make Goodman Trade Heat Strip Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 8.0 kW 27297 Btuh 27 OF 933 cfm 0.063 cfm/Btuh 0.60 in H2O Summer Design Conditions Outside db 91 OF Inside db 75 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 59 gr/lb Sensible Cooling Equipment Load Sizing Structure 12730 Btuh Ducts 5156 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 1707 Btuh Use manufacturer's data Rate/swing multiplier Equipment sensible load 1.00 19593 Btuh Latent Cooling Equipment Load Sizing Structure 5432 Btuh Ducts 1404 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 6836 Btuh Equipment Total Load (Sen+Lat) 26429 Btuh Req. total capacity at 0.70 SHR 2.3 ton Cooling Equipment Summary Make Goodman Mfg. Trade GOODMAN Cond GSX160301F Coil ASPT36C14A AHRI ref 5756174 Efficiency 13.0 EER, 16 SEER Sensible cooling 19600 Btuh Latent cooling 8400 Btuh Total cooling 28000 Btuh Actual air flow 933 cfm Air flow factor 0.052 cfm/Btuh Static pressure 0.60 in H2O Load sensible heat ratio 0.74 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2017-Jun-28 13:00:59 wrightsoft° Right -Suite® Universal 2017 17.0.23 RSU16998 Page 1 ACiCK ...abitat for Humanity PSLV508 Coquina Avenue.rup Calc = MJ8 Front Door faces: S Sheet 1 8x4 mclst 21 cfm 10x6 4 160 cfm Master _ 7 "/ ---N 8x10 10" c lst 3 33 cfm 4" 8' 1 Bath 1 10 x 6 Hall 12 " 107 cfm 1r Laundry Rm R ' 5" 18" Fbath 8 x 4 20 x 20 65 cfm r , n 933 cfm ,,.� , \ ' 8 x 4 27 cfm 10x6 7" 157 cfm Kitchen Garage Bed 2 7" 10x6 / / 148 cfm Bed 3 7" 10x6 163 cfm Dining Rm 8" Living Rm 6' 6' 10x6 10x6 120 cfm 120 cfm Job #: 7608 Coquina Avenue WebREPS, LLC Scale: 1 : 85 Performed by Josh Putman for: Page 1 Joe Gianna 1892 Commerce Avenue NghtSuite®Universal 2017 2904 Okeechobee Road Vero Beach, FL 32960 17.0.23 RSU16998 Ft. Pierce, FL 34947 Phone: 800-810-3280 Fax: 888-971 2999 2017-Jun-2813:01:28 Phone:772-460-6336 wwwwebrepswholesale.com sales@webrepshvac.com-nity PSL\7508 Coquina Avenue.rup r Duct System Summary Job: 7508 Coqu Ina Avenue + ' Wrightsoft° y Date: June 28, 2017 Entire House By: Josh Putman WebREPS, LLC Plan: 7508 Coquina Avenue 1892 Commerce Avenue, Vero Beach, FL 32960 Phone: 800-810-3280 Fax 888-971-2999 Email: sales@vebrepshvac.com Web: www.webrepswholesale.com License: CAC0547... For: Joe Gianna, Habitat for Humanity 2904 Okeechobee Road, Ft. Pierce, FL 34947 Phone: 772-460-6336 External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.60 in H2O 0.24 in H2O 0.36 in H2O 0.227 / 0.133 in H2O 0.079 in/100ft 933 cfm Cooling 0.60 in H2O 0.24 in H2O 0.36 in H2O 0.227 / 0.133 in H2O 0.079 in/100ft 933 cfm 458 ft Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk Bath 1 h 516 33 16 0.087 4.0 OX 0 VIFX 21.3 240.0 st2 Bath 2 c 525 3 27 0.088 4.0 OX 0 VIFX 19.4 240.0 st2 Bed 2 h 2345 148 97 0.097 7.0 Ox 0 VIFx 15.0 220.0 st3 Bed c 2042 88 107 0.093 6.0 Ox0 VIFx 14.0 230.0 st4 Dining Rm c 3117 90 163 0.093 7.0 Ox 0 VIFX 15.3 230.0 st4 Kitchen C 3016 84 157 0.086 7.0 Ox 0 VIFX 23.9 240.0 st2 Laundry Rm h 1040 65 34 0.086 5.0 OX 0 VIFx 19.6 245.0 st2 LivingRm h 1908 120 102 0.079 6.0 Ox0 VIFx 39.6 250.0 st5 Living Rm-A h 1908 120 102 0.079 6.0 OXO VIFx 39.0 250.0 st5 Master h 2542 160 119 0.100 7.0 OX 0 VIFX 11.9 215.0 st3 mclst h 329 21 9 0.100 4.0 Ox 0 VIFX 13.3 215.0 st3 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st5 Peak AVF 240 205 0.079 689 8.0 0 x 0 VinIFIX st4 st1 Peak AVF 933 933 0.079 746 14.8 10 x 18 RectFbg st4 Peak AVF 419 474 0.079 603 12.0 0 x 0 VinlFlx st1 st2 Peak AVF 186 235 0.086 672 8.0 0 x 0 VinlFix st1 st3 Peak AVF 329 225 0.097 602 10.0 0 x 0 VinlFix st1 „. + wrightSOft° Right -Suite® Universal 2017 17.0.23 RSU16998 AC rV k ...abitat for Humanity PSL17508 Coquina Avenue.rup Calc = MJ8 Front Door faces: S 2017-Jun-28 13:00:59 Page 1 Return Branch Detail Table Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 Ox0 933 933 168.7 0.079 528 18.0 Ox 0 VIFx rt1 Name Trunk Type Htg (cfm) Clg (cfm) Design FIR Veloc (fpm) Diam (in) H x W (in) Duct Material Trunk rt1 PeakAVF 933 933 0.079 467 14.8 16 x 18 RectFbg A wrightSOft° Right -Suite® Universal 2017 17.0.23 RSU16998 ACCA ...abitat for Humanity PSL\7508 Coquina Avenue.tup Calc = MJ8 Front Door faces: S 2017-Jun-28 13:00:69 Page 2