HomeMy WebLinkAboutEnergy Efficiency CodeFORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: LITEPLO RESIDENCE Builder Name: Street: 2106 NW LAUREL OAK LANE Permit Office: City, State, Zip: PLAM CITY, FL, Permit Number. Owner: Jurisdiction: Design Location: FL, West Palm Beach County:: MARTIN COUNTY (Florida Climate Zone 2 ) 1. New construction or existing Addition 9. Wall Types (441.0 sqft.) Insulation Area ' 2. Single family or multiple family Single-family a. Frame - Wood, Exterior R=19.0 225.00 ft2 3. Number of units, if multiple family 1 b. Concrete Block - Ext Insul, Exterior R=4.1 216.00 ft2 c. N/A R= ft2 4. Number of Bedrooms Bedrms In Addition) 0(0) d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (273.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 273.00 ft2 6. Conditioned floor area above grade (ft2) 273 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(136.0 sqft.) Description Area 11. Ducts a. Sup: Attic, Ret: Attic, AH: ADDITION R ft2 6 54 a. U-Factor: Dbl, U=0.30 136.00 ft2 SHGC: SHGC=0.19 b. U-Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 23.8 SEER:14.50 c. U-Factor: N/A ft2 SHGC: d. U-Factor: N/A ft2 13. Heating systems 'a. kBtu/hr Efficiency SHGC: Electric Strip Heat 17.0 COPA.00 Area Weighted Average Overhang Depth: 12.000 ft. Area Weighted Average SHGC: 0.190 14. Hot water systems - None required 8. Floor Types (273.0 sqft.) Insulation Area a. Cap: N/A a. Slab -On -Grade Edge Insulation R=0.0 273.00 ft2 b. Conservation features EF: 0.000 b. N/A R= ft2 c. N/A R= ft2 15. Credits CF, Pstat Glass/Floor Area: 0.498 Total Proposed Modified Loads: 12.73 PASS Total Baseline Loads: 12.77 I hereby certify that the plans and specifications covered by Review of the plans and ZflB S7,g1A this calculation are in compliance with the Florida Energy specifications covered by this �y a g,, p �A%' Code. calculation indicates compliance yRi' .,,, �''�� '_ '���.� with the Florida Energy Code. ti rR,p�•' '==f%�.••';•3�p PREPARED Y: DATE: - - Before construction is completed this building will be inspected for r! -- ' '' '""' �� 14 compliance with Section 553.908 I hereby certify that this building, as desi ned, is in compliance Florida Statutes. * ,� � with the Florida Energy Code. Cpb WE, OWNER/AGE T BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory=sealed in accordance with R403.2.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 'Llopyy 7/31/2017 11:21 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 f FORM .R405--2014 PROJECT Title: Building Type: LITEPLO RESIDENCE Bedrooms: 0 User! Address Type: Street Address Owner. Conditioned Area: 273 Lot # . # of Units: 1 Total Stories: 1' . Block/Subl)Msion: Builder Name: Worst Cate: No PlatBook: Permit Office: Rotate Angle: 0 Street 2106 NW LAUREL OA Jurisdiction: Cross Ventilation: No County: MARTIN COUNTY Family Type: Single-family Whole House Fan: No City, State, Zip: PLAN CITY, New/Existing: Addition FL, - Comment: CLIMATE Design I Location MCC' Design Temp TMY Site Int.Design Temp Heatin • - Design Daily Temp Zone 97.5-% 2.5 % . Winter Summer Degree Days Moisture Range - FL, West Palm :Beach FL_WEST_PALM_BEAC 2 44 90 70.. 75 316 60 Medium BLOCKS, , Number,, Name Area • Volume 1 AHU 1 273 2457 SPACES Number. Name Area Volume Kitchen = Occupants Bedrooms fnfil ID Finished Cooled Heated 1 ADDITION iION 273 2457 - No 1 1 Yes Yes Yes FLOORS # Floor Type Space PerimeterR-Value Area Tile Wood Carpet .1 Slab -On -Grade Edge Insulatio ADDITION 74 ft 0 273 fN 1 0 .. 0 ROOF Type Roof Gable Roof- 'Solar SA Emitt Emitt . Deck Pitch ;r _ - - Materials. Area Area Color Absor. Tested Tested Insul., (deg) 1 Gable or shed Bariel file 296'ft2 $6 #2 Medium 0.6 140 0.9 No 0 22.6 i ATTIC '; # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 273 ftz N N - i - CEILING # Ceiling Type Space _ R-Value Ins Type Area Framing Free Truss Type 1 Under Attic (Vented) ADDITION 30 Blown 273 ftz 0.11' Wood 7/31/20171:1:21 AM EnergyGauge®USA- Flakes 2014 Section R405.4.I. Compliant Software Page 2 of 4 d FORM R405-2014 b WALLS Adjacent _ Cavity Width Height Sheathing Framing Solar Spaceype ue Et n Et n Area- ue Below o 1 $E 2 NW 3 SE - Exterior Frame -Wood ADDITION. 1.9 : ` 25 9 225.6 ft 0.23 0.5 Exterior Concrete Block - Ext insLADDITION 4.1 12 9 108.0 ftz 0 0 0.5 Exterior Concrete Block - Ext InsL ADDITION 4.1 12 9 108.0 ftz 0 '0 0.5 j 0 0 0 WINDOWS Orientation shown is the•entered, Proposed orientation. / �/ # Wall Omt ID Frame.. . Panes Overhang - NFRC lJ Factor..SHGC Area Depth Separation Int Shade Screening 1 SE 1 Vinyl Low=E Double Yes . 0.3 0.19 136.0 ft2 12 ft 0 in 11 ft4 in Drapes/blinds" None INFILTRATION # Scope Method SLA, CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) 0004 286.6 15.74 -29.6 .2762 7 . HEATING SYSTEM # System Type Subtype. Efficiency. Capacity Block , _ Ducts 1 Electric Strip Heat None COP:1 . 17 kBtu/hr 1 sys#1 COOLING SYSTEM # System. Type Subtype _ Efficiency Capacity Air Flow - SHR Block Ducts, . 1 Central Unit None SEER: 14:523.8 kBtu/hr 714 cfm, 0.85 1 sys#1 SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF . - ft2. DUCTS . V # Supply — Location R-Value Area — Return — Air CFM 25 CFM25 HVAC # Location, Area Leakage Type: Handler TOT OUT QN RLF Heat Cool 1- Attic. 16 54 ftz . Attic, - 1 W Default Leakage ADDITION ,'(Default) (Default) 1 1 7/31/201711:21 AM, EnergyGauge@-USA- FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4 FORM R4n5-7f)14 u TEMPERATURES Programable Thermostat: Y Ceiling Fans: Coolingan HeatinEX Jan Feb Feb Mar Mar f A r APr f Ma MayJun Jun Jul Jul [Xj Aug j Aug Se SeP [ j Oct [ ]Oct Nov Nov H Dec HDec Ventin [[ Jan Feb X X Mar LX A r [ Ma Jun Jul E ] Au Se [X] Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 7/31/201711:21 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: LITEPLO RESIDENCE Builder Name: Street: 2106 NW LAUREL OAK LANE Permit Office: City, State, Zip: PLAM CITE, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, West Palm Beach COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air -permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop, down stairs or knee wall doors to unconditioned attic spaces. shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door Jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists, are insulated and include an air barrier. Floors (including above -garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall. be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on, installation readily conforms to available space shall extend behind piping and wiring. Showerltub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed. behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. - Fireplace An air barrier shall be, installed on fireplace -walls. Fireplaces shall have gasketed doors 7/31 /2017 11:21 AM EnergyGauge® USA = FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 ' ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* _ 100 ' The lower the EnergyPerformance Index, the more efficient the home. ,f . 2106 NW LAUREL OAK LANE, PLAM CITY, FL, 1. New construction or existing Addition 9. Wall Types Insulation Area = 2. Single family or multiple family Single-family a. Frame - Wood, Exterior R=19.0 225.00 ffz 3. Number of units, if multiple family b. Concrete Block - Ext Insul, Exterior 1 R=4.1 216.00 ftz it c. N/A R= ftz j; 4. Number of Bedrooms; 0(0) d. N/A R= ftz ' 5. Is this a worst case? No 10. Ceiling Types Insulation Area Conditioned a. Under Attic (Vented) R=30.0 273.00 ftz 6. floor area (ftz) 273 b. N/A R= ftz 1 7. Windows`* Description Area c. NIA R= z ft a. U-Factor. 11=0. 136.00 ft z 1.1. Ducts R ftz SHGC: SHGC=0.19 � SH a. Sup: Attic, Ret: Attic, AH: ADDITION 6 54 b. U-Factor: N/A ftz SHGC: 12. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ftz a. Central Unit 23.8 SEER:14.50. R SHGC: d. U-Factor: N/A ftz I SHGC: 13. Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 12.000 ft. a. Electric Strip Heat 17.0 COP:1.00 Area Weighted Average SHGC; 0.190 8. Floor Types Insulation Area 14. Hot water systems - None required a. Slab -On -Grade Edge Insulation R=0.0 273.00 ftz a. Cap: N/A b. NIA R= ftz EF: c. NIA R= b. Conservation features ft= j e 15. Credits CF, Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based.on installed Code compli nt . tures. Builder Signature: Date: g �� Address of New Home-,,2 0.D nQ kf9 �\ � LV-\ City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a. Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 7/311201711:21 AM EnergyGauge@ USA-'FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1