Loading...
HomeMy WebLinkAboutELECTRICAL LOAD CALCULATIONSS ELECTRICAL SERVICES, INC. `•-" "` STATE CERT. LIC EC13003715 3400 St Johns Pkwy S T RA A HOLDER: JOSEPH STRADA Sanford, FL NEC 2014/FBC 107 877-906-1113 ELECTRIC. SECURITY ELECTRICAL LOAD CALCULATIONS lIPDATEd 54-2018 MODEL: BUILDER: MARONDA HOMES SUBDIVISON: VOLT/AMPS TON CITY KW LARGEST LOAD: HEAT PUMPS W/SUPPLEMENTAL HEAT* 6290 2 4032 10000 6500 0 *Includes Heat Pump and Heat Strips on together @ 100% 2.5 5040 10000 6500 0 3 5280 10000 6600 0 Square Feet Living Area 1 8 3 Volt/Amps 4638 15 6168 8000 5200 0 Small Appliance Circuits 3 4500 4 6888 8000 5200 0 Laundry Circuit 1 1500 5 8160 10000 6500 0 Dishwasher 1 1500 Water Heater 1 4500 1 10 KW SETUP 0 Range 1 8000 1 AC EP1 .35.5 12 2.958333 Oven 0 2,576667 Cooktop 0 Microwave 1 1100 Dryer 1 5000 Disposal 1 500 Pool 0 Mlsc: Misc: TOTAL OTHER LOAD: 31238 FIRST 10KVA @ 100%: 10000 REMAINDER @ 40%; 8495 LARGEST LOAD: 8290 TOTAL LOAD: 26785 VA : 240 VOLTS = 112 t1 f )r EI fX I {}{y ([ RECOMMENDED 150 MINIMUM PER NEC: 150.`+ SERVICE SIZE: Nate: This Load Call is based on the information provided by the builder. The recommended service size will be installed leaving sufficient'usage for future homeowner. DO NOT SCALE TERRAIN - ELEVAMON METER MAIN COMBO 150AMP NEMA3R OR 200AMP NEMA 3R WIRE SCHEDULE I TO POWER CO- TRANSFORMER 2 M4 RARE COPPER 3 2/0 SER AL ( FOR I SDAMP) OR 4M SER (FOR 200AMP) AL PER NEC TO POWER CO. TRANSFORMER BY UTILITY COI INTERSYSTEM BOUNDING TERMINATION AS PER NEC 250.94 BOND TO FOUNDATION STEEL AS PER NEC 250.52(3) i RISER DIAGRAM N.T.S. 154A.RH REVISEVS/l/2620 Ronald Maronda Homes LLC of' FL Imo' Rayf 21# Mechanical one CFC1430061 CAC1820196 Cry #3���� 15V-( /jde � Digitally signed CAJason,- ,byJason James r, _ -.Date:, 20 2 s 1.11.03 James.,.',, 09:24:21—04'00'