HomeMy WebLinkAboutFilled Density Test Coppact Soils1798 AGORA CIRCLE S.E. SUITE 5
PALM BAY, FLORIDA 32909
FIELD
MO ENGINEERING & TESTING
250 S.W. 13M AVENUE
JUN 1 3.2006 POMPANO BEACH, FLORIDA 33069
SOILS
DATE: 6/1/06 ORDER NO: 06-2889 PERMIT NOrI
CLIENT: TRIPLE H TRACTOR SERVICE
ADDRESS: 1401 ORANGE AVENUE. FORT PIERCE, FLORIDA 34950
PROJECT: PROPOSED RESIDENCE BUILDING PAD LOT 8-9
ADDRESS: BALSA AVENUE, PORT ST. LUCIE, FLORIDA
MATERIAL DESCRIPTION: BROWN SILICA SAND W/SOME CLAY & TRACES OF SHELL FRAGS
LOCATION: S.E. CORNER OF PAD
LOCATION: N.E. CORNER OF PAD
LOCATION: S.W. CORNER OF PAD
LOCATION:
LOCATION:
LOCATION:
. s ,
FIELD DENSITY METHOD A.S.T.M. D-2922
DRY DENSITY P.C.F. IN THE FIELD
105.7
106.0
106.3
% MOISTURE
9.8
9.3
9.6
% COMPACTION IN THE FIELD
95.9
96.2
96.5
% COMPACTION REQUIREMENT
95%
PROCTOR VALUE, P.C.F.
110.2
OPTIMUM MOISTURE, %
12.1
LABORATORY- NO.
P-2788
DEPTH IN INCHES
12
PROCTOR A.S.T.M D-1557 METHOD
REMARKS: S01EL NOT TESTED BELOW FOOTERS
TESTED BY: SL. Respectfully submitted,
CHECKED BY: KMg
SAM S. NAAMANI, P.E.
As a mutual protection to clients, the public and ourselves, all reports FEDERAL ENGINEERING & TESTING
are submitted as the confidential property of clients, and authorization FLORIDA REG. #39584
for publication of statements, conclusions or extracts from or regarding
our reports is reserved pending our written approval. -
A density test determines the degree of compaction of the tested layer of material only. A density does not replace a soil bearing capacity determination.