Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PROJECT INFORMATION
!' � 54A -F- wrightsoft Manual S Compliance Report Job: 1Date: 06118I2029 Entire House By: BORKOSKY RON HAUPT r Project Information For: 154A- FP020029, FOCUS HOMES 7905 SEBASTIM RD., FORT PIERCE, FL 34951 Cooling Equipment Design Conditions Outdoor design DB: 90.4°F Sensible gain: 21416 Btuh Entering coil DB: 75.0°F Outdoor design WB: 77.4°F Latentgain: 4536 Btuh Entering coil WB: 62.5°F Indoor design DB: 75.07 Total gain: 25952 Btuh Indoor RH: 50% Estimated airflow: 800 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer: Grandair Model: WCH6304GKB+WAXL364A Actual airflow: 800 cfm Sensible capacity: 21316 Btuh 100% of load Latent capacity: 7884 Btuh 174% of load Total capacity: 29200 Btuh, 113%of'load SHR: 73% floatipg • • Design Conditions Outdoor design DB: 41.0°F Heat loss: 21941 Btuh Entering coil DB: 70.0°F Indoor design DB: 70.0 °F Manufacturer's Performance Data at Actual Design Conditions Equipmenttype: SpIitASHP Manufacturer: Grandair Actual airflow: 800 do Outputcapacity: 0 Btuh Supplemental heat required: 21941 Model: WCH6304GKB+WAXL364A 0%of load Btuh Backup equipment type: Elec strip Manufacturer: n/a Model: n/a+n/a Actual airflow: 800 cfm Output capacity: 0 kW 0% of load Temp. rise: • Meets all requirements ofACCA Manual S. -F- wrightsoft a•�a.mne.�.,r,eo„q..., RigH-Sule®Uriversa1201919.0:95RSU06033 immorselDesktopUNanJ-PSL\154A-FP020029.rup Calc=MJ8 Frort Door faoes: N 0 °F Capacity balance: 65 °F Economic balance: 0 °F 2021-Jun-1811:53:11 Page 1 -7 - - wrightsoftl Building Analysis Entire House RON HAUPT License: CAC058534 Project• • For: 154A-.FP020029, FOCUS HOMES 7905 SEBASTIAN RD., FORT PIERCE, FL34951 Job: 154A Date: 0611812021 By: BORKOSKY D- • • • • Location: Indoor: Heating Cooling St Lucie Co Intl, FL US Indoor temperature (°F) 70 75 Elevation: 26 ft Design TD (°F) 29 15, Latitude: 286N Relative humidity (% 30 50 Outdoor: Heating Cooling Moisture difference (grAb) 2.4 56.9 Dry bulb (°F) 41 90 Infiltration: Daily range, (OF) - 15 ( L ) Method Simplified Wet bulb (OF) - Wind speed (mph) ' 15.0 77 7.5 Construction quality Fireplaces Average 0 Heating Component Btuh/ftz Btuh Walls 3.5 4965Glazing 13.6 1813Doors 132.1 11.3 633Ceilings 0.9 1435Floors 9.9 7049 Infiltration 1:8 2902 13.2 Ducts 3144 14.3, Piping 0 0 Humidification 0 0 Mentilation 0 0 Adjustments 0 Total 1 1 21941 100.0 Floors "0, in w• - - , Com onent Btuh/ftz Btuh %of load Walls 2.3 3327 15.5 Glazing 39.5 5253 24.5 Doors 11.4 640 3.0 Ceilings 1.7 2612 12.2 Floors 0 0 0 Infiltration 0.5 811 3.8 Ducts 3402 15.9 Mentilation 0 0 Internal gains 5370 25.1 Blower 0 0 Adjustments 0 Total 21416 100.0 Latent Cooling Load =4536 Btuh Overall U-value = 0.141 Btu h/ft- °F Data entries checked. Glazing %,emngs Gains -i p- wrigtrtsoft- 2021-Ju-1811:53:11 �` •� »ram• •�-,�ryw RigR-Sdte®Uriversal 201919.0.15 RSUC6033 Page 1 j0M ...immorse%Desktop%bnJ-PSLN54A-FP020029.np Calc=MJ8 FrorlDoorfaces-- N Pro ect .Summa Job: 154A wrightsOfts ry Date: 061181202i Entire House By: BORKOSKY RON HAUPT Pro•ect Information For. 154A- FP020029 .FOCUS HOMES 7905 SEBASTIM RD., FORT PIERCE, FL34951 Notes: 154A Design Information Weather: St Lucie Co,lntl, FL, US Winter Design Conditions Summer Design Conditions Outside db 41 or Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 29 °F Design TD 15 `F Daily.range L Relative humidity 50 % Moisture difference 57 grAb Heating Summary . Structure 18797 Btuh Ducts 3144 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 BtUh Equipmentload 21941 Btuh Infiltration Method Construction quality Fireplaces Simplified Average 0 Area (ft2) Fle ti 1546 Co 1finng. \blume (fr) 14378 14378 Air changgesthour 0.38 0.20 Equiv.AVF (din) 91 48 Heating Equipment Summary Make Grandair Trade HEAT PUMP Model WCH6304GKB AHRI ref 202476,854 Sensible. Cooling Equipment Load Sizing Structure 18014 Btuh Ducts 3402 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturers data n Rate/swingg. multipptier 0.95 Equipmentsensibleload .20431 Btuh Latent Cooling Equipment Load Sizing Structure 3652 Btuh Ducts 884 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 4536 Btuh Equipment Total Load (Sen+Lat) 24967 Btuh Req. total capacity at 0.73 SHR 2.3 ton Cooling Equipment Summary Make Grandair Trade HEAT PUMP Cond WCH6304GKB Coil WAXL364A AHRI ref 202476854 Efficiency 9 HSPF Efficiency 12.5 EER, 16 SEER Heating input Sensible cooling 21316 Btuh Heating output 0 Btuh @470F Latentcooling 7884 Btuh Temperature rise 0 OF Total cooling 29200 Btuh Actual airflow 800 ,elm Actual airflow 800 cfm. Air flow factor 0.036 cfmBtuh Airflowfactor 0.037 dim/Btuh Static pressure .0.50 in H2O Static pressure, 0.50 in H2O ,Space thermostat Load sensible heat ratio 0.83 Capacity balance point = 65 OF Backup: n/a n/a Input = 0 kW, Output = 0 Btuh, 100 AFUE BoWitalic values have been manuaW overridden Calculations approved byACCA to meet all requirements of Manual 'J 8th Ed. C '� wrig(�tsoft" •M•y••�..—,�-a� Rigft-SUte®UriveTsa1201919:0.15_ RSU06033 2021-An-181 3: .-Immorse'lDesktop\WnJ-PSLI154A-FP020029.rup Ca1c=MJ8 FrodDoorfaces: N P 1 T - 1- wrightsoft'. Duct System Summary Entire House License: CAC058534 Job: 164A Date: 0611812021 By: BORKOSKY RON HAUPT i • -ct intormation For: 154A- FP020029, FOCUS HOMES 7905 SEBASTIAN RD., FORT PIERCE, FL 34951 Heating Cooling External static pressure 0:50. in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 ih H2O 0.50 in H2O Supply / return available pressure 0.400 / 0.100 in H2O 0.400 0.1.00 in H2O Lowest friction rate 0.400 iri/100ft 0.400 in/100ft Actual airflow 800 cfm 800 cfm Total effective length (TEL) 125 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR. Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk NOOK c 4487 101 168 0.400 7.0 OxO VIFx 100.0 0 st1 GREATROOM c 3893 81 145 0.400 7.0 Ox0 VIFx 100.0 0 st1 MASTERBDR h 3735 136 118 0.400 6.0 Ox0 VIFx 100.0 0 st1 BDRH2 h 1693 62 49 0.400 5.0 OxO VIFx 1' 0.0 0 st1 LAUNDRY c 1924 30 72 0.400 5.0 Ox0 VIFx 100.0 0 st1 MASTERTIOLET h 2523 92 39 0.400 5.0 OxO VIFx 100.0 0 st1 HALL BATH h 819 30 9 0.400 4.0 O:x 0 VIFx 100.0 0 st1 BDR#3 h 3931 143 72 0.400 7.0 'OxO VIFx 100.0 0 st1 KfrCHEN c 1923 42 72 OAOO 5.0. OxO MFx 100.0 0 st1 Rex h 2251 82 56 .OAOO 5.0 Ox0 MFx 100.0 0 st1 �- — ----- ----- .Supply Trunk:Detail Table' Name Trunk Type Htg (cfm) Clg (cfm) Design FR Meloc (fpm) Diam (in) H x W (in) Duct Material Trunk st1 PeakAVF 800 800 0.400 748 14.0 0 x 0 VinlFlx Return Branch Detail Table Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloo (fp m) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Mat Trunk rb1 Ox0 800 800 25.0 0.400 573 16.0 Ox 0 VIFx BoWfalic values have been manually overridden wrightsoft, 2021-Jun-1811:53:11 RigttSuteOUdversa1201919.0.15RSU06033 Page l �+M ..:immorsel )esktaplManJ- PSL1154A- FP020029.ny Calc= MJ8 Frortboor faces: N 154A RH Ronald Mar_onda Homes LLC of FL SUR q! REVISED 8/1%2020