Loading...
HomeMy WebLinkAboutTrussr 4190�A ROOF ==TRUSSES A•FLORIDA CORPORATION Lumber design values are in accordance with ANSI/TPI 1-2007 section 6.3 These truss designs rely on lumber values established by others. RE: Job 68444 A-1 Roof Trusses b 4451 St Lucie'Blvd Fort Pierce, FL 34946 Site Information: e'Gstomer Info: HABITAT ST. LUCIE COUNTY Project Name: 7508 COQUINA "Lot/Block: Model: Address: 7508 COQUINA AVE, LAKEWOOD PARK, FLbdivision: City: County: EXEMPT State: FL Name Address and License # of Structural Engineer of Record, If there is one, for the building. Name: License #: Address: City: General Truss Engineering Criteria Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC2014/TP12007 Design Program: MiTek 20/20 8.0 Wind Code: ASCE 7-10 Wind Speed: 160 MPH Roof Load: 37.0 psf Floor Load: 0.0 psf This package includes 13 individual, dated Truss Design Drawings and 16 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61G15-31.003,section 5 of the Florida Board of Professional Engineers Rules. No. Seal # Truss Name Date No. Seal # Truss Name Date No. Seal # Truss Name Date 1 A0243054 A01 4/25/17 13 A0243066 J7P 4/25/17 25 STDL12 STD. DETAIL 4/25/17 2 A0243055 A02 4/25/17 14 STDL01 STD. DETAIL 4/25/17 26 STDL13 STD. DETAIL 4/25/17 3 A0243056 A03 4/25/17 15 STDL02 STD. DETAIL 4/25/17 27 STDL14 STD. DETAIL 4/25/17 4 A0243057 A04 4/25/17 16 STDL03 STD. DETAIL 4125/17 28 STDL15 STD. DETAIL 4/25/17 5 A0243058 A05G 4/25/17 17 STDL04 STD. DETAIL 4125/17 129 1 STDL16 I STD. DETAIL 4/25/17 6 A0243059 A06 4/25/17 18 STDL05 STD. DETAIL 4/25/17 7 A0243060 A07G 4/25/17 19 STDL06 STD. DETAIL 4/25/17 8 A0243061 CA 4/25/17 20 STDL07 STD. DETAIL 4/25/17 9 A0243062 CJ3 4/25/17 21 STDL08 STD. DETAIL 4/25/17 10 A0243063 CJ5 4/25/17 22 STDL09 STD. DETAIL 4/25117 11 A0243064 HJ7 4/25117 23 STDL10 STD. DETAIL 4/25/17 12 A0243065 J7 4/25/17 24 STDL11 STD. DETAIL 4/25/17 The truss drawing(s) referenced have been prepared by MiTek Industries, Inc. under my direct supervision based on.tne. parameters proviged,DyH-i mor i russes, Ltd. Truss Design Engineer's Name: Anthony Tombo III My license renewal date for the state of Florida is February 28,2019. NOTE.,The seal on these drawings indicate acceptance of professional engineering responsibility solely for the truss components shown. The suitability and use of components for any particular building is the responsibility of the building designer, perANSI(TPI-1 Sec. 2. The Truss Design Drawing(s)(MD[s]) referenced have been prepared based on the construction documents (also referred to at times as 'Structural Engineering Documents) provided by the Building Designer indicating the nature and character of the work. The design criteria therein have been transferred to Anthony Tombo III PE by [Al Roof Trusses or specific location]. These TDDs (also referred to at times as 'Structural Engineering Documents) are specialty structural component designs and may be part of the projects deferred or phased submittals. As a Truss Design Engineer (i.e., Specialty Engineer), the seal here and on the TDD represents an acceptance of professional Anthony T. engineering responsibility for the design of the single Truss depicted on the TDD only. The Building Designer is responsible for and shall coordinate and review the TDDs for compatibility with their written engineering requirements. Please review all TDDs and all related notes., Page 1 of 1 P.E. Z QO;QO,OD 00:4C1Z87 DF` ILE 0u f, Job Truss Truss Type t qy Ply 68444 A01 Common 1 1 A0243054 Job Reference (optional) Al Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.020 s Aug 31 2016 Print: 8.020 s Aug 312016 MiTek Industries, Inc. Tue Apr 25 11:21:22 2017 Page 1 ID:15evE3m?mEmN ESygOUyQA7zPDq?-?RHCZSd6zgLw6chY2tGnc1 gRdv7?P7DYmtl0lgzNCWB 4x6 = Dead Load Dell. = 5/16 in 11 4x4 = 3x4 = 3x6 = 3x4 = 4x4 = LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d TCLL 20.0 Plate Grip DOL 1.25 TC 0.68 Vert(LL) -0.20 10-13 >999 360 TCDL 7.0 Lumber DOL 1.25 BC 0.92 Vert(TL) -0.55 10-13 >571 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.18 Horz(TL) 0.09 6 n/a n/a .BCDL 10.0 Code FBC2014/TP12007 Matrix -MS Wind(LL) 0.19 8-10 >999 240 LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 3-9-0 oc pudins. - BOTCHORD Rigid ceiling directly applied or 2-2-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation uide. REACTIONS. (lb/size) 2 = 1028/0-8-0 (min.0-1-8) 6 = 1028/0-8-0 (min. 0-1-8) Max Horz 2 = 86(LC 16) Max Uplift 2 = -428(LC 8) 6 = -428(LC 9) Max Grav 2 = 1028(LC 1) 6 = 1028(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=2129/1846,3-4=-1767/1494, 4-5=-1767/1494,5-6=-2129/1846 BOT CHORD 2-1 0=-1 620/1973, 9-10=-948/1375, 8-9=-948/1375, 6-8=-1622/1973 WEBS 4-8=-317/471, 5-8=-443/607, 4-10=-317/471, 3-10=-443/607 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf-, BCDL=S.Opsf; h=15ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 428 lb uplift at joint 2 and 428 lb uplift at joint 6. LOAD CASE(S) Standard 26-4-0 PLATES GRIP MT20 244/190 Weight: 111 lb FT = 0% au b!-nyua. �!tlre er ne'ia tars Hess s fs uu ; [rau r2us smoiner, tosrau lcm trsn,�[usu:rrn n lrelte mla, s uRtrKt wn nrt, rr,,, e,vl,o a.�llm;m n,e o atlt. r,.l, m,et. a en, s�am.e n m,u ftu ",nelw ae naair wratrm@rpW ,WkuetLrSe;CCuke,�t. As�irns05g6lesx(w.`l�rR[�l��.fi=:%+a�t�+rgre:anmrsalcaedrolnk:slmly;evriy,�grzaitnNeeks�dCew�eTmslgztbnritaBrrfl,n[nl!ll.l3eksry,.sa¢l:ru,fieeelu,+�y,ccniesGm pnthonyT. Tom III, P.E. ,.en:nn,rru,W.1 bag isa,rrgn&fiJ+ro—,e+0—".4a¢ri94.,144in®lam.7.'b1'.Wfl5rrc&eR[d5rb'dWfiq,diMTR�Likzery:,nldGrl:CMgfidirud8r[ms,icdKhgkdi�,sl:qe,ue,Creanike,slsll!leCen<lnsiiilald v80083 ' mdar�lg:aava[t.r �,.m.ms,ambmroon+sepru5nsmlii:r snmlaslu tAU1Daj.,,ar7i,ptsglackute.1K ft,garnsila0hrupind611:iw,eserresl�si+innlaauan:rnsso grinsso-em:grmnitns:eu.t�m.i.du,. 4451 5t. Lucie Blvd. .emrwiexallrrt,mengmagna.�lryzll,�m,m,nrl. rkrrrso,cur,�,rsrxMur+�ga,�l.,,urorslmslgex,rMnar�y m,leanrflKecu,nad�ainms. Fort Pierce, FL 34946 Copyright�y016AdRoo(Lassos-AnlhooyLlamhalll,P.F. Repradu,siaeaphisdeiraber,inany form, isplohihilelwahout[be afienpemissionlmmA-IRadhusses-AnhonyMmahalll,p.F. 4r I Job Truss Truss Type Qty Ply A0243055 68444 A02 Hip 2 1 Job Reference (optional) Al Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.920 s Aug 31 2016 Print: 8.020 s Aug 31 2016 MiTek Industries, Inc. Tue Apr 25 11:21:22 2017 46 = Dead Load DeB. = 5/16 in 3x4 = 3x6 = 4x4 = 4x4 = 3x4 = LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d TCLL 20.0 Plate Grip DOL 1.25 TC 0.68 Vert(LL) -0.20 8-16 >999 360 TCDL 7.0 Lumber DOL 1.25 BC 0.92 Vert(TL) -0.55 8-16 >572 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.18 Horz(TL) 0.09 6 n/a n/a BCDL 10.0 Code FBC2014lrP12007 Matrix -MS Wind(LL) 0.19 8-10 >999 240 LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 3-9-0 oc purlins. BOTCHORD Rigid ceiling directly applied or 2-2-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation quide. REACTIONS. (lb/size) 2 = 102810-8-0 (min. 0-1-8) 6 = 1028/0-8-0 (min. 0-1-8) Max Horz 2 = 85(LC 12) Max Uplift 2 = -428(LC 8) 6 = -428(LC 9) Max Grav 2 = 1028(LC 1) 6 = 1028(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2129/1846, 3-4=177211497, 4-5=-1772/1497. 5-6=-2129/1846 BOT CHORD 2-10=-1619/1973, 9-10=-956/1384, 8-9=-956/1384, 6-8=-1621/1973 WEBS 4-10=-313/468, 3-10=-436/599, 4-8=-313/468, 5-8=-436/599 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; Cat. Il; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Plates checked for a plus or minus 0 degree rotation about its center. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 428 lb uplift at joint 2 and 428 lb uplift at joint 6. LOAD CASE(S) Standard PLATES GRIP MT20 244/190 Weight: 111 lb FT = 0% wLIig-flmtnimtytirrtnea 6e'1 nCu'IaSSc�',irdFl �e[[7111.14560gD11YlS(DSiDY'rbT,Y;!(16:8[IDa"fl:Mrha. rrdr Riipwishnnt�nl pain M, W, M4 ..IgrrC;ml M"r.ralrle, IS.I&— S'rn!ft— t<kaidat ttHerb 6e RD,Wt '. MAX—," ann!1DDdir.nenlnLratAnthony T.Tomho1I1,P.E. ntn!dla,imstnwlt iwss i,C!n:pnulrydde0•rgen C.re%re>tkrmd neLn S!saHaD Dn.�a,h3runeArfti+nCRrt3(nitie lril ixtfiq,dsasitll Da ennnlAf rrJDa/asfielsnrd8rhr,s; cdetiyMA ,!Ix!se,usf,7.eraalfmos vuleWn4rni>eiryA =80083 ' lie hrafvpD:si�a coifs»son. IDrrtes,tlrne14100 n1srcsans nsrziernndfctodi+s ucprxtsh¢W!izrroelrSGrd5�s!stl EPns iCAse:de!n!ebrpa7a{idese. tMtfdonrtc nssnxM:naiA+ia Ala:lmss D:upn,im!De!G,6ir!nnllnnkuAr3nei,nlns 4451 St. Lucie Blvd. rN:•mufaslrsswem eQedgnanGss is sl p!mnlmh:r. rn rns+Decn blawisfldrkellirp OesipwgnLnt stars 6pG+wd. n7trlsa}NnsodmdNasmnd¢findailsl" Fort Pierce, FL 34946 Ceppight dj ti1166.19aa1lmssts-hthocy E. Eomholll, P.L Rtptodarlan alibis dotoment,in any form, is ptohibiied witboottbe"itlee permission. from A -I AaalLasses-Aat6aayLlamhe lll, P.E. IN t Job Truss Truss Type Qty ply 68444 A03 Hip 2 1 A0243056 �J.bR.ference(optional) 7-10-13 V�V VID:15evE3m?mEmNESva01 44 = 4x4 = 4 S n n WUDU roa, IrrG. r uu Hpu zo 1 i;1 i;zJ Luz r rage i Y7zPDq?-Tdrbnoe kk8Tn kmFkca n09 EMb3JZf8awh?XUZI GzNCWA Dead Load Dell. = 3/8 in A 4x4 = 3x4 = 46 = 3x4 = 4x4 = LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.76 Vert(LL) -0.23 9-17 >999 360 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.57 Vert(TL) -0.62 9-17 >511 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.15 Horz(TL) 0.07 7 n/a n/a BCDL 10.0 Code FBC2014/TP12007 Matrix -MS Wind(LL) 0.19 11-14 >999 240 Weight: 106 lb FT = 0% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 3-5-3 oc puriins. BOT CHORD Rigid ceiling directly applied or 6-0-2 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation uide. REACTIONS. (lb/size) 2 = 1028/0-8-0 (min.0-1-8) 7 = 1028/0-8-0 (min.0-1-8) Max Horz 2 = -73(LC 13) Max Uplift 2 = -445(LC 8) 7 = -445(LC 9) Max Grav 2 = 1028(LC 1) 7 = 1028(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2012/1684, 3-4=-1693/1410, 4-5=-1581/1368, 5-6=-1693/1410. 6-7=2012/1684 BOTCHORD 2-11=-1449/1851, 10-11=-1057/1581, 9-10=-1057/1581,7-9=-1450/1851 WEBS 3-11=-395/509, 4-11=-246/361, 5-9=246/361, 6-9=-395/508 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) Plates checked for a plus or minus 0 degree rotaltion about its center. 5) This truss has been designed for a 10.0 psf bottom, chord live load nonconcurrent with any other live loads. 6) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 445 lb uplift at joint 2 and 445 lb uplift at joint 7. LOAD CASE(S) Standard W-1•Flmv @unlellrzue+6e'LI1@;f 116SSUITnin mEtni Etvs&ms,,nm 7sTC@Si41:r)LIC[;3tf@54fY1'lun lndl&rip ya�Nn nl rnenksntds fnnhfip Orre's1�IW�W a, worl.rtl oo•InmJn@e S5@,- IListmaxanlWatsk@kruldr@I;ri;ule ldd. Isalrus@es. s 1 -a." N.a4neffrair;non7tr'lt@�r�msm'6,,Q.do.lrxa::nanon:r0111.:@rirf 1do,pate�mpr�sly�nr�loonll...erzrntr�impn mpn<.461,Le+aa umm:al Anthony. narse.l@:;Tnat�®rl.umsarzrrrynuau;lad@..rr,m@,Nseanurlgrnw:r�lo��e.e,t,nnradn,n;,@rlttelri.nrf�,mi�ntml. rteell,n.lau.m@ne�@:u.nr.@et n,aatr�lenn�f;,mrp.au„n„attn�s�lr@an<pm;�alp Y Tombo (II, P.E. ' 6,Wr o•a adt.rsar. nwts'd.airet@Yndlx mCuesnd telnna@e = - = 60083 q • w 1 r� Raf Mk.111Skigt '.11miSI ftE�eht9VIA14 agimmngmsapierxi'da'. a@.rzgm tfmnfh@na2lnn@:sps,Tnssm:grfapenntfms@.aaamm�,�aas 4451 St. Lucie Blvd. .@mmshGa111nfxomeye.•dgnRnrslYrmlxaesinasN.tlatnn@eCp(,laNrnL7rrbGuivg@.sipnpusuSrmsGln�caerye�u�.Nnldealrzasmnt�nfrcmL Fort Pierce, FL 34946 (epydgh197016blRodTwsses•AathooyLlomhoili,P.E. Reptaloolonafthisdoromeet,inany form, isprohibited w*whemirtinpermission from A•IRoof frusses•Anthonyf.lamhofli,P.I. :J R Job Truss Truss Type Qty Ply 68444 A04 Hip 1 1 A0243057 Job Reference (optional) Al Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.920 s Aug 312016 Print: 8.020 s Aug 31 2016 MiTek Industries, Inc. Tue Apr 25 11:21:23 2017 Page 1 ID:15evE3m?m EmN ESyg O UyQA7zP Dq?-Tdrbnoe kk8Tnkm Fkcan09 EMX_JVK8bJ h?XUZ IGzNC WA 1-0-0 9-0-0 17-4-0 26-4-0 27 4-q 1-0-0 9-0-0 B 4-0 9-0-0 1-0-0 4x6 = 4.00 F12 4x6 = Dead Load Defl. = 1/4 in 4x4 = 1.5x4 11 3x6 = 1.5x4 11 4x4 = 9-M 17-4-0 26-4-0 9-M 8-4-0 9-0-0 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.96 Vert(LL) -0.39 7-15 >802 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.79 Vert(TL) -0.59 7-15 >539 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.13 Horz(TL) 0.09 5 n/a n/a BCDL 10.0 Code FBC2014/TP12007 Matrix -MS Wind(LL) 0.26 9-12 >999 240 Weight: 91 lb FT = O% LUMBER - TOP CHORD 2x4 SP No.2 `Except* T2: 2x4 SP M 30 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 5-1-10 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation uide- REACTIONS. (lb/size) 2 = 1028/0-8-0 (min. 0-1-8) 5 = 1028/0-8-0 (min. 0-1-8) Max Horz 2 = 61(LC 12) Max Uplift 2 = -459(LC 8) 5 = -459(LC 9) Max Grav 2 = 1028(LC 1) 5 = 1028(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1976/1456,3-4=-1812/1466, 4-5=-1976/1456 BOT CHORD 2-9=-1211/1804, 8-9=-1208/1812, 7-8=-1208/1812, 5-7=-1211/1804 WEBS 3-9=0/331, 4-7=0/331 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces 8: MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) Plates checked for a plus or minus 0 degree rotation about its center. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 459 lb uplift at joint 2 and 459 lb uplift at joint 5. LOAD CASE(S) Standard wn6R•nxlnwreSklJMr.Yre'id iggf tiL5S3('s'.illi').5fr3r1I,7YstG7tMICR(71Tau-rerX?urecnulwu;lr� inJr6rip pR:prnMrul u'ernftis frnree9JlUnrur(N:'JwltN knaJLrulem,Pf.lfurn sic!td¢e nl. iekue]erbe afNn¢e1Cfl,erlr IsrT.kr rpwssSmkeselUr!< n4rdt nlJrnsO:s Fq w(u,5iemlh rgi> 0lsolosoJiM+grouuwrcgawlddrfr�.:sindumnrigrapn:rtft¢N;ftlnndhsuy'rTm:IgNNutkJggedJ,ut¢IIFL ruemp nunrens,IMhrmlout:rdsfE%. Anthony T. Tombo 1I1, P.E. neluAhsimstm mJ6i�:sJ is ae inpn-vLryA6sOnq S+Cm'slAwuei esednhe ta7fmlgage,oRe nAerizlGlO4Re lIX¢/raLad�:7Gryoh nlJnl. rlx gpnddfirfl0.et vJfiMrud6r loss,(rdlC�gluilny+lage,vslr"eun¢Iknns sid;k4rnslnsn9dfd. �80083 Ztd laentt!.0r.IDCrdrt'1 cn nlpx:f rr el nelriSq G:}arlSishlsfiizdrn{16U1e16.1N IJIflNSiG errdeerei ixpasd pgsu. Inl defimftrngnu38Ns alhersdlL•1nnUeipn,Tnss Critr fq nn uilnuVmfiarreynlsn- 4451 St. Lucie Blvd. In¢wnldehedlJltNaRlgrldlplalnn:glJrlp;mlilydlellM6nDn:nGai¢silsE7rftrkimgOngx+,nLnsssntzErsimr.ofnrh:ldlq.la¢Jatlndlwasmrslr8rdsnn' Fort Pierce, FL 34946 (oppighe020166-iRaal6ossas-WasyLTomb III, P.E. Repioduuianaphisdomment;inany form, isprohiEitedwithouffhow1hrenparminiaafrom 6dRoalbosses-AnshonyLTanboIII, P.L Truss Truss Type qty ply ;684�44 A05G Hip Girder 1 1 A0243058 Al P—f 7r.— a r:,,.e oto.,.- =t gdonc .,,...:.......,..,......_ ___ ___ Job Reference (optional) 3x8 = a .- .•.--�•w•• ,...�,. �.aw a ..ug a u iu ruu!. o.ucu s ID:15evE3m?mEmNESvc 3x4 = 5x10 MT20HS= J-E Gu i u mi I eK Inousmes, inc. I ue Apr 25 11:21:24 2017 3x4 = Dead Load Dell. = 112 in 3x8 = LOADING(psf) SPACING- 2-0-0 CS'. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.76 Vert(LL) -0.37 9 >853 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.79 Vert(TL) -0.87 9-10 >363 240 MT20HS 187/143 BCLL 0.0 Rep Stress Incr NO WB 0.44 Horz(TL) 0.21 6 n/a n/a BCDL 10.0 Code FBC2014frP12007 Matrix -MS Wind(LL) 0.52 9 >610 240 Weight: 110 lb FT = 0% LUMBER - TOP CHORD 2x4 SP M 30 *Except' T2:2x4SIDM31 BOT CHORD 2x4 SP M 31 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 2-8-3 oc purlins. BOT CHORD Rigid ceiling directly applied or 4 4 4 oc bracing. WEBS 1 Row at midpt 4-10, 4-8 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 2050/0-8-0 (min.0-1-11) 6 = 2050/0-8-0 (min.0-1-11) Max Horz 2 = 49(LC 8) Max Uplift 2 = -1098(LC 4) 6 = -1099(LC 5) Max Grav 2 = 2050(LC 1) 6 = 2050(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-5266/2760, 3-17=-5003/2682, 17-18=-5003/2682, 4-18=-5003/2682, 4-19=-5003/2683, 19-20=-5003/2683, 5-20=-5003/2683, 5-6=-5266/2761 BOT CHORD 2-10=-2560/4934, 10-21=-3181/6459, 21-22=-3181/6459, 9-22=-3181/6459, 9-23=-3181 /6459, 23-24=-3181 /6459, 8-24=-3181 /6459, 6-8=-2518/4934 WEBS 3-10=-463/1138, 4-10=1645/683, 4-9=0/531, 4-8=-1 645/682, 5-8=-462/1138 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=S.Opsf; h=15ft; Cat. II; Exp C; Encl., GCpi=0.18;'MWFRS (envelope); cantilever left and right exposed ; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) Plates checked for a plus or minus 0 degree rotation about its center. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1098 lb uplift at joint 2 and 1099 lb uplift at joint 6. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 201 lb down and 241 lb up at 7-0-0, 121 lb down and 139 lb up at 9-0-12, 121 lb down and 139 lb up at 11-0-12 , 121 lb down and 139 lb up at 13-2-0, 121 lb down and 139 lb up at 15-3-4, and 121 lb down and 139 lb up at 17-3-4, and 201 lb down and 241 lb up at 19-4-0 on top chord, and 398 lb down and 352 lb up at 7-0-0, 85 lb down at 9-0-12, 85 lb down at 11-0-12, 85 lb down at 13-2-0, 85 lb down at 15-3-4, and 85 lb down at 17-3-4, and 398 lb down and 352 lb up at 19-3-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25 , Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 3-5=-54, 5-7=-54, 11-14=-20 Standard Concentrated Loads (lb) Vert: 3=-153(B) 5=153(B) 10=398(13) 9=67(B) 8=-398(B) 4=-121(B) 17=-121(B) 18=-121(B) 19=-121(B) 20=-121(B) 21=-67(B) 22=-67(B) 23=-67(B)24=-67(B) e!,�E-renea fEEI!Emr;EnrEsruuONrErauEEmrrrmomersEosro@ rcrryiEerasmsutrmaEama,y.�,wnnne vm!na,tRnr,:r!ca�pevW@el@erE.lutem,rirhnnik!tdeew.Cdruft.mcddnee.M.It IBLksmxV*.I sSAkosdUr@ePR'p4str. lsolmsenee Eqn!sL,fyrntifiry,r:@!sednagiGurgnsuss®ovreaedhep0aniril egn�!igrnpn4i�lo,trl!!god@esny!im;tq�.dtth:E�Dedl.W.M. Nit pnvy6ks, t�fnim4iue,sNilt'At Anthony � [II, P.E. ndned R!Lnsa.gE.��tE!mraru!c�.jdtra„a,ac.!d!en.ddq!xn@!&Jfal Um.;ee,h3e udeddhe�@!IG nI@rinei�!Ifm3olzMRtl. hx!p:nddfie tODae ®tkll.ud@!L s!: hdstigkuiw, ss..1"a fdxtiu»d al Fny,t. 1 ".ward T. 8008 @!p;IfgOlA�eralu�+ea!r.t@ede!s9Nue:iDOnllaruauesed rrid.!eltleleufai G�{erslSt!ryldusdeullSQldE.kl it E!;od SSGmuk!r.!fN. rvsdpilexe. Mlefim@e ngnsSlnet nEktiadk!in!e0!r,ea,Uns k!n Ey!eeeeilnss ru.67m!;nhst !steirh!&Fadlro(uamsgndgnh x!csg tyd puns inoh!A IM Err! Rs�n hE1m,s I! E.reetrJligOripyrLns$dm Gsn!a ofuy h:liby. Naradad tees m os rdlsdk7F1. 4451 St. Lucie Blvd. (oPyrfRhs sD 2R1b A-1 Raaf Trusses-AaEhoayL Iomba III, P.E. Repradudian olthis doromaat, in ony form, is probilited withantthe wrinenpemissiao from 114 Roof Cusses-Ardany L Jumbo III, P.E. Fort Pierce, FL 34946 Job Truss Truss Type Qty Ply A0243059 68444 A06 Hip I Job Reference (optional) Al Roof Trusses, Fort Pierce, FL 34946, design@altruss.com 4.00 Run: 8.920 s Aug 31 2016 Print: 8.020 s Aug 31 2016 MiTek industries, Inc. 1 ue Apr 25 11:21:25 2017 1 IDA 5evE3m?mEmNESygOUyQA7zPDq?-POyLCUfGljVz3P7j?gUEfSuv6FTcHQ_SrzgM9z 17-4-n - • 1 26-4-0 274-0 4x6 = 5xB = Dead Load Dell. = 3/16 in '. 1.5x4 it 4x4 4x4 = 3x4 = 9 8 7 3x6 = 10-8-0 26-4-0 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.93 Vert(LL) -0.11 10-13 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.55 Vert(TL) -0.33 10-13 >397 240 BCLL 0.0 Rep Stress Incr YES WB 0.92 Horz(TL) 0.01 14 n/a n/a BCDL 10.0 Code FBC2014lrP12007 Matrix -MS Wind(LL) 0.1310-13 >999 240 Weight: 104lb FT=0% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied. BOTCHORD Rigid ceiling directly applied or 6-0-0 oc bracing, Except: 8-0-6 oc bracing: 2-10. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation ouide. REACTIONS. All bearings 15-8-0 except at --length) 2=0-8-0, 9=0-3-8. (lb) - Max Horz 2= -61(LC 13) Max Uplift All uplift 100 lb or less at joint(s) 9 except 2=335(1-C 8), 7=-340(LC 9), 5=-232(LC 9) Max Grav All reactions 250 lb or less at joint(s) 9 except 2=659(LC 1), 7=928(LC 1), 5=397(LC 24), 5=388(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOP CHORD 2-3=-817/698, 3-4=-6971737 BOT CHORD 2-10=-486/706 WEBS 3-10=-215/316, 4-10=-659/873, 4-7=-761 /751 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces 8: MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water pending. 4) Plates checked for a plus or minus 0 degree rotation about its center. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 9 except (jt=1b) 2=335, 7=340, 5=232, 5=232. LOAD CASE(S) Standard W=-"mm WA im. lit'AatxllMrsEur;enrlTRwrmOrars to-ssaeru!u'fxs f,;:¢wa1'n�, tandtc�t-rrns�t(rcerr.,nr innc:�ncr.�aiao- ranc:,na:.s.?(�soarf.um(a,sltatt4�e.sc r�r:a'..� tcet��emu,tcq ui°dctex�r:ts.t hn:dtaAtlC2tehnFl.;:t6:ns:r„�5eaenytyt•FKSGt'xm(tAa:rs.ttmrlWnpnessna.:(t'c�zReac!risa3d.++,eedgrrpn:+�rkbei.utdsesiz�al(a»i!7br(matC6eth,,astrRtl.'.'nd:rysns rs;lnra�rr<e,sztrli, 3tnYoonyT.TomboIii.RE. :dmdtltsGrl hrtnAid.. uarrr.FrEsi[e!r€d!Gst;�C'sst(ca6erudt;MahsAs3s;'� ,use! nod&t.It,te 4:rsiceMal is :t!�stl}tl. lrgpt(ddGtl teiu;§elt.0 d;t ifm..tim}k u},4an;;aH+xaedkrtatfkEl Cx(snagii:a;� 380083 atrzwsw;a�tt�mnr.:Z�rrntaaetro-etFar ,� �(rdecr��a rs tnauita�tctaq=.rltes�o((day!amrr�ete,tru csst(e!ra: tan�,cr�tm(rtr,,t ttia�r.� earrau�,m,(etx 4451St. LucieBlvd. dvwufifi:01.(aa' V'dga 4"1!talm'swrtheili IIt LmsOlfl;1F[jzf�l:ial[k(i.It�1;:IfI;iYep r�35 SrSF!WF[SittHdN1FGSCj, A®LLr�V ltth!L^bl6ii dalPN. Fort Pierce, FL 34940 LopyrilkiQ2d16A-Iloollmses-Am6oeyl.lom6oIII, F.E raptodattienofttisdotnmeot.inany farm, isprabibited.isbeatThe nritltnpermissionhomVPool lrasses-Am6enyl.lombaIII, r.E Job Truss Truss Type City ply 68444 A07G Hip Girder 1 1 A0243060 Al Roof Trusses, Fort Pierce, FL 34946. desian(o�altruss.rnm a. i„• a oon � e,a, nn,c o.:_.. a �.,.. _ ..._ Job Referenceo tional.. ,.......,...._ . . 3x4 = • ..y .. , �.. w rvn , en muuau ros, nre. , ue Apr " l I:zl:zb zUI / I D:15evE3m?mEmNESygOUy0A7zPDq?-tCWjPggcl3rMbD_JHjl-jnt_4lWXPLjIBhVJDvt Dead Load Defl. = 3/8 in bxlz = 4x6 = 3x6 II 3x4 = LOADING (psf) TCLL 20.0 SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCDL 7.0 Plate Grip DOL 1.25 Lumber DOL 1.25 TC 0.86 BC Vert(LL) 0.52 8-10 >353 240 MT20 2441190 BCLL 0.0 Rep Stress Incr NO 0.83 WB 0.98 Vert(TL) Horz(TL) -0.55 0.05 8-10 6 >336 n/a 240 n/a BCDL 10.0 Code FBC2014frP12007 Matrix -MS Weight: 113 Ib FT = O% LUMBER - TOP CHORD 2x4 SP No.2 `Except` T2: 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 *Except* W3: 2x8 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 3-9-10 oc puriins. BOT CHORD Rigid ceiling directly applied or 4-9-1 oc bracing. WEBS 1 Row at midpt 5-10 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 524/0-8-0 (min. 0-1-8) 10 = 2544/0-M (min.0-3-0) 6 = 941/0-3-0 (min.0-1-8) Max Horz 2 = -49(LC 32) Max Uplift 2 = -268(LC 4) 10 = -1977(LC 4) 6 = -896(LC 5) Max Grav 2 = 525(LC 19) 10 = 2544(LC 1) 6 = 944(LC 20) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-583/243, 3-18=-344/529, 4-18=-344/529,4-19=-344/529, 19-20=-344/529,20-21=-344/529, 5-21=-344/529, 5-6=-2055/1951 BOTCHORD 2-11 =-1 88/497, 11-22=-199/525, 10-22=-199/525, 9-1 0=-1 801 /1945, 9-23=-1801/1945, 23-24=-1801/1945, 8-24=-1801/1945, 6-8=-1754/1899 WEBS 3-11=-168/478, 3-1 0=-1 223/713, WEBS 3-11=-168/478,3-10=-1223/713, 4-10=-833/664,5-10=-2565/2351, 5-8=-757/845 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=S.Opsf; h=15ft; Cat, ll; Exp C; Encl., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed ; end vertical left exposed; porch right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) Plates checked for a plus or minus 0 degree rotation about its center. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 2=268, 10=1977, 6=896. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 201 ib down and 241 lb up at 7-0-0, 121 lb down and 139 b up at 9-0-12, 121 lb down and 139 lb up at 11-0-12 85 lb down and 127 lb up at 13-3-4, 85 lb down and 127 lb up at 15-3-4, and 85 lb down and 127 lb up at 17-3-4, and 165 lb down and 229 lb up at 19-4-0 on top chord, and 398 lb down and 352 lb up at 7-0-0, 85 lb down at 9-0-12, 104 lb down and 146 lb up at 13-3-4, 104 lb down and 146 lb up at 15-3-4, and 104 lb down and 146 lb up at 17-3-4, and 428 lb down and 511 lb up at 19-3-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25 , Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 3-5=-54, 5-7=-54, 12-15=20 Concentrated Loads (lb) Vert: 3=-153(F) 5=-117(F) 9=-98(F) 11=398(F) 4=-1 21 (F) 8=-428(F) 1 8=-1 21 (F) 19=-85(F) 20=-85(F) 21=-85(F) 22=-67(F) 23=-98(F) 24=-98(F) IrmnT-Hew nmy!¢rz..rtu'1d r0:F Pit 110Py D.Ipt l7@1841kPlluall7fi0Yy'{Crr)H[5neveeWrrme h:irywyrµc9«,ut«ds'iramern«ea+�na.uTpk:;a9fle 1:1lar 1. rrttla l7,rf.reM �nmma, es,, e,4«afte.�x rnetnsr 2m.«�r tLTFe f9IDeQ1 �!«ts�ktfelW; Se TCCNIe Ii:L IIITIafaa�6rtga{�.sr:,,.arrgla!fg ne 3alpffiTrai ltnarzif ma«glartdMTaltaiafl«�mulrapaJuriwSt lrsyad�esirT'eTte<:Iq�n6e16aeJr,ecla lTs4 rale:gex„arG«t, IxtrtiuNeetc,faTilGm ' wnedksiuu9:wtlriff*SI,ReiniraalatdPwano,aa0.xt,eAsradgr;«deb7FclCa.'a,o3eariedrt6ell4ftelS(alfahllxYq,dralRl.tkeepmddfieNAetorfieNaetlfiri:s:lodetnTkt«lin,,IxeJe,esb`ena«iLmsesidle�«gmieliryel Anthonys.Tornbo111,P.E. mrxyeeura,error.ss«r«:dmheTodrdxtT«nmalp�.ier«rsdmwa.�e;��«eisc.pL�:am;nsl�Te::<ltrrrwsttt.rrrrarrtlx�,�s.sl,ee.tnt��nnermra«vwandas«dt�trs,;us�s,T«s:�:ryeryseawTa,sna«n,wm 80083 Mavtaid9NH t (rzhmepatgn h v,@[a 7mirnk, Yr,heA In lm he« Ora« «E7rftr iatligaeUTaeerLass<rnea 6lma ofaT krlfv7. tll«tdmr!'aa: m rs ad«,l6: W. 445i St. Lucie Blvd. ru ht92016 Ad loolhusses• Anthony T. Pampa ill, P.F. Repmdwtim aphis doromsat,in ao form, is rohihited whhoutibe mfntnptimissiuo hom Ad Raol6usses- Aothonyl. Yamho III, P.E. Fort Pierce, FL 34946 PY�9 Y P Job Truss Truss Type Qty Ply A0243061 68444 CA Comer Jack g 1 Job Reference (optional) Al Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.920 s Aug 31 2016 Print: 8.020 s Aug 31 2016 MlTek Industries, Inc. Tue Apr 25 11:21:26 2017 Page 1 I D:15evE3m? mEmNESygO UyQA7zP Dq?-tCWj Pggc13 rM b D_J Hj Ljnt_Gj WJALy 18h Vj DvbzN CW 7 -1-0-0 0-11-11 1-M 0-11-11 LOADING (psf) SPACING- 2-M CS1. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.10 Vert(LL) -0.00 5 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.01 Vert(TL) -0.00 5 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 2 n/a n/a BCDL 10.0 Code FBC2014rrP12007 Matrix -MP Wind(LL) -0.00 5 >999 240 Weight: 5 lb FT = 0% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- LOAD CASE(S) TOP CHORD Standard Structural wood sheathing directly applied or 0-11-11 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation quide. REACTIONS. (Ib/size) 3 = 8/Mechanical 2 = 11810-3-0 (min. 0-1-8) Max Horz 2 = 40(LC 8) Max Uplift 2 = -113(LC 8) Max Grav 3 = 19(LC 3) 2 = 118(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=113. tm', j•nns+e .'P a -N%I aanre ssrs ta; �esu i eM1s a e�xoin n rniou rserlue4;rt[�urer mn a rtren>. j, = mene:nl wn n mt rnnrn;j.wc bjPe war ary i. r�k m,et rr n, sk:t aeni t4 ar>an.ee cA ee Re l�.nh PTAmmra:rines odlknedtxM1e iCGbhedd.ls eimsO Eeib±n[u,'.itaelryterye,�M1efMnasj ih;rt}rtscds m.nybardtit jtehsu.»I ee migtnjanitttj6;Qt/tojeel2e Sbj4 rtns rej'1'd s1�IC0ulj,nin RFI. TxGvjf eivmines,le!@jtu45114`.e�1'-dj Anthony T. Tomb, ltt, P.E. and nedh;T:nslxaq klNxjlsde ncpetlSLrydd Orin, eeCneeo>alsmri yrdu M1e Wrq On:µe h5tumd dtitlPbrlxml rrlertlbtfiyteh n/RFi. ik enmddfirfirMrykdnrdtlrims;bbiiyknibj, dneie,bsle'enn ue lrnrr Jdlle QrnfjnsirJfid 480083 Mk:IfarCesiperstOmedtr.11lMnftlrd'uM1e7UCnlSerrtCiasul(7:e�f fdtklvr7Ey0cytaelSlehl6:zetim;rlSfljd6;laelrlFlnlS3GmrdntHlxiwdpM1rae.itjli�uslkngn trnlAM1ttdmelm;0:f?,�n,ins,k:gehy><nnnnm,dmnonn,nbss. 4451 St. Lucie Blvd. enrtmirr�zilrerxnm.�eaynunex,ryc7p:nrsbnh:tikinn[xonej�ntlsrmkku�goenpu,nitntsrens:ujbend.yh:uop.mtyednernta;ueua�tdumt Fort Pierce, FL 34946 topjright-D20166dRoofLumas-lkshooyI.tomb,ill,P.E. RCIndUdINOf1hisdommo-nt,innnyform,isprobihhad whhoutiM1esninenpermissienhom6dAaofLossn-aethonrf.iemboIII, P.L Job Truss Truss Type Qty Ply 68444 CJ3 Comer Jack g A0243062 Al R—F T--- 17—t Pi— F! 'iAQAR .1—;....u,.,,........ _,.... --- Job Reference o tional Kull. ur m ID•15evE3m?mEmNESygOUyQA7zPDq?-MO45dAhEoNzDDNZWrQsyJ4XQbwl44PHHw9SnR2zNCW6 -1-0-0 2-11-11 1-0-0 2-11-11 2-11-11 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.15 Vert(LL) 0.01 4-7 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.16 Vert(TL) -0.01 4-7 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 3 n/a n/a BCDL 10.0 Code FBC2014/TP12007 Matrix -MP Weight: 11 lb FT = 0% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 2-11-11 oc purlins. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation quide. REACTIONS. (lb/size) 3 = 63/Mechanical 2 = 171/0-3-0 (min. 0-1-8) 4 = 36/Mechanical Max Horz 2 = 72(LC 8) Max Uplift 3 = -54(LC 8) 2 = -163(LC 8) 4 = -36(LC 8) Max Grav 3 = 63(LC 1) 2 = 171(LC 1) 4 = 49(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf,, BCDL=5.Opsf; h=15ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3,4 except Qt=lb) 2=163. LOAD CASE(S) Standard Wertur�Flen mroyk¢re.serau'f�l EOl;lTMSO�tlE1)elr�ilTiL'gdtaemafds(�SrOY-t4Ttr)i(LG:atlRifgi('hc rergl teilnlrtrtMatredWntteissmslt!Ip Omurp�WgtlegorLttxlrly;rEltMtt,T lke!tdee roc. Cequ Cmise tnitlnGe R4nl( . WT!t=01Or' sokn'Wll TkBklt tit dsrTrnsbesrF hj=eQ.4ip,drhlsst?, ft rd nas Mnsrut.1, egbndgs{rfiessgatluSnntolrz:pmsitthfn xt/tnratlge W¢r1-i,;d!d.WTN"lf'W.tat.Nit;ql esvo(<tn ltr/nEud4ier4sahN!e[ Anthony T.T0r11b0III,P.E. gull'erCssi�erolh#Jn,111.1sdriut4ID.1h PEimnlp'r-dtklnlly hcpeeelStthlhrzrtim(115�1si64sl It IN.1 SKlnrrlaedixf."pilaf. 1111 id-timsimbIri.Wdtod RlsnsOd'^Tnss rr..,nhrstnollrtssVmfiA.rn,Mns =80083 ramly lefsdltn Enaaagredgn W v!Cq 7dlrraa Indrti In Iro;sDrknh)mtr Is Etigrklliybtifatr,oLtnlydes h1Wen mn,•! tiul. NalMgs! L+a; rat rsdr5eel hTlFl. 4451 it. Lucie Blvd. (a h1�7pldAdrool6assos-klhonClomboill,P.F.Itpodudiaaalibisdocument,inan form, is rohihited011001lEeWrittenpermissionfrom A-IpoafTiusses-AaabooyT.Tonbolfl,P.I. Fort Pierce, FL 34046 Pln9 Y r Y P 4" Job Truss Truss Type QtY Ply A0243063 68444 CJ5 Corner Jack g Job Reference o tional Al Roof Trusses, Fort Pierce, FL 34946, design@altruss.com Run: 8.920 s Aug 312016 Print: 8.020 is Aug 31 2016 MiTek Industries, Inc. Tue Apr 25 11:21:28 2017 Page 1 ID:15evE3m?mEmN ESygOUyQA7zPDq?-gbeUq WhsZg54gX8iP7NBsl4V DKG UpsWQBpCKzUzNCW5 1-0-0 4-11-11 1-0-0 4-11-11 M 0 "r 3x4 = LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.54 Vert(LL) 0.12 4-7 >476 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.53 Vert(TL) -0.07 4-7 >844 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 3 n/a n/a BCDL 10.0 Code FBC2014frP12007 Matrix -MP Weight: 17 lb FT = 0% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 4-11-11 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation quide. REACTIONS. (lb/size) 3 = 114/Mechanical 2 = 241/0-8-0 (min. 0-1-8) 4 = 62/Mechanical Max Horz 2 = 105(LC 8) Max Uplift 3 = -100(LC 8) 2 = -217(LC 8) 4 = -66(LC 8) Max Grav 3 = 114(LC 1) 2 = 241(LC 1) 4 = 86(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 4 except (jt=lb) 2=217. LOAD CASE(S) Standard anbt-aesrnn�rmn ae �F Faz*lessis;5r:1Ft;�tau F!tasscuamans maou{uns'yuseoa:FeFwsrt�a F�nit:iy.prow,rw,ns re,n"s,F,<„a:�po�.��)nlmwytrub m,rt.Fr�:n,tsn,ea., w.cFrn asx=ive rndMme Feo.ny wi.kca p,ltlr. �krseetx.x PCbk,dilselmsOs�htrseru,!Femt7(Ena tle:sFnaFb rgmmse,rgrye4n:lMry s n:b :yr-pw t t�uengn�m{ F :t au toonir,n nml Fkaspas,aren gtat rl�nx ��wt . AnthonyT. Tombo I11, P.E. ntreel a.imsixeel4Mn isle eesrma6ryd0eCngNCnds eo@rrudr,ssnb:lw'rsy Cs.�a,b5e,erl,nsttisneM1e tt(dl"v lrllhifm!<deMlllF.Fleen:a�dhelCGntorfi:ll�adM1etrs; sdAigknLl.sbelais7.1!eanni knse s5tiletlensFmiuliYeJ r80083 ' Ihbdf¢tMsig:rnl6z,an. tnntesuirnuer.7PrdSsrrttia;nerieeianAfsl:BSFrrgeal34hlinzefroo(ttSprdf:keelFFl;nlS7'Jernlaeraebrnsrdpitae.lit] 4451 St. Lucie Blvd. rnRmri,ltre;wmrpneotnxricrsge�Fmzsmw:ttkFnssoecnUl�vess,Fnrtb�go<nqn,atimss!wmFrmaca'eqt:ttmr.m«Fednvlma;n:esat.nlsml. Fort Pierce, FL 34946 (oppigh -3 2616 A -I RaalBosses-AathucyT.limbo III, P.E Reprodurfin alibis document. is and tarm,is prohihicad whboutthe written ptrmissionfrom A -I Rooibosses-AethonyT. hobn'll, P.E. Truss Truss Type Qty ply F68444 HR Diagonal Hip Girder 4 A0243064 Al Roof Trusses. Fort Pierre- PI a4ada rIn innrnl=1t.,,�� o.. . o _ Job Reference(optional) - - -----•—••• S r ug o l cu eo r,,,,r. o.uze s Nug of zuib mi i eK inaustnes, Inc. Tue Apr 25 11:21:28 2017 Pagel I D:15evE3m?mEmNESyg O UyQA7zPDq?-gbeUq WhsZg54gX8 iP7 N Bs l4YXKH M pmJ QBpCKzUzNCWS '1'S 0 5-6-9 9-10-1 1-5 I 5-6-9 4-3-8 LOADING(psf) SPACING- 2-0-0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 7.0 Lumber DOL 1.25 BCLL 0,0 ' Rep Stress Incr NO BCDL 10.0 Code FBC2014frPI2007 LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 5-6-12 oc purlins. BOT CHORD Rigid ceiling directly applied or 5-11-12 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation quide. REACTIONS. (lb/size) 4 = 109/Mechanical 2 = 494/0-3-14 (min.0-1-8) 5 = 359/Mechanical Max Horz 2 = 138(LC 4) Max Uplift 4 = -98(LC 4) .2 = -377(LC 4) 5 = -333(LC 4) Max Grav 4 = 109(LC 1) 2 = 494(LC 1) 5 = 359(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-11=-1032/824, 3-11=-987/819 BOT CHORD 2-13=-872/990, 7-13=-872/990, 7-14=-872/990, 6-14=-872/990 WEBS 3-7=-207/285, 3-6=-1044/920 NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=15ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed ; end vertical left exposed; porch left exposed; Lumber DOL=1.60 plate grip DOL=1.60 , 1.Sx4 II 5-6-9 9-1 3x4 = CSI. DEFL. in (loc) Well L/d PLATES GRIP TC 0.33 Vert(LL) 0.09 6-7 >999 240 MT20 244/190 BC 0.47 Vert(TL) -0.09 6-7 >999 240 WB 0.40 Horz(TL) 0.02 5 n/a n/a Matrix -MS Weight: 39 Ib FT = O% 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s) 4 except (jt=lb) 2=377, 5=333. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 36 Ib down and 54 Ib up at 4-2-8, 36 Ib down and 54 Ib up at 4-2-8, and 61 Ib down and 106 Ib up at 7-0-7, and 61 Ib down and 106 Ib up at 7-0-7 on top chord, and 73 Ib down and 5 Its up at 1-4-9, 73 Ib down and 5 Ib up at 1-4-9, 16 Ib down and 53 Ib up at 4-2-8, 16 Ib down and 53 Ib up at 4-2-8, and 37 Ib down and 91 Ib up at 7-0-7, and 37 Ib down and 91 Ib up at 7-0-7 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25 , Plate Increase=1.25 Uniform Loads (plf) Vert: 1-4=-54, 5-8=-20 Concentrated Loads (lb) Vert: 10=2(F=1, B=1) 11=-2(F=-1, B=-1) 12=-75(F=-37, B=-37) 13=-19(F=-10, B=-10) 14=-68(F=-34, B=-34) antis-nneMey 11'*. Geva rue, rIF5S0rsa!a'o beau lub s tOcmncES tmrox{rur7}ar6751t�uEs1' mrn rnntmnp paaMrtue re,l ere, n�'srn,sh9pen.mrgp•J;admsmwr r. r„k m,u. rrt-err siersdu, m. Eel,n.ta.isr c,n[ n me t=o.rrir fhieisxuAeslassisellksseesnd.,iadnksdtLeTr,;sdzetyn:fire.'.seml7rssim>esssinass@frynueiscia;estaasAar,,hs,i.n'a?+fief,e�asu'Islsd,/,ds,dSesbskr,n;[�n&IDPeAt,seelRl.Ikkdsssss,astse,,k2uswL9ess,saTseios' .etssedfrrLnslumruifhsi,ae ere,7d6.0 .Q.mc.,ri,,A ini ssnste�ua,7,,,oa,,.n,ddii U A,Ixatikl,.Ir w.,h-ilrla. Tern-d0 itrye-r-q6:t[,,,r.0.rr,ss; �a,eigts.er�y v:r>r.ms,=etR,R[". rjrserx, , finf�A AnthonyT. Tombo ill, P.E. Ise a,afos@dger¢l6Y fart. llirdes sA,aa&sDCN2eptt!iacn/sis'dur,Atkk7.Peso,wiutnlSxmlp,;itfijsdtefnesslq na s7Ur<rde,r.<sbrpr ds, lfsae. mliAm, 9,n ns�rm, nikeesd�hns0. rims M„ =80083 9 is.smndlmsd'ce,hdnu, ntm ,nevi„kradlrt tseeat,yedgni Henry Alsstiz,LLnSss. In ma De,:p Gs�a B rIAe rY:llus Pe,isxyaLrc kde¢ tg4u: Asssh:i/'ns, ylcged'ed'na; nsss Band ¢RFL 4451 St. Lucie Blvd. (0 5s:974166d 9adLosses•AdhonyCTemho lll,P.F. Repmdodian ME$ document. in any form, is prohibited aithomAe mitten ptimissiea from A -I AaolTrasas-AethanyT. Tomho III, P.E. Fort Pierce, FL 34946 prr�9 ti s' Job Truss Truss Type Qty Ply A0243065 68444 R JACK -OPEN 10 1 Job Reference (optional) Al Roof Trusses, Fort Pierce, FL 34946, design@aitruss.com Run: 8.920 s Aug 31 2016 Print: 8.020 s Aug 312016 MiTek Industries, Inc. Tue Apr 25 11:21:29 2017 Page 1 I D:15evE3m?m Em N ESygOUyQA7zPD q?-InCs2siVJ_DxShjuyruQPVcfPjYgYJ ma NTxtVwzNCW4 -1-0-0 7-M 1-0-0 7-0-0 Dead Load Defl. = 3/16 in 30 = 7-M 7-0-0 LOADING (psf) SPACING- 2-1-4 CSI. - . DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.58 Vert(LL) -0.10 4-7 >843 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.78 Vert(TL) -0.28 4-7 >301 240 BCLL 0.0 Rep Stress Incr NO WB 0.00 Horz(TL) -0.00 3 n/a n/a BCDL 10.0 Code FBC2014frP12007 Matrix -MP Wind(LL) 0.20 4-7 >424 240 Weight: 23 lb FT = 0% LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP No.2 BRACING - TOP CHORD 2-M oc puriins (6-0-0 max.) (Switched from sheeted: Spacing > 2-0-0). BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 3 = 177/Mechanical 2 = 331/0-8-0 (min. 0-1-8) 4 = 88/Mechanical Max Horz 2 = 146(LC 8) Max Uplift 3 = -136(LC 12) 2 = -166(LC 8) Max Grav 3 = 177(LC 1) 2 = 331(LC 1) 4 = 128(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf, h=15ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 3=136, 2=166. 7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. LOAD CASE(S) Standard v.rthl-Flmu9nasll!mk. WA-1 lop! TIMSESIRLU 0311194.68 L Into In;If.Ift-Sh4d. res Ce6n axtt•Be Metw&e IGO,aIt ihTtlwrdasxilkt<,Iwn<;Icultla.L lt�T�;on t :r(,.e,sl�,�er(�I� �Fa::�IM�m�ttyre:an.,n;ry tan�El nw,leE�:v��es:na tx tll�,dcesuPermcte� �netoD��ry.ntamI. r tnl,m.p.., �.ertln�t�incuw.sar Anthony T. Tombo llI, P.E. ul nedn:sims6x sgh1lkrglsCe uspnLtlq Ab Onn,tra Onneuni.nnl ry,do nelulfvpOniae,h 5-4,0.t,i, ULN11C Ilk Irll7�kj,.h iTR�1. IQQ eirn.Idh.IDbnt.ryfsli.0 95, NtI' tali ilmg dsge,inh:elianlMna: sid'IeAx n:}rsshtlETd a 80063 ' OeHOi�Cesipxrui DYt9n. IQulns91h ie ls:lp. nlBa PuStt;ed yaied'madtizhil6ryGc�eslSa4hKe,oetinl(S¢pl6:tetili"�.,lSdU e.,dnesldr7snd�itaxe.Iniiefnnfte ngrtu;�Tin nihtrcsei Inns Ompe,?ms h:ipigeeeeetinn8mfrtnu; pins. 445! St. Lucie Blvd. .9m1vie6ssAlrlfxhaaryctgnhnuhrlietitthnhd.lieinaDeDnG7ar„hE7tlhirUiyaD�n,nLas;.ktleaL)xa�atgh!Ii4i.Nalede.i,se;mnail,dh�n. Fort Pierce, FL 34946 (opyri9ht�7�l6Adtoo(imss=s-IlrtfiocyLlanbolil,P.E. RznlodueiucalibisdommenT,inonyhtm,ispmhibitedwiThonTT6emirtenpe,missicehanAdFnalTmitzs-AnhonyMomboIII, P1, Job Truss Truss Type Qty Ply 68444 RP JACK -OPEN 4 1 A0243066 Al On,.i T., ....-.... C...� o:....... yr o.�.� �--`--^—"--- -- ,. .. _"— —' ---- —' - — Job Reference o tional k(t `i 'a v �ss.i-f f i Run: o.52rr s rug a s 20 ! o rnni: a.uzu s Aug 31 zu16 m 1 k Industries, Inc. Tue Apr 25 11:21:29 2017 Pagel I D:15evE3m?mEmN ESygOUyQA7zPDq?-InCs2sVJ—DxShjuyruQPVcaPj2RYJmaNTxtVwzNCW4 -1-0-0 7-0-0 1-0-0 7-0-0 Dead Load De0. = 1/16 in 7-0-0 Plate Offsets (X,Y)— f2:0-10-14 0-1-41 LOADING(psf) SPACING- 2-1-4 CS1. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.90 Vert(LL) 0.18 4-0 >453 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.74 Vert(TL) -0.11 4-6 >753 240 BCLL 0.0 ' Rep Stress Incr NO WB 0.00 Horz(TL) -0.00 4 n/a n/a BCDL 10.0 Code FBC2014ITP12007 Matrix -MP Weight: 29 lb FT = 0% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x6 SP No.2 6 Provide mechanical connection b others of truss ) (Y ) BRACING- to bearing plate capable of withstanding 100 lb uplift at TOP CHORD joint(s) except Gt=lb) 3=123, 2=296, 4=122. 2-0-0 oc pur ins (6-0-0 max.) 7) Graphical purlin representation does not depict the (Switched from sheeted: Spacing > 2-0-0). size or the orientation of the purlin along the top and/or BOT CHORD bottom chord. Rigid ceiling directly applied or 8-4-13 oc bracing REACTIONS. (lb/size) LOAD CASE(S) 3 = 141/Mechanical Standard 2 = 334/0-3-0 (min. 0-1-8) 4 = 119/Mechanical Max Horz 2 = 147(LC 8) Max Uplift 3 = -123(LC 8) 2 = -296(LC 8) 4 = -122(LC 8) Max Grav 3 = 141(LC 1) 2 = 334(LC 1) 4 = 146(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.0psf; h=15ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed; porch left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Plates checked for a plus or minus 0 degree rotation about its center. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Refer to girder(s) for truss to truss connections. Kraut-FI®sv Nnrytlrrer(er Cu'ili@Ci TI@iS3�SPd:E'}5EEIllliUlSEE@Ea;@@@sfafTUY laT3jt0:�atE@nY;Er lan.&:i�eesip pr_skrtutredm4rrs'w:fnrsCesip@rteusp@4;.vdRetstiaTLiuks fJ,P'_Eeseay lEettdrew. Ge4n aSmin rttela Ce ttD,n1/ Hlis"seemttsrrlehs thlikrseiln@tlppNkrd:t. lniros@:sip Ets�s{i.e,Sp:uF.pFFsiae::y heralnaryi6; ryrnauwsepto-vedll:irdmiraderSbnriyrefpaauEF.hbt M1x Nsfmd@tsieyh lrnt Eryitdvr MelU@nit,srlrtil41. I�1sdpm-srapisLlxtuiuW'ins, rw6Yw1 Anthony T. Tombo III, P.E. Morel Ees Lrss lar Wsea3x;6Ileagnsu:liyd8e@ne,Ea Cnnre�austgrCer 4etallegb::pe,iale udeAAnr�Rr7xdlirlaulSrlGgnhullnI. IIeemsrd ttirID@uE�fielinrtltleinn; hdKm; kseltry slaye,unrferaal hn isMlEe 9e rtslmfgl@td 80083 ' mt,ar�Wsigerxelra@rgr. NMss sd rNuneibC nllle srtC'resnlEakelesdnekidiy0cpes17ahirlderxelaeyE0f1Ee1Bstellr iRMSKl cardesrsl@rFaYdpisrn. iPFlidixsrk reryns3il3n Mharsdl>rLrs@ri7s,Tray R:yrEyaeaerlinrt6mh8nu, nhn 4451 St. Lucie Blvd. d1rMlsutaNErs(Wrootpcdynunmrg ETo;llmoo hrrhsl. ik ina@esip Gganrh E@TBreriliy Ossipr,srLnssincahsbeadsryl�iling. ill:ryudnsluranu sse¢@redmmL Copyright91Q16A-0AeefTmsses-Arthocyi.iemhotil,P.F. Repiodurfianaphisdomment,inany form, isprohibited-4houtthemittenpermission from A-IRzOrusses-AmhonyT.TombaIll,P.E. Fort Pierce, FL 34946 r JANUARY 17, 2017 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772409-1010 TYPICAL HIP / KING JACK CONNECTION I STDTLOI CORNERSET GENERAL SPECIFICATIONS MAX LOAD: 55 psf Roof Load, 175 mph, ASCE 7-10, Exp. B, C up to 60' Mean Roof Height and Exposure D up to 30' Mean Roof Height. Attach End Jack's w/ (4) 16d Toe Nails "@ TC & (3) 16d Toe Nails @ BC Attach King Jack w/ (3) 16d Toe ,Nails @ TC & 24" Strap w/ (6) 1 Od x 1.5" ea. end @ BC 0 ti ttach Corner Jack's d (2) 16d Toe Nails @ TC & BC (Typ) isatar,�E�s�i<d;��: ��:etaoe�l�ia�;��a�r<rQaasr►ar�v,�s�,.i�;tvx;p+�'�wa�trdsur�r�+�����,Pdy�sa:,: to ',afssisiifzeit; iEitt�,c7 igwmdiTc'�,:jd,A etaidii TvTs,u(ey (rse�r.6b16rGtdu,3esyaraL�nt ha:rq�+d�lttjittia{ lJay?�sei�asri:ii t?::dn ;(dpju,di Ci.701b A�I Cidliicstiri %A:tkaey.T:lenS¢lld p,C: Rrptcderlue cil'ais daamtss, inae,hrm,is pr�:btddubm+ih rimm pemrssiac Siia kl Rcc Attach Corner Jack's w/ (2) 16d Toe Nails @ TC & BC (Typ) V, January 17, 2017 I TYPICAL HIP / KING JACK CONNECTION I STDTL02 MIAMI-DADE CORNERSET SPECIFICATIONS MAX LOAD: 55 psf Roof Load, 175 mph, ASCE 7-10, Exp. B, C up to 60' Mean Roof Height and Exposure D up to 30' Mean Roof Height. ' A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772409-1010 Attach King and End Jack's w/ (1) LSTA12 Twist Strap @ TC w/ (10) 10d Nails Min. Per Strap and (3) 16d Toe Nails NOTE: IN ADDITION TO STRAPPING TOENAIL BOTH CHORDS OF CORNER JACKS TO CARRYING MEMBER PER THE FOLLOWING SCHEDULE: 2X4: (2) 16d.Toe Nails 2X6: (3) 16d ToeJNails LSTA12 TWIST STRAP W/ MIN. (10: MANUFACTURER'S RECOMMENDE JACK/CORNER JACK (TYP.) NOTE: CONNECTION DESIGNED IN ACCORDANCE WITH FBC 2321.6-2321.7 PROVIDING METAL STRAPPING (FLORIDA APPROVED PRODUCT) TO RESIST MIN. 700LB UPLIFT AT ALL CONNECTIONS IN HVHZ L\ i 0 ti Attach King and End Jack w/ (1) HJC26 Hanger on BC. Attach Cornea Jacks w/ (1) LSTA12 Twist Strap @ \C and BC (Typ) w/ (10) 10d Nails Min. Per Strap �e m; sa uas w.gss aaus7ias t�igWs�paa imstfha Ell=dR14ft itlq114dW.,m dalat?li: :: agLF,i._ 9epciot� sll4is daememi ino�ksa, ispaci6rteie8hovt d: rrnra peanissice heaA•[ 6ed�Goivi �RaNuryLTes.�i Cl; P.F.; �: i:: HIP OR KING JACK (TYP.) FEBRUARY 17, 2017 r � Joel.�; A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 ALTERNATE GABLE END BRACING DETAIL ALTERNATE DIAGONAL BRACING TO THE BOTTOM CHORD Y-3'MAX. DIAG. BRACE AT 1/3 POINTS IF NEEDED IT IS THE RESPONSIBILITY OF THE BLDG. DESIGNER OR THE PROJECT ENGINEER/ARCHITECT TO DESIGN THE CEILING DIAPHRAGM AND ITS ATTACHMENT TO THE TRUSSES TO RESIST ALL OUT OF PLANE LOADS THAT MAY RESULT FROM THE BRACING OF THE GABLE ENDS. HORIZONTAL BRACE (SEE SECTION A -A) TRUSSSES r 24' O.C. STDTL03 2XG DIAGONAL BRACE SPACED 48' O.C. ATTACHED TO VERTICAL WITH (4) - 16d NAILS, AND ATTACHED TO BLOCKING WITH (5) - 10d COMMONS. NAIL DIAGONAL BRACE TO PURLIN WITH TWO 16d NAILS. 2X4 PURLIN FASTENED TO FOUR TRUSSES WITH (2) - 16d NAILS EACH. FASTEN PURLIN TO BLOCKING W/ (2) - 16d NAILS (MIND. PROVIDE 2X4 BLOCKING BETWEEN THE TRUSSES SUPPORTING THE \BRACE AND THE TWO TRUSSES ON \EITHER SIDE AS NOTED. TOENAIL \ BLOCKING TO TRUSSES WITH (2) - 10d NAILS AT EACH END. ATTACH \ DIAGONAL BRACE TO BLOCKING WITH (5) - 10d COMMON WIRE NAILS. ENO WALL CEILING SHEATHING BRACING -REQUIREMENTS FOR STRUCTURAL GABLE TRUSSES STRUCTURAL GABLE TRUSSES MAY BE BRACED AS NOTED: METHOD 1: ATTACH A MATCHING GABLE TRUSS TO THE INSIDE FACE OF THE STRUCTURAL GABLE AND FASTEN PER THE FOLLOWING NAIL SCHEDULE. METHOD 2: ATTACH 2X_ SCABS TO THE FACE OF EACH VERTICAL MEMBER ON THE STRUCTURAL GABLE PER THE FOLLOWING NAILING SCHEDULE. SCABS ARE TO BE OF THE SAME SCAB ALONG SIZE, GRADE, AND SPECIES AS THE TRUSS VERTICALS. VERTICAL NAILING SCHEDULE: - FOR WIND SPEEDS 120 MPH (ASCE 7-98, 02, 05), 150 MPH (ASCE 7-10) OR LESS, NAIL ALL MEMBERS WITH ONE ROW OF 10d (.131' X 3') NAILS SPACED 6' D.C. - FOR WINO SPEEDS GREATER 120 MPH (ASCE 7-98, 02, 05), 150 MPH CASCE 7-10) NAIL ALL MEMBERS WITH TWO ROWS OF 10d (.131'X3') NAILS SPACED 6' O.C. (2X4 STUDS MINIMUM). MAXIMUM STUD LENGTHS ARE LISTED ON PAGE 1. ALl BRACING METHODS SHOWN ON PAGE 1 ARE VALID AND ARE TO BE FASTENED TO THE SCABS OR VERTICAL STUDS OF THE STANDARD GABLE TRUSS ON THE INTERIOR SIDE OF THE STRUCTURE. UKAL TRUSS Amom STRUCTURAL / AN ADEQUATE DIAPHRAGM OR OTHER METHOD OF BRACING 'N GABLE TRUSS / MUST BE PRESENT TO PROVIDE FULL LATERAL SUPPORT OF THE BOTTOM CHORD TO RESIST ALL OUT OF PLANE LOADS. THE BRACING SHOWN IN THIS DETAIL IS FOR VERTICAL/STUDS ONLY. NOTE: THIS ❑ETAIL IS TO BE USED ONLY FOR/ STRUCTURAL GABLES WITH INLAYED STUDS. TRUSSES WITHOUT INLAYED STUDS ARE NOT ADDRESSED HERE. jj� TRUSSSTANDARD GABLE / v FEBRUARY 17, 2017 STANDARD PIGGYBACK TRUSS STDTL04 CONNECTION DETAIL THIS DETAIL IS APPLICABLE FOR THE FOLLOWING WINO CONDITIONS: ASCE 7-9B, ASCE 7-02, ASCE 7-05, ASCE 7-10 WINO STANDARDS UNDER ALL A-1 ROOF TRUSSES ENCLOSURE AND EXPOSURE CONDITIONS AS LONG AS NO UPLIFT EXCEEDS 377 4451ST.LUCIE BLVD. LBS. REFER TO ACTUAL PIGGYBACK TRUSS DESIGN DRAWING FOR UPLIFTS. FORT PIERCE, FL 34946 772-409-1010 NOTE: THIS DETAIL IS VALID FOR ONE PLY TRUSSES SPACEO 24' O.C. OR LESS. PIGGYBACK TRUSS - REFER TO ACTUAL TRUSS DESIGN DRAWING FOR ADDITIONAL PIGGYBACK TRUSS INFORMATION. SPACE PURLINS ACCORDING TO THE MAXIMUM SPACING ON THE TOP CHORD OF THE BASE TRUSS (SPACING NOT TO EXCEED 24' O.CJ A PURLIN TO BE LOCATED AT EACH BASE TRUSS JOINT. ATTACH PIGGYBACK TRUSS TO THE BASE TRUSS WITH 3' X 8' TEE -LOCK MULTI -USE CONNECTION PLATES' SPACED 48' O.C. PLATES SHALL BE PRESSED INTO THE PIGGYBACK TRUSS AT 48' O.C. STAGGERED FROM EACH FACE AND NAILED TO THE BASE TRUSS WITH FOUR (4) 6d (1.5' X 0.099') NAILS IN EACH PLATE TO ACHIEVE A MAXIMUM UPLIFT CAPACITY OF 377 LBS. AT EACH 3' X B' TEE -LOCK MULTI -USE CONNECTION PLATE. (MINIMUM OF 2 PLATES) ATTACH EACH PURLIN TO THE TOP CHORD OF THE BASE TRUSS. (PURLINS AND CONNECTION BY OTHERS) BASE TRUSS REFER TO ACTUAL TRUSS DESIGN DRAWING FOR ADDITIONAL BASE TRUSS INFORMATION. y r FEBRUARY 17, 2017 .ram A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 T72AO9-1010 SE TRUSS OF 10d VALLEY TRUSS (TYPICAL) DETAIL A TRUSSED VALLEY SET DETAIL - SHEATHED GABLE END, COMMON TRUSS, OR GIRDER TRUSS GENERAL SEPCI_FICATIONS: STDTL05 1. NAIL SIZE = 3' X 0.131' = 10d 2. WOOD SCREW = 45' WS45 USP OR EQUIVALENT. 3. INSTALL SHEATHING TO TOP CHORD OF BASE TRUSSES. 4. INSTALL VALLEY TRUSSES (24' D.C. MAXIMUM) AND SECURE TO BASE TRUSSES AS PER ❑ETAIL 'A'. 5. BRACE VALLEY WEBS IN ACCORDANCE WITH THE INDIVIDUAL DESIGN DRAWINGS. 6. NAILING DONE PER NOS - 01. 7. VALLEY STUD SPACING NOT TO EXCEED 48' O.C. BASE TRUSSES WIND DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05:146 MPH WIND ❑ESIGN PER ASCE 7-10: 160 MPH MAX MEAN ROOF HEIGHT = 30 FEET ROOF PITCH = MINIMUM 3/12 MAXIMUM 6/12 CATERGORY II BUILDING EXPOSURE C WIND ❑URATION OF LOAD INCREASE:1.60 MAX TOP CHORD TOTAL LOAD = 50 PSF MAX SPACING = 24' O.C. (BASE AND VALLEY) MINIMUM REDUCED DEAD LOA❑ OF 6 PSF ON THE TRUSSES. ATTACH 2X4 CONTINUOUS #2 SYP TO THE ROOF W/ TWO USP WS45 (1/4' X 4.5') WOOD SCREWS INTO EACH BASE TRUSS. FEBRUARY 17, 2017 A-1 ROOF TRUSSES 4451 ST.LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 TRUSSED VALLEY SET DETAIL GABLE END, COMMON TRUSS, OR GIRDER TRUSS STDTL06 GENERAL P CIFI ATIONS I. NAIL SIZE = 3' X 0.131' = 10d 2. W000 SCREW = 3' WS3 USP OR EQUIVALENT. DO NOT USE DRYWALL OR DECKING TYPE SCREW. 3. INSTALL VALLEY TRUSSES (24' O.C. MAXIMUM) AND SECURE PER DETAIL 'A'. 4. BRACE VALLEY WEBS IN ACCORDANCE WITH THE INDIVIDUAL DESIGN DRAWINGS. 5. BASE TRUSS SHALL BE DESIGNED WITH A PURLIN SPACING EQUIVALENT TO THE RAKE DIMENSION OF THE VALLEY TRUSS SPACING. S. NAILING DONE PER NOS - 01. 7. VALLEY STUD SPACING NOT TO EXCEED 48' O.C. tl 11 11 11 11 11 II II 11 11 -__T__ II 11 Ii II I--- ,1 jj __ II 11 11 11 ___ 11 11 II 11 1 11 II II 11 II 11 11 11 II 11 11 11 11 11 �I 11 Ij 11 Ij 11 11 II II 11 11 11 II 11 tl 11 1 11 1j VALLEY TRUSS BASE TRUSSES li (TYPICAL) CO p I2 VALLEY TRUSS (TYPICAL) SEE DETAIL 'A' BELOW (TYP.) SE TRUSS OF 10d GABLE ENO, 1MON TRUSS, OR GIRDER TRUSS WINO DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05:146 MPH WIND DESIGN PER ASCE 7-10: 160 MPH MAX MEAN ROOF HEIGHT = 30 FEET ROOF PITCH = MINIMUM 3/12 MAXIMUM 6/12 CATERGORY II BUILDING EXPOSURE C WINO DURATION OF LOAD INCREASE:1.60 MAX TOP CHORD TOTAL LOAD = 50 PSF MAX SPACING = 24' O.C. (BASE AND VALLEY) MINIMUM REDUCED DEAD LOAD OF 6 PSF ON THE TRUSSES. ATTACH 2X4 CONTINUOUS #2 SYP TO THE ROOF W/ TWO USP WS3 (1/4' X 3') WOOD §CREWS INTO EACH BASE TRUSS. (NO SHEATHING) N.T.S. I FEBRUARY17,2017 I TRUSSED (HIGH WIND VELOCITY) AIL I STDTL07 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD, FORT PIERCE, FL 34946 772-409-1010 ATTACH 'v TRUSSES WITIF WIN❑ DESIGN PER ASCE 7-98,/ WIND DESIGN PER ASCE 7-10: MAX MEAN ROOF HEIGHT = 30 FI CATERGORY II BUILDING EXPOSURE B OR C WIND DURATION OF LOAD INCREi MAX TOP CHORD TOTAL LOAD = MAX SPACING = 24' O.C. (BASE AND VALLEY) SUPPORTING TRUSSES DIRECTLY UNDER VALLEY TRUSSES MUST BE DESIGNED WITH A MAXIMUM UNBRACEO LENGTH OF 2' - 10' ON AFFECTED TOP CHORDS. NOTES: 1. SHEATHING APPLIED AFTER INSTALLATION OF VALLEY TRUSSES. 2. THIS DETAIL IS NOT APPLICABLE FOR SPF-S SPECIES LUMBER. NON -BEVELED BOTTOM CHORD FOR BEVELED BOTTOM CHORD, CLIP MAY BE APPLIED TO EITHER FACE. CLIP MAY BE APPLIED TO THIS FACE UP TO A NON -BEVELED MAXIMUM 6/12 PITCH BOTTOM CHORO CLIP MUST BE APPLIED TO THIS FACE WHEN PITCH EXCEEDS 6/12 (MAXIMUM 12/12 PITCH) FEBRUARY 17, 2017 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 STANDARD GABLE END DETAIL TYPICAL 2X4 L-BRACE NAILED TO 2X4 VERTICALS W/IOd NAILS, 6' O.C. VERI STUD SECTION 9-8 T72-409-1010 I TRUSS GEOMETRY AND CONDITIONS SHOWN ARE FOR ILLUSTRATION ONLY. DIAGONAL BRACE 4' - 0' O.C. MAX. SEE INDIVIDUAL ENGINEERING DRAWINGS FOR TRUSS DESIGN CRITERIA. STDTL08 VERTICAL 2X6 SP OR SPF STUDW2X4 #2 DIAGONAL BRACE (4) - 16d NAILS16d NAILS SPACED 6' O.C. (2) IOd NAILS INTO 2X62X6 SP OR SPF #2 2X4 SP OR SPF #2 HORIZONTAL NAILED TO RTICALS SECTION A -A W/(4) - IOd NAILS 12 PROVIDE 2X4 BLOCKING BETWEEN QTHE FIRST TWO TRUSSES AS NOTED. VARIES TO COMMON TRUSS * TOENAIL BLOCKING TO TRUSSES WITH (2) - IOd NAILS AT EACH END. ATTACH DIAGONAL BRACE TO BLOCKING WITH (5) - IDd NAILS (4) 8d NAILS MINIMUM, ROOF 3X4= PLYWOOD SHEATHING I SHEATHING 2X4 STO SPF BLOCK 9c v DIAGONAL BRACING L - BRACING REFER REFER TO SECTION A -A TO SECTION B-8 24' MAX. / NOTE: / 1. MINIMUM GRADE OF #2 MATERIAL IN THE TOP AND BOTTOM CHORDS. 10d 2. CONNECTION BETWEEN BOTTOM CHORD OF GABLE END TRUSS AND WALL TO 12' MAX. NAILS BE PROVIDED BY PROJECT ENGINEER OR ARCHITECT. 3. BRACING SHOWN IS FOR INDIVIDUAL TRUSS ONLY. CONSULT BLDG. ARCHITECT OR ENGINEER FOR TEMPORARY AND PERMANENT BRACING OF ROOF SYSTEM. 4. 'L' BRACES SPECIFIED ARE TO BE FULL LENGTH, SPF OR SP #3 OR BETTER WITH ONE ROW OF 10d NAILS SPACED 6' O.C. TRUSSES @ 24' O.C. 5. DIAGONAL BRACE TO BE APPROXIMATELY 45 DEGREES TO ROOF DIAPHRAGM / AT 4' - 0' O.C. 6. CONSTRUCT HORIZONTAL BRACE CONNECTING A 2X6 AND A 2X4 AS SHOWN 2X6 DIAGONAL BRACE WITH 16d NAILS SPACED 6' O.C. HORIZONTAL BRACE TO BE LOCATED AT SPACED 48' O.C. ATTACHED THE MIDSPAN OF THE LONGEST GABLE STUD. ATTACH TO VERTICAL GABLE TO VERTICAL WITH (4) - STUDS WITH (3) 10d NAILS THROUGH 2X4 (REFER TO SECTION A -A) 16d NAILS, AND ATTACHED 7. GABLE STUD ❑EFLECTION MEETS OR EXCEEEDS L/240. TO BLOCKING WITH (5) - B. THIS DETAIL DOES NOT APPLY TO STRUCTURAL GABLES. OIAG. BRACE IOd NAILS. 9. DO NOT USE FLAT BOTTOM CHORD GABLES NEXT TO SCISSOR TYPE AT 1 /3 POINTS TRUSSES. IF NEEDED 10.10d AND 16d NAILS ARE 0131'X3.0' AND 0131'X3.5' COMMON WIRE NAILS HORIZONTAL BRACE 11. RESPECTIVELY. SOUTHERN PINE LUMBER DESIGN VALUES ARE THOSE EFFECTIVE 06-01-12 (SEE SECTION A -A) BY SPIB/ALSC. MINIMUM STUD SIZE SPECIES AND GRADE STUD SPACING WITHOUT BRACE 2X4 L - BRACE DIAGONAL BRACE (2) DIAGONAL BRACES AT 1/3 POINTS MAXIMUM STUD LENGTH 2X4 SP #31 STUD 12' O.C. 3-8-10 5-6-11 6.6-11 11-1-13 2X4 SP #31 STUD 16' O.C. 3-3-10 4-9-12 6.6-11 9-10-15 2X4 SP #31 STUD 24' O.C. 2-8.6 3-11-3 5-4-12 8-1-2 2X4 SP 42 12' O.C. 3-10-15 5-6-11 6-6-11 11-8-14 2X4 SP #2 16' O.C. 3-6-11 4-9-12 6-6-11 10-H 2X4 SP #2 24" O.C. 34A 3-11-3 6-2-9 9-3-13 DIAGONAL BRACES OVER G' - 3' REQUIRE A 2X4 T-BRACE ATTACHED TO ONE EDGE. ❑IAGONAL BRACES OVER 12' - 6' REQUIRE 2X4 I -BRACES ATTACHED TO BOTH EDGES. FASTEN T AND I BRACES TO NARROW EDGE OF DIAGONAL BRACE WITH IOd NAILS G' O.C., WITH 3' MINIMUM END DISTANCE. BRACE MUST COVER 907 OF DIAGONAL LENGTH. T OR I BRACES MUST BE 2X4 SPF #2 OR SP #2. MAX MEAN ROOF HEIGHT = 30 FEET EXPOSURE B OR C ASCE 7-10 190 MPH STUD DESIGN IS BASED ON COMPONENTS AND CLADDING. DURATION OF LOAD INCREASE :1.60 CONNECTION OF BRACING IS BASED ON MWFRS. END WALL ,7 y I FEBRUARY 17, 2017 T-BRACE / I -BRACE DETAIL I STDTL09 WITH 2X BRACE ONLY ..............: NOTES: T—BRACING / I —BRACING TO BE USED WHEN CONTINUOUS LATERAL BRACING IS IMPRACTICAL. T—BRACE / I —BRACE MUST COVER 90% OF WEB LENGTH. w! THIS DETAIL NOT TO BE USED TO CONVERT T—BRACE / I —BRACE WEBS TO �.; CONTINUOUS LATERAL BRACED WEBS. A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 NAILING PATTERN T-BRACE SIZE NAIL SIZE NAIL SPACING 2X4 OR 2X6 OR 2X8 10d 6" O.C. NOTE: NAIL ALONG ENTIRE LENGTH OF T—BRACE / I —BRACE (ON TWO—PLY TRUSSES NAIL TO BOTH PLIES) \\ \ NAILS BRACE SIZE FOR ONE -PLY TRUSS SPECIFIED CONTINUOUS ROWS OF LATERAL BRACING WEB SIZE 1 2 2X3 OR 2X4 2X4 T—BRACE 2X4 I —BRACE 2X6 2X6 T—BRACE 2X6 I —BRACE 2X8 2X8 T—BRACE 2X8 I —BRACE BRACE SIZE FOR TWO-PLY TRUSS SPECIFIED CONTINUOUS ROWS OF LATERAL BRACING WEB SIZE 1 2 2X3 OR 2X4 2X4 T—BRACE 2X4 I —BRACE 2X6 2X6 T—BRACE 2X6 I —BRACE 2X8 2X8 T—BRACE 2X8 I —BRACE T—BRACE / I —BRACE MUST BE SAME SPECIES AND GRAOE (OR BETTER) AS WEB MEMBER. NAILS WEB NAILS I -BRACE 1( NAILS WEB T-BRACE SECTION DETAILS FEBRUARY 17, 2017 LATERAL BRACING RECOMMENDATIONS ` r STDTL10 TO MINIMIZE VIBRATION COMMON TO ALL SHALLOW FRAMING SYSTEMS, 2X6 'STRONGBACK' IS RECOMMENDED, LOCATED EVERY 8 TO 10 FEET ALONG A FLOOR TRUSS. "'� NOTE 1: 2X6 STRONGBACK ORIENTED VERTICALLY MAY BE POSITIONED DIRECTLY UNDER THE --- ....-...--....... *e! TOP CHORD OR DIRECTLY ABOVE THE BOTTOM CHORD, SECURELY FASTENED TO THE TRUSS USING ANY A-1 ROOF TRUSSES OF THE METHODS ILLUSTRATED BELOW. 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 NOTE 2: STRONGBACK BRACING ALSO SATISFIES THE LATERAL BRACING REQUIREMENTS FOR THE 772-409-1010 BOTTOM CHORD OF THE TRUSS WHEN IT IS PLACED ON TOP OF THE BOTTOM CHORD, IS CONTINUOUS FROM END TO END, CONNECTED WITH A METHOD OTHER THAN METAL FRAMING ANCHOR, AND PROPERLY CONNECTED, BY OTHERS, AT THE ENDS. INSERT WOOD SCREW THROUGH OUTSIDE FACE OF CHORD INTO EDGE OF STRONGBACK (00 NOT USE METAL FRAMING ATTACH TO VERTICAL ATTACH TO VERTICAL USE DRYWALL TYPE SCREWS) ANCHOR TO ATTACH WEB WITH (2) - 10d SCAB WITH (3) - 10d r TO TOP CHORD NAILS (0.131' X 3') NAILS (0.131' X 3'). I ATTACH TICS TO VERTICAL 10d WEB WITH 3) BLOCKING BEHIND THE VERTICAL WEB IS RECOMMENDED WHILE NAILING THE STRONGBACK USE METAL FRAMING ANCHOR TO ATTACH TO BOTTOM CHORD TRUSS ATTACH TO VERTICAL WEB WITH (3) - 10d NAILS (0131' X 3') ATTACH 2X4 VERTICAL TO FACE OF TRUSS. FASTEN TO TOP AND BOTTOM CHORD WITH (2) - 10d NAILS (0.131' X 3') IN EACH CHORD ATTACH TO VERTICAL SCAB WITH (3) - 10d NAILS (0.131' X 3') Gfal➢ DESIGNED BY OTHERS. IF SPLICING IS NECESSARY, USE A 4' -u0' LONG SCAB CENTERED ON THE SPLICE AND JOINED WITH (12) - 10d NAILS (0131' X 3') EQUALLY SPACED. ALTERNATE METHOD OF SPLICING: OVERLAP STRONGBACK MEMBERS A MINIMUM OF 4' - 0' AND FASTEN WITH (12) - 10d NAILS (0.131' X 3') STAGGERED AND _EQUALLY SPACED (TO BE USED ONLY WHEN STRONGBACK IS NOT ALIGNED WITH A VERTICAL). ATTACH TO CHORD WITH (2) #12 X 3' WOOD SCREWS (0.216' DIA.) INSERT SCREW THROUGH OUTSIDE FACE OF CHORD INTO EDGE OF STRONGBACK (DO NOT USE DRYWALL TYPE SCREWS) .00KING Y OTHERS) tp a _{ FEBRUARY 17, 2017 A-1 ROOF TRUSSES 4461 ST. LUCIE BLVD. FORT PIERCE. FL 34946 772-409-1010 LATERAL TOE -NAIL DETAIL NOTES: 1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 45" WITH THE MEMBER AND MUST HAVE FULL WOOD SUPPORT (NAIL MUST BE DRIVEN THROUGH AND EXIT AT THE BACK CORNER OF THE MEMBER END AS SHOWN). 2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 3. ALLOWABLE VALUE SHALL BE THE LESSER VALUE OF THE TWO SPECIES FOR MEMBERS OF DIFFERENT SPECIES. TOE -NAIL SINGLE SHEAR VALUES PER NOS 2001 (LB/NAIL) DIA SP OF HF SPF SPF-S .131 88.0 80.6 69.9 68.4 59.7 z .135 93.5 85.6 74.2 72.6 63.4 0 J .162 108.8 99.6 86.4 84.5 73.8 Ni 128 74.2 67.9 58.9 57.6 50.3 0 Z O J .131 75.9 69.5 60.3 59.0 51.1 to .148 81.4 74.5 64.6 63.2 52.5 N h VALUES SHOWN ARE CAPACITY PER TOE -NAIL. APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED. EXAMPLE: (3) - 16d NAILS (0162' DIA. X 3.5') WITH SPF SPECIES BOTTOM CHORD FOR LOAD DURATION INCREASE OF 1.15: 3 (NAILS) X 845 (LB/NAIL) X 1.15 (DOL) = 291.5 LB MAXIMUM CAPACITY ANGLE MAY VARY FROM 30' TO 60' 45.00' ANGLE MAY VARY FROM 30' TO 60' STDTL11 THIS DETAIL IS ONLY APPLICABLE TO THE THREE END DETAILS SHOWN BELOW. VIEWS SHOWN ARE FOR ILLUSTRATION PURPOSES ONLY. SIDE VIEW (2X3) 2 NAILS NEAR SIDE NEAR SIDE SIDE VIEW (2X4) 3 NAILS NEAR SIDE NEAR SIDE NEAR SIDE 45.00' SIDE VIEW (2X3) 2 NAILS NEAR SIDE NEAR SIDE NEAR SIDE NEAR SIDE ANGLE MAY VARY FROM 30' TO 60' 45.00° :.s FEBRUARY 17, 2017 1 UPLIFT TOE -NAIL DETAIL I STDTL12 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 THIS DETAIL SHALL BE USED FOR A CONNECTION RESISITING UPLIFT FORCES ONLY. BUILDING DESIGNER IS RESPONSIBLE FOR LOADS IN OTHER DIRECTIONS. NOTES: 1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 30• WITH THE MEMBER AND STARTED 1/3 THE LENGTH OF THE NAIL FROM THE MEMBER END AS SHOWN. 2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 3. ALLOWABLE VALUE SHALL BE BASEO ON THE SPECIE WITH LOWER NAIL CAPACITY BETWEEN THE TWO MEMBERS IN THE CONNECTION. TOE -NAIL WITHDRAWAL VALUES PER NOS 2005 (LB/NAIL) DIA. SP DF HF SPF SPF-S 0 .131 59 46 32 30 20 z O J .135 60 48 33 30 20 Lfl .162 72 - 58 39 37 25 J 2 F_ 0 .128 54 42 28 27 19 z Z O J .131 55 43 29 28 19 W .148 62 48 34 31 21 J J N Q M Z .120 51 39 27 26 17 z .128 49 38 26 25 17 O .131 51 39 27 26 17 J M .148 57 44 31 28 20 VALUES SHOWN ARE CAPACITY PER TOE -NAIL. APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED. EXAMPLE: (3) - 16d NAILS (0162' DIA. X 3.5') WITH SPF SPECIES TOP PLATE FOR WIND OOL OF 1.33: 3 (NAILS) X 37 (LB/NAIL) X 133 (OOL FOR WIND) = 148 LB MAXIMUM ALLOWABLE UPLIFT REACTION DUE TO WIND FOR WIND DOL OF 1.60: 3 (NAILS) X 37 (LB/NAIL) X 1.60 (OOL FOR WIND) = 177 LB MAXIMUM ALLOWABLE UPLIFT REACTION DUE TO WIND IF THE UPLIFT REACTION SPECIFIED ON THE TRUSS DESIGN DRAWING EXCEEDS 147 LEIS (177 LBS) BUILDING DESIGNER IS RESPONSIBLE TO SPECIFY A DIFFERENT CONNECTION. *** USE (3) TOE -NAILS ON 2X4 BEARING WALL *** USE (4) TOE -NAILS ON 2X6 BEARING WALL NEAR SIDE FAR Sl SIDE VIEW IE TOP PLATE OF WALL VIEWS SHOWN ARE FOR ILLUSTRATION PURPOSES ONLY END VIEW L NAIL NAIL I FEBRUARY 5, 2016 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772409-1010 I.0x4 TYP 2x2 NAILER ATTACHMENT I STDTL13 2x2 NAILER ATTACHMENT GENERAL SPECIFICATIONS MAX LOAD: 55 psf Roof Load, 170 mph, ASCE 7-10, 29'-0" Mean Height, Exp. B, C or D. April 11, 2016 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 TYPICAL ALTERNATE BRACING DETAIL FO EXTERIOR FLAT GIRDER TRUSS (4) 12d TRUSS 2411 O.C. UPLIFT CONNECTION (SEE ROOF TRUSS) EXTERIOR FLAT GIRDER 12 VARIES STDTLI4 (4) 12d MAX 30" (2'-6") 2x6 #2 SP (Both Faces) 24" O.C. SIMPSON HS n FEBRUARY 17, 2017 ■■.�.. A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772409-1010 STANDARD REPAIR DETAIL FOR BROKEN CHORDS, WEBS, AND I STDTL15 DAMAGED OR MISSING CHORD SPLICE PLATES TOTAL NUMBER OF NAILS EACH SIDE OF BREAK X (INCHES) MAXIMUM FORCE (LBS) 157 LOAD DURATION SP OF SPF HF 2X4 2X6 2X4 2X6 2X4 2X6 2X4 2X6 2X4 2X6 20 30 24" 1706 2559 1561 2342 1320 1980 1352 2028 26 39 30" 2194 3291 2007 3011 1697 2546 1738 2608 32 48 36' 2681 4022 2454 3681 2074 3111 2125 3187 38 57 42" 3169 4754 2900 4350 2451 3677 2511 3767 44 66 48" r3657 5485 3346 5019 2829 4243 2898 4347 * DIVIDE EQUALLY FRONT AND BACK ATTACH 2X_ SCAB OF THE SAME SIZE AND GRADE AS THE BROKEN MEMBER TO EACH FACE OF THE TRUSS ( CENTER ON BREAK OR SPLICE) WITH 10d NAILS (TWO ROWS FOR 2X4, THREE ROWS FOR 2X6) SPACED 4' O.C. AS SHOWN (.131' DIA. X 3')_ STAGGER NAIL SPACING FROM FRONT FACE AND BACK FACE FOR A NET 2' O.C. SPACING IN THE MAIN MEMBER. USE A MIN. 3' MEMBER END DISTANCE. THE LENGTH OF THE BREAK (C) SHALL NOT EXCEED 12'. (C=PLATE LENGTH FOR SPLICE REPAIRS) THE MINIMUM OVERALL SCAB LENGTH REQUIRED (L) IS CALCULATED AS FOLLOWS: L = (2) X + C •10d NAILS NEAR SIDE + 10d NAILS FAR SIDE - BREAK s TRUSS CONFIGURATION AND BREAK LOCATIONS FOR ILLUSTRATIONS ONLY THE LOCATION OF THE BREAK MUST BE GREATER THAN OR EQUAL TO THE REQUIRED X DIMENSION FROM ANY PERIMETER BREAK OR HEEL JOINT AND A MINIMUM OF 6' FROM ANY INTERIOR JOINT (SEE SKETCH ABOVE). DO NOT USE REPAIR FOR JOINT SPLICES NOTES: 1. THIS REPAIR DETAIL IS TO BE USED ONLY FOR THE APPLICATION SHOWN. THIS REPAIR DOES NOT IMPLY THAT THE REMAINING PORTION OF THE TRUSS IS UNDAMAGED. THE ENTIRE TRUSS SHALL BE INSPECTED TO VERIFY THAT NO FURTHER REPAIRS ARE REQUIRED. WHEN THE REQUIRED REPAIRS ARE PROPERLY APPLIED, THE TRUSS WILL BE CAPABLE OF SUPPORTING THE LOADS INDICATED. 2. ALL MEMBERS MUST BE RETURNED TO THEIR ORIGINAL POSITIONS BEFORE APPLYING REPAIR AND HELD IN PLACE DURING APPLICATION OF REPAIR. 3. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 4. WHEN NAILING THE SCABS, THE USE OF A BACKUP WEIGHT IS RECOMMENDED TO AVOID LOOSENING OF THE CONNECTOR PLATES AT THE JOINTS OR SPLICES. S. THIS REPAIR IS TO BE USED FOR SINGLE PLY TRUSSES IN THE 2X_ ORIENTATION ONLY. G. THIS REPAIR IS LIMITED TO TRUSSES WITH NO MORE THAN THREE BROKEN MEMBERS. FEBRUARY 11, 2017 1 SCAB APPLIED OVERHANGS I STDTL16 ................... I A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772409-1010 TRUSS CRITERIA: LOADING: 40-10-0-10 DURATION FACTOR: 115 SPACING: 24' O.C. TOP CHORD: 2X4 OR 2X6 PITCH: 4/12 - 12/12 HEEL, HEIGHT: STANDARD HEEL UP TO 12' ENERGY HEEL ENO BEARING CONDITION 11111r*5 1. ATTACH 2X-SCAB (MINIMUM #2 GRADE SPF, HF, SP, OF) TO ONE FACE OF TRUSS WITH TWO ROWS OF 10d COMMON WIRE NAILS 048' OIA. X 3') SPACED G' O.C. 2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 3. WHEN NAILING THE SCABS, THE USE OF A BACKUP WEIGHT IS RECOMMENDED TO AVOID LOOSENING OF THE CONNECTOR PLATES AT THE JOINTS OR SPLICES. 2X SC NOTE: TRUSS BUILT WITHOUT AN OVERHANG. THIS DETAIL IS NOT TO BE USED WHEN OVERHANG HAS BEEN BROKEN OFF. IMPORTANT THIS DETAIL TO BE USED ONLY WITH TRUSSES (SPANS LESS THAN 409 SPACED 24' O.C. MAXIMUM AND HAVING PITCHES BETWEEN 4/12 AND 12/12 AND TOTAL TOP CHORD LOADS NOT EXCEEDING 50 PSF. TRUSSES NOT FITTING THESE CRITERIA SHOULD BE EXAMINED INDIVIDUALLY. REFER TO INDIVIDUAL TRUSS DESIGN FOR PLATE SIZES AND LUMBER GRADES