HomeMy WebLinkAboutEvaluation Report(_)0 ,t I RINIIYIERD EVALUATION REPORT Johns Manville Corporation P.O. Box 5108 Denver, CO 80217 ST. LUCTE COUNT:r BUgr1NG.DIVT>.SION REVIEWED FOR COI EEXTERIOR RESEARCH & DESIGN, LLC. RLVIE:i'ED BY Certificate of Authorization#9503 DATE I • r% 353 Christian Street PLANS ANC pF,1_?_NWr MUST BE KEPT ON JOB Oxford, CT 06478 ORNO INSPECTION WILL BE MADE. PHONE: (203) 262-9245 FAX: (203) 262-9243 Evaluation Report J9340.05.08-R3 FL1037-R6 Date of Issuance: 05/19/2008 Revision 3: 04/28/2015 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed, by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 5th Edition (2014) Florida Building Code sections noted herein. DESCRIPTION: JM Built -Up Roofing Systems LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity I ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 4, plus a 14-page Appendix. Prepared by: TiACHME�' CO D FASZENERS 0`� Of ZHE AREi CS080F RECOAp CONT� Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCAANE1983 THESE PLANS AND ALL PROPOSED WORK ARE -SUBJECT F ELD �NgPECTORS THAT REQUIRED BY MAY BE NECESSARY IN ORDER T.0 COMPLY WITH ALL APPLICAOLE CQDEB' The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 04/28/2015. This does not serve as an electronically signed document. Signed, sealed hardcoples have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. Exterior Research & Design, LLC. d/b/a Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Exterior Research & Design, LLC. d/b/a Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E, does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. r ROOFING SYSTEMS EVALUATION: 1. SCOPE: �I TRINITY I ERD Product Category: Roofing Sub -Category: Built -Up Roofing Systems Compliance Statement: JM Built -Up Roofing Systems, as produced by Johns Manville Corporation, have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. STANDARDS: Section Proper Standard Year 1504.3.1 Wind FM 4474 2004 1504.7 Impact FM 4470 1992 1507.10.2 Physical Properties ASTM D2178 2004 1507.10.2 Physical Properties ASTM D3909 1997 1507.10.2 Physical Properties ASTM D4601 2004 1523.6.2 Wind TAS 114 2011 3. REFERENCES: gattl Examination Reference Date FM Approvals (TST1867) FM 4470 3001629 09/10/1998 FM Approvals (TST1867) FM 4470 3D4A4.AM 09/28/1998 FM Approvals (TST1867) FM 4470 3000949 06/05/1998 FM Approvals (TST1867) FM 4470 3001482 08/11/1998 FM Approvals (TST1867) FM 4470 OZ8A9.AM 09/10/1998 FM Approvals (TST1867) FM 4470 3007148. 04/19/2000 FM Approvals (TST1867) FM 4470 3006346 08/15/2000 FM Approvals (TST1867) FM 4470 3009499 04/04/2001 FM Approvals (TST1867) FM 4470 3011057 08/10/2001 FM Approvals (TST1867) FM 4470 3012974 06/03/2002 FM Approvals (TST1867) FM 4470 3014090 09/05/2002 FM Approvals (TST1867) FM 4470 3011248 11/01/2002 FM Approvals (TST1867) FM 4470 3015444 07/11/2003 FM Approvals (TST1867) FM 4470/4474 3026130 04/26/2006 IRT (TST7408) TAS 114 99001.1.20.99 01/20/1999 IRT (TST7408) TAS 114 99002.1.20.99 01/20/1999 IRT (TST7408) TAS 114 99003.1.20.99 01/20/1999 IRT (TST7408) TAS 114 .99006.1.20.99 01/20/1999 IRT (TST7408) TAS 114 99007.1.20.99 01/20/1999 IRT (TST7408) TAS 114 99008.1.20.99 01/20/1999 IRT (TST7408) TAS 114 99016.1.20.99 01/20/1999 IRT (TST7408) TAS 114 99009.2.10.99 02/10/1999 IRT (TST7408) TAS 114 99010.2.10.99 02/10/1999 IRT (TST7408) TAS 114 02-026 07/26/2002 IRT (TST7408) TAS 114 02-011 02/06/2002 Miami -Dade (CER1592) Physical Properties Various NOAs Current UL LLC (QUA9625) Quality Control Service Confirmation Exp. 10/22/2016 Exterior Research and Design, U.C. Evaluation Report J9340.05.08-R3 Certificate of Authorization #9503 F1.1037-116 Revision 3: 04/28/2015 Page 2 of 4 ERD QFD ��J�N I 4. PRODUCT DESCRIPTION: This Evaluation Report covers Johns Manville Built -Up Roof Systems (BUR) installed in accordance with Johns Manville published installation instructions and the Limitations / Conditions of Use herein. The following Johns Manville products make up the subject s stems 5. y ' " '' 1ABLE1 ROLL GOODSFORJOHNSMANVILLEBUILTUPROOFSYSTEMS S Type Product Specification Type Base Sheets DynaBase NASTM3 j4897 Type[ GlasBase Plus 1 TypeII Ventsulation Felt Type II Ply Sheets PermaPly 28 ASTM D4601 Type 11 GlasPly IV ASTM D 4601 Type IV GlasPly Premier ASTM D 2178 Type VI Cap Sheets GlasKap ASTM D3909 N/A GlasKap CR ASTM D3909 N/A GlasKap Plus ASTM D5147 N/A LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity) ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in HVHZ. 5.3 Refer to a current Roofing Materials Directory for fire ratings of this product. 5.4 For steel deck installations, foam plastic insulation shall be separated from the building interior in accordance with FBC 2603.4 unless the exceptions stated in FBC 2603.4.1 and 2603.6 apply. 5.5 The roof system evaluation herein pertains to above -deck roof components. Roof decks shall be in accordance with FBC requirements to the satisfaction of the AHJ. Wind load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 5.6 For recover installations, the existing roof shall be examined in accordance with FBC 1510. 5.7 For mechanically attached insulation or membrane or strip -bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16. Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are RAS 117 and FM LPDS 1-29. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.1.5.1(a) of FM LPDS 1-29 for Zone 2/3 enhancements. 5.8 For assemblies where all components are fully adhered, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. 5.9 For mechanically attached insulation or membrane over existing roof decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with TAS 105 or ANSI/SPRI FX-1. 5.10 For bonded insulation or membrane over existing substrates in a re -roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance with ASTM E907, FM LPDS 1-52, ANSI/SPRI IA-1 or TAS 124 shall be conducted on mock-ups of the proposed new roof assembly. 5.11 For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the AHJ, as documented through field uplift testing in accordance with ASTM E907, FM LPDS 1-52 or TAS 124. 5.12 Metal edge attachment (except gutters), shall be designed and installed for wind loads in accordance with FBC Chapter 16 and tested for resistance in accordance with ANSI/SPRI ES-1 or RAS 111, except the basic wind speed shall be determined from FBC Figure 1609. Exterior Research and Design,LLC. Certificate of Authorization #9503 Evaluation Report J9340.05.08-113 FL1037-R6 Revision 3: 04/28/2015 Page 3 of 4 ` J TRINITY `ERD 5.13 All products in the roof assembly shall have quality assurance audit in accordance with the FBC and F.A.C. Rule 61G20-3. 6. INSTALLATION: 6.1 Johns Manville Built -Up Roof Systems shall be installed in accordance with Johns Manville Corporation published Installation instructions, subject to the Limitations / Conditions of Use herein. 6.2 System attachment requirements for wind load resistance are set forth in Appendix 1. MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind loads. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 CIA requirements. 9. QUALITY ASSURANCE ENTITY: UL LLC—QUA9625; (414) 248-6409; Karen.buchmann@us.ul.com - THE 14-PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT - Exterior Research and Design, I.I.C. Evaluation Report J9340.05.08-113 Certificate of Authorization #9503 FL1037-R6 Revision 3: 04/28/2015 Page 4 of 4 Table Deck Application Type Description Page 1A-1 Wood New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 3 1A-2 Wood New or Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 3 16 Wood New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Banded Top Insulation, Bonded Roof Cover 3 1C Wood New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 4 ID Wood _ New, Reroof (Tear -Off) or Recover D Prelim. Attached Insulation, Mech, Attached Base Sheet, Bonded Roof Cover 4 ' SE- Wood, =Nev4orRerodf(fear-Off) - iE. 'Non-Insulated,-Mech.Attached.BaseSheet Bonded Roof Cover• 4 Steel or Conc. New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 5 2B Steel or Conc. New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 6 2C Steel or Conc. New, Reroof (Tear -Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 6 3A Concrete New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 7 3B Concrete New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 7 4A LWIC New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover B 4B LWIC New or Reroof (Tear -Off) E Mech. Attached Base Sheet, Bonded Roof Cover 9 4C LWIC New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 9 SA-1 CWF New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 10 SA-2 CWF New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 10 513 CWF New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 10 5C CWF New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 11 SD-1 CWF New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 11 SD-2 CWF New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 11 6A-1 Gypsum Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 12 6A-2 Gypsum Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 12 6A-3 Gypsum Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 12 68 Gypsum Reroof (Tear -Off) B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 13 6C Gypsum Reroof (Tear -Off) C Mech. Attached Insulation, Bonded Roof Cover 13 6D-1 Gypsum Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 13 6D-2 Gypsum Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 13 7 Various Recover A-1 Bonded Insulation. Bonded Roof Cover 14 Exterior Research and Design, LLC. d/b/a Trinity ( ERD Evaluation Report J9340.05.O8-113 for FL1037-R6 Certificate oJAutharization N9503 Revision 3: 04/28/2015 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 1 of 14 r" i TRINITYERD The following notes apply to the systems outlined herein: 1. The roof system evaluation herein pertains to above -deck roof components. Roof decks shall be in accordance with FBC requirements to the satisfaction of the AHJ. Wind load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Unless otherwise.noted; fasteners and itress plates for Insulation attachment shall be as follows. Fastenersshalhbe of.sufflcient length fcrthe:following engagements: i Woz Deck: 1 f UltraFast Fastenersor.All Purpose�Fasteners with UltraFast Metal Plates. Minimum V.-Inch plyvipod.penetratlon or minimum 1-inch wood plank embedment. ent. Y Steel Deck: UltraFast Fasteners or All Purpose Fasteners with UltraFast Metal Plates. Minimum Y.-inch steel penetration and engage the top flute of the steel deck. > Concrete Deck: All Purpose Fasteners with UltraFast Metal Plates or Structural Concrete Fasteners with UltraFast Metal Plates (flat bottom only). Minimum 1-Inch embedment Fasteners installed with a pilot hole In accordance with the fastener manufacturer's published installation Instructions. 3. Unless otherwise noted, Insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite, gypsum -based roof board or Invinsa Roof Board that meets the CA requirements of F.A.C. Rule 61G20.3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when installed with the roof cover. 4. Unless otherwise noted, Insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer's published Instructions. Y Hot asphalt (HA): Full coverage at 25-30lbs/square i JM MBR Bonding Adhesive (MBR-BA): Continuous Y.-Inch wide ribbons, 12-inch o.c. or full coverage at 2.0 gal/square Y JM Two -Part Urethane Insulation Adhesive (UTA-2): Continuous Y-inch wide ribbons, 12-inch o.c. > 3M CR-20: Continuous 2% to 3%-inch ribbons, 12-Inch o.c. Y Note: When multiple loyers(s) of lnsulotion and/or coverbaard are installed In ribbon -applied adhesive, adhesive ribbons shall bestaggered from layer-to-loyer a distance of one-half the ribbon spacing. > Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. 5. Unless otherwise noted, all insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum Design Pressure (MDP) limitations. In no case shall these values be used to 'increase' the MDP listings in the tables; rather if MDP listing below meets or exceeds that listed for a particular system In the tables, then the thinner board listed below may be used as a drop -in for the equivalent thicker material listed In the table: > JM Two -Part Urethane Insulation Adhesive (UTA-2): MDP = -315.0 psf (Min. 0.5-inch thick) Y 3M CR-20: MDP = -117.5 psf (Min. 1.0-inch thick) 6. Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft. 7. For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are RAS 117 and FM LPDS 1-29. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.1.5.1(a) of FM LPDS 1-29 for Zone 2/3 enhancements. B. For assemblies where all components are fully adhered, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no rational analysis is permitted. 9. For mechanically attached components over existing decks, fasteners shall be tested In the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with TAS 105 or ANSI/SPRI FX-1. 10. For existing substrates in a bonded recover installation, the existing roof surface shall be examined for compatibility and bond performance with the selected adhesive, and the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the AHJ, as documented through field uplift testing In accordance with ASTM E907, FM LPDS 1-52, ANSI/SPRI IA-1 orTA5124. 11. LWIC shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWIC Is referenced, refer to current LWIC Product Approval for specific deck construction and limitations. For systems where specific LWIC Is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top -coat thickness is 2-inches. For LWIC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1. 12. Unless otherwise noted, a 1M BUR Roof Cover consists of hot asphalt applications of an optional base sheet of Glasbase, Glasbase Plus, PermaPly 28 or DynaBase followed by two or more plies of GlasPly IV or GlasPly Premier and an optional cap sheet of GlasKap, GlasKap Plus or GlasKap CR. Systems without a cap sheet shall be surfaced in accordance with 1M requirements, meeting the fire resistance requirements of FBC 2505.1. 13. 'MDP' = Maximum Design Pressure Is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads. Exterior Research and Design, LLC, d/b/a Trinity ) ERD Evaluation Report 19340.05.08-R3 for FL1037-R6 Certificate of Authorization N9503 Revision 3: 04/28/2015 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 2 of 14 r TRINITY ,ERD TABLE IA-1: WOOD DECKS— NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEMTYPEA-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System Deck Anchor Sheet Base Insulation Top Insulation MDP No. (See Note 1) Type Fasteners Attach Type Attach Type Attach Roof Cover (Psf) GlasBase, 32 ga., 1-5/8" 12" o.c. at the 4- One or more layers, any combination Min 1.5" Fesco Foam or Min. 19/32` GlasBase Pius, diameter tin caps Inch lap and 12" Min 1" ENRGY 3, JM ISO 3, Fesco Foam Dura Foam; Min Y." Retro-. JM BUR. See W-1. plywood at max. PermaPly No. 28 with 11 ga. o.c. In two equally or Dura Foam; Min X" Retro-Fit Board HA Fit Board or Dura Board; HA Note 12. -60.0 24-inch span ors eshoet tton annular ring spaced, staggered or Dura Board; Min Y." Fesco Board Min Y." Fesco Board base sheet shank nails center rows TABLE 1A-2: WOOD DECKS —NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER SYSTEM TYPEA-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER System Deck Anchor Sheet Base Insulation Top Insulation MDP No. (See Note 1) Type Fasteners Attach Type Attach Type Attach Roof Cover (Pso Min. Two plies GlasBase, 9" o.c, at the 4- One or more layers, any combination Min 1.5" Fesco Foam or plyw000dd aat t GlasBase Plus, inch lap and 12" Min 1" ENRGY 3, JM ISO 3; Min 1.5" Dura Foam; Min X" Retro- 1M BUR. See W-2. max. 24-Inch PermaPly 28 or See Note 2 o.c. In two equally Fesco Foam or Dura Foam; Min X" HA Fit Board Dura Board; HA Note 12. •52.5 span Ventsulation base spaced, staggered Retro-Fit Board or Dura Board; Min Y." Mln'/." Fesco Board Fesco sheet centerrows Fesco Board 8" o.c. at the 3- Min. 19/32" Inch lap and 8" One or more layers, any combination Min 1.5" Fesco Foam or W3' plywood at GlasPly Premier base See Note 2 o.c. in three Min 1" ENRGY 3, JM ISO 3, Fesco Foam HA Dura Foam; Min Y." Retro- HA JM BUR. See -52.5 max. 24-Inch sheet equally spaced, or Dura Foam; Min %" Retro-Fit Board Fit Board or Dura Board; Note 12. span staggered center rows or Dura Board; Min Y." Fesco Board Min Y." Fesco Board TABLE 1B: WOOD DECKS — NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER SYSTEMTYPEB: MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION LAYER, BONDED ROOF COVER System Base Insulation Layer Top Insulation Layer, MDP No. Deck (See Note 1) Roof Cover (Psf) Type Fasteners Attach Type Attach W 4 Min. 19/32" I / plywood at max. 24- Min 1" ENRGY-3 or1M ISO 3 See Note 2 2ft' Min Y.." Fesco Board; Min 1.5" Fesco Foam Dura Foam; Min Inch span Min''/." Fesco Board or DuraBoard 1 per or X" HA JM BUR. See Note 12. -45.0• Retro-fit Board or DuraBoard W-5. Min. 19/32" plywood at max. 24. Min. 1.4" ENRGY-3 or JM ISO 3, Min See Note 2 t 1 2.67ft Min F. Fesco Board; Min 1.5" Fesco Foam Dura Foam; Min %" HA JM BUR. See Note 12. 45.0• inch span pa 1.5" Fesco Foam or Dura Foam per or Retro-Fit Board or DuraBoard Exterior Research and Design, LLC. d/b/a Trinity I ERD Evaluation Report J9340.05.08-R3 for FL1037-RS Certificate of Authorization N9503 Revision 3: 04/28/2015 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 3 of 14 TRINITY 1 ERD TABLE 1C: WOOD DECKS —NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER SYSTEMTYPEC: MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER Base Insulation Layer Top Insulation Layer Roof Cover System No. Deck (See Note 1J MDP (psf) Type Attach Type Fasteners Attach Base I Ply I Cap Min. 19/32" plywood at max. (Optional) One or Min %" Fesco Board r W-6' more layers, any Loose laid Min Y," Retro-Fit Board or See Note 2 1 per 2ft JM BUR. See Note 12. -45.0• 24-Inch span combination DuraBoard Min. 19/32" plywood at max. (Optional) One or Min 1.5" Fesco Foam or Dura r W 7' more layers, any Loose laid See Note 2 1 per 2.67ft JM BUR. See Note 12. .45.01 24-inch span combination Foam TABLE ID: WOOD DECKS— NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER SYSTEM TYPED: PRELIMINARILY ATTACHED INSULATION, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER System Deck Insulation Layers) Base Sheet Roof Cover MDP (psf) Type Attach Base Fasteners Attach Ply Cap No. (See Note 1) One or more 8" o.c, at the 3-Inch lap and 8" One or more plies of GlasBase, (Optional) One ply of W-8. Min. 19/32" plywood layers, any Prelim One ply of See Note 2 o.c. in three equally spaced, GlasBase Plus, Perma Ply No. 28, GlasKap, GlasKap CR -52.5 at max. 24-Inch span combination Attach GIasPly Premier staggered center rows GIasPIy and/ar GIasPly Premier or GlasKap Plus plies (min 2 plies If no cap) C. TABLE1E: WOOD DECKS— NEW CONSTRUCTION oRRER00F(TEAR-OFF) SYSTEM TYPE E: NON -INSULATED, MECHANICALLYATTACHED BASE SHEET, BONDED ROOF COVER System Deck (See Note 1) Base Sheet Roof Cover MDP (psi) Type Fasteners Attach Ply Cap N �in. 19/32" plywood at max. GlasBase, GlasBase Plus, 32 ga., 1-5/9" diameter tin 9" o.c. at the 3-Inch lap and 18" W-9' 24-Inch span PermaPly 28 or Ventsulation caps with 11 ga. annular ring o.c. in two equally spaced, 45.0• shank nails staggered center rows One or more plies of Min. 19/32" plywood at max. Two plies GlasBase, GlasBase 32 ga., 1-5/8" diameter tin 9" o.c. at the 3-Inch lap and 12" W-10. 24-Inch span p Plus, PermaPly 28 or caps with 31 ga. annular ring o.c, in two equally spaced, GlasBase, GlasBase (Optional) One of -52.5 Ventsulation shank nails staggered center rows gg Plus, Perma Ply No. 28, GIasPly IV and/or ply GlasKap, GlasKap CR or GlasKap Plus Min. 19/32" plywood at max, 8' o.c. at the 3-Inch lap and 8" W-11. 24,Inch span GIasPly Premier base sheet See Note 2 o.c. in three equally spaced, GIasPIy Premier (min 3 -52.5 staggered center rows plies If no cap) Min. 29/32" plywood at max. GlasBase, GlasBase Plus, 32 ga., 1-5/8" diameter tin 9" o.c. at the 3-inch lap and 12" W-12. 24-Inch span PermaPly 28 or Ventsulation caps with 11 ga. annular ring o.c. in two equally spaced, -60.0 I shank nails I staggered center rows Exterior Research and Design, LLC. d/b/a Trinity ( ERD Evaluation Report 19340.05.08-R3 for FL3037-R6 Certificate of Authorization #9503 Revision 3: 04/28/2015 Prepared by: Robert Nieminen, PE-S9166 Appendix 1, Page 4 of 14