Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutProject Information-Installation Requirements® -
JamesHardle Complete Measurements
8/23/17
Wolff Residence
Front Elevation
12150. Riverbend Rd, Port St....
FRONT
. BACK .
mow
© 2017 HOVER Inc. All rights reserved. This document and the Images, measurement data, format and contents are the exclusive property of HOVER. HOVER Is the registered trademark of Hover , PROPERTY ID' 363099
Inc. All other brands, products and company names mentioned herein may be trademarks or registered trademarks of their respective holders.
{ WOLFF
HOVERPowered by
Use of this document is subject to HOVER's Terms of Use and is provided "as is." HOVER makes no guarantees, representations or warranties of any kind, express or implied, arising by law or i 14 JULY 2017
otherwise relating to this document or its contents or use, including but not limited to, quality, accuracy, completeness, reliability, or fitness for a particular purpose.
Page 6
® .
j JamesHardle Complete Measurements
8/23/17
Wolff Residence
Right Elevation
"red by HOVER
12150 Riverbend Rd, Port St....
R-IG T
© 2017 HOVER Inc. All rights reserved. This document and the images, measurement data, format and contents are the exclusive property of HOVER. HOVER is the registered trademark of Hover Inc All other brands, products and company names mentioned herein may be trademarks or registered trademarks of their respective holders. PROPERTY ID' 363099
WOLF
Use of this document is subject to HOVER's Terms of Use and is provided "as is." HOVER makes no guarantees, representations or warranties of any kind, express or Implied, arising by law or 14 JULY 2017
otherwise relating to this document or its contents or use, including but not limited to, quality, accuracy, completeness, reliability, or fitness for a particular purpose. I
Page 8
0
JamesHardie Complete Measurements
8/23/17
Wolff Residence
Rear Elevation
Yellow Highlighted Walls To Remain As Is.
12150 Riverbend Rd, Port St....
B yr
© 2017 HOVER Inc. All rights reserved. This document and the images, measurement data, format and contents are the exclusive property of HOVER. HOVER is the registered trademark of Hover PROPERTY ID' 363099
Inc. All other brands, products and company names mentioned herein may be trademarks or registered trademarks of their respective holders. I
WOLFF
Use of this document is subject to HOVER's Terms of Use and is provided "as is." HOVER makes no guarantees, representations or warranties of any kind, express or implied, arising by law or 14 JULY 2017
otherwise relating to this document or its contents or use, Including but not limited to, quality, accuracy, completeness, reliability, or fitness for a particular purpose. i
Page 10
JamesHardle Complete Measurements
8/23/17
Wolff Residence
Left Elevation
12150 Riverbend Rd, Port St....
L
© 2017 HOVER Inc. All rights reserved. This document and the images, measurement data, format and contents are the exclusive property of HOVER. HOVER is the registered trademark of Hover j PROPERTY ID' 363099
Inc. All other brands, products and company names mentioned herein may be trademarks or registered trademarks of their respective holders. j WOLFF
Use of this document Is subject to HOVER's Terms of Use and is provided "as is." HOVER makes no guarantees, representations or warranties of any kind, express or implied, arising by law or ' 14 JULY 2017
otherwise relating to this document or Its contents or use, including but not limited to, quality, accuracy, completeness, reliability, or fitness for a particular purpose. I
Page 12
HardiePlank- 10- fE Lap Siding% JamesHardie
EFFECTIVE SEPTEMBER 2013
INSTALLATION REQUIREMENTS - PRIMED & COLORPLUS11 PRODUCTS visit www.jameshardle.comfor the most recent version.
SELECT CEDARMILL® • SMOOTH • CUSTOM COLONIAL'" SMOOTH • CUSTOM COLONIAL'" ROUGHSAWN
CUSTOM BEADED CEDARMILL® • CUSTOM BEADED SMOOTH • STRAIGHT -EDGE SHINGLE PLANK
IMPORTANT FAILURETO INSTALLAND FINISH THIS PRODUCT IN ACCORDANCE WITH APPLICABLE BUILDING CODES AND JAMES HARDIE WRITTEN
APPLICATION INSTRUCTIONS MAY LEAD TO PERSONAL INJURY, AFFECT SYSTEM PERFORMANCE, VIOLATE LOCAL BUILDING CODES, AND VOID THE
PRODUCT ONLY WARRANTY. BEFORE INSTALLATION, CONFIRM THAT YOU ARE USING THE CORRECT HARDIEZONE'"" PRODUCT INSTRUCTIONS.
INSTALLATION OF HZ100 PRODUCTS OUTSIDE AN HZ101D LOCATION WILL VOID YOUR WARRANTY. TO DETERMINE WHICH HARDIEZONET
APPLIES TO YOUR
VISIT WWW.HARDIEZONE.COM OR CALL 1-866-942-7343
STORAGE & HANDLING:
© CUTTING INSTRUCTIONS
OUTDOORS
1. Position cutting station so that wind will blow dust away from user
and others in working area.
2. Use one of the following methods:
a. Best [. Score and snap
ii. Shears (manual, electric or pneumatic)
b. Better. I. Dust reducing circular saw equipped with a
HardieBlade° saw blade and HERA vacuum extraction
c. Good: I. Dust reducing circular saw with a HardieBlade saw blade
(only use for low to moderate cutting)
INDOORS
1. Cut only using score and snap, or shears (manual, electric or pneumatic).
2. Position cutting station in well -ventilated area
Store flat and keep dry and covered prior
to installation. Installing siding wet or
saturated may result in shrinkage at butt
joints. Carry planks on edge. Protect
edges and comers from breakage. James
Hardie is not responsible for damage
caused by improper storage and handling
of the product.
- NEVER use a power saw indoors
NEVER use a circular saw blade that does not carry the HardieBlade saw blade trademark
NEVER dry sweep — Use wet suppression or HEPA Vacuum
Important Note: For maximum protection (lowest respirable dust production), James Hardie recommends always using "Best" -level cutting methods where feasible.
1p
NIOSH-approved respirators can be used in conjunction with above cutting practices to further reduce dust exposures. Additional exposure information is available
at www.lameshardie.com to help you determine the most appropriate cutting method for your job requirements. If concern still exists about exposure levels or you
do not comply with the above practices, you should always consult a qualified industrial hygienist or contact James Hardie for further information.
scoaaros
®
GENERAL REQUIREMENTS:
• HardiePlank® lap siding can be installed over braced wood or steel studs spaced a maximum of 24" o,c. or directly to minimum 7/16" thick OSB sheathing.
See general fastening requirements. Irregularities in framing and sheathing can mirror through the finished application.
• Information on installing James Hardie products over foam can be located in JH Tech Bulletin 19 at www. jamehardie.com
• A water -resistive barrier is required in accordance with local building code requirements. The water -resistive barrier must be appropriately installed with
penetration and junction flashing in accordance with local building code requirements. James Hardie will assume no responsibility for water infiltration.
James Hardie does manufacture HardieWrap® Weather Barrier, a non -woven non -perforated housewrap', which complies with building code requirements.
• When installing James Hardie products all clearance details in figs. 3-14 must be followed.
• Adjacent finished grade must slope away from the building in accordance with local building codes -
typically a minimum of 6" in the first 10'. Figure 1 t)ouT79 Walt p�wa
• Do not use HardiePlank lap siding in fascia or trim applications. I canstn CAVE r
• Do not install James Hardie products, such that they may remain in contact with standing water. water -resistive barrier let -in bracing
• HardiePlank lap siding may be installed on flat vertical wall applications only. plywood or 2a' o.c. max.
• For larger projects, including commercial and multi -family projects, where the span of the OSB sheathing
T 4
wall is significant in length, the designer and/or architect should take into consideration the
coefficient of thermal expansion and moisture movement of the product in their design.
These values can be found in the Technical Bulletin "Expansion Characteristics of
James Hardie® Siding Products" at www.JamesHardie.com.
• DO NOT use stain, oil/alkyd base paint, or powder coating on James Hardie® Products.
INSTALLATION: JOINTTREATMENT
Figure 2
One or more of the following joint treatment options g
Nail line (If nail
line is not
are required by code (as referenced 2009IRC stud
present place
R703.3.2)
fastener
A. Joint HashingJames Hardie recommended) _...•-
(
between 3/4"
& 1 " from top
B. Caulking' (Caulking is not recommended
resistive /B,„try
of plank)
for ColorPlus for aesthetic reasons as the
barrier of plank
r
Caulking and ColorPlus will weather
differently. For the same reason, flashing
do not caulk nail heads on '
Ha
ColorPlus products.} Hardle
C. "H" jointer cover
Install planks In
moderate contact at butt joints
o N
"° ° water-resisiwe
° barrier
o°o
_Poensure
fastener
° Install a 1 1/4" starter strip to
a consistent plank angle
leave appropriate gap between planks and trim, then caulk."'
Note: Field painting over caulking may produce a sheen difference when compared to the field painted PrimePlus. 'Refer to Caulking section in these instructions.
' For additional information on HardieWrap® Weather Barrier, consult James Hardie at 1-866-4Hardje or www.hardiewrap.com
WARNING: AVOID BREATHING SILICA DUST
James Hardie° products contain respirable crystalline silica, which Is known to the State of California to cause cancer and Is considered by [ARC and NIOSH to be a cause of cancer from some occupational
sources. Breathing excessive amounts of respirable silica dust can also cause a disabling and potentially fatal lung disease called silicosis, and has been linked with other diseases. Some studies suggest
smoking may increase these risks. During installation or handling: (1) work in outdoor areas with ample ventilation; (2) use fiber cement shears for cutting or, wh asi se a [e
and dust -reducing circular saw attached to a HEPA vacuum; (3) warn others in the Immediate area; (4) wear a properly -fitted, NIOSH-approved dust mask or resp r N �n ag or e 1101yS
government regulations and manufacturer insWctions to further limit respirable silica exposures. During clean-up, use HEPA vacuums or wet cleanup methods e s ep. Fo urth lnf r
to our Installation Instructions and Material Safety Data Sheet available at www,jameshardle.com or by calling 1-800-9HARDIE (1-800-942-7343). FAILURE A F UR I D
INSTALLATION INSTRUCTIONS MAY LEAD TO SERIOUS PERSONAL' INJURY OR DEATH. mososas
HS11119-P1/4 6/13
N >om
CLEARANCE AND FLASHING REQUIREMENTS
Figure 3 Figure 4 Figure 5 Figure 6
Roof to Wall Horizontal Flashin4 Kickout Flashing Slabs, Path, Steps to Siding
Figure 7
Deck to Wall
Figure 12
Drip Edge
Z-Flashing _
Mln.'/4"
Do not caulk!
Figure 8
Ground to Siding
Figure 13
Block F
Jjimln4
lred
Iwo, code.
x4"
Figure 9 Figure 10
Gutterto Siding Sheltered Areas
r 'Z Flashing ;
- Min.
Min. Y2"
Figure 14
In Valley/Shingle Extension
in.1 -29:
I
Figure 11
Mortar/Masonry
-Flashing }t
Z-Fft shing
r
i�4 i
FASTENER REQUIREMENTS **
Blind Nailing is the preferred method of installation for HardiePlanke lap siding products. Face nailing should only be used where required by code for high wind
areas and must not be used in conjunction with Blind nailing (Please see JH Tech bulletin 17 for exemption when doing a repair). Pin -backed comers may be
done for aesthetic purposes Only. Pin -backs shall be done with finish nails only, and are not a substitute for blind or face nailing.
BLIND NAILING FACE NAILING
Halls - Wood Framin Nails - Wood Framing
• Siding nail (0.09" shank x 0.221 " HD x 2" long) • 6d (0.113" shank x 0.267" HD x 2" long)
• 11 ga. roofing nail (0.121" shank x 0.371" HD x 1.25" long) • Siding nail (0.09" shank x 0.221" HD x 2" long)
Screws - Steel Framing Screws - Steel Framing
• Ribbed Wafer -head or equivalent (No. 8 x 1 1/4" long x 0.375" HD) Screws must • Ribbed Bugle -head or equivalent (No. 8-18 x 1-5/8" long x
penetrate 3 threads into metal framing. 0.323" HD) Screws must penetrate 3 threads into metal framing.
Nails - Steel Framing Nails - Steel Framing
• ET & F Panelfast7 nails or equivalent (0.10" shank x 0.313" HD x 1-1 /2" long) • ET & F pin or equivalent (0.10" shank x 0.25" HD x 1-1 /2" long)
-atlQ Mls a etdra 'nimum 1/4" into metal framing. Nails must penetrate minimum 1/4" into metal framing.
OSB minimum 77,16" - OSB minimum 7/16"
• 11 ga, roofing nail (0.121 " shank x 0.371 " HD x 1.75" long) • Siding nail (0.09" shank x 0.221 " HD x 1-1/2" long)'
• Ribbed Wafer -head or equivalent (No. 8 x 1 5/8" long x 0.375" HD). 24" �
stud
Stud O.� mex I Figure 15 Figure 16 O.C. max.
_ Minimum overlap 11/4" min.
for Both Face I overlap
/ and Blind Nailing
! Nail Line
t
o / 3/4%1" I _
i Blind Nail I
- --- min. 1 1/4" I a o
overlap =� face nail
i t
i I
i
I
Water Resistive I water -resistive
1 114"min. - Barrier barrier
Ovedap
Laminate sheet to be removed immediately after installation of each course for ColorPlus® products.
' When face nailing to OSB, planks must be no greater than 91/4" wide and fasteners must be 12" o.c. or less.
" Also see General Fastening Requirements; and when considering alternative fastening options refer to James Hardie's Technical Bulletin USTB 17 - Fastening Tips for HardiePlane Lap Siding,
HS11119-P2/4 6/13
GENERAL FASTENING REQUIREMENTS
Fasteners must be corrosion resistant, galvanized, or stainless steel.
Electro-galvanized are acceptable but may exhibit premature corrosion.
James Hardie recommends the use of quality, hot -dipped galvanized nails.
James Hardie is not responsible for the corrosion resistance of fasteners.
Stainless steel fasteners are recommended when installing James Hardie®
products near the ocean, large bodies of water, or in very humid climates.
Manufacturers of ACO and CA preservative -treated wood recommend spacer
materials or other physical barriers to prevent direct contact of ACQ or CA
preservative -treated wood and aluminum products. Fasteners used to attach
HardieTrim Tabs to preservative -treated wood shall be of hot dipped
zinc -coated galvanized steel or stainless steel and in accordance to 2009 IRC
R317.3 or 2009 IBC 2304.9.5.
• Consult applicable product evaluation or listing for correct fasteners type
and placement to achieve specified design wind loads.
• NOTE: Published wind loads may not be applicable to all areas where Local
Building Codes have specific jurisdiction. Consult James Hardie Technical
Services if you are unsure of applicable compliance documentation.
• Drive fasteners perpendicular to siding and framing.
• Fastener heads should fit snug against siding (no air space). (fig. A)
• Do not over -drive nail heads or drive nails at an angle.
• If nail is countersunk, fill nail hole and add a nail. (fig. B)
• For wood framing, under driven nails should be hit flush to the plank with a
hammer (For steel framing, remove and replace nail).
• NOTE: Whenever a structural member is present, HardiePlank should be
fastened with even spacing to the structural member. The tables allowing
direct to OSB or plywood should only be used when traditional framing is
not available.
• Do not use aluminum fasteners, staples, or clipped head nails.
V. mm
PNEUMATIC FASTENING
James Hardie products can be hand nailed or fastened with a pneumatic tool.
Pneumatic fastening is highly recommended. Set air pressure so that the
fastener is driven snug with the surface of the siding. A flush mount
attachment on the pneumatic tool is recommended. This will help control the
depth the nail is driven. If setting the nail depth proves difficult, choose a
setting that under drives the nail. (Drive under driven nails snug with a
smooth faced hammer - Does not apply for installation to steel framing).
Q (J)
snug flush
Figure A
L�_ Rcountersunk,
fill & add nail
Figure B
under drive nails staple
PAINTING
IDO NOT use stain, oil/alkyd base paint, or powder coating on James Hardie®
Products. James Hardie products must be painted within 180 days for primed
product and 90 days for unprimed.100% acrylic topcoats are recommended.
Do not paint when wet. For application rates refer to paint manufacturers
specifications. Back -rolling is recommended if the siding is sprayed.
CUT EDGE TREATMENT
Caulk, paint or prime all field cut edges. James Hardie touch-up kits are
required to touch-up ColorPlus products.
CAULKING
For best results use an Elastomeric Joint Sealant complying with ASTM C920
Grade NS, Class 25 or higher or a Latex Joint Sealant complying with ASTM
C834. Caulking/Sealant must be applied in accordance with the
caulking/sealant manufacturer's written instructions. Note: OSI Quad as well
as some other caulking manufacturers do not allow tooling.
GOLORPLUS� TECHNOLOGY CAULKING TOUCH-UP LAMINATE
• Care should be taken when handling and cutting James Hardie@ ColorPlus@ products. During installation use a wet soft cloth or soft brush to gently wipe off any
residue or construction dust left on the product, then rinse with a garden hose.
• Touch up nicks, scrapes and nail heads using the ColorPlus• Technology touch-up applicator. Touch-up should be used sparingly.
If large areas require touch-up, replace the damaged area with new HardiePlank• lap siding with ColorPlus Technology.
• Laminate sheet must be removed immediately after installation of each course.
Terminate non -factory cut edges into trim where possible, and caulk. Color matched caulks are available from your ColorPlus® product dealer.
Treat all other non -factory cut edges using the ColorPlus Technology edge coaters, available from your ColorPlus product dealer.
Note: James Hardie does not warrant the usage of third party touch-up or paints used as touch-up on James Hardie ColorPlus products.
Problems with appearance or performance arising from use of third party touch-up paints or paints used as touch-up that are not James Hardie touch-up will not be
covered under the James Hardie ColorPlus Limited Finish Warranty.
PAINTING JAMES HARDIE" SIDING AND TRIM PRODUCTS WITH COLORPLUS® TECHNOLOGY
When repainting ColorPlus products, James Hardie recommends the following regarding surface preparation and topcoat application:
• Ensure the surface is clean, dry, and free of any dust, dirt, or mildew
• Repriming is normally not necessary
• 100% acrylic topcoats are recommended
• DO NOT use stain, oiValkyd base paint, or powder coating on James Hardie® Products.
• Apply finish coat in accordance with paint manufacturers written instructions regarding coverage, application methods, and application temperature
• DO NOT caulk nail heads when using ColorPlus products, refer to the ColorPlus touch-up section
HS11119-P3/4 6/13
COVERAGE CHARTIESTIMATING GUIDE
Number of 12' planks, does not include waste
COVERAGE AREA LESS OPENINGS I HARDIEPLAW LAP SIDING WIDTH
SQ
51/4
61/4
71/4
71/2
8
81/4
91/4
91/2
12
(1 SQ =100 sq.ft.)
(exposure) 4
5
6
6114
6 3/4
7
8
81/4
10 3/4
1
25
20
17
16
15
14
13
13
9
2
50
40
33
32
30
29
25
25
19
3
75
60
50
48
44
43
38
38
28
4
100
80
67
64
59
57
50
50
37
5
125
100
83
80
74
71
63
63
47
6
150
120
100
96
89
86
75
75
56
7
175
140
117
112
104
100
88
88
65
8
200
160
133
128
119
114
100
100
74
9
225
180
150
144
133
129
113
113
84
10
250
200
167
160
148
143
125
125
93
11
275
220
183
176
163
157
138
138
102
12
300
240
200
192
178
171
150
150
112
13
325
260
217
208
193
186
163
163
121
14
350
280
233
224
207
200
175
175
130
15
375
300
250
240
222
214
188
188
140
16
400
320
267
256
237
229
.200
200
149
17
425
340
283
272
252
243
213
213
158
18
450
360
300
288
267
257
225
225
167
19
475
380
317
304
281
271
238
238
177
20
500
400
333
320
296
286
250
250
186
This coverage chart is meant as a guide. Actual usage is subject to variables such as building design. James Hardie does not assume responsibility
for over or under ordering of product. .
IRECOGNITION: In accordance with ICC-ES Evaluation Report ESR-2290, HardiePlanke lap siding is recognized as a suitable alternate to that specified in: the 2006,201 International Residential Code for One -
and Two -Family Dwellings, and the 2006, 2009, & 2012 International Building Code,. HardiePlank lap siding is also recognized for application in the following: City of Los Angeles Research Report No. 24862, State of
Florida listing FL#889, Dade County, Florida NOA No. 02-0729.02, U.S. Dept of HUD Materials Release 1263c, Texas Department of Insurance Product Evaluation EC-23, City of New York MEA 223-93-M, and California
DSA PA-019. These documents should also be consulted for additional information concerning the suitability of this product for specific applications.
© 2013 James Hardie Building Products. All rights reserved. Additional Installation Information,
TM, SM, and O denote trademarks or registered trademarks of
James Hardie Technology Limited. ®isaregistered trademark Warranties, and Warnings are available at. "em. JameSHaidle
of James Hardie Technology Limited. www.jameshardie.com
Panelfast is a registered trademark of ET&F Fastening Systems, Inc
HS11119-P4/4 6/13