HomeMy WebLinkAboutapproved 8. EnergyCalcsFORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:FY SPEC 792 VERONA 2 MODEL Address type:Street Address
Building Type:Bedrooms:Lot #:User 4 ---
Owner:Conditioned Area:Block/SubDivision:2069 ---
Total Stories:PlatBook:1 ---
Builder Name:Worst Case:Street:SYNERGY HOMES, LLC Yes 2637 DYER RD.
Permit Office:Rotate Angle:County:ST. LUCIE COUNTY 180 St. Lucie
Jurisdiction:Cross Ventilation:City, State, Zip:6611000 No PORT ST. LUCIE,
Family Type:Whole House Fan: Detached No F L ,
New/Existing:Terrain: New (From Plans)Suburban
Year Construct:Shielding: Suburban
Comment:
CLIMATE
Design Design Temp Int Design Temp Heating Design Daily temp
Location Tmy Site 97.5%2.5%Winter Summer Degree Days Moisture Range
___ FL, Fort Pierce FL_VERO_BEACH_MUNICIPA 39 90 70 75 299 62 Low
BLOCKS
Number Name Area Volume
___ 1 Entire House 2069 19775
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms Finished Cooled Heated
___ 1 MASTER BEDROOM 275 2475 No 2 1 Yes Yes Yes
___ 2 WIC 45 360 No 0 Yes Yes Yes
___ 3 M BATH 117 936 No 0 Yes Yes Yes
___ 4 DINING 156 1872 No 0 Yes Yes Yes
___ 5 KITCHEN 258 3096 Yes 0 No Yes Yes
___ 6 GREAT ROOM 323 3876 No 0 Yes Yes Yes
___ 7 UTILITY 64 512 No 0 Yes Yes Yes
___ 8 FOYER 55 440 No 0 Yes Yes Yes
___ 9 BEDROOM 2 180 1440 No 0 1 Yes Yes Yes
___ 10 BEDROOM 3 163 1304 No 0 1 Yes Yes Yes
___ 11 BATH 2 60 480 No 0 Yes Yes Yes
___ 12 BEDROOM 4 232 1856 No 0 1 Yes Yes Yes
___ 13 HALL 24 192 No 0 No Yes Yes
___ 14 CABANA 54 432 No 0 0 Yes Yes Yes
___ 15 WIC 4 63 504 No 0 0 Yes Yes Yes
FLOORS (Total Exposed Area = 2069 sq.ft.)
#Floor Type Space Exposed Perim Perimeter R-Value Area U-Factor Joist R-Value Tile Wood Carpet
___ 1 Slab-On-Grade Edge Ins MASTER BEDROOM 30 0 275 ft 0.473 ---0.00 1.00 0.00
___ 2 Slab-On-Grade Edge Ins WIC 9 0 45 ft 0.473 ---0.00 1.00 0.00
___ 3 Slab-On-Grade Edge Ins M BATH 9 0 117 ft 0.473 ---0.00 1.00 0.00
___ 4 Slab-On-Grade Edge Ins DINING 24 0 156 ft 0.473 ---0.00 1.00 0.00
___ 5 Slab-On-Grade Edge Ins KITCHEN 1 0 258 ft 0.473 ---0.00 1.00 0.00
___ 6 Slab-On-Grade Edge Ins GREAT ROOM 17 0 323 ft 0.473 ---0.00 1.00 0.00
___ 7 Slab-On-Grade Edge Ins UTILITY 7 0 64 ft 0.473 ---0.00 1.00 0.00
___ 8 Slab-On-Grade Edge Ins FOYER 5 0 55 ft 0.473 ---0.00 1.00 0.00
___ 9 Slab-On-Grade Edge Ins BEDROOM 2 16 0 180 ft 0.473 ---0.00 1.00 0.00
___ 10 Slab-On-Grade Edge Ins BEDROOM 3 26 0 163 ft 0.473 ---0.00 1.00 0.00
___ 11 Slab-On-Grade Edge Ins BATH 2 6 0 60 ft 0.473 ---0.00 1.00 0.00
1/12/2022 9:37:29 AM Page 2EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
FLOORS(Continued)
#Floor Type Space Exposed Perim Perimeter R-Value Area U-Factor Joist R-Value Tile Wood Carpet
___ 12 Slab-On-Grade Edge Ins BEDROOM 4 28 0 232 ft 0.473 ---0.00 1.00 0.00
___ 13 Slab-On-Grade Edge Ins HALL 1 0 24 ft 0.473 ---0.00 1.00 0.00
___ 14 Slab-On-Grade Edge Ins CABANA 25 0 54 ft 0.304 ---0.00 0.00 1.00
___ 15 Slab-On-Grade Edge Ins WIC 4 30 0 63 ft 0.304 ---0.00 0.00 1.00
ROOF
Roof Gable Roof SolarRad SA Emitt Emitt Deck Pitch
#Type Materials Area Area Color Absor.Barr Tested Tested Insul.(deg)
___ 1 Hip Composition shingles 2241 ft²0 ft²Light N 0.5 No 0.6 No 20 22.62
ATTIC
#Type Ventilation Vent Ratio (1 in)Area RBS IRCC
___ 1 Full attic Unvented 0 2069 ft²N N
CEILING (Total Exposed Area = 2200 sq.ft.)
#Ceiling Type Space R-Value Ins. Type Area U-Factor Framing Frac.Truss Type
___ 1 Under Attic(Unvented)MASTER BEDROOM 30.0 Blown 275.0ft²0.034 0.10 Wood
___ 2 Under Attic(Unvented)WIC 30.0 Blown 45.0ft²0.034 0.10 Wood
___ 3 Under Attic(Unvented)M BATH 30.0 Blown 117.0ft²0.034 0.10 Wood
___ 4 Under Attic(Unvented)DINING 30.0 Blown 156.0ft²0.034 0.10 Wood
___ 5 Under Attic(Unvented)KITCHEN 30.0 Blown 42.0ft²0.034 0.10 Wood
___ 6 Under Attic(Unvented)KITCHEN 30.0 Blown 270.0ft²0.034 0.00 Wood
___ 7 Under Attic(Unvented)GREAT ROOM 30.0 Blown 17.0ft²0.034 0.10 Wood
___ 8 Under Attic(Unvented)GREAT ROOM 30.0 Blown 383.0ft²0.034 0.00 Wood
___ 9 Under Attic(Unvented)UTILITY 30.0 Blown 64.0ft²0.034 0.10 Wood
___ 10 Under Attic(Unvented)FOYER 30.0 Blown 55.0ft²0.034 0.10 Wood
___ 11 Under Attic(Unvented)BEDROOM 2 30.0 Blown 180.0ft²0.034 0.10 Wood
___ 12 Under Attic(Unvented)BEDROOM 3 30.0 Blown 163.0ft²0.034 0.10 Wood
___ 13 Under Attic(Unvented)BATH 2 30.0 Blown 60.0ft²0.034 0.10 Wood
___ 14 Under Attic(Unvented)BEDROOM 4 30.0 Blown 232.0ft²0.034 0.10 Wood
___ 15 Under Attic(Unvented)HALL 30.0 Blown 24.0ft²0.034 0.10 Wood
___ 16 Under Attic(Unvented)CABANA 30.0 Blown 54.0ft²0.023 0.11 Wood
___ 17 Under Attic(Unvented)WIC 4 30.0 Blown 63.0ft²0.023 0.11 Wood
WALLS (Total Exposed Area = 1967 sq.ft.)
Note: First wall orientation below is as entered. Actual orientation is modified by the rotate angle (180 degrees) as shown in the "Project" section on page 1.
Adjacent Cavity Width Height Area U-Sheath Frm.Solar Below
#Ornt To Wall Type Space R-Value Ft In Ft In sq.ft.Factor R-Value Frac.Absor.Grade
___ 1 S=>N Exterior Conc. Blk - Int Ins MASTER BEDROOM 4.1 17.0 0 9.0 0 153.0 0.149 0 0 0.20 0 %
___ 2 W=>E Exterior Conc. Blk - Int Ins MASTER BEDROOM 4.1 13.0 0 9.0 0 117.0 0.149 0 0 0.20 0 %
___ 3 S=>N Exterior Conc. Blk - Int Ins WIC 4.1 9.0 0 8.0 0 72.0 0.149 0 0 0.20 0 %
___ 4 S=>N Exterior Conc. Blk - Int Ins M BATH 4.1 9.0 0 8.0 0 72.0 0.149 0 0 0.20 0 %
___ 5 N=>S Exterior Conc. Blk - Int Ins DINING 4.1 12.0 0 9.0 0 108.0 0.149 0 0 0.20 0 %
___ 6 W=>E Exterior Conc. Blk - Int Ins DINING 4.1 12.0 0 9.0 0 108.0 0.149 0 0 0.20 0 %
___ 7 W=>E Exterior Conc. Blk - Int Ins GREAT ROOM 4.1 13.0 7 11.0 3 152.8 0.149 0 0 0.20 0 %
___ 8 E=>W Exterior Conc. Blk - Int Ins UTILITY 4.1 6.0 0 8.0 0 48.0 0.149 0 0 0.20 0 %
___ 9 S=>N Exterior Conc. Blk - Int Ins UTILITY 4.1 1.0 0 8.0 0 8.0 0.149 0 0 0.20 0 %
___ 10 E=>W Exterior Conc. Blk - Int Ins FOYER 4.1 5.0 0 8.0 0 40.0 0.149 0 0 0.20 0 %
___ 11 E=>W Exterior Conc. Blk - Int Ins BEDROOM 2 4.1 12.0 0 8.0 0 96.0 0.149 0 0 0.20 0 %
1/12/2022 9:37:29 AM Page 3EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS(Continued)
___ 12 S=>N Exterior Conc. Blk - Int Ins BEDROOM 2 4.1 4.0 0 8.0 0 32.0 0.149 0 0 0.20 0 %
___ 13 N=>S Exterior Conc. Blk - Int Ins BEDROOM 3 4.1 13.0 0 8.0 0 104.0 0.149 0 0 0.20 0 %
___ 14 E=>W Exterior Conc. Blk - Int Ins BEDROOM 3 4.1 13.0 0 8.0 0 104.0 0.149 0 0 0.20 0 %
___ 15 N=>S Exterior Conc. Blk - Int Ins BATH 2 4.1 6.0 0 8.0 0 48.0 0.149 0 0 0.20 0 %
___ 16 N=>S Exterior Conc. Blk - Int Ins BEDROOM 4 4.1 15.0 0 8.0 0 120.0 0.149 0 0 0.20 0 %
___ 17 W=>E Exterior Conc. Blk - Int Ins BEDROOM 4 4.1 13.0 0 8.0 0 104.0 0.149 0 0 0.20 0 %
___ 18 N=>S Garage Frame - Wood BEDROOM 2 13.0 28.0 0 8.0 0 224.0 0.084 0 0.23 0.20 0 %
___ 19 N=>S Exterior Conc. Blk - Int Ins CABANA 4.1 10.0 0 8.0 0 80.0 0.149 0 0.20 0 %
___ 20 W=>E Exterior Conc. Blk - Int Ins CABANA 4.1 6.0 0 8.0 0 48.0 0.149 0 0.20 0 %
___ 21 N=>S Exterior Conc. Blk - Int Ins WIC 4 4.1 7.0 0 8.0 0 56.0 0.149 0 0.20 0 %
___ 22 E=>W Exterior Conc. Blk - Int Ins WIC 4 4.1 9.0 0 8.0 0 72.0 0.149 0 0.20 0 %
DOORS (Total Exposed Area = 37 sq.ft.)
Width Height
#Ornt Adjacent To Door Type Space Storms U-Value Ft In Ft In Area
___ 1 E=>W Insulated FOYER None 0.32 3.00 0 6.00 8 20.0ft²
___ 2 N=>S Insulated WIC 4 None 0.28 2.00 6 6.00 8 16.7ft²
WINDOWS (Total Exposed Area = 121 sq.ft.)
Wall -----Overhang-----
#Ornt ID Frame Panes NFRC U-Factor SHGC Imp Storm Area Depth Separation Interior Shade Screening
___ 1 W=>E 2 Vinyl Low-E Double Yes 0.30 0.29 Y N 15.0ft²2.0 ft 0 in 1.0 ft 4 in None None
___ 2 W=>E 6 Vinyl Low-E Double Yes 0.30 0.29 N N 20.0ft²2.0 ft 0 in 1.0 ft 4 in None None
___ 3 W=>E 7 Vinyl Low-E Double Yes 0.30 0.29 Y N 41.0ft²2.0 ft 0 in 1.0 ft 4 in None None
___ 4 E=>W 11 Vinyl Low-E Double Yes 0.30 0.29 Y N 15.0ft²2.0 ft 0 in 1.0 ft 4 in None None
___ 5 E=>W 14 Vinyl Low-E Double Yes 0.30 0.29 Y N 15.0ft²2.0 ft 0 in 1.0 ft 4 in None None
___ 6 W=>E 17 Vinyl Low-E Double Yes 0.30 0.29 Y N 15.0ft²2.0 ft 0 in 1.0 ft 4 in None None
INFILTRATION
#Scope Method SLA CFM50 ELA EqLA ACH ACH50 Space(s)
___ 1 Wholehouse Proposed ACH(50)0.00030 1648 90.41 169.73 0.0969 5.0 All
GARAGE
#Floor Area Roof Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
___ 1 380 ft²380 ft²28 ft 8 ft 13
MASS
#Mass Type Area Thickness Furniture Fraction Space
___ 1 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 MASTER BEDROOM
___ 2 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 WIC
___ 3 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 M BATH
___ 4 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 DINING
___ 5 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 KITCHEN
___ 6 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 GREAT ROOM
___ 7 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 UTILITY
___ 8 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 FOYER
___ 9 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 BEDROOM 2
___ 10 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 BEDROOM 3
1/12/2022 9:37:29 AM Page 4EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
MASS(Continued)
___ 11 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 BATH 2
___ 12 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 BEDROOM 4
___ 13 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 HALL
___ 14 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 CABANA
___ 15 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 WIC 4
HEATING SYSTEM
#System Type Subtype AHRI #Efficiency Capacity ----Geothermal HeatPump----Ducts Block
kBtu/hr Entry Power Volt Current
___ 1 Electric Strip Heat None COP: 1.00 27.0 0.00 0.00 0.00 sys#1 1
COOLING SYSTEM
#System Type Subtype/Speed AHRI #Efficiency Capacity Air Flow SHR Duct Block
kBtu/hr cfm
___ 1 Central Unit Split/Single SEER:16.0 35.4 1062 0.80 sys#1 1
HOT WATER SYSTEM
#System Type Subtype Location EF(UEF)Cap Use SetPnt Fixture Flow Pipe Ins.Pipe length
___ 1 Electric None Garage 0.93 (0.92)50.00 gal 61 gal 120 deg Standard None 98
Recirculation Recirc Control Loop Branch Pump DWHR Facilities Equal DWHR Other Credits
System Type length length power Connected Flow Eff
___ 1 No NA NA NA No NA NA NA None
DUCTS
Duct ---------Supply------------------Return---------Air CFM 25 CFM 25 HVAC #
#Location R-Value Area Location R-Value Area Leakage Type Handler TOT OUT QN RLF Heat Cool
___ 1 Attic 6.0 105 ft²Attic 6.0 45 ft²Proposed Qn UTILITY ------0.08 0.50 1 1
TEMPERATURES
Programable Thermostat: N Ceiling Fans: N
Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jun [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec
Heating [X] Jan [X] Feb [X] Mar [ ] Apr [ ] May [ ] Jun [ ] Jul [ ] Aug [ ] Sep [ ] Oct [X] Nov [X] Dec
Venting [ ] Jan [ ] Feb [X] Mar [X] Apr [ ] May [ ] Jun [ ] Jul [ ] Aug [ ] Sep [X] Oct [X] Nov [ ] Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
___ Cooling (WD)AM 78 78 78 78 78 78 78 78 78 78 78 78PM787878787878787878787878
___ Cooling (WEH)AM 78 78 78 78 78 78 78 78 78 78 78 78PM787878787878787878787878
___ Heating (WD)AM 68 68 68 68 68 68 68 68 68 68 68 68PM686868686868686868686868
___ Heating (WEH)AM 68 68 68 68 68 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 68 68
1/12/2022 9:37:29 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5
CHECK2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIAa
Project Name:FY SPEC 792 VERONA 2 MODEL Builder Name:SYNERGY HOMES, LLC
Street:2637 DYER RD.Permit Office:ST. LUCIE COUNTY
City, State, Zip:PORT ST. LUCIE, FL, Permit Number:
Owner:Jurisdiction:6611000
Design Location:FL, Fort Pierce County:St. Lucie(Florida Climate Zone 2)
COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA
General A continuous air barrier shall be installed in the building envelope.Air-permeable insulation shall
requirements The exterior thermal envelope contains a continuous air barrier.not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit
Ceiling/attic the insulation and any gaps in the air barrier shall be sealed.shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls The junction of the foundation and sill plate shall be sealed.Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with
sealed.a material having a thermal resistance of R-3 per
Knee walls shall be sealed.inch minimum
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights The space between window/door jambs and framing, and
and doors skylights and framing shall be sealed.
Rim joists Rim joists shall include the air barrier.Rim joists shall be insulated.
Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to
(including insulation.maintain permanent contact with the underside of
above-garage subfloor decking, or floor framing cavity insulation
and cantilevered shall be permitted to be in contact with the top side
floors)of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls Exposed earth in unvented crawl spaces shall be covered Where provided instead of floor insulation, insulation
with a Class I vapor retarder with overlapping joints taped.shall be permanently attached to the crawlspace walls.
Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation Air sealing shall be provided between the garage and
conditioned spaces.
Recessed lighting Recessed light fixtures installed in the building thermal Recessed light fixtures installed in the building
envelope shall be sealed to the finished surface.thermal envelope shall be air tight and IC rated.
Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind piping and wiring.
Shower/tub The air barrier installed at exterior walls adjacent to showers Exterior walls adjacent to showers and tubs shall
on exterior wall and tubs shall separate them from the showers and tubs.be insulated.
Electrical/phone box The air barrier shall be installed behind electrical or
on exterior walls communication boxes or air-sealed boxes shall be installed.
HVAC register boots HVAC supply and return register boots that penetrate building
thermal envelope shall be sealed to the sub-floor, wall covering
or ceiling penetrated by the boot.
Concealed When required to be sealed, concealed fire sprinklers shall only
sprinklers be sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
voids between fire sprinkler cover plates and walls or ceilings.
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
1/12/2022 9:37:29 AM EnergyGauge® USA 7.0 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1