EVALUATION REPORT 2014 FLORIDA BUILDING CODE
Manufacturer:
MID -STATES ASPHALT AND CANT STRIP, INC.
Issued March 31, 2015
1637 51 s` Street
Tuscaloosa, AL 35401
(800) 489-2391
http://vmw.midstatesasphalt.com
AW ;gj,_,
Manufacturing Plants:
Nashik, India
PER,';f,
Quality Assurance:
UL LLC (QUA9625)
St. Lucie C;cu:;ti• i=;-
SCOPE
Category:
Roofing
Subcategory:
Underlayments
Code Sections:
1507.2.3, 1507.3.3, 1507.5.3, 1507.7.3, 1507.8.3, 1507.9.3
Properties:
Physical properties
REFERENCES
iu&
Report No. Standard
Year
PRI Construction Materials Technologies (TST6049) RTX-002-02-01 ICC-ES AC
188 2012
PRODUCT DESCRIPTION AND APPLICATION
MSA QUIK-FELT MSA QUIK-FELT is a woven polypropylene mechanically attached underlayment for use
in steep slope roofing as an alternative to ASTM D 226, Type I and Type II.
Deck Type:
The roof deck shall be constructed of.closely fitted
plywood sheathing for new or existing construction.
Plywood deck shall be installed in accordance with
FBC requirements. Roof decks shall have no more
than 1/8" gap at abutting joints.
Min. slope:
2:12. For slopes less than 4:12, the underlayment
must be half -lapped a full 24" over the underlying
course.
Attachment method:
Underlayment shall be attached in accordance with
the FBC requirements. At minimum, mechanically
fastened with minimum 1" diameter plastic cap naps
with min. 1" shank placed 12" o.c. at the side laps
and 2" from the from edge of the sheet and 24" o.c
along the along the center lines printed on the sheet.
The side laps shall be a minimum 4" wide and
minimum 12" wide at the end laps. End laps shall be
fastened 12" o.c, along the lap and 2" from the end
of the top layer. The underlayment is installed
starting at the eave, with the length of the roll parallel
to the eave with the printed side facing up. All side
laps shall be installed to shed water from the deck.
Allowable roof coverings:
Asphalt shingles, wood shakes and shingles, slate
shingles, metal roof panels and shingles
MSA14001.1 FL17188-R1 Page 1 of 3
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
i
CREEK
TECHNICAL SERVICES, LLC
LIMITATIONS
MID -STATES ASPHALT AND CANT STRIP, INC.
MSA QUIK-FELT
Code Approved
Deck
Drip'Edge At Rake Synthetic U Applied Over �� � nderlayment
Underlayment r
\ 6 r!
\
,art ��xr+ x ° .+ �r e
2" From Edge
kt i�a%F � ,F5✓z-f'�s``$>s r1 p,��."'��,- f "��rBY � .� _ > „i� y Y�
.f `
y,.
Edge At Eaves
Applied Directly
To Deck
4" Top Lap:: 12" End Lap
Recomnended Recommended
Figure 1. Installation Detail for MSA QUIK-FELT
1) This evaluation report is not use in the HVHZ.
2) Fire Classification is not within the scope of this evaluation.
3) Wind uplift resistance in not within scope of this evaluation.
4) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck
shall be checked for protrusion and corrected prior to underlayment application.
6) Unless otherwise stated, the minimum roof slope shall be in accordance with FBC requirements.
7) All underlayments shall be installed with the roll length parallel to the eave, starting at the eave, and lapped
in success courses installed up the deck in a manner that effectively sheds water from the deck. End laps
shall be staggered between courses in accordance with the manufacturer's application instructions.
8) The underlayment may be used as described in other current FBC product approval documents.
9) Roof coverings shall not be adhered directly to the underlayment. Roof coverings shall be mechanically
fastened through the underayment to the roof deck.
10) The underlayment shall be exposed on the roof deck for a maximum 30 days unless otherwise stated.
11) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
MSA14001.1 FL17188-R1 Page 2 of 3
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
� 1
GREED
TECHNICAL SERVICES, LLC
COMPLIANCE STATEMENT
MID -STATES ASPHALT AND CANT STRIP, INC.
MSA QUIK-FELT
The products evaluated by Zachary R. Priest, P.E. have demonstrated compliance with the 2014 Florida Building
Code as evidenced in the referenced documents submitted by the named manufacturer.
o�i
G�PRY R..pE Ns
Ri`��i
No 74021
.� '. STATE OF
•���0,�...,o� O R �\�,��
F
CERTIFICATION OF INDEPENDENCE
2015.03.31
(- 06:49:40
04'00'
Zachary R. Priest, P.E.
Florida Registration No. 74021
Organization No. ANE9641
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
END OF REPORT