Loading...
HomeMy WebLinkAboutEvaluation Report Of Metal Saleso, EVALUATION REPORT OF METAL SALES MANUFACTURING CORPORATION _ '26 GA. 5V-CRIMP PANEL' R DE f FE V. AUG ? 120117 PE[i.M[171NG FLORIDA BUILDING CODE 5TH EDITION (2014) St. Lucie COUnty, i=L FLORIDA PRODUCT APPROVAL FL 14645.3-R2 ROOFING THESE PLANS AND ALL PROPOSED WORK METAL ROOFING ARE 8BIFCT 10 ANY r"o'l- EGTIONS RFOUIRED �Y HELD INGIWxCTQCM THAT MAY CAE NIcGEaS1 N IN 0,90F,R TO CONIM WITH AWL A!'PLICIOU, 00Q.01 =' Prepared For: Metal Sales Manufacturing Corporation 545 South 3`1 Street, Suite 200 Louisville, KY 40202 Telephone: (502) 855-4300 Fax: (502) 855-4290 CONCEALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBILITY OF THE CONTRACTOR OF !RECORD Prepared By: Bala Sockalingam, Ph.D., P.E. Florida Professional Engineer #62240 1216 N Lansing Ave., Suite C Tulsa, OK 74106 j �' dq/ Z Telephone: (918) 492-5992 ST. LUCIE COUNTY FAX: (866) 366-1543 BUILDING GDd�®ON REVFOR OOPldPL ,gOE REVIEWED BY DATE ��'—� — 7 PLANS AND PERMIT MUST BE KEPT ON JOB OR This report consists of NO INSPECTION WILL Be MADE Evaluation Report (3 Pages including cover) Installation Details (1 Page) Report No. C2010-3 Date: 3.27.15 SOCKgt/,i�s��i No 62240 p �-0• •Cc • STATE OF 4Uo 0 ,e e 3,3c F,1 L G .lo FL 14645.3-R2 C2010-3 3.27.15 Page 2 of 3 Manufacturer: Metal Sales Manufacturing Corporation Product Name: 5V-Crimp Panel Description: 24" wide coverage with (5) 1/2" high ribs Materials: Min. 26 ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or Galvalume coated steel (ASTM A792) or painted steel (ASTM A755). Deck Description: Min. 19/32" thick plywood for new and existing constructions. Designed and installed as per FBC 2014. Deck Attachment: 8d x 2.5" long ring shank nails or #8 x 2" long wood screws @ 6" o.c. (Minimum) in the plywood field and @ 4" o.c. at edges New Underlayment: Minimum underlayment as per FBC 2014 Section 1507.4.5.1. Required for new construction and optional for reroofing construction. Existing Underlayment: One layer of asphalt shingles over one layer of #30 felt. For reroofing (Optional) construction only. Slope: 1/2:12 or greater in accordance with FBC 2014 Section 1507.4.2 Design Uplift Pressure 4�1� 6psfa@=taste spacing of 36":o cyDN� ', (Factor of Safety = 2) fastener'spacmgof 16" o.c. Zc��� Z_=. 196.75 psf @ fastener spacing of 8" o.c. Fastener Pattern: Type: #9-16 or #10-14 hex head wood screws with sealed washer. Fastener shall be of sufficient length to penetrate through the deck a minimum of 3/8". At panel ends @ 6" o.c. across panel width At intermediate @ 12" o.c. across panel width Test Standards: Roof assembly tested in accordance k5F'WQ2 - 3 PStaYlnd Requirements for Metal Roofing Systems'. Code Compliance: The product described herein has demonstrated compliance with FBC 2014 Section 1507.4 Product Limitations: Design wind loads shall be determined for each project in accordance with FBC 2014 Section 1609 or ASCE 7-10 using allowable stress design. The maximum support spacing listed herein shall not be exceeded. This evaluation report is not applicable in High Velocity Hurricane Zone. Fire classification is not within scope of this Evaluation Report. Refer to FBC 2014 Section 1505 and current FL 14645.3-R2 C2010-3 3.27.15 Page 3 of 3 approved roofing materials directory or ASTM E108/UL790 report from an accredited laboratory for fire ratings of this product. Supporting Documents: TAS 125 Test Reports Farabaugh Engineering and Testing Inc Project No. T181-05, Reporting Date 7/21/05 (Tests #1 & 2) Project No. T240-09, Reporting Date 9/22/09 Architectural Testing, Inc. — West Palm Beach, FL (Formerly Hurricane Test Laboratory, LLC) Project No. 0103-0712-09, Reporting Date 9/l/09 EXISTING SHINGLES (OPTIONAL) crr M=All I NEW UNDERLAYMENT TRUSS AT MAX. 24" O.C. TYPICAL PANEL INSTALLATION X-SECTION #9-16 OR #10-14 WOODSCREWS NEW UNDERLAYMENT WITH SELF SEALING WASHER AT (REQUIRED ONLY FOR MAXIMUM SPACING OF 36" O.C. NEW CONSTRUCTION) EXISTING SHINGLES MIN CRIMP MIN 26 GA. (OPTIONAL) EXISTING UNDERLAYMENT-� PLYWOOD (OPTIONAL) DETAIL 1 19/32" THICK (MIN.) #9-16 OR #10-14 WOODSCREWS NEW UNDERLAYMENT WITH SELF SEALING WASHER AT (REQUIRED ONLY FOR MAXIMUM SPACING OF 36" O.C. NEW CONSTRUCTION) EXISTING SHINGLES 5V-CRIMP (OPTIONAL) 4 /- MIN 26 GA. EXISTING UNDERLAYMENT (OPTIONAL) DETAIL 2 PLYWOOD 19/32" THICK (MIN.) 5V—CRIMP ALLOWABLE UPLIFT PRESSURE FASTENER SPACING (IN) PRESSURE (PSF) 36 41.6 16 74.8 8 196.75 GENERAL NOTES: 1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE (FBC). 2. ROOF PANELS SHALL BE MIN. 26 GA. (t = 0.0169"). EFFECTIVE COVERING WIDTH OF PANEL = 24". 3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE AS SPECIFIED ON THIS DRAWING. 4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS ARE GREATER THAN THE ALLOWABLE WIND LOADS SPECIFIED ON THIS DRAWING. 5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA BUILDING CODE, IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM REQUIREMENTS OF THIS DRAWING & THE CODE, THE CODE SHALL CONTROL. 6. RAFTERS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS. a 0 U 2 to a mN0 Na0 - M W V1Y I Z�zg o ul 2 �J00 jN 0 o0 Lo nt m N TI OF