Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
approved 9. Manual J
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Jan-12 09:21:41Right-Suite® Universal 2021 21.0.08 RSU08101 Page 1...GY-VERONA 2-GARGE LEFT-FY SPEC 792 DYER RD..rup Calc = MJ8 Front Door faces: NE Job:Project Summary Date:Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM Project Information FY SPEC 792 VERONA 2 MODELFor:2673 DYER ROAD, PORT ST. LUCIE, FL Notes: Design Information Fort Pierce, FL, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F42 Outside db °F90Inside db °F70 Inside db °F75Design TD °F28 Design TD °F15Daily range MRelative humidity %50Moisture difference gr/lb61 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh25107 Structure Btuh20247Ducts Btuh4308 Ducts Btuh3162Central vent (0 cfm) Btuh0 Central vent (0 cfm) Btuh0(none) (none)Humidification Btuh0 Blower Btuh0Piping Btuh0Equipment load Btuh29414 Use manufacturer's data nRate/swing multiplier 0.95InfiltrationEquipment sensible load Btuh22239 Method Latent Cooling Equipment Load SizingSimplifiedConstruction quality Average0Fireplaces Structure Btuh3708Ducts Btuh2365Central vent (0 cfm) Btuh0CoolingHeating(none)20692069Area (ft²) Equipment latent load Btuh60731892618926Volume (ft³)Air changes/hour 0.160.32 Equipment Total Load (Sen+Lat)Btuh28313Equiv. AVF (cfm) 50101 Req. total capacity at 0.70 SHR ton2.6 Heating Equipment Summary Cooling Equipment Summary Make RHEEM Make RheemTrade Trade RHEEMModel Cond RA1636AJ1NBRHCAHRI ref Coil RH1T3617STANJAAHRI ref 7942207Efficiency 100 EFF Efficiency 13.0 EER, 16 SEERHeating input kW8.0 Sensible cooling Btuh24780Heating output Btuh27297 Latent cooling Btuh10620Temperature rise °F65 Total cooling Btuh35400Actual air flow cfm385 Actual air flow cfm1180Air flow factor cfm/Btuh0.013 Air flow factor cfm/Btuh0.050Static pressure in H2O0.50 Static pressure in H2O0.50Space thermostat Load sensible heat ratio 0.79 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Jan-12 09:21:41Right-Suite® Universal 2021 21.0.08 RSU08101 Page 1...GY-VERONA 2-GARGE LEFT-FY SPEC 792 DYER RD..rup Calc = MJ8 Front Door faces: NE Job:Right-J® Worksheet Date:Entire House By:QUICK CALCS, INC. 317 ST. LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM 1 Room name Entire House MASTER BEDROOM 2 Exposed wall 226.0 ft 30.0 ft3Room height 9.1 ft 9.0 heat/coolft 4 Room dimensions ft275.0x1.05Room area 2069.0 ft²275.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Loadnumber(Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 485 470 1882 1028 0 0 0 0.GG 1A-r1om1A-r1om 1.2701.270 nn 35.5635.56 26.3926.39 15 0 533 396 0 0 0 0.WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 288 237 949 519 0 0 0 0.GG 1A-r1om1A-r1om 1.2701.270 ee 35.5635.56 50.7950.79 30 2 1067 1524 0 0 0 011DD11D011D00.3900.390 ee 10.9210.92 10.3410.34 21 21 229 217 0 0 0 0WW13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 442 424 1699 929 153 153 613 335DD11D011D00.3900.390 ss 10.9210.92 10.3410.34 18 18 192 182 0 0 0 0WW13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 495 419 1678 917 117 102 408 223 GG 1A-r1om1A-r1om 1.2701.270 ww 35.5635.56 50.7950.79 15 1 533 762 15 1 533 762GG1A-r1om1A-r1om 1.2701.270 ww 35.5635.56 50.7950.79 20 1 711 1016 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 ww 35.5635.56 51.2951.29 41 2 1451 2093 0 0 0 0PP12C-0sw12C-0sw 0.0910.091 --2.552.55 1.061.06 206 206 525 217 0 0 0 0CC16B-30ad16B-30ad 0.0320.032 --0.900.90 1.601.60 117 117 105 187 0 0 0 0CC16X19-0ad16X19-0ad 0.4080.408 --1.591.59 1.371.37 1430 1430 2267 1956 275 275 436 376CC17B-6al17B-6al 0.1050.105 --2.942.94 4.304.30 653 653 1920 2811 0 0 0 0FF22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 2069 226 6258 0 275 30 831 0 6 c) AED excursion 923 205 Envelope loss/gain 22000 15675 2821 1901 12 a) Infiltration 3106 832 490 131 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 8 1840 2 460 Appliances/other 1900 900 Subtotal (lines 6 to 13)25107 20247 3312 3393 Less external loadLess external load 0 0 0 0Less transferLess transfer 0 0 0 0RedistributionRedistribution000014Subtotal251072024733123393 15 Duct loads 17%16%4308 3162 17%15%557 510 Total room load 29414 23410 3869 3903Air required (cfm)Air required (cfm)385 1180 51 197 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Jan-12 09:21:41Right-Suite® Universal 2021 21.0.08 RSU08101 Page 2...GY-VERONA 2-GARGE LEFT-FY SPEC 792 DYER RD..rup Calc = MJ8 Front Door faces: NE Job:Right-J® Worksheet Date:Entire House By:QUICK CALCS, INC. 317 ST. LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM 1 Room name WIC M BATH 2 Exposed wall 9.0 ft 22.0 ft3Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft9.0x5.0 ft9.0x13.05Room area 45.0 ft²117.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Loadnumber(Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 0 0 0 0 0 0 0 0.GG 1A-r1om1A-r1om 1.2701.270 nn 35.5635.56 26.3926.39 0 0 0 0 0 0 0 0.WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 0 0 0 0 0 0 0 0.GG 1A-r1om1A-r1om 1.2701.270 ee 35.5635.56 50.7950.79 0 0 0 0 0 0 0 011DD11D011D00.3900.390 ee 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0WW13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 72 72 288 158 72 72 288 158DD11D011D00.3900.390 ss 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0WW13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 0 0 0 0 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 ww 35.5635.56 50.7950.79 0 0 0 0 0 0 0 0GG1A-r1om1A-r1om 1.2701.270 ww 35.5635.56 50.7950.79 0 0 0 0 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 ww 35.5635.56 51.2951.29 0 0 0 0 0 0 0 0PP12C-0sw12C-0sw 0.0910.091 --2.552.55 1.061.06 0 0 0 0 104 104 265 110CC16B-30ad16B-30ad 0.0320.032 --0.900.90 1.601.60 0 0 0 0 117 117 105 187CC16X19-0ad16X19-0ad 0.4080.408 --1.591.59 1.371.37 45 45 71 62 0 0 0 0CC17B-6al17B-6al 0.1050.105 --2.942.94 4.304.30 0 0 0 0 0 0 0 0FF22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 45 9 249 0 117 22 609 0 6 c) AED excursion -8 -15 Envelope loss/gain 609 211 1267 439 12 a) Infiltration 131 35 131 35 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)740 246 1398 474 Less external loadLess external load 0 0 0 0Less transferLess transfer 0 0 0 0RedistributionRedistribution000014Subtotal7402461398474 15 Duct loads 17%15%124 37 23%40%320 188 Total room load 864 283 1718 662Air required (cfm)Air required (cfm)11 14 22 33 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Jan-12 09:21:41Right-Suite® Universal 2021 21.0.08 RSU08101 Page 3...GY-VERONA 2-GARGE LEFT-FY SPEC 792 DYER RD..rup Calc = MJ8 Front Door faces: NE Job:Right-J® Worksheet Date:Entire House By:QUICK CALCS, INC. 317 ST. LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM 1 Room name DINING KITCHEN 2 Exposed wall 24.0 ft 6.0 ft3Room height 9.0 heat/coolft 11.0 heat/coolft 4 Room dimensions ft13.0x12.0 ft258.0x1.05Room area 156.0 ft²258.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Loadnumber(Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 108 108 432 236 0 0 0 0.GG 1A-r1om1A-r1om 1.2701.270 nn 35.5635.56 26.3926.39 0 0 0 0 0 0 0 0.WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 0 0 0 0 0 0 0 0.GG 1A-r1om1A-r1om 1.2701.270 ee 35.5635.56 50.7950.79 0 0 0 0 0 0 0 011DD11D011D00.3900.390 ee 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0WW13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 0 0 0 0 0 0 0 0DD11D011D00.3900.390 ss 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0WW13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 108 88 352 193 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 ww 35.5635.56 50.7950.79 0 0 0 0 0 0 0 0GG1A-r1om1A-r1om 1.2701.270 ww 35.5635.56 50.7950.79 20 1 711 1016 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 ww 35.5635.56 51.2951.29 0 0 0 0 0 0 0 0PP12C-0sw12C-0sw 0.0910.091 --2.552.55 1.061.06 0 0 0 0 54 54 138 57CC16B-30ad16B-30ad 0.0320.032 --0.900.90 1.601.60 0 0 0 0 0 0 0 0CC16X19-0ad16X19-0ad 0.4080.408 --1.591.59 1.371.37 156 156 247 213 42 42 67 57CC17B-6al17B-6al 0.1050.105 --2.942.94 4.304.30 0 0 0 0 270 270 794 1163FF22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 156 24 665 0 258 6 166 0 6 c) AED excursion 352 -72 Envelope loss/gain 2408 2010 1165 1206 12 a) Infiltration 392 105 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 1000 Subtotal (lines 6 to 13)2800 2115 1165 2206 Less external loadLess external load 0 0 0 0Less transferLess transfer 0 0 0 0RedistributionRedistribution000014Subtotal2800211511652206 15 Duct loads 17%15%471 318 17%15%196 332 Total room load 3271 2433 1361 2538Air required (cfm)Air required (cfm)43 123 18 128 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Jan-12 09:21:41Right-Suite® Universal 2021 21.0.08 RSU08101 Page 4...GY-VERONA 2-GARGE LEFT-FY SPEC 792 DYER RD..rup Calc = MJ8 Front Door faces: NE Job:Right-J® Worksheet Date:Entire House By:QUICK CALCS, INC. 317 ST. LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM 1 Room name GREAT ROOM UTILITY 2 Exposed wall 17.0 ft 13.0 ft3Room height 11.3 heat/coolft 8.0 heat/coolft 4 Room dimensions ft19.0x17.0 ft62.0x1.05Room area 323.0 ft²62.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Loadnumber(Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 0 0 0 0 0 0 0 0.GG 1A-r1om1A-r1om 1.2701.270 nn 35.5635.56 26.3926.39 0 0 0 0 0 0 0 0.WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 0 0 0 0 48 48 192 105.GG 1A-r1om1A-r1om 1.2701.270 ee 35.5635.56 50.7950.79 0 0 0 0 0 0 0 011DD11D011D00.3900.390 ee 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0WW13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 0 0 0 0 8 8 32 18DD11D011D00.3900.390 ss 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0WW13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 153 112 449 245 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 ww 35.5635.56 50.7950.79 0 0 0 0 0 0 0 0GG1A-r1om1A-r1om 1.2701.270 ww 35.5635.56 50.7950.79 0 0 0 0 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 ww 35.5635.56 51.2951.29 41 2 1451 2093 0 0 0 0PP12C-0sw12C-0sw 0.0910.091 --2.552.55 1.061.06 0 0 0 0 48 48 122 51CC16B-30ad16B-30ad 0.0320.032 --0.900.90 1.601.60 0 0 0 0 0 0 0 0CC16X19-0ad16X19-0ad 0.4080.408 --1.591.59 1.371.37 17 17 27 23 62 62 98 85CC17B-6al17B-6al 0.1050.105 --2.942.94 4.304.30 383 383 1125 1648 0 0 0 0FF22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 323 17 471 0 62 13 360 0 6 c) AED excursion 675 -9 Envelope loss/gain 3523 4684 805 249 12 a) Infiltration 278 74 102 27 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 2 460 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)3801 5218 907 276 Less external loadLess external load 0 0 0 0Less transferLess transfer 0 0 0 0RedistributionRedistribution000014Subtotal38015218907276 15 Duct loads 17%15%639 785 17%15%153 42 Total room load 4440 6003 1059 318Air required (cfm)Air required (cfm)58 303 14 16 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Jan-12 09:21:41Right-Suite® Universal 2021 21.0.08 RSU08101 Page 5...GY-VERONA 2-GARGE LEFT-FY SPEC 792 DYER RD..rup Calc = MJ8 Front Door faces: NE Job:Right-J® Worksheet Date:Entire House By:QUICK CALCS, INC. 317 ST. LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM 1 Room name FOYER BEDROOM 2 2 Exposed wall 5.0 ft 16.0 ft3Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft11.0x5.0 ft15.0x12.05Room area 55.0 ft²180.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Loadnumber(Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 0 0 0 0 0 0 0 0.GG 1A-r1om1A-r1om 1.2701.270 nn 35.5635.56 26.3926.39 0 0 0 0 0 0 0 0.WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 40 19 76 42 96 81 324 177.GG 1A-r1om1A-r1om 1.2701.270 ee 35.5635.56 50.7950.79 0 0 0 0 15 1 533 76211DD11D011D00.3900.390 ee 10.9210.92 10.3410.34 21 21 229 217 0 0 0 0WW13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 0 0 0 0 32 32 128 70DD11D011D00.3900.390 ss 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0WW13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 0 0 0 0 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 ww 35.5635.56 50.7950.79 0 0 0 0 0 0 0 0GG1A-r1om1A-r1om 1.2701.270 ww 35.5635.56 50.7950.79 0 0 0 0 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 ww 35.5635.56 51.2951.29 0 0 0 0 0 0 0 0PP12C-0sw12C-0sw 0.0910.091 --2.552.55 1.061.06 0 0 0 0 0 0 0 0CC16B-30ad16B-30ad 0.0320.032 --0.900.90 1.601.60 0 0 0 0 0 0 0 0CC16X19-0ad16X19-0ad 0.4080.408 --1.591.59 1.371.37 55 55 87 75 180 180 285 246CC17B-6al17B-6al 0.1050.105 --2.942.94 4.304.30 0 0 0 0 0 0 0 0FF22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 55 5 138 0 180 16 443 0 6 c) AED excursion -11 -49 Envelope loss/gain 531 323 1714 1207 12 a) Infiltration 73 19 233 62 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 1 230 Appliances/other 0 0 Subtotal (lines 6 to 13)604 342 1947 1499 Less external loadLess external load 0 0 0 0Less transferLess transfer 0 0 0 0RedistributionRedistribution000014Subtotal60434219471499 15 Duct loads 17%15%102 51 17%15%328 226 Total room load 705 394 2274 1725Air required (cfm)Air required (cfm)9 20 30 87 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Jan-12 09:21:41Right-Suite® Universal 2021 21.0.08 RSU08101 Page 6...GY-VERONA 2-GARGE LEFT-FY SPEC 792 DYER RD..rup Calc = MJ8 Front Door faces: NE Job:Right-J® Worksheet Date:Entire House By:QUICK CALCS, INC. 317 ST. LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM 1 Room name BEDROOM 3 BATH 2 2 Exposed wall 26.0 ft 6.0 ft3Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft163.0x1.0 ft6.0x10.05Room area 163.0 ft²60.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Loadnumber(Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 104 104 416 228 48 48 192 105.GG 1A-r1om1A-r1om 1.2701.270 nn 35.5635.56 26.3926.39 0 0 0 0 0 0 0 0.WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 104 89 356 195 0 0 0 0.GG 1A-r1om1A-r1om 1.2701.270 ee 35.5635.56 50.7950.79 15 1 533 762 0 0 0 011DD11D011D00.3900.390 ee 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0WW13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 0 0 0 0 0 0 0 0DD11D011D00.3900.390 ss 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0WW13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 0 0 0 0 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 ww 35.5635.56 50.7950.79 0 0 0 0 0 0 0 0GG1A-r1om1A-r1om 1.2701.270 ww 35.5635.56 50.7950.79 0 0 0 0 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 ww 35.5635.56 51.2951.29 0 0 0 0 0 0 0 0PP12C-0sw12C-0sw 0.0910.091 --2.552.55 1.061.06 0 0 0 0 0 0 0 0CC16B-30ad16B-30ad 0.0320.032 --0.900.90 1.601.60 0 0 0 0 0 0 0 0CC16X19-0ad16X19-0ad 0.4080.408 --1.591.59 1.371.37 163 163 258 223 60 60 95 82CC17B-6al17B-6al 0.1050.105 --2.942.94 4.304.30 0 0 0 0 0 0 0 0FF22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 163 26 720 0 60 6 166 0 6 c) AED excursion -55 -7 Envelope loss/gain 2285 1353 453 180 12 a) Infiltration 378 101 87 23 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 1 230 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)2662 1684 541 204 Less external loadLess external load 0 0 0 0Less transferLess transfer 0 0 0 0RedistributionRedistribution000014Subtotal26621684541204 15 Duct loads 17%15%448 253 17%15%91 31 Total room load 3110 1937 632 235Air required (cfm)Air required (cfm)41 98 8 12 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Jan-12 09:21:41Right-Suite® Universal 2021 21.0.08 RSU08101 Page 7...GY-VERONA 2-GARGE LEFT-FY SPEC 792 DYER RD..rup Calc = MJ8 Front Door faces: NE Job:Right-J® Worksheet Date:Entire House By:QUICK CALCS, INC. 317 ST. LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM 1 Room name BEDROOM 4 HALL 2 Exposed wall 21.0 ft 0 ft3Room height 8.0 heat/coolft 8.0 heat/coolft 4 Room dimensions ft18.0x13.0 ft8.0x3.05Room area 234.0 ft²24.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Loadnumber(Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 144 129 517 282 0 0 0 0.GG 1A-r1om1A-r1om 1.2701.270 nn 35.5635.56 26.3926.39 15 0 533 396 0 0 0 0.WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 0 0 0 0 0 0 0 0.GG 1A-r1om1A-r1om 1.2701.270 ee 35.5635.56 50.7950.79 0 0 0 0 0 0 0 011DD11D011D00.3900.390 ee 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0WW13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 24 24 96 53 0 0 0 0DD11D011D00.3900.390 ss 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0WW13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 0 0 0 0 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 ww 35.5635.56 50.7950.79 0 0 0 0 0 0 0 0GG1A-r1om1A-r1om 1.2701.270 ww 35.5635.56 50.7950.79 0 0 0 0 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 ww 35.5635.56 51.2951.29 0 0 0 0 0 0 0 0PP12C-0sw12C-0sw 0.0910.091 --2.552.55 1.061.06 0 0 0 0 0 0 0 0CC16B-30ad16B-30ad 0.0320.032 --0.900.90 1.601.60 0 0 0 0 0 0 0 0CC16X19-0ad16X19-0ad 0.4080.408 --1.591.59 1.371.37 234 234 371 320 24 24 38 33CC17B-6al17B-6al 0.1050.105 --2.942.94 4.304.30 0 0 0 0 0 0 0 0FF22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 234 21 582 0 24 0 0 0 6 c) AED excursion -50 -1 Envelope loss/gain 2099 1001 38 32 12 a) Infiltration 305 82 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 2 460 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)2404 1542 38 32 Less external loadLess external load 0 0 0 0Less transferLess transfer 0 0 0 0RedistributionRedistribution000014Subtotal240415423832 15 Duct loads 17%15%404 232 17%15%6 5 Total room load 2808 1774 44 37Air required (cfm)Air required (cfm)37 89 1 2 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Jan-12 09:21:41Right-Suite® Universal 2021 21.0.08 RSU08101 Page 8...GY-VERONA 2-GARGE LEFT-FY SPEC 792 DYER RD..rup Calc = MJ8 Front Door faces: NE Job:Right-J® Worksheet Date:Entire House By:QUICK CALCS, INC. 317 ST. LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM 1 Room name WIC 4 CABANA 2 Exposed wall 16.0 ft 15.0 ft3Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft9.0x7.0 ft9.0x6.05Room area 63.0 ft²54.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Loadnumber(Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 81 81 324 177 0 0 0 0.GG 1A-r1om1A-r1om 1.2701.270 nn 35.5635.56 26.3926.39 0 0 0 0 0 0 0 0.WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 0 0 0 0 0 0 0 0.GG 1A-r1om1A-r1om 1.2701.270 ee 35.5635.56 50.7950.79 0 0 0 0 0 0 0 011DD11D011D00.3900.390 ee 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0WW13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 0 0 0 0 81 63 254 139DD11D011D00.3900.390 ss 10.9210.92 10.3410.34 0 0 0 0 18 18 192 182WW13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 63 63 252 138 54 54 216 118 GG 1A-r1om1A-r1om 1.2701.270 ww 35.5635.56 50.7950.79 0 0 0 0 0 0 0 0GG1A-r1om1A-r1om 1.2701.270 ww 35.5635.56 50.7950.79 0 0 0 0 0 0 0 0 GG 1A-r1om1A-r1om 1.2701.270 ww 35.5635.56 51.2951.29 0 0 0 0 0 0 0 0PP12C-0sw12C-0sw 0.0910.091 --2.552.55 1.061.06 0 0 0 0 0 0 0 0CC16B-30ad16B-30ad 0.0320.032 --0.900.90 1.601.60 0 0 0 0 0 0 0 0CC16X19-0ad16X19-0ad 0.4080.408 --1.591.59 1.371.37 63 63 100 86 54 54 86 74CC17B-6al17B-6al 0.1050.105 --2.942.94 4.304.30 0 0 0 0 0 0 0 0FF22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 63 16 443 0 54 15 415 0 6 c) AED excursion -15 -18 Envelope loss/gain 1120 386 1163 494 12 a) Infiltration 262 70 245 66 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)1381 457 1408 560 Less external loadLess external load 0 0 0 0Less transferLess transfer 0 0 0 0RedistributionRedistribution000014Subtotal13814571408560 15 Duct loads 17%15%232 69 17%15%237 84 Total room load 1613 525 1645 644Air required (cfm)Air required (cfm)21 26 22 32 2022-Jan-12 09:21:42 Right-Suite® Universal 2021 21.0.08 RSU08101 Page 1 ...GY-VERONA 2-GARGE LEFT-FY SPEC 792 DYER RD..rup Calc = MJ8 Front Door faces: NE Job:Manual S Compliance Report Date:Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM Project Information FY SPEC 792 VERONA 2 MODELFor: 2673 DYER ROAD, PORT ST. LUCIE, FL Cooling Equipment Design Conditions °F75.2Entering coil DB:Btuh23410Sensible gain:°F90.0Outdoor design DB: °F63.0Entering coil WB:Btuh6073Latent gain:°F78.0Outdoor design WB: Btuh29483Total gain:°F75.0Indoor design DB: cfm1180Estimated airflow:%50Indoor RH: Manufacturer's Performance Data at Actual Design Conditions Split ACEquipment type: RA1636AJ1NBRHC+RH1T3617STANJAModel:RheemManufacturer: cfm1180Actual airflow: % of load106Btuh24780Sensible capacity: % of load175Btuh10620Latent capacity: %70SHR:% of load120Btuh35400Total capacity: Heating Equipment Design Conditions °F69.4Entering coil DB:Btuh29414Heat loss:°F42.0Outdoor design DB: °F70.0Indoor design DB: Manufacturer's Performance Data at Actual Design Conditions Elec stripEquipment type: Model:RHEEMManufacturer: cfm385Actual airflow: °F65Temp. rise:% of load93kW8.0Output capacity: Meets all requirements of ACCA Manual S. 2022-Jan-12 09:21:42 Right-Suite® Universal 2021 21.0.08 RSU08101 Page 1 ...GY-VERONA 2-GARGE LEFT-FY SPEC 792 DYER RD..rup Calc = MJ8 Front Door faces: NE Job:Duct System Summary Date:Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM Project Information FY SPEC 792 VERONA 2 MODELFor: 2673 DYER ROAD, PORT ST. LUCIE, FL CoolingHeating External static pressure in H2O0.50in H2O0.50 Pressure losses in H2O0.28in H2O0.28 Available static pressure in H2O0.22in H2O0.22 Supply / return available pressure 0.110 / 0.110 in H2O in H2O0.110 / 0.110 Lowest friction rate in/100ft0.080in/100ft0.080 Actual air flow cfm1180cfm385 Total effective length (TEL) ft153 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm) (cfm)FR (in)(in)Matl Ln (ft)Ln (ft) Trunk st290.022.1VlFx0x04.00.080128235cBATH 2 st290.031.5VlFx0x06.00.08087301725cBEDROOM 2 st290.028.0VlFx0x06.00.08098411937cBEDROOM 3 st3110.043.1VlFx0x07.00.08089371774cBEDROOM 4 st3110.042.2VlFx0x05.00.0803222644cCABANA st190.032.5VlFx0x07.00.080123432433cDINING 70.07.1VlFx0x04.00.080209394cFOYER st290.032.3VlFx0x07.00.080151293002cGREAT ROOM st290.022.6VlFx0x07.00.080151293002cGREAT ROOM-A 00VlFx0x04.00.0802137cHALL 70.07.2VlFx0x08.00.080128182538cKITCHEN 70.015.0VlFx0x04.00.0803322662cM BATH st190.026.2VlFx0x06.00.08098251951cMASTER BEDROOM st190.024.1VlFx0x06.00.08098251951cMASTER BEDROOM-A 70.04.1VlFx0x04.00.0801614318cUTILITY st190.027.6VlFx0x04.00.0801411283cWIC st3110.043.4VlFx0x04.00.0802621525cWIC 4 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st3 Peak AVF 79 148 0.080 272 10.0 0x0 VinlFlx st2 st2 Peak AVF 216 647 0.080 824 12.0 0x0 VinlFlx st1 Peak AVF 105 334 0.080 612 10.0 0x0 VinlFlx 2022-Jan-12 09:21:42 Right-Suite® Universal 2021 21.0.08 RSU08101 Page 2 ...GY-VERONA 2-GARGE LEFT-FY SPEC 792 DYER RD..rup Calc = MJ8 Front Door faces: NE Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in) Matl Trunk rb1 0x 3850 1180 0 0 0 0 x0 0 VlFx