Loading...
HomeMy WebLinkAboutRevisioni OFFICE USE ONLY: l q DATE FILED: a 6 E ( D REVISION FEE: ' Oo PERMIT # 1708-0293 RECEIPT # PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE "ItN' FORT PIERCE, FL 34982-5652 (772) 462.1553 pe"�7/tj '96'?OIB St �t' 9 0 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION rah, enF LOCATION/SITE ADDRESS: 8335 Calumet Court, Port Saint Lucie DETAILED DESCRIPTION OF PROJECT REVISIONS: Change Layout of Pool Enclosure CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: BUSINESS NAME: Coastal Aluminum Construction, Inc. QUALIFIERS NAME: William Dramble ADDRESS: 496 S Market Avenue CITY: Fort Pierce STATE: FL PHONE (DAYTIME): (772)468-0288 OWNER/BUILDER INFORMATION: NAME: Imran Malik ADDRESS: 8335 Calumet Court CITY: Port Saint Lucie PHONE (DAYTIME: STATE: ARCHITECT/ENGINEER INFORMATION: NAME: Aluminum Screen Design ADDRESS: 4401 Vineland Road Ste A6 CITY: Orlando PHONE (DAYTIME): (407)734-1470 STATE: ST. LUCIE CO CERT. #: 20128 FAX: FL FAX: ZIP: 34982 ZIP: 34986 FL ZIP: _ FAX: (888)923-8181 SLCCC: 9123109 Revised 06130117 REVISION 32811 25 Construction; .Inc. 496 S. Market Avenue Fort Pierce,. FL 34982 In the event of a conflict in member sizes shown on the Plans and the generAi notes, tha contractor must utilize the More auingaflf member slza raqulromont% .� fA ,x 2,43 t� fv ?V.2 2' 2. 1 L- ALUMINUM SCREEN DESIGN 1" GUTTER STRAP IS ATTACHED TO GUTTER WITH #10 1" & INTO FASCIA WITH #10 2" PER STRAP 24" O.C. MAX 4" FROM EACH UPRIGHT BEAM TO FASCIA SEE GENERAL NOTES & DESIGN STANDARD FOR ADDITIONAL SMB BEAM IS ATTACHED TO GUTTER W/ 2X2X1/8" ANGLE & (4) #10 1" PER SIDE F O / 708 O ST. LUCIF L-, TN-- RUILDEVO _ SION REVIEWOR COIAPL y JuAliL i PLANS AND PERMI MUST E KEPT ON JOB \ OR NO INSPECTION WILL E 'ODE. (3) # 10 2" SMS, PLACE WASHER UNDER SCREW IN GUSSET CORNER ,. . ARE THE RESPONSIBILITY C.; i CONTRUWF RECORD • �W NOTES • 1. GUSSET DIMENSIONS ARE MINIMUM X 8" ON BOTH SIDE OF BEAM, MAYBE Q INTERNAL OR EXTERNAL 2. AS BEAM SIZE CHANGES ADD OR SUBTRACT TO MAINTAIN A 1-1/4" O.C. SCREW SPACING W/ (10) SCREWS 3. GUSSET LENGTH REMAINS CONSTANT, WIDTHS CHANGE TO MATCH BEAM SIZE BEAM TO WALL • • • THESE PLANS AND ALL PROPOSE WORK 2X2 IS ATTACHED TO sTRucTuRE WARE SUBJECT TO ANY CORRECTIONS • • • 4" X 1/4" TAPCONS (910 4" IF TO WOOPEQUIRED BY FIELD INSPECTORS THAT STRUCTURE) 6" FROM ENDS 24" O.C. • ��M./nA�'Y''Bpp''E NECESSARY IN ORDER TO • • • 2X2 ANGLE IS ATTACHED TC�HE+NF�Y WITHAL APPUCABLE C ODES. WITH (2) #10 1" & INTO BLOCK WITH • 2-1/4" X 1/4" TAPCON • • • • • • -1/4 O.C. SMS 1-1/4 O.C. AlaZAACREENDESIGN.COM DESIGN STATEMENT MICHAEL THOMPSON METAL IS .046 THICKNESS OR GREATER, ALLOY IS 6005-T5 4401 VINELAND ROAD �CREENDESIGN ALL TAPCONS SHALL PROVIDE MINIMUM OF 1 1/8" CONCRETE EMBEDMENT DEPTH SUITE A6 M THIS STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE TO MEET THE REQUIREMENTS OF THE 2017 PHON_ E:.407-734-1470 FLORIDA BUILDING CODE FOR OPEN AND SEMI -OPEN STRUCTURES AND SHALL WITH STAND ULTIMATE WIND SPEEDS OF 150 MPH ORLANDO, FL 32811 (FOR 3 SECOND GUSTS) NOMINAL SPEED 117 MPH UP TO A 15FT ROOF HEIGHT, FACTOR OF 1.0, AND EXPOSURE C, RISK CATEGORY 1. 47509 FAX: 407-734-1790 CONTRACTOR SHALL FIELD VERIFY ALL PLANS DIMENSIONS PRIOR TO MATERIAL PURCHASE, FABRICATION AND CONSTRUCTION - CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY SHOULD SITE CONDITIONS DIFFER FROM CONSTRUCTION PLANS A#3 093 0 C p"m f N n 'w" ff