HomeMy WebLinkAboutProduct Approval Roofing Underlaymentsl
� +�-,� "`3 �";:� �'a!';1 � .e�hro'3' a_ y � � �rC4 �x•Y+�. +y.. �� � 4yf}�
...� ,.,�.�. �` �': --:�` _.�;' . � '• ��no,€t- .anon, �s>i�.- use o7ztsi
FiCi•i��
= r�x Product Approval
m USER: Public User
Product Approval Menu > Product or Aonilotion Search > Application list > Application Detail
m rt�;7, FL#
Application Type
' Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
,Authorized Signature
'Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category' ,
Subcategory
Compiiance� Method
FL9777-R9
Revision
2014
Approved
Owens-Corning
211
ST. LUCIE COUNTY
BUILDING DIVISION
FOM
REVIEVN D BYOO I'_ oil
DATE — _
FLANS AND PERMIT
MUST BE KEPT ON JOB OR
NO INSPECTION WILL SE MADE
One Owens. Corning Parkway
Toledo,. OH 43656
(740.) 404=7829-
greg-keeler@owe'nscorning.com
Greg Keeler
greg.ketiler@owenscorn'ing.com
THESE PLANS AND ALL PROPOSED WORK
ARE SUPUE CT TO ANY COr EC T IONS
REQUIRED Ur FIELD INSPECTORS THAT
MAY BE N110ES'SARY IN ORDER 1.0
COMPLY WITH A" AFPQQ4L4000,
.g j
Roofing
Underlaymehts
Evaluation Report from a Florida Registered Architect or a Licensed F
Professional Engineer
—' Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Zachary R. Priest
Evaluation Report
Florida License PE-74021.
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/31/2020.
Validated By Locke Bowden
Validation Checklist - Hardcopy Received
i..
Certificate of Independence FL9777 R-9C0I OCR14002 6a FBC 2014 Evaluation Report Wea+hei
'Non-HVHZ .FINAL,odf
Referenced Standard and Year (of Standard)
Standard
Year
7t�� 'I
1111 I'A�.)TE ERS ORA 1AA0H1`0ENTS
A
20.09
ASTP7 OPHE RESPONSIBILITY OF THE
zoos
107 CONTRACTOR OF RECORD
UL'1995
U L'189
2004
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted
04/12/2017
Date' Validated
04/12/2'017
Date Pending. FBC Approval
0,4/13/2017
Date.Approved
06/.13/201.7
Summ'arvof Preduets
FL #
Model, Number or.Name
Description
9777.1
Weatherlock G
Weatherproofing 'Underlayment
Limits of Use
Installation Instructions
Approved for.,use in; HVHZ:. No
'FL9777 R9 II OCR14002 6a FBC 2014 Evaluation Renor
Weatherlock Nan-HVHZ FINAL.bdf
Approved, for use outside HVHZ: Yes
impact Resistant:. N/A
Verified 6y: Zachary R. Priest 7402-1
i. Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
'
Evaluation Reports
FL9777 R9 AE OC1114002 ha. FBC 2014 i=valuailon Rep
Weatherlock Non HVHZ:FINAL.pdf
Created by Independent third Party Yes
.9777.2
WeatherLock G (High' Tear)
"Weatherproofing. Underlayment
.Limits of, Use,
Installation Instructions:
Approved for use q HVHZ; No
F49777 R9 II OCRI4002.6a FBC 201-4 Evaluation.Repo
`Weatherlock Non-HVHZ FINAL Of
Approved for use outside: HVHZ; Yes
Impact Resistant: N/A
Verified By: Zachary R: Priest PE-7402.1
Design Pressure: N/A
Created by Independent Third Party.: Yes
Other: See evaluationreport for limits of use.
'.Evaluation Reports
FL9777 R9 AE OCR140D2 ,6a FBC 2014 Evaluation Repo
W/ Non-HVHZ,FINAL.pdf
atheriock
Created by Independent Third Party: Yes
9777.3
Weatherloak'MAT
Waterproofing. Underlayment
Limits of Use.
' Installation Instructions.
Approved for use in HVHZ: Yes;
FL9777 R9 II OCR14002 6tr FBC 2014 Evaluation Repor
Weatherlock HVHZ.pdf
Approved for use outside.HVHZ: No
Impact Resistant:'N/A
Verified By:, Zachary. R. Priest 74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
F0777'R9 AEOCRI4002'6b ER-C 2014 Evaluation Repc
Weatherlock HVHZ:pdf
Creat d by Independent Third Party; Yes
9777.4
Weatherlock MAT,; I.
Waterproofing'.Underlayment-
' L'imits of Use
Installation Instructions
Approved #or. use In HVHZ: No
FI V77 R9IT OCR14002 5a FBC 2014 Evaluation Reoor
Approved for use,outsde HVHZ: Yes
Weatherlock Non-HVHZ FINAL pdf
I.mpact;Resistant: N/A
Verified By: Zachary R. Priest 74021
Design Pressure: N/A
'Created by Independent third Party: Yes
Other:•See evaluation report:for limits of use;,
Evaluation Reports
I1 W4 'R9.AE, OCR14002 6a FBC 2014 Evaluation Rep
Weatherlock Non-HVHZ.. FINAL Ddf
I
Created by Independent Third: Party: Yes
f 9777.5r
WeatherLock.: Metal
Weatherproofing Underlayment
f�Limits of Use,
Installation Instructions
Approved for use in HVHZ: No I
Approved for use outside. HVHZ; Yes
FL9777' R9 II' 06R14002 6a FBC 2014 Evaluation Reoor
Weatherlock Non-HVHZ FINAL.pdf
Verified By: Zachary R. Priest PE-7,4021
impact Resistant: N/A
Design Pressure: N/A
Created by.Independent Third Party:'Yes
Other: See evaluation report for limits of use.
Evaluation Reports
1FL9777 R9 AE' OCR14002 6a FBC 2014 Evaluation Repo
. f .
Yes
7-77.6 WeatherLock Metal I W,.eatherproofing Underlayment
Limits of Use Installation Instructions
Approved for use in HVHZ Yes FL9777 R9 .II OCRI4002.6b_F134t 2014 Evaluation Regor
Approved for use outside HVHZ:_ No Weatherlock HVHZ:adf
Impact Resistant: NSA Verified By; Zachary lt; Priest PE-74021.
Design Pressure: N/A Created by Independent Third Party: Yes
j Other: See evaluation. report for limits of use. Evaluation Reports
Third.Party: Yes.
't9777:7 Weatheryr4d kf5 ec`ialt Tile I k bp, - Meal Weatherproofing Underlayment
Limits of. Use Installation Instructions -�
Approved 'for use in HVHZ: No FL9777 R9 .II OCRI4002.6a•FBC 2014 Evaluation Repor
f Approved for use outside_HVHZ; Yes We Eherlock..Non-WHZ JNAL.odf
Impact Resistant:'N%A Verified By: Zachary R Priest
Design Pressure: +0/-105' Created by Independent Third Party: Yes
Other•. See evaluation report for limits of use. Evaluation Reports
Party: Yes:
OatK stox&
Contact lls :; 2601 Blair Stone Road .Tallahassee FL- 32399.Phone: 850-4874824
The. State of. Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Prlyacv Statement c Accessibility Statement':: Rerund Statement
.,
Under Florida,law, email addresses are public "records. •If ydu:do not want your a -mall address released. in response to a p(iblic-records request, do not-send-ele
maii;to. this entity. Instead, contact the office by phone or by tradltional;mail. If you Piave -any questions,•please contact-650.487.1395. *Pursuagt'to Secti
455.2750)i Florida Statutes, effective october 1,,Z012, licensees license&under Chapter 455, F.S. must provide the Departnei nt with an email address if the
one: The emalisprovided'may be used for official communication with the.,llcen'see.,Hgweyer'email addressessare,public record. If you do not wish to supplya F'.
address, please provide the Department.with,anemail-address�which can be made available to the public. To detemiine:if you are.a'Iicensee;vnder Cbaptee
. ,please dic Pik .
Product A , c..
pproval Aecepts;
MM
In, 970 . e«F `. E.
Credit'Card
. Safe
k CREEK
TECHNICAL. SERVICES, LLC.
Certificate of Authorization No. 29824
17520 Edinburgh Drive
Tampa, FL 33647
(813)480-3421
EVALUATION REPORT FLORIDA BUILDING CODE 5T" EDITION (2014)
Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC Issued April 12, 2017
1 Owens Corning, Parkway
Toledo, OH 43657
(800)438-7465
www.owenscorn ing.com
Manufacturing Location: Brentwood, NH
Houston, TX
Quality Assurance: UL LLC (Q'UA9625)
SCOPE
Category: Roofing
Subcategory.Underlayments
Code Sections: 1504.3.1,15072.4, 1507.2.8, 1507.2.9.2, 1507.3.3, 1507::4:5, 1507.4.5.2i 1507.5.3;
1507;5.3.2, 1507.7.3, 1507:7:3.2
Properties: Physical Properties
REFERENCES
Ent
Report No.
Standard
Year
PRI Construction Materials Technologies (TST6049)
NEI-039-02-01
ASTM D 1970
2009
PRI Construction Materials Technologies (TST6049).
NEI-042-02-01REV2
ASTM D 1970
2009
PRI Construction Materials Techrologies (TST6049)
NEI-045-02-01
TAS 103
1995
PRI Construction Materials Technologies (TST6049)
NEI-045-02-01
ASTM G 155.
2005.a
PRI Construction Materials Technologies (TST6049)
NEI=053-02-01
TAS 103
1995
PRI Construction Materials Technologies (TST6049)
NEI-053-02-01
ASTM G' 155
2006a
PRI Construction Materials Technologies••(TST6049). ,
NEF093-02-02
ASTM D 1970
2009
PRI Construction Materials Technologies,(TST6049) '
OCF;213-02-01
ASTM D 1623
2009
PRI Construction Materials Technologies'(rST6049)
OCF-237-02-61
UL 1897
2004
PRI Construction Materials Technologies (TST5878)
OCF-252-02-01
ASTM D 4798
200.1,
PRI Construction Materialste' chnologies (TST6049)
OCF-252-02-01
ASTM,D 1970
2009
PRI Construction Materials Technologies (TST5878)
OCF=253.02-02
ASTM D 1970
2009
PRI Constrbctlon. Materials, Technologies (TST(5049)
OCF=272-02-01
TAS 103
1995
PRI Construction MaterialsTechnolagies (TST6049)
OCF-296-02-02
ICC-ESAC 188"
2012
ICC-ES:AC 48
2012
PRI Construction Materials Technologies (TST6049)
OCF-297-02-01.1
ASTM D 1970
2009
'Determined to be equivalent to ASTM D.226-06; Type l and it
OCR14002.6a
This evaluation
Technical Servi
This evaluation
specifically add
M
FL9777-R9 Page 1 6f 4'
rt Is provided for State otFlorida product approval. under 61G20:3.. iThe manufacturer shalt notify CREEK
.LC of any product changes or quality assurance ohan'ges throughout the duration for which this report is valid..
rt. does not express nor imply warranty, installation, recommended use, or other product attributes that are not
d herein.
j` CREEK.
TECHNICAL SERVICES, LLC,
PRODUCT DESCRIPTION AND LIMITS OF USE
OWENS CORNING: ROOFING AND ASPHALT LLC
WeatherLock® Self -Sealing Ice & Water Barriers
WeatherLock®-G WeatherLock® G, is an. ASTM D 1970 self-adhesive underlayment constructed: from SBS
(Brentwood, NH) modified asphalt, a fiberglass mat reinforcement and surfaced with granules. The
product is supplied in 2-sq. rolls with nominal dimensions of 3-ft x 66;7-ft:
WeatherLock( G is permitted to be used with mechanically fastened asphalt shingles,
wood shakes or shingles,_ and slate roofing as prescribed in the FBC. Exposure on the
roof deck shali be limited to a maximum a0 days.
WeatherLock® Mat WeatherLockO Mat is an ASTM D 1970 self-adhesive underlayment constructed from
(Brentwood, NH or SBS modified asphalt,with a fiberglass mat reinforcement. The. product is supplied' in 1-
Houston, 7X) sq. rolls with nominal dimensions of 3-ft x 33.3-ft and 2 sq.. rolls with nominal dimensions
of 3-ft x 66.7-ft.
WeatherLockl& Mat is permitted to be used with mechanically fastened asphalt shingles,
wood shakes or shingles, and slate, roofing as prescribed in the FBC. Exposure on the
roof deck shall be limited to a maximum 30 days.
WeatherLock® Metal WeatherLock® Metal is an ASTM D 1970 self-adhesive underlayment constructed from
(Brentwood, NH) SBS modified asphalt with a fiberglass mat reinforcement and pi astic film surface. The
product is supplied in 2.0 sq. rolls with nominal dimensions of 3-ft x 66.74L
WeatherLock® Metal is permitted -to be used with mechanically 'fastened asphalt
shingles, metal roof panels or shingles,, wood shakes or shingles, and slate roofing as
prescribed in the FBC. Exposure on the roof deck shall be limited to a maximum 90
days.
WeatherLock® WeatherLock@ Specialty Tile & Metal is an ASTM D 1970 self-adhesive underlayment
Specialty Tile & Metal constructed from SBS, modified: asphalt and surfaced with a non -woven polyester fabric.
(Brentwood, NH) The product is supplied in 2.14 sq.:rolls,with nominal dimensions -of 3-ftx 71,3-ft.
I, P
VIleatherLock� Specialty Tile & Metal is permi led, to. be used with mechanically fastened
asphalt shingles, clay or concrete til ��metal roo +" f,psanelsor shingles, wood shakes or
shingles, and, slate roofing as prescnbed m,the-FBC'-WeatherLock® Specialty Tile &
Metal is per itted to be used with adhered clay or concrete file roof using either WTM
2-Component Foam Roof Tile Adhesive AHA60 (3M Company) or TILE BONDTM Roof
Tile Adhesive (The Dow Chemical Company,), Fxpos ro ck b it „,
to a maximum 90 days.
The maximum roof slope shall be- when used wi clay er�oacrete t s ops
without battens. Tile shall be stored on battens for roof slopes greater than 6.12. Tiles
shall not be stacked 'greater 10 tiles per stack,
WeatherLock® G (High 1NgatherLock® G (High. Tear) is a, self-gdhere. d, ,undertayment used as an alternative,to
Tear) ASTM D 226, Type I or Type II roofing felt and ASTM D 1970. self -adhering polymer
(Houston, 7X) modified bitumen' underlayment. The underlayment is composed of SBS modified
asphalt with, a fiberglass mat, internal reinforcementand is surfaced with granules.. The
product is -supplied with a nominal thickness of 50 mils in 1.95-sq rolls with nominal
dimensions of 3-ft x 65-ft.
11 •i
VVgatherLockQ G (High Fear).is;permitted,to be.used with mechanically fastened asphalt
shingles, metal roofing, slate shingles, wood shingles and woodshakes as prescribed in
tha,FBC. Exposure on the roof deck shall be limited to a maximum 30 days.
OCR14002.6a FL9777 R9 Page.2 of 4
This evaluation report is provided for State of'Flodda product approval under Rule.61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughouttheAuration for which this report is valid.
This evaluation :report'does not express nor imply warranty,,, installation, recommended use, or other product attributes -that are not
specifically addressed herein, i
CREEK
TECHNICAL SERVIcEs, LLC
• t .
OWENS CORNING ROOFING AND ASPHALT LLC
WeatherLock® Self -Sealing Ice & Water Barilers
PRODUCT APPLICATION
Min. Roof Slope:
2:12 or in accordance in with the FBC
Application:
All underlayments shall be installed in accordance with. the FBC.
Deck substrates shall be clean, dry, and free from any irregularities and debris. All
fasteners in the deck shall be checked for protrusion and corrected prior to underlayment
application. Prior to beginning installation, the und6dayment shall be, unrolled and
allowed "to relax for a minimum of 3-5 minutes;,
The und6dayment shall be installed with the release. backer removed and pressed firmly
into place to. ensure complete contact with'the deck. The underlayment shall be. installed
with the roll length parallel to the save, starting at the eave, and with minimum 3" side
laps and minimum 6".end laps staggered min. 6-ft.from preceding course. Additionally,, if
applying WeatherLock® Specialty Tile &. Metal, end laps shall be. primed with ASTM D
41 primer or sealed with asphalt roof cement. a minimum of 3-4 inches, across,_ the width
of the lap.
A is permissible to back nail the undedayment 12-inches on -center as needed (nails shall
.beinstalled perpendicular to deck with the nail heads flush to the .top surface of the
underlayment). Additionally, WeatherLock® Specialty Tile & Metal shall be back nailed
when installed on roof slopes greater than 3:.12.,
Min. Application
40°F; Contact the manufacturer when installing at temperatures below the. minimum'
Temperature:
application temperature,
WIND RESISTANCE
The Maximum Design Pressures shown below were. calculated using a 2:1 'margin of safety, per FBC Section,1504.9.
Underiavment System No.1 — WeatherLock Specialty Tile & Metal Only
Roof Deck: Min': 15/32=inch CDX plywood; attached,to wood,supports spaced a maximum 24" o.c.
Underlayment: WeatherLock® Specialty Tile 8 'Metal: shall be applied in accordance with
manufacturer's installation instructions.jo; the fastened deck and backnailed along the
selvage with :minimum 12ga:; 1-174-inch " galvanized . ring shank roofing nails 'through
optionally primed, 32ga. x 1 ,-/S-Inc( 0 ,tiri: caps spaced, 12" oz.. The applied:
underlayment shall. be rolled with a minuppm' 15Zsteel roller immediately following
application.
Maximum Design -105 psf
.Pressure:
Technical Services, LLC of any produdt changes or
This evaluation report. does not express nor imply,%
specifically addressed herein.
FL9777-R9 Page 3 of-4
a product approval under, Rule 61 G20-3. The manufacturer shall notify CREEK
quality, assurance changes:throughout the duration for which this.report is valid.
rarranty, installation, recommended use,,orother product attributes'that are not
• i
i
- CREEK
TECHNICAL SERVICES, LLC
OWENS CORNING ROOFING AND ASPHALT LLC
Weatherl.ock®:Self-Sealing Ice &Water Barriers
GENERAL LIMITATIONS
1) This evaluation report is not use in the HVHZ.
2) Fire Classification is -not within the scope of this evaluation.
3) Installation of the evaluated product shall comply with this report, the FBC, and the. manufacturer's published
application instructions. Where discrepancies exist' between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
4) The roof deck shall be constructed:of closely fitted. plywood sheathing for new or existing construction.
5) The space under the deck area shall be properly ventilated in accordance with the'FBC requirements.
6) All side lap seams -shall be installed to shed water from the. deck.
7) The underlayment, may be used as describedin other current. FBC product approval' documents.
8) Design wind load pressures shall be determined for components -and cladding in accordance with FBC
1609.
9) The roof deck shall be designed by others in accordance with FBC requirements to resist the design wind
load pressures for components and cladding,
10) Maximum Design Pressures fora given underiayment shall meet or exceed the design wind loads
determined for-theroof assembly.
11) All products listed' in this report shall be. manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary. R. Priest, P.E. have demonstrated compliance with the, Fib Building
Code 5�' Edition (2014) as evidenced in the referenced documents submitted by the named manufacturer.
%�1111111 LU1j1
R. P. O:P
,ems•``° G E Ns� Z��,�' 201.7.04.12
No 74'021
*: 15:15:46
' � n � WMN�bfLJ.ILFM "
STATE OF 41 ` -O4 OO
�0'0 <1% �< O R �.p P N, Zachary R. Priest, P.E.
r����S Q N1. A S-:O 2 0ti OrganFloridization No:.ANE9641istration No. 021,
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services, LLC does not have, nor will it.acquire, a financial interest in any company manufacturing or distributing
products under,this evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by -any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have,, nor will acquire, a financial interest in:any company manufacturing, or distributing products
under,this evaluation.
Zachary R, Priest, P.E. does not have; nor will acquire, a financial interest,in any other entity involved in the approval process of the•
product.
END OF REPORT
4of4
This evaluation report is provided for State of Florida product approval under Rule 61,G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation; recommended Use, or other product attributes that are not
specifically addressed herein.