Product Approval Menu > Product or Application Search > Application List > Application Detail
FL # FL17824
Application Type New
Code Version ,,,'��g 3f3 2014
ApplicatioWMDFORC
CON N Approved
REVIEWED B
.DATE
Comment si'L.�NS AND PE,Tow
BI �$
Archived UR NO INSPECTION WILL BE ,4IADE, f
Product Manufacturer United Roofing
Address/Phone/Email Finches Ferry Road
Eutaw, AL 35462
THESE PLANS AND ALL PROPOSED v(6G3) 248-2101 EXt 227
ARE SUBJECT TO ANY CORRECTION�r)ortfol,io@gardner-gibson.com
REQUIRED BY FIELD INSPECTORS THAT
MAY BE NECESSARY IN ORDER TO
COMPLY WITH ALL APPLICAB6R 6005S:
Authorized Signature DON PORTFOLIO
dportfolio@gardner-gibson.com
Technical Representative CONCEALED FASTENERS OR ATTACHMENTS
Address/Phone/Email ARE THE RESPONSIBILITY OF THE
CONTRACTOR OF RECORD
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Roofing
Underlayments
Evaluation Report from a Florida R
Florida Professional Engineer
r Evaluation Report - Hardcopy I
FILE COPY
3/9/2017 10:06 PA
C iurlud DW ming �,uuu Vll1111C uu�a.iiwww.u�uuauw,uug.vi Sr yii yi_ayy_u«.uayn,yua uay •, ., �..
Florida Enginee or Architect Name who developed Zachary R. Priest
the Evaluation :ntity
rt
Florida License PE-74021
Quality AssuranUL LLC
Quality Assurance Contract Expiration Date 12/31/2020
Validated By Locke Bowden
F Validation Checklist - Hardcop,.
Certificate of Independence FL17824 RO COI GGI15001 201,
Skin.pdf
Referenced Standard and Year (of Standard)
Equivalence of Product Standards.-
Certified B
Sections f om the Code
1507.2.3
1507.2.8
1507.4.5.1
1507.4.5.2
1507.5.3
1507.5.3.2
1507.7.3
1507.7.3.2
1507.8.3
1507.8.3.2
1507.9.3
1507.9.3.2
1507.9.5
1518.4
�I�i 1A
dui
3H 0 YTUN-121aQ,-"?"7'h -HT 3H
fit+ ar'i()TWAT$f -
ct Approval Method
Submitted
Validated
Pending FBC Approval
Approved
Method 2 Option B
06/26/2015
06/26/2015
07/05/2015
08/20/2015
2 of 3 1 3/9/2017 10:06 P)
..ua iuu liwiuii,r' %,vuc viuunc uups:iiwww.iivnuilowiu►ng.ur�pripr_app_u�►.aspx: para►ii—wilt
a
Summary of Products '
FL #
Model, Number or Name
Description
17824.1
Gator Skin
Steep -slope roofing t
ASTM D 226, Type I
IV.
Limits of.Use
Installation Instrui
Approved for use in HVHZ: Yes
FL17824 RO II GG
Gator Skin.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Zachary
Design Pressure: N/A
Created by Indepen(
Other: See evaluation. report for limits of use.
Evaluation Reports
FL17824 RO AE G(
Gator Skin.pdf
Created by Indepen(
FBack Next
n(
in,
:ti
1.`
R
ler
III
er
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-4
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in respo
electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any question:
Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must
they have one. The emails provided may be used for official communication with the licensee. However email ad(
supply a personal address, please provide the Department with an email address which can be made available to th
Chapter 455, F.S., please click here .
Product Approval Accepts:
'� ECI1ELIf ',i.'.yA
Credit. Card
Safe
3 of 3 3/9/2017 10:06 Pl
`rECHNICA►L,
121
RVICEs, LLC
Certificate of AuthorizaSon No. 29824
17520 Edinburgh Drive
Tampa, FL 33647
(813) 480-3421
EVALUATION REPORT
I FLORIDA BUILDING CODE 5TH EDITION (2014)
Manufacturer:
UNITED ROOFING MANUFACTURING CO., INC. Issued June 26, 2015
P` BOX 30
Eutaw, AL 35462
p)
(20 372-3394
httd://www.unitedroofing.com/
Distribution:
Eutaw, AL
Quality Assurance:
U I LLC (QUA9625)
SCOPE
I
Category:
Roofing
Subcategory:
Underlayments
Code Sections:
1567.2.3, 1507.2.8, 1507.4.5.1, 1507.4.5.2, 1507.5.3, 1507.5.3.2, 1507.7.3, 1507.7.3.2,
15p7;8.3, 1507.8.3.2, T1507.8, 1507.9.3, 1507.9.3.2, 1507.9.5, 1518.4
Properties:
P ysical properties
REFERENCES
Entity
I Report No. Standard Year
PRI Construction Materials Technologies
(TST5878) GGI-132-02-01 ASTM D 226 2006
ASTM D 4869 2005e1
PRODUCT DESCRIPTION
Gator Skin
A mechanically attached, woven polypropylene underlayment used as an alternative to
4STM D 226, Type I and Type II and ASTM D 4869 Type II or Type IV, roofing
lunderlayments
APPLICATION INSTRUCTIONS
Deck Type: The roof deck shall be constructed of closely fitted, solid sheathing for new or existing
construction. Sheathing shall be installed in accordance with FBC requirements. Roof
decks shall have no more than 1/8" gap at abutting joints. Minimum 19/32" plywood for
new construction or minimum 15/32" plywood for existing construction in the HVHZ only.
Min. slope: Min. 2:12 and in accordance with the FBC; For slopes less than 4:12, the underlayment
must be half -lapped over the underlying course.
Attachment (Non-HVHZ): Underlayment shall be attached in accordance with the FBC requirements and in
Iaccordance with the manufacturers installation instructions. The underlayment is
installed starting at the eave, with the length of the roll parallel to the eave with the
printed side facing up. All head laps shall be installed to shed water from the deck and
side laps shall be staggered between successive courses.
Attachment (HVHZ): Underlayment shall be attached in accordance with RAS 115, RAS 130, or RAS 133 and
in accordance with the manufacturer's installation instructions. The underlayment is
installed starting at the eave, -with the length of the roll parallel to the eave with the
printed side facing up. All head laps shall be installed to shed water from the deck and
side laps shall be staggered between successive courses.
Allowable roof coverings: Asphalt shingles, metal roof panels and shingles, slate shingles, wood shakes and
shingles
GG115001 FL17824 Page 1 of 2
This evaluation report is1provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
.._ M.. 1h. a,. a
R E E K l
TECHNICAL SERVICES, LLC
LIMITATIONS
UNITED ROOFING MANUFACTURING CO., INC.
Gator Skin
1) Fire Classification is not within the scope of this evaluation.
2) Wind uplift resistance is not within the scope of this evaluation.
3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published
application instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
4) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck
shall be checked for protrusion arid corrected prior to underlayment application.
5) The underlayment may be used as described in other current FBC product approval documents.
6) Roof coverings shall not be adhered directly to the underlayment. Roof coverings shall be mechanically
fastened through the underlayment to the roof deck.
7) The underlayment shall be exposed on the roof deck for a maximum 30 days unless otherwise stated.
8) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E..' have demonstrated compliance with the Florida Building
Code 5th Edition (2014) as evidenced in the referenced documents submitted by the named manufacturer.
♦`%%�RY 'R,I P����i
`�♦`%%P G E N S '
No 74021
� r
• • X r
:5 STATE OF .'
C?
E�♦♦♦♦
CERTIFICATION OF INDEPENDENCE
Zachary R. Priest, P.E.
Florida Registration No. 74021
Organization No. ANE9641
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this
evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product.
END OF REPORT
GG115001 FL17824 Page 2 of 2
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shdll notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not