Loading...
HomeMy WebLinkAboutEvaluation Report71. Specialty Structural EnglneaL=rinq . CBUCK, Inc. Certificate of Authorization #8064 Evaluation Report Metal Roof Assembly Manufacturer: Extreme Metal Fabricators, LLC. 2160 SW Poma Drive Palm City, FL 34990 (772) 872-8034 for Florida Product Approval # FL 17022.1 R2 Florida Building Code Sth Edition (2014) Per Rule 61G20=3 Method: 1- D Category: Roofing ; Sub - Category: Metal Roofing , Product: 5-V Crimp Roof Panel Material: Steel Panel Thickness: 26 gauge. Panel Width: 24", . Support: Wood Deck Prepared by: James L. Buckner, P.E., SECB Florida Professional Engineer # 31242 Florida Evaluation ANE ID. 1§16 'Project Manager: Youry Demosthenes Report No. 15-176-5V-S6W-ER (Revises 14-166-5V-S6W-ER) Date: 6 / 27 / 15 Contents: Evaluation Report Pages 1-7 Digitally signed by James L. Buckner, P.E. Electronically signed and sealed document shall comply with the provisions of FAC Ru 61G15-2 ```�titllllfl///�, %rENSF' * ' No 31242 LUZ: �,�'• STATE OF 441� 1///ll1111 � -J 2015.07.01 11:03:27-04'00' MUCK, Inc. . - FL #: FL 17022.1 R2 Date: 6 / 27 / 15 c UCr=nq1neL=r1Mq Page Report No.: 2 - 76-5V-S6W-ER Spsclalty Structural Engineeringl- Manufacturer: Extreme Metal Fabricators, LLC. Product Name: 5-V Crimp Product Category: Roofing Product Sub -Category Metal Roofing CBUCK; Inc. Certificate of Authorization #8064 Compliance Method: State Product Approval Rule 61G20-3.005 (1) (d) Product/System 5-V Crimp Roof Panel, 26 gauge steel, 24" wide panel mechanically attached to Description: Wood Deck with screws. Product Assembly as Refer to Page 4 of this report for product assembly components/materials & Evaluated: standards: 1. Roof Panel 2. Fasteners 3. Underlaymerit 4. Insulation Board (Optional) Support: Type: Wood Deck (Design of support and its attachment to support framing is outside the scope of this evaluation.) Description: • 15/32" or greater plywood, • or Wood plank (min. specific gravity of 0.42) Slope: Minimum slope shall be in compliance with FBC Chapter 15 Section 1507.4.2, applicable code sections and in accordance with manufacturer's recommendations. Performance: Wind Uplift Resistance: • Design Uplift Pressure (ASD): Refer to Table A (Refer to "Table A" attachment details herein) - It JIM - � "i FL M FL 17022.1 R2 Date: 6 / 27 / 15 Report No.: 15-176-5V-S6W-ER Page 3 of 7 ISpecialty Structural Engineering DUCK, Inc. Certificate of Authorization #8064 Performance The product described herein has demonstrated'compliance with: Standards: • UL580-06 —Test for Uplift Resistance of Roof Assemblies • UL 1897-04 - Uplift test for roof covering systems • TAS 125-03 —Standard Requirements for Metal Roofing Systems Code Compliance: The product described herein has demonstrated compliance with Florida Building Code 5th Edition (2014), Section 1504.3.2. Evaluation Report This product evaluation is limited to compliance with the structural Scope: requirements of the Florida Building Code, as related to the scope section to Florida Product Approval Rule 61G20-3.001. Limitations and • Scope of "Limitations and Conditions of Use:' for this evaluation: Conditions of. Use: This evaluation report for "Optional Statewide Approval' contains technical documentation, specifications and installation method(s) which include "Limitations and Conditions of Use" throughout the report in accordance with Rule 61G20-3.005. Per Rule 61G20-3.004, the Florida Building Commission is the authority to approve products under "Optional Statewide Approval'. • Option for aoolication outside "Limitations and Conditions of Use" Rule 61G20-3.005(1)(e) allows engineering analysis for "project specific approval by the local authorities having jurisdiction in accordance with the alternate methods and materials authorized in the Code". Any modification of the product as evaluated 'in this report and approved by the Florida Building Commission is outside the scope of this evaluation and will be the responsibility of others. • Design of support system is outside the scope of this report. • Fire Classification is outside the scope of Rule 61G20-3, and is therefore not included in this evaluation. • This evaluation report does not evaluate the use of this product for use in the High Velocity Hurricane Zone code section. (Dade & Broward Counties) Quality Assurance: The manufacturer has demonstrated compliance of roof panel products in accordance with the Florida Building Code, and Rule 61G20-3.005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity through Keystone 'Certifications, Inc. (FBC Organization ID# QUA 1824). , FL #: FL 17022.1 R2 Date: 6 / 27 / 15 EM UC Ezn � �nrl Page 4 of 7 Report No.: 6-5V-S6W-ER Speclaltiy Structural Engineerinq CBUCK, Inc. Certificate of Authorization #18064 Components/Materials (by Manufacturer): Roof Panel: Material: Thickness: Panel Widths: Rib Height: Yield Strength: Corrosion Resistance: Fastener: FASTENER 1 Type: Size: Corrosion Resistance: Standard: 5-V Crimp Steel 26 gauge (min.) 24" (max.) Coverage 5/8„ 40 ksi min. Per FBC Section 1507.4.3 Used for Attachment Method 1 Hex Washer Head Wood Screw #9 x 1-1/2" (min.) Per FBC Section 1506.6 and 1507.4.4 Per ANSI/ASME B18.6.1 FASTENER 2 Used for Attachment Method 2 & 3 Type: Hex Washer Head Wood Screw Size: #10 x 1-1/2" (min.) Corrosion Resistance: Per FBC Section 1506.6 and 1507.4.4 Standard: Per ANSI/ASME B18.6.1 Components& Materials: Underlayment: (by Others) Material and application shall be in compliance with FBC Section 1507.4.5.1 and 1507.4.5.2, applicable codes and in accordance with manufacturer's recommendations. Insulation (Optional): Type: Thickness: Properties: Density: Or Compressive Strength: Rigid Insulation Board 3" (max.) 2.25 pcf (Ibs/ftt3) min. 20 psi min. Insulation Notes: • Rigid Insulation shall meet minimum density OR compressive strength. • Insulation shall comply with FBC Section 1508. When insulation is incorporated, fastener length shall conform to penetrate thru bottom of support a minimum of 3/16". FL #: FL 17022.1 R2 Date: 6 / 27 / 15 Report No.: 15-176-5V-S6W-ER Em-dneeto rIn Page 5 of 7 SpeclaN-j Sfirucfiural Engineering CBUCK, Inc. Certificate of Authorization ##8064 Installation: Installation Method: (Refer to "TABLE A" below and drawings at the end of this evaluation report.) ■ Fastener Spacing: Refer to "TABLE A" Below (attached to the tops of the V's for a total of 3 screws acrosss the width of the panel.) + Row Spacing: Refer to "TABLE A" Below (along the length of the panel) ■ Minimum fastener penetration thru bottom of support, 3/16". ■ For panel construction at the end of panels, refer to manufacturer's instructions and any site specific design. TABLE "A" ALLOWABLE LOADS METHOD 1: METHOD 2: METHOD 3: Design Pressure (ASD)*: - 86 PSF - 93.5 PSF -101 PSF Row Spacing: 16" o.c. 16" o.c. 8" o.c. Fastener Spacing (across panel width): 12" o.c. 12" o.c. 12" o.c. Fastener Size: #9 #10 #10 * Allowable design pressure(s) for allowable stress design (ASD) with a margin of safety of 2 to 1. Install the 5-V Crimp roof panel assembly in compliance with the installation method listed in this report and applicable code sections of FBC 5th Edition (2014). The installation method described herein is in accordance with the scope of this evaluation report. Refer to -manufacturer's installation. instructions as a supplemental guide for attachment. Referenced Data: 1. UL 580-06 & UL 1897-04— Uplift Test By Architectural Testing, Inc. -West Palm Beach, FL (FBC Organization #TST ID: 1527) Report No.: D5893.01-450-18, Date: 05-/ 02 /14 2. TAS 125 — Uplift Test By Architectural'Testing, Inc. - West Palm Beach, FL (FBC Organization #TST ID: 1527) Report No.: D5893.02-450-18, Date: 07 / 22 /14 3. Quality Assurance Keystone Certifications, Inc. (FBC Organization IN QUA 1824) Extreme Metal Fabricators, Inc: Licensee #974 4. Certification of Independence By James L. Buckner, P.E. @ CBUCK Engineering (FBC Organization # ANE 1916) CUC�� FL #: FL 17022.1 R2 Date: 6 / 27 / 15 Report No.: 15-176-5V-S6W-ER Page 6 of 7 Specialty Structural Engineering CBUCK, Inc. Certificate of Authorization #8064 i 5/8 " 7 Installation Method Extreme Metal Fabricators, LLC. 5-V Crimp (26 gauge steel) Roof Panel attached to Wood Deck Drawings 24" Maximum Net Coverage Panel Profile Nodnel 1r am I Nominal 120 o.a I Pesie ais NO x 1-1rZ Mn. or #10 x 1-112" Mln. per 7h6le W H8XVWWHOad5MW Pane! Overlap W as across the Panel Wdth Rdwto Tattle W for Spadn9Along Parcel Len81h Dedc - ISW or Grader Plywood, or - Wood Plant Typical Assembly Profile View (Typical Fastening Pattern Across Width - Interior) • — FL #: FL 17022.1 R2 Date: 6 / 27 / 15 CBUCK Engineering Page Report No.: 1 -1776-5V-S6W-ER Speclalftj Structural Englneerinq CBUCK, Inc. Certificate of Authorization #8064 Installation Method Extreme Metal Fabricators, LLC. 5-V Crimp (26 gauge steel) Roof Panel attached to Wood Deck -15/32" or greater Plywood, or - Wood plank Typical Roof Assembly Isometric View (Optional) Rigid Insulation Board per Page 4 of this report TABLE "A" ALLOWABLE LOADS METHOD 1: METHOD 2: METHOD 3: Design Pressure (ASD)*: - 86 PSF - 93.5 PSF -101 PSF Row Spacing: 16" o.c. 16" o.c. 8" o.c. Fastener Spacing (across panel width): 12" o.c. 12" o.c. 12" ox. Fastener Size: #9 #10 #10 * Allowable design pressure(s) for allowable stress design (ASD) with a margin of safety of 2 to 1.