HomeMy WebLinkAboutELECTRICAL LOAD CALCULATIONSS
ELECTRICAL SERVICES, INC.
`•-" "`
STATE CERT. LIC EC13003715
3400 St Johns Pkwy
S T
RA A
HOLDER: JOSEPH STRADA
Sanford, FL
NEC 2014/FBC 107
877-906-1113
ELECTRIC. SECURITY
ELECTRICAL LOAD CALCULATIONS
lIPDATEd 54-2018
MODEL:
BUILDER:
MARONDA HOMES
SUBDIVISON:
VOLT/AMPS
TON CITY KW
LARGEST LOAD: HEAT PUMPS W/SUPPLEMENTAL HEAT* 6290
2
4032 10000 6500
0
*Includes Heat Pump
and Heat Strips on together @ 100%
2.5
5040 10000 6500
0
3
5280 10000 6600
0
Square Feet Living Area 1 8
3 Volt/Amps 4638
15
6168 8000 5200
0
Small Appliance Circuits 3
4500
4
6888 8000 5200
0
Laundry Circuit 1
1500
5
8160 10000 6500
0
Dishwasher 1
1500
Water Heater 1
4500
1 10 KW SETUP
0
Range 1
8000
1 AC EP1 .35.5 12 2.958333
Oven
0 2,576667
Cooktop
0
Microwave 1
1100
Dryer 1
5000
Disposal 1
500
Pool
0
Mlsc:
Misc:
TOTAL OTHER LOAD:
31238
FIRST 10KVA @ 100%: 10000
REMAINDER @ 40%; 8495
LARGEST LOAD: 8290
TOTAL LOAD: 26785 VA : 240 VOLTS = 112
t1 f )r
EI
fX
I
{}{y ([
RECOMMENDED
150
MINIMUM PER NEC:
150.`+
SERVICE SIZE:
Nate: This Load Call is based on the information provided by the builder. The recommended service size will be installed leaving sufficient'usage for future homeowner.
DO NOT SCALE
TERRAIN -
ELEVAMON
METER MAIN COMBO
150AMP NEMA3R OR 200AMP NEMA 3R
WIRE SCHEDULE
I
TO POWER CO- TRANSFORMER
2
M4 RARE COPPER
3
2/0 SER AL ( FOR I SDAMP)
OR
4M SER (FOR 200AMP) AL PER NEC
TO POWER CO.
TRANSFORMER
BY UTILITY COI
INTERSYSTEM BOUNDING
TERMINATION AS PER NEC 250.94
BOND TO FOUNDATION STEEL AS PER NEC 250.52(3)
i
RISER DIAGRAM
N.T.S.
154A.RH REVISEVS/l/2620
Ronald
Maronda Homes LLC of' FL
Imo' Rayf
21#
Mechanical one
CFC1430061
CAC1820196
Cry #3����
15V-( /jde �
Digitally signed
CAJason,- ,byJason James
r, _ -.Date:, 20 2
s 1.11.03