Loading...
HomeMy WebLinkAboutEvaluation Report1 � CREEK TECHNICAL SERVICES, LLC Certificate of Authorization No. 29824 17520 Edinburgh Dr Tampa, FL 33647 (813) 480-3421 EVALUATION REPORT 2014 FLORIDA BUILDING CODE Manufacturer: MID -STATES ASPHALT AND CANT STRIP, INC. Issued March 31, 2015 1637 51 s` Street Tuscaloosa, AL 35401 (800) 489-2391 http://vmw.midstatesasphalt.com AW ;gj,_, Manufacturing Plants: Nashik, India PER,';f, Quality Assurance: UL LLC (QUA9625) St. Lucie C;cu:;ti• i=;- SCOPE Category: Roofing Subcategory: Underlayments Code Sections: 1507.2.3, 1507.3.3, 1507.5.3, 1507.7.3, 1507.8.3, 1507.9.3 Properties: Physical properties REFERENCES iu& Report No. Standard Year PRI Construction Materials Technologies (TST6049) RTX-002-02-01 ICC-ES AC 188 2012 PRODUCT DESCRIPTION AND APPLICATION MSA QUIK-FELT MSA QUIK-FELT is a woven polypropylene mechanically attached underlayment for use in steep slope roofing as an alternative to ASTM D 226, Type I and Type II. Deck Type: The roof deck shall be constructed of.closely fitted plywood sheathing for new or existing construction. Plywood deck shall be installed in accordance with FBC requirements. Roof decks shall have no more than 1/8" gap at abutting joints. Min. slope: 2:12. For slopes less than 4:12, the underlayment must be half -lapped a full 24" over the underlying course. Attachment method: Underlayment shall be attached in accordance with the FBC requirements. At minimum, mechanically fastened with minimum 1" diameter plastic cap naps with min. 1" shank placed 12" o.c. at the side laps and 2" from the from edge of the sheet and 24" o.c along the along the center lines printed on the sheet. The side laps shall be a minimum 4" wide and minimum 12" wide at the end laps. End laps shall be fastened 12" o.c, along the lap and 2" from the end of the top layer. The underlayment is installed starting at the eave, with the length of the roll parallel to the eave with the printed side facing up. All side laps shall be installed to shed water from the deck. Allowable roof coverings: Asphalt shingles, wood shakes and shingles, slate shingles, metal roof panels and shingles MSA14001.1 FL17188-R1 Page 1 of 3 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. i CREEK TECHNICAL SERVICES, LLC LIMITATIONS MID -STATES ASPHALT AND CANT STRIP, INC. MSA QUIK-FELT Code Approved Deck Drip'Edge At Rake Synthetic U Applied Over �� � nderlayment Underlayment r \ 6 r! \ ,art ��xr+ x ° .+ �r e 2" From Edge kt i�a%F � ,F5✓z-f'�s``$>s r1 p,��."'��,- f "��rBY � .� _ > „i� y Y� .f ` y,. Edge At Eaves Applied Directly To Deck 4" Top Lap:: 12" End Lap Recomnended Recommended Figure 1. Installation Detail for MSA QUIK-FELT 1) This evaluation report is not use in the HVHZ. 2) Fire Classification is not within the scope of this evaluation. 3) Wind uplift resistance in not within scope of this evaluation. 4) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. 6) Unless otherwise stated, the minimum roof slope shall be in accordance with FBC requirements. 7) All underlayments shall be installed with the roll length parallel to the eave, starting at the eave, and lapped in success courses installed up the deck in a manner that effectively sheds water from the deck. End laps shall be staggered between courses in accordance with the manufacturer's application instructions. 8) The underlayment may be used as described in other current FBC product approval documents. 9) Roof coverings shall not be adhered directly to the underlayment. Roof coverings shall be mechanically fastened through the underayment to the roof deck. 10) The underlayment shall be exposed on the roof deck for a maximum 30 days unless otherwise stated. 11) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. MSA14001.1 FL17188-R1 Page 2 of 3 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. � 1 GREED TECHNICAL SERVICES, LLC COMPLIANCE STATEMENT MID -STATES ASPHALT AND CANT STRIP, INC. MSA QUIK-FELT The products evaluated by Zachary R. Priest, P.E. have demonstrated compliance with the 2014 Florida Building Code as evidenced in the referenced documents submitted by the named manufacturer. o�i G�PRY R..pE Ns Ri`��i No 74021 .� '. STATE OF •���0,�...,o� O R �\�,�� F CERTIFICATION OF INDEPENDENCE 2015.03.31 (- 06:49:40 04'00' Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641 CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. END OF REPORT MSA14001.1 FL17188-R1 Page 3 of 3 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.