HomeMy WebLinkAboutReview-CommentsPlanning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL. 34982 Phone:(772)462-2172 Fax:(772)462-6443 PROPERTY INFORMATION Address: 2016 Laurel Oak Ln City / State / Zip: Palm City., FI 34990 Parcel #: 4425-605-0041-000/3 Zoning: PUD APPLICATION INFORMATION Permit Number: 1708-0402 Permit Type: BUILD RESID ADDITION CONTRACTOR INFORMATION Contractor Name: Business Name: Business Addr: City / State / Zip: REVIEWS AND COMMENTS Review Type DOCUMENTS MISSING 9/5/2017 Comment: 9/5/2017 Comment: DOCUMENTS MISSING Comment: FRONT COUNTER REVIEW Comment: PE REVIEW COMMENTS (2) Comment: 9/14/2017 Comment: 9/14/2017 Comment: 9/14/2017 REVIEW COMMENTS e1 Owner(s): Maria P Liteplo (Tr) / Merrill G Liteplo (Tr) Jurisdiction: SAINT LUCIE COUNTY Status Reviewed By INCOMPLETE Angela Huff NOTICE OF COMMENCEMENT FILLED LAND AFFIDAVIT COMPLETE Irvie Saunders COMPLETE Angela Huff Lot#: Block: Stories: Automatic Sprinkler System? No Fax Number: Email: Date Started Date Completed Date Released 8/21/2017 9/5/2017 9/5/2017 9/5/2017 8/21/2017 8/21/2017 8/2112017 INCOMPLETE William Durden 10/19/2017 SUBMITTED PLANS FOR THE TRUSSES ARE ALTERED WITH RED PEN, ANY CORRECTIONS TO THE TRUSS DRAWINGS SUBMITTED BY EAST COAST TRUSS MUST BE DONE BY THE ENGINEER OF THE TRUSS COMPANY. PLEASE SUBMIT REVISED TRUSS DRAWINGS IN DUPLICATE. PLEASE FURNISH TRUSS ENGINEERING CUT SHEETS IN DUPLICATE PER 107.2.1 OF THE 2014 FLORIDA BUILDING CODE WITH ORIGINAL SIGN/SEAL AS NO DIGITAL OR E STAMP/SIGNATURE WILL BE ACCEPTED. PLEASE NOTE THE SIGNATURE MUST BE IN PEN. PLEASE NOTE THAT THE CUT SHEETS PROVIDED HAVE AN ORIGINAL SEAL BUT THE SIGNATURE IS A COPY AND MUST BE ORIGINAUIN PEN FROM THE TRUSS ENGINEER SEPARATE PERMIT IS REQUIRED FOR THE SCREEN INFILL. PLEASE PROVIDE A DETAIL FOR THE SCREEN COMPONENT ATTACHMENT OR A SEPARATE SCREEN PERMIT WILL BE REQUIRED NO GAS SCHEMATIC SUBMITTED. PLEASE PROVIDE A GAS PIPING DETAIL INCLUDING BUT NOT LIMITED TO PIPE SIZE, REGULATOR, REQUIRED BTU'S FOR APPLIANCE OR A SEPARATE GAS PERMIT WILL BE REQUIRED '9-'zmc'� c I- ��Z' Planning & Development Services Building &Code Regulation Division. 2300 Virginia Avenue Fort Pierce, FL. 34982 Phone:(772)462.2172 Fax:(772)462-6443 9/14/2017 9/14/2017 10/19/2017 Comment: Comment: Comment: 10/19/2017 Comment: PLANS EXAMINER REVIEW Comment: REVIEW COMMENTS pnna 7 PLEASE NOTE THAT A SUBMITTAL CHECKLIST WILL BE REQUIRED STATING THE TYPE AND QUANTITY OF DOCUMENTS SUBMITTED FOR RE -REVIEW -SIGNED AND DATED BY THE CONTRACTOR PLEASE NOTE ANY COMMENT NOT ADDRESED MAY BE SUBJECT TO AN ADDITIONAL REVIEW FEE PER ST. LUCIE COUNTY RESOLUTION #13-196 SUBMITTED TRUSS ENGINEERING WAS SUBMITTED WITH A COPY OF THE SEAL AND SIGNATURE, PLEASE SEE SECTION 61G15-23.003 OF THE FLORIDA ADMINISTRATIVE CODE. ENGINEERING PLANS, SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS WHICH MUST BE SIGNED, DATED AND SEALED IN ACCORDANCE WITH THE PROVISIONS OF SECTION 471.025, F.S., AND RULE 61G15-23.001, F.A.C. MUST BE PHYSICALLY SIGNED, DATED AND SEALED AS PROVIDED HEREIN BY THE DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE. COMMENTS WERE SENT ON 10/19/2017 WILLIAM COMPLETE William Durden 9/14/2017 10/19/2017 10/19/2017 ,St-� cry Planning' Development S`e"rvices: 'Building8; Code Regulation 6141sion- 2300 Virginia -Avenue. FortPlerce, FL. 34982 Phone:(7Z2)462-2172 Fax:(772)462-6443 PROPERTY INFORMATION Address: 2016 Laurel Oak Ln City / State / Zip: Palm City., FI 34990 Parcel M 4425-605-0041-000/3 Zoning: PUD APPLICATION INFORMATION Permit Number: 1708-0402 Permit Type: BUILD RESID ADDITION CONTRACTOR INFORMATION Contractor Name: Business Name: Business Addr: City / State / Zip: REVIEWS AND COMMENTS REVIEW COMMENTS Page 1 Owner(s): Maria P Liteplo (Tr) / Merrill G Liteplo (Tr) Jurisdiction: SAINT LUCIE COUNTY Lot#: Block: Stories: Automatic Sprinkler System? No Fax Number: Email: ReviewTyoe Status Reviewed By Date Started Date Completed Date Released DOCUMENTS MISSING INCOMPLETE Angela Huff 9/5/2017 Comment: NOTICE OF COMMENCEMENT 9/5/2017 Comment: FILLED LAND AFFIDAVIT DOCUMENTS MISSING COMPLETE Irvie Saunders 9/5/2017 9/5/2017 9/5/2017 Comment: FRONT COUNTER REVIEW Comment: PLANS EXAMINER REVIEW Comment: 9/14/2017 Comment: 9/14/2017 9/14/2017 Comment: 9/14/2017 Comment: 9/14/2017 Comment: COMPLETE Angela Huff 8/21/2017 8121/2017 8/21/2017 INCOMPLETE Gfa-Engineer 9/14/2017 PLEASE FURNISH TRUSS ENGINEERING CUT SHEETS IN DUPLICATE PER7107.2.1 OF THE 2014 FLORIDA BUILDING CODE WITH ORIGINAL SIGN/SEAL AS NO DIGITAL OR E STAMP/SIGNATURE WILL BE ACCEPTED. PLEASE NOTE THE SIGNATURE MUST BE IN PEN. PLEASE NOTE THAT THE CUT SHEETS PROVIDED HAVE AN ORIGINAL SEAL BUT THE SIGNATURE IS A COPY AND MUST BE ORIGINALIIN PEN FROM THE TRUSS ENGINEER PLEASE PROVIDE IN DUPLICATE A DUCT PLAN IN DUPLICATE SHOWING A BALANCED SYSTEM, DUCT SIZE, GRILL SIZE, AND ROOM BY ROOM COOLING CFMS FOR THE NEW CONDITIONED SPACE PER 107.2.1 OF THE 2014 FLORIDA BUILDING CODE CORRESPONDING WITH THE MANUAL J PROVIDED. THE COOLING CFM'S MUST BE WITHIN 10% OF EACHOTHER PER 107.2.1 OF THE 2014 FLORIDA BUILDING -CODE. PLEASE PROVIDE A DETAIL FOR THE SCREEN COMPONENT ATTACHMENT OR A SEPARATE SCREEN PERMIT WILL BE REQUIRED PLEASE SHOW ON PLANS SOIL DENSITY BY PROCTOR. SEE SECTION 1803 OF THE 2014 FBC. IF NOT PROVIDED A FULL GEOTECHNICAL WITH A SUMMARY CONCLUSION WILL BE REQUIRED. PLEASE PROVIDE A GAS PIPING DETAIL INCLUDING BUT NOT LIMITED TO PIPE SIZE, REGULATOR, REQUIRED BTU'S FOR APPLIANCE OR A SEPARATE GAS PERMIT WILL BE REQUIRED Planning & Development Services Building & Code Regulatidn,I)M§ion 2300 Virginia Avenue Fort Pierce, FL. 34982 Phone:(772)462-2172 Fax:(772)462-6.443 REVIEW COMMENTS e2 Comment: PLEASE NOTE THAT THE COMMENTS ARE FOR THE CLARIFICATION OR CORRECTION OF THE SUBMITTED DOCUMENTS. ADDITIONAL REVIEW MAY BE REQUIRED AFTER SUBMITTING CORRECTED DOCUMENTS. PLEASE NOTE: (1) ALL REVIEW COMMENTS WHEN ANSWERED WILL REQUIRE A COVER LETTER 9/14/2017 ADDRESSING WHERE THE CHANGES WERE MADE, (2) ALL CHANGES WILL BE REQUIRED TO BE CLOUDED ON THE PLANS AND (3) THE CONTRACTOR WHEN RESUBMITTING WILL BE REQUIRED TO INSERT THE NEW UPDATED PAGES INTO THE PLANS OR IF THE CONTRACTOR PREFERS, A REVISED COMPLETE SET OF PLANS CAN BE SUBMITTED Comment: PLEASE NOTE THAT A SUBMITTAL CHECKLIST WILL BE REQUIRED STATING THE TYPE AND QUANTITY OF 9/14/2017 DOCUMENTS SUBMITTED FOR RE -REVIEW SIGNED AND DATED BY THE CONTRACTOR Comment: PLEASE NOTE ANY COMMENT NOT ADDRESED MAY BE SUBJECT TO AN ADDITIONAL REVIEW FEE PER ST. 9/14/2017 LUCIE COUNTY RESOLUTION #13-196 9/1412017 Comment: COMMENTS SENT 9/14/17