Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutProject Information- wrightsofts Project Summary
Entire House
WebREPS, LLC
Job: 7508 Coquina Avenue
Date: June 28, 2017
By: Josh Putman
Plan: 7508 Coquina Avenue
1892 Commerce Avenue, Vero Beach, FL 32960 Phone: 800-810-3280 Fax 888-971-2999 Email: sales@webrepshvac.com Web: www.webrepsv4holesale.com License: CAC0547...
For: Joe Gianna, Habitat for Humanity
2904 Okeechobee Road, Ft. Pierce, FL 34947
Phone: 772-460-6336
- Notes: 7508 Coquina Avenue Port St. Lucie FI
Design Information
Weather: Vero Beach Muni, FL, US
Winter Design Conditions
Outside db 43 OF
Inside db 70 OF
Design TD 27 OF
Heating Summary
Structure 11799 Btuh
Ducts 3012 Btuh
Central vent (0 cfm) 0 Btuh
(none)
Humidification 0 Btuh
Piping 0 Btuh
Equipment load 14811 Btuh
Infiltration
Method
Simplified
Construction quality
Semi -tight
Fireplaces
0
nolin
He1200
Co
Area (ft2)
1200
Volume (ft')
9597
9597
Air changes/hour
0.31
0.16
Equiv. AVF (cfm)
50
26
Heating Equipment Summary
Make Goodman
Trade Heat Strip
Model
AHRI ref
Efficiency
Heating input
Heating output
Temperature rise
Actual air flow
Air flow factor
Static pressure
Space thermostat
100 EFF
8.0
kW
27297
Btuh
27
OF
933
cfm
0.063
cfm/Btuh
0.60
in H2O
Summer Design Conditions
Outside db
91 OF
Inside db
75 OF
Design TD
16 OF
Daily range
L
Relative humidity
50 %
Moisture difference
59 gr/lb
Sensible Cooling Equipment Load Sizing
Structure
12730
Btuh
Ducts
5156
Btuh
Central vent (0 cfm)
0
Btuh
(none)
Blower
1707
Btuh
Use manufacturer's data
Rate/swing multiplier
Equipment sensible load
1.00
19593
Btuh
Latent Cooling Equipment Load Sizing
Structure
5432
Btuh
Ducts
1404
Btuh
Central vent (0 cfm)
0
Btuh
(none)
Equipment latent load
6836
Btuh
Equipment Total Load (Sen+Lat) 26429 Btuh
Req. total capacity at 0.70 SHR 2.3 ton
Cooling Equipment Summary
Make Goodman Mfg.
Trade GOODMAN
Cond GSX160301F
Coil ASPT36C14A
AHRI ref 5756174
Efficiency 13.0 EER, 16 SEER
Sensible cooling
19600
Btuh
Latent cooling
8400
Btuh
Total cooling
28000
Btuh
Actual air flow
933
cfm
Air flow factor
0.052
cfm/Btuh
Static pressure
0.60
in H2O
Load sensible heat ratio
0.74
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2017-Jun-28 13:00:59
wrightsoft° Right -Suite® Universal 2017 17.0.23 RSU16998 Page 1
ACiCK ...abitat for Humanity PSLV508 Coquina Avenue.rup Calc = MJ8 Front Door faces: S
Sheet 1
8x4 mclst
21 cfm
10x6 4
160 cfm
Master _
7 "/
---N
8x10
10"
c
lst 3
33 cfm
4" 8'
1
Bath 1 10 x 6
Hall
12 "
107 cfm
1r
Laundry Rm R '
5" 18"
Fbath
8 x 4 20 x 20
65 cfm r , n
933 cfm
,,.� , \ '
8 x 4
27 cfm
10x6
7"
157 cfm
Kitchen
Garage
Bed 2
7" 10x6
/ / 148 cfm
Bed 3
7"
10x6
163 cfm
Dining Rm
8"
Living Rm
6' 6'
10x6 10x6
120 cfm 120 cfm
Job #: 7608 Coquina Avenue WebREPS, LLC Scale: 1 : 85
Performed by Josh Putman for: Page 1
Joe Gianna 1892 Commerce Avenue NghtSuite®Universal 2017
2904 Okeechobee Road Vero Beach, FL 32960 17.0.23 RSU16998
Ft. Pierce, FL 34947 Phone: 800-810-3280 Fax: 888-971 2999 2017-Jun-2813:01:28
Phone:772-460-6336 wwwwebrepswholesale.com sales@webrepshvac.com-nity PSL\7508 Coquina Avenue.rup
r
Duct System Summary Job: 7508 Coqu Ina Avenue
+ ' Wrightsoft° y Date: June 28, 2017
Entire House By: Josh Putman
WebREPS, LLC Plan: 7508 Coquina Avenue
1892 Commerce Avenue, Vero Beach, FL 32960 Phone: 800-810-3280 Fax 888-971-2999 Email: sales@vebrepshvac.com Web: www.webrepswholesale.com License: CAC0547...
For: Joe Gianna, Habitat for Humanity
2904 Okeechobee Road, Ft. Pierce, FL 34947
Phone: 772-460-6336
External static pressure
Pressure losses
Available static pressure
Supply / return available pressure
Lowest friction rate
Actual air flow
Total effective length (TEL)
Heating
0.60
in H2O
0.24
in H2O
0.36
in H2O
0.227 / 0.133
in H2O
0.079
in/100ft
933
cfm
Cooling
0.60
in H2O
0.24
in H2O
0.36
in H2O
0.227 / 0.133
in H2O
0.079
in/100ft
933
cfm
458 ft
Name
Design
(Btuh)
Htg
(cfm)
Clg
(cfm)
Design
FR
Diam
(in)
H x W
(in)
Duct
Matl
Actual
Ln (ft)
Ftg.Egv
Ln (ft)
Trunk
Bath 1
h 516
33
16
0.087
4.0
OX 0
VIFX
21.3
240.0
st2
Bath 2
c 525
3
27
0.088
4.0
OX 0
VIFX
19.4
240.0
st2
Bed 2
h 2345
148
97
0.097
7.0
Ox 0
VIFx
15.0
220.0
st3
Bed
c 2042
88
107
0.093
6.0
Ox0
VIFx
14.0
230.0
st4
Dining Rm
c 3117
90
163
0.093
7.0
Ox 0
VIFX
15.3
230.0
st4
Kitchen
C 3016
84
157
0.086
7.0
Ox 0
VIFX
23.9
240.0
st2
Laundry Rm
h 1040
65
34
0.086
5.0
OX 0
VIFx
19.6
245.0
st2
LivingRm
h 1908
120
102
0.079
6.0
Ox0
VIFx
39.6
250.0
st5
Living Rm-A
h 1908
120
102
0.079
6.0
OXO
VIFx
39.0
250.0
st5
Master
h 2542
160
119
0.100
7.0
OX 0
VIFX
11.9
215.0
st3
mclst
h 329
21
9
0.100
4.0
Ox 0
VIFX
13.3
215.0
st3
Trunk
Htg
Clg
Design
Veloc
Diam
H x W
Duct
Name
Type
(cfm)
(cfm)
FR
(fpm)
(in)
(in)
Material
Trunk
st5
Peak AVF
240
205
0.079
689
8.0
0 x 0
VinIFIX
st4
st1
Peak AVF
933
933
0.079
746
14.8
10 x 18
RectFbg
st4
Peak AVF
419
474
0.079
603
12.0
0 x 0
VinlFlx
st1
st2
Peak AVF
186
235
0.086
672
8.0
0 x 0
VinlFix
st1
st3
Peak AVF
329
225
0.097
602
10.0
0 x 0
VinlFix
st1
„. + wrightSOft° Right -Suite® Universal 2017 17.0.23 RSU16998
AC rV k ...abitat for Humanity PSL17508 Coquina Avenue.rup Calc = MJ8 Front Door faces: S
2017-Jun-28 13:00:59
Page 1
Return Branch Detail Table
Name
Grille
Size (in)
Htg
(cfm)
Clg
(cfm)
TEL
(ft)
Design
FIR
Veloc
(fpm)
Diam
(in)
H x W
(in)
Stud/Joist
Opening (in)
Duct
Matl
Trunk
rb1
Ox0
933
933
168.7
0.079
528
18.0
Ox 0
VIFx
rt1
Name
Trunk
Type
Htg
(cfm)
Clg
(cfm)
Design
FIR
Veloc
(fpm)
Diam
(in)
H x W
(in)
Duct
Material
Trunk
rt1
PeakAVF
933
933
0.079
467
14.8
16 x 18
RectFbg
A wrightSOft° Right -Suite® Universal 2017 17.0.23 RSU16998
ACCA ...abitat for Humanity PSL\7508 Coquina Avenue.tup Calc = MJ8 Front Door faces: S
2017-Jun-28 13:00:69
Page 2