Loading...
HomeMy WebLinkAboutProduct Approval Roofing Underlaymentsl � +�-,� "`3 �";:� �'a!';1 � .e�hro'3' a_ y � � �rC4 �x•Y+�. +y.. �� � 4yf}� ...� ,.,�.�. �` �': --:�` _.�;' . � '• ��no,€t- .anon, �s>i�.- use o7ztsi FiCi•i�� = r�x Product Approval m USER: Public User Product Approval Menu > Product or Aonilotion Search > Application list > Application Detail m rt�;7, FL# Application Type ' Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email ,Authorized Signature 'Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category' , Subcategory Compiiance� Method FL9777-R9 Revision 2014 Approved Owens-Corning 211 ST. LUCIE COUNTY BUILDING DIVISION FOM REVIEVN D BYOO I'_ oil DATE — _ FLANS AND PERMIT MUST BE KEPT ON JOB OR NO INSPECTION WILL SE MADE One Owens. Corning Parkway Toledo,. OH 43656 (740.) 404=7829- greg-keeler@owe'nscorning.com Greg Keeler greg.ketiler@owenscorn'ing.com THESE PLANS AND ALL PROPOSED WORK ARE SUPUE CT TO ANY COr EC T IONS REQUIRED Ur FIELD INSPECTORS THAT MAY BE N110ES'SARY IN ORDER 1.0 COMPLY WITH A" AFPQQ4L4000, .g j Roofing Underlaymehts Evaluation Report from a Florida Registered Architect or a Licensed F Professional Engineer —' Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Zachary R. Priest Evaluation Report Florida License PE-74021. Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 12/31/2020. Validated By Locke Bowden Validation Checklist - Hardcopy Received i.. Certificate of Independence FL9777 R-9C0I OCR14002 6a FBC 2014 Evaluation Report Wea+hei 'Non-HVHZ .FINAL,odf Referenced Standard and Year (of Standard) Standard Year 7t�� 'I 1111 I'A�.)TE ERS ORA 1AA0H1`0ENTS A 20.09 ASTP7 OPHE RESPONSIBILITY OF THE zoos 107 CONTRACTOR OF RECORD UL'1995 U L'189 2004 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 04/12/2017 Date' Validated 04/12/2'017 Date Pending. FBC Approval 0,4/13/2017 Date.Approved 06/.13/201.7 Summ'arvof Preduets FL # Model, Number or.Name Description 9777.1 Weatherlock G Weatherproofing 'Underlayment Limits of Use Installation Instructions Approved for.,use in; HVHZ:. No 'FL9777 R9 II OCR14002 6a FBC 2014 Evaluation Renor Weatherlock Nan-HVHZ FINAL.bdf Approved, for use outside HVHZ: Yes impact Resistant:. N/A Verified 6y: Zachary R. Priest 7402-1 i. Design Pressure: N/A Created by Independent Third Party: Yes Other: See evaluation report for limits of use. ' Evaluation Reports FL9777 R9 AE OC1114002 ha. FBC 2014 i=valuailon Rep Weatherlock Non HVHZ:FINAL.pdf Created by Independent third Party Yes .9777.2 WeatherLock G (High' Tear) "Weatherproofing. Underlayment .Limits of, Use, Installation Instructions: Approved for use q HVHZ; No F49777 R9 II OCRI4002.6a FBC 201-4 Evaluation.Repo `Weatherlock Non-HVHZ FINAL Of Approved for use outside: HVHZ; Yes Impact Resistant: N/A Verified By: Zachary R: Priest PE-7402.1 Design Pressure: N/A Created by Independent Third Party.: Yes Other: See evaluationreport for limits of use. '.Evaluation Reports FL9777 R9 AE OCR140D2 ,6a FBC 2014 Evaluation Repo W/ Non-HVHZ,FINAL.pdf atheriock Created by Independent Third Party: Yes 9777.3 Weatherloak'MAT Waterproofing. Underlayment Limits of Use. ' Installation Instructions. Approved for use in HVHZ: Yes; FL9777 R9 II OCR14002 6tr FBC 2014 Evaluation Repor Weatherlock HVHZ.pdf Approved for use outside.HVHZ: No Impact Resistant:'N/A Verified By:, Zachary. R. Priest 74021 Design Pressure: N/A Created by Independent Third Party: Yes Other: See evaluation report for limits of use. Evaluation Reports F0777'R9 AEOCRI4002'6b ER-C 2014 Evaluation Repc Weatherlock HVHZ:pdf Creat d by Independent Third Party; Yes 9777.4 Weatherlock MAT,; I. Waterproofing'.Underlayment- ' L'imits of Use Installation Instructions Approved #or. use In HVHZ: No FI V77 R9IT OCR14002 5a FBC 2014 Evaluation Reoor Approved for use,outsde HVHZ: Yes Weatherlock Non-HVHZ FINAL pdf I.mpact;Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure: N/A 'Created by Independent third Party: Yes Other:•See evaluation report:for limits of use;, Evaluation Reports I1 W4 'R9.AE, OCR14002 6a FBC 2014 Evaluation Rep Weatherlock Non-HVHZ.. FINAL Ddf I Created by Independent Third: Party: Yes f 9777.5r WeatherLock.: Metal Weatherproofing Underlayment f�Limits of Use, Installation Instructions Approved for use in HVHZ: No I Approved for use outside. HVHZ; Yes FL9777' R9 II' 06R14002 6a FBC 2014 Evaluation Reoor Weatherlock Non-HVHZ FINAL.pdf Verified By: Zachary R. Priest PE-7,4021 impact Resistant: N/A Design Pressure: N/A Created by.Independent Third Party:'Yes Other: See evaluation report for limits of use. Evaluation Reports 1FL9777 R9 AE' OCR14002 6a FBC 2014 Evaluation Repo . f . Yes 7-77.6 WeatherLock Metal I W,.eatherproofing Underlayment Limits of Use Installation Instructions Approved for use in HVHZ Yes FL9777 R9 .II OCRI4002.6b_F134t 2014 Evaluation Regor Approved for use outside HVHZ:_ No Weatherlock HVHZ:adf Impact Resistant: NSA Verified By; Zachary lt; Priest PE-74021. Design Pressure: N/A Created by Independent Third Party: Yes j Other: See evaluation. report for limits of use. Evaluation Reports Third.Party: Yes. 't9777:7 Weatheryr4d kf5 ec`ialt Tile I k bp, - Meal Weatherproofing Underlayment Limits of. Use Installation Instructions -� Approved 'for use in HVHZ: No FL9777 R9 .II OCRI4002.6a•FBC 2014 Evaluation Repor f Approved for use outside_HVHZ; Yes We Eherlock..Non-WHZ JNAL.odf Impact Resistant:'N%A Verified By: Zachary R Priest Design Pressure: +0/-105' Created by Independent Third Party: Yes Other•. See evaluation report for limits of use. Evaluation Reports Party: Yes: OatK stox& Contact lls :; 2601 Blair Stone Road .Tallahassee FL- 32399.Phone: 850-4874824 The. State of. Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Prlyacv Statement c Accessibility Statement':: Rerund Statement ., Under Florida,law, email addresses are public "records. •If ydu:do not want your a -mall address released. in response to a p(iblic-records request, do not-send-ele maii;to. this entity. Instead, contact the office by phone or by tradltional;mail. If you Piave -any questions,•please contact-650.487.1395. *Pursuagt'to Secti 455.2750)i Florida Statutes, effective october 1,,Z012, licensees license&under Chapter 455, F.S. must provide the Departnei nt with an email address if the one: The emalisprovided'may be used for official communication with the.,llcen'see.,Hgweyer'email addressessare,public record. If you do not wish to supplya F'. address, please provide the Department.with,anemail-address�which can be made available to the public. To detemiine:if you are.a'Iicensee;vnder Cbaptee . ,please dic Pik . Product A , c.. pproval Aecepts; MM In, 970 . e«F `. E. Credit'Card . Safe k CREEK TECHNICAL. SERVICES, LLC. Certificate of Authorization No. 29824 17520 Edinburgh Drive Tampa, FL 33647 (813)480-3421 EVALUATION REPORT FLORIDA BUILDING CODE 5T" EDITION (2014) Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC Issued April 12, 2017 1 Owens Corning, Parkway Toledo, OH 43657 (800)438-7465 www.owenscorn ing.com Manufacturing Location: Brentwood, NH Houston, TX Quality Assurance: UL LLC (Q'UA9625) SCOPE Category: Roofing Subcategory.Underlayments Code Sections: 1504.3.1,15072.4, 1507.2.8, 1507.2.9.2, 1507.3.3, 1507::4:5, 1507.4.5.2i 1507.5.3; 1507;5.3.2, 1507.7.3, 1507:7:3.2 Properties: Physical Properties REFERENCES Ent Report No. Standard Year PRI Construction Materials Technologies (TST6049) NEI-039-02-01 ASTM D 1970 2009 PRI Construction Materials Technologies (TST6049). NEI-042-02-01REV2 ASTM D 1970 2009 PRI Construction Materials Techrologies (TST6049) NEI-045-02-01 TAS 103 1995 PRI Construction Materials Technologies (TST6049) NEI-045-02-01 ASTM G 155. 2005.a PRI Construction Materials Technologies (TST6049) NEI=053-02-01 TAS 103 1995 PRI Construction Materials Technologies (TST6049) NEI-053-02-01 ASTM G' 155 2006a PRI Construction Materials Technologies••(TST6049). , NEF093-02-02 ASTM D 1970 2009 PRI Construction Materials Technologies,(TST6049) ' OCF;213-02-01 ASTM D 1623 2009 PRI Construction Materials Technologies'(rST6049) OCF-237-02-61 UL 1897 2004 PRI Construction Materials Technologies (TST5878) OCF-252-02-01 ASTM D 4798 200.1, PRI Construction Materialste' chnologies (TST6049) OCF-252-02-01 ASTM,D 1970 2009 PRI Construction Materials Technologies (TST5878) OCF=253.02-02 ASTM D 1970 2009 PRI Constrbctlon. Materials, Technologies (TST(5049) OCF=272-02-01 TAS 103 1995 PRI Construction MaterialsTechnolagies (TST6049) OCF-296-02-02 ICC-ESAC 188" 2012 ICC-ES:AC 48 2012 PRI Construction Materials Technologies (TST6049) OCF-297-02-01.1 ASTM D 1970 2009 'Determined to be equivalent to ASTM D.226-06; Type l and it OCR14002.6a This evaluation Technical Servi This evaluation specifically add M FL9777-R9 Page 1 6f 4' rt Is provided for State otFlorida product approval. under 61G20:3.. iThe manufacturer shalt notify CREEK .LC of any product changes or quality assurance ohan'ges throughout the duration for which this report is valid.. rt. does not express nor imply warranty, installation, recommended use, or other product attributes that are not d herein. j` CREEK. TECHNICAL SERVICES, LLC, PRODUCT DESCRIPTION AND LIMITS OF USE OWENS CORNING: ROOFING AND ASPHALT LLC WeatherLock® Self -Sealing Ice & Water Barriers WeatherLock®-G WeatherLock® G, is an. ASTM D 1970 self-adhesive underlayment constructed: from SBS (Brentwood, NH) modified asphalt, a fiberglass mat reinforcement and surfaced with granules. The product is supplied in 2-sq. rolls with nominal dimensions of 3-ft x 66;7-ft: WeatherLock( G is permitted to be used with mechanically fastened asphalt shingles, wood shakes or shingles,_ and slate roofing as prescribed in the FBC. Exposure on the roof deck shali be limited to a maximum a0 days. WeatherLock® Mat WeatherLockO Mat is an ASTM D 1970 self-adhesive underlayment constructed from (Brentwood, NH or SBS modified asphalt,with a fiberglass mat reinforcement. The. product is supplied' in 1- Houston, 7X) sq. rolls with nominal dimensions of 3-ft x 33.3-ft and 2 sq.. rolls with nominal dimensions of 3-ft x 66.7-ft. WeatherLockl& Mat is permitted to be used with mechanically fastened asphalt shingles, wood shakes or shingles, and slate, roofing as prescribed in the FBC. Exposure on the roof deck shall be limited to a maximum 30 days. WeatherLock® Metal WeatherLock® Metal is an ASTM D 1970 self-adhesive underlayment constructed from (Brentwood, NH) SBS modified asphalt with a fiberglass mat reinforcement and pi astic film surface. The product is supplied in 2.0 sq. rolls with nominal dimensions of 3-ft x 66.74L WeatherLock® Metal is permitted -to be used with mechanically 'fastened asphalt shingles, metal roof panels or shingles,, wood shakes or shingles, and slate roofing as prescribed in the FBC. Exposure on the roof deck shall be limited to a maximum 90 days. WeatherLock® WeatherLock@ Specialty Tile & Metal is an ASTM D 1970 self-adhesive underlayment Specialty Tile & Metal constructed from SBS, modified: asphalt and surfaced with a non -woven polyester fabric. (Brentwood, NH) The product is supplied in 2.14 sq.:rolls,with nominal dimensions -of 3-ftx 71,3-ft. I, P VIleatherLock� Specialty Tile & Metal is permi led, to. be used with mechanically fastened asphalt shingles, clay or concrete til ��metal roo +" f,psanelsor shingles, wood shakes or shingles, and, slate roofing as prescnbed m,the-FBC'-WeatherLock® Specialty Tile & Metal is per itted to be used with adhered clay or concrete file roof using either WTM 2-Component Foam Roof Tile Adhesive AHA60 (3M Company) or TILE BONDTM Roof Tile Adhesive (The Dow Chemical Company,), Fxpos ro ck b it „, to a maximum 90 days. The maximum roof slope shall be- when used wi clay er�oacrete t s ops without battens. Tile shall be stored on battens for roof slopes greater than 6.12. Tiles shall not be stacked 'greater 10 tiles per stack, WeatherLock® G (High 1NgatherLock® G (High. Tear) is a, self-gdhere. d, ,undertayment used as an alternative,to Tear) ASTM D 226, Type I or Type II roofing felt and ASTM D 1970. self -adhering polymer (Houston, 7X) modified bitumen' underlayment. The underlayment is composed of SBS modified asphalt with, a fiberglass mat, internal reinforcementand is surfaced with granules.. The product is -supplied with a nominal thickness of 50 mils in 1.95-sq rolls with nominal dimensions of 3-ft x 65-ft. 11 •i VVgatherLockQ G (High Fear).is;permitted,to be.used with mechanically fastened asphalt shingles, metal roofing, slate shingles, wood shingles and woodshakes as prescribed in tha,FBC. Exposure on the roof deck shall be limited to a maximum 30 days. OCR14002.6a FL9777 R9 Page.2 of 4 This evaluation report is provided for State of'Flodda product approval under Rule.61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughouttheAuration for which this report is valid. This evaluation :report'does not express nor imply warranty,,, installation, recommended use, or other product attributes -that are not specifically addressed herein, i CREEK TECHNICAL SERVIcEs, LLC • t . OWENS CORNING ROOFING AND ASPHALT LLC WeatherLock® Self -Sealing Ice & Water Barilers PRODUCT APPLICATION Min. Roof Slope: 2:12 or in accordance in with the FBC Application: All underlayments shall be installed in accordance with. the FBC. Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. Prior to beginning installation, the und6dayment shall be, unrolled and allowed "to relax for a minimum of 3-5 minutes;, The und6dayment shall be installed with the release. backer removed and pressed firmly into place to. ensure complete contact with'the deck. The underlayment shall be. installed with the roll length parallel to the save, starting at the eave, and with minimum 3" side laps and minimum 6".end laps staggered min. 6-ft.from preceding course. Additionally,, if applying WeatherLock® Specialty Tile &. Metal, end laps shall be. primed with ASTM D 41 primer or sealed with asphalt roof cement. a minimum of 3-4 inches, across,_ the width of the lap. A is permissible to back nail the undedayment 12-inches on -center as needed (nails shall .beinstalled perpendicular to deck with the nail heads flush to the .top surface of the underlayment). Additionally, WeatherLock® Specialty Tile & Metal shall be back nailed when installed on roof slopes greater than 3:.12., Min. Application 40°F; Contact the manufacturer when installing at temperatures below the. minimum' Temperature: application temperature, WIND RESISTANCE The Maximum Design Pressures shown below were. calculated using a 2:1 'margin of safety, per FBC Section,1504.9. Underiavment System No.1 — WeatherLock Specialty Tile & Metal Only Roof Deck: Min': 15/32=inch CDX plywood; attached,to wood,supports spaced a maximum 24" o.c. Underlayment: WeatherLock® Specialty Tile 8 'Metal: shall be applied in accordance with manufacturer's installation instructions.jo; the fastened deck and backnailed along the selvage with :minimum 12ga:; 1-174-inch " galvanized . ring shank roofing nails 'through optionally primed, 32ga. x 1 ,-/S-Inc( 0 ,tiri: caps spaced, 12" oz.. The applied: underlayment shall. be rolled with a minuppm' 15Zsteel roller immediately following application. Maximum Design -105 psf .Pressure: Technical Services, LLC of any produdt changes or This evaluation report. does not express nor imply,% specifically addressed herein. FL9777-R9 Page 3 of-4 a product approval under, Rule 61 G20-3. The manufacturer shall notify CREEK quality, assurance changes:throughout the duration for which this.report is valid. rarranty, installation, recommended use,,orother product attributes'that are not • i i - CREEK TECHNICAL SERVICES, LLC OWENS CORNING ROOFING AND ASPHALT LLC Weatherl.ock®:Self-Sealing Ice &Water Barriers GENERAL LIMITATIONS 1) This evaluation report is not use in the HVHZ. 2) Fire Classification is -not within the scope of this evaluation. 3) Installation of the evaluated product shall comply with this report, the FBC, and the. manufacturer's published application instructions. Where discrepancies exist' between these sources, the more restrictive and FBC compliant installation detail shall prevail. 4) The roof deck shall be constructed:of closely fitted. plywood sheathing for new or existing construction. 5) The space under the deck area shall be properly ventilated in accordance with the'FBC requirements. 6) All side lap seams -shall be installed to shed water from the. deck. 7) The underlayment, may be used as describedin other current. FBC product approval' documents. 8) Design wind load pressures shall be determined for components -and cladding in accordance with FBC 1609. 9) The roof deck shall be designed by others in accordance with FBC requirements to resist the design wind load pressures for components and cladding, 10) Maximum Design Pressures fora given underiayment shall meet or exceed the design wind loads determined for-theroof assembly. 11) All products listed' in this report shall be. manufactured under a quality assurance program in compliance with Rule 61 G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary. R. Priest, P.E. have demonstrated compliance with the, Fib Building Code 5�' Edition (2014) as evidenced in the referenced documents submitted by the named manufacturer. %�1111111 LU1j1 R. P. O:P ,ems•``° G E Ns� Z��,�' 201.7.04.12 No 74'021 *: 15:15:46 ' � n � WMN�bfLJ.ILFM " STATE OF 41 ` -O4 OO �0'0 <1% �< O R �.p P N, Zachary R. Priest, P.E. r����S Q N1. A S-:O 2 0ti OrganFloridization No:.ANE9641istration No. 021, CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it.acquire, a financial interest in any company manufacturing or distributing products under,this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by -any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have,, nor will acquire, a financial interest in:any company manufacturing, or distributing products under,this evaluation. Zachary R, Priest, P.E. does not have; nor will acquire, a financial interest,in any other entity involved in the approval process of the• product. END OF REPORT 4of4 This evaluation report is provided for State of Florida product approval under Rule 61,G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation; recommended Use, or other product attributes that are not specifically addressed herein.