HomeMy WebLinkAboutSite Plan3" VTR AL - - 2„ 2" TUB y - - 2" VTR L _1L WC i�. W TUB - C 4" AIR GAP 2" S 3" 4" DW 2 Go 4 PLUMBING RISER SCALE: N.T.S. 4" 4" TO S.S. IF LUMBING NOTES: 1. ALL WORK SHALL BE IN ACCORDANCE WITH THE FBC 2014 - PLUMBING. 2. DWV PIPING SHALL BE SCHEDULE 40 PVC. 3. WATER PIPING IN BUILDING SHALL BE ONE OF THE FOLLOWING: TYPE L COPPER, CPVC, OR PEX. 4. SLEEVE ALL PIPING IN CONTACT WITH CONCRETE OR UNDERGROUND WITHIN BUILDING. 5. HOT WATER PIPING WITH A MINIMUM THERMAL RESISTANCE OF R-3 SHALL BE APPLIED TO PIPING LARGER THAN 3/4" NOMINAL DIAMETER; PIPING FROM WATER HEATER TO KITCHEN OUTLETS, PIPING LOCATED OUTSIDE THE CONDITIONED SPACE, PIPING FROM THE WATER HEATER TO THE DISTRIBUTION MANIFOLD, PIPING LOCATED UNDER THE FLOOR SLAB, BURIED PIPING, SUPPLY AND RETURN PIPING IN RECIRCULATION SYSTEMS, PIPING WITH RUN LENGTHS GREATER THAN 20 FEET. 6. WATER HEATERS INSTALLED SHALL BE IN ACCORDANCE WITH FBC 2014 ENERGY CONSERVATION NOTES: 1. THE CONTRACTOR, SUBCONTRACTOR, SUPPLIER, ETC. SHALL VERIFY ALL DIMENSIONS, CONDITIONS AT JOB SITE, PLANS, SPECIFICATIONS, ETC. 2. STRUCTURAL FEATURES NOT DETAILED ON THESE PLANS WILL BE ADDRESSED BY THE ENGINEER AS CONSTRUCTION PROGRESSES. 3. ALL WRITTEN DIMENSIONS ON THESE DRAWINGS TAKE PRECEDENCE OVER SCALED DIMENSIONS. 4. ALL CONSTRUCTION MUST COMPLY WITH THEFLORIDA BUILDING CODE (FBC) 2014, FBC 2014 RESIDENTIAL, FBC 2014 PLUMBNG CODE, FBC 2014 MECHANICAL CODE, FBC 2014 ENERGY CONSERVATION, AND THE NEC (NFPA 70) 2011 EDITION. 5. RESIDENCE LOCATED IN NEGLIGIBLE WEATHERING AREA, AND IN VERY HEAVY TERMITE INFESTATION AREA PER FRC301. STRUCTURAL NOTES: 26'-4" O O 1. DESIGN LOADS IN ACCORDANCE WITH ASCE740. 2. SOIL BEARING CAPACITY: 2500 PSF (MIN.). 3. ALL STRUCTURAL CONCRETE IN BEAMS, LINTELS, VERTICAL CELLS, AND 3' 4" COLUMNS SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI COMPRESSIVE STRENGTH AT 28 DAYS. 4. SLAB/FOOTINGS TO BE CONCRETE WITH A MINIMUM 2500 PSI COMPRESSIVE O� X r STRENGTH AT 28 DAYS. SEE PLAN FOR SIZES& STEEL REQUIREMENTS. O v 5. MINIMUM CONCRETE PROTECTION FOR REINFDRCING BARS: FOOTINGS: 3" do BEDROOM #2 BEAMS: 1-1/2" SUSPENDED SLABS: 1-1/2". o 10' - 6" X 10' - 0" 6. LAP ALL REINFORCING STEEL A MINIMUM OF BAR DIAMETERS EXCEPT AS MASTER BEDROOM NOTED GRADE 60 STEEL MINIMUM IN BEAMS AJD COLUMNS. 12' - 6" X 11' - 4" 7. ALL LUMBER IN CONTACT WITH CONCRETE ORMASONRY SHALL BE O O PRESSURE TREATED. 8. SPLITTING OR CRACKING OF STRUCTURAL CO'APONENTS DUE TO INSTALLATION OF HARDWARE IS NOT PERMITTED. 5'-2" 9. UNLESS OTHERWISE NOTED, THE INSTALLATIW OF SPECIFIED HARDWARE 8 SHALL CONFORM TO THE MANUFACTURES IN:TRUCTIONS AND STANDARD CLOSET CLOSET O 2-0"X 2'-0"X4'-10 PRACTICES. _ 4'- 10" 10. UNLESS OTHERWISE NOTED, ROOF SHEATHIN3 TO BE NAILED WITH 8d O RING -SHANK NAILS @ 4" O.C. PERIMETER AND i" O.C. FIELD. 40" X 40" BATHROOM #1 11. UNLESS OTHERWISE NOTED FOR EXTERIOR VALLS, EXTERIOR PLYWOOD A/C PAD 14' - 4" X 13' - 4 O SHEATHING AND INTERIOR DRYWALL IS TO BENAILED WITH 10d OR BETTER NAILS 6" O.C. EDGES, AND 6" O.C. FIELD, ORSOREWED WITH DRYWALL0 SCREWS 1.5" LONG AND 0.131 DIA. O o 0 12. LINTELS SHALL HAVE A MINIMUM 4" BEARING JXCEPT RECESSED LINTELS BEDROOM #3 SHALL HAVE 8" BEARING. O 0 10'-6"X10'-0" 13. PROVIDE #5 CORNER BARS W/30" MIN. LAP SPICE FOR BOND BEAM. EWH O 14. STUCCO SOFFIT NOTE: SOFFIT TO BE STUCCO OVER WIRELATH W/ 11 GA. 2" 1 v NAILS W/ 3/8" 0 HEAD @ 6" O.C. OVER 3/8" ME_RL RIB LATH @ 6" O.C. W/ (2 36" X 62" LEVEL LAYERS OF 15# FELT OVER EACH FRAMING MEMBER _--LAUNDRY T" LANDING CENTERED ON DOOR WALL FINISH / INSULATION NOTES: ACCESS x oM 4- 1 . INTERIOR TO BE 1/2" DRYWALL FINISH. 6'-1I0" 14'-2" .. _ ..,,,..... 2. ALL INTERIOR GYPSUMBCARD T�e19�7HfeKmW{TH . n" -. _r... (43 ^" , - 1I1IiI WASHER i - _ _- LONG, 19/64" HEAD; 0.098" DIAMETER, 1-1/4" L NG; ANNULAR -RINGED; 5d DRYER OPENING 4'-2" - i COOLER NAIL, 0.086" 0, 1-5/8" LONG, 15/64" HEz OR GYPSUM BOARD NAIL, 0.086"0, 1-5/8" LONG, 9/32" HEAD) SPACED AT r O.C. FOR NAILS AND 12" O.C. PANTRY FOR SCREWS. `D 01 01 EO� DINI G ROOM O op 3. WALLS AT SHOWER TO BE TILE. PROVIDE CEMENT, FIBER -CEMENT OR GLASS 13' - " X 16' - 4" zn MAT GYPSUM BACKERS IN COMPLIANCE WITFIASTM C 1288, C 1325, C 1178, DW OR C 1278 AND INSTALLED IN ACCORDANCE FAITH MANUFACTURERS' - RECOMMENDATIONS AS BACKERS FOR WALL FILE IN TUB AND SHOWER AREAS AND WALL PANELS IN SHOWER AREAS (PER FRC 702.4.1 & FRC ' O ° KITCHEN 702.4.2) FOOTAGE 4. WALL AND CEILING FINISHES SHALL HAVE A SMOKE -DEVELOPED INDEX OF N 9'-10"X10,_4... NOT GREATER THAN 450. 5. WALL AND CEILING FINISHES SHALL HAVE A FLAME -SPREAD CLASSIFICATION 2. FT. OF NOT GREATER THAN 200. N 1201 S.F. 6. ALL EXPOSED INSULATION MATERIALS INSTAILED ON ATTIC FLOORS SHALL , N 209 S.F. HAVE A CRITICAL RADIANT FLUX NOT LESS TIAN 0.12 WATT PER SQUARE F7771[;101-10" REFRIG. I CENTIMETER. EXPOSED FOAM PLASTIC INSULATION MATERIALS EXPOSED OPENING LIVINGROOM- 135S.F. TO THE UNDERSIDE OF THE ROOF DECK OR Gl THE ATTIC WALLS SHALL ' ' 13, _ 8,, 14' _ 8„ 1544 S.F. COMPLY WITH SECTION FRC 316. - 7. PER FRC 702.2.1 ALL GYPSUM BOARD MATERILS AND ACCESSORIES SHALL CONFORM TO ASTM C 36, C 79, C 475, C 514, 0630, C 931, C 960, C 1002, C O INSULATE 9608 CU. FL 1047, C 1177, C 1178, C 1278, C 1395, C 1396, Ot C 1658 AND SHALL BE INTERIOR INSTALLED IN ACCORDANCE WITH THE PRONSIONS OF FRC, AND ADHESIVES L "A" GARAGE FOR THE INSTALLATION OF GYPSUM BOARD3HALL CONFORM TO ASTM C 557. 200A MLO WALL W/ R-11 8. INSULATION MATERIALS, INCLUDING FACING, SUCH AS VAPOR RETARDERS OR VAPOR PERMEABLE MEMBRANES INSTA LED WITHIN FLOOR -CEILING 164" ASSEMBLIES, ROOF -CEILING ASSEMBLIES, VALL ASSEMBLIES, CRAWL SPACES AND ATTICS SHALL HAVE A FLAME TREAD INDEX NOT TO EXCEED 25 WITH AN ACCOMPANYING SMOKE-DEVELWED INDEX NOT TO EXCEED 450 WHEN TESTED IN ACCORDANCE WITH ASTM: 84 OR UL 723. GARAGE ;o 20'-0"X18,_0„ ENERGY CONSERVATIO4 NOTES: O ---------- DOOR & WINDOW SCHEDULE SYM. ITEM OPENING DESIGN PRESSURES PRODUCT RATED DESIGN PRESSURES MANUFACTURER MODEL N0. PRODUCT APPROVAL NUMBER GLASS TYPE 1 2868 INTERIOR DOOR ±70 O 3068 SEC. DOOR SEE ELEV'S - ± 67 THERMA-TRU SMOOTH STAR FL#5891.2 3 5068 SGD SEE ELEV'S ± 65 CUSTOM WINDOW SYST. SGD-8920 FL#10272.1 IMPACT 4 SH 22 SEE ELEV'S ± 70 CUSTOM WINDOW SYST. SH-8100 FL#16177.1 IMPACT 5O SH 25 (EGRESS) SEE ELEV'S ± 70 CUSTOM WINDOW SYST. SH-8100 FL#16177.1 IMPACT 6 SH 35 SEE ELEV S ± 70 CUSTOM WINDOW SYST. SH-8100 FL#16177.1 IMPACT 7 1068 INTERIOR BIFOLD DOOR 8 4068 INTERIOR BIFOLD DOOR 9 2868 POCKET DOOR 10 8' W X T H GARAGE DOOR SEE ELEV'S +50 / -60 DAB 824 / 811 `" NOA# 16-0330.02 ROOFING MATERIAL Vult = 160 MPH Vult = 194 MPH OWENS CORNING SHINGLES NOA# 16-0425.01 1. RESIDENCE SHALL BE IN ACCORDANCE WITF'FLORIDA BULDING CODE 2014 ENERGY CONSERVATION RESIDENTIAL. 2. ATTIC ACCESS DOORS OR HATCHES FROM C)NDITIONED SPACES TO COVERED PORCH 6' - 0" X 16' - 0" UNCONDITIONED SPACES SHALL BE WEATHIRSTRIPPED AND INSULATED TO A LEVEL EQUIVALENT TO THE INSULATION 01 THE SURROUNDING SURFACES, -0BL 2X12 A WOOD FRAMED OR EQUIVALENT BAFFLE a RETAINER IS REQUIRED TO BE WOOD BEAM (TMP.) PROVIDED WHEN LOOSE FILL IS INSTALLED,'O PREVENT LOOSE FILL FROM SPILLING INTO THE LIVING SPACE. I 10 3. THE BUILDING THERMAL ENVELOPE SHALL BI CONSTRUCTED TO LIMIT AIR LEAKAGE IN ACCORDANCE WITH THE REQUIFE_MENTS R402.4.1 THROUGH 4'-8 - -� 4. THE BUILDING SHALL BE TESTED FOR AIR LEIKAGE IN ACCORDANCE WITH f' 26'4" R402.4.1.2. 5. WINDOWS, SKYLIGHTS, AND SLIDING GLASS IOORS SHALL HAVE AN AIR INFILTRATION RATE OF NO MORE THAN 0.3 GM PER SQUARE FT, AND SWINGING DOORS NO MORE THAN 0.5 CFM PER SQUARE FT, AND MUST BE TESTED, LISTED, AND LABELED IN ACCORDAFCE WITH R402.4.3. 6. CONTRACTOR SHALL PROVIDE ENERGY PERIORMANCE LEVEL (EPQ DISPLAY CARD IN ACCORDANCE WITH FBC 2014 ENERGY CONSERVATION R401.3. FLOOR PLAN A _U SCALE: N.T.S. THESE DOCUMENTS CONTAIN ARCHITECTURAL SYMBOLS USED FOR GRAPHIC PURPOSES ONLY. SIZE AND LOCATION MAY VARY TO MEET MANUFACTURER'S SPECIFICATIONS. DO NOT SCALE DRAWINGS. PLEASE CONTACT DESIGNER WITH ANY QUESTIONS REGARDING DIMENSIONS. ENGINEERING LICENS ". .; a " { p SERIAL 4: 3B BC A2 2100 ODDO 004C 1287 DF PROJECT NUMBER: HFH - 1200 REVISIONS: DESCRIPTION DATE BY RE CONSTRUCTION DRAWINGS 04/26/17 AG A REV ELEC. SERVICE 07/05/17 AG B CABINET DETAILS/ SITE PLAN 08/10/2017 AG C ADDED VOLUME UNDER AIR 08/17/2017 AG D SITE NAME: 7508 COQUINA AVE PROJECT: xll 8TOTBI SITE ADDRESS: 7508 COQUINA AVE. FORT PIERCE, FL 34951 F1IVI\. -_... FLOOR PLAN