Loading...
HomeMy WebLinkAboutProject Information-Installation Requirements® - JamesHardle Complete Measurements 8/23/17 Wolff Residence Front Elevation 12150. Riverbend Rd, Port St.... FRONT . BACK . mow © 2017 HOVER Inc. All rights reserved. This document and the Images, measurement data, format and contents are the exclusive property of HOVER. HOVER Is the registered trademark of Hover , PROPERTY ID' 363099 Inc. All other brands, products and company names mentioned herein may be trademarks or registered trademarks of their respective holders. { WOLFF HOVERPowered by Use of this document is subject to HOVER's Terms of Use and is provided "as is." HOVER makes no guarantees, representations or warranties of any kind, express or implied, arising by law or i 14 JULY 2017 otherwise relating to this document or its contents or use, including but not limited to, quality, accuracy, completeness, reliability, or fitness for a particular purpose. Page 6 ® . j JamesHardle Complete Measurements 8/23/17 Wolff Residence Right Elevation "red by HOVER 12150 Riverbend Rd, Port St.... R-IG T © 2017 HOVER Inc. All rights reserved. This document and the images, measurement data, format and contents are the exclusive property of HOVER. HOVER is the registered trademark of Hover Inc All other brands, products and company names mentioned herein may be trademarks or registered trademarks of their respective holders. PROPERTY ID' 363099 WOLF Use of this document is subject to HOVER's Terms of Use and is provided "as is." HOVER makes no guarantees, representations or warranties of any kind, express or Implied, arising by law or 14 JULY 2017 otherwise relating to this document or its contents or use, including but not limited to, quality, accuracy, completeness, reliability, or fitness for a particular purpose. I Page 8 0 JamesHardie Complete Measurements 8/23/17 Wolff Residence Rear Elevation Yellow Highlighted Walls To Remain As Is. 12150 Riverbend Rd, Port St.... B yr © 2017 HOVER Inc. All rights reserved. This document and the images, measurement data, format and contents are the exclusive property of HOVER. HOVER is the registered trademark of Hover PROPERTY ID' 363099 Inc. All other brands, products and company names mentioned herein may be trademarks or registered trademarks of their respective holders. I WOLFF Use of this document is subject to HOVER's Terms of Use and is provided "as is." HOVER makes no guarantees, representations or warranties of any kind, express or implied, arising by law or 14 JULY 2017 otherwise relating to this document or its contents or use, Including but not limited to, quality, accuracy, completeness, reliability, or fitness for a particular purpose. i Page 10 JamesHardle Complete Measurements 8/23/17 Wolff Residence Left Elevation 12150 Riverbend Rd, Port St.... L © 2017 HOVER Inc. All rights reserved. This document and the images, measurement data, format and contents are the exclusive property of HOVER. HOVER is the registered trademark of Hover j PROPERTY ID' 363099 Inc. All other brands, products and company names mentioned herein may be trademarks or registered trademarks of their respective holders. j WOLFF Use of this document Is subject to HOVER's Terms of Use and is provided "as is." HOVER makes no guarantees, representations or warranties of any kind, express or implied, arising by law or ' 14 JULY 2017 otherwise relating to this document or Its contents or use, including but not limited to, quality, accuracy, completeness, reliability, or fitness for a particular purpose. I Page 12 HardiePlank- 10- fE Lap Siding% JamesHardie EFFECTIVE SEPTEMBER 2013 INSTALLATION REQUIREMENTS - PRIMED & COLORPLUS11 PRODUCTS visit www.jameshardle.comfor the most recent version. SELECT CEDARMILL® • SMOOTH • CUSTOM COLONIAL'" SMOOTH • CUSTOM COLONIAL'" ROUGHSAWN CUSTOM BEADED CEDARMILL® • CUSTOM BEADED SMOOTH • STRAIGHT -EDGE SHINGLE PLANK IMPORTANT FAILURETO INSTALLAND FINISH THIS PRODUCT IN ACCORDANCE WITH APPLICABLE BUILDING CODES AND JAMES HARDIE WRITTEN APPLICATION INSTRUCTIONS MAY LEAD TO PERSONAL INJURY, AFFECT SYSTEM PERFORMANCE, VIOLATE LOCAL BUILDING CODES, AND VOID THE PRODUCT ONLY WARRANTY. BEFORE INSTALLATION, CONFIRM THAT YOU ARE USING THE CORRECT HARDIEZONE'"" PRODUCT INSTRUCTIONS. INSTALLATION OF HZ100 PRODUCTS OUTSIDE AN HZ101D LOCATION WILL VOID YOUR WARRANTY. TO DETERMINE WHICH HARDIEZONET APPLIES TO YOUR VISIT WWW.HARDIEZONE.COM OR CALL 1-866-942-7343 STORAGE & HANDLING: © CUTTING INSTRUCTIONS OUTDOORS 1. Position cutting station so that wind will blow dust away from user and others in working area. 2. Use one of the following methods: a. Best [. Score and snap ii. Shears (manual, electric or pneumatic) b. Better. I. Dust reducing circular saw equipped with a HardieBlade° saw blade and HERA vacuum extraction c. Good: I. Dust reducing circular saw with a HardieBlade saw blade (only use for low to moderate cutting) INDOORS 1. Cut only using score and snap, or shears (manual, electric or pneumatic). 2. Position cutting station in well -ventilated area Store flat and keep dry and covered prior to installation. Installing siding wet or saturated may result in shrinkage at butt joints. Carry planks on edge. Protect edges and comers from breakage. James Hardie is not responsible for damage caused by improper storage and handling of the product. - NEVER use a power saw indoors NEVER use a circular saw blade that does not carry the HardieBlade saw blade trademark NEVER dry sweep — Use wet suppression or HEPA Vacuum Important Note: For maximum protection (lowest respirable dust production), James Hardie recommends always using "Best" -level cutting methods where feasible. 1p NIOSH-approved respirators can be used in conjunction with above cutting practices to further reduce dust exposures. Additional exposure information is available at www.lameshardie.com to help you determine the most appropriate cutting method for your job requirements. If concern still exists about exposure levels or you do not comply with the above practices, you should always consult a qualified industrial hygienist or contact James Hardie for further information. scoaaros ® GENERAL REQUIREMENTS: • HardiePlank® lap siding can be installed over braced wood or steel studs spaced a maximum of 24" o,c. or directly to minimum 7/16" thick OSB sheathing. See general fastening requirements. Irregularities in framing and sheathing can mirror through the finished application. • Information on installing James Hardie products over foam can be located in JH Tech Bulletin 19 at www. jamehardie.com • A water -resistive barrier is required in accordance with local building code requirements. The water -resistive barrier must be appropriately installed with penetration and junction flashing in accordance with local building code requirements. James Hardie will assume no responsibility for water infiltration. James Hardie does manufacture HardieWrap® Weather Barrier, a non -woven non -perforated housewrap', which complies with building code requirements. • When installing James Hardie products all clearance details in figs. 3-14 must be followed. • Adjacent finished grade must slope away from the building in accordance with local building codes - typically a minimum of 6" in the first 10'. Figure 1 t)ouT79 Walt p�wa • Do not use HardiePlank lap siding in fascia or trim applications. I canstn CAVE r • Do not install James Hardie products, such that they may remain in contact with standing water. water -resistive barrier let -in bracing • HardiePlank lap siding may be installed on flat vertical wall applications only. plywood or 2a' o.c. max. • For larger projects, including commercial and multi -family projects, where the span of the OSB sheathing T 4 wall is significant in length, the designer and/or architect should take into consideration the coefficient of thermal expansion and moisture movement of the product in their design. These values can be found in the Technical Bulletin "Expansion Characteristics of James Hardie® Siding Products" at www.JamesHardie.com. • DO NOT use stain, oil/alkyd base paint, or powder coating on James Hardie® Products. INSTALLATION: JOINTTREATMENT Figure 2 One or more of the following joint treatment options g Nail line (If nail line is not are required by code (as referenced 2009IRC stud present place R703.3.2) fastener A. Joint HashingJames Hardie recommended) _...•- ( between 3/4" & 1 " from top B. Caulking' (Caulking is not recommended resistive /B,„try of plank) for ColorPlus for aesthetic reasons as the barrier of plank r Caulking and ColorPlus will weather differently. For the same reason, flashing do not caulk nail heads on ' Ha ColorPlus products.} Hardle C. "H" jointer cover Install planks In moderate contact at butt joints o N "° ° water-resisiwe ° barrier o°o _Poensure fastener ° Install a 1 1/4" starter strip to a consistent plank angle leave appropriate gap between planks and trim, then caulk."' Note: Field painting over caulking may produce a sheen difference when compared to the field painted PrimePlus. 'Refer to Caulking section in these instructions. ' For additional information on HardieWrap® Weather Barrier, consult James Hardie at 1-866-4Hardje or www.hardiewrap.com WARNING: AVOID BREATHING SILICA DUST James Hardie° products contain respirable crystalline silica, which Is known to the State of California to cause cancer and Is considered by [ARC and NIOSH to be a cause of cancer from some occupational sources. Breathing excessive amounts of respirable silica dust can also cause a disabling and potentially fatal lung disease called silicosis, and has been linked with other diseases. Some studies suggest smoking may increase these risks. During installation or handling: (1) work in outdoor areas with ample ventilation; (2) use fiber cement shears for cutting or, wh asi se a [e and dust -reducing circular saw attached to a HEPA vacuum; (3) warn others in the Immediate area; (4) wear a properly -fitted, NIOSH-approved dust mask or resp r N �n ag or e 1101yS government regulations and manufacturer insWctions to further limit respirable silica exposures. During clean-up, use HEPA vacuums or wet cleanup methods e s ep. Fo urth lnf r to our Installation Instructions and Material Safety Data Sheet available at www,jameshardle.com or by calling 1-800-9HARDIE (1-800-942-7343). FAILURE A F UR I D INSTALLATION INSTRUCTIONS MAY LEAD TO SERIOUS PERSONAL' INJURY OR DEATH. mososas HS11119-P1/4 6/13 N >om CLEARANCE AND FLASHING REQUIREMENTS Figure 3 Figure 4 Figure 5 Figure 6 Roof to Wall Horizontal Flashin4 Kickout Flashing Slabs, Path, Steps to Siding Figure 7 Deck to Wall Figure 12 Drip Edge Z-Flashing _ Mln.'/4" Do not caulk! Figure 8 Ground to Siding Figure 13 Block F Jjimln4 lred Iwo, code. x4" Figure 9 Figure 10 Gutterto Siding Sheltered Areas r 'Z Flashing ; - Min. Min. Y2" Figure 14 In Valley/Shingle Extension in.1 -29: I Figure 11 Mortar/Masonry -Flashing }t Z-Fft shing r i�4 i FASTENER REQUIREMENTS ** Blind Nailing is the preferred method of installation for HardiePlanke lap siding products. Face nailing should only be used where required by code for high wind areas and must not be used in conjunction with Blind nailing (Please see JH Tech bulletin 17 for exemption when doing a repair). Pin -backed comers may be done for aesthetic purposes Only. Pin -backs shall be done with finish nails only, and are not a substitute for blind or face nailing. BLIND NAILING FACE NAILING Halls - Wood Framin Nails - Wood Framing • Siding nail (0.09" shank x 0.221 " HD x 2" long) • 6d (0.113" shank x 0.267" HD x 2" long) • 11 ga. roofing nail (0.121" shank x 0.371" HD x 1.25" long) • Siding nail (0.09" shank x 0.221" HD x 2" long) Screws - Steel Framing Screws - Steel Framing • Ribbed Wafer -head or equivalent (No. 8 x 1 1/4" long x 0.375" HD) Screws must • Ribbed Bugle -head or equivalent (No. 8-18 x 1-5/8" long x penetrate 3 threads into metal framing. 0.323" HD) Screws must penetrate 3 threads into metal framing. Nails - Steel Framing Nails - Steel Framing • ET & F Panelfast7 nails or equivalent (0.10" shank x 0.313" HD x 1-1 /2" long) • ET & F pin or equivalent (0.10" shank x 0.25" HD x 1-1 /2" long) -atlQ Mls a etdra 'nimum 1/4" into metal framing. Nails must penetrate minimum 1/4" into metal framing. OSB minimum 77,16" - OSB minimum 7/16" • 11 ga, roofing nail (0.121 " shank x 0.371 " HD x 1.75" long) • Siding nail (0.09" shank x 0.221 " HD x 1-1/2" long)' • Ribbed Wafer -head or equivalent (No. 8 x 1 5/8" long x 0.375" HD). 24" � stud Stud O.� mex I Figure 15 Figure 16 O.C. max. _ Minimum overlap 11/4" min. for Both Face I overlap / and Blind Nailing ! Nail Line t o / 3/4%1" I _ i Blind Nail I - --- min. 1 1/4" I a o overlap =� face nail i t i I i I Water Resistive I water -resistive 1 114"min. - Barrier barrier Ovedap Laminate sheet to be removed immediately after installation of each course for ColorPlus® products. ' When face nailing to OSB, planks must be no greater than 91/4" wide and fasteners must be 12" o.c. or less. " Also see General Fastening Requirements; and when considering alternative fastening options refer to James Hardie's Technical Bulletin USTB 17 - Fastening Tips for HardiePlane Lap Siding, HS11119-P2/4 6/13 GENERAL FASTENING REQUIREMENTS Fasteners must be corrosion resistant, galvanized, or stainless steel. Electro-galvanized are acceptable but may exhibit premature corrosion. James Hardie recommends the use of quality, hot -dipped galvanized nails. James Hardie is not responsible for the corrosion resistance of fasteners. Stainless steel fasteners are recommended when installing James Hardie® products near the ocean, large bodies of water, or in very humid climates. Manufacturers of ACO and CA preservative -treated wood recommend spacer materials or other physical barriers to prevent direct contact of ACQ or CA preservative -treated wood and aluminum products. Fasteners used to attach HardieTrim Tabs to preservative -treated wood shall be of hot dipped zinc -coated galvanized steel or stainless steel and in accordance to 2009 IRC R317.3 or 2009 IBC 2304.9.5. • Consult applicable product evaluation or listing for correct fasteners type and placement to achieve specified design wind loads. • NOTE: Published wind loads may not be applicable to all areas where Local Building Codes have specific jurisdiction. Consult James Hardie Technical Services if you are unsure of applicable compliance documentation. • Drive fasteners perpendicular to siding and framing. • Fastener heads should fit snug against siding (no air space). (fig. A) • Do not over -drive nail heads or drive nails at an angle. • If nail is countersunk, fill nail hole and add a nail. (fig. B) • For wood framing, under driven nails should be hit flush to the plank with a hammer (For steel framing, remove and replace nail). • NOTE: Whenever a structural member is present, HardiePlank should be fastened with even spacing to the structural member. The tables allowing direct to OSB or plywood should only be used when traditional framing is not available. • Do not use aluminum fasteners, staples, or clipped head nails. V. mm PNEUMATIC FASTENING James Hardie products can be hand nailed or fastened with a pneumatic tool. Pneumatic fastening is highly recommended. Set air pressure so that the fastener is driven snug with the surface of the siding. A flush mount attachment on the pneumatic tool is recommended. This will help control the depth the nail is driven. If setting the nail depth proves difficult, choose a setting that under drives the nail. (Drive under driven nails snug with a smooth faced hammer - Does not apply for installation to steel framing). Q (J) snug flush Figure A L�_ Rcountersunk, fill & add nail Figure B under drive nails staple PAINTING IDO NOT use stain, oil/alkyd base paint, or powder coating on James Hardie® Products. James Hardie products must be painted within 180 days for primed product and 90 days for unprimed.100% acrylic topcoats are recommended. Do not paint when wet. For application rates refer to paint manufacturers specifications. Back -rolling is recommended if the siding is sprayed. CUT EDGE TREATMENT Caulk, paint or prime all field cut edges. James Hardie touch-up kits are required to touch-up ColorPlus products. CAULKING For best results use an Elastomeric Joint Sealant complying with ASTM C920 Grade NS, Class 25 or higher or a Latex Joint Sealant complying with ASTM C834. Caulking/Sealant must be applied in accordance with the caulking/sealant manufacturer's written instructions. Note: OSI Quad as well as some other caulking manufacturers do not allow tooling. GOLORPLUS� TECHNOLOGY CAULKING TOUCH-UP LAMINATE • Care should be taken when handling and cutting James Hardie@ ColorPlus@ products. During installation use a wet soft cloth or soft brush to gently wipe off any residue or construction dust left on the product, then rinse with a garden hose. • Touch up nicks, scrapes and nail heads using the ColorPlus• Technology touch-up applicator. Touch-up should be used sparingly. If large areas require touch-up, replace the damaged area with new HardiePlank• lap siding with ColorPlus Technology. • Laminate sheet must be removed immediately after installation of each course. Terminate non -factory cut edges into trim where possible, and caulk. Color matched caulks are available from your ColorPlus® product dealer. Treat all other non -factory cut edges using the ColorPlus Technology edge coaters, available from your ColorPlus product dealer. Note: James Hardie does not warrant the usage of third party touch-up or paints used as touch-up on James Hardie ColorPlus products. Problems with appearance or performance arising from use of third party touch-up paints or paints used as touch-up that are not James Hardie touch-up will not be covered under the James Hardie ColorPlus Limited Finish Warranty. PAINTING JAMES HARDIE" SIDING AND TRIM PRODUCTS WITH COLORPLUS® TECHNOLOGY When repainting ColorPlus products, James Hardie recommends the following regarding surface preparation and topcoat application: • Ensure the surface is clean, dry, and free of any dust, dirt, or mildew • Repriming is normally not necessary • 100% acrylic topcoats are recommended • DO NOT use stain, oiValkyd base paint, or powder coating on James Hardie® Products. • Apply finish coat in accordance with paint manufacturers written instructions regarding coverage, application methods, and application temperature • DO NOT caulk nail heads when using ColorPlus products, refer to the ColorPlus touch-up section HS11119-P3/4 6/13 COVERAGE CHARTIESTIMATING GUIDE Number of 12' planks, does not include waste COVERAGE AREA LESS OPENINGS I HARDIEPLAW LAP SIDING WIDTH SQ 51/4 61/4 71/4 71/2 8 81/4 91/4 91/2 12 (1 SQ =100 sq.ft.) (exposure) 4 5 6 6114 6 3/4 7 8 81/4 10 3/4 1 25 20 17 16 15 14 13 13 9 2 50 40 33 32 30 29 25 25 19 3 75 60 50 48 44 43 38 38 28 4 100 80 67 64 59 57 50 50 37 5 125 100 83 80 74 71 63 63 47 6 150 120 100 96 89 86 75 75 56 7 175 140 117 112 104 100 88 88 65 8 200 160 133 128 119 114 100 100 74 9 225 180 150 144 133 129 113 113 84 10 250 200 167 160 148 143 125 125 93 11 275 220 183 176 163 157 138 138 102 12 300 240 200 192 178 171 150 150 112 13 325 260 217 208 193 186 163 163 121 14 350 280 233 224 207 200 175 175 130 15 375 300 250 240 222 214 188 188 140 16 400 320 267 256 237 229 .200 200 149 17 425 340 283 272 252 243 213 213 158 18 450 360 300 288 267 257 225 225 167 19 475 380 317 304 281 271 238 238 177 20 500 400 333 320 296 286 250 250 186 This coverage chart is meant as a guide. Actual usage is subject to variables such as building design. James Hardie does not assume responsibility for over or under ordering of product. . IRECOGNITION: In accordance with ICC-ES Evaluation Report ESR-2290, HardiePlanke lap siding is recognized as a suitable alternate to that specified in: the 2006,201 International Residential Code for One - and Two -Family Dwellings, and the 2006, 2009, & 2012 International Building Code,. HardiePlank lap siding is also recognized for application in the following: City of Los Angeles Research Report No. 24862, State of Florida listing FL#889, Dade County, Florida NOA No. 02-0729.02, U.S. Dept of HUD Materials Release 1263c, Texas Department of Insurance Product Evaluation EC-23, City of New York MEA 223-93-M, and California DSA PA-019. These documents should also be consulted for additional information concerning the suitability of this product for specific applications. © 2013 James Hardie Building Products. All rights reserved. Additional Installation Information, TM, SM, and O denote trademarks or registered trademarks of James Hardie Technology Limited. ®isaregistered trademark Warranties, and Warnings are available at. "em. JameSHaidle of James Hardie Technology Limited. www.jameshardie.com Panelfast is a registered trademark of ET&F Fastening Systems, Inc HS11119-P4/4 6/13