HomeMy WebLinkAboutGeneral Specifications - Domestic Tanks1 Q 1 � I o 111 S !L � J o OUTSIDE > o DIAMETER 0 0 0 LEG WIDTH General Specifications Conforms to the latest edition of the ASME code for Pressure Vessels, Section Vill, Division 1. Complies with NFPA 58. Rated at 250.psig from -20' F. to 125' F. All tanks may be evacuated to a full (14.7 psi) vacuum. Vessel Finish: Coated with epoxy red powder. ( Tanks coated with the epoxy powder must be buried). For Aboveground use, tanks maybe coated with TGIC powder. Applicable federal, state or local regulations may contain specific requirements for protective coatings and cathodic protection. The purchaser and installer are responsible for compliance with all federal, state or local regulations. n%1CDAI 1 I CAI(_`TLJ F! G nty, FL 1- - WITHDRAWAL VALVE FLOAT ' Oi10E`� LP. CAS ANODE GAUGE CONNECTION O ® `' FILLER IVALVE 1 � O 0 1 , g SERVICE / NAME MULTNALVE PLATE RELIEF VALVE FITTINGS LAYOUT UNDER DOME AGOG VESSEL DIMENSIONAL INFORMATION All vessels dimensions are approximate WATER OUTSIDE HEAD OVERALL OVERALL LEG LEG WEIGHT QUANTITY CAPACITY DIAMETER TYPE . LENGTH I HEIGHT I -'WIDTH SPACING FULL PER LOAD STACK 120 wg. 454.2 L - 24" 609.6 mm Ellip 5'- 5 13/16" 1671.3mm 3' - 0." 911.4 mm 16 1/8" 257..2 mm 31.- 0" 9.14.4 mm 245 lbs. 111.1 kg. 96 12 250 wg. 31.5" Hem! . 7' - 2 1/2 , 3' - 7 - •1/2" 12 3/4" 3`- 6" 472.Ibs: - 63 9 946.3 L 800.1 mm 2197.1 min. 1104.9 mm 323.9 mm 1066.8 mm 214.1 kg: 320 wg. .31.5. Hemi 8' -11 3/4" 3' - 7 �1/2' 12 3/4" 4'- 0 1/4" 588 lbs. .45 9 1211.2 L 800.1 r 2736.9 mm 11.04.9 mrri 323.9 mm 1225.6 mm 266.7 kg. 5.00 wg. 37.42" Hemi 9' -10" 4'- 1 7/16° 15" 5' - 0" 871 lbs. 30 6 1892.5 L 950.5 mm 2997.2 mm 1255.7 mm 381.0 mm 1524.0 mm 395.1 kg. 1000 wg. 40.96" Hemi 15' -1 113/16" 4'- 4 5116" 16 1/4". 9' - 0" 1729 lbs. 15 5 3785.0 L 1040.4 mm 4846.6 mm '1344.6 mm 412.8 mm 2743.2 mm 784.3 kg Rev: Jan. 27, 2016 STORAGE TANK IS ADEQUATrL:r' ANCHORED TO PREVENT FLOATATION, COLLAPSE OR LATERAL MOVEMENT DURING THE BASE FLOOD EVENT. ALL WORK SHALL BE IN ACCORDANCE WITH NFPA 54-58, NATIONAL FUEL GAS CODE AND FLORIDA FUEL GAS CODE 2014. TANKS INSTALLED IN TRAFFIC AREAS SHALL BE PROTECTED WITH GALV. STEEL SCHED. 80 PIPE BOLLARDS (4" 0) 6' LONG X 3' BURY DEPTH WITH CAP @ 3' O.C. PROPANE TANK BUOYANCY MAX BUOYANCY = pr*g*Vta* = 1.94 slug/ft3 * 32.2 ft/S2 * 66.84 ft' = 4176 LBS NET BUOYANCY = MAX BUOYANCY — WEIGHT OF EMPTY TANK = 4176 LBS — 871 LBS = 3305 LBS FORCE ON r CABLE = 3305 / 2 = 1653 LBS TENSILE STRENGTH OF r CABLE = 7000 LBS FORCE ON AUGER ANCHOR = 1653 / 2 = 827 LBS MIN. PULL—OUT RESISTANCE OF AUGER ANCHOR = 1360 LBS St. Lucie Cola,',, r 7x19 GALV. AIRCRAFT CABLE 2 TOTAL (IN POLY. SLEEVE) AUGER ANCHOR, 48" LONG W/ 6"0 HELIX 4 TOTAL SIDE ELEVATION SCALE I/'f' - 1'-0" GRASS (MAX COVER)I LP TANK i �— EXCAVATION SIZE. I VL x 4'W x 4.5'D 9LB. ANODE BAG " 7x19 GALV. AIRCRAFT CABLE STRAPPING BOLT AUGER ANCHOR, 48" LONG W/ 6"0 HELIX FRONT ELEVATION SCALE 1/4' = 1'-O" Ferrellgas 3232 SE Dixie Hwy. Stuart, FL 34997 z O 0 0 c� O m U E� a ISSUE DATE: DRAWN: EJS APPROVED: EJS DRAWING NUMBER T—l_ LP500 Tarantid INDUSTRIES, INC e�Tu7ir�T-: First Stage Regulators, High Pressure Domestic Provides accurate first stage regulation intwo-stage bulk tank systems. Reduces tank pressure toanintermediate pressure of5to10p5|G.Also used ,osupply high pressure burners for applications like industrial furnaces or boilers. Domestic LP -gas installations, also incorporated in multiple cylinder installations. sm PART NUMBER INLET 1CONNECTION OUTLET CONNECTION ORIFICE SIZE FACTORY DELIVERED PRESSURE INTEGRAL ADJUSTMENT RANGE RELIEF VALVE INCLUDED VAPOR CAPACITY BTU/HR. PROPANE ^Maximumflow based oninlet pressure 20mmhigher than the regulator setting and mmvery,pressur:c0% lower than the setting. Second Stage Regulators Low Pressure, Domestic Designed toreduce first stage pressure of5toZOP5|Gdowntoburnerpressune, normally 11"WC. Ideal for medium commercial installations, multiple cylinder installations and normal domestic loads. BackmmmmtDesigo Mounts directly to house line piping. Eliminates need for union joints and elbows and LV4403B LV5503B mounting brackets. Quick and easy to install. INLET OUTLET ORIFICE FACTORY DELIVERED ADJUSTMENT VENT VAPOR CAPACITY PARTNUMBER CONNECTION � CONNECTION SIZE I PRESSURE � RANGE I POSITION � BTU/HR. PROPANE rd Backmount Design Sidemount Design Especially developed for drying barns in the tobacco industry. The[V5503G4 regulator will supply a steady and constant flow of fuel to as many as 12 to 20 burners throughout the barn. uasoaow 6\ PART NUMBER INLET CONNECTION OUTLET CONNECTION ORIFICE SIZE FACTORY DELIVERED PRESSURE ADJUSTMENT RANGE VENT POSITION VAPOR CAPACITY BTU/ HR,PROPANE *Maximum flow is based on 15 PSIG inlet and 13" WC delivery pressure. � � LIQUEFIED PETROLEUM GAS COM tabj-6 15.1(6) Polyeth)4ene Plastic Pipe . Sizing Between Fmt-Stage'aAd,Se-c-*d-SPg6 Regulators: Nominal OuWde Diameter (1PS) Gas: Uniiiluti Wet Pressure: Pressure Drop;. l Q PA Plastic PiP6 -1/2-ift. 314 in, I in. 1/4 M'. IM in.. *' '2-iff. leiiffi SDR9.33 Spkllff' SDR11-i00 Mi lbo60: SR-11-00 8 R11-00 (ft) (.0.660) (0.860) : (1 077) ".(1.:554) (1-943) 30. 214& 420,2 7744. '20260 36402 40 1835 3673 6628. 17940 31155 50 1626: 3256' .:5874 10176 15368 27612 ,60 I473 2950 5822 922:0 .18924 25019 70 1355' 2714 4896- 848�3. 1281.0 '23611 80 1261. 2.5.25' -.4555 11918, Z1413 90 lin 4274 11182 20091 160 1117 2238, 4037 6994 10 562 125 990 1983 35.78 6199, 9361 1115820 160 897 17.97 3242. 5.616 8482 15240 175 826 1653 29M 5167 7803 14020 200 778 15-39 2775 4807 7259 1360 22. 72 1 1443 266 4�10 6 'k-i 12238 256 681 .1303 2459 -4260 6434 11560 -2.75 646. 1294 2336 4646 6111 10979 300 61J 1235 2228 3860 5830 10474 350 567 1136 2050 3551 5363 460 528 100 1907 3304 4989 8965 450 495 992 1789 3100 -4681 8411 560. 468 937 100 2928 4422 7945 600. 424 849 1531 .2653 . 00 . 7 Z!'jqq 700 390 781 1409 2441 3685 :6623 '80 0 363 726 1311 2271 3429 szGl '900 340 682 MO 2131 3217 1-606 322 .644 1162 2012 SOO .5461 1500 00 258 517 933 1616- 2441 4385 9000 221 443 798 pp 2089 3.753 WS-jrn pipe:size. SDR. Standard dimension ratio. Notes: (1).Capacities are in 1060 Btu/hr.. (2)'Dimensionsln parentheses.' inside diameter. 2011 Edition /7 i.: AUG 2 2 2i)lill PER,",A ITT; t%! St. LU-Cie a 0 0 :Qtnt�- &H-1 8 limit"' 'b. W, Wm (nN ca a Ol w C. (n.: CO CO KI co co to (71 'q R q 91RA tv lTtIIE 4D tA it Ld fA w A, tq - Sig w, co: 1pg _j tRtd tC-4. w :"'R;_8- W!A'Dl tp ScEt. Vt Ln M al .4'CO IB v al ..W tp t" O co iD Wpl. td w tA Ls co 156, to jo:. po 'co A (A.R Ot -4 5 toma �D: C) 0 -4 co t to to to .4 .:1- 2 o . _2:;� co, �4 " 0 co C.0 0 R 9 0 lo Z� 8) Ck d. CY L4 A D:,A. W A lb.. to tA Of p-4. C�' co,to Cl 8.z5:Z4:F! 'co 'z "g* 9 -cl lc�-> r, -.9, 0 8:-o (Dwz IN