Loading...
HomeMy WebLinkAboutapproved 8. EnergyCalcsFORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title:FY SPEC 792 VERONA 2 MODEL Address type:Street Address Building Type:Bedrooms:Lot #:User 4 --- Owner:Conditioned Area:Block/SubDivision:2069 --- Total Stories:PlatBook:1 --- Builder Name:Worst Case:Street:SYNERGY HOMES, LLC Yes 2637 DYER RD. Permit Office:Rotate Angle:County:ST. LUCIE COUNTY 180 St. Lucie Jurisdiction:Cross Ventilation:City, State, Zip:6611000 No PORT ST. LUCIE, Family Type:Whole House Fan: Detached No F L , New/Existing:Terrain: New (From Plans)Suburban Year Construct:Shielding: Suburban Comment: CLIMATE Design Design Temp Int Design Temp Heating Design Daily temp Location Tmy Site 97.5%2.5%Winter Summer Degree Days Moisture Range ___ FL, Fort Pierce FL_VERO_BEACH_MUNICIPA 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume ___ 1 Entire House 2069 19775 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Finished Cooled Heated ___ 1 MASTER BEDROOM 275 2475 No 2 1 Yes Yes Yes ___ 2 WIC 45 360 No 0 Yes Yes Yes ___ 3 M BATH 117 936 No 0 Yes Yes Yes ___ 4 DINING 156 1872 No 0 Yes Yes Yes ___ 5 KITCHEN 258 3096 Yes 0 No Yes Yes ___ 6 GREAT ROOM 323 3876 No 0 Yes Yes Yes ___ 7 UTILITY 64 512 No 0 Yes Yes Yes ___ 8 FOYER 55 440 No 0 Yes Yes Yes ___ 9 BEDROOM 2 180 1440 No 0 1 Yes Yes Yes ___ 10 BEDROOM 3 163 1304 No 0 1 Yes Yes Yes ___ 11 BATH 2 60 480 No 0 Yes Yes Yes ___ 12 BEDROOM 4 232 1856 No 0 1 Yes Yes Yes ___ 13 HALL 24 192 No 0 No Yes Yes ___ 14 CABANA 54 432 No 0 0 Yes Yes Yes ___ 15 WIC 4 63 504 No 0 0 Yes Yes Yes FLOORS (Total Exposed Area = 2069 sq.ft.) #Floor Type Space Exposed Perim Perimeter R-Value Area U-Factor Joist R-Value Tile Wood Carpet ___ 1 Slab-On-Grade Edge Ins MASTER BEDROOM 30 0 275 ft 0.473 ---0.00 1.00 0.00 ___ 2 Slab-On-Grade Edge Ins WIC 9 0 45 ft 0.473 ---0.00 1.00 0.00 ___ 3 Slab-On-Grade Edge Ins M BATH 9 0 117 ft 0.473 ---0.00 1.00 0.00 ___ 4 Slab-On-Grade Edge Ins DINING 24 0 156 ft 0.473 ---0.00 1.00 0.00 ___ 5 Slab-On-Grade Edge Ins KITCHEN 1 0 258 ft 0.473 ---0.00 1.00 0.00 ___ 6 Slab-On-Grade Edge Ins GREAT ROOM 17 0 323 ft 0.473 ---0.00 1.00 0.00 ___ 7 Slab-On-Grade Edge Ins UTILITY 7 0 64 ft 0.473 ---0.00 1.00 0.00 ___ 8 Slab-On-Grade Edge Ins FOYER 5 0 55 ft 0.473 ---0.00 1.00 0.00 ___ 9 Slab-On-Grade Edge Ins BEDROOM 2 16 0 180 ft 0.473 ---0.00 1.00 0.00 ___ 10 Slab-On-Grade Edge Ins BEDROOM 3 26 0 163 ft 0.473 ---0.00 1.00 0.00 ___ 11 Slab-On-Grade Edge Ins BATH 2 6 0 60 ft 0.473 ---0.00 1.00 0.00 1/12/2022 9:37:29 AM Page 2EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS(Continued) #Floor Type Space Exposed Perim Perimeter R-Value Area U-Factor Joist R-Value Tile Wood Carpet ___ 12 Slab-On-Grade Edge Ins BEDROOM 4 28 0 232 ft 0.473 ---0.00 1.00 0.00 ___ 13 Slab-On-Grade Edge Ins HALL 1 0 24 ft 0.473 ---0.00 1.00 0.00 ___ 14 Slab-On-Grade Edge Ins CABANA 25 0 54 ft 0.304 ---0.00 0.00 1.00 ___ 15 Slab-On-Grade Edge Ins WIC 4 30 0 63 ft 0.304 ---0.00 0.00 1.00 ROOF Roof Gable Roof SolarRad SA Emitt Emitt Deck Pitch #Type Materials Area Area Color Absor.Barr Tested Tested Insul.(deg) ___ 1 Hip Composition shingles 2241 ft²0 ft²Light N 0.5 No 0.6 No 20 22.62 ATTIC #Type Ventilation Vent Ratio (1 in)Area RBS IRCC ___ 1 Full attic Unvented 0 2069 ft²N N CEILING (Total Exposed Area = 2200 sq.ft.) #Ceiling Type Space R-Value Ins. Type Area U-Factor Framing Frac.Truss Type ___ 1 Under Attic(Unvented)MASTER BEDROOM 30.0 Blown 275.0ft²0.034 0.10 Wood ___ 2 Under Attic(Unvented)WIC 30.0 Blown 45.0ft²0.034 0.10 Wood ___ 3 Under Attic(Unvented)M BATH 30.0 Blown 117.0ft²0.034 0.10 Wood ___ 4 Under Attic(Unvented)DINING 30.0 Blown 156.0ft²0.034 0.10 Wood ___ 5 Under Attic(Unvented)KITCHEN 30.0 Blown 42.0ft²0.034 0.10 Wood ___ 6 Under Attic(Unvented)KITCHEN 30.0 Blown 270.0ft²0.034 0.00 Wood ___ 7 Under Attic(Unvented)GREAT ROOM 30.0 Blown 17.0ft²0.034 0.10 Wood ___ 8 Under Attic(Unvented)GREAT ROOM 30.0 Blown 383.0ft²0.034 0.00 Wood ___ 9 Under Attic(Unvented)UTILITY 30.0 Blown 64.0ft²0.034 0.10 Wood ___ 10 Under Attic(Unvented)FOYER 30.0 Blown 55.0ft²0.034 0.10 Wood ___ 11 Under Attic(Unvented)BEDROOM 2 30.0 Blown 180.0ft²0.034 0.10 Wood ___ 12 Under Attic(Unvented)BEDROOM 3 30.0 Blown 163.0ft²0.034 0.10 Wood ___ 13 Under Attic(Unvented)BATH 2 30.0 Blown 60.0ft²0.034 0.10 Wood ___ 14 Under Attic(Unvented)BEDROOM 4 30.0 Blown 232.0ft²0.034 0.10 Wood ___ 15 Under Attic(Unvented)HALL 30.0 Blown 24.0ft²0.034 0.10 Wood ___ 16 Under Attic(Unvented)CABANA 30.0 Blown 54.0ft²0.023 0.11 Wood ___ 17 Under Attic(Unvented)WIC 4 30.0 Blown 63.0ft²0.023 0.11 Wood WALLS (Total Exposed Area = 1967 sq.ft.) Note: First wall orientation below is as entered. Actual orientation is modified by the rotate angle (180 degrees) as shown in the "Project" section on page 1. Adjacent Cavity Width Height Area U-Sheath Frm.Solar Below #Ornt To Wall Type Space R-Value Ft In Ft In sq.ft.Factor R-Value Frac.Absor.Grade ___ 1 S=>N Exterior Conc. Blk - Int Ins MASTER BEDROOM 4.1 17.0 0 9.0 0 153.0 0.149 0 0 0.20 0 % ___ 2 W=>E Exterior Conc. Blk - Int Ins MASTER BEDROOM 4.1 13.0 0 9.0 0 117.0 0.149 0 0 0.20 0 % ___ 3 S=>N Exterior Conc. Blk - Int Ins WIC 4.1 9.0 0 8.0 0 72.0 0.149 0 0 0.20 0 % ___ 4 S=>N Exterior Conc. Blk - Int Ins M BATH 4.1 9.0 0 8.0 0 72.0 0.149 0 0 0.20 0 % ___ 5 N=>S Exterior Conc. Blk - Int Ins DINING 4.1 12.0 0 9.0 0 108.0 0.149 0 0 0.20 0 % ___ 6 W=>E Exterior Conc. Blk - Int Ins DINING 4.1 12.0 0 9.0 0 108.0 0.149 0 0 0.20 0 % ___ 7 W=>E Exterior Conc. Blk - Int Ins GREAT ROOM 4.1 13.0 7 11.0 3 152.8 0.149 0 0 0.20 0 % ___ 8 E=>W Exterior Conc. Blk - Int Ins UTILITY 4.1 6.0 0 8.0 0 48.0 0.149 0 0 0.20 0 % ___ 9 S=>N Exterior Conc. Blk - Int Ins UTILITY 4.1 1.0 0 8.0 0 8.0 0.149 0 0 0.20 0 % ___ 10 E=>W Exterior Conc. Blk - Int Ins FOYER 4.1 5.0 0 8.0 0 40.0 0.149 0 0 0.20 0 % ___ 11 E=>W Exterior Conc. Blk - Int Ins BEDROOM 2 4.1 12.0 0 8.0 0 96.0 0.149 0 0 0.20 0 % 1/12/2022 9:37:29 AM Page 3EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS(Continued) ___ 12 S=>N Exterior Conc. Blk - Int Ins BEDROOM 2 4.1 4.0 0 8.0 0 32.0 0.149 0 0 0.20 0 % ___ 13 N=>S Exterior Conc. Blk - Int Ins BEDROOM 3 4.1 13.0 0 8.0 0 104.0 0.149 0 0 0.20 0 % ___ 14 E=>W Exterior Conc. Blk - Int Ins BEDROOM 3 4.1 13.0 0 8.0 0 104.0 0.149 0 0 0.20 0 % ___ 15 N=>S Exterior Conc. Blk - Int Ins BATH 2 4.1 6.0 0 8.0 0 48.0 0.149 0 0 0.20 0 % ___ 16 N=>S Exterior Conc. Blk - Int Ins BEDROOM 4 4.1 15.0 0 8.0 0 120.0 0.149 0 0 0.20 0 % ___ 17 W=>E Exterior Conc. Blk - Int Ins BEDROOM 4 4.1 13.0 0 8.0 0 104.0 0.149 0 0 0.20 0 % ___ 18 N=>S Garage Frame - Wood BEDROOM 2 13.0 28.0 0 8.0 0 224.0 0.084 0 0.23 0.20 0 % ___ 19 N=>S Exterior Conc. Blk - Int Ins CABANA 4.1 10.0 0 8.0 0 80.0 0.149 0 0.20 0 % ___ 20 W=>E Exterior Conc. Blk - Int Ins CABANA 4.1 6.0 0 8.0 0 48.0 0.149 0 0.20 0 % ___ 21 N=>S Exterior Conc. Blk - Int Ins WIC 4 4.1 7.0 0 8.0 0 56.0 0.149 0 0.20 0 % ___ 22 E=>W Exterior Conc. Blk - Int Ins WIC 4 4.1 9.0 0 8.0 0 72.0 0.149 0 0.20 0 % DOORS (Total Exposed Area = 37 sq.ft.) Width Height #Ornt Adjacent To Door Type Space Storms U-Value Ft In Ft In Area ___ 1 E=>W Insulated FOYER None 0.32 3.00 0 6.00 8 20.0ft² ___ 2 N=>S Insulated WIC 4 None 0.28 2.00 6 6.00 8 16.7ft² WINDOWS (Total Exposed Area = 121 sq.ft.) Wall -----Overhang----- #Ornt ID Frame Panes NFRC U-Factor SHGC Imp Storm Area Depth Separation Interior Shade Screening ___ 1 W=>E 2 Vinyl Low-E Double Yes 0.30 0.29 Y N 15.0ft²2.0 ft 0 in 1.0 ft 4 in None None ___ 2 W=>E 6 Vinyl Low-E Double Yes 0.30 0.29 N N 20.0ft²2.0 ft 0 in 1.0 ft 4 in None None ___ 3 W=>E 7 Vinyl Low-E Double Yes 0.30 0.29 Y N 41.0ft²2.0 ft 0 in 1.0 ft 4 in None None ___ 4 E=>W 11 Vinyl Low-E Double Yes 0.30 0.29 Y N 15.0ft²2.0 ft 0 in 1.0 ft 4 in None None ___ 5 E=>W 14 Vinyl Low-E Double Yes 0.30 0.29 Y N 15.0ft²2.0 ft 0 in 1.0 ft 4 in None None ___ 6 W=>E 17 Vinyl Low-E Double Yes 0.30 0.29 Y N 15.0ft²2.0 ft 0 in 1.0 ft 4 in None None INFILTRATION #Scope Method SLA CFM50 ELA EqLA ACH ACH50 Space(s) ___ 1 Wholehouse Proposed ACH(50)0.00030 1648 90.41 169.73 0.0969 5.0 All GARAGE #Floor Area Roof Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation ___ 1 380 ft²380 ft²28 ft 8 ft 13 MASS #Mass Type Area Thickness Furniture Fraction Space ___ 1 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 MASTER BEDROOM ___ 2 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 WIC ___ 3 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 M BATH ___ 4 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 DINING ___ 5 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 KITCHEN ___ 6 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 GREAT ROOM ___ 7 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 UTILITY ___ 8 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 FOYER ___ 9 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 BEDROOM 2 ___ 10 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 BEDROOM 3 1/12/2022 9:37:29 AM Page 4EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT MASS(Continued) ___ 11 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 BATH 2 ___ 12 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 BEDROOM 4 ___ 13 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 HALL ___ 14 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 CABANA ___ 15 Default(8 lbs/sq.ft.)0 ft²0 ft 0.30 WIC 4 HEATING SYSTEM #System Type Subtype AHRI #Efficiency Capacity ----Geothermal HeatPump----Ducts Block kBtu/hr Entry Power Volt Current ___ 1 Electric Strip Heat None COP: 1.00 27.0 0.00 0.00 0.00 sys#1 1 COOLING SYSTEM #System Type Subtype/Speed AHRI #Efficiency Capacity Air Flow SHR Duct Block kBtu/hr cfm ___ 1 Central Unit Split/Single SEER:16.0 35.4 1062 0.80 sys#1 1 HOT WATER SYSTEM #System Type Subtype Location EF(UEF)Cap Use SetPnt Fixture Flow Pipe Ins.Pipe length ___ 1 Electric None Garage 0.93 (0.92)50.00 gal 61 gal 120 deg Standard None 98 Recirculation Recirc Control Loop Branch Pump DWHR Facilities Equal DWHR Other Credits System Type length length power Connected Flow Eff ___ 1 No NA NA NA No NA NA NA None DUCTS Duct ---------Supply------------------Return---------Air CFM 25 CFM 25 HVAC # #Location R-Value Area Location R-Value Area Leakage Type Handler TOT OUT QN RLF Heat Cool ___ 1 Attic 6.0 105 ft²Attic 6.0 45 ft²Proposed Qn UTILITY ------0.08 0.50 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: N Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jun [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec Heating [X] Jan [X] Feb [X] Mar [ ] Apr [ ] May [ ] Jun [ ] Jul [ ] Aug [ ] Sep [ ] Oct [X] Nov [X] Dec Venting [ ] Jan [ ] Feb [X] Mar [X] Apr [ ] May [ ] Jun [ ] Jul [ ] Aug [ ] Sep [X] Oct [X] Nov [ ] Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 ___ Cooling (WD)AM 78 78 78 78 78 78 78 78 78 78 78 78PM787878787878787878787878 ___ Cooling (WEH)AM 78 78 78 78 78 78 78 78 78 78 78 78PM787878787878787878787878 ___ Heating (WD)AM 68 68 68 68 68 68 68 68 68 68 68 68PM686868686868686868686868 ___ Heating (WEH)AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 1/12/2022 9:37:29 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 CHECK2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIAa Project Name:FY SPEC 792 VERONA 2 MODEL Builder Name:SYNERGY HOMES, LLC Street:2637 DYER RD.Permit Office:ST. LUCIE COUNTY City, State, Zip:PORT ST. LUCIE, FL, Permit Number: Owner:Jurisdiction:6611000 Design Location:FL, Fort Pierce County:St. Lucie(Florida Climate Zone 2) COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope.Air-permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier.not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit Ceiling/attic the insulation and any gaps in the air barrier shall be sealed.shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed.Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed.a material having a thermal resistance of R-3 per Knee walls shall be sealed.inch minimum Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier.Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation.maintain permanent contact with the underside of above-garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors)of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered Where provided instead of floor insulation, insulation with a Class I vapor retarder with overlapping joints taped.shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal Recessed light fixtures installed in the building envelope shall be sealed to the finished surface.thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers Exterior walls adjacent to showers and tubs shall on exterior wall and tubs shall separate them from the showers and tubs.be insulated. Electrical/phone box The air barrier shall be installed behind electrical or on exterior walls communication boxes or air-sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub-floor, wall covering or ceiling penetrated by the boot. Concealed When required to be sealed, concealed fire sprinklers shall only sprinklers be sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids voids between fire sprinkler cover plates and walls or ceilings. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 1/12/2022 9:37:29 AM EnergyGauge® USA 7.0 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1