SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for
use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with
the 5th Edition (2014) Florida Building Code sections noted herein.
DESCRIPTION: 3Mm 2-Component Foam Roof Tile Adhesive AH-160
LABELING: Labeling shall be in accordance with the requirements the Accredited. Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the
referenced Quality Assurance documentation changes. Trinity IERD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 9.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCAANE1983
The facsimile seal appearing was authorized by Robert Nieminen,
P.E. on 06/10/2015. This does not serve as an electronically signed
document. Signed, sealed hardcoples have been transmitted to the
Product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. Exterior Research & Design, LLC. d/b/a Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial interest
in any company manufacturing or distributing products it evaluates.
2. Exterior Research & Design, LLC. d/b/a Trinity I ERD is not owned, operated or controlled by any company manufacturing or
distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor .will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity[ ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
��
M Re epy
\NTINITYIERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Roof Tile Adhesives
Compliance Statement: 3MW 2-Component Foam Roof Tile Adhesive AH-160, as produced by 3M Company, has demonstrated
compliance with the Florida Building Code through testing in accordance with the Standards set forth herein. Compliance is
subject to the Installation Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Sections Property
Standard Year
1505.1 External Fire Classification
ASTM E108 2007
1711.2.1 Wind
SSTD 11 1997
3. REFERENCES:
Enfiiy Examination
Reference Date
ERD (TST 6049) SSTD 11
P39740.02.12 02/20/2012
ERD (TST 6049) SSTD 11
P39740.11.13-R1 01/02/2015
]CC -ES (EVL2396) IBC Compliance
ESR-1709 12/01/2014
ITS (TST 1585) ASTM E108
301646522SAT-001_Rev. 1 12/23/2014
Miami -Dade (CER 1592) HVHZ compliance
14-0805.01 09/04/2014
PRI (TST 5878) SSTD 11
ECM-001-02-01 09/21/2001
PRI (TST 5878) SSTD 11
PFI-006-02-01 05/09/2005
PRI (TST 5878) SSTD 11
PFI-006-02-02 05/09/2005
PRI (TST 5878) TA5101
PFI-007-02-01 10/11/2005
PRI (TST 5878) SSTD 11
PFI-008-02-04 02/21/2006
PRI (TST 5878) SSTD 11
PFI-009-02-03 02/21/2006
PRI (TST 5878) SSTD 11
PFPI-010-02-01 12/07/2006
PRI (TST 5878) SSTD it
PFPI-011-02-01 12/07/2006
PRI (TST 5878) SSTD 11
PFPI-012-02-01 12/07/2006
PRI (TST 5878) SSTD 11
PFPI-013-02-01 12/07/2006
PRI (TST 5878) SSTD it
PFPI-014-02-01 12/07/2006
PRI (TST 5878) TAS 101
ECM-003-02-01 06/13/2008
PRI (TST 5878) TAS 101
ECM-004-02-01 06/13/2008
PRI (TST 5878) TAS 101
ECM-005-02-01 06/13/2008
PRI (TST 5878) TAS 101
ECM-006-02-01 06/13/2008
PRI (TST 5878) TAS 101
ECM-007-02-01 06/13/2008
PRI (TST 5878) TAS 101
ECM-008-02-01 06/13/2008
U L LLC (QUA 9625) Quality Assurance
Service Confirmation Exp.06/05/2018
4. PRODUCT DESCRIPTION:
4.1 3M'"' 2-Component Foam Roof Tile Adhesive AH-160 is a two -component expanding polyurethane roof tile adhesive that is
mixed and dispensed from a dispensing system provided by 3M Company. The components are available in refillable
tanks or disposable cylinders (AH-160 PROPAK®).
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity] ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record
for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design
guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Concrete and clay tiles, having a current Florida Statewide Product Approval or approved on a local -level by the AHJ,
adhered using 3M' 2-Component Foam Roof Tile Adhesive AH-160, maintain their respective roof fire classifications.
Refer to FBC 1505.2, Exception 2.
5.4 3M'" 2-Component Foam Roof Tile Adhesive AH-160 can be used with flat, low and high profile tiles or any rigid,
discontinuous roof assembly having a current Florida Statewide Product Approval or approved on a local -level by the AHJ.
5.5 Minimum underlayment shall be per FRSA/TRI April 2012 (04-12) or having a current Florida Statewide Product Approval
or approved on a local -level by the AHJ for use with 3M1"
2-Component Foam Roof Tile Adhesive AH-160.
Exterior Research and Design, I.I.C. Evaluation Report 02768.03.06-RS
Certificate of Authorization #9503 FL6332-RS
Revision 5: 06/10/2015
Page 2 of 9
QOTFuNITYIERD
5.6 Field tiles using 3M— 2-Component Foam Roof Tile Adhesive AH-160 are limited to projects having an Aerodynamic Uplift
Moment (M.), determined in accordance with FBC 1609.5.3 or Tables 2A and 213 of FRSA/TRI April 2012 (04-12), not
greater than the following Allowable Overturning Moment values. Refer to Section 10 and 3M Company published
installation instructions for Adhesive Paddy Placement details.
TABLE 1: FIELD TILES IN 3W 2-COMPONENT FOAM ROOF TILE ADHESIVE AH-160
ALLOWABLE OVERTURNING MOM ENT'PERFORMANCE DATA;
2 To I MARGIN OF SAFE(YALREADYAPPUED FOR INDEPENDENT (S&GLEOR CONTINUOUS'PADDY), PLACEMENT .
4 TO 1 MARGIN OF SAFETYALREADYAPPLIED FOR INTERDEPENDENT (TWO PADDY) PLACEMENT
Tile
Adhesive Paddy Placement
Allowable
Overturning Moment
Type
Profile
(ft-lbf)
Independent; Single Paddy, Medium (20-inch, ^30 gram)
60
Clay or
Flat
Independent; Single Paddy, Large (WO -inch, -45 gram)
112
Interdependent; Two Paddy (4x4-inch on underlayment, 2x4-inch
54
Concrete
at tile overlap)
Independent; Single Paddy, Medium (20-inch, "30 gram)
39
Clay or
Low/ Medium
Independent; Single Paddy, Large (2x10-inch, -54 gram)
67
Interdependent; Two Paddy (4x4-inch on underlayment, 2x4-inch
Concrete
at tile overlap)
58
Clay
High
Independent; Single Paddy, Large (2x10-inch, -45 gram)
134
Independent; Single Paddy, Medium (20-inch, -30 gram)
65
Clay or
High
Independent; Single Paddy, Large (WO -inch, -63 gram)
109
Interdependent; Two Paddy (44-inch on underlayment, W-inch
40
Concrete
at tile overlap)
Clay
Two Piece Barrel
2x10-inch x "35 gram for pans; 2 @ 1x10-inch x -17 gram for cap
147
Concrete
Two Piece Barrel
2x10-inch x -35 gram for pans; 2 @ WO -inch x -17 gram for cap
107
Clay
Cap atop 2x stringer
Independent: Continuous Paddy ("'34 gram/ft)
135
Concrete
Cap atop 2x stringer
Independent: Continuous Paddy (- 34 gram/ft)
116
Clay
Cap atop 2x stringer
Interdependent:
105
Head: One (1) #10 x 2%" screw; Overlap: I x 6 inch (-10.5 gram)
Concrete
Cap atop 2x stringer
Interdependent:
76
Head: One (1) #10 x 2%" screw; Overlap: 1 x 6 inch (-10.5 gram)
5.6.1 Data in Table 1 relates to installation over a '30/90' underlayment system, as detailed in the FRSA/TRI April 2012 (04-12).
Alternate underlayment systems include those having a current Florida Statewide Product Approval and/or approved on
a local -level by the AHJ specifically for use with 3MT" 2-Component Foam Roof Tile Adhesive AH-160.
5.6.2 Tile roof systems using tile types or profiles other than those listed above acquiring acceptance for use with 3MW 2-
Component Foam Roof Tile Adhesive AH-160 shall be tested in accordance with SSTD 11 or TAS 101. For the
interdependent two -paddy method, an additional 2-to-1 margin above that specified in SSTD 11 or TAS 101 shall be
applied in determining the 'allowable overturning moment'.
Exterior Research and Design, I.I.C. Evaluation Report 02768.03.06-RS
Certificate ofAuthorization #9503 FL6332-RS
Revision 5: 06/10/2015
Page 3 of 9
TTRINITYIERD
5.7 Hip and ridge tiles using 3MT" 2-Component Foam Roof Tile Adhesive AH-160 are limited to projects having hip/ridge design
pressure requirements, determined in accordance with Table 1A of FRSA/TRI April 2012 (04-12), not greater than the
following values. Refer to 3M Company published installation instructions for Adhesive Paddy Placement details.
TABLE 2:,HIP & RIDGE TILES IN 3MT"" 2-COMPONENT FOAM ROOF TILE ADHESIVE AH-160,
ALLOWABLE OPLIFT.RESISTANCE PERFORMANCE DATA -
- - - 2 TO 1 MARGIN OF SAFETYALREADYAPPUED FOR INDEPENDENT CONTINUOUS PADDY/ PIACEMENT • '
4 To I MARGIN OF SAFETYALREADYAPPLIED FOR INTERDEPENDENTPLACEMENT
Allowable
Tile
Substrate
Attachment Method
Design Pressure
(psf)
Clay
2x PT ridge board
Independent: Continuous Paddy (-34 gram/ft)
116
Concrete
2x PT ridge board
Independent: Continuous Paddy (- 34 gram/ft)
107
Interdependent: Head: One (1) #10 x 2Y2" screw;
90
Clay
2x PT ridge board
Overlap:1 x 6 inch (-10.5 gram)
Interdependent: Head: One (1) #10 x 2Y." screw;
56
Concrete
2x PT ridge board
Overlap: 1 x 6 inch (-10.5 gram)
Clay or
Hip & Ridge Channel Metal (FBC FL5374):
Independent: Continuous Paddy (^34 gram/ft)
169
Concrete
galvanized only
Clay or
Trim Lock- (FBC FL5374): aluminum,
Independent: Continuous Paddy (^34 gram/ft)
173
Concrete
galvanized, Galvalume® or stainless steel
Clay or
Trim Lock- Plus (FBC FL5374): aluminum,
Independent: Continuous Paddy (� 34 gram/ft)
178
Concrete
galvanized, Galvalume® or stainless steel
6. INSTALLATION:
6.1 3MT" 2-Component Foam Roof Tile Adhesive AH-160 and the tile roof assembly shall be installed in accordance with
FRSA/TRI April 2012 (04-12) and 3M Company published installation instructions, subject to the limitations outlined in
Section 5.
• 6.2 Hip and ridge boards or hip/ridge metal shall be installed in accordance with the FRSA/TRI April 2012 (04-12). Proprietary
hip and ridge metal shall be installed in accordance with the manufacturer's Florida Product Approval.
6.3 Installation shall be performed by applicators who hold a valid Qualified Applicator Card presented by 3M Company.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
8. MANUFACTURING PLANTS:
Contact the manufacturer or the named CIA entity for information on plants covered under Rule 61G20-3 QA requirements.
9. QUALITY ASSURANCE ENTITY:
UL LLC-QUA9625; (414) 248-6409; Karen.buchmann@us.ul.com
Exterior Research and Design, I.I.C. Evaluation Report 02768.03.06-115
Certificate of Authorization #9503 FL6332-RS
Revision 5: 06/10/2015
Page 4 of 9
10. PADDY PLACEMENT DETAILS (FROM 3M PUBLISHED LITERATURE):
10.1 Independent, Medium Paddy:
Nail through plastic cement Paddy (Beneath Tile)
(when required)
Underlayment °
1 o
7in. 2in.
Battens optional °
Eave Course /
0
0
10 in.
Fascia
2 in
Eava Closure
Flat/Low Pro
ffleTile
I'll,NTINITYIERD
Nail through plastic cement
(when required)
Paddy (Beneath Tile)
Underlayment \\ I
Medium Profile Tile
lastic ce
Nail through pflment
(when required)
Paddy (Beneath Tile)
o
(Underlayment
o
7 in.
2 in.
Battens optional
0
Eave Course
Fascia
Weephole
10in.2in.
Eaveclosure
Drip edge
High Profile Tile
Exterior Research and Design, I.I.C. Evaluation Report 02768.03.06-RS
Certificate of Authorization #9503 FL6332-R5
Revision 5: 06/10/2015
Page 5 of 9
.2 Independent, Large Paddy:
Nail through plastic cement Paddy (Beneath Tile)
(when required)
Underlayment °
0
10
Battens optional °
Eave Course
0
° 10in.
Fascia
2 in
Eave Closuro
Flat/Low Pra
Exterior Research and Design, I.I.C.
Certificate of Authorization #9503
fileTile
VNTINITYIERD
Nail through plastic cement
(when required)
Underlayment r�
10 in.x2
2 in.wide y
Battens optional
il
Medium Profile Tile
Nall through plasticce
(when required) Paddy (Beneath Tile)
Underlayment o
o
10 in.x
2 in.wide
Battens
optional o
Eave Course Fascia
Weephole
10 in. 2 in.
Eave closure
Drip edge
High ProfileT)le
Paddy (Beneath Tile)
�L Eave Closure
Fascia
Evaluation Report 02768.03.06-RS
FL6332-RS
Revision 5: 06/10/2015
Page 6 of 9
10.3 Interdependent, Two Paddy:
Nail through plastic cement
(when required)
Battens optional °
o
Single
on top
x4in. /
Single padd
under til
ddy
layment
,�%'
�' 2 x 4 in.
Nin.
2 i
Flat/Low Profile Tile
Exterior Resear&and Design, I.I.C.
Certificate of Authorization 89503
(between tiles)
Paddy (under tile)
(-)0
V TRINITY I ERD
Nail through plastic cement Single paddy under tile
(when required)
Paddy (between tiles)
Battens Paddy (under tile)
(optional
Single paddy
.w�on top of tie
�4x4in. 2x4in.
Single paddy on
undarlaymont
10 in. 2 in.
Eave Closure
Eave Course Fascia
Medium ProfileTile
Nail through plast)cce
Single paddy under tile
(when required)
Paddy (between tiles)
Battens °
optional °
Paddy (under tile)
Single paddy
on undarlaymont
4 x4 in.
Single 2x4in
paddy on
top of tile
Eave Course
Fascia
Weephole
10 in. 2 in.
Eave closure
Drip edge
High Profile rile
Evaluation Report 02768.03.06-RS
FL6332-RS
Revision 5: 06/10/2015
Page 7 of 9
r
10.4 Two Piece Barrel (Cap & Pan) Tile:
1) Place enough adhesive to achieve 65 to 701
in cordoct`1N)th the pan tile.
2) Tern Covers upside down. Place adhesive
12 in. to t inch In from outside edge of cover Ifle.,
.Install cover tilo.
Ensure 20 to 26 eq. in. contact aroa on
cacti side of Dover 010. e
IUndetlayment
Enve d
(matter
Steep
- ---- Fascia Board--`J
Remove top Portion of the ease course,covertile. Abut to second course of
pan tiles. Ensure save end of pan and cover tiles areflush at eave line.
TWo Piece Barrel - High Profile Tile
10.5 Hip and Ridge (independent placement):
A bead of 3M- 2Cangronont Poem Rod Tde Adhesive AH-160 rney be
appi'ed shove the rie ,fie sodas on both sides of the hip/ddge bead or
gaNanaed meW hams to pmvide... thublaeft.
Exterior Research and Design, LLC.
Certificate of Authorization #9503
To aaach. Hpiddge tin. a bud of 3M"
Adhesive AF4160 nW be apoled domt to da
QOTP'uN1TYjERD
To aaacb Wddge tin, a bud of 3M^ 2.0 mp em Poem Rod Tie
Adhesive AH.160 may be applied Wong the full length of the We ecdudhg 2
bxAnon the eaveand ofthe V..
Evaluation Report 02768.03.06-RS
FL6332-RS
Revision 5: 06/10/2015
Page 8of9
10.6 Hip and Ridge (interdependent placement):
- END OF EVALUATION REPORT -
Exterior Research and Design, I.I.C.
Certificate of Authorization #9503
Q0TP'uN1TYjERD
Evaluation Report 02768.03.06-RS
FL6332-RS
Revision 5: 06/10/2015
Page 9 of 9